HomeMy WebLinkAboutSewagei STATE OF FLORIDA /e 4 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Standard Pacific Of Florida GP, Inc AGENT: The Milcor Group, Inc. PROPERTY ADDRESS: 3116 NW Radcliffe Way Palm City, FL 34990 LOT: 23 BLOCK: 0 APPLICATION #-AP611275 PERMIT # : 56-S F-661095 DOCUMENT # : FI 1131934 DATE PAID:07/07/2016 FEE PAID :400.00 RECEIPT #:56-PID-3000283 SUBDIVISION: Riverbend ID# : 4426-703-0028-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1050.00 [21 483.00 [ ] [27] SURFACE WATER 100 FT I ] [021 TANK MATERIAL Concrete [ ] [281 DITCHES 27 FT [ ] (031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] (30] 'PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 28-015-08DC3 2. 70-143-54SC4 [ ] [321 POTABLE WATER 20 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 5 FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 15 FT . [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [-101 AREA [11 679.2 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] .[381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 09/01/2017 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] 1161 ELEVATION [ A80VE / BELOW ]BM 15.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431. MAINTENANCE AGREEMENT I ] [201 AGGREGATE EXCESSIVE FINES [ ] 1441 BUILDING AREA [ ] 1213 AGGREGATE DEPTH [ ] [451 'LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR Brian Davis (Brian Davis Sept [ ] [221 FILL AMOUNT [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [23] FILL TEXTURE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ]" 1261 REPLACEMENT MATERIAL [ ] [50]' TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / . St. Lucie CHD DATE; 05/12/2017 DISAPPROVED ) ' Envir ental Specialist II Br ngram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: Lucie CHD DATE: 09/01/2017 Environmental Specialist II Brian ngram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP611275 EI0661095 — APPLICATION # : AP611275 STATE OF FLORIDA PERMIT #:56-SF-661095 DEPARTMENT OF HEALTH DOCUMENT #:FI113.1934 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM' CONSTRUCTION INSPECTION .AND FINAL APPROVAL, DATE PAID:07/07/2016 •�WEFEE PAID:400.00 RECEIPT #:56-PI,D-3000283 Violation Number Comment comments . The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of 520 gpd. 1050 and 483 STs in series. 540 gal DT (70-143-54SC4). Liberty 1/3hp pump. 4x15 long. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system and alarm check. No violations, final. system approved. Contractor, building department and builder emailed final approval. DH 4016, 08/09 (Obsoletea•all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP611275 EID661095 .Page 2 .of 3