HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gauge Client: Project: Report Date: 10112/2016 Standard Pacific Homes, South Florida 13-0183.00 38 Test Method: ASTIVI 1) 6938 825 Coral Ridge Drive Riverbend Coral Springs, FL 330714180 St. Lucie County, Florida Port St Lucie FBPE CA 94930 521 NW Enterprise Drive Port St. Lucie. FL 34986 Phone. 772-924-3575 1,Fax-. 772-924-3580 4q A" Optimum Maximum In Place In Place Probe Mln[Max Retest Test Soil Moisture Dry Density;, Moisture Dry Density Depth Percent Comp. Test# Of Date ProctorlD Method Classification (%) (Pcf) (Pcf) (in) Compaction (0/6) Remark 102 10/11/16 P-1 NIA 10.2 116.0 7.6 114.4 12 99 95/'105 Pass 103 10/11/16 P-1 NIA 10.2 116.0 10.3 112.9 12 97 95/105 Pass, 164 1 10/11/16 P-1 NIA 1 10.2 1 116-,0 7.8 1 114.0 12 98 95/105, Pass A.i W Y 4 Gauge Test # test Location Elevation Reference Make I Model I SN Field Technician 102 Below Slab Grade: Lot 23, Foundation Undalion Pad, Oenter 0-1 Troxler 3430 25093, Balker, Jeff — 103, Below -Slab -Slab qradd::Lof 23; FoundationPad, Southwest 0;11 Troxler 3430 25093 Baker, Jeff laxt Below Slab Grade: Lot 23,foundation,Pad, Northeast Troxler 3430 25093 Baker, Jeff Comments,,-,S. 4 "C" t Pass: Tests: results comply-wjth'speclfications ]"Backsiatter. T6stdare"DirbttTransrhission'(Methed A).unless ptohe deptl) Is noted as Gauge calibration data on file with the testing agency. C; E N 0675 0 10/1 2/tO� (E &;Wd Wsmae P(W. j 4U AN P - W r6fek Test Reports shall not, be reproduc6d.'except in fulf, Without the written approval Of GFA International Inc. Page �1?'Of I Digitally -signed printed copies of this document are not considered signed and seated and the signature must be verified on any electronic copies.