HomeMy WebLinkAboutPOOL SPECIFICATIONSPools by Greg, Inc. wants you to know: A barrier or alarm is not a substitute ! Instruct baby-sitters about potential pool hazards to young children and about the use of protective devices such as door alarms and latches. Emphasize the need for constant supervision. for parental supervision. No .child should be left unattended. Parents should During social gatherings at or near a pool appoint a "designated water" to protect young children from pool accidents. Aduits make take turns being the watcher otherwise, adults may become preoccupied and assume someone else is watching the children. know that the only way to prevent an accident is with adult supervision. ! If a child is missing, check the pool first. Seconds counting preventing death or disability. Go to the edge of the pool and scan the entire pool bottom and surface as well as the pool area. They should maintain constant eye contact with children whenever they are u) Do not allow a young child in the pool without an adult. near, or could get near any body of water. Unfortunately, most accidents -J r Do not consider young children to be drown proof because they have had swimming lessons or are wearing a life jacket. occur when there is a lapse in supervision, even for a small time. © r Learn CPR (cardiopulmonary resuscitation) baby sitters and other caretakers such as grand parents and other siblings should also know CPR. Nevertheless, parents should be aware that nay body of water poses a risk, L0L Keep rescue equipment by the pool. Be sure a telephone is pools side with emergency numbers posted nearby especially for children under 5 years of age. Pools by Greg, Inc. cannot be r Remove toys from in and around the pool when not €n use. Toys can attract young children to the pool. held responsible for any lossi damage, death or injury due to malfunction or ! Never prop open the gate to a pool, failure of barrier or alarm when used by the customer, for any reason LL No running, pushing, wresting or disturbance In the pool area. No chewing gum permitted in the pool (Red Cross safety suggestion for the prevention of chocking). beyond its control under any circumstances, for any reason whatsoever. N r Don't let long hair get near pool outlet. The suction can cause hair or body entrapment and drowning. The customer assumes all risk directly and indirectly related to W ! Have a first aid kit at pool side. malfunctioning or failure of barrier or alarm. fools by Greg, Inc. makes no Never swim alone. claim whatsoever to the difference of these policies, r No jumping or diving in the shallow area of the pool. Don't allow children to play as though they are drowning - a false alarm might delay a rescue in the event of a real emergency. ! When diving, always enter the water with your arms extended firmly overhead and keep your hands together to protect your head. Diving into shallow water can result in cervical spine injuries causing permanent paralysis. Never dive into an above -ground pool r Avoid the use of alcohol or other drugs around the water. r ! i ,h I 45.5 ljr� Ili ��!! j'1 tF; U' o Vac Line .41 ' I . l �nr . ; r ag Ali i�1 �r .IRI, I Yk 1 > till F • i i � �, � �'��� r� �Ij Ir;, . Iz � II iir r �I 0 I, r �,� � u��t \. ' ;'� a it S ��P : � 7►�j�r, yf IF 44� I rt rjle �; ;r't T 1r`I;' E,! � l��i121 1" 14, Milo 41 g1 q,1� Main drain a0 ,I{�r F iI 1i tI ii �::rl'Il±! 6' deep = 3' 6 deep w R 1 4811_ Tail Elie v - - - - - - : - .�-�.. _ �.� Overflow for skimmer child protective o\o� Skimmer barrier per FL _ c� code .. .......................... ..........................:.................�.----.--.-............................-----------..-.....-.....-......-----.......................-------------------......... 45 Return Line ,I d, 711 I ��- Deck-o-drain LO l PLAN DATA `. Pool 15' 6" x ao, SF 374.20 LF 77' s" Patio 623,59 s.F. Spa Commenis SF LF WWZAar!ld��r%N YFAIIm I €0dWW7A\1117�19I®iv§MWXWA'yp1 MLlPlp M WE 01 R►vARHP tR&V LWI Rear -of home Future valve for heater Digitally signed by Marvin R Marvin RDN: Rodgers c=US, o=Unaffiliated, ou=A01410C000001725DB6E2C A0001 n RO d g e" s Rodgers Date 021912 012052 22 05'00' POOL -SPECIFICATIONS Max width 15, B Max length 30' Min depth 3' 6 Max depth 6' Shape FREEFORM Elevation Dirt from excavation haul' Leave Leave & spread X Leave -move -then spread Extra fill & compaction Jab entrance ON LEFT OF HOME Tile See color sheet Int. Finish See color sheet Step tile See color selection sheet Filter C&C100 Pump PENTAIR Motor H.P. 1.5HP / VS Time clack INCLUDED J Box INCLUDED Light (1) GLOBRITE _Transformer INCLUDED Main drain INCLUDED Skimmer INCLUDED Inlets (3) INCLUDED Therapy N/A Swim o or ladder N/A Handrail NIA Heater NIA Tank Vac head INCLUDED Vac hose INCLUDED Vac pole INCLUDED Brush INCLUDED Leaf skimmer INCLUDED Test kit INCLUDED Chlorinator IC-30 - SALT Fill line Overflow line INCLUDED Pool cleaner/stub Water & electric supply H.O WILL PROVIDE Screen enClasi.tre TBD Footers INC. Electrical hookup PAYUK ELECTRIC Patio 26' 5"x45' S" Color See color sheet Existing patio 358.35 Si" - Texture/Paint existing Planters NIA Deco drain INCLUDED FT 45' 5" Approx. gallons 10 B87 Pump G.P.M. Approx. turnover time Hr. Min. Safety Fence color BLACK Solar by NIA Yes -No Brick X 2x6 X 6x6 X Sheet Tile X Overpour X Mosaics X Future valve for heating w/ slab Texture existing patio +/-360 SF OWNERS HERBY ASSUME & AGREE TO THE PROVISIONS OF THE CONTRACT FOR POOL CONSTRUCTION AND APPROVE THESE PLANS WHICH ARE MADE PART OF THE CONTRACT, HOMEOWNERS ASSOCIATION REQUIREMENTS AND APPROVAL SHALL BE THE RESPONSIBILITY OF THE OWNER. OWNER / AGENT SIGNATURES: X DATE rG: CPC1458338 Swimming pool for: Benjamin Taylor & Heather Phillips 10700 Carlton Road Saint Lucie County, FL (772) 203-8297 Drawn by: Justin Sapp —Pool construction complies with FBC 2020, ANSI-7, ANSI-15 —Water Velocity —Max 8ft/sec as per FBC 2020—R4501.6.3 —Pool Barrier to comply with Section R4501.17-7th edition FBC —Skimmers comply with FBC 2020—R4501.21.2 —Soil bearing capacity assumed 2,000psi @95% compaction —Equipment Foundation 3'x7' conc. slab min 3.5" thick pour in place or approved Hurricane Rated precast equipment pads WHEN PROVIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCALE) PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION 0 N Vacuum (In Hg) X 1.13 Feet Of Head HYDRO -STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TO GRAVEL BED MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER - 4" THICK WALLS W/#3 REBAR @12' O.C. EACH WAY 3' TO 6' - 6" THICK WALLS W/#3 REBAR 012" O.C. EACH WAY 0' TO 3' - 8" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 9 ft. J J MISC. NOTES 6 ft. J 0: 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL 0 WATERLINE Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head #8 COPPER qTO HORIZONTAL INSTALL #8 COPPER TO GRID VERTICAL INSTALL PoolBond PB-2008 Install in Plumbing T at least 3" Below Water level in Return Piping.lnstall in sprinkler box for easy access WATER BOND DETAILS FOR NICHLESS LIGHT SYSTEM EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: * SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE Q� SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO x - a Z 0 0 0 rn N 4 ° o L` <� << a N d ' IL o w d. 10" MIN(TYP) ° STEP DETAILS 1. TREAD IS MIN OF 10" WIDE. 2. BOTTOM & TOP RISERS MAY VARY IN HEIGHT 3. RISER NOT GREATER THAN 12" EXCEPT BOTTOM STEP WHERE DEPTH IS 4' OR GREATER 4. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. C4 min it cY (NO SCALE) NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP OVERPOUR LINE WHEN EMPTYING POOL WHERE 6"x GRATE SHALL BE SECURED IN IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL TRENCH DRAIN TREADED PLUG Ya" PER FT. MIN SLOPE OR CAP TILE 6" TILE 4" SLAB TERIOR 2500 FIBER MIX FINISH 4y" TYP. WALL-3,000 PSI GUNITE 8" •'• STEEL-TEX FORM OR KRAFT WALL 6" TYP. FLOOR 3,000 PSI #3 @ 12" O.C.B.W. Q " GUNITE NOTE: FOR DEPTHS C� 4; GREATER THAN 6' ADD (1)#3 COVE BAR @6" O.C. GRAVEL BED- TO PUMP - TYP. WALL SECTION & WELL POINT (NO SCALE) WATER LEVEL UNDERWATER LIGHT POOL LIGHT JUCTION BOX z POOL PATIO 12 VAC FROM 75 POWER SUPPLY SIZE AS DETERMINED BY LICENSED ELECTRICIAN YARD BY EQUIPMENT POOL FINISH 1" PVC ,. SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) (2) #3 REBAR OR (1) #5 REBAR FOOTER DETAIL CHPNNE� ��N (NO SCALE) PIPING SCHEMATIC HAIR & 11NER CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL OUTLET CMP 25506-32X VGB PER FRC4501.6.6 COMPLIANT 32" CHANNEL DRAIN COMPLIANT WITH 2020 FLORIDA BUILDING CODE LISTED TO ASME/ANSI A112.19.8 Lj Li 32" CHANNEL DRAIN AND SUMP 2e� 25506-320-000 *THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing. DECK LEVEL FLOOR 5'—V POOLS�I' by GREGNC 1 ROW OF WATERLINE TILE WATERLINE - MAX s' - Q" LIGHT -I I #3 STEEL @ 12" O/C E.W. - �_ 6" THICK -7 FLOOR SLOPES FLOOR SLOPE SHALL BE REASONABLY UNIFORM AND COMPLY5.6.3WffH ARTICLES 5.6.1 THRU THE SLOPE OF THE FLOOR FROM THE SHALOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 4'-0" JV —V TYPICAL SECTION THRU POOL (NO SCALE) Pipe Size 6 fps 8f ps 1" 16 gpm 0.14' 21 gpm 0,23' 1.5" 37 gpm 0,08' 50 m 0.14' 2" 62 gpm 0.06' 82 gpm 0,10' 2,5" 88 gpm 0.05' 117 gpm 0.09' 3" 136 gpm 0.04' 181 gpm 0.07' 4" 234 gpm 0.03' 313 gpm 0,05' 6" 534 gpm 0.02' 1 712 gpm 0,03' WALLS SHALL NOT SLOPE GREATER THAN 11" Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: —_—XXX ___ft_XXX_x 7.48(gal/Ft) = —_—XXX ___gal (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: XXX _ _ al XXX = XXX___+__ XXX _ __ _ _XXX (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be_ 2 __inch to keep velocity @ 8 fps max. at—AZ--gpm Maximum System Flow Rate. Return Piping to be 2 --inch to keep velocity @ 8 fps max. at_ 82--gpm Maximum System Flow Rate. Main Drain Cover(__—__ SEE _ABOVE ---) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR SUPERFLO VS H.P. 1.5 Total H.P.=H.P.x service factor.1 H.p. or more must be 2 speed or variable speed Filter Make PENTAIR C&C Size 100 Filter min. area based on 6hr. turnover flow rate pool gal. / 360 min. = Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make ON PUMP Model ------ Controls must operate a minimum of two speeds. The hiaher soeed override is not to exceed one normal cvcle or 24 hrs. whichever is less DESIGNED FOR: POOLS BY GREG TAYLOR/PHILLIPS RESIDENCE 10700 CARLTON RD ST LUCIE COUNTY, FL M. RANDALL RODGERS, P.E. FL License No.68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** PREPARED BY: SHEET: STEVE HORST 2 DRAFTING & DESIGN SERVICES 3 (772)201-7846 horst.steve@yahoo.com PENTAIR TDH CALCULATOR PBG-TAYLOR/PHILLIPS-HIG STEP 1 POOL SPECIFICATIONS STEP 2 SELECT EQUIPMENT TON CALCULATION STEP 3 OF 3: TDH CALCULATION Pool Specifications Pool Volume(gallons): 10687.00 gallons Suction Lift: 1.50ft Turn Over (hours): 6.00 hours Filtration Flow Rate: 36.00 GPM Maximum Flow Rate 67.60 GPM Selected Components Components SELECTION QUANTITY MAXIMUM PIPEVELOCITY(FUSECI IConsuLTYOUR LOCAL CODE) SUCTION OUTLET B • MAIN DRAIN 1 TOTAL PIPING LENGTHS IFTI DISCHARGE B INLET 50.00 DISCHARGE 120.00 ❑� 1/2INCH RETURN SELECTION 3 QUANTITY 90 DEGREE ELBOW INLET 6 NO IMAGE AVAILABLE DISCHARGE 12 ICHLOR 30 1 TEE THROUGH INLET O DISCHARGE 4 1.5"X2"SWAY VALVE 2 CLEAN AND CLEAR 1 SELECTION / MODEL QUANTITY SUPERFLO VS 1 Results: Your TDH Calculation Flow Rate 67.60 GAL/MIN Max Flow Rate at Max RPM: 67.60 GAL/MIN Head Loss 52.36 FT Head Loss at Max Flow Rate at Max RPM: 52.36 FT REQUIRED MINIMUM PIPE SIZE Inlet Piping: 2.00 Discharge Piping: 2.00 PUMP RPM Flow Rate at Selected Pump RPM: 67.60 Pump RPM: 3450 J Head Loss at Selected Pump RPM: 52.36 SYSTEM HEAD PRESSURE CURVE BY PUMP SELECTION 120 110 100 PC 90 T " so � F U m m 70 v m 60 m 3 `a 'm .. SO a 0 9 V tl 40 'w z 30 3 0 0 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Volumetric Flow Rate (GPM) -Clean System Curve -Pump Curve I Desired Operation Point - Clean System 1 Pump Operation Paint v1�PSP The & Spa Professionals' PBG-TAYLOR/PHILLIPS-LOW ANSVAPSPACC 15a ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS PRO1ECr NAME: AND ADDRESS TAYLOR/PHILLIPS COMRACTOR NAME AND ADDRESS: POOL BY GREG OWNER: CONTRACTOR PHONE: DATE: 12-1-21 „i.,uuuu ivn nm5 wmnnuee m Lne weooauon or roo. ana spa Professionals (APSP1. It is not part of the American National Standard ANSI/APSP/ICC-1Sa 2011 but is included for information only. Contractors should acquire and comply with the ANSI/APSP/ICC-15a 2011 standard which ran be purchased at www.ap'li-mg. 1. §5.2.1: Calculated pool volume a. Gallons: 10,687 ; or 1. 10,687 gallons - b. Calculated Gallons: (surface area) X (average depth) X Z48 (gai/f A3) _ 2. §5.2.1: Calculated filtration flow rate 2. 36 gpm _ (Pool volume : 360 or 36gpm whichever is larger) 3. §5.5.1: Pipe sizing: a. Minimum suction pipe diameter 31. 1.5 inches - (Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than item 2.) b. Minimum suction branch pipe diameter 3b. N/A inches (Calculate: Item 2. (gpm)-Branch Pipes _(quantity) = branchflow rate (gpm). _ Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated suction branch flow rate.) c. Minimum return pipe diameter 3c. 1.5 inches (Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than item 2.) - d. Minimum return branch pipe diameter 3d. N/A inches (Calculate: Item 2. (gpm)-Branch Pipes_(quantity)=bronchflowrote (gpm). Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated return branch flow rate.) 4. §5.4.1: Filter type and size: a. Filter type: (Cartridge, DE, Sand) 4a. CART b. Minimum filter area 4b. 96 sq. ft. - (Calculate: item 2. (gpm) -filter factor_ (glDm/f -2)) F'lter factors: Cartridge=0.375, 5and=15, Diatomaceous Earth=2 5. §5A.2: Backwash valve: X No? N/A _Yes, (When using a backwash valve, enter result of item 3c or 2 inches whichever is larger) S. inches - Table 1 Iwheo u:<el Pipe Size: t- 2" 2.5" 3" 3.5" 4' 5" 6" Nominal GPM 1116 fps 38 fi3 90 138 185 238 374 540 Nominal GPM e 6 fps 1 51 64 1 119 1 184 1 247 1 317 499 720 6. Single -speed pump selection (when used): §5.1.1, 5.3.1: For single -speed pumps with a total horsepower0.99 or less, find and enter a compliant pump from the Pool Pump Database. a. Pump model b. Total horsepower 7. Multi -speed pump selection (when used): §5.3.2.1: Pools 17,000 gallons or lest' select pump from the database with a Curve -A gpm flow equal to item 2 ar less. §5.3.2.2: Foals 17,001 gallons or more, select pump' from the database with a Curve-C gpm flow equal to item 2 or less. 'Multi -speed pumps must have one speed listed that satisfies this requirement. a. Pump model b.Pump flow (§5.3.2.1, 5.3.21: Applicable Curve A or Cgpm flow listed in database) 6a. N/A 6b. N/A or PENTAIR SUPERFLO VS 7a. 7b. 45 gpm 3/17/15 ANSI/APSP/ICC-1S Standard Writing Committee Form 1 of 2 INSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS Component Section Requirements Check 4.4.1.1 Heater has no pilot light 4.4.1.2 Readily accessible on -off switch mounted outside of the he N/A Heaters 4.3.1.3 pa with tight fitting cover with R-6 insulation, No electric resistance heating u �healjnng�frorn or for pool with 6 Ocumented pon-site solar or recovered energy. 4. Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 5.1.1 Pool filter pump listed in database X 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi -speed X Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary 5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for X servicing. 5.3.4 Single -speed pump controller capable of operating pump during off-peak electric demand. N/A Pool systems 5.5.2 Pipe before pump has at least 4 diameters of straight pipe. X System installed with solar, or setup for the future addition of solar heating equipment by 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or X built-up connections, or dedicated pipe to and from the pool. 5.6 Directional inlets for mixing pool water. X 3/17/15 ANSI/APSP/ICC- 15 Standard Writing Committee Form 2 of w 325 Ea E W py�ad omQ3�� W Ft0 W cW cw o� E. O Couj o_ W ca N vI 3 cn 9 r>0 .Zaa ace �zmR�o ZO .7 3� QU �U] ,ZR7 3 o it o 0 o z U d FA th W 't O z Enama U N Tr1. z z 01 F GO GO E O�q W Z dz W WU O 3 P0 W a Pill ii N moo O I zo pOi o � \III/ W t2 o Fh F-m v o 0 0 En 7.0 z a� w� �o ��WO '+E ro- TD3 o co z p.�; U m rn ti O - V O O dIi p6 Oa zd �mPAM t` �ce z �a C U O LL F � Paz w o o a s. ta7tj AAC � �V a0 12. WF t9 >m00 a12 W zz �+ a W O 11�i low 00 fszW}7�7y-+�IM m M a Eli m¢m N N CEO. mO_ Crti o 0o W 1 N to E i �0 r0z W oo W o a°a` C3 P4 O N pT W U W z 1/2' SHEET METAL SCREW 13/' X Wr' TAP CON HEATER 2' GALVANIZED ANGLE BRACKET OR PUMP/FILTER FRAME (TYP) [43/2' rein, THICK CONCRETE SLAB d HEATER FILTER d POOL EQUIPMENT ANCHOR DETAIL