HomeMy WebLinkAboutPermit Worksheets 1-20-22PERMIT WORKSHEET page 1 of 2 PERMIT NUMBER Installer 4 Lei Installer Mobile Phone Address of home being installed Manufacturer /� • License # _TA CD Length xwidth 6e5 NOTE: If home is a single wide rill out one half of the blocking plan if home Is a triple or quad wide sketch /n remainder of home I understand Lateral Arm Systems cannot be used on any home (new or used) where the sidewall ties exceed 5 ft 4 in. Installer's initials Typical pier spacing 7 ' / i / I lateral � rr - V r 1—_ --, Show longitudinal locations of Longitudinal and Lateral Systems (use dark lines to show these locations) I 171 y t - t LLL111 J ..... I martiage wall piers within 2' of end of home per Rule 15C ch i ,h. ===H Hj F] ba / r 7 ................. ................r.............._............._ ..... .. ................,........_...... I I ,..... i .....t.............. i E........i....i....a.... i...........l.................................... ..... ..... ...i .. ...........i..... ...j..... ..... . �....-i--•- .:................. - - ... E .._.t.... ........_ .....i.... ...... ....._....... .... ..... ......... .I.... ...... i r---..........{I..................:.............._..._ r ` ..._.....�.... I .... ....:...4.... ..' ....•. ........................_ _ .................. '. ..........I-----'---- ..... ......... ..... E.... i ..... 1..... . ......._ ........ I ...;..... ..... . .... t.... s.... ..... 7. -_--...�..•..........._..... ;_... . �.....}_.._ ..... .. .........' ..... .. I (...... i.....s. ��.. .... i i ....................... I......_}..._Q....iti.i . 3 ...... ........ .�. .. I .... •......•. ,. i.. ............................. ...._..i :................ i ... ...... .. ...1.... a..... ......_ _....... . I i ..j.....I ..................... �................... i j.... . I... t ` �..........i i I I l !...........} New Home ❑ Used Home Home Installed to the Manufacturer's Installation Manual ❑ Home Is Installed in accordance with Rule 15-C ❑ Single wide ❑ Wind Zone II ❑ , Wind Zone III Double wide er Installation Decal # logo> S / % S.S Triple/Quad ❑ Serial # J_AC F120 39 /,A_ Roof System:--,4/—Typical Hinged 8 PIER SPACING TABLE FOR USED HOMES Load bearing capacity Footer (sq siza 16" x 16" (256) 181/2" x 18 1/2" (342) 20" x 20" (400) 22" x 22" (484)` 24" X 24" (576)• 26" x 26" (676) 11 ' , �I 8 , g g ! ! r 8 interpoiatea trom Kwe 1bG-1 pier spacing taDle. PIER PAD SIZES I-beam pier pad size / -'W7 Z'� Perimeter pier pad size i I rz Z'' Other pier pad sizes (required by the mfg.) 1.u.ji Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pad ize Sg In iti x lb 16 x 18.5 x 18.5 x 13 114 x 26 1 348 20 x 20 400 x 3 1 x 1—Tr6- 1 24 x 6 26 x 25 6 6 ANCHORS 04ft 5ft FRAME TIES within 2' of end of home spaced at 5' 4" oc OTHER TIES Number / Longitudinal Stabilizing Device (LSD) Sidewall ✓ Manufacturer Sk.T_+_j4 Longitudinal Longitudinal Stabilizing Pevice w/Latefal Arms Marriage wall Manufacturer �ylipLv_�ra�+�� sy5-yShearwall Pier pad size Z 2' Imo.• �'''�i' � Z'' TIEDOWN COMPONENTS • PERMIT WORKSHEET ae2of2 PERMIT NUMBER POCKET PENETROMETER TEST The pocket penetrometer tests are rounded own to psf or check here to declare 1000 lb. soll without testing. X X X POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footer. 3. Using 500 lb. increments, take the lowest reading and round down to that increment. X X X TORQUE PROBE TEST The results of the torque probe test Is . Z8' inch pounds or check here If you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4000 lb (ding capacity. ,R Installer's initials ALL TESTS MUST E PERFORMED BY A LICENSED INSTALLER Installer Name Date Tested Electrical Connect electrical conductors between multi -wide units, but not to the mainpywer source. This includes the bonding wire between mult-wide units. Pg. Plumbing Connect all sewer drains to an existing sewer tap or septic tank. Pg. Site Preparation Debris and organic material removed / Water drainage: Natural Swale Padv Other Fastening multi wide units d 0' Floor; Type Fastener: �p1� Length: 8 Spacing: t Walls: Type Fastener: Length: g N Spacing: /Z'� Roof: Type Fastener: Length. Spacing: / Z For used homes a . 30 gauge, 8" wide, galvanized metal strip will be centered over the peak of the roof and fastened with gaiv. roofing nails at 2" on center on both'sides of the centerline. GaSket (waatherorooflna roaulromeMl I understand a properly Installed gasket Is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials Type g� �s,ek�t,� Installed: � Pg. -' Between Floors Yes 61 Between Walls Yes V Bottom of ridgebeam Yes Weatherproofing The bottomboard will be repaired and/or taped. Yes _ —1 Pg. Siding on units is installed to manufacturer's specifications. Yes L1— Fireplace chimney installed so as not to allow intrusion of rain water. Yes Miscellaneous Skirting to be Installed. Yes No Dryer vent installed outside of skirting. Yes N/A Range downflow vent installed outside of skirting. Yes .L/ N/A Drain lines supported at 4 foot intervals. Yeses Electrical crossovers protected. Yes �k::f Other: Installer verifies all information given with this permit worksheet is accurate and true baseo on the manufacturer's Installation InstrmctIQWand or Rule 15C-1 & 2 Connect all potable water supply piping to an exdting water meter, water tap, or other Installer Signature ® Date 1D -�Z-7'2/ independent water supply systems. Pg. L/ �- -wor0-'