Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL30343-R2
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Premier Metal
Address/Phone/Email 17613 South Hwy. 475
Summerfield, FL 34491
(352) 356-1609
flvalidation@yahoo.com
Authorized Signature Ray Bowen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
David Eng
Florida License PE-81377
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 08/03/2022
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL30343_R2_COI_26ga_5VCrimp_plywood.pdf
Referenced Standard and Year (of Standard)Standard Year
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
1/10/22, 2:08 PM Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCYkVDshJc8dKAmGMcj5Xf7q3obLlgxVr3Q%3d%3d 2/3
Product Approval Method Method 1 Option D
Date Submitted 10/21/2020
Date Validated 10/25/2020
Date Pending FBC Approval
Date Approved 10/28/2020
Summary of Products
FL #Model, Number or Name Description
30343.1 01: 26ga 5V Crimp over plywood 26ga (min) 5V Crimp over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: 108.5psf with 12"-12" pattern at 12"oc
Installation Instructions
FL30343_R2_II_26ga_5VCrimp_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_26ga_5VCrimp_plywood.pdf
Created by Independent Third Party: Yes
30343.2 02: 26ga PermaShield over plywood 26ga (min) PermaShield screw strip over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116
Other: 116psf fastener every hole WITH sealant, 71psf
fastener every other hole
Installation Instructions
FL30343_R2_II_26ga_PermaShield_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_26ga_PermaShield_plywood.pdf
Created by Independent Third Party: Yes
30343.3 03: 032 Aluminum PermaShield over
plywood
Nominally 032 or thicker aluminum PermaShield screw strip
over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-153.5
Other: 153.5 with fastener every hole WITH sealant, 86psf
with fastener every hole with OUT sealant.
Installation Instructions
FL30343_R2_II_032Al_PermaShield_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_032Al_PermaShield_plywood.pdf
Created by Independent Third Party: Yes
30343.4 04: 26ga TuffRib over plywood 26ga (min) TuffRib over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5
Other: 123.5psf with 6.5"-2.5"-6.5"-2.5" fastener pattern @
12" oc, 82.25psf with 9"-9"-9" fastener pattern @ 24" oc
Installation Instructions
FL30343_R2_II_26ga_TuffRib_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_26ga_TuffRib_plywood.pdf
Created by Independent Third Party: Yes
30343.5 05: 032 Aluminum DuraSeam over
plywood
Nominally 0.032" or thicker aluminum DuraSeam over 15/32"
(min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: 108.5 psf with clips @ 18" oc
Installation Instructions
FL30343_R2_II_032Al_DuraSeam_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_032Al_DuraSeam_plywood.pdf
Created by Independent Third Party: Yes
30343.6 06: 26ga DuraSeam over plywood 26ga (min) DuraSeam over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5
Other: 93.5psf with clips @ 12" oc, 63.5psf with clips @ 16"
oc
Installation Instructions
FL30343_R2_II_26ga_DuraSeam_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_26ga_DuraSeam_plywood.pdf
Created by Independent Third Party: Yes
30343.7 07: 29ga TuffRib over plywood 29ga (min) TuffRib over 15/32" (min) plywood | Fastener in the
rib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5
Installation Instructions
FL30343_R2_II_29ga_TuffRib_Plywood-rib.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
1/10/22, 2:08 PM Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCYkVDshJc8dKAmGMcj5Xf7q3obLlgxVr3Q%3d%3d 3/3
Other: 123.5 psf with 9"-9"-9" fastener pattern @ 12" oc,
56psf @ 24" oc
FL30343_R2_AE_29ga_TuffRib_Plywood-rib.pdf
Created by Independent Third Party: Yes
30343.8 08: 29ga TuffRib on 1x4 battens over
plywood
29ga (min) TuffRib on 1x4 (nom) battens over 15/32" (min)
plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131
Other: 131 psf with 9"-9"-9" fastener pattern @ 12" oc,
78.5psf @ 24" oc
Installation Instructions
FL30343_R2_II_29ga_TuffRib_1X4.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_29ga_TuffRib_1X4.pdf
Created by Independent Third Party: Yes
30343.9 09: 29ga TuffRib over plywood 29ga (min) TuffRib over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5
Other: 93.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf
@ 24" oc
Installation Instructions
FL30343_R2_II_29ga_TuffRib_Plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343_R2_AE_29ga_TuffRib_Plywood.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: