Loading...
HomeMy WebLinkAboutblower door- hodsonV i:'c~~,;g,;g~~it, Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 %.~ Phone: 772-462-2165 Fax: 772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method . Date: __ L_[ 1-_/ 1-_<> 1._t __ Permit#: ___ 'L_o_\_)_-_0_b_l _¥-____ _ Contractor: --+M....L...:5g_-i,[_, -1.R.~7:~C,,,....:!-a' "~f.:.i..+.,£,;.r~ .... .-1¢'..:..'.:.::1'\.__ ___ ----:---------- Job Address: ___ S_l :..,_l_rJ~e.~lL.....4--+.f.,.!!r'i;i;,1..f ---i;;.P.._r v~J~11---L~,,........;:~;.:.;l\~/=<2:o,-.i...,;;~=:"-4....,._, ...... fL......__.._3 ---''t-...._9...:....oa..f ..;..1 __ Construction: ( ,j) New Construction -Complete ( ) Existing-After Addition House Infiltration Test Results CFM (50) = .J 1 ( SLC Climate Zone 2 Test Date: ____ L__._{_L__._{_L_,)_1.._L.-_ Volume= 7 o 0° ACH (50) = CFM (SO) x 60 / Volume= 3 ' '1.... Passing results must be & ACH (SO) or less FBC, Energy Mechanical Ventilation required less than 3 ACH ( v1 Pass ( ) Fail The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding Z air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0 .2 inches w .. g. (50 Pascals}. Testing shall be conducted by either individuals as defined in Section 553.993(5} or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any t ime after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than l_air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (SO Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name : Pro-Duct Services Address : 1915 Rio Vista Drive, Ft. Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. /7()1.~ ---Signature: -----~-~"-L---__ -_____________ _ Printed Name: Martin Klein ----------------------- License/Ce rt i fi cation #: 5061633 --------------------