HomeMy WebLinkAboutApproved PlansProvide 26 gauge Galvalume corrosion resistant Ridge Anchor at all ridges. Fasten with 1 1/2" Neoprene Washer Screws 16"o.c. or approved roof nail 6"oc. CONTRACTOR TO VERIFY ROOF PITCH, HEEL HGHT. AND OVERHANG LENGTH. EXTERIOR FINISHES AND MATERIALS TO BE VERIFIED BY THE CONTRACTOR THAT THEY MATCH THE EXISTING RESIDENCE Ir , 12 a 5 See Connector FSChedule Two Course Perimeter-/ Beam with (1) #5 Rebar in each course, Filled with Grout luau:, • s . -� . ow,F.F.E_ "st (2) #5 Rebar Stucco Soffit with 2'-c" 8' x 16" vents 8'-0"o.c. See Stucco Soffit Note b m Light Textured Stucco Finish #5 Vert. Rebar with 10" Hook and 30" Lap. Tie to Vert. Rebar In Cells ` L-1 24 s.h. L_1 24 s h. DIEU Project Data 0 00 0 00 0 00 IE0o a— gfi I gfi I gfi 8" I 34'-8" 8" I I O I I 0 I I I I Limits of Slope Cing_ J b _ _ _ _ 13'-0" L-1 Ceiling I I Ceiling I I I I I 24 s.h. I o I I I I 30A I O I I L-1 r I I, �m 24 s.h. Garage 3080 I I L-� / 15'-0" Ceiling , ¢Q GDO i � GDO � ¢� GDO I i I T I I tv \ I I FPL Meter EP I I I I i L-3 L_4 1 L-3 / 100110 Overhead 100120 Overhead 100110 Overhead io Grade T-8" 10'-0" T-4" 19-0" Floor & EDeCtrlcaB IF-11an scale: 1/4" = r-O" 1°I 19-0" �I ELECTRIICAL. LEDQEND i SURFACE MOUNTED LIGHT FUCTURE F--1i --i SURFACE MOUNTED FLUORESCENT LIGHT FDcruFt: DUPLEX OUTLET -} SWITCH a I _ Ill,- -•, , :` •- .. / ,a ;;r • 1) �I I Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Safe Load Table Notes Installation Notes 1. All values based on minimum 4" nominal bearing. 1. Installation of U lintels must comply with architectural Exception: Safe loads for unfilled U lintels must and/or structural drawings. be reduced by 20% if bearing length is less than 6 1/2". 2. U lintels can be field cut to the required length. 2. N.R. = Not Rated 3. Cast in place concrete may be provided in composite U lintel In lieu of concrete masonry units. 3. Safe loads are superimposed allowable loads. 4. The exterior surface of U lintels installed in exterior 4. One #7 rebar may be substituted for two #5 concrete masonry walls shall have a coating of stucco rebar in 8 inch U lintels only. applied in accordance with ASTM C-926 or other approved coating. 5. All safe loads in units of pounds per tinier foot. 5. Concrete masonry units used in composite U lintel shall 6. All safe loads are based on simply supported span. be laid in a running bond. 7. Safe load ratings based on rational design analysis 6. Shore composite lintels as required. per ACI 318 and ACI 530. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and .g ,amr at grout. 8F16-1B/1� �fa rebar at bo nOMrel� — a arm m"Ity h-I r J Lintel Type Designation Cast Crete Lintel Schedule Composite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S All Rebar to be #5 Grade 60 min. MARK LENGTH OF ALLOWABLE LINTEL GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6" 11809 842 5861 711 8F60-1B/1T L-2 4'-8" 9311 215 4594 219 8RF58-1B/1T L-3 11'-4" 2423 1278 1738 1211 8F24-1B/2T L-4 11'-4" 4006 1 215 1 1749 1 219 1 BF36-1BAT Mim. Beam depths shown, beams may be increased without comment At Lintels over 24" deep provide (1) #4 vertical rebar at 24"o.c. along length of lintel (3) #4/0 AL in 2" PVC Wall Panel: 150 Amp 1150 Amp �I O 10 3W 40 Circuit Panel Ij t��l"jl M 120/240 Volt Electrical Load Calculations One 30 Amp R.V. Feed 7,200 watts Three Garage Door Openers 3,300 watts One 20 Amp Lighting Feed 1,920 watts (3) Recepticals 180OW each 5400 watts (2) 8'-0" 5/8" -/ Total 18,120 watts Grnd. Rods #4_ 18,120 W / 240 V = 75.5 Amps Use 150A Service ALL 120V SINGLE PHASE 16 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCL TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS C? C%J DO I= O W LL L Z C3 C CL W LL11;r W 00 > rz F- Z 0 UW�0 p •— J — CO UJ CC qe W (D~ cd U "> UJ CO E II W — 6 � —= _ ® co OHO U ®� �~ hN `V Q co co co UJ W Q Q tr) W W = in TERMITE TREATMENT REQU►RED Q W J ~ W I /1—DSD3 W ST. LUCK �7CQUNTY Pi J TTiG DIVISI N Q REVIEWED FOR L' CE ! REVIEWED B of DATE �� PLANS AIW EJLMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE hIADE. date revision (3) #4/0 AL in 2" PI PLANS AND ALL PROPOSED Wo ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER To COMPLY WITH ALL APPLICABLE CODES. to F.P.L. service ALL MANUFIt(,'7URE91.AUu`sB t71F40WTNG U FACTORS AND %*C COMPLIANCE Electrical Riser Diagram WrrHNALLD DOORS DMUST REMAIN ON ALL WINDOWS UNnL INSPECTIONS ARE APPROVED Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD drawn &I. checked sl. date 10/20/17 scale as noted job number 17080 sheet A-1 File Copy 0.00' A. 13'-0" - — scale: 1/4" e T-0" 0.0a - — - PRODUCT APPROVAL Approval Number Product Model Number Manufacturer Glass Type Attachment Method Building Rated Product Rated Design Pressures Design Pressures Head: 18" max from top corners. Jambs: 17.5" from top FL# 239A S.H. Windows 700 PGT Ind. Impact 15" max. from bottom comers and 6" max below meeting rail. Use 1/4" Tapoon with 1 1/4" min. embedment into +44.0 -47.9 +/- 80.0 concrete 6" from corners & 14"o.c. at Jambs & Head. Use 1/4" FL#: 5891.1 Swing Doors Fiberglass Therma Tru NA Tapccps with 1 1/4" embedment into concrete. +44.0 -47.9 +/- 67.0 Min. 2edge distance. FL#: 15371.1 Garage Door Model 824/811 DAB Door Co. N.A. Jamb Bracket Angle (3) total 5116" x 1 5/8" lag screws. (7) total +36.0 -44.0 +36.0 -44.0 Bracket 8'-0' height (1) 5/16" x 1 5/8" lag screws per bracket. Approval Number Product Model Number Manufacturer Attachment Method Building Rated Product Rated Design Pressures Design Pressures FL#: 3505.1 Roofing Hacienda Hanson (2) Corrosion resistant screws to penetrate plywood 3/4". #8 course tread mirt +34.4 42.1 scale: 1/4" ® T-0" scale: 1/4" a T-0" Right Bevation scale. 1/4" m T-0" +34.4 -42.1 y, • r Lu 5 `+ a (D uj Lu D :i c -f Y 1^1Jr 1 � L w W = CO U W Q J w W da drawn aL checked &I. date 10/20/17 scale as noted lob number 17080 sheet A-2 eA O File CopY Concrete shaii be a minimum of 4" thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. If concrete slab contains 6" x 6" 10/10 WWM provide 1" coverage Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. All 90% hooks are to be extended 10° minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3" in footings and 1 1/2" in bond beams. Hooks may be rotated horizonitaliy if required to achieve minimum coverages. Reber overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.sf. In the event the soil bearing capacity falls below 2000 p.sf. This foundation plan may be superceded by Foundation Design Engineer Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1/8" per foot for drainage Roof Framing Plan scale: 1/4" m T-0" No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. Design, Erection, & Removal of all formwork, shores, & reshores shall meet meet the ACI Standards 347 and 301 Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. SOIL STATEMENT: Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Fill shall be laid in layers of 6'. Each layer to be compacted to 95% compaction. If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be Inadecuate, he must immediately report it to the owner and the Architect or Engineer so as to order a soil boring test. In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4" from edges and 5" from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "Hilti 0-100" or Simpson Epoxy -Tie. 2 x 4 bottom corn bracinn 10'-0" Bottom Cord Lateral Bracing F-1 18" x 16" mono. footing with (2) #5 rebar cont. and curb 8" 4" to 6" 4„ ---- 16„ 18" CURB FOOTING AT GARAGE c 5'-9" 4'-2" 2'-5" 5'-8" d 5'-9" o �0 01 0 IEIEI Fill 00 0 oa o F-1 F-1 �? — — — — — ------------- :r✓ 8" 1 34'-8" I ga L0 i I I ASSUMED F.F.E. -4" I (Top of Curb 0.09) • I I � ®. I <°n I � 1 I I I I o ® I 00 1 F-� O 4" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, I TERMITE TREATED FILL I ev I c °; M I I I I Or) I I I 80 4" 2500# I o Cone. Pad FL1 z 1 ' I O � I I I I I I I Slope for Garage I Door (Typical) I I v ea T-j—F-1 Connector Schedule Truss Bearing Truss Connector Qnty' Connector Fasteners Point Uplift ID Uplift A08G 20 1211 HETA16 1 1810# (9) 10d x 1 1/2" 2 Ply 13 1113 HETA16 1 1810# (9) 10d x 1 1/2" (1) 5/8" die. ATR with 12" min. A04G 12 2541 MGT 1 3965# embedment, drill & epoxy and 2 Ply (22) 10d to Girder 21 991 HETA16 1 1810# (9) 10d x 1 1/2° B03G 8 291 MT818 1 1000# (14) 10d x 1 1/2" 1 Ply 5 290 MT818 1 1000# (14) 10d x 1 1/2" B01G 1 1284 MTS18 2 2000# (14) 10d x 1 1/2" per strap 2 Ply 7 1284 MTS18 2 2000# (14) 10d x 1 1/2" per strap All other trusses ALL <1000 MT818 1 1000# (14) 10d x 1 1/2' to Frame All other trusses ALL <1810 HETA20 1 1810# (9) 10d x 1 1/2" to CBS Valley g Framng (4) 10d Trusses 8250# VTCR 1 370# Tanis (3) 10d x 1 1/2" Connector Schedule Dev-laic: r from the Truss Placement Plan ♦i Engineering from ast •. Job Number J34712 Dated 10/17/17 Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to appprove temporary bracing to prevent toppling of trusses, see T11B-9. Other specs, if different from above, have priority. Drill and Epoxy Set all AT.R. Use either "Hilti" C-100 or Simpson Epoxy pwj Provide Two Studs under Joint 16 of A10G [am 1'-4" 1 Foundation & Footing Plan scale: 1/4" a T-0" See Civil Drawings for Concrete Driveway Layout r 1'-4" 1 M tom• �i • i_ 11 �t 0 U W E— co r 2 Rd') ® � z N U®� ® OD U)8; v as cr coco 0 _ CO U LL1 < J w W drawn at checked Si. date 10/20/17 acme as noted job number 17080 sheet A-3 File -Copy 4' Wind Zones - Walls Gross Wind Pressures End Wind Trib: Zones- PSF 1 2 3 4 5 Zone Speed Area +40.5 +40.5 d10 s.f. -37.0 -64.5 -95.4 -43.9 -54.0 20 s.f. -36.0 -59.3 -89.2 -42.1 -421 -50.5 -50.5 4 ft. 150 mph +36.2 +36.2 - 50 sf. -34.6 -52.5 -81.0 39.7 -45.7 100 s.f. -33.6 -47.3 -74.8 +34.4 +34.4 37.8 -42.1 500 s.f. +30.2 +30.2 -33.6 -33.6 Gross pressures are for windows, doors, framing, roofing, and other building components and cladding. Roof Zones: 1 thru 3 Wall Zones: 4 and 5 STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30" in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1" concrete cover, or as follows. • ■ � tZ�I=��T Beams: 11/2" 11/2" 11/2' Slab on Grade: 11/2" 1" _ Structural Poured: 3/4" 3/4" Poured Walls: 3/4" Slabs exposed to the weather 3/4" 1" _ Reinforcing steel shall be detailed and fabricated in accordance with the "Manual of Standard Practice of Detailing Reinforcing Concrete Structures" and the current "ACI Building Code 318" All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved separating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. No slump over 5" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACO. and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fc') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb®1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1/360 max. deflection. All bolted connections shall be 1/2" Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project, unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors ;method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8' high ribbed galy. wire lath fastened to framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" dia. head 6"o.c. max edges to be tied and nailed at 9"oc. Install one layer of 15# felt to framing prior to installing ribbed lath GENERAL. ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and end laps, fasten with corrosion resistant annular ring shank nails at 6"o.c. in laps and in staggered rows spaced 12"oc. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. 5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"oc. throughout, except max 40oc. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida registered professional an certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturer's certified layout shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and date. All engineered headers and truss hangers to be provided by the truss manufacturer. Splitting or cracking of structural components due to installation of hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and standard practice. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH TO BLOCK WITH 1/4" DIA TAPCONS INTO C.B.S. SET AT 6" FROM CORNERS AND AT 12"oc. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "r NAILS" 4" FROM ENDS AND 12"o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2: 8d at 4"oc. edges & field Zone 3: 8d at 4"oc. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter..113 Min. Length: 2" Min. Head Diameter: 280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Nailing Schedule ROOF DIAGRAM Use sheathing with #8 gun nails at 6"oc. at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. 8' x 16" C.M.U. WITH CELLS FILLED WITH GROUT & (1) #5 VERT. q DOWEL �.. P.T. 2 x 6 AT (3) SIDES OF OPENING, FASTEN TO BLOCK AS NOTED. I DOOR SIDES 5/8" x 6" REDHEADS WITH MIN. 1 2" x 1/8" WASHER 12" FROM ENDS AND 24"oc. MAX �I !� DOOR HEAD 1/4" x 2 3/4" TAPCONS STAGGERED 24'o.c. Gee ®®®r Buck ®etas corner bars at beam (outside only) (2) corner bars at footing (min) vert. dowel lapped with wall reinforcing, all laps 25' (min.) in grout filled cell sssssss= --- all corner bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls 3/8" continuous bead of caulk (back bedding) behind - buck to prevent liquid passage 0 y Min. 1 1/4" embedment at Windows and min. o � ® a aY.4 1 1/2" embedment at ®� 00 d °sl. gl. doors - c 0o �o0 COO 4. 16 '0� i �1/2" drywall ®U ttoo 00 ° stucco finish perimeter cau$ .- • 1/4" max. struct. shim I- 1 Window & Door Flashii Includes Buck Attachment Method Alum. window frame , 3/8" continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1/4" struct. shim - set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish-, a corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval Gunable sealants shall comply with ASTM C 920 Class 25 grade or ° ° a greater for proper joint expansion and contraction precast conc. sill Typical Precast Conc. Sill Detail 90 DEGREE HOOKS OVERLAP 25" MIN. - z �L. 1 • .r c1; JL W Ix CO drawn s.t checked a]. date 10/20/17 scale as noted job number 17080 sheet A-4 File Copy ­".._.