HomeMy WebLinkAboutEnergy Calculation Form & Manual J's I
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING; CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential;Performance Method
Project Name: 5203 Sunset Blvd Builder Name: Mike DiFrancesco
Street: 5203_Sunset Blvd Permit Office: St Lucie NOV 2 0 201?
City,State,Zip: Fort Pierce,FL,34982 Permit Number: .
Owner: Jarvis Jurisdiction: 611000 PERMl1-Tl;gG
Design Location: FL,STLUCIE_CO_INTL County:: St.Lucie(Florida Clilmate Zone 2§t• Lucie County, FL
1. New construction or existing New(From Plans) 9. Wall Types(1392.0 sqft.) ; Insulation Area
a.Concrete Block-Polystyrene Bead AggiR=0.0 1137.00 ft2
2. Single family or multiple family Single-family �
b.Frame-Wood Adjacent R=13.0 255.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
10.Ceiling Types (1074.0 sqft.) Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) i R=20.0 1074.00 ft2
6. Conditioned floor area above grade(ft2) 1074 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(158.3 sqft.) Description Area a.Sup:Attic,RetJ Main,AH:Mai ri 6 214.8
a. U-Factor. Dbl,U=0.29 92.94 ft2
SHGC: SHGC=0.21
. b. U-Factor: Dbl,U=0.35 33.33 ft2 12.Cooling systems � kBtu/hr Efficiency
SHGC: SHGC=0.24. a.Central Unit 17.6 SEER:16.00
i
_ c. U-Factor: Dbl,U=0.28 32.00 ft2
` SHGC: SHGC=0.18 13.Heating systems kBtAr Efficiency
d. U-Factor: N/A ft2 a.Electric Strip Heat 16.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.625 ft.
Area Weighted Average SHGC: 0.210 14.Hot water systems
8. Floor Types '(1074.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.980
a.Slab-On-Grade Edge Insulation R=0.0 1074.00 ft2 b. Conservation,features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.147 Total Proposed Modified Loads: 41.90 PASS
Total Baseline Loads: 42.81
i
I hereby certify that the plans and specifications covered by Review of the plans and ti_fHE Sr9T
this calculation are in compliance with the Florida Ener y specifications covered by this
Code. calculation indicates compliances
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: this building will be inspected foci
compliance with Section 553.908
I hereby certify.that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. CAD WE' D
OWNER/AGENT: BUILDING OFFICIAL:
DATE: o 73 DATE:
- Compliance requires certification by the air handler unit manufacturer that the ai i handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this
project requires an envelope leakage test report with envelope leakage no greater than 5.0 ACH50(R402.4.1.2).
File C®py
11/13/2017 9:50 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4
i a
FORM R405-2014
PROJECT
I
Title: 5203 Sunset Blvd Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1074 Lot#
Owner: Jarvis Total Stories: 1 BlockiSubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Mike DiFrancesco Rotate Angle: 0 Street: 5203 Sunset Blvd
Permit Office: St Lucie Cross Ventilation: County; St.Lucie
Jurisdiction: 611000 Whole House Fan: City,State,Zip: Fort Pierce,
Family Type: Single-family FL, 34982
New/Existing: New(From Plans)
Comment: j
I
CLIMATE
/ IECC Design Temp In Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summers Degree Days Moisture Range
FL,ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 i70 75 I 299 58 Medium
BLOCKS
Number Name Area Volume
1 Block1 1074 9666
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Ind ID Finished Cooled Heated
1 Main 1074 9666 Yes 3 2 1 Yes Yes Yes
FLOORS
i
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
i
1 Slab-On-Grade Edge Insulatio Main 149.7 ft 0 1074 W — 0 0 1
ROOF
Roof Gable Roof Solar SAi Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Metal 1163 ftz 0 ftz Light 0.6 No 0.9 No 20 22.6
'I
ATTIC
V # Type Ventilation Vent Ratio 1 in Are RBS f IRCC
YP ( )
I
i
1 Full attic Unvented 0 1074 ft2 N N
I
CEILING j
# Ceiling Type Space R-Value Ins Type Area jl Framing Frac Truss Type
1 Under Attic(Unvented) Main 0 Blown 1074 ftz 0 Wood
I
I
I
i
I
I
i
11/13/2017 9:50 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 4
i
I
' I
FORM R405-2014
WALLS
I
Adjacent Space Cavity Width Height (Sheathing Framing Solar Below
1 N Exterior Concrete Block-Polystyren Main 0 23 9 207.0 ft2 I 0 0 0.75 0
_ 2 N Garage Frame-Wood Main 13 24 8 9 222.0 ft2 1 0 0 0.75 0
_ 3 E Garage Frame-Wood Main 13 3 8 9 33.0 ft' 0 0 0.75 0
4 E Exterior Concrete Block-Polystyren Main 0 26 9 234.0 ft2 0 0 0.75 0
5 S Exterior Concrete Block-Polystyren Main 0 15 9 135.0 ft2 0 0 0.75 0
6 S Exterior Concrete Block-Polystyren Main 0 33 9 297.0 ft2 0 0 0.75 0
_ 7 W Exterior Concrete Block-Polystyren Main 0 29 4 9 264.0 ft2 0 0 0.75 0
i
i
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated Main None .4 3 1 6 8 20 ftz
2 E Insulated Main None .4 3 6 8 20 ft2
I
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall I Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.28 0.18 16.0�ft2 2 ft 0 in i1 ft 0 in None None
2 E 4 Vinyl Low-E Double Yes 0.29 0.21 7.1 ft2 9 ft 4 in 11 ft 0 in None None
3 E 4 Vinyl Low-E Double Yes 0.29 0.21 16.2 ft2 9 ft 4 in 1 ft 0 in None None
4 S 5 Vinyl Low-E Double Yes 0.35 0.24 33.3!ft2 9 ft 4 in 1 ft 0 in None None
5 S 6 Vinyl Low-E Double Yes 0.29 0.21 64.8 ft2 2 ft 0 in 1 ft 0 in None None
6 S 6 Vinyl Low-E Double Yes 0.29 0.21 4.9 ft2 2 ft 0 in 11 ft 0 in None None
7 W 7 Vinyl Low-E Double Yes 0.28 0.18 16.11 ft2 2 ft 0 in 1 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 317.44 ft2 317.44 ft2 46.8 ft 1 9 ft 1
I
INFILTRATION
I �
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000286 805.5 44.22 83.16 .2144 ! 5
HEATING SYSTEM
# System Type Subtype Efficiency I Capacity Block Ducts
1 Electric Strip Heat None C0P:1 16 kBtu/hr 1 sys#1
i
I
'I
1 'I
I
11/13/2017 9:50 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software ! Page 3 of 4
'I
I
FORM R405-2014
COOLING SYSTEM
i
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
i
1 Central Unit None SEER:16 17.6 kBtu/hr 528;cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.98 40 gal 50 gal! 120 deg None
I
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25' CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 214.8 ft Main 53.7 ft2 Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Coolin (( ��Jan Feb Mar W r I IMay rl Jun JXJ Jul X Au rl Se Oct Nov Dec
`Heating [X]Jan Feb Mar r Ma Jun Jul L AuSeP Oct Nov Dec
Ventin [[ ]]Jan Feb X Mar r May Jun Jul [ Aug Se Oct HX Nov H Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
i
Cooling(VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 . 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 .66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
j
a
I
• I
I
I
i
i
i
I
I
11/13/2017 9:50 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4
� I
I
I
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD;
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5203 Sunset Blvd, Fort Pierce, FL, 34982
i
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block'-Polystyrene Bead AggiR=0.0 1137.00 ftz
b.Frame-Wood;Adjacent R=13.0 255.00 ft
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 2 d.N/A R= ftZ
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 1074.00 ftz
6. Conditioned floor area(ftz) 1074 b.N/A R= ftz
7. Windows'" Description Area c.N/A R= ftz
a. U-Factor: Dbl,U=0.29 92.94 ftz 11.Ducts R ftz
a.Sup:Attic,Ret:Main,AH:Main 6 214.8
SHGC: SHGC=0.21
b. U-Factor: Dbl,U=0.35 33.33 ftz
SHGC: SHGC=0.24 12.Cooling systems) ! kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.28 32.00 ftz a.Central Unit 17.6 SEER:16.00
SHGC: SHGC=0.18
d. U-Factor: N/A ftz 13 Heating systems kBtu/hr Efficiency
.
SHGC: a.Electric Strip Heat 16.0 COP:1.00
Area Weighted Average Overhang Depth: 4.625 ft.
Area Weighted Average SHGC: 0.210
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1074.00 ftz EF:0.98
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
I
15.Credits CF,Pstat
'i
I certify that this home has complied with the Florida Energy Efficiency Code for Building �>ttr sT
Construction through the above energy saving features which will be installed (or exceeded) tioF, : ATFo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code complianlleatures
Builder Signature: Date: 2,017
Address of New Home: 5"ad3 Svcs ca 3Lv� f-'r �re��. City/FL Zip: 3 y yQ� •coov��
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1 111 3/201 7 9:51 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: 5203 Sunset Blvd Builder Name: Mike DiFrancesco
Street: 5203 Sunset Blvd Permit Office: St Lucie
City,State,Zip: Fort Pierce,FL,34982 Permit Number: !
Design Location: FL,ST LUCIE_CO_INTL Jurisdiction: 611000
Cond.Floor Area:: 1074 sq.ft. Cond.Volume: 9666 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: 6FM(50):
C: n: R:
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: I
1 Pa cfm ACH:
I
2 Pa cfm SLA:
i
3 Pa cfm
ACH(50)
4 Pa cfm *For prescriptive projects, tested leakage must be
5 Pa cfm <-
-7 ACH(50).50 . For erformance projects, tested
( P
6 Pa cfm leakage must be <=the ACH(50) shown on Form
R405-2014 for this prloject.
R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.d.(50 Pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth!in Section 489.105(3)(f) (g),or(i)or an approved
third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing shall be conducted by either HE S
I hereby certify that the above envelope leakage �� TAP
individuals as defined in Section
performance results demonstrate compliance 553.993(5)or(7), Florida Statutes or `;�;
with Florida Energy Code requirements in individuals licensed as set forth in a ,r,� x:'•. °;;,,,�O
'' :=-';
accordance with Section R402.4.1.2.
Section 489.105(3)(f), (g),!or(i)or an c� —:_;-
approved third party. A written report
E:;l., .
SIGNATURE: of the results of the test shall be
signed by the third party conducting
PRINTED NAME: the test and provided to the code COD wrc
I
BUILDING OFFICIAL: j
DATE: DATE:
i
I
11/13/2017 9:51 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1