Loading...
HomeMy WebLinkAboutEVALUATION REPORTNEMO f ete. Certificate of Authorization #32455 353 Christian'Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER `EVALUATE TEST CONSULT REPORTEVALUATION Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11:08-R11 One Owens Corning Parkway FL11601-1111 Toledo, OH 43659 Date of Issuances 31/03/1008 (740) 321-6345 Revision 12:12/16/2020 SCOPE: This Evaluation Report is :issued under Rule 6100-3 and the applicable rules and regulations governing the use of construction materials in the State of Rorida. subrnitted'hzs been'retiiiewed by Robert Nierninen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 76 Edition (2020) Florida Building Code sections noted herein: DEselPnohl TitanumTM Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) _Changes, the referenced Quality Assurance or production facf(ftj focatfon(sj changes, or Code .provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the'Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete'review of its .Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. 'Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety: INSPECTION: Upon request, a copy of this entire Evaluation Report shall be.provided to the user by the manufacturer or As distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ,•":€"::�1�•.', Robert J.M.:Nieminen, P.E. Fps=.^ �'•,� s''=T The facsimile seal appearing was authorized by Robert .Florida Registration No. 59166, Florido DCA ANE1983 "zri �;„;, 4� �t Nieminen, P.E. an I2/Y6jZOZQ. This does not serve as an 'document electronically signed CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in .any company'manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3: Robert Nierninen, P.E. does not have'nor will acquire, a financial interest in any company manufacturing or distributing products for which :the evaluation reports are being issued. 4. Robert Nieminen, RE: does not have, nor will acquire, a firianbal interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, "LLC nor Robert NiL-Minen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for'permitting'or design guidance unless retained specifically for that purpose. 02018 MEMO ETC, LLC ONEMOjetc. ROOFING COMPONENT EVALUATION: r• Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titaniumt" Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 11 Edition (2020) Florida Building Code through testing in accordance with applicable sections the following Standards. 'Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Z. .AR. Section Prove Standard Year 1504.3.1 Wind resistance UL 1897 2015 1507.1.1, 1501.2.4, 1507.2.9.2 / 11905.1.1, Material standard ASTM D1970 2015 R905.2.8.2 1507.1.1.1(2&3, Exception),1507.1.1.1(5) / Tear strength ASTM D4533 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception),1507.1.1.1(5) / Tensile strength ASTM D5035 2011 R905AAA(2&3, Exception),'R90SAAA(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4969 2016 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition •2018 TA5110 Accelerated Weathering ASTM D4799 2011 Entity Examination Reference Date ERD (TST6049) Various, system tests 135520.06:11 06/15/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ERD (TST6049) FRSA/TRI, tile slippage 4j-OC-19-55UDL-01.A 05/14/2019 ITS (TST1509) FRSA/TRI, partial 3126617COQ 005 10/31/2007 ITS (TST1509) ASTM 04869, LWT 101823107COQ-007A 12/09/2014 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) FRSA/TRI, partial OCF-343-02-01 11/09/2017 PRI(TST5878) ASTM D4798;D1970 OCF-341-02-01 11/27/2011 PRI (TST5878) TAS 117(B); Pull -through OCF-422-02-02 04/03/2018 PRI(TST5878) FRSA/TRl,partial OCF-425-01-01 08/13/2018 PRI(TST5878) UL1897 1378TO02 07/10/2019 Oki (TST5878) ASTM D1623, TAs 103 btF-507-02-01 08/13/2019 PRI(TST5878) UL1897 137ST0117 10/20/2020 PRI (TST5878) ASTM 04533, D4798, D5035 1378TO110 10/15/2020 PRI(TST5878) ASTM D4533,D4798,D5035 1378T0111 10/15/2020 PRI(TST5878) ASTM D4533,D4798,D5035 1378T0112 10/15/2620 ITS (QUA1673) Quality Control Service Confirmation 12/09/2020 ITS (QUA1673) Quality Control Florida BCIS Current 4.. PRODUCT DESCRIPTION: e_ 4.1-- Product materizi Stamiarti Plmms) best r+ption :Tifanutn�`P5ll30 ASTM D1970 and Dubai, UAE unreinforced polymer modified bitumen material FRSA/TRI 09-18 Brentwood, NH adhered to the underside of a polymer -coated, synthetic woven sheet. The underside Is backed with a release film. Unit welght 24 Ibs/square MEMO ETC, LLC Eva)uation Report J11980.11.08-R12 Certificate ofAuthorizotion k32455 7O1 EDITION (2020): FBC NON-HVHZ EVALUATION FL11602-R11 Titanium Roof Underlayments Revision 12:1211512020 Page 2 of 8 4.2 4.3 4.4 ONEmoletc. Product Material'Standard Plant(s) :Description Titanium'" UDL-25 1507.1.1.1(2&3, Qingdao, China synthetic sheet -type underlayment comprised of Exception), 1507.1.1.1(5) / a woven core coated on one side with a polymer R905.1.1.1(2&3, coating. Unit weight 2.5 lbs./square Exception); 1`1905.1:1A(5) Titanium- UDL-30 1507.1,1.1(2&3, Qingdao, China synthetic'sheet-type underlayment comprised of Exception), 1507.1.1.1(5) / a woven core coated on both sides with a R905.1.1.1(2&3; polymer coating. Unit weight 4.0 lbs./square Exception), R905.1.1.1(5) Titanium— UDL-SO 1507.1.1.1(2&3, Qingdao, China synthetic sheet -type underlayment comprised of Exception), 1507.1.1.1(5) / a woven core coated'on both sides with a R905.1.1.1(2&3, polymer coating. Unit weight 4.7 lbs./square Exception), R905.1.1.1(5) 5.1 This is a building code evaluation. Neither NEMO ETC,.LLC nor Robert, N ieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. 5.2 This Evaluation, Reportis not for use in FBC High Velocity. Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof. components. Roof decks and structural members shall be in accordance, with FBC requirements to the satisfaction of the Authority Having Jurisdiction: 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to :FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 TitaniumTTM Roof Underlayments may be used with `any prepared roof cover where the product'is specifically referenced within FBC approval documents. If not listed, a request may 'be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting:data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS° FSCSection: 1507.2 i507.3 1507:4 &'1507.5 : 1507.7 1507.8 & 1507.9 Asphalt Clay and Concrete Tile Metal Panels Slate or'Slate- . Wood Shingles and Mechanical Adhesive- Underlayment Shingles and Shingles Type Shingles Shakes Attach Set tanium PSU-30 Yes Yes Yes Yes Yes Yes (Jolnt strips, 2507.1.1.3/ (See 5.6.1) R505.1.1.3) Titanium UDL-25 Yes No No Yes Yes No Yes Yes Titanium'UDL-30 Yes (Base Sheet in (Base Sheet in Yes Yes No 2-ply system) 2-bly system) Titanium UDL-50 Yes No No I Yes Yes No NEMO ETC, LLC Evaluation Report 111980.11,08-R12 Certificate ofAuttiorization #32455 7- EDITION (2020) FBC NON.HVHZ EVALUATION FL11602-RII Titanium Roof Underlayments Revision 12:12/16/2020 Page 3 of 8 *.NEM0'J etc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE IA'-. ALLOWABLE TILEADHESIVE / UNDERLAYMENT COMBINATIONS) Underlayment Adhesive Florida ProducEApproval Titanium PSU-30 Dupont "Tile Bond'"' Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants "Polyset® AH-160" FL6332 ICP Adhesives and Sealants "Polyset° RTA-1" FL6276 5.7 Allowable Substrates: TABLE ,2: SUBSTRATE.OPTIONSFOR ADHERED'UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer Material(s) Titanium PSU-30 self -adhering Deck / sheathing (Optional) ASTM D41 Plywood Base sheet None ASTM D226, Type II felt ASTM D41• Titanium UDL-30 None Titanium UDL-30 (inverted) 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached'NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments'or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof Systems, attachment shall be in accordance with the manufacturer's installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to Underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in'accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority. Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies Titanium PSU-30; self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 111980.11.08-R32 Certificate of Authorization k324SS 7- EDITION (2020) FBC NON-HVKZ EVALUATION FL11602-R11 Titanium Roof Underlayrnents Revision 12: 12/16/1020 Page 4 of 8 ONEMOIetc. #2 Maximum Design Pressure = -142.5 psf: Deck: Mina 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction: Primer: None Underlayment: one ply Titanium :PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements: 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for'the selected assembly shall meet or exceed that required under FRSA/TRI Florida High' Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential -Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #3 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with rein. 32 ga.,1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed Max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-Inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 94 Maximum Design Pressure = -30 psf*.: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12,ga. annular ring shank nails having not'less than20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through -the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps: Spacing: 6-inch o.c, at 4-inch wide side laps and 12-inch o.c. at three:(3), equally spaced center rows. Primer: ASTM 041 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max: 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. MEMO ETC, !LC Evaluation Report 111986.11.08-R12 O.N EK401 etc. #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-Inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. , Underlayment:. one or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #6 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch :plywood to meet project requirements to satisfaction of Authority Having jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ringshank nails having not less than 20 rings per inch, heads not less than 3%8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41.primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.9 Exposure Limitations: TABLk 3:r•ExposuRE,LimiTATIONS ; Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Titanium PSU-30 Mechanically attached 180 Adhesive -set the 30 Titanium UDL-25, Titanium UDL-30, titanium.UDL-50 Mechanically attached 180 MEMO ETC, LLC Evaluation Report 111980.11.08-R12 Certificate ofAuthoriiatlon N31455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R11 Titanium Roof Underlayments Revision 12:12/16/2020 Page 6 of 8 ONEMO[etc. 5.10 Tile Slippage Limitations: When loading roof .tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall :be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4 TILESLIPPAGE,LIMITATIONS FOR';DIRECTrDECK,TILE.INSTALLATIONS: Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 Flat Max,10-tile stack 5:12 Flat Max:5-tile stack 6:12 Lugged Max. 10 file stack 4:12 Lugged Max. 5-tile stack 5:12 Lugged Max. 10-tile stack (5 over 51 5:12 6. INSTALLATION: 6.1 Titanium Roof Underlayments shall be installed in accordance withOwens Corning Roofing and Asphalt, LLC published installation'requirements subject to the Limitations set forth in Section 5'herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the -substrate .thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Titanium'"' UDL625, Titanitim UDL-30 oe Titanium..UDL-50 . ;. 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1501.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1501.1.1.1(5) or FBC Residential 11905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905:1.1.1(5) for the type of :prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's Installation instructions. 6.3.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails -shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.4 Titanium"" PSU-30:. 6.4.1 Non -Tile Applications: Shall be'inetall'ed in compliance with requirements for an approved self -adhering underlayment (ASTM 01970) in FBC'1507.1.1.1 or 1501.1.1.3 or FBC Residential 11905:1.1.1 or 11905.1.1.3'forthe type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type li:felt, the felt shall be fastened in accordance with:FBC 1507.1.1 or 4905J1.1. NENIO ETC, LLC Evaluation Report 111980.11.08-R12 Certijlcate o/Authorizatioa N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL31602-Ril Tltanium''Roof Underlayments Revlslon-12:12/16/2020 :Page 7 of 8 O,NEMOjetc. 6.4.2 Tile Applications: Shall be installed in compliance with requirements for a Self -Adhered Membrane In the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section S.8.3 for attachment limitations. Refer to Table 4 for tile staging limitations, 6.5 Titanium•2-PlySystein: 6.5.1 The Titanium 2-Ply System consists of :a base layer of Titanium UDL-30 (top=surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered, 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. 6.5.3 Tile Applications: Refer to Section 5.8.3 for attachment limitations. Refer to Table 4 for tile staging limitations. As required by the Building, Official or Authority Having Jurisdiction to properly evaluate the installation of this .product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY Intertek Testing Services NA Inc. — QUA1673; (312) 906-7779; mauramorlanderWritertelc.com END OF EVALUATION REPORT NEMO ETC, LLC Evaluation Report 111980.11.08-R12 Certificate of Authorization A32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION fL11602-R11 Tltaniurn Roof Underlayments Revision 12:12/16/2020 Page 8 of 8