HomeMy WebLinkAboutProduct Approval 1-20-211/19/2021 Florida Building Code Online
T--'T"--'--°---'--•T'4--'�^'—" r , r
v y a J tee' x was
5
3
W.
BCIS Home ' Log In 'User Registration Hot Topics I Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links I Search
��011dil
JProduct Approval
I S USER: Public User
r
Product Ago.tgydMen . > Product or Agolication search > Qpplicatlon List > Application Detail
FL-*
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL1w702L--R8
Revision
2020
Approved
File, Cory
9-# ozo I -6qqs R
REVIEWED FORF�Ei�Fo
CODE COMPLIANC 4N �
STo LUCIE COU1NT°�t uc, ® 2021
e.
W BOCC *32- rMjtt
Ins my
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Richard McKuhen
fivalidation@yahoo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.het
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
' Evaluation Report -'Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc,
Quality Assurance Contract Expiration Date 04/22/2024
Validated By -James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL17022 R8 COI 26ga VMAX pywood.odf
Standard
Year
TAS 100
1995
TAS 125
2003
UL 580
2006
https:llfloridabuilding,orglprlpr app_dtl.aspx?param=WiSEVXQWtD4v2aBQpHpQQe6rMZMkUEoR%2bd%2buNxXG%2bnlRhGTtoBWMlaQ%3d%3d 113
1 /19/2621
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending.FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
10/05/2020
10/12/2020
10/25/2020
12/15/2020
12/16/2020
FL #
Model, Number or Name
Description
17022,1 W
01: 26ga VMax on P,ly.4 od
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood 6r'3/4" (min) thick wood plank.
Limits of Use
Approved for use in HVHZ: No
Approved'for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL17022 R8 II 26ga VMAX piywood.pdf
Verified By: David Eng; PE 81377
Created by Independent Third Party: Yes
Design Pressure: +N/A/-228
Other: Refer to evaluation report.
Evaluation Reports
FL17022 R8 AE 260a VMAX .plywood df
Created by Independent Third Party: Yes
17022.2
02: 032 Aluminum VMax on Plywood
.Nominally 0.032".aluminum (or thicker) VMax 5V'panel with
21" Coverage on 15/32" (min) plywood or 3/4" (min) thick
wood plank,
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
'Other: Refer to evaluation report.
Installation Instructions
FL17022 R8 II '032 VMAX 21in p_ywood:pdf
Verified By: David Eng, PE.81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R8 AE 032 VMAX 21in pjywood.pdf
Created by Independent Third Party: Yes
17022.3
03: 26ga VMax on Plywood
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-114.25
Other: Refer to evaluation report.
Installation Instructions
FL17022 R6 -jr 26ga UMAX PiYAon fiats.odf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R8 AE '26ga VMAX o1Ywood flats.pdf
Created by Independent Third Party: Yes
17022.4
04: 26ga' CorMax on Plywood
26ga (min) CorMax corrugated panel with 29.5" coverage on
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use.outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL17022 R8 II 26ga CorMax Plywood HVHZ.pdf
Verified .By: David Eng, PE 81377
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Other: Refer to evaluation report.
Evaluation Reports
FL17022 R8 AE 26ga CorMax Plywood .HVHZ.odf
Created by Independent Third Party: Yes
17022.5
05: 26ga CorMax on Battens
26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens,
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL17022 98 II -26ga CorMax Battens.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
:Design Pressure: +N/A/-161
Other: Refer to evaluation report.
Evaluation Reports
FL17022 RB AE 26ga CorMax 'Battens.pdf
Created by Independent Third Party: Yes
tack Nnxt
Contact Us :: 2601 Alair'Stone Road, Tallahassee Fl. 32399 Phone: 850.487-1824
The State of Florlda is an AA/EEO employer. Copyright 2007-2013 State of Florida.:-. Privacy ement :: Accessibility Statement :: Refund Statement
Under Florida law, "email addresses are public records. Y you do not want your e-mail address released In response to a public -records request, do not send 'electronic
mail to this entity. Instead, contact the ofnce by phone or by traditional mail. If you have any questions, please contact 850.467.1395. *pursuant to Section 455.275(1),
https://floridabuilding.org/pr/pr app_dtLaspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bd%2buNxXG%g2bnlRhGTtoBWM16Q%g30%3d 2/3
1/19/2021
Florida Building Code Online
Florida Statutes, effective October 1,'2012, Ilcensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for official'communlcation with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
;provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hg er
Product Approval Accepts:
M �' l ® ECAGC m
Credit Card
Safe
https://floridabuilding.org/prlpr_.app_dtl.aspxlparam=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRa/o2bda/o2buNxXG%2bnlRhGTt6BWM18Qa/o3da/o3d' 3/3
XMMETAL
FABRICATORS
SKILLED CRAFTERS OF METAL ROOFING SYSTt= M,S
26go (min) VMAX over 15/32" (min) plywood
Extreme Metal Fabricators
2120 SW Roma Dr I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/81.
Product Mater`ia'l
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min 'S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL RE 81377 1 FL CA 33344
www.Tim'berLakeCove.com
.101111110/1,
I � ■ ■!'l /\ 17. yY .� t! c 'r ,,� -.Y 4 a Y f� i' a 1., 'U F. ,.
:i r A -' ua � � � � �. :r Y � bk a f -�5 � _ 1/.• s Sn s 1 ' n �' t
�..��. ,.. }.._.................. ,... t�i�+...�...;_z....,r—.s,.'�:...a....y.1. fs::..:.,u. ._.r��:,�,...�.'1` " w.:..._..e �:. ..�:,._,.!._,,... .3^._......:...;3�::.r.r>. .:�.-:
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be installed over a single [dyer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the .conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A• #9 x 1 5"fastener in 12"-12" pattern at 16f'o.c.: 86 PSF
Method B• #10 x 1 5" fastener in 12"-12" pattern at 16" o.c-: 93-5 PSF
Method C•:#10 x 1 5" fastener in 12"-12" pattern at. e" o.c.: 101 PSF
Method D• #10 x 1 5" fastener. in 12"-12" pattern at 6" o.c_: 228'PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D'05893:02-450-18. As referenced in
FL 17022.01-147
Compliance Statement:
This product .as described has demonstrated compliance with Florida. Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Ru"le 61G20-3, method 10.
This product :as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems -
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7; or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of 'these tables assumes that the structure is:
• .Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideratlion
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake cove, LLC do not have, nor will acquire a fln'oncial interest In any company
manufacturing or distributing products under this evaluation. The same entitles do not have, nor will
acquire; a financial interest:in any other entity involved in the approval process of the -product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood pla}ik).sholl be completed by
others. Fire classification and'shea'r diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to 'compliance with structural wind ;load requirements of FBc 1504.3.2;. as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and .makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code -and authority having
jurisdiction; this report'shall not be construed to supersede local codes in force.
tl r Lv t ram, K ° � f, - .i x VI♦ � J �'"� \� 4.;��� l� 7_E �'ys—k �.—e��:
,A4Y
'Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the .design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 -and FBC 2020 adopt a 7-zone concept.
For the load tables below, the Worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
a-
2.
2
3
2 I
1
2
2
2 1 2
2
2
2
3
3
a
a
1
2
1
2
3
3
7 1.� WiP RMF
rAR1 E RO6F "'^
'a
Combining these zones creates a clear, simple AI0%OFLEAST H02ONTALOWENS= OR 0 AA. WHICHEVER IS SWUM BUT NOT
P LESS THAN EITHER A%OF LEAST HORIZONTAL OR@NSION OR 3FT(0 SM).
scheme, at the expe'n'se of some design efficiency. ORASDETERMINED By DESIGN OR OTHER APPLICABLE COOS
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A: METHOD B: METHOD C. METHOD D:
#9 AT 16" O.C. #10. AT 16" O.C. #10 AT 8" O.C. #10 AT U' O.C.
r----12" (NOM) 12" (NOM)----I NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
- r
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gablelhip roof with max slope of 12:12
Have a mean Roof He of 30 feet or less
FL17022.01: 26ga 5V Crimp on 15/32" plywood
Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A C D Iti D
Zone 3: A A A A A A
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof less than 70, hip roof with
max slope of 12,12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30feet or less
Wind 105 110 120 130 '140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A B C
Zone 3: A A, A A A A_ A. B ;D . r D;:. ,
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max -slope of 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26ga,_5V Crimp on 15/32 plywood.
Wind
105 110
120
130 140 150 160 170 180 190,20
Zone 1:
A A
A
A A A A j�C {L D r
Zone 2:
A A
A
A G D
Zone 3:
A A
A
r G D._: .D _,Q
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure'area
Have either a flat roof less than'7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
Wind
105 110'
120
130 140 150 160.170 180 190 200
Zone 1:
A A
A
A A A A
Zone 2:
A A
A
A A BDI
Zone 3:
A. A
A
.z }