Loading...
HomeMy WebLinkAboutProduct Approval RoofingFlorida Building Code Online Page 1 of 2 Product Aooroval Menu > Product or Aoolication Search > Aoolication List > AppliMt!Cn Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License QualityAssurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL28113-R3 Revision 2020 Approved Integrity Metals LLC 2604 B Piper Drive Vero Beach, FL 32960 (772) 584-2654 Admin@integritymetaisfl.com Joe Keene Admin@integritymetalsfl.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received David Eng PE-81377 PRI Construction Materials Technologies, LLC 05/25/2023 James R Wally, PE W- Validation Checklist - Hardcopy Received FL28113 R3 COI 26Qa IM100FF Dlvwood.odf Referenced Standard and Year (of Standard) Standard UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Year 2015 2006 Florida Licensed Professional Engineer or Architect FL28113 R3 Eauiv 1897-2015 eauiv letter.odf Method 1 Option D h4s://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgseOW WJsQVE.. 1 /28/2022 Florida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved Summarvof Products 06/09/202.1 b6/10/2021 06/15/2021 08/10/2021 Page 2 of 2 FL* Model, Number or Name Description 28113.Y011 26ga (min) IM10OFF on 15/32" 269a (min) IM10OFF nailstrip panel on 15/32", plywood (min) plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL28113 R3 II 26ga IM100FF Dlvwood.Ddf Approved for use outside HVHZ: Yes Verified By: David Eng, PE81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-108.5 Evaluation Reports Other: -108.5 PSF @ 5" oc and w/self-adhering FL28113 R3 AE 26ga IM100FF Dlvwood.Ddf underlayment i -78.5 PSF @ 10" oc Created by Independent Third Party: Yes 28113.2 02 1 29ga (min) IM36TR on 15/32" plywood 29ga (min) IM36TR exposed fastener ag panel on 15/32" plywood (min) Limits of Use Installation Instructions Approved for use in HVHZ: No F1_28113 R3 II 29aa IM36TR olvwood.odf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-146 Evaluation Reports Other: 146psf with 9"-9"-9"-9" fastener pattern @ 12" o.c, i 1`1_28113 R3 AE 29ga IM36TR DlvwoodPdf 86psf with 9"-9"-9"-9" fastener pattern @ 24" o.c. Created by Independent Third Party: Yes 28113.3 03 126ga (min) IM36PBR on 15/32" 26ga (min) IM36PBR exposed fastener PBR panel on 15/32" plywood plywood (min) Limits of Use Installation Instructions Approved for use in HVHZ: No FL28113 R3 1I 26ga 'IM36PBR olywood.Ddf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-119.5 Evaluation Reports Other: 119.5psf with 12"-12"-12" fastener pattern @ 12" FL28113 R3 AE 26ga IM36PBR alvwood.odf o.c. i 71psf with 12"-12"-12" fastener pattern @ 24" o.c. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275 (1), Florida Statutes, effectiveOctober1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card safe . https://www.floridabuilding.org/pr/pr_app_dtl:aspx?param=wGEVXQwtDgseOWWJsQVE.. 1 /28/2022 �i INTEGRITY METALS. Architectural Fabrication IM10OFF 26ga (min) 16" wide (max) nailstrip panel over 15/32" plywood Product Description: Nailstrip panel with 16" maximum panel width, and nominal rib height of 1 ". Product Material: 26ga (min) steel. Corrosion resistance per FBC 1507.4.3 where required Fastener: #10 x 1" low profile fastener. Larger diameter and longer length fasteners are acceptable. Stainless fasteners are acceptable. Compliant with FBC 1506.6 where required. Substrate/Deck:15/32" (min) plywood or1/a" (min) thick wood plank (min S.G. of 0.42). Max. Allowable Loads & Installation Requirements: Method A: 78.5 psf 'I Install fasteners every other hole (±10" o.c.) Method B:108.5 psf I Use self -adhering underlayment and install fasteners every hole (±5") Factor of Safety of 2.0 applied to calculate allowable loads. METHOD A FEMALE LEG SNAPS --- ` ONTO MALE LEG n � #10 FASTENER EVER OTHER HOLE (±10" O.C.) Evaluated By: David Eng, PE I Timberlake Cove, LLC 1317 Edgewater Or Ste 2339 I Orlando FL PE Lic. No: 81377 I CA Lic. No: 33344 .www.TimberLakeCove.com METHOD B J� FEM1ALE LEG SNAPS ONTO MALE LEG PANEL INSTALLED OVER SELF -ADHERING UNDERLAYMIENT 410 FASTENER EVERY HOLE - O.C.) \�11111111/��� o.• ►GENSF • '.0 No. 81377 STATE OF Z ��� 1VAl. �\ 11111111 DigiW J signed by David E Eng ✓A� Cdnfa!Wnfo: ✓ti'� "" �- dpvij;jg@dmbedakacove.wm Date�;2021.D6.0616:40:10-04' This item has been digitally signed and sealed by D.E. Eng, PE, on the date indicated. Printed copies of this document are not considered signed and sealed and the signature must- be verified on any electronic copies Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020,1504.3.2 (non-HVHZ).as required by FL Rule 61620-3, method 1, D; subject to the exclusions/limitations noted below. Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Panel Accessories: The manufacturer does not require the use of closures, sealants, butyl, or other similar accessories between bottom edge of panel and drip edge, or in other locations. The use of closures and sealants may be advisable in some cases, however that decision is the discretion of the project owner and the installer. Technical Documentation: This product has been tested to the following standards by_nowIntertek Testing (TST 1527). UL5801UL1897: report 17726.05-450-44 (used with permission) and.K4846.01-450-44. Design Process: Compare the maximum allowable loads on page 1 to the ASD uplift pressures for the project to determine sufficiency and installation requirements. Alternatively, as an option, the load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load. tables are based on ASCE 7-16. Use of these tables assumes that the structure is: Enclosed and conforms to wind-borne debris provisions and is a regular shaped building and is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: I David Eng, PE and Timberlake Cove, LLC do not have, nor will they acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will they acquire, a financial interest in any other entity involved in the approval or testing process of the product. Exclusions and Limitations: Design of deck and roof structure (to include deck attachment) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. Static water leakage is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61 G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based a:n this evaluation report. This report is limited solely to,documenting compliance with Rule 61 G20-3, and makes no express or implied warranty regarding performance of this product. Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 45° Have a mean roof height of 30 feet or less FL28113.1: 26aa IM10OFF on 15/32" Mvwood Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A. A, Zone 2: A A A A A B Zone 3: A A A A B3 B Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof less than 70, hip roof with max slope.of 450, or gable roof with slope between 200 and 45° Have a mean roof height of 30 feet or less FL28113.1: 26aa IM100FF on 15/32" Dlvwood Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A Zone 2: A A A A A A�GT'� Zone3: A. A A -A Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 45° Have a mean roof height of 30 feet or less FL28113.1: 26aa IM10OFF on 15/32" Divwood Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A B B B Zone 2: A B , B Zone 3. 1K'B. 3.6' ` k . Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with max slope of 45°, or gable roof with slope between 200 and 450 Have a mean roof height of 30 feet or less FL28113.1: 26aa IM100FF on 15/32" Dtvwood Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A _ A, A BBB: Zone 2: A A B B Zone 3: A OPTIONAL ENGINEERING LOAO TABLES Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed forthe project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. .Contact the manufacturer for further information, or consult a licensed design professional. Application: There are conservative assumptions used in combining scenarios for these load tables for cases when the required design load is unknown. The maximum allowable loads for this product are shown on page 1 of this approval. If the required allowable design loads are known, and the required design loads are less than the allowable load of the product, then the product is sufficient for use, and these optional load tables can be ignored. If the required design loads are NOT known, then the appropriate load table here may be used. These optional toad tables are subordinate to the max allowable loads shown on page 1 (they are merely one conservative application of those loads). In no case shall these load tables be interpreted to restrict the application of this product more than the max allowable loads shown on page 1. The max allowable loads shown on page 1 are the controlling design data for this product; NOT these optional load tables. M i `•, 2 2 3 �\ 1 1 2 2 \2 2 1Z 2 3 a i / 2 2 2 3 a 1 1 2 2 a 32 a F- J . L ulo I3I onnc —�J a Lt a: 10%OF LEAST HOIZONTAL DIMENSION OR OAh. WHICHEVER IS SMALLER. BUT NOT LESS THAN EITHER 41; OF LEAST HORIZONTAL DIMENSION OR 3FT kUMJ. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE ROOF ZONES FOR GENERIC BUILDING