Loading...
HomeMy WebLinkAboutConstruction Drawing VOIDGENERAL NOTES 1. THE CONTRACTOR AND TRADES SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING ANY WORK. THE CONTRACTOR SHALL NOTIFY KMA ENGINEERING OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO THE START OF ANY CONSTRUCTION. COMMENCING WORK MEANS ACCEPTANCE OF ALL CONDITIONS. KMA ENGINEERING WILL NOT BE RESPONSIBLE IN ANY WAY FOR CORRECTION OR MODIFICATION TO THE WORK. 2. ALL WORK SHALL CONFORM TO FBC 7TH EDITION (2020) RESIDENTIAL AND ALL APPLICABLE NATIONAL & LOCAL CODES. CONTRACTOR IS ADVISED TO CONSULT WITH KMA ENGINEERING PRIOR TO CONSTRCUTION TO DISCUSS THE REQUIREMENTS OF: ALL SUCH APPLICABLE AUTHORITIES. 3. DO NOT SCALE THE DRAWINGS. DIMENSIONS ARE PROVIDED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESOLVING ANY DISCREPANCIES PRIOR TO COMMENCING/CONTINUING WORK. 4. INSTALL ALL EQUIPMENT AND PRODUCTS IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS AND INSTRUCTIONS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL RELEVANT TRADES. 6. THESE DRAWINGS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "FOR CONSTRUCTION" AND SIGNED & SEALED BY THE ENGINEER OF RECORD. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AL[ NECESSARY PERMITS PRIOR TO CONSTRUCTION. THIS INCLUDES ANY AND ALL RELEVANT FEDERAL, STATE, AND LOCAL AUTHORITIES. PLAN VIEW DESIGN CRITERIA (FBC 2020) WIND SPEED = 160MPH Vult RISK CATEGORY = I EXPOSURE = D ENCLOSURE = OPEN IMPORTANCE FACTOR (ASCE7) = 0.77 RESULTANT WIND PRESSURE = 40.96 PSF REBUILT TO " I xG COMP 51TE DECKING ATTACH w/ (2) # I Ox3 5.5. DECK 5C EW5 EACH 5TKI GER TEELS LLTIEADSAHR ROD THRU-BOLT (2) 2xI P.T. BENTS (B HINLZ I'I LI NG) AERIAL MAP 2x 10 P.T. CAP BOARD ATTACH TO EACH STRINGER END w/ S) # I Cx3" 5.5. DECK I11N� _ _ — STRUCTURE JUST ABOVE GRADE EXISTING GRADE +I a DOCK SECTION "A -All SCALE: 1 :30 2x 10 P.T. STRINGERS I G O.C. I /2" BEYOND BENT ATTACH CAP BOARD ATOP BENT A5 STRINGER 2x P.T. UPRIGHT (2xG min. w/ (4) # I Ox3" DECK SCREWS Into BENT * (3) same Into STRINGER SCALE: O a� — ATTACH EACH STRINGER TO CAP — BOARD w/ (4) # 10 x3" DECK SCREWS 2x 10 CAP BOARD 2 1 /2" BEYOND BENTS 2x 10 CAP BOARD ABOVE BENT ON 2 51DE5 03S VA 0\ CONSTRUC-F ON Dl�\' NG/ 1:2011 rm PLAN ATTACH CAP BOARD TO PILING w/ (4) # 10 x3" DECK SCREWS 1 21-01I a III III 8" BUTT PILING w/ I H DPI 51-EEVE III CUT DENT8" BUTT HEIIGHT II III III (EXISTING)® III I I I III - III III III III III III III III III III III � I III III II ((� 2x P.T. UPRIGHT (2xG min.) w/ (4) # I Ox3" �/- 5.5. DECK SCREWS I I I I I I Into BENT * (3) same III Into 5TRINGER/CAP III / BOARD I I I I I 2x 10 STRINGERS _ @ I G" O.C. (2) 2x 10 P.T. BENTS ATTACHED TO PILING w/ (2) 5/8" 5.5. ATR THRU BOLT u I xG COMPOSITE DECKING Attach w/ (2) #8x2-1 /2" 55 Deck Screws every stringer Edcge of decking F ,jsh w/ cap board Imo./ L I\J /< AW NGS Docks . Decks Seawalls -Boat Lifts Chris Pinson 73-IM7 cp irdoc ks(ti gmail.com www.ind iiinriverd(,cks.coni KMA NGINEERING & SURVEYING, LLC. 60 ROYAL PALM POINTE, SUITE #401 VERO BEACH, FL 34960 PHONE: (772) 569-5505 FBPE C.O.A. # 33705 REVISIONS: BY: I DATE: I COMMENT: 0 O O LO O N i) O O o U Q' N Q Y C) CY) C O C U) N U o Lu - 0 .M U ZO � RECE D Q VV 1 2021 �_ U) E >,� cis M W u Lucid ty m0 Perm U �LL h— o� O Cr M LL � Na O U 1— Y Q Cl) W o 0 = U) 2 W J Z Y -0 H a Q M Q J J z U Qo o z Q ry w w J U > W � Cn Z Q z Q z n Z 0 ' 2 1[11 % NCB 41060 � rATE I- m� �� �� as K., DAVID S. KNIGHT, PE FLORIDA LICENSE No. 41060 10/1 /21 DEP FILE No.: TBD DRAWN BY: DRAWN BY CHECKED BY: CHECKED BY DATE: 10/2D/21 CAD I.D.: WHALEY SHEET TITLE: SHEET NUMBER: 1