HomeMy WebLinkAboutpeel and stick for shingles 2020 codeFlorida Building Code Online
Page 1 of 2
BCIS Nome Log In 1 User Registration i Hot Topics i Submit 5wcharge
r Product Approval
IUSER: Pubic llser
IREOfflow M,
Stats & Facts Publications Contact Us BCIS Site MaP 1 Links Search ii
Product Approval Menu > Product or Application Search > Application Lest > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL2569-R20
Revision
2020
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@soprema.ca
Mare -Etienne Mathieu
me math ie u @soprema. ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memath ieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert J. M. Nieminen
PE-59166
UL LLC
04/10/2023
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL2569 R20 COI 2020 01 COI NIEMINEN,pdf
Standard
ASTM D1970
ASTM D4798
ASTM D6163
FM 4474
FRSA/TRI Sixth Edition
UL 1897
Year
2015
2011
2015
2011
2018
2012
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsKQFEnckB 1...
1 / 12/2021
Florida Building Code Online
Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
09/19/2020
Date
Validated
09/22/2020
Date
Pending FBC Approval
09/29/2020
Date
Approved
12/15/2020
Date
Revised
12/16/2020
Summary of Products
FL #
Model, Number or Name
Description
2569.1
Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL2569 R2Q II 2020 09 17 FINAL ER FL2569-R20. df
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
Evaluation Reports
FL2569 R20 AF 2020 09 17 FINAL ER FL2569-R20. df
Created by Independent Third Party: Yes
design pressure noted herein pertains to underlayment
systems used beneath adhesive -set tile systems. Refer to ER
Section 5.6.4 for details.
Back Mext
Contact Us:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovrieht 2007-2013 State of Florida :: Pnvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail If you have any questions, please contact 850.487.1395. *Pursuant to Sectlon 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a hcensee under Chapter 455, F.S., please
click here .
product Apprnvat Accepts:
® ® ® dhsk
Credit Card
Safe
https:llwww.floridabuilding.orglprlpr app_dtl.aspx?pararn=wGEVXQwtDgsKQFEnckB1... 1/12/2021
RESISTO
March 41h, 2020
To whom it may concern:
This letter is to serve as confirmation of the following product approval for the Florida Building
Code FL17084 for low slope roofing and FL2569 for steep slope underlayments as well as the
Miami -Dade Notice of Acceptance No.: 15-1123.06.
The RESISTO LB1236 is manufactured by RESISTO, a division of Soprema Inc., and is
privately labeled under the following other brand name: TRI-BUILT Sand-R SIA.
Should there be any further questions, please contact us directly.
Sincerely,
Matthew Rucinski
Inside Sales & Technical Support
Direct: (855) 227-7850
mrucinski@resistaus
fisOPM—w RESISTO HE kJ K DIZ W
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION O.
Soprema, Inc. Evaluation Report S18010.06.09-R18
1640 rue Haggerty
FL2569-R20
Drummondville, Qu6bec J2C 5P8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 18: 09/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the products) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
.'• - c -�'.-c`J�'�'" The facsimile seal appearing was authorized by Robert
•: ��
_=�.,_.-,.
Nieminen, P.E. on 09/17/2020. This does not serve as
""='"
Florida Registration No. 59166, Florida DCA ANE1983
".�s�:.,:;;.:"' an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
1. SCOPE.
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema,
have demonstrated compliance with the
following sections of the 7' Edition (2020) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject
to the Installation Requirements and Limitations / Conditions
of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2012
1507.1.1, 1507.2.4, 1S07.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2 / R905.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entibf
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12 (OH)
S11150.05.09-R2
10/05/2010
ERD (TSTB049)
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TR104-12(MS)
543530.02.14-1-R1
02/21/2014
ERD(TST6049)
ASTM D1970(BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 (QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD tTST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8S20.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-D (CER1592)
HVHZ Compliance
18-0329.03
06/29/2018
iCC-ES (EVi2396)
2015 113C Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SO PC-18-002.05.19.A
05/31/2019
MEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-Ol.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-S0PC-19-S5UDL-04.A
03/12/2020
PRI (TST5878)
ASTM D1910 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
NEMO ETC, LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18; 09/17/2020
Page 2 of 8
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4,16
ONEMO I etc.
PRODUCT
Product
Material
Plant(s)
Description
p
Standard
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths, 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM 01970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, 58S modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM 01970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self --adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB12444
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report S18010.06.09-R18
Certificate of Authorization#32455 7TR EDITION (2020) FSC NON-HVHZ EVALUATION FL2569•R20
Soprema Roof Undedayments Revision 18: 09/17/2020
Page 3 of 8
ONEMOletc.
Product
Material
Plant(s)
Description
Standard
4.17
Colphene FIR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties)-
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction-
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.S Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile
Metal
Slate or
Wood
Asphalt
(1597.3)
Slate -Type
Underlayment
Shingles
Shingles
8
Mechanical
Adhesive-
Panels
Shingles
Shingles
(1507 2)
Attach
Set
(1507.4)
(1507.51
(1507.7)
(1597.8)
shakes (1507.9)
Yes
Yes
Yes
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
point strips, 1507.1.1.3
lioint strips, 1507.1.13
See 5.G.1
/ R905.1.1.3]
/ R905, 1.1.3]
Lastobond Shield / Pro HT-N
Yes
Yes
/ RESISTO SA SMOOTH PLY
Yes
No
No
No
No
Yes
(joint strips, 1507.1.1.3
(joint strips, 1507.2.1.3
40
/ R9a5.11.31
/ R905.1.1.3]
Yes
Yes
Lastobond shield HT / Pro
Yes
Na
No
Yes
Yes
Yes
Qn;nt strips, 1507.1.13
(joirt scrips,lsoz1.1.3
HT-S
/ 11905.1.1.3j
/ R905.1.13j
Yes
Yes
EnvireShield
Yes
No
No
Yes
Yes
Yes
(joint strips, 1507.1.13
Galntstr;p5,1507.1.1.3
/ R90S.1.1.3]
/ 11905.1.1.3j
Yes
Yes
Lastobond Eaves Protection
Yes
No
No
No
No
Yes
Quint strips, 1507-11.3
Quint strips, 1507.1.13
Sheet / Lastobond 195
/ R905-1-13)
/R905.1.13)
Lastobond ECO / RESISTO
LB1235, Grip -Rite Eave &
Yes
Yes
Valley Protector /TopShield
Yes
No
No
No
No
Yes
Uoiotstrips, 1507.1.1.3
(jnintwips1507.1-1.3
ICE& WATER DEFENDER/
/R9os.1.1.31
/R903.1.1.3}
RESISTO LB1244
Yes
Yes
Lastobond smooth Seal HT /
Yes
No
No
Yes
Yes
Yes
(joint strips, 1507.1.1.3
{joint strips, 15071.1.3
Grip -Rite Smooth Seal HT
/R905.1.13)
/R905-113i
Yes
Yes
ColpheneFRGR
Yes
Yes
No
No
No
Yes
(joint strips,1507.1.1.3
Ijointstrips, 1507.1.1.3
/ R905.1.1.3)
/ 11905.1.13)
NEMO ETC, LLC Evaluation Report S18010.06.09-1118
Certificate of Authorization #32455 7t" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 1S: 09/17/2020
Page 4 of 8
ONEMO I etc.
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Lastobond TU HT
Dupont "Tile Bond— Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polyset® AH-160"
FL6332 �
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENT5
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type
Primer
Materials)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
plywood, OSB or Southern Yellow Pine
HT-N, RESISTO SA SMOOTH PLY
Deck /
D41, Elastocol Stick,
(SYP)
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero
ASTM D41
structural concrete
Lastobond Pro HT-S,
Enviro5hield, Lastobond TU HT,
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Lastobond Eaves Protection
self-
Insulation
Stick Zero
Fiber Roof Board
Sheet, Lastobond 195, Lastobond
adhering
ECO, RESISTO LB1236, Grip -Rite
Eave & Valley Protector,
TopShield ICE & WATER
Base Sheet
{Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
DEFENDER, RESISTO LB1244,
Stick Zero
G
Lastobond Smooth Seal HT or
Grip -Rite Smooth Seal HT
Deck /
(Optional) ASTM
Plywood
D41
sheathing
ASTM D41
structural concrete
Colphene FR GR
self -
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
adhering
adhering
insulation
Zero
Fiber Roof Board
(Optional) Elastocol
ASTM D226, Type II felt or Modified Sopra-
Base Sheet
Stick Zero
G
RESISTO LB1236, Grip -Rite Eave
self-
Existing
EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
& Valley Protector or TopShield
mineral -surfaced or film -surfaced roof
ICE & WATER DEFENDER
adhering
substrate
PRIMER
PRIMER
underlayment*
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eove &
Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours_
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or 0513 prior to installation of the
self -adhering underlayment
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance,
NEMO ETC, LLC Evaluation Report 518010.06.09-R18
Certificate of Authorization #32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZO
Soprema Roof Underlayments Revision 19: 09/17/2020
Page 5 of 9
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but —for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocoi Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, self adhered.
#3 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, self adhered.
#4 Maximum Design Pressure = -150.0 psf:
Deck: Min. 1S/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath the roof systems carry a Maximum Design
Pressure of -45 psf.
NEMO ETC, LLC Evaluation Report S18010.06.09-R18
Certificate o}Authorization #32455 7- EDITION (2020) FBC NON-HVH2 EVALUATION FL2569•1320
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 6 of 8
ONEMOletc.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay hoof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified 5opra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch D.C. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover
Maximum
Underlayment
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip-
Mechanicaily
30
Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244
attached
Adhesive -set tile roof
30
Lastobond TU HT
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Mechanically
90
Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT
attached
Lastobond TU HT or Colphene FR GR
Mechanically
attached
180
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
6:12
followed by 8 tiles high on slope, as shown below)
i
Lastobond TU HT
4
Lugged
NEMO ETC, LLC Evaluation Report 518010.06.09-1118
certificate of Authorization #32455 7- EDITION (2020) FBC NON-1 EVALUATION FL2569-1120
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 7 of 8
ONEMOletc.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
5:12
Colphene FR GR
Lugged
Max. 10-tile stack
6:12
6. r
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -
adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires
priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a
reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley
Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE &
WATER DEFENDER, RESISTO LB1244 or Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type it felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications:
Limited to Lastobond TU HT or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florido
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
Refer to7.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS M
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations raving met codified material standards.
9. QUALITY AssuRANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report S18010.06,09-1118
Certificate of Authorization J#32455 7T" EDITION Q020i FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 8 of 8