HomeMy WebLinkAboutDuct Leakage Test ReportFORM R405-2017 Duct Leakage Test Report - Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit Number: Job Information E Builder: Community: Lot: Address: 6609 Deland Ave Unit: City: Fort Pierce State: FL Zip: 33951 Duct Leakage Test Results _ - I System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 _ 1318 _ Qn Total of all Total Conditioned systems Square Footage ❑ PASS ❑ FAIL Prescriptive Method cfm25 (Total) To qualify as "substantially leak free", Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed,- Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed ❑ YES(- 0.04 on) during testing? 0 NO (<=0.03On) ❑: Performance / ERI Method cfm25 (Out or Total) To qualify using this method, Qn must be not greater than the proposed duct leakage Qn specified -on Form R405-2017 or R40e-2017. Leakage Type selected on Form Qn specified on Form R405-2017 R405-2017 (Energy Cato) or R406-2017 (Energy Calc) or R406-2017 Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company, ; ' 1. F Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: Ri htSuite® Universal 2019 19.0.15 RSU15408 Ri ht-Ener ® Florida 2017 Section 405.4.1 Compliant Software Mar-13 Page 14 wriightsofY° 9 9 sr P Page 14 rwre�r a ,yy d LoadlRight Suitet2020\Ana\Jomilton Jovani.rup Calc = MJ8 Front Door faces: N Reference Home Characteristics Jomilton Jovani Loza 6609 Deland Ave Fort Pierce, FL 33951 Above -grade Walls (Uo) Above -grade Wall Solar Absorptance Above -grade Wall Infared Emittance Basement Walls (Uo) Above -grade Floors (Uo) Slab Insulation R-Value Ceilings (Uo) Roof Solar Absorptance Roof Infared Emittance Attic Vent Area (fF) Crawlspace VentArea (ft2) Exposed MasonryFloorArea (ft2) Carpet & Pad R-Value Door Area (ftz) Door U-Factor North Window Area (ft2) South Window Area (ftz) East Window Area (ftz) West Window Area (ft2) Window U-Factor Window SHGC (Heating) Window SHGC (Cooling) ACH50 Internal Gains * (Btu/day) Water'heater gallons per day Water Heater set point temperature Water heater efficiency rating Labeled Heating System Rating and Efficiency Labeled Cooling System Rating and Efficiency Air Distribution System Efficiency Thermostat Type Heating Thermostat Settings Title: Jomilton Jovani FLBase2017 0.084 0.75 0.90 n/a n/a 0.0 0.030 0.75 0.90 4.38 n/a 262.94 2.0 0.00 n/a 0.00 44.71 44.71 44.71 0.400 0.2169 0.2169 7.00 61578 60.00 120.00 0.94 HSPF = 8.2 SEER = 14.0 0.88 Manual 72.0 (All hours) TMY City: FL —Fort —Myers -Page