HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Builder Name:
Street: 6609 Deland Ave
Permit Office:
City, State, Zip: Fort Pierce, FL 33951
Permit Number:
Owner: Jomilton Jovani Loza
Jurisdiction:
Design Location: FL, Vero Beach Municipal AP
County: Palm Beach (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall types (1476 ft2)
Insulation (R) Area (ft2)
2. Single family or multiple family Single -Family
a. Blk wall, stucco ext, r-5 ext bd
5.0 1201.18
b. Firm wall, stucco ext, r-13 cav i
13.0 274.95
3. Number of units, if multiple family 1
c. N/A
4. Number of bedrooms 3
d. N/A
10. Ceiling types (1315 ft2)
Insulation (R) Area (ft2)
5. Is this a worst case? No
a. Attic ceiling, asphalt shingles
30.0 1314.71
6. Conditioned floor area above grade (W) 1317.92
b. N/A
Conditioned floor area below grade (ft2) 0
c. N/A
7. Windows 179 ft2 Description Area ft2
( ) p ( )
11. Ducts R Area (ft2)
a Sup: Entire House At, Ret: Entire House At, AH: Entire House 6.0 205.26
a. U-Factor: Sgl Impact, 1.070 103.11
b,
SHGC: 0.65
b. U-Factor: Dbl Impact, 0.650 40.80
12. Cooling systems
kBtu/hr Efficiency
SHGC: 0.22
a.Split air conditioner
28.8 SEER: 16.0
c. U-Factor: Dbl Impact, 0.390 34.92
b•
SHGC: 0.24
13. Heating systems
kBtu/hr Efficiency
d. U-Factor:
a.Electric strip
27.3 AFUE: 100.0
SHGC:
b.
Area Weighted Average Overhang Depth: 4.582 ft
14. Hot water systems
Area Weighted Average SHGC: 0.472
a.Electric conventional (50 gal)
Cap: 50 gal
EF: 0.91
8. Floor types (1314.71 ft2) Insulation (R) Area (ft2)
b.Conservation features
a. Bg floor, heavy damp soil, on gr 0.0 1314.71
(None)
b. N/A
c. N/A
15. Credits Ceiling Fan
Glass/Floor area: 0.136 Total Proposed Modified Loads: 51.01
PASS
Total Baseline
Loads: 51.30
I hereby certify that the plans and specifications covered by
Review of the plans and specifications
this calculation are in compliance with the Florida Energy
covered by this calculation indicates
compliance with the Florida Energy'
p�s'O
Code. /[�Ju�
�Y'
Code. Before construction is completed,
a7 j s
PREPARED BY:
this building will be inspected for
compliance with Section 553.908
?�
DATE: 03/13/2020
Florida Statutes.
E
I hereby certify that this building, as designed, is in
COS
compliance with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50 (R402.4.1.2).
2020-Mar-13 11:42:18
wrightsoft6 RightSuite® U niversal 2019 19.0.15 RSU15408 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page 2
ate�t•aeat�. yr Yw.q ...d Load\Right Suitet2020Wna\Jomilton Jovani.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Building Input Summary Report
PROJECT
Title: Bedrooms: 3
Address type:
Street address
Building Type: FLAsBuilt Bathrooms: 2
Lot#:
Owner: Jomilton Jovani Loza Conditioned Area: 1318
Block/Subdivision:
# of Units: 1 Total
Stories: 1
Platbook:
Builder Name: Worst Case: No
Street:
6609 Deland Ave
Permit Office: Rotate
An le: 0
Countv:
Palm
Beach
Jurisdiction: Cross Ventilation: No
City, State, Zip:
Fort Pierce, FL 33951
Family Type: Single -Family Whole House Fan: No
New/Existing: New Plans) Terrain: Suburban
(From
Year Construct: Shielding:
Suburban
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site
Zone 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, Vero Beach Municipal AP FL -Fort -Myers -Page
2 43 91
70 75
416
59 Low
BLOCKS
# Name Area
Volume
1 Entire House 1317.92 ft2
12388.46 ft3
SPACES
# Area Volume
Kitchen Occupants Bedrooms Infil ID Finished
Cooled Heated
1 Master Bathroom 104.65 ft2 983.70 ft3
No 0
0 1
Yes
Yes Yes
2 WIC 52.88 ft2 497.02 ft3
No 0
0 1
Yes
Yes Yes
3 Master Bedroom 273.78 ft2 2573.51 ft3
No 0
1 1
Yes
Yes Yes
4 Kitchen 163.63 ft2 1538.07 ft3
Yes 0
0 1
Yes
Yes Yes
5 Bedroom 2 192.99 ft2 1814.09 ft3
No 0
1 1
Yes
Yes Yes
6 Bath 53.55 ft2 503.34 ft3
No 0
0 1
Yes
Yes Yes
7 Hall 33.57 ft2 315.52 ft3
No 0
0 1
Yes
Yes Yes
8 Bedroom 1 174.61 ft2 1641.33 ft3
No 0
1 1
Yes
Yes Yes
9 Livingg Dining 253.47 ft2 2382.64 ft3
No 4
0 1
Yes
Yes Yes
10 A/C 14.81 ft2 139.24 ft3
No 0
0 1
Yes
Yes Yes
FLOORS
(Total Exposed Area =1315 sq.ft.)
✓ # Floor Type
Space Perimeter R-Value Area
U-Factor
Tile Wood Carpet
1 Bg floor, heavy damp soil, on grade depth, tile f
Master Bathroom 9 ft
0 103.91 ft2
1.358
1.0 0 0
2 Bg floor, heavy damp soil, on grade depth, tile f
WIC 0 ft
0 52.50 ft2
1.358
1.0 0 0
3 Bg floor, heavy damp soil, on grade depth, tile f
Master Bedroom 33 ' ft
0 273.78 ft2
1.358
1.0 0 0
4 Bg floor, heavy damp soil, on grade depth, tile f
Kitchen 14 ft
0 163.63 ft2
1.358
1.0 0 0
5 Bg floor, heavy damp soil, on grade depth, tile f
Bedroom 2 28 ft
0-191.25 ft2
1.358
1.0 0 0
6 Bg floor, heavy damp soil, on grade depth, tile f
Bath 6 ft
0 53.19 ft2
1.358
1.0 0 0
7 Bg floor, heavy damp soil, on grade depth, tile f
Hall 0 ft
0 33.57 ft2
1.358
1.0 0 0
8 Bg floor, heavy damp soil, on grade depth, tile f
Bedroom 1 29 ft
0 174.61 ft2
1.358
1.0 0 0
9 Bg floor, heavy damp soil, on grade depth, tile f
Living/Dining Dining 10 ft
0 253.47 ft2
1.358
1.0 0 0
10 Bg floor, heavy damp soil, on grade depth, tile f
A/C 0 ft
0 14.81 ft2
1.358
1.0 0 0
ROOF
Roof Gable Roof
Solar SA
Emitt
Emitt Deck Pitch
✓ # Type Materials
Area Area Color
Absor. Tested
Tested Insul. (deg)
1 Hip RoofAsph
1424 ft2 Medium 0.75 No
0.90
No 0 23
ATTIC
f # Type Ventilation
Vent Ratio 0 in
Area RBS
IRCC
1 Full attic Vented
150 1314.71 ft2 N
N
202o-Mar-13 11:42:18
wrightsofte Rig htSuite®Universal 201919.0.15RSUIS408 Right-Energy®Flodda2017 Section 405.4.1Compliant Soflware Page
awrrrew�s. ®.ot� d LoadlRight Suite12020Wna\Jomilton Jovani.rup Calc = MJ8 Front Door faces: N
Fr1RAA PAnR_gn17
CEILING
(Total Exposed Area = 1315 sq.ft.)
✓
#
Ceiling Type
Space
R-Value U-Factor
Area
Framing Fraction Truss Type
1
Attic ceiling, asphalt shingles roof Master Bathroom
30
0.032
103.91 ft2
0.10
-
2
Attic ceiling, asphalt shingles roof
W.I.0
30
0.032
52.50 ft2
0.10
-
3
Attic ceiling, asphalt shingles roof Master Bedroom
30
0.032
273.78 ft2
0.10
-
4
Attic ceiling, asphalt shingles roof
Kitchen
30
0.032
163.63 ft2
0.10
-
5
Attic ceiling, asphalt shingles roof
Bedroom 2
30
0.032
191.25 ft2
0.10
-
6
Attic ceiling, asphalt shingles roof
Bath
30
0.032
53.19 ft2
0.10
-
7
Attic ceiling, asphalt shingles roof
Hall
30
0.032
33.57 ft2
0.10
-
8
Attic ceiling, asphalt shingles roof
Bedroom 1
30
0.032
174.61 ft2
0.10
-
9
Attic ceiling, asphalt shingles roof
Livingg �Dining
30
0.032
253.47 ft2
0.10
-
10
Attic ceiling, asphalt shingles roof
A/C
30
0.032
14.81 ft2
0.10
-
WALLS
(Total Exposed Area = 1476 sq.ft.)
Adjacent
Cavity Width
Height
Sheathing
U- Frm. Solar
Below
✓
#
Omt To Wall Type
Space R-Value Ft In
Ft In
Area R-Value
Factor Frac. Absor.
Grade%
1
E
Exterior Blk wall, stucco Master Bathroom
0 8 9
9 5
82.3 ft2 5
0.125 0.22 0.60
0
2
-
Partition Frm wall, stucco Master
Bathroom
13 11 11
9 5
111.6 ft2 0
0.115 0.25 0.75
0
3
-
Partition Frm wall, stucco
W.I.0
13 2 6
9 5
23.5 ft2 0
0.115 0.25 0.75
0
4
E
Exterior BIk wall, stucco Master Bedroom
0 15 6
9 5
145.7 ft2 5
0.125 0.22 0.60
0
5
S
Exterior BIk wall, stucco Master Bedroom
0 17 2
9 5
161.0 ft2 5
0.125 0.22 0.60
0
6
S
Exterior BIk wall, stucco
Kitchen
0 14 0
9 5
131.6 ft2 5
0.125 0.22 0.60
0
7
S
Exterior Blk wall, stucco
Bedroom 2
0 12 9
9 5
119.8 ft2 5
0.125 0.22 0.60
0
8
W
Exterior BIk wall, stucco
Bedroom 2
0 15 0
9 5
141.0 ft2 5
0.125 0.22 0.60
0
9
W
Exterior Blk wall, stucco
Bath
0 5 9
9 5
54.0 ft2 5
0.125 0.22 0.60
0
10
N
Exterior Blk wall, stucco
Bedroom 1
0 8 11
9 5
83.4 ft2 5
0.125 0.22 0.60
0
11
NE
Exterior BIk wall, stucco
Bedroom 1
0 2 10
9 5
26.6 ft2 5
0.125 0.22 0.60
0
12
E
Exterior BIk wall, stucco
Bedroom 1
0 1 0
9 5
9.4 ft2 5
0.125 0.22 0.60
0
13
W
Exterior BIk wall, stucco
Bedroom 1
0 13 0
9 5
122.2 ft2 5
0.125 0.22 0.60
0
14
NW
Exterior Blk wall, stucco
Bedroom 1
0 2 10
9 5
26.6 ft2 5
0.125 0.22 0.60
0
15
N
Exterior Blk wall, stucco
Living Dining
0 10 5
9 5
97.5 ft2 5
0.125 0.22 0.60
0
16
-
Partition Frm wall, stucco
Living Dining
13 5 6
9 5
51.7 ft2 0
0.115 0.25 0.75
0
17
-
Partition Frm wall, stucco
A/C
13 9 5
9 5
88.1 ft2 0
0.115 0.25 0.75
0
DOORS
(Total Exposed Area = 21 sq.ft.)
Width
Height
✓
#
e
Omt Door Type
Space
P
Storms
U-Value Ft In
Ft In Area
1
N Door, mtl pur core type
Living Dining
None
0.290 3 0
7 0 21.0 ft2
WINDOWS
(Total Exposed Area = 179 sq.ft.)
Wall
Overhang Interior
✓
#
Omt ID Frame Panes
NFRC U-Factor SHGC Impact Area Depth
Separation Shade
Screening
1
Clear)
E 1 Metal Single�((ouble
Yes
1.070 0.65
Yes
7.4ft2 1 ft 7 in
2 ft 7 in Blinds 45°
outdoor
2
E 4 Metal Singlelear))
Yes
1.070 0.65
Yes
24.7ft2 1 ft 7 in
2 ft 7 in Blinds 45°
outdoor
3
S 5 Metal Singlelear
Yes
1.070 0.66
Yes
23.4ft2 10 ft 0 in
2 ft 7 in Blinds 45°
outdoor
4
S 6 Metal Low-E
Yes
0.650 0.22
Yes
40.8ft2 1 It 7 in
2 ft 7 in Blinds 45°
outdoor
5
Clear)
S 7 Metal Single�((()Uble
Yes
1.070 0.65
Yes
16.3ft2 10 ft 0 in
2 ft 7 in Blinds 45°
outdoor
6
W 9 Metal Singlelear
Yes
1.070 0.65
Yes
7.4ft2 1 ft 7 in
2 ft 7 in Blinds 45°
outdoor
7
N 10 Metal Singlelear
Yes
1.070 0.65
Yes
23.9ft2 1 ft7 in
2 ft 7 in Blinds 45'
outdoor
8
NE 11 Metal Low-E
Yes
0.390 0.24
Yes
7.9ft2 1 ft 7 in
2 ft 7 in Blinds 46'
outdoor
9
NW 14 Metal Low-E Double
Yes
0.390 0.24
Yes
7.9ft2 1 ft 7 in
z
2 ft 7 in Blinds 45°
outdoor
GARAGE
✓
#
Floor Area Ceiling
Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
0
INFILTRATION
Scopeo
SLA
CFM 50
ELA
EqLA ACHC
1
Wholehouse Blower Door
0.000180
619.4 34.07
63.97 0.23
3.00
HEATING SYSTEM
✓
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric stri
AFUE: 100.0 27.3 kBtu/hr
1
s s#1
COOLING SYSTEM
✓
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Split air conditioner
SEER: 16.0 28.8 kBtu/hr 970 cfm 0.70 1
sys#1
Ri htSuite® Universal RSU15408 Ri ht-Ener ®Florida2017 Section Compliant wirights�ftH 9 9 9Y P Page 4
AK&J a,""f-7 d LoadlRight Suite\20201AnaUomilton Jovani.rup Calc = MJ8 Front Door faces: N
CnOnn OAA= 7n47
HOT WATER SYSTEM
✓ # System Type Subtype Location EF Cap
Use
SetPnt
Conservation
1 Electric conventional
0.91 50 gal
60 gal
120 °F
None
DUCTS
Supply
--
----
Return--
Air
CFM 25 Percent
HVAC #
✓ # Location R-Value Area
Location Area Leakage Type
Handler
Out
Leakage QN
RLF
Heat Cool
1 Entire House At 6.0
205 ftz
Entire House At 12 ft' Default Leakage
Entire House
(Default)
6.00
1 1
TEMPERATURES
Programmable Thermostat: Y
Ceiling Fans:
Cooling [ X ]Jan [ X] Feb
[X] Mar
[ X] Apr
[ X] May [ X] Jun [ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct [ X] Nov
[ X] Dec
Heating [ X ]Jan [ X] Feb
[X] Mar
[ X] Apr
[X]My a [ X] Jun [ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct [ X] Nov
[ X] Dec
Venting [ X ]Jan [ X] Feb
IX] Mar
[ X] Apr
[X]May [ X] Jun [ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct [ X] Nov
[ X] Dec
Thermostat Schedule: Florida Building Code, 6th Edition Hours
Schedule Type
1
2
3 4 5 6
7
8
9 10
11
12
Cooling (WD) AM
75
75
75 75 75 75
75
75
75 75
75
75
PM
75
75
75 75 75 75
75
75
75 75
75
75
Cooling (WEH) AM
75
75
75 75 75 75
75
75
75 75
75
75
PM
75
75
75 75 75 75
75
75
75 75
75
75
Heating (WD) AM
72
72
72 72 72 72
72
72
72 72
72
72
PM
72
72
72 72 72 72
72
72
72 72
72
72
Heating (WEH) AM
72
72
72 72 72 72
72
72
72 72
72
72
PM
72
72
72 72 72 72
72
72
72 72
72
72
2020-Mar-1311:42:18
wrightsaft° Right -Suite® Universal 2019 19.0.15 RSU15408 Right -Energy® Florida2017 Section405.4.1 Compliant Software Page
areare�aerts. � a d Load\Right Suite\20201Ana\Jomilton Jovani.rup Calc = MJ8 Front Door faces: N