HomeMy WebLinkAboutNOA # 16-0920.09MIAMI-DADE COUNTY
KIM ' PRODUCT CONTROL SECTION
amin11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.my/economy
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Slateline® Shingle
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or'manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1022.19 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
APPROVED
jltoe
Goo
NOA No.: 16-0920.09
Expiration Date: 03/08/22
Approval Date: 02/09/17
Page 1 of 4
It
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Asphalt Shingles
Material:
5-Tab
Deck Type:
Wood
SCOPE:
This approves GAF Slateline® as manufactured by GAF as described in this Notice of Acceptance, designed to comply
with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured by
Applicant Dimensions
GAF Slateline® Shingle 17" x 40"
MANUFACTURING LOCATION:
1. Mt. Vernon, IN
Test Product
Specifications Description
TAS 110 Fiberglass reinforced heavy weight asphalt roof
shingle, with 5-tabs.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
PRI Asphalt Technologies
GAF-142-02-01
TAS 100
07/31/06
Underwriters Laboratories
4787544124
ASTM D 3462
09/08/16
Underwriters Laboratories, Inc.
06CA35251
TAS 107
06/28/06
Underwriters Laboratories, Inc.
06CA35251
ASTM E 108
10/18/06
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA INo.: 16-0920.09
Expiration Date: 03/08/22
Approval Date: 02/09/17
Page 2 of
0
INSTALLATION:
1. Shingles shall be installed in compliance with Roofing Applications Standard RAS 115.
2. Flashing shall be in accordance with Section 9.3 Option `B" (step-flashings) of Roofing Applications Standard
RAS 115.
3. The manufacturer shall provide clearly written application instruction.
4. Exposure and course layout shall be in compliance with Detail "A", attached.
5. Nailing shall be in compliance with Detail `B", attached.
LABELING:
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
NOA No.: 16-0920.09
CMIAMI-D�AE COUNTY Expiration Date: 03/08/22
Approval Date: 02/09/17
Page 3 of 4
RAKE
DETAIL A
COURSE LAYOUT
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
15 1/2" (394mm) -16 112" (41
7 1/2" (191mm) j 8 1/2"
0 0 0 0 0
EXPOSURE
9"(229mm)
7 1!2" (191mm)
noina 91/16
Nailing Pattem
END OF THIS ACCEPTANCE
CMIIAMI-D�AE COUNTY
...• •
JSURE
NOA No.: 16-0920.09
Expiration Date: 03/08/22
Approval Date: 02/09/17
Page 4 of 4