HomeMy WebLinkAboutEPL Display Card 8-4-14ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 60
The lower the EnergyPerformance Index, the more efficient the home.
, Hutchinson Island, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0
3740.00 ft2
b. Frame - Wood, Exterior
R=19.0
2569.60 ft2
3. Number of units, if multiple family
1
c. Frame - Wood, Adjacent
R=19.0
546.00 ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
Yes
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2693.00 ft2
6. Conditioned floor area (ft2)
4858
b. N/A
R=
ft2
7. Windows" Description
Area
c
R_
z
ft2
a. U Factor: Dbl, U=0.43
1390.90 ft2a.
11. Ducts
Sup: Attic, Ret: Attic, AH: Attic
R
6 1005
SHGC: SHGC=0.20
b. Sup: Attic, Ret: Attic, AH: AHU
6 933
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
42.0 SEER:16.30
SHGC:
b. Central Unit
42.0 SEER:16.30
d. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
21.1
COP:1.00
Area Weighted Average Overhang Depth:
3.107 ft.
b. Electric Strip Heat
40.5
COP:1.00
Area Weighted Average SHGC:
0.200
8. Floor Types
Insulation
Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation
R=0.0
2536.30 ft2
a.
EF:
b. Floor Over Other Space
R=0.0
2248.00 ft2
c. N/A
R=
ft2
b. Conservation features
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �%_ Date: C6 I4
Address of New Home: 100 ZCS144 bo,&L COS City/FLZip: J$ FL 349S7-
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Level 1
Level 2
Level 3