HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Rincella Load Template Energy Calc 4 Builder Name: Gulick Construction Company Street: Permit Office: City, State, Zip: Hutchinson Island , FL , Permit Number: Owner: Rinicella Residence Jurisdiction: Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT 1. New construction or existing New (From Plans) 9. Wall Types (6855.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 3740.00 ft2 b. Frame - Wood, Exterior R=19.0 2569.60 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=19.0 546.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2693.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 2693.00 ft2 6. Conditioned floor area above grade (ft2) 4858 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(1390.9 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 1005 a. U-Factor: Dbl, U=0.43 1390.00 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 6 933 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.30 b. Central Unit 42.0 SEER:16.30 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency --d. U-Factor: N/A ft2 a. Electric Strip Heat 21.1 COP:1.00 SHGC: b. Electric Strip Heat 40.5 COP:1.00 Area Weighted Average Overhang Depth: 3.107 ft. Area Weighted Average SHGC: 0.200 14. Hot water systems 8. Floor Types (4784.3 sqft.) Insulation Area a. EF: 5.67815E26 a. Slab -On -Grade Edge Insulation R=0.0 2536.30 ft2 b. Conservation features b. Floor Over Other Space R=0.0 2248A0 ft2 c. N/A R= ft2 15. Credits CF, Pstat' Glass/Floor Area: 0.286 Total Proposed Modified Loads: 61.47 PASS Total Standard Reference Loads: 102.81 /1�7�7 I hereby certify that the plans and specifications covered by Review of the plans and Y ©�ExAT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance nEG� i" with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 07/1/2014 CTL Consultants 772-882-5700 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. IE' t3 with - W OWNER/AGE T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Compliance requires a roof absorptance test in accordance with 405.6.2 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 9 PROJECT Title: Rincella Load Template Ener Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 4858 Lot # 2 Owner: Rinicella Residence Total Stories: 3 Block/SubDivision: Las Tortugas # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Gulick Construction Company Rotate Angle: 90 Street: Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Hutchinson Island , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL,VERO_BEACH_MUN FL_VERO_BEACH_MUNI 2 45 90 70 75 299 64 Medium BLOCKS Number Name Area Volume 1 First Floor 2522 31523.7 2 Second Floor 2336 19348.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Breezeway 269 3228 No 0 1 Yes Yes Yes 2 Wine Room 174 2088 No 0 1 Yes Yes Yes 3 Dining 291 3489 No 0 1 Yes Yes Yes 4 Kitchen 190 2280 Yes 2 1 No Yes Yes 5 Library 225 3285 No 0 1 Yes Yes Yes 6 PR2 62 747 No 0 1 Yes Yes Yes 7 Stair well 103 1864.3 No 0 1 Yes Yes Yes 8 Foyer 116 1438.4 No 0 1 Yes Yes Yes 9 Great Room 505 6063 No 4 1 Yes Yes Yes 10 Laundry 72 864 No 0 1 Yes Yes Yes 11 Master Suite 259 3108 No 0 1 1 Yes Yes Yes 12 Master Bath 150 1800 No 0 1 Yes Yes Yes 13 WIC1 88 1056 No 0 1 Yes Yes Yes 14 Lavi 18 216 No 0 1 Yes Yes Yes 15 Sitting 112 896 No 0 1 Yes Yes Yes 16 Game Room 430 3440 No 4 1 Yes Yes Yes 17 Upper Landing 140 1120 No 0 1 Yes Yes Yes 18 Loft 192 1536 No 0 1 Yes Yes Yes 19 Bath 2 78 624 No 0 1 Yes Yes Yes 20 Bedroom 2 226 1808 No 1 1 1 Yes Yes Yes 21 Media Room 376 3308.8 No 10 1 Yes Yes Yes 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 WIC2 27 216 No 0 1 No Yes Yes 23 Bedroom 3 197 1576 No 1 1 1 Yes Yes Yes 24 Bath3 74 592 No 0 1 Yes Yes Yes 25 CL03 16 128 No 0 1 Yes Yes Yes 26 Lin 6 48 No 0 1 No Yes Yes 27 AHU 14 112 No 0 1 No Yes Yes 28 Hall 88 704 No 0 1 No Yes Yes 29 Observation Room 360 3240 No 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Breezeway 92.5 ft 0 269 ft2 ---_ 1 0 0 2 Slab -On -Grade Edge Insulatio Wine Room 45 ft 0 174 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Dining 37 ft 0 291 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Kitchen 1 ft 0 190 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Library 23.6 ft 0 239 ft2 -_-- 1 0 0 6 Slab -On -Grade Edge Insulatio PR2 4 ft 0 62 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Stair well 22.5 ft 0 103 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio Foyer 10.5 ft 0 116 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Great Room 18.5 ft 0 505.3 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Laundry 11 ft 0 72 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Master Suite 17.5 ft 0 259 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Master Bath 16.5 ft 0 150 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulatio WIC1 13.5 ft 0 88 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulatio Lav1 5 ft 0 18 ft2 ---_ 1 0 0 15Floor Over Other Space Bath 2 ---- ____ 78 ft2 0 0 0 1 16Floor Over Other Space Media Room ---- ---- 376 ft2 0 0 0 1 17FIoor Over Other Space Bedroom 3 ---- ---_ 197 ftz 0 0 0 1 18FIoor Over Other Space Bath3 ____ ---- 74 ft2 0 0 0 1 19FIoor Over Other Space CL03 ____ _--- 16 ft2 0 0 0 1 20Floor Over Other Space Sitting ---- ---- 112 ft2 0 0 0 1 21Floor Over Other Space Loft ____ ---_ 192 ft2 0 0 0 1 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 9 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22FIoor Over Other Space Upper Landing ---- ____ 140 ft2 0 0 0 1 23FIoor Over Other Space AHU --_- --__ 14 ft2 0 0 0 1 24FIoor Over Other Space Bedroom 2 ---- ---- 226 ft2 0 0 0 1 25FIoor Over Other Space WIC2 _--_ ____ 27 ft2 0 0 0 1 26FIoor Over Other Space Observation Roo ---- ---- 360 ft2 0 0 0 1 27Floor Over Other Space Lin ____ _-__ 6 ft2 0 0 0 1 28Floor Over Other Space Game Room ___- ---_ 430 ft2 0 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Flat tile/slate 3010 ft2 674 ft2 Light 0.6 Yes 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2691 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Breezeway 30 269 ft2 0.1 Wood 2 Under Attic (Vented) Wine Room 30 63 ft2 0.1 Wood 3 Under Attic (Vented) Library 30 48 ft2 0.1 Wood 4 Under Attic (Vented) Stair well 30 52 ft2 0.1 Wood 5 Under Attic (Vented) Master Bath 30 150 ft2 0.1 Wood 6 Under Attic (Vented) WIC1 30 88 ft2 0.1 Wood 7 Under Attic (Vented) Lav1 30 18 ft2 0.1 Wood 8 Under Attic (Vented) Sitting 30 112 ft2 0.1 Wood 9 Under Attic (Vented) Game Room 30 230 ft2 0.1 Wood 10 Under Attic (Vented) Upper Landing 30 140 f12 0.1 Wood 11 Under Attic (Vented) Loft 30 139 ft2 0.1 Wood 12 Under Attic (Vented) Bath 2 30 78 ft2 0.1 Wood 13 Under Attic (Vented) Bedroom 2 30 226 ft2 0.1 Wood 14 Under Attic (Vented) Media Room 30 376 ft2 0.1 Wood 15 Under Attic (Vented) WIC2 30 27 ft2 0.1 Wood 16 Under Attic (Vented) Bedroom 3 30 197 ft2 0.1 Wood 17 Under Attic (Vented) Bath3 30 43 ft2 0.1 Wood 18 Under Attic (Vented) CL03 30 16 ft2 0.1 Wood 19 Under Attic (Vented) Lin 30 6 ft2 0.1 Wood 20 Under Attic (Vented) AHU 30 14 ft2 0.1 Wood 21 Under Attic (Vented) Hall 2 30 41 ft2 0.1 Wood 22 Under Attic (Vented) Observation Roo 30 360 ft2 0.1 Wood 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 9 WALLS Adjacent Tn Space Wall Type Cavity Width Height Sheathing Framing Solar w BeloIf 1 --Ornt N=>E Exterior Concrete Block - Int InsuBreezeway 5 30 6 12 0 366.0 ft2 12.39 ' 0 0.6 0 2 E=>S Exterior Concrete Block - Int InsuBreezeway 5 19 0 12 0 228.0 ft2 12.39 0 0.6 0 3 S=>W Exterior Concrete Block - Int InsuBreezeway 5 24 0 12 0 288.0 ft2 12.9 0 0.6 0 4 W=>N Exterior Concrete Block - Int InsuBreezeway 5 19 0 12 0 228.0 ft2 12.39 0 0.6 0 5 N=>E Exterior Concrete Block - Int InsMine Room 5 9 6 12 0 114.0 ft2 12.39 0 0.6 0 6 NE=>SE Exterior Concrete Block - Int InsMine Room 5 3 6 12 0 42.0 ft2 12.39 0 0.6 0 7 E=>S Exterior Concrete Block - Int InsMine Room 5 13 0 12- 0 156.0 ft2 12.39 0 0.6 0 8 SE=>SW Exterior Concrete Block - Int InsL))Vine Room 5 3 6 12 0 42.0 ft2 12.39 0 0.6 0 9 S=>W Exterior Concrete Block - Int InsLVVine Room 5 9 6 12 0 114.0 ft2 12.39 0 0.6 0 10 N=>E Exterior Concrete Block - Int Insul Dining 5 13 0 12 0 156.0 ft2 12.39 0 0.6 0 11 E=>S Exterior Concrete Block - Int Insul Dining 5 12 6 12 0 150.0 ft2 12.39 0 0.6 0 12 W=>N Exterior Concrete Block - Int Insul •Dining 5 11 6 12 0 138.0 ft2 12.39 0 0.8 0 13 E=>S Exterior Concrete Block - Int Insul Library 5 7 5 14 7 108.2 ft2 12.39 0 0.6 0 14 SE=>SW Exterior Concrete Block - Int Insul Library 5 4 8 14 7 68.1 ft2 12.39 0 0.6 0 15 S=>W Exterior Concrete Block - Int Insul Library 5 7 5 14 7 108.2 ft2 12.39 0 0.6 0 16 E=>S Exterior Concrete Block - Int Insul PR2 5 2 6 12 0 30.0 ft2 12.39 0 0.6 0 17 S=>W Exterior Concrete Block - Int Insul PR2 5 1 6 12 0 18.0 ft2 12.39 0 0.6 0 18 E=>S Exterior Concrete Block - Int Insul Stairwell 5 3 4 18 1 60.3 ft2 12.39 0 0.6 0 19 S=>W Exterior Frame - Wood Stair well 19 3 0 18 1 54.3 ft2 0 0.25 0.8 0 20 S=>W Exterior Concrete Block - Int Insul Stairwell 5 6 4 18 1 114.5 ft2 12.39 0 0.6 0 21 W=>N Exterior Frame - Wood Stair well 19 5 4 18 1 96.4 ft2 0 0.25 0.8 0 22 W=>N Exterior Concrete Block - Int Insul Stairwell 5 5 4 18 1 96.4 ft2 12.39 0 0.6 0 23 S=>W Exterior Concrete Block - Int Insul Foyer 5 10 6 12 5 130.4 ft2 12.39 0 0.6 0 24 N=>E Exterior Concrete Block - Int InsLffireat Room 5 18 6 12 0 222.0 ft2 12.39 0 0.6 0 25 S=>W Exterior Concrete Block - Int Insul Laundry 5 11 0 12 0 132.0 ft2 12.39 0 0.6 0 26 N=>E Exterior Concrete Block - Int Insffilaster Suite 5 14 0 12 0 168.0 ft2 12.39 0 0.6 0 27 E=>S Exterior Concrete Block - Int Insffilaster Suite 5 3 6 12 0 42.0 ft2 12.39 0 0.6 0 28 N=>E Exterior Concrete Block - Int InsLIVIaster Bath 5 11 6 12 0 138.0 ft2 12.39 0 0.6 0 29 W=>N Exterior Concrete Block - Int InsWaster Bath 5 5 0 12 0 60.0 ft2 12.39 0 0.6 0 30 N=>E Exterior Concrete Block - Int Insul WIC1 5 5 0 12 0 60.0 ft2 12.39 0 0.6 0 31 W=>N Exterior Concrete Block - Int Insul WIC1 5 8 6 12 0 102.0 ft2 12.39 0 0.6 0 32 W=>N Exterior Concrete Block - Int Insul Lavi 5 5 0 12 0 60.0 ft2 12.39 0 0.6 0 33 N=>E Exterior Frame - Wood Sitting 19 9 0 8 0 72.0 ft2 0 0.25 0.8 0 34 NE=>SE Exterior Frame - Wood Sitting 19 2 10 8 0 22.6 ft2 0 0.25 0.8 0 35 E=>S Exterior Frame - Wood Sitting 19 6 6 8 0 52.0 ft2 0 0.25 0.8 0 _36 SE=>SW Exterior Frame - Wood Sitting 19 2 10 8 0 22.6 ft2 0 0.25 0.8 0 37 S=>W Exterior Frame - Wood Sitting 19 9 0 8 0 72.0 ft2 0 0.25 0.8 0 38 N=>E Exterior Frame - Wood Game Room 19 19 6 8 0 156.0 ft2 0 0.25 0.8 0 39 E=>S Exterior Frame - Wood Game Room 19 14 6 8 0 116.0 ft2 0 0.25 0.8 0 40 W=>N Exterior Frame - Wood Game Room 19 8 0 8 0 64.0 ft2 0 0.25 0.8 0 41 E=>S Exterior Frame - Wood Upper Landin 19 7 6 8 0 60.0 ft2 0 0.25 0.8 0 42 S=>W Exterior Frame - Wood Upper Landin 19 5 0 8 0 40.0 ft2 0 0.25 0.8 0 43 E=>S Exterior Frame - Wood Loft 19 13 6 8 0 108.0 ft2 0 0.25 0.8 0 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 9 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space 44 SE=>SW Exterior Frame - Wood Loft 19 5 8 8 0 45.3 ft2 0 0.25 0.8 0 45 S=>W Exterior Frame - Wood Loft 19 10 6 8 0 84.0 ft2 0 0.25 0.8 0 46 W=>N Exterior Frame - Wood Loft 19 4 0 8 0 32.0 ft2 0 0.25 0.8 0 47 S=>W Exterior Frame - Wood Bath 2 19 , 6 6 8 0 52.0 ft2 0 0.25 0.8 0 48 W=>N Exterior Frame - Wood Bath 2 19 12 0 8 0 96.0 ftz 0 0.25 0.8 0 49 N=>E Exterior Frame - Wood Bedroom 2 19 13 0 8 0 104.0 ft2 0 0.25 0.8 0 50 W=>N Exterior Frame - Wood Bedroom 2 19 14 0 8 0 112.0 ft2 0 0.25 0.8 0 51 S=>W Exterior Frame - Wood Media Room 19 21 6 8 10 189.2 ft2 0 0.25 0.8 0 52 W=>N Exterior Frame - Wood Media Room 19 9 0 8 10 79.2 ft2 0 0.25 0.8 0 53 N=>E Exterior Frame - Wood Bedroom 3 19 14 6 8 0 116.0 ft2 0 0.25 0.8 0 54 N=>E Exterior Frame - Wood Bath3 19 2 6 8 0 20.0 ft2 0 0.25 0.8 0 55 N=>E Exterior Frame - Wood CL03 19 2 6 8 0 20.0 ft2 0 0.25 0.8 0 56 N=>E Exterior Frame - Wood Observation 19 20 0 9 0 180.0 ft2 0 0.25 0.8 0 57 E=>S Exterior Frame - Wood Observation 19 18 0 9 0 162.0 ft2 0 0.25 0.8 0 58 S=>W Exterior Frame - Wood Observation 19 20 0 9 .0 180.0 ft2 0 0.25 0.8 0 59 W=>N Exterior Frame - Wood Observation 19 18 0 9 0 162.0 ft2 0 0.25 0.8 0 60 S=>W Garage Frame - Wood WIC1 19 45 6 12 0 546.0 ft2 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>W Wood Foyer None .39 6 9. 54 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>E 1 Vinyl Low-E Double Yes 0.43 0.2 67.6 ft2 1 ft 6 in 2 ft 0 in None None 2 S=>W 3 Vinyl Low-E Double Yes 0.43 0.2 33.8 ft2 1 ft 6 in 2 ft 0 in None None 3 S=>W 3 Vinyl Low-E Double Yes 0.43 0.2 48.0 ft2 1 ft 6 in 2 ft 0 in None None 4 W=>N 4 Vinyl Low-E Double Yes 0.43 0.2 33.8 f12 1 ft 6 in 2 ft 0 in None None 5 N=>E 5 Vinyl Low-E Double Yes 0.43 0.2 32.0 ft2 1 ft 6 in 2 ft 0 in None None 6 NE=>SE 6 Vinyl Low-E Double Yes 0.43 0.2 15.1 ft2 1 ft 6 in 2 ft 0 in None None 7 E=>S 7 Vinyl Low-E Double Yes 0.43 0.2 32.0 ft2 1 ft 6 in 2 ft 0 in None None 8 SE=>SW 8 Vinyl Low-E Double Yes 0.43 0.2 15.1 ft2 1 ft 6 in 2 ft 0 in None None 9 S=>W 9 Vinyl Low-E Double Yes 0.43 0.2 15.6 ft2 1 ft 6 in 2 ft 0 in None None 10 N=>E 10 Vinyl Low-E Double Yes 0.43 0.2 77.8 ft2 1 ft 6 in 2 ft 0 in None None 11 E=>S 11 Vinyl Low-E Double Yes 0.43 0.2 32.9 ft2 1 ft 6 in 2 ft 0 in None None 12 W=>N 12 Vinyl Low-E Double Yes 0.43 0.2 16.0 ft2 8 ft 0 in 1 ft 0 in None None 13 W=>N 12 Vinyl Low-E Double Yes 0.43 0.2 64.0 ft2 8 ft 0 in 2 ft 0 in None None 14 E=>S 13 Vinyl Low-E Double Yes 0.43 0.2 16.0 ft2 1 ft 6 in 2 ft 0 in None None 15 SE=>SW 14 Vinyl Low-E Double Yes 0.43 0.2 15.1 ft2 1 ft 6 in 2 ft 0 in None None 16 S=>W 15 Vinyl Low-E Double Yes 0.43 0.2 16.0 ft2 1 ft 6 in 2 ft 0 in None None 17 S=>W 19 Vinyl Low-E Double Yes 0.43 0.2 27.3 ft2 1 ft 6 in 1 ft 0 in None None 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 9 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt fD Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening . 18 N=>E 24 Vinyl Low-E Double Yes 0.43 0.2 32.0 ft2 8 ft 0 in 1 ft 0 in None None 19 N=>E 24 Vinyl Low-E Double Yes 0.43 0.2 128.0 ft2 12 ft 0 in 2 ft 0 in None None 20 S=>W 25 Vinyl Low-E Double Yes 0.43 0.2 24.0 ft2 1 ft 6 in 2 ft 0 in None None 21 N=>E 26 Vinyl Low-E Double Yes 0.43 0.2 77.8 ft2 1 ft 6 in 2 ft 0 in None None 22 E=>S 27 Vinyl Low-E Double Yes 0.43 0.2 20.0 ft2 8 ft 0 in 2 ft 0 in None None 23 E=>S 27 Vinyl Low-E Double Yes 0.43 0.2 5.0 ft2 8 ft 0 in 1 ft 0 in None None 24 N=>E 28 Vinyl Low-E Double Yes 0.43 0.2 45.9 ft2 1 ft 6 in 2 ft 0 in None None 25 W=>N 32 Vinyl Low-E Double Yes 0.43 0.2 9.0 ft2 1 ft 6 in 2 ft 0 in None None 26 N=>E 33 Vinyl Low-E Double Yes 0.43 0.2 23.1 ft2 1 ft 6 in 1 ft 0 in None None 27 NE=>SE 34 Vinyl Low-E Double Yes 0.43 0.2 11.1 ft2 1 ft 6 in 1 ft 0 in None None 28 E=>S 35 Vinyl Low-E Double Yes 0.43 0.2 23.1 ft2 1 ft 6 in 1 ft 0 in None None 29 SE=>SW36 Vinyl Low-E Double Yes 0.43 0.2 11.1 ft2 1 ft 6 in 1 It 0 in None None 30 S=>W 37 Vinyl Low-E Double Yes 0.43 0.2 23.1 ft2 1 ft 6 in 1 ft 0 in None None 31 N=>E 38 Vinyl Low-E Double Yes 0.43 0.2 66.2 ft2 1 ft 6 in 1 ft 0 in None None 32 E=>S 39 Vinyl Low-E Double Yes 0.43 0.2 32.9 ft2 1 ft 6 in 1 ft 0 in None None 33 E=>S 43 Vinyl Low-E Double Yes 0.43 0.2 11.8 ft2 1 ft 6 in 1 ft 0 in None None 34 SE=>SW44 Vinyl Low-E Double Yes 0.43 0.2 11.5 ft2 1 ft 6 in 1 ft 0 in None None 35 S=>W 45 Vinyl Low-E Double Yes 0.43 0.2 11.5 ft2 1 ft 6 in 1 ft 0 in None None 36 S=>W 47 Vinyl Low-E Double Yes 0.43 0.2 6.9 ft2 1 ft 6 in 1 ft 0 in None None 37 N=>E 49 Vinyl Low-E Double Yes 0.43 0.2 32.9 ft2 1 ft 6 in 1 ft 0 in None None 38 S=>W 51 Vinyl Low-E Double Yes 0.43 0.2 12.0 ft2 1 ft 6 in 1 ft 0 in None None 39 N=>E 53 Vinyl Low-E Double Yes 0.43 0.2 24.0 ft2 1 ft 6 in 1 ft 0 in None None 40 N=>E 54 Vinyl Low-E Double Yes 0.43 0.2 5.3 ft2 1 ft 6 in 1 ft 0 in None None 41 N=>E 56 Vinyl Low-E Double Yes 0.43 0.2 52.8 ft2 1 ft 6 in 1 ft 0 in None None 42' E=>S 57 Vinyl Low-E Double Yes 0.43 0.2 39.6 ft2 1 ft 6 in 1 ft 0 in None None 43 S=>W 58 Vinyl Low-E Double Yes 0.43 0.2 39.6 ft2 1 ft 6 in 1 ft 0 in None None 44 W=>N 59 Vinyl Low-E Double Yes 0.43 0.2 52.8 ft2 1 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 506 ft2 506 ft2 45 ft 12 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 6371.3 349.78 657.81 .5214 7.514 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 9 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 21.1 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP: 1 40.55 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16.3 42 kBtu/hr cfm 0.81 1 sys#1 2 Central Unit Split SEER: 16.3 42 kBtu/hr cfm 0.81 2 sys#2 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 1005 ft2 Attic 1005 ft2 Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 933 ft2 Attic 933 ftz Default Leakage AHU (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]Jan ] Feb [ Mar Apr [ j Ma Jun X Jul Au Se f Oct Nov Dec Heatin[X] Jan f X] Feb [X� Mar f Apr [ ]May Jun Jul rj Au �Xj SeP rj Oct Nov X Dec Ventin [[ ] Jan [ ] Feb [X Mar [X] A r [ ] Ma Jun [ Jul Aug Se [X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66' 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/1/2014 8:12 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 8 of 9 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Hutchinson Island, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARYOF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/1/2014 8:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 9 of 9