HomeMy WebLinkAboutEvaluation ReportP L4 IMES Evaluation Report ESR-2074* Reissued December 1, 2012 This report is subject to renewal February 1, 2015. wwwacc-es.ora 1. (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com info(&smartvent.com EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENt- MODEL #1540520; FLOODVENTTm STACKING MODEL #1540521; SMARTVENTTm MODEL #1540510; SMARTVENTTm STACKING MODEL #1540-611; WOOD WALL FLOOD MODEL #1540570; WOOD WALL FLOOD OVERHEAD DOOR MODEL #1540574; FLOODVENT- OVERHEAD DOOR MODEL #1540-624; SMARTVENTTm OVERHEAD DOOR MODEL #1540514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2009 and 2006 International Building Code® (IBC) ■ 2009 and 2006 International Residential Code® (I RC) Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are automatic foundation flood vents (AFFVs) employed to equalize hydrostatic pressure on nonfire-resistance-rated foundation walls, rolling -type overhead doors. and building walls subject to rising or falling flood waters. The Smart Vent® units are intended for use where flood hazard areas have been established in accordance with IBC Section 1612.3 or IRC Section R3222.1. Certain models also allow natural ventilation in accordance with Section 1203 of the IBC or Section 408.1 of the IRC. 3.0 DESCRIPTION 3.1 General: When subjected to pressure from rising water, the Smart Vent® AFFVs disengage, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The AFFV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the plate to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. The SmartVENTTA° Stacking Model #1540-511 and FloodVENTTm Stacking Model #1540-521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The AFFVs comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent AFFVs must be installed in accordance with Section 4.0. 3.3 Model Sizes: The FloodVENTTm Model #1540-520, SmartVENTTm Model #1540-510, FloodVENT"m Overhead Door Model #1540-524, and SmartVENTTm 'Overhead Door Model #1540-514 units measure 153/4 inches wide by 73/4 inches high (400 by 196.9 mm). The Wood Wall Flood Model #1540-570.and Wood Wall Flood Overhead Door Model #1540-574 units measure 14 inches wide by 83/4 inches high (355.6 by 222.25 mm). The SmartVENTTm Stacking Model #1540-511 and FloodVENTTm Stacking Model #1540-521 units measure 16 inches wide by 16 inches high (406.4 by 406.4 mm). 3.4 Ventilation: The SmartVENT' Model #1540-510 and SmarIVENT® Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENTTm Stacking Model #1540-511 consists of two .Model #1540-510 units in one assembly, and provides 102 square inches• (65 806 mm2) of net free area to supply natural ventilation. Other AFFVs recognized in this report do not offer natural ventilation. 4.0 INSTALLATION SmartVENT® and FloodVENTTM are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. The mounting straps allow mounting in wood, masonry and *Revised July 2013 1CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not spec fcally addressed nor are they to be construed MM as an endorsement of the subject of the report or a recommendation far its use. There is no warranty by 1CC Evaluation Service, LLC, express or implied as to any finding or other matter in this report, or as to any product covered by the report. "aR 'T Copyright © 2013 Page 1 of 2 ESR-2074 I Most Widely Acceptrrr `sted l Page 2 of 2 concrete walls -up to 12 inches (305 mm) thick. In order to 5.1 The Smart Vent® AFFVs must be installed in comply with the engineered opening design principle noted accordance with this report, the -applicable code and in Section 2.6.2.2 of ASCE/SEI 24, the Smart Vent® AFFVs the manufacturer's installation instructions. In the must be installed as follows: event of a conflict the instructions in this report ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one AFFV for every 200 square feet (18.6 m) of enclosed area, except that the SmartVENTTm Stacking Model #1540-511 and FloodVENTTm Stacking Model #1540-521 must be installed with a minimum of one AFFV for every 400 square feet (37.2 mZ) of enclosed area. ■ Below the base flood elevation. ■ With the bottom of the AFFV located a maximum of 12 inches (305.4 mm) above grade. 6.0 CONDITIONS OF USE The Smart Vent® AFFVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: govern. 5.2 The Smart Vent® AFFVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED, Data in accordance with the ICC-ES Acceptance Criteria for Automatic Foundation Flood Vents (AC364), dated October 2007. 7.0 IDENTIFICATION The Smart VENT® models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR-2074). IMES Evaluation Report ESR-2074 FBC Supplement Issued July 1, 2013 This report is subject to renewal February 1, 2015. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com i nfo(a)smartvent.com EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENTM MODEL #1540-520; FLOODVENTM STACKING MODEL #1640521; SMARTVENTTM' MODEL #1540-610; SMARTVENTT"' STACKING MODEL #1640-611; WOOD WALL FLOOD MODEL #1540-570; WOOD WALL FLOOD OVERHEAD DOOR MODEL #1540-574; FLOODVENTTM' OVERHEAD DOOR MODEL" #1640-624; SMARTVENTTM' OVERHEAD DOOR MODEL #1540-514 1.0 ' REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vene Automatic Foundation Flood Vents, recognized in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2010 Florida Building Code —Building (FBC) ■ 2010 Florida Building Code —Residential (FRC) 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2,0 through 7.0 of the master evaluation report ESR-2074, comply with the FBC and the FRC, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report. Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the FBC and the FRC for structures not subject to FBC Section 2326.3.1 or FRC Section 4409.13.3.1, as applicable. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued December 1, 2012, revised July 2013. !CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed RM as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by /CC Evaluation Service, LLC, express or implied as p: to anyjinding or other matter in this report, or as to any product covered by the report. loco-"` Copyright© 2013 Page 1 of 1