31 • FL # FL5822-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Smart Vent Products, Inc.
Address/Phone/Email 430 Andbro Dr Unit 1
Pitman, N3 08071
(877)441-8368
info@smartvent.com
Authorized Signature Michael Graham
info@smartvent.com
Technical Representative Michael 3. Graham
Address/Phone/Email 20 Warrick Ave.
Glassboro, N3, N3 08028
(888) 628-4115
mike@smartvent.com
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Products Introduced as a Result of New Technology
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
© Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Hermes F. Norero P.E.
the Evaluation Report
Florida License PE-73778
Quality Assurance Entity Architectural Testing, Inc.
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Locke Bowden
61 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL5822 R3 COI Smart Vent COI SS 2015-02-23.odf
1612.5(1)(1.2)
1709.2'
https://floridabuilding.orglprlpr_app dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLmlm... 8/31/2016
Florida Building Code Online
rage L or .s
Product Approval Method Method 2 Option B
Date Submitted
02/26/2015
Date Validated
02/27/2015
Date Pending FBC Approval
03/03/2015
Date Approved
04/15/2015
Summary of Products
FL #
Model, Number or Name
Description
5B22.1
Model #1540-510
SmartVent.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
PTID 5822 I Installation Instructions.ndf
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Other: One vent may be used for up to 200 sq. ft. of
interior space (minimum 2).
Evaluation Reports
FL5822 R3 AE PER3229 SS 2015-02-23.pdf
FL5822 R3 AE SmartVent - Impact Requirements Letter_
SS 2015-02-26.0
Created by Independent Third Party: Yes
5822.2
Model #1540-514
SmartVent Overhead Door Model
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions
FL5822 R3 II Installation Instructions.0
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Other: One vent may be used for up to 200 sq. ft. of
Interior space (minimum 2).
Evaluation Reports
FL5822 R3 AE PER3229 SS 2015-02-23.odf
FL5822 R3 AE SmartVent - Impact Requirements Letter
SS 2015-02-26.0f
Created by Independent Third Party: Yes
5822.3
j Model #1540-520
FloodVent
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R3 II Installation Instructions.ndf
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of
FL5822 R3 AE PER3229 SS 2015-02-23.odf
interior space (minimum 2).
FL5822 R3 AE SmartVent - Imoact Requirements Letter
SS 2015-02-26.odf
Created by Independent Third Party: Yes
5822.4
Model #1540-524
FloodVent Overhead Door Model
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5822 R3 II installation Instructions.pdf
Approved for use outside HVHZ: Yes
Verified By: Hennes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +100/-100
Evaluation Reports
Other: One vent may be used for up to 200 sq. ft. of
FL5822 R3 AE PER3229 SS 2015-02-23.odf
Interior space (minimum 2).
FL5822 R3 AE SmartVent - Imoact Requirements Letter
SS 2015-02-26.r)dF
Created by Independent Third Party: Yes
5822.5
Model #1540-570
Wood Wall FloodVent
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +100/-100
Other: One vent maybe used for up to 200 sq. ft. of
interior space (minimum 2).
Installation Instructions
FL5822 R3 II Installation Instructions.odf
Verified By: Hennes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R3 AE PER3229 SS 2015-02-23.pdf
FL5822 R3 AE SmartVent - Impact Requirements Letter
SS 2015-02-26.0
Created by independent Third Party: Yes
5822.6
Model #1540-574
Wood Wall FloodVent Overhead Door Model
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +300/-100
Other: One vent may be used for up to 200 sq. ft. of
Interior space (minimum 2).
Installation Instructions
F1-5822 R3 II Installation Instructions. odf
Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL5822 R3 AE PER3229 SS 2015-02-23.pdf
FL5822 R3 AE SmartVent - Imoact Requirements Letter
SS 2015-02-26.odf
Created by Independent Third Party: Yes
https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLmlm... 8/31 /2016
FRAME
FIGURE 2
SIDE VIEW
DETAIL DIAGRAM
MODEL 1540-510
DUAL FUNCTION FLOOD AND VENTILATION VENT
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2017.02.28 18:51:11-05'00'
SMART VENT Foundation Flood Vents
430 AndBro Dr., Unit 1
Pitman NJ 08071
SMART VENTe
877-441-8368
DUAL FUNCTION FLOOD
AND VENTILATION VENT
WWW.SMARWENr.COM
MODEL 1540-510
AS1
A
I IHo. 1540-510
RA
DATE B-21-16 SHEET 1 OF 2
A16�4��
Smart VENT
877— 441 — 8368
www.smartvent.com
INSTALLATION INSTRUCTIONS
& DETAILS
MODEL 1540-510
DUAL FUNCTION FLOOD AND VENTILATION VENT
REV. 6-21-16
• �- O J
� � r
CC
_ 7 r
4
iN 0. P-*-
FjP
J96 pp 6L `
�I CF7t1l4F.QyyWaL►T 78
1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT)
2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN
12" ABOVE THE FINISHED GRADE.
3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2)
4. INSERT INSTALLATION CUPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME.
5. THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME.
COMPRESS THE BOTTOM TWO CUPS AND BEGIN SLIPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CUPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS.
6. WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS .AND PUSH THE VENT FRAME INTO THE OPENING
COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL
7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK.
8. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND
ROTATE UNTIL IT IS LATCHED.
9. INSERT THE TOP STRAPS INTO THE TOP TWO STRAP SLOTS ABOUT TWO CLICKS.
10. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING.
DETAILED SPECIFICATIONS:
MATERIAL- STAINLESS STEEL
OPERATION FLOOD: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION
VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED
OPERATION AIR: AUTOMATIC LOUVERS FULLY OPEN AT 75 DEG. FULLY CLOSED AT 35 DEG. NO POWER REQUIRED
INSTALLATION:
SECURED W/ 4 STAINLESS STEEL INSTALLATION CUPS INCLUDED AND AN ADHESIVE
HYDROSTATIC RELIEF: 200 SQ. FT PER VENT
VENTILATION: 51 SQ. IN. PER VENT NOTE: VAPOR BARRIER ALLOWS FOR REDUCED VENTILATION
REQUIREMENTS FLOOD: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS
COLORS: STAINLESS (STANDARD)
EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE)
MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY:
FEMA, NFIP, ICC, & ASCE
SUPPORTIVE DOCUMENTS, TB 1-08. 44CFR 60.3(C)(5), ASCE 24-14
ICC EVALUATION # ESR-2074
SHEET 2 OF 2