HomeMy WebLinkAboutWALL COMPONENTS & CLADDING SERVICE WIND LOADSENGINEER: JCH 1 OF 1
AREA Interior End
(ft2) Zone (psf) Zone (psf)
10 46 -50 46 -62
20 44 -48 44 -57
30 43 -47 43 -55
40 42 -46 42 -53
50 41 -45 41 -52
75 40 -44 40 -50
100 39 -43 39 -48
200 37 -41 37 -44
500 34 -38 34 -38
OWNER: MAGGARD RESIDENCE
ADDRESS:
CODE: A.S.C.E. 7-16
Velocity = 160 m.p.h.
Risk Category = II
Distance from Coastline (ft): YES
Distance for EXP. D (ft): 500
Exposure = D
Mean Roof Height = 25 Feet
Kzt = 1.0
Kd = 0.85
G = 0.85
GCpi = +/- 0.18
qh = 39.0 p.s.f.
End zone = 4 Feet
Jason Hanchuk, P.E. #56787
1770 Pierside Circle
Wellington, FL 33414
(561) 818-1935
1/27/2022
Jason Hanchuk, State of Florida Professional
Engineer, License No. 56787. This item has
been digitally signed and sealed by Jason
Hanchuk, PE on the date noted herein shown
on the digital seal. Printed copies of this
document are not considered signed and sealed
and the signature must be verified on any
electronic copies.
2703 N. Highway A1A, #E
Fort Pierce, FL 34949
WALL COMPONENTS & CLADDING SERVICE
WIND LOADS
1/27/2022 W.xlsx