Loading...
HomeMy WebLinkAboutWALL COMPONENTS & CLADDING SERVICE WIND LOADSENGINEER: JCH 1 OF 1 AREA Interior End (ft2) Zone (psf) Zone (psf) 10 46 -50 46 -62 20 44 -48 44 -57 30 43 -47 43 -55 40 42 -46 42 -53 50 41 -45 41 -52 75 40 -44 40 -50 100 39 -43 39 -48 200 37 -41 37 -44 500 34 -38 34 -38 OWNER: MAGGARD RESIDENCE ADDRESS: CODE: A.S.C.E. 7-16 Velocity = 160 m.p.h. Risk Category = II Distance from Coastline (ft): YES Distance for EXP. D (ft): 500 Exposure = D Mean Roof Height = 25 Feet Kzt = 1.0 Kd = 0.85 G = 0.85 GCpi = +/- 0.18 qh = 39.0 p.s.f. End zone = 4 Feet Jason Hanchuk, P.E. #56787 1770 Pierside Circle Wellington, FL 33414 (561) 818-1935 1/27/2022 Jason Hanchuk, State of Florida Professional Engineer, License No. 56787. This item has been digitally signed and sealed by Jason Hanchuk, PE on the date noted herein shown on the digital seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2703 N. Highway A1A, #E Fort Pierce, FL 34949 WALL COMPONENTS & CLADDING SERVICE WIND LOADS 1/27/2022 W.xlsx