Loading...
HomeMy WebLinkAboutAPPROVED, Dynamic Metals Standing Seam product approvals(1)Florida Building Code Online 8/3/21, 7:34 PM BCIS Home I Log In I User Registration 1 Hot Topics I Submit Surcharge I stats & Facts Publications I Contact Us BCIS Site Map , Links Search 1 FI ilda Product Approval r USER: Public User 8 Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL27499-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Scott Wolters the Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence FL27499 R4_C0I_Dyn COI.pdf Referenced Standard and Year (of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 1 of 5 Florida Building Code Online 8/3/21, 7:34 PM Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 04/18/2021 Date Validated 04/30/2021 Date Pending FBC Approval 05/03/2021 Date Approved 06/08/2021 Go to Page ID 0 Pagel/ 2 0 40 FL # Model, Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499...._94_II_4991 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27429_R4_AE_4991 Eval.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip, .032" Aluminum roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_94_II_4992 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva] report for Limits of Use. FL2749994_AE_4992 Eval.pdf Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_.4993 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4_AE_4993 Eval. ( f Created by Independent Third Party: Yes 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL2749 _94._II_4994 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_R4 AE_4994 Eval.pdf Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_.94_II_4995 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https://fioridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 2 of 5 Florida Building Code Online 8/3/21, 7:34 PM Other: Please see Eval Report for Limits of Use. FL27499R4_AE_4995 Eval.pdf Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499_R4_II.._4996 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499_R4_AE__4996 Eval.pddf Limits of Use. Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 _R4__II 4997 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499_R4_ AE.._4997 Eval.pdf Limits of Use. Created by Independent Third Party: Yes 27499.8 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 20" wide, with 1 1/2" standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_4998 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. F 274 _R4_AE_4998 Eval.pd Created by Independent Third Party: Yes 27499.9 DM Class 1500 1 1/2" Mechanical 16 oz. Copper roof panel, 16" wide, with 1 1/2" standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499R4-_II 4999 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_R4_AE_4999 Eval.pdf Created by Independent Third Party: Yes 26 Ga. galvalume coated steel roof panel, 16" wide, with 1 27499.10 DM Class 1500 1 1/2" Mechanical Seam 1/2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_49910 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4_AE_49910 Eval.pdf Created by Independent Third Party: Yes 27499.11 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 16" wide, with 1 1/2" standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL274 R4_II__.49911 Dwg_ c—ff Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_94_AE_49911 Eval.pdf Created by Independent Third Party: Yes 27499.12 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 16" wide, with 1 Seam 1/2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4_II_49912 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 3 of 5 Florida Building Code Online 8/3/21, 7:34 PM Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_R4_AE_49912 Eval.pdf Created by Independent Third Party: Yes 27499.13 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 20" wide, with 1 Seam, 1/2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499R4..II 49913 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL274 9 94_AE_49913 Eval.pdf Created by Independent Third Party: Yes 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1 27499.14 DM Class 1750 1 3/4" Snaplock 3/4" Snaplock seams, attached to metal deck. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_49914 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499__.R4_AE_49914 Eval.pclf Created by Independent Third Party: Yes 27499.15 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4__II_49915 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_R4_AE_49915 Eval.pdf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4" Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL274 .._R4II_.._49916 Dwg_�f Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499,_94_..AE_49916 Eval.pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499._R4_II_49917 dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL2749 _R4_AE_49917 Eval.pd Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_49918 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499_R4_8E_49918 Eval.pdf Created by Independent Third Party: Yes 27499.19 DM Class 20 10 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%,3d%3d Page 4 of 5 Florida Building Code Online 8/3/21, 7:34 PM Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.20 I DM Class 500 5V Crimp FL27499_R4_II_49919 Dwg_pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL274 9_R4.....AE_49919 Eval.pdf Created by Independent Third Party: Yes 26 Ga. galvalume coated steel roof panel, 24" wide, with 5V crimp. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499_R4_II_49920 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499-_R4_AE_49920 Eval.pdf Created by Independent Third Party: Yes Go to Pagedft MW Back Next 00 Page l/200 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32392 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. L4R ri ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® E- Credit Card Safe https://floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d Page 5 of 5 --3-1Va 0 A38 SOJ G3nSSl Sl I ......S90Z-L6Z (ZLI) :Hd uu-,. ICOM%;4o'sN=I - o L66VE11 'iHvnis 30 I I 99VZ-LVZ(ZLL);XVJ jawjwa.xwDuXp-mmm DVURVDINIA003STOU S]V13N DINVNAC c d) U) o.G `0 m> w c oa�LL jl o %�I UJ \ 17 LU Z U- 0 R Z UJ m o i C/3 < Cl) cm WOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 15211 97th Road N West Palm Beach, FL 33412 Ph/Fx: (561) 225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16" WIDE ROOF PANEL (FLPA# 27499.1) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100, TAS 125, and ASTM E2140 by Intertek B&C with results shown in test reports G3443.40-450- 44, G3443.14-450-44, and M1607.01-450-44. It has also been tested per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "NSS16-HZ dated 8/16/19, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental Calculations to support NSS16-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4), Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener Spacing across panel: 16" (at Nailstrip) (Panels overlap with male/female snap fit) Min. Slope: HVHZ: V/12" Non-HVHZ: '/2 /12" 5PECIALIZING IN IMpAC( pE515TANf Cup"AINWALI.5, 5TOpEfpOW5, & WINDUW5 Option #1 Installation Option #2 Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6" Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocell 2300 or 2320 at Nailstrip side of seam at roof slopes <3"112" only) Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: '/s' (15132" min) 4-ply CDX Plywood or 3/4" solid wood planks (S.G. _ .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank nails spaced 6" on center. Note: The %" wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Arch itectlEngineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. Sp�CIFLiZING IN IMpAC1" p�5;51" \N1" CUprAINWAL�,S, STOIC FONTS, & W!Nt7OW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL #27499.1, DM Class 1000". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re -Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, 0%� ; Vv: No 62354 e Scott Wolteis * ' FL PE#6235411 STATE OF •4�j APR 15 20Z1 �'•• 5191�CIALIZING IN IMC'AU p�5ffAW CUrUAINWA,.5, 5t0I?VP0Nf5, & WINPO W5 3, VA3e Mai d3nSSI S1NISd ',�:� p'••� y ••'••. �'�4� MI-M (tog) g gt g - wWriens 1st : �2: OIUG 4 j JISF% .�� ,m v NOYA trnd ISM 3'3NVH9 3MMN trl d0 31V1S N Cw�M., jau-lwwa!womtp@o q{u! :lIM3 59vZ-LVZ (ZLU :Hd 994Z-1h2 (ZLL):XVJ 1660E li'INVnls jau-lnlaw�lwnuRp'n>n�.>. 3�VMa31 b"JINIWOO 35 T02E AO. I •, V .. MX29 13d li SIVEN DINVNAG _ SU3l'10M 11075 70M 'iyO �p ( I i Y C m m O V 0 1 NOf fl J C4 p a Yru2 � o o x m m m cn o M C N ( U U o � N N I I W = - J CD W r' Z tJ O Q 0 a Z W ri r = a O J O J co c d Ci tv