APPROVED DUCT AND CALCS
Project Summary Da e: wrightsoftg AHU 1 r QUICK CALCS, INC. 317 ST, LUC€E LANE, FT. PIERCE, FL 34946 PMne: 772-466-6799 Email: QUICKCALCSQAOLCOM For: SNOWE RESIDENCE Notes: Desim Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F 'F Outside db 90 75 °F °F Inside db 70 Inside db Design TD 28 °F Design TD 15 M °F Daily range Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 18034 Btuh Structure 19126 Btuh Ducts Central vent (0 cf) 4794 Btuh 0 Btuh Ducts Central vent (0 cim) 6146 0 Btuh Btuh Humidification 0 Btuh none Blower 0 Btuh Piping 0 Btuh Equipment load 22828 Btuh Use manufacturer's data n Ratelswin multi r Equipmen� sensible load 0.95 24009 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Fireplaces Average 0 Structure 2363 Btuh Ducts 1984 Btuh Central vent (0 cfrn) 0 Btuh Area(ft2) Heating Cooling 1333 1333 (none) Equipment 4347 Btuh Volume (f�) Airchangeslhour 10660 10660 0.29 0.16 Equipment Total Load (Sew 28356 Btuh Equiv. AVF (cfm) 52 28 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03700GOB0 AHRI ref Coil FX4DNF037L AHRI ref 202024448 Efficiency 100 EFF Efficiency 13.5 EER,16 SEER Heating input Heating output 6.5 kW 22167 Btuh Sensible cooling Latentcooling 24640 10560 Btuh Btuh Temperature rise Actual airflow 50 °F 403 cfrn Total cooling Actual airflow 35200 1173 Btuh cfm Airflowfactor 0,018 cfmlBtuh Airflowfactor 0.046 0.50 cfmlBtuh in H2O Static pressure 0.50 in H2O Static pressure Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrsightsnirt® 2022-Fete-0312:14A5 �M • • �- .1•11•1— -m Rlght-SUte®Uriversa€ 2021 21.0M R5U08101 Page t � I(aUICKV)oamertslWdUhLsoRHVACISNOWERES-rtp Calc=MJ8 Front Door faces: E Project Summary Date: P� wrightsoft° AHU 2 gr QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 PInw 772-466-6799 EmalI:OUICKCALC9�OL.COM For: SNOWE RESIDENCE Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25328 Btuh Structure 19190 Btuh Ducts 6042 Btuh Ducts 7448 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31370 Btuh Use manufacturer's data n Rate/swingq multipplier 0.95 Infiltration Equipmentsensibleload 25306 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1659 Btuh Ducts 2407 Btuh Central vent (0 dm) 0 Btuh Heatingg Coolingg (none) Area (ft) 2046 2046 Equipment latent load 4066 Btuh Volume (fta) 16364 16364 Archanges/hour 0.27 0.15 Equipment Total Load (Sen+Lat) 29372 Btuh Equiv AVF (cfm) 74 40 Req. total capacity at 0,70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03700GOBO AHRI ref Coil FX4DNF037L AHRI ref 202024448 Efficiency 100 EFF Efficiency 13.5 EER,16 SEER Heating Input 9.3 kW Sensible cooling 24640 Btuh Heating output 31767 Btuh Latent000ling 10560 Btuh Temperature rise 25 OF Total cooling 35200 Btuh Actual airflow 1173 dim Actual airflow 1173 cfin Airflowfactor 0.037 cfm/Btuh Airflowfactor 0.044 dmBtuh Static pressure 0.50 in H2O Staticpressure 0.50 in H2O Space thermostat Load sensible heat ratio 0,87 Calculations approved byACCAto meetall requirements of Manual J Sth Ed wrightsoft' 2022-Feb-0312:t4:45 Wglti-SU(e®Unvarsa1202121.0.06 RSW8101 Paget ...\QUICK�Doame�As\WngMsofl HVACISNOWE RES..np Caic=MJB Fronl Ooor faces:E El3r Sheet 1 Job #: I QUICK CALCS, INC. � Scale:l : 135 Performed for: SNOWE RESIDENCE 317 ST. LUCIE LANE FT. PIERCE, FL 34946 Phone: 772-46Fr6799 Q UICKCALCS@AOL.COM ; RightSuite® Universa12021 21.0.08 RSU08101 2022-Feb-03 12:15:07 ghtsoft I AC\SNOWE RES..tup �- wrightsoft® Duct System Summary Job AHU 1 By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 PWp :772-466-6799 EmaII:OUICKCALCS@AOLCOM For: SNOWE RESIDENCE External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) .Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.355 in/10011 403 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0,250 in H2O 0.355 in/100ft 1173 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) HxW (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 499 22 23 0,480 4.0 Ox0 MFx 9.2 95.0 BATH c 1739 33 81 0.456 5.0 Ox0 MFx 14.8 95.0 BEDROOMS c 1843 14 86 0.483 8.0 Ox0 MFx 8.5 95.0 DEN c 2439 32 113 0.475 TO Ox0 MFx 10.2 95.0 FORMAL LIVING-B c 5631 86 261 0.355 8.0 Ox0 VIFx 25.8 115.0 stl FORMAL LNING-C c 5631 86 261 0,373 8.0 Ox0 MFx 19.1 115.0 stl FORMAL LMNG-D c 5631 86 261 0.461 8.0 Ox0 MFx 13A 95.0 HALLWAY c 1635 35 76 0.473 5.0 Ox0 MFx 10.8 95.0 WIG c 223 10 10 0A71 6.0 Ox0 MFx 11.0 95.0 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Ueloc (fpm) Diam (in) HxW (in) Duct Material Trunk st1 PeakAVF 171 523 0,355 666 12.0 0 x 0 VinlAx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Ueloc (ipm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 403 1173 0 0 0 0 Ox 0 UIFx Badmalk camas name nee maa�anyo�ernddea _ � WI'1911Y50fY` 2022-Feh-0312:14:45 ..�.�r=� .•w.� o RI9IR-Sule®Uri�rsa1202121.0.06 RSU08101 Pagei /1�iCIA ...\QUICK�DoameMs\WnOlAsofl HVACISNOWE RES..nQ CaIc=MJB Frort Doorfaces: E + wrightsoW Duct System Summary o AHU 2 By. QUICK CALCS, INC. 317 ST. LUCIE LANE, Fi PIERCE, FL 34946 PMre:772-4666799 EmalI:OUICKCALGS@AOL.COM Project Information For: SNOWE RESIDENCE External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.347/0.153 in H2O 0.214 in/100ft 1173 cfm 233 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.347 / 0.153 in H2O 0.214 in/100ft 1173 Gtm Name Design (Btuh) Htg (cfrn) Cl9 (GFm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 1905 41 84 0.238 5.0 Ox0 MFx 30.6 115.0 st2 BEDROOM c 3435 90 151 0.327 7.0 Ox0 MFx 11.0 95.0 BEDROOM c 3350 83 148 0.238 7.0 Ox0 VIFx 30.6 115.0 st2 GARAGE h 3286 268 145 0 0 Ox0 MFx 0 0 KrrHCENAIN. h 2247 84 67 0,227 7.0 ox0 MFx 38.2 115.0 st2 KITHCENIDIN: A h 2247 84 67 0.234 6.0 Ox 0 MFx 33.2 115.0 st2 LAUNDRY c 167 3 7 0.347 5.0 Ox0 VIFx 5.0 95.0 LIVING h 4114 154 113 0,224 6.0 0x0 MFx 40.0 115.0 st2 LIVING -A In 4114 154 113 0,214 TO Ox0 VIFx 47.0 115.0 st2 LIVNGIDINING-A c 6309 213 278 0.314 8.0 Ox0 MFx 15.7 95.0 Name Trunk Type Htg (cm) Clg (cfm) Design FIR Ueloc (fpm) Diam (in) HxW (in) Duct Mate al Tunk st2 PeakAVF 599 592 0.214 560 14.0 0 x 0 �/nlFlx aaalnar camas na�a aaar� manaany e�armdea �. '� W'19f1Y50f[a 2022-Feb-0312:14:45 ^.^^•n..�,�..^..��m�..�. RigN-Suie®Unversa1202121.0.08 RSW8101 Paget %�'� ...\GWCK\Doumerhs\WrigMsofl HVAC45NOWE RES..np CaIc=MJB Fronl Door faces: E Htg Clg TEL Design Ueloc Diam HxW Stud/Joist(cfm) E (cfin) (ft) FR i (in) (in) Opening (in) 556 50071.4 0.214 398 16.0 Ox 0 617 673 0 0 0 0 Ox 0 V1Fx eaelnano Dames nape aee� manuanr ezerdad�r, '�-wr7ghtsoftm zo2z-Feb-gs izaa:as f•A _=—��-rm RI91t-SJIe®Un�ersa12g2721.0.0e RSU08101 Page3 .9l.li ...14UICK\Daamerds\WrighLvoII HUACISNOWE RES..rtp Caic=MJB FrorY Doar hdces: E