HomeMy WebLinkAboutCertification For Design Load ComplianceINEW
r, rd; _' aZz' _ '�''? Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: M c. U;11; S
Project Address: L.)r S 9 5 Ne'Hc
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida (l�;%; Code Fifth Edition with 20 1 (o Supplements using ASCE 7-10
2. Structure Designed as (check one): )( Enclosed Partially Enclosed Open
3. Risk Category: _I ",e II III IV Exposure Category: B C )<__D
4. Design Wind Velocity 1 foS mph ASD XLRFD End Zone Width: ft
5. Mean Roof Height 22.0 ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 112,3 Zone 2: 73•6 Zone 3: 16 t. 9 Zone 4: 13'0•1 Zone 5: `1• S Garage: n.1 A
7. Design Loads: Floor: & 5 PSF Roof/Dead: 2 5' PSF Roof/Live: 30 Balcony: q6 PSF
Dock: P 1A PSF Deck: WA PSF Stairs: 10 PSF Fence: n/ A PSF Railings: 'Q A PSF
8. Were Shear Walls Considered For Structure? _Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? LC _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
/b
Signature, Ate, and Seal
Revised 07/25/2014
5l'Avn S%4n,��,w,(n &1950
Print Name Cert # & Co. Cert Auth.
C�.��n}4r. 1✓n9:nctr;n� Assoc(a�tSf=Ac.
300 Av G d� Cl..o. J; ans , at. 2G0
PAI. BcccL, &C.rIcAt, r-L 33Y1$
Company Name & Address