Loading...
HomeMy WebLinkAboutCertification For Design Load ComplianceINEW r, rd; _' aZz' _ '�''? Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: M c. U;11; S Project Address: L.)r S 9 5 Ne'Hc Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida (l�;%; Code Fifth Edition with 20 1 (o Supplements using ASCE 7-10 2. Structure Designed as (check one): )( Enclosed Partially Enclosed Open 3. Risk Category: _I ",e II III IV Exposure Category: B C )<__D 4. Design Wind Velocity 1 foS mph ASD XLRFD End Zone Width: ft 5. Mean Roof Height 22.0 ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 112,3 Zone 2: 73•6 Zone 3: 16 t. 9 Zone 4: 13'0•1 Zone 5: `1• S Garage: n.1 A 7. Design Loads: Floor: & 5 PSF Roof/Dead: 2 5' PSF Roof/Live: 30 Balcony: q6 PSF Dock: P 1A PSF Deck: WA PSF Stairs: 10 PSF Fence: n/ A PSF Railings: 'Q A PSF 8. Were Shear Walls Considered For Structure? _Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? LC _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: /b Signature, Ate, and Seal Revised 07/25/2014 5l'Avn S%4n,��,w,(n &1950 Print Name Cert # & Co. Cert Auth. C�.��n}4r. 1✓n9:nctr;n� Assoc(a�tSf=Ac. 300 Av G d� Cl..o. J; ans , at. 2G0 PAI. BcccL, &C.rIcAt, r-L 33Y1$ Company Name & Address