Loading...
HomeMy WebLinkAboutElevation Certificate 7-3-17U,r DEPARTMENT OF HOMELAND,, - .. > a' '� ` OMB No. 1660-0008. IweerullEmergency Management Age:;; Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1 9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) buiidino owner SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE A1. Building Owner's Name Policy Number. McGILLIS A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number: 595 NETTLES BLVD. CRY State ZIP Code JENSEN BEACH Florida 0 34957 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 595 NETTLES ISLAND PROJECT SECTION 2 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Latitude/Longitude: Lat. 27°1T13.1" Long. 80°13'23.6" Horizontal Datum: ❑ NAD 1927 x❑ NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 8 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosures) 37 sq ft b) Number of permanent flood openings in the crawispace or enclosure(s) within 1.0foot above adjacent grade 2 c) Total net area of flood openings in A8.b 400 sq in d) Engineered flood openings? x❑ Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage N/A sq It b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in . d) Engineered flood openings? ❑ Yes x❑ No SECTION B —FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State UNINCORP 120285 ST. LUCIE Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111 C 0311 J 02/16/2012 ' 02/16/2012 AE 6.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 139: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 x❑ NAVD 1988 ❑Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE 'r OMB No. 1660-0008 Expiration Date: November 39, 2018 IMPORTANT: In these spaces, copy tine corresponding information from Section A. - FOR INSURANCE COMPANY'USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number., S q S I.-At-True.s City State ZIP Code Ja0sl� ) ACH 1rc.orz.lr�a o 3ygs7 Company NAIC Number SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* x❑ Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, ARIA, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: 94 77 A04 FDOT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4.75 0 feet ❑ meters b) Top of the next higher floor 6.04 ❑x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only), N/A ❑ feet ❑ meters d) Attached garage (top of slab) N/A ❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building g,2 0 feet ❑ 'meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 4.6 0 feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 4.7 0 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 4A 0 feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. l certify that the information on this Certfficate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑ No Check here if attachments. Certifier's Name License Number EARLE R. STARKEY 004459 Title PROFESSIONAL LAND SURVEYOR PlaCr% Company Name ACCURIGHT LAND SURVEYING INC. Address 1501 DECKER AVENUE #419 I o 3 I t '] City State ZIP Code STUART Florida 0 34994 J>LS J y y s 9 Signature Date Telephone Ext. 07/03/2017 772-286-7694 paghis Elevation Certificate and all a a r 1) community official, (2) insurance agenticompany, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) A8-A IS A STORAGE ROOM A8-D SMART VENTS MODEL #1540-520 (200 SQ. IN.. EACH) C2-A STORAGE ROOM C2-E BOTTOM OF ELECTRIC PANEL FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page z or ti Building Photographs See Instructions for Item A6. Use: am 595 NETTLES BLVD. City State ZIP Code I C IV&W NAIC Number JENSEN BEACH FLORIDA 34957 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two Widing photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View° and "Rear View°; and, if required, "Right Side MeW and "Left side View.' ff submitting more photographs than will fit on this page, use the Continuation Page, following. FRONT 07/03/2017 REAR 07/03/2017 SIDE 07/03/2017 DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #154,0-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 i ICC ICC (P;*� c . ICC C— PMG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" e==': A Subsidiary of CODECOUNcii ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not '�e specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Awi RiC :N Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-2074 Reissued February 2015 Revised May 2016 This report is subject to renewal February 2017. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com infoC&smartvent.com I40toT_1%11C01►���1-�J*t6 SMART VENT" AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540470;#1540-574;#1540-524;#1540-514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012, 2009 and 2006 International Building Code® (IBC) ■ 2015, 2012, 2009 and 2006 international Residential Code® (IRC) ■ 2013 Abu Dhabi International Building Code (ADIBC)t tThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters. Certain models also allow natural'ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Vent® FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. Smart Vent® Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVENT® Stacking Model #1540-511 and FloodVENT® Stacking Model #1540-521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise_ and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 3.3 Ventilation: The SmartVENT® Model #1540-510 and SmartVENT® Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENTr" Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other FVs recognized in this report do not offer natural ventilation. 4.0 DESIGN AND INSTALLATION SmartVENT® and FloodVENT® are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. Installation clips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 200 square feet (18.6 m2) of enclosed area, except that the SmartVENT® Stacking Model #1540-511 and FloodVENT® Stacking Model #1540-521 must be installed with a minimum of one FV for every 400 square feet (37.2 M2) of enclosed area. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or anv other attributes not specifically addressed, nor are they to be construed as an endorsement ojthe subject ojthe repot a a recwnmendation jar its use. There is no warranty by iCC Evaluation Service, LLC, express or implied, as to anvjfnding or other matter in this report, or as to anv product covered by the report. Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. aniwimw cm[maac Page 1 of 3 ESR-2074 I Most Widely Accepte( — d Trusted ( Page 2 of 3 r ` ■ Below the base flood elevation. ` ti� 5.2 The Smart Vent;, -,,'Vs must not be used in the place ■ With the bottom of the FV located a maximum of of "breakaway walls" in coastal high hazard areas, but 12 inches (305.4 mm) above the higher of the final are permitted for use in conjunction with breakaway grade or floor and finished exterior grade immediately walls in other areas. under each opening. 6.0 EVIDENCE SUBMITTED 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report govern. Data in accordance with the [CC -ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015. 7.0 IDENTIFICATION The Smart VENT® models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR-2074). TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVENT 1540-520 15 /4" X 7 /4" 200 SmartVENT® 1540-510 153/4" X 73/4" 200 FloodVENT® Overhead Door 1540-524 153/4" X 73/4" 200 SmartVENT® Overhead Door 1540-514 153/4" X 73/4" 200 Wood Wall FloodVENT® 1540-570 14" X 83/4" 200 Wood Wall FloodVENT° Overhead Door 1540-574 14" X 83/4" 200 SmartVENT® Stacker 1540-511 16" X 16" 400 FloodVene Stacker 1540-521 16" X 16" 400 For SI: 1 inch = 25.4 mm; 1 square foot = mZ ESR-2074 I Most Widely AcceDWe 'd Trusted Page 3 of FIGURE 1—SMART VENT: MODEL 1540-510 FIGURE 2—SMART VENT MODEL 1540-520 FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN IMES Evaluation Report ESR-2074 FBC Supplement Reissued February 2015 Revised March 2016 This report is subject to renewal February 2017. www.1cc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—VentslFoundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877)441-8368 www.smartvent.com infoAsmartvent.com EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #15404.10, #1540-511; #1540-570; #1540-574; #1540.524; #1540-514 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate.that Smart Vene Automatic Foundation Flood Vents, recognized in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code —Building (FBC) ■ 2014 Florida Building Code —Residential (FRC) 2.0 CONCLUSIONS The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the FBC and the FRC, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report. Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the FBC and the FRC. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued February 2015 and revised May 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or anv other attributes not specifically addressed, nor are duT to be construed as an endorsement of the subject of the report or a reconnnendation for its use. There is no warranty by ICC Evahmtion Service, LLC, express or implied, as to anvfinding or other matter in this report, or as to arty product covered by the report. 1 l cmrcanac �.aoo Copyright© 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 1 MATERIAL REVIEW & MAINTENANCE INSTRUCTIONS Objective: When we set out to design our flood vent products, a comprehensive study was conducted to determine the most important design attributes that would be needed to insure that our customers received the best product available. Because our company started on the shores of the East Coast of New Jersey, everyone placed durability as their number one concern. Durability: After extensive research, including review of many less expensive materials, we choose to make the bulk of the components for our vents from stainless steel. Salt will pit stainless steel unless it is rinsed with water. We recommend that the vent be washed with fresh water twice a year. Any red rust or minor surface pitting can be removed with "commercial de -rusting solutions.". The mechanism that operates the automatic louvers on models 1540-M;b:, ;1540- 511, 1540-514 and 1540-550 is also entirely made from stainless steel, and water rinsing will reduce corrosion and dirt build-up. Prior to final inspection and testing, the louver mechanism is lubricated with a dry film lubricant. This over the counter lubricant should be applied at minimum one time per year, or when needed. Rinse the louver mechanism, let dry, then spray all of the moving parts. Note: Wet lubricants or grease will allow dirt and sand to accumulate on the moving parts. Use only dry film lubricants. The bi-metal coil is made from highly engineered materials. The composite contains a large portion of Nickel and the finished coil is secondarily heat -treated, which forms a protective barrier to protect it from the elements. A squirt of dry film lubricant into the coil chamber during maintenance will extend its life. The floats are manufactured from engineered plastics. An ultra -violet inhibitor was blended into the raw material before molding to insure that the sun does not degrade the functional or dimensional characteristics of the material. Insert a thin blade or a credit card into each side of the vent door's float slot, and the door will easily push open. Rinse the float cavity, then apply a small amount of dry film lubricant on the float, where it contacts the frame. Like any product, the care one gives will determine its life. We have used the best American materials, along with the best engineering and manufacturing professionals to build our products. With just a little care, your vents will function carefree for many years. www.smartvent.com 9 877-441-8368 ONE YEAR LIMITED WARRANTY LIMITED, NON -PRORATED AND TRANSFERABLE Any and all product(s) as manufactured by SMART VENT® are subject to a one year limited warranty in accordance with the following, provided that the products covered by this warranty have been installed in strict accordance with the SMART VENT® written installation instructions and in accordance with all local codes and standards. Cleaning and lubrication may be required, and is not covered by this warranty. SMART VENT® warrants to the original purchaser or a subsequent owner of the property that parts are free from manufacturing defects for 1 (one) year from the date of purchase. Security Clips must be installed to validate warranty. Should any defect occur during the one-year period following the date of purchase, SMART VENT® will provide a replacement for that part deemed to be defective (but not including labor costs incurred in removing the part, installing the replacement part, or shipping). In the event of replacement according to the terms of this warranty, the warranty on the replacement part will extend for the balance of the original warranty period, which is in effect at the time the part proves defective. LIMITATIONS SMART VENT® shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with painting, misuse, abuse, neglect or improper handling or storage, or installation not in strict adherence to SMART VENT° written instructions. SMART VENT® reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a result of such discontinuance or modification. If SMART VENT® replaces any part under this warranty, it may substitute parts designated by SMART VENT° to be of comparable quality or price range in the event the product initially installed has been discontinued or modified. OTHER CONDITIONS THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER ORAL OR WRITTEN WARRANTIES, LIABILITIES OR OBLIGATIONS OF SMART VENT®. PERTINENT STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME SUBSEQUENT TO SALE A CONSUMER/ HOMEOWNER MAY SEEK A REMEDY PURSUANT TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL SMART VENT@ BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN, RESULTING FROM THE BREACH OF ANY WARRANTY SET FORTH HEREIN. NO REPRESENTATIVE OF SMART VENT@ OR ITS DISTRIBUTORS OR DEALERS IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY. Lit-006 ART VENT www.smartvent.com • 877-441-8368