HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: McGillis Residence
Builder Name: JWN Builders LLC
Street: Lot 595 Nettles Island
Permit Office: St Lucie County
City, State, Zip: Jensen Beach, FL, 34957
Permit Number:
Owner: McGillis Residence
Jurisdiction: 611000
Design Location: FL, ST LUCIE_CO_INTL
County:: st. lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2296.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 2033.70 ft2
b. Frame - Wood, Exterior
R=19.0 262.50 ft2
3. Number of units, if multiple family 1
c. N/A
R= f?
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (906.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Roof Deck (Unvented)
R=19.0 906.00 ft2
6. Conditioned floor area above grade (ft2) 1606
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(336.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 300
a. U-Factor: Dbl, U=0.24 336.67 ft2
SHGC: SHGC=0.27
b: U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBhAr Efficiency
d. U-Factor: N/A f12
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.563 ft.
Area Weighted Average SHGC: 0.270 '
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (976.0 sqft.) Insulation Area
� EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 906.00 ft2
b. Conservation features
- b. Raised Floor R=19.0 70.00 ft2
None
c. N/A " y R= ft215.
Credits
s' CF, Pstat
Glass/Floor Area: 0.210 Total Proposed Modified Loads: 60.72 a
~PASS
Total Baseline Loans: 61.93 '��'� (t '2
_
„ns
I hereby certify that the plans and specifications covered by
r �o�' !it JHE sr
Review of the plans and "?9T
this calculation are in complian th the Florida Ene
specifications covered by this
061
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
DATE: 6
Before construction is completed
this building will be inspected for
a
compliance with Section 553.908
,
I hereby certify that this buding, as designed, is in compliance
Florida Statutes.
9�
O
f'O0
with the Florida Energy e.
WE'
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: - -
DATE:
- Compliance requires certification by.the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Co'mpliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test'report in accordance with R402.4.1.2.
10/3,1/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
McGillis Residence
User
McGillis Residence
1
JWN Builders LLC
St Lucie County
611000
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1606
Total Stories: 2
Worst Case: Yes
Rotate Angle: 135
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
Lot 595 Nettles Island
st. lucie
Jensen Beach,
FL, 34957
CLIMATE
/
v Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90
70
75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Bl0ck1
1606 14454
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1606 14454 Yes 4
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
2 Raised Floor
Main 128 ft 0
Main ---- ----
906 ft2
70 ft2
----
19
0 0 1
0 0 1
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 1057 ft2 0 ft2 Unfinishe
0.35
No 0.4
No 19 22.6
ATTIC
V #
Type
Ventilation . Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 976 ft2
N Y
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Main 0 Blown
906 ft2 0
Wood
10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar
Below
#
Cmt In
WAR Type1
Space
N=>SE Exterior
Concrete Block - Int Insul
Main
5
39
10 18
4
730.3 ft'
0
0.75
0
2
E=>SW Exterior
Concrete Block - Int Insul
Main
5
30
18
4
550.0 ft?
0
0.75
0
3
E=>SW Exterior
Concrete Block - Int Insul
Main
5
8
10
4
82.7 ft'
0
0.75
0
4
S=>NW Exterior
Concrete Block - Int Insul
Main
5
11
10
4
113.7 ft'
0
0.75
0
5
S=>NW Exterior
Frame - Wood
Main
19
16
2 8
4
134.7 ftz
0
0.75
0
6
SW=>N Exterior
Frame - Wood
Main
19
9
10 8
4
81.9 ftz
0
0.75
0
7
W=>NE Exterior
Frame - Wood
Main
19
5
6 8
4
45.8 ftz
0
0.75
0
8
W=>NE Exterior
Concrete Block - Int Insul
Main
5
21
0 10
4
217.0 ftz
0
0.75
0
9
W=>NE Exterior
Concrete Block - Int Insul
Main
5
11
4 10
4
117.1 ftz
0
0.75
0
10
W=>NE Exterior
Concrete Block - Int Insul
Main
5
16
10 8
4
140.3 ftz
0
0.75
0
11
S=>NW Exterior
Concrete Block - Int Insul
Main
5
8
10
4
82.7 ftz
0
0.75
0
DOORS
# Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 N=>SE Wood
Main
None
.2
.1
.1
.1 ftz
WINDOWS
Orientation shown is the entered orientation (=>) changed to Worst Case.
Wall
Overhang
v
# Omt ID
Frame Panes
NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
16.6 ftz
1 ft0 in
1 ft 0 in
None
None
2 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
16.6 ftz
1 ft 0 in
1 ft 0 in
None
None
3 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
5.1 ftz
1 ft0 in
1 ft 0 in
None
None
4 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
5.1 ft'
1 ft0 in
1 ft 0 in
None
None
5 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
13.5 ftz
0 ft 0 in
0 ft 0 in
None
None
6 N=>SE 1
Metal Low-E Double
Yes
0.24
0.27
13.5 ftz
0 ft 0 in
0 ft 0 in
None
None
7 E=>SW 2
Metal Low-E Double
Yes
0.24
0.27
16.6 ftz
1 ft 0 in
1 ft0 in
None
None
8 E=>SW 2
Metal Low-E Double
Yes
0.24
0.27
8.7 ftz
0 ft 0 in
0 ft 0 in
None
None
9 E=>SW 2
Metal Low-E Double
Yes
0.24
0.27
3.6 ftz
0 ft 0 in
0 ft 0 in
None
None
10 E=>SW 2
Metal Low-E Double
Yes
0.24
0.27
19.8 ftz
0 ft 0 in
0 ft 0 in
None
None
11 S=>NW 4
Metal Low-E Double
Yes
0.24
0.27
17.0 ftz
0 ft 0 in
0 ft 0 in
None
None
12 S=>NW 4
Metal Low-E Double
Yes
0.24
0.27
17.0 ftz
1 ft 0 in
1 ft 0 in
None
None
13 S=>NW 4
Metal Low-E Double
Yes
0.24
0.27
16.3 ftz
1 ft0 in
1 ft0 in
None
None
14 S=>NW 11
Metal Low-E Double
Yes
0.24
0.27
20.0 ftz
7 ft 0 in
2 ft 6 in
None
None
15 S=>NW 11
Metal Low-E Double
Yes
0.24
0.27
8.9 ftz
8 ft 0 in
2 ft 6 in
None
None
16 S=>NW 11
Metal Low-E Double
Yes
0.24
0.27
5.6 ft'
8 ft 0 in
0 ft 6 in
None
None
17 W=>NE 8
Metal Low-E Double
Yes
0.24
0.27
19.8 ftz
0 ft 0 in
0 ft 0 in
None
None
18 W=>NE 8
Metal Low-E Double
Yes
0.24
0.27
19.8 ftz
0 ft 0 in
0 ft 0 in
None
None
19 W=>NE 8
Metal Low-E Double
Yes
0.24
0.27
16.6 ftz
1 ft0 in
1 ft0 in
None
None
20 W=>NE 9
Metal Low-E Double
Yes
0.24
0.27
16.6 ftz
1 ft0 in
1 ft0 in
None
None
21 W=>NE 10
Metal Low-E Double
Yes
0.24
0.27
60.0 ftz
8 ft 0 in
1 ft 0 in
None
None
10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000286
1204.5 66.13 124.36 .264 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat
None
COPI 34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1 Central Unit
None
SEER: 16 35 kBtu/hr 1050 cfm 0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1 Electric Tankless
Main
0.99 1 gal 50 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply —
v # Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 300 ftz
Attic
80.3 f12 Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling[[ jj Jan [�j Feb Mar
Heatin[X] Jan H Feb XMar
Ventin [ ]Jan [ ]Feb XMar
Ceiling Fans:
W A r Ma rl Jun �Xj Jul ri Au X Se Oct
Apr IMay Jun Jul Aug, L I SeP � Oct
Apr May JunJul Au [ Se Oct
Nov
HX Nov
Nov
Dec
Dec
H Dec
10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
Thermostat Schedule:
Schedule Type
HERS 2006
Reference
1
2
3
4
5
Hours
6
7
8
9
10
11
12
Cooling CND)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energyperformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows**
Description
a. U-Factor:
Dbl, U=0.24
SHGC:
SHGC=0.27
b. U-Factor:
N/A
SHGC:
c. U-Factor:
NIA
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
Lot 595 Nettles Island, Jensen Beach, FL, 34957
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0
2033.70 ft2
b. Frame - Wood, Exterior
R=19.0
262.50 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Roof Deck (Unvented)
R=19.0
906.00 ft2
1606
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
336.67 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 300
ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
35.0
SEER:16.00
ft2
2.563 ft.
0.270
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 906.00 ft2
b. Raised Floor R=19.0 70.00 ft2
c. N/A R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code j4mpliantfeftures.
Builder Signature: Date: �f��L�
Address of New Ho : ����� 4/vO City/FL Zip:
kBtu/hr Efficiency
34.0 COP:1.00
Cap: 1 gallons
EF: 0.99
CF, Pstat
THE STglF
p�s+
COD WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1