Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: McGillis Residence Builder Name: JWN Builders LLC Street: Lot 595 Nettles Island Permit Office: St Lucie County City, State, Zip: Jensen Beach, FL, 34957 Permit Number: Owner: McGillis Residence Jurisdiction: 611000 Design Location: FL, ST LUCIE_CO_INTL County:: st. lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2296.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 2033.70 ft2 b. Frame - Wood, Exterior R=19.0 262.50 ft2 3. Number of units, if multiple family 1 c. N/A R= f? 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (906.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Roof Deck (Unvented) R=19.0 906.00 ft2 6. Conditioned floor area above grade (ft2) 1606 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(336.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 300 a. U-Factor: Dbl, U=0.24 336.67 ft2 SHGC: SHGC=0.27 b: U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBhAr Efficiency d. U-Factor: N/A f12 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.563 ft. Area Weighted Average SHGC: 0.270 ' 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (976.0 sqft.) Insulation Area � EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 906.00 ft2 b. Conservation features - b. Raised Floor R=19.0 70.00 ft2 None c. N/A " y R= ft215. Credits s' CF, Pstat Glass/Floor Area: 0.210 Total Proposed Modified Loads: 60.72 a ~PASS Total Baseline Loans: 61.93 '��'� (t '2 _ „ns I hereby certify that the plans and specifications covered by r �o�' !it JHE sr Review of the plans and "?9T this calculation are in complian th the Florida Ene specifications covered by this 061 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: 6 Before construction is completed this building will be inspected for a compliance with Section 553.908 , I hereby certify that this buding, as designed, is in compliance Florida Statutes. 9� O f'O0 with the Florida Energy e. WE' OWNER/AGENT: BUILDING OFFICIAL: DATE: - - DATE: - Compliance requires certification by.the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Co'mpliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test'report in accordance with R402.4.1.2. 10/3,1/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: McGillis Residence User McGillis Residence 1 JWN Builders LLC St Lucie County 611000 Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1606 Total Stories: 2 Worst Case: Yes Rotate Angle: 135 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 595 Nettles Island st. lucie Jensen Beach, FL, 34957 CLIMATE / v Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Bl0ck1 1606 14454 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1606 14454 Yes 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 2 Raised Floor Main 128 ft 0 Main ---- ---- 906 ft2 70 ft2 ---- 19 0 0 1 0 0 1 ROOF / V # Roof Gable Roof Type Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1057 ft2 0 ft2 Unfinishe 0.35 No 0.4 No 19 22.6 ATTIC V # Type Ventilation . Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 976 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 906 ft2 0 Wood 10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Cmt In WAR Type1 Space N=>SE Exterior Concrete Block - Int Insul Main 5 39 10 18 4 730.3 ft' 0 0.75 0 2 E=>SW Exterior Concrete Block - Int Insul Main 5 30 18 4 550.0 ft? 0 0.75 0 3 E=>SW Exterior Concrete Block - Int Insul Main 5 8 10 4 82.7 ft' 0 0.75 0 4 S=>NW Exterior Concrete Block - Int Insul Main 5 11 10 4 113.7 ft' 0 0.75 0 5 S=>NW Exterior Frame - Wood Main 19 16 2 8 4 134.7 ftz 0 0.75 0 6 SW=>N Exterior Frame - Wood Main 19 9 10 8 4 81.9 ftz 0 0.75 0 7 W=>NE Exterior Frame - Wood Main 19 5 6 8 4 45.8 ftz 0 0.75 0 8 W=>NE Exterior Concrete Block - Int Insul Main 5 21 0 10 4 217.0 ftz 0 0.75 0 9 W=>NE Exterior Concrete Block - Int Insul Main 5 11 4 10 4 117.1 ftz 0 0.75 0 10 W=>NE Exterior Concrete Block - Int Insul Main 5 16 10 8 4 140.3 ftz 0 0.75 0 11 S=>NW Exterior Concrete Block - Int Insul Main 5 8 10 4 82.7 ftz 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>SE Wood Main None .2 .1 .1 .1 ftz WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 16.6 ftz 1 ft0 in 1 ft 0 in None None 2 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 16.6 ftz 1 ft 0 in 1 ft 0 in None None 3 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 5.1 ftz 1 ft0 in 1 ft 0 in None None 4 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 5.1 ft' 1 ft0 in 1 ft 0 in None None 5 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 13.5 ftz 0 ft 0 in 0 ft 0 in None None 6 N=>SE 1 Metal Low-E Double Yes 0.24 0.27 13.5 ftz 0 ft 0 in 0 ft 0 in None None 7 E=>SW 2 Metal Low-E Double Yes 0.24 0.27 16.6 ftz 1 ft 0 in 1 ft0 in None None 8 E=>SW 2 Metal Low-E Double Yes 0.24 0.27 8.7 ftz 0 ft 0 in 0 ft 0 in None None 9 E=>SW 2 Metal Low-E Double Yes 0.24 0.27 3.6 ftz 0 ft 0 in 0 ft 0 in None None 10 E=>SW 2 Metal Low-E Double Yes 0.24 0.27 19.8 ftz 0 ft 0 in 0 ft 0 in None None 11 S=>NW 4 Metal Low-E Double Yes 0.24 0.27 17.0 ftz 0 ft 0 in 0 ft 0 in None None 12 S=>NW 4 Metal Low-E Double Yes 0.24 0.27 17.0 ftz 1 ft 0 in 1 ft 0 in None None 13 S=>NW 4 Metal Low-E Double Yes 0.24 0.27 16.3 ftz 1 ft0 in 1 ft0 in None None 14 S=>NW 11 Metal Low-E Double Yes 0.24 0.27 20.0 ftz 7 ft 0 in 2 ft 6 in None None 15 S=>NW 11 Metal Low-E Double Yes 0.24 0.27 8.9 ftz 8 ft 0 in 2 ft 6 in None None 16 S=>NW 11 Metal Low-E Double Yes 0.24 0.27 5.6 ft' 8 ft 0 in 0 ft 6 in None None 17 W=>NE 8 Metal Low-E Double Yes 0.24 0.27 19.8 ftz 0 ft 0 in 0 ft 0 in None None 18 W=>NE 8 Metal Low-E Double Yes 0.24 0.27 19.8 ftz 0 ft 0 in 0 ft 0 in None None 19 W=>NE 8 Metal Low-E Double Yes 0.24 0.27 16.6 ftz 1 ft0 in 1 ft0 in None None 20 W=>NE 9 Metal Low-E Double Yes 0.24 0.27 16.6 ftz 1 ft0 in 1 ft0 in None None 21 W=>NE 10 Metal Low-E Double Yes 0.24 0.27 60.0 ftz 8 ft 0 in 1 ft 0 in None None 10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 1204.5 66.13 124.36 .264 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPI 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 35 kBtu/hr 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Main 0.99 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — v # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 300 ftz Attic 80.3 f12 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Cooling[[ jj Jan [�j Feb Mar Heatin[X] Jan H Feb XMar Ventin [ ]Jan [ ]Feb XMar Ceiling Fans: W A r Ma rl Jun �Xj Jul ri Au X Se Oct Apr IMay Jun Jul Aug, L I SeP � Oct Apr May JunJul Au [ Se Oct Nov HX Nov Nov Dec Dec H Dec 10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling CND) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energyperformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Dbl, U=0.24 SHGC: SHGC=0.27 b. U-Factor: N/A SHGC: c. U-Factor: NIA SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: Lot 595 Nettles Island, Jensen Beach, FL, 34957 New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=5.0 2033.70 ft2 b. Frame - Wood, Exterior R=19.0 262.50 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Roof Deck (Unvented) R=19.0 906.00 ft2 1606 b. N/A R= ft2 Area c. N/A R= ft2 336.67 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 300 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 35.0 SEER:16.00 ft2 2.563 ft. 0.270 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 906.00 ft2 b. Raised Floor R=19.0 70.00 ft2 c. N/A R= ft2 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code j4mpliantfeftures. Builder Signature: Date: �f��L� Address of New Ho : ����� 4/vO City/FL Zip: kBtu/hr Efficiency 34.0 COP:1.00 Cap: 1 gallons EF: 0.99 CF, Pstat THE STglF p�s+ COD WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/31/2016 7:46 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1