Loading...
HomeMy WebLinkAboutKSN Engineering & Testingr-� A%L­3AW KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGIN ERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 January 18, 2017 JWN Construction 1701 S.E. Carvalho Street Port St. Lucie, Florida 34983 PC rL4(rt -e -� --A-- / L I ) - 0l ! 7 RECEIVED Re: Pile Installation Inspection 595 Nettles Boulevard FEB / 2 2017 Nettles Island Jensen Beach, Florida KSM Project #: 170183-pile Dear Sir: As requested, we were present during the installation of the twenty (20) auger - cast -piles for the proposed project at the referenced site. Pile layout by others. The pile installation inspection was generally performed in accordance to the "Inspector Guide to the Auger Cast -In -Place Piles", published by the Auger Cast - In -Place Pile Committee of The Deep Foundation Institute. Based on this inspection, it is our professional opinion, that the piles constructed for the referenced project were installed as specified on the construction drawings. The pile documentation and Location Plan are attached. Du on this phase of your project. III. JEK:cc E-mail To: jwnconstructon@bellsouth.net If you Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 T� Tip Clk9 A% L-3iva KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 569 FAX (772) 589-6469 ile Installation Inspection McGillis Residence 595 Nettles Boulevard Nettles Island Jensen Beach, Florida KSM Project #: 170183 Date Installed: January 13, 2017 Pile Location Pile Diameter Pile Length Pile Reinforcement Pump Strokes Truck No. Time Installed 1 14" 27' 5 - #5 Vertical 31 25756 9:56 2 w/ #4 Ties at 12" 35 25756 10:06 3 it ito.c. and 30 25756 10:15 4 it it1 - #7 Vertical 35 25756 10:27 5 it ItFull Depth of Pile 34 64624 10:58 6 It it It34 64624 11:07 7 it it 9133 64624 11:16 8 it it it29 64624 11:25 9 19 99 it35 65283 11:50 10 " it it 33 65283 12:00 11 it it it32 65283 12:08 12 It it It36 65283 12:18 13 it 19 it32 26410 12:42 14 it99 it36 26410 12:49 15 it if It32 26410 12:58 16 19 It It33 26410 1:07 17 It 35 25756 1:45 18 It It It 32 25756 1:54 19 19 is 9934 25756 2:01 20 It 91 it35 25756 2:08 Note: 1. 1 Pump Stroke = 1.07 cu.ft of Grout 2. Grout 28 Days Compressive Strength = 5,000 psi Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 12 15 11 A`� - - 714 ! ff'T`I f I �_ �Ron'oauarariwr. nip/ EI_ a 14 17 �- I. n _ 6 Y - 116 I --- .7 10 I r� r r l EEEEr E.E QI�� E. b Jll I ,¢, 1 � BATHRM FILE ^ OPY I "m L4 q� LOCATION OF PILES PROJECT: 595 Nettles Blvd, Jensen Beach, Florida SHEET I OF 1 YEMIN I ERINID&4WNBY.• S.G. J PERMIT #: DESIGNEDBY.. J.K. PROJECT #: 170183 pil AL ANOTESTIN DATE: 20170118 SCALE: NONE