Loading...
HomeMy WebLinkAboutMaster Anchoring PlanTHRU TIE -DOWN STRAP FLOOR JOIST 1/2' GRADE 6 BOL� M7TIi WASHERS TIE -DOWN STT7lW (1) 4x4 SYP #2 ON 8' WIDE OR LESS. (SEE NOTES) (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS 1/2'x3 (4.000 LB.) CONCRETE ALL ELSE(CAN BE SET ON GROUND). WEDGE ANCHOR WffH WASHER TIE -DOWN STRAP BOLTED TO TYPE ■ 3 ANCHOR RH 1/2' GRADE 5 a • BOLT MINI UM W(TH WASHERS 1/2'x3" (4,000 LB.) CONCRETE WEDGE ANCHOR WITH U-CHANNEL r72 NG 4' CONCRETE (TYPE 3) EXISTING 4" CONCRETE 2x4' SOLE PLATE (NATURALLY 1/2'x3" (4.000 Le.) CONCRETE DURABLE WOOD OR PT.) ' WEDGE ANCHOR WITH 2' WASHER GRADE i-a\1'\--�------T ��4„ `EXISTING 4' CONCRETE TIE -DOWN STRAP BOLTED DE 5 FLOOR JOIST 1/2" GRADE 6 FLOOR 1 ON 8' WIDE OR LESS, O 4x4 SYP BOLT MINIMUM WITH WASHERS M 1) (2) 2x6 OR (1) 4x6 P.T. SYP e2 SKIDS (NUT & BOLT OR LAG BOLT) ALL ELSE(CAN BE SET ON GROUND). TIE -DOWN STRAP BOLTED TO TYPE 3 ANCHOR RH 1/2' GRADE 6 BOLT MINI UM WITH WASHERS 1/2"% (4.000 LB.) CONCRETE I xA WEDGE ANCHOR WffH U-CHANNEL (TYPE 3)y. 1/2"x3" (4,000 LB.) CONCRETE WEDGE ANCHOR WITH 2' WASHER EXISTING 4" CONCRETE 1/4'x1}' LAG BOLT 0 if O.C. MAX. 2x6 P.T. SOLE PLATE - ---------- -- 7 GRADE —EXIsnNG 4' CONCRETE 1 /2'x5" (4,000 LB.). CONCRETE 2x4 SOLE PLATE (NATURALLY WEDGE ANCHOR WITH 2' WASHER DURABLE WOOD OR P.T.) GRADE A OPTIONAL REINFORCED l■"' CONCRETE FOUNDATION I-8"--! (1) 4x4 SYP #2 ON 8' WIDE OR LESS. (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ALL ELSE(CAN BE SET ON GROUND). TIE -DOWN STRAP OR 3/16" GALVANIZED STEEL CABLE (SEE NOTES) 1/2"x3" (4,000 LB.) CONCRETE I`A WEDGE ANCHOR WITH 2" WASHER 1�\I EXISTING 4" CONCRETE 1 � TIE -DOWN STRAP.TBOLTED TO -- (2) 2x6 OR (1) 4x8 P.T. SYFj GROUND ANCHOF}�WfTH 11//•2i,;�„_._ = - -,� �`-- � _Atl ELSE(CAN BE 01 2" WIDE 11 GAGE STEEL 'L' GRADE 5 BQLT-MMINIMMUM V1TTH - _. ��_. .a-� _ - BRACKET TIE -DOWN STRAP BOLTED THRU FLOOR JOIST (1) 4x4 SYP J2 ON 8' WIDE OR LESS. WASHERS. ALSO CONTINUOUS AA D - - ATTACHED TO GROUND ANCHOR �__---- --- WITH 1/2' GRADE 5 BOLT (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ON-OPPO IT `SIDE -- MINIMUM WITH WASHERS (NUT & BOLT OR 2j'LAG BOLT) ALL ELSE(CAN BE SET ON GROUND). 5/8' x 301.,_EARTH:-J_J�CHO'R`'4-P-.- I.i1 AUGER STYLE FOR-SOIL/CLAY DRIVE STYLE FOR ROCK/CORAL -:�•„L 1/2-x3' (4.000 LB.) CONCRETE WEDGE ANCHOR WITH 2" WASHER 'EXISTING:=4C=CO_NCRETEOR SUPPORT a _ (P.T. WOOD. CONCRETE BLOCK OR N_ ban\- Ao AT W_n• Uax 4• CONCRETE 1111 - ----- - - Tl. =1- OWN-1-J.FT—A.1FS- ANCHOR SPACING IS DESIGNED AS PER ASCE-7. ALL MEASUREMENTS ARE CENTER —TO —CENTER. TIE —DOWN STRAPS TO BE MINIMUM 1-4" x 0.035" GALVANIZED STEEL, FEDERAL SPECIFICATIONS DOS-7B1—H, TYPE-1, FINISH—B, GRADE-1. TIE —DOWN STRAPS OR CABLE AND CONNECTING HARDWARE TO HAVE 4,725 LB. MINIMUM ULTIMATE CAPACITY (3,160 LB. x 1.5). ALL EARTH ANCHORS SHALL HAVE A MINIMUM 4,300 L.B. CAPACITY. EARTH ANCHORS LOCATED AT EACH CORNER, MAXIMUM 16" FROM END (4 MINIMUM PER BUILDING), AND SPACED AS PER TABLE 2A,B,C DEPENDING ON SHED WIDTH, WIND SPEED, AND EXPOSURE. ANCHORS NOT NEEDED ON ENDS. CONCRETE ANCHORS TO BE SPACED AS PER TABLE 1A,B,C DEPENDING ON SHED WIDTH, WIND SPEED, AND EXPOSURE. CONCRETE ANCHORS TO HAVE A MINIMUM OF 4" COVER (DISTANCE FROM ANCHOR TO EDGE OF CONCRETE). MINIMUM SOIL BEARING CAPACITY IS 2,000 PSF (TYP.) EARTH ANCHORS AND CONCRETE ANCHORS MAY BE USED IN CONJUNCTION PROVIDED THAT THE SAME MAXIMUM SPACING IS FOLLOWED FOR EACH ANCHOR TYPE. 0. CONCRETE BLOCKS CAN BE OPTIONALLY CAPPED WITH APPROVED ABS CAP BOARDS (OLJVER TECHNOLGIES, INC. MODEL#OTICBI, OTIC132 OR EQUIVALENT) 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 4B" WITHOUT REINFORCING. i r�1 i TYPE 1 c: TYPE 2A 30" DRIVE 30' AUGER ANCHOR ANCHOR FOR ROCK/CORAL FOR SOIL/CLAY OQ DO - TYPE 3 TYPE 2B CONCRETE ANCHOR 30" AUGER WITH EXPANSION FOR ANCHOR SOIL/CLAY BOLT TIE -DOWN STRAP SECURED WITH (8) 1000.5" NAILS 5/8" 'x 30" EARTH ANCHOR. - AUGER STYLE FOR SOIL/CLAY, DRIVE STYLE FOR ROCK/CORAL TIE -DOWN STRAP BOLTED THRU FLOOR JOIST 1/2' GRADE 5 BOLT MINI uM WITH WASHERS (NUT & BOLT OR 2}'LAG BOLT) 5/8' x 30' EARTH ANCHOR WITH EYE HOLE: AUGER STYLE FOR'SOIL/CLAY, DRIVE STYLE FOR ROCK/CORAL TIE -DOWN STRAP (SEE NOTES) TIE -DOWN STRAP BOLTED TO iUND ANCHOR WITH 1/2" GRADE' 5 BOLT MINIMUM WITH WASHERS 5/8' x 30' EARTH ANCHOR: AUGER STYLE FOR SOIL/CLAY, DRIVE STYLE FOR ROCK/CORAL 'TABLE 2B - 140C 30" AUGER ANCHOR SPACING SHED WIDTH MAXIMUM ANCHOR SPACING UP TO 16'-0" 1o'-0" 16'-1" TO 24'-0" TABLE 2A - 170D 30" AUGER ANCHOR SPACING SHED WIDTH MAXIMUM ANCHOR SPACING UP TO 16'-0" 10'-0" 16'-1" TO 20'-0" 8'-0. O'-1" TO 24'-0' 6'-0" TABLE 2C - 120C 30" AUGER ANCHOR SPACING SHED WIDTH MAXIMUM ANCHOR SPACING UP TO 24'-0" 10'-0" (1) 4x4 SYP #2 ON 8' WIDE OR LESS. (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ALL ELSE(CAN BE SET ON GROUND). OPTIONAL SUPPORT PAD (P.T. WOOD, CONCRETE BLOCK OR PAD) SPACED AT 8'-0' MAX. (1) 4x4 SYP 12 ON 8' WIDE OR LESS. (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ALL ELSE(CAN BE SET ON GROUND). E)OSTING 4' CONCRETE OR OPTIONAL SUPPORT PAD (P.T. WOOD, CONCRETE BLOCK OR PAD) SPACED AT B'-O' MAX. (1) 4x4 SYP 02 ON 8' WIDE OR LESS (2) 2x6 OR (1) 46 P.T. SYP 82 SKIDS ALL ELSE(CAN BE SET ON GROUND). 'I GRADE OPTIONAL SUPPORT PAD (P.T. WOOD, CONCRETE BLOCK OR PAD) SPACED AT 8'-D" MAX. TABLE 1 A - 120C ANCHORING TO CONCRETE SHED WIDTH MAXIMUM ANCHOR SPACING 24'-0" 61-0" 20'-0" 7 -0" 16'-0" 7'-6" 14'-0" 8'-0" 12'-0" 10'-0" 12-0" 6'-0" 12'-0„ TABLE 1 B - 140C ANCHORING TO CONCRETE SHED WIDTH MAXIMUM ANCHOR SPACING 24'-0" 4'-0" 20'-0" 6—al 16'-0" 5'-6" 14'-0" 6—o" 12'-0" 7'-6" 10'-0" 8'-6" 8'-01, 12'-0„ 6'-0" 12'--0" ANCHORING TO CONCRETE SHED WIDTH MAXIMUM ANCHOR SPACING 24'-0" 3'-6" 20'-0" 16'-0" 50" 14'-0" 5'-6" 12'-0" 7-0" 10'-0" 8'-0" 8'-0" 6'-0" 12'-0" CODE VERSION ASCE-�-1e MANUFACTURER LARK BUILDERS BUILDING TYPE OF RED 1D11 1 G RESID LAVM STORAGE CONSTRUCTION TYPE V-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UnUTY ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED V.-120/M/170mph EXPOSURE D ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.1e IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 3OP5F OR 3001b POINT LOAD FLOOR DEAD LOAD IOPSF FLOOR LIVE LOAD 5OPSF 'R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE No SQUARE FOOTAGE 719 SO.Fr. OR LESS 2020 FBC 8 Z a CD z O 1 /4/21 z Q Ld Matthew T. Baldwin P.E. (n Florida License #64608 Sheet: AP-1 OF 1 W F