Loading...
HomeMy WebLinkAboutBuilding PlansPll. P-6A I SOLENOID VALVE i FUEL GAS RISER DIAGRAM JMETR!C - SCALE NOTE: MAINTAIN MINIMUM 10'-0" CLEARANCE FROM VENT TERMINALS ABOVE ROOF TO O/A INTAKE HOODS OF ROOFTOP HVAC EQUIPMENT. WASTE/VENT RISER DIAGRAM S"METRIC -- NOT TO SCALE J1' 2" V.T.R. � I i � NI i I i HAND `4I 3" V.T.R. � I HAND SINK I P-6B NI NI I N �I P-12 P-1H \ ��P 3 P-6 P-2H P6 - SOLENOID VALVE 1 /I DIRT LEG 40�1 ��15 o� 416N ti FUEL GAS RISER DIAGRAM ;O - %I NOT TO SCALE P-14 '3° P-3 I P-14 ti11 sf" I C'4 P-2 ti2C-4I � � r P-6 i (6) P-2 NOTE: I� I PP=1 MAINTAIN MINIMUM 10'-0" CLEARANCE FROM VENT TERMINALS ABOVE ROOF I TO O/A INTAKE HOODS OF ROOFTOP P-5 P-6 I HVAC EQUIPMENT. I P-1H I I �1 4h P-2H H P-2 y < I P 6 �� I - P-14 I C-4 -L4 g1 P-2H P-1H 3" I P-1 WASTE/VENT RISER DIAGRAM ISOMFTRIC -- NOT 10 SCALE Gregory fngineering, Inc. Innovative design solutions for engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 y I P-15 ��� 3° V.T.R. �N1 �I I 1 �I N 1 ~1 I I `-1 I P-6 2 I I I P-3 i ¢ry P-3 I I P_1 P-12 P-5 N _ I P-6 PP=11 P-1H 6' P-2H I Im I pCD C1i z _o,W U U w w Y--1 wLL w Q LLJ I - z a -, i S DRAWING IS AN INSTRI E N, OF rRVICF AND I HF PROPERTY OF HASI-IAM DESIGN GROUP. AND SIIAI I FFMAIN 1!IEIR ROP[R]Y 'HE OSE OF THE DRAWING IS RFSTRICI,D TO THE ')RIGINA1 SJE FOR WHIH D CS PREPAREAND F JPI II.AFION TFIERi O1 IS Eu r;SEY IIIED FU SIC: USF_ BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 ..... ...... - ------ ------- ...... ------ ------ --- - ----- - - ---- - ------- - - - - ------- ------ ------ ---- ------ ------ -- -- ------ ------ ------- ------ ------- --- ------ ------ - ------ --------- ------ - - ------ -- ------- ----- ------ - ----------------- - - - ---------- --- - -- ----------------- ----------------- ---------- ---- ------ ---- ------ -- - -- - - -- --- ----- ---- ---- 4� - - -- ----- /o -1 . F- el o 8 ----------- --- < 4'8 <-- L'] ii qx8 x . . .... ... .. --------------- III -TT- 14xL6 III 2x1 6' TF x x --- ----- - ---- ----- ---------- .................... I —A ---- ------- -4L EXISTING \CANOPY HOOD TO REMAIN P EXISTING CANOPY HOOD MAKE-U FAN AND DUCTWORK TO REMAIN C�! 30x22 x l _ �.-1 L CD I 72x 3 R/A GRILLE EXISTING CANOPY HOOD EXHAUST X FAN AND DUCTWORK TO REMAIN (TYPICAL OF 2) - -- - - ---- ------ - - ---- J - -- - -- ------ ----- - ---- --- - ----- - --- L. I 2xl -- --T ----------- 0 20x1 0 CN +31 0 CI x 00 CID - - ---- ----- x 1 F- ox8 L148 LI-L4 10X8 ------ ------- L -J L -J L .--J L -1 2-x 10 1 L 1:T - -- - ------ --D-- -- ]-I - - ---- ------- .... ...... ------- ---- --- ..... — — — — — — — — — — -- ------ ------ ------- ------ --- ------ ------- ------ ------ ------- ---- ------- ------ ------ -- ------ ------ ------- ---- .. ......... ---- — ------ ------------------------ ------------- -------------------------------- - -------------------- - - --- -- - ---- ------------------- --- -7 r77. El 22x10 2,240 E E L::Lj 12xb---- ------ ------- ---- ------- ----- n- ---- ------ ------ ------- I-u 0011114Z (AHU-1) TO BE REPLACED; DUCTWORK TO REMAIN — (ADDITIVE ALTERNATE) > 0 x x-- -- - ------ ---- - - -- - ------ ---- ------ -- - -- ------ - - - ------ U x CN ------ ------ x Nj 00 II x III I 00 EXISTING 4-TON AIR HANDLER - - - ------ - ------ --- --- -- -- -- -- - ------ -- --- --- ---- /< x < CD (AHU-2) TO BE REPLACED;III DUCTWORK TO REMAIN < (ADDITIVE ALTERNATE) A \> II ro �x 0-0 8 20x8 2:2�10 ifX - - ------ -------- --- --- ------ - ---- - ------ ------ ------ ------- ------ -- - - ------ ...... ------- ------ !Tgry__Eppi-ne-odog!.-I Ic -. Innovative design solutions or engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 -- ------- --- LEI' — — - ---- ---- - ------- ---- - - - ------- - - - - - - - - - - - I III I �� '� �� -�! j � I I I I I �I I - --------- ---- ----- X II CD CD -- — — — — — — — — — — — — — — — — — — — — — — -- — — — — — — — — ---- THESE PLANS AND ALL PROPOSED WORK i III ARE SUBJECT TO ANY CORRECTIONS REQUIRED III FIELD INSPECTORS THAT - --- - --- F - - - --- ------ ----- - ---- ---- - MAY BE NECESSARY fiq ORDz-R TO CD COMPLY WITH ALL APPLICABLE CODES. I II! � i -� E- .: X ! I I, i III II III III .' ..I ! \,\ \\ r CD 41\ ix — — — — — — — -- — — — — — --- — — — — III x \ \ \\\ -' BI —� p 146 . . . . . . . . . . ----- - - ----- - -- - --------------- I I L --] MECHANICAL DEMO FLOOR PLAN MEMO M Z 0 Cf) LLj 0 Z' THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 4 4 BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic.Nos.: AA26000586 LC26000508 DRAWN BY WMG CHECKED BY WMG DA 3-26-2014 JOB NO. 13-40 SCALE: 1 /811 = I 1 -01, SHEET NO. AO% Gregqry..Eo.gi.00-er-ing,--,Ip.q, Innovative design solutions for engineered building systems 4567 Deep River Place Jack-,onville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 'HESE PLANS AWU ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSk, RY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. U`� MECHANICAL DEMO ROOF PLAN SCALE: 1 /8 i' -- 0" DD Z 0 IL L'i o Z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN CROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH T IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. Iq ki BASHAM & LUCAS DESIGN GROUP,, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic.Nos.: AA26000586 LC26000508 04"" G E.Aj �4 No %% 0 DRAWN BY WMG CHECKED BY WMG DATE 3-26-2014 JOB NO. 13-40 SHEET NO. ff- M0,82 I ., ------------ li W�iZ A� ........... >. T uij urm 300 12"0 TM Al-18x18 425 CFM Gregory Engineering,Inc. innovative design solutions for engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 C" 1 `�/ x °a< o J, : D-20x6 D-20x6e 400 CFM 400 CFM, RK D-20x6'a AFL{ 400 CFM opOSEC 'o a`1 'E SU ,IECT TO ApjY CC)RRE �� f��'r�B��� CTICi�g 1 Ox 12 1P9SPECT0RS THAT MAY BE NECESS� , � O'W LY WITH ALL A PL9CABLE CIF — t ✓ J m a -� - - MECHANICAL FLOOR PLAN SCALE: 1 /8" = 1'-01, m i I o o_ V r—� w I w 1-- THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. & L UICAS DESIGN GROUP, INC. 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 W m s S d tl a 3 . 01, Mull W DRAWN BY WMG _ CHECKED BY WMG DATE 3-26-2014 JOB NO. _ 13-40 M I NEW 15- WI TH CU (ADDITIV NEW 20- WI TH CU (ADDITIV MECHANICAL ROOF PLAN SCAi_E: 1/8 11 = 1'-0" p lz�:'py Aii PROPOSED WORK CORRECTIONS SPECTORS THAT Wopnmo "r-`y vvi rH ALL ARPLICA LE CO ®ES. m m Z 0 c� �C) �o w W Q 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. �f BASHAM- & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 aa� v®0o"�"�Q w eN wIC y w u s 00 4& A hjy,E t$A!sdv"y DRAWN BY WMG CHECKED BY WMG - - DATE 3-26-2014 JOB NO. 13-40 SHEET NO. � e CD I o 0 w o w I w Q 0 o I z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM LUCAS DESIGN GROUP, VNI C. PLANNING -ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 o", v��., gx�w safl BN 4p as w a e o 'i`40p'0'. 7 DRAWN BY WMG CHECKED BY WMG DATE 3-26-2014 JOB NO. 13-40 E' V0. m 1. 0 >- m7ED C a~ z o w � a--� w U w o CD v w � 1--a w z Q J w oLn n oaz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 1 BASH"AM LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 ro Ip4 ,1+- sr e " T �a, A ✓° R ✓✓p%r a�.� iliBf lttl'1'0�7 DRAWN BY WMG CHECKED BY WMG DATE 3-26-2014 JI oB 1 -40 SHEET NO. -m 1,04 F EXHAUST FAN SCHEDULE DESIGNATION E F-1 E F-2 EF-3 FAN TYPE CEILING CENTRIFUGAL ROOF CENTRIFUGAL ROOF CENTRIFUGAL DRIVE TYPE DIRECT DIRECT DIRECT AIRFLOW (CFM) 50 650 650 EXT. STATIC (in wg.) 1/4" 1/4" 1/4" FAN SPEED (RPM) 929 847 847 INPUT (Watts) 26W 1/6 HP 1/6 HP VOLTAGE/PHASE 120/1 12011 120/1 ACCESSORIES A B,C A,B,C,D,E A,B,C,D,E CONTROL TYPE SEE NOTE 1. SEE NOTE 2. SEE NOTE 3. MANUFACTURER LOREN COOK: LOREN COOK LOREN COOK MODEL NO. GC-142 120C10D 120C10D NOTES CONTROL TYPE 1. CEILING -MOUNTED MOTION SENSOR CONTROL WITH 15-MIN TIME -DELAY RELAY. 2. INTERLOCK WITH RTU-2 EVAP FAN MOTOR. 3. INTERLOCK WITH RTU-3 EVAP. ACCESSORIES. _ FAN MOTOR. A. BACK DRAFT DAMP R. B. DISCONNECT SWITCH. C. SOLID STATE SPEED CONTROLLER. D 18" FACTORY ROOF CURB. E. AL.UMINUM BIRD SCREEN. VRF HEAT PUMP SCHEDULE CONDENSING UNIT NO. HP-1 UNIT EER 12.4 REFRIGERANT 410A NOMINAL COOLING CAPACITY (BTU/H) 144000 HEATING CAPACITY (BTU/H) 160000 AMBIENT TEMP (F) _ 95 UNIT MCA/MOCP 2 @ 21/30 each UNIT POWER SUPPLY (VOLTAGE/PHASE/HZ) 208/3/60 MANUFACTURER MITSUBISHI MODEL NO. PUHY-P144TSHMU-A NOTES: 1. PROVIDE FACTORY DISCONNECT. 2. PROVIDE FACTORY LOW AMBIENT CONTROLS. 3. PROVIDE ALL NECESSARY SAFETY DEVICES. 4. SIZE REF LINES PER MANUFACTURES RECOMMENDATIONS. 5. PROVIDE REFRIGERANT MANIFOLDS AND ALL OTHER COMPONENTS REQUIRED FOR VARIABLE REFRIGERANT FLOW SY`;TEM. VARIABLE REFRIOERNT FLOW DUCTLESS FAN COIL UNIT SCHEDULE UNIT DESIGNATION �i FCIJ-1 FCU-2 FCU-3 FCU-4 AREA SERVED KITCHEN 127 KITCHEN 127 KITCHEN 127 KITCHEN 126 UNIT TYPE Ceiling Cassette Ceiling Cassette Ceiling Cassette Ceiling Cassette REFRIGERAI', ` 41OA 41OA 41OA 41OA SUPPLY AIRF_OW (CFM, HIGHH SPEED) 1059 1059 1059 1059 EXTERNAL S '. (IN. WG.) s 01' 01" 01" 0" ENTERING Ai:-, DBANB (DEG, F.) 75/63 75/63 75/63 75/63 TOTAL COOL'JG CAPACITY (BTU/H) 36000 36000 36000 36000 REVERSE CY �'LE HEATING (BTU/H) 40000 40000 40000 40000 UNIT POWEP SUPPLY (VOLTAGE/PHASE/HZ) MCA/MOCP 208-230/1 208-230/1 208-230/1 208-230/1 1.1/15 1.1/15 1.1/15 1.1/15 MANUFACTURER MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MODEL NO. PLFY-P36NBMU-E PLFY-P36NBMU-E PLFY-P36NBMU-E PLFY-P36NBMU-E CONNECTED TO HEAT PUMP UNIT: HP-1 HP-1 HP-1 HP-1 NOTES: 1. PROVIDE FCU WITH SINGLE POINT POWER CONNECTION. COORDINATE WITH ELECTRICAL CONTRACTOR. 2. PROVIDE UNITS WITH DISCONNECT SWITCH, MOTOR STARTER, CONTROL. BOXWITH TRANSFORMER. 3. PROVIDE PROGRAMMABLE ELECTRONIC THERMOSTAT. 4. PROVIDE ME RV-8 FILTERS. AIR DISTRIBUTION DEVICE SCHEDULE TYPE DESCRIPTION NECK FACE SIZE MANUF. NOMINAL CFM RANGE 6" � 1 12x12 0-125 6"�) 2424 0-125 ALUMINUM, CONCENTRIC -CONE A CEILING DIFFUSER, MODEL TMS-AA 8110 24x24 TITUS 126-225 10,10 24x24 226-450 } J 12"0 2424 451-650 a 8" 0 18x18 0-225 :D HIGH -CAPACITY LOUVERED CEILING Al SUPPLY DIFFUSER, MODEL TDC-AA 10" 18x18 TITUS 226-450 12"0 18x18 451-650 12x6 12x6 0-200 ALUMINUM, DOUBLE -DEFLECTION, D/D1 20x6 20x6 TITUS 0-450 SUPPLY REGISTER MODEL 30OFS ALUMINUM, 00 SINGLE -DEFLECTION, 12x12 12x12 0-500 E SIDEWALL RETURN GRILLE, MODEL TITUS 48x24 48x24 0-5000 Q350ZFL X 12x12 12x12 0-500 LU 18x18 18x18 0-1200 z ALUMINUM EGGCRATE FILTERED Ir D B/C CEILING RETURN GRILLE, MODEL TITUS 2424 2424 0-1800 w 50FF 36x18 36x18 0-2400 ASHRAE 62.1-2007 VENTILATION AND AIR BALANCE CALCULATION PGA CLUBHOUSE @ THE RESERVE ROOM / ZONE ROOM NO AREA (SF) DEFAULT OCCUPANCY (QTY/1000 SF) CALCULATED OCCUPANCY (PEOPLE) I�p VENT. RATE (CFM / P) Vbzp (CFM) Ra VENT. RATE (CFM / SF) Vbza (CFM) VENTILATION REQUIREMENT Vbz=Vbzp+Vbz a (CFM) Ez ZONE AIR DISTRIBUTION EFFECTIVENESS Vbz CORRECTED OUTSIDE AIR REQUIREMENT (OF! VI EXHAUST RATE (CFM) _ RTU-1 150 1 150 RTU-2 300 1 300 RTU-3 - 425 1 _ 425 RTU-4 _ _ 750 1 750 RTU-5 _ - 500 _ 1 500 AHU #1 _ AHU #2 - 300 120_ 1 1 300 _ 120 _ RTU #1 1800 1 1800 _ RTU #2 870 1 870 _ RTU #3 870 1 870 EXISTING HOOD 6500 1 6500 8400 HOOD #1 2160 1 _ 2160 2700 HOOD #2 2700 1 2700 3375 -LOCKERS 650 LOCKERS 600 TOTAL 17445 1 17445 1 15725 TOTAL VENTILATION AIR REQUIREMENT 17445 TOTAL EXH. RATE PLUS 5% 16511 FINAL VENT. REQUIREMENT (Greater of Above 17445 TOTAL VENTILATION AIR NEEDED 17445 Date: 25-Mar-14 Gregory Engineering, Inc. Innovative design solutions for engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 THESE PL4NS AND ALL PRpPQSEC ARE SUBJECT TES A64Y CORRECWORK REQUiI EB �3Y FIELD IT►®NSPECTORS THAT MAYBE NECESSARY III ORCER TO COMPLY VV" ALL APPLICABLE COCES. PACKAGED ROOFTOP HEAT PUMP SCHEDULE DESIGNATION e RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU-6 AREA SERVED MEETING/ANTE ROOM," TOILETS/LOCKERS/GALLERY TOILETS/LOCKERS/GALLERY MEMBER DINING MEMBER BAR BAR (ALTERNATE) MANUFACTURER TRANS TRANE. TRANE TRANE TRANE TRANE MODEL NO. WSC036E3 WSC0361E3 WSC090E3 WSC120E3 WSC090E3 WSC090E3 NOMINAL TONS 3 3 7.5 10 7.5 7.5 SUPPLY AIR FLOW (CFM) 1075 1200 2700 3600 2800 2800 O/A AIRFLOW (CFM) 150 300 425 750 500 500 EXT. STATIC PRESSURE (in. wg) 0.6" 0.6" 0.6'" 0.6" 0.6" 0.6" EVAPORATOR FAN HP 1.00 1.00 1.00 3.75 1.00 1.00 COMPRESSOR QTY/TYPE 1 / SCROLL 1 / SCROLL 1 / SCROLL 2 / SCROLL 1 / SCROLL 1 / SCROLL UNIT VOLTAGE/PHASE 208/3 208/3 _ - 208/3 208/3 208/3 208/3 UNIT MCA/MOCP 39.5i45 39.5/45 85.2/100 98.8/100 85.2/100 85.2/100 ENTERING AIR TEMPERATURE (DB/WB) 80/67 80/67 80/67 80/67 80/67 80/67 AMBIENT TEMPERATURE (DB) 95 95 95 95 95 95 GROSS TOTAL COOLING AT ARI (BTU/H) 37,000 37,000 89,000 118,000 89,000 89,000 GROSS SENSIBLE COOLING (BTU/H) 26,600 26,600 64,000 85,000 64,000 64,000 REVERSE CYCLE HEATING (BTU/H) 37,000 37,000 86,000 111,000 86,000 86,000 ELECTRIC HEAT (KW) @ 230V 6 6 18 18 18 18 REFRIGERANT R-41DA R-410A, R-41OA R-4-IOA R-41OA _ R-41OA MINIMUM UNIT SEER/EER (AT A.R.I.) 13.0 13.0 11.1 11.2 11.1 11.1 MINIMUM UNIT HSPF/COP (ATA.R.i.) 8.0 8.0 3.4 3.6 3.4 3.4 UNIT WEIGHT, INCLUDING CURB (LBS.) 700 700 1000 1400 - 1000 1000 REMARKS 1,2,3,4,5,6,7 1,2,3,4,5,IS, 7 1,2,3,4,5,6,7 1,2,3,4,5,617 1,2,3,4,5,6,7 1,2,3,4,5,6,7 NOTES: - - 1. FURNISH 18" FACTORY ROOF CURB AND FLASHING. - 2. PROVIDE SINGLE -POINT POWER CONNECTION; COORD. WITH ELECTRICAL CONTRACTOR. 3. PROVIDE MOTORIZED OUTSIDE AIR DAMPER/INTAKE: HOOD ASSEMBLY WHERE O/A EXCEEDS 300 CFM; PROVIDE MANUAL O/A DAMPER WHEN O/A = 300 CFM OR LESS. 4. NON -FUSED DISCONNECT TO BE FURNISHED/INSTAL.LED BY ELECTRICAL. 5. 120V GFI SERVICE RECEPTACLE FURNISHED/INSTALLED BY ELECTRICAL. 6. FURNISH FULLY -PROGRAMMABLE ELECTRONIC THERMOSTAT WITH LOCKAHLE METAL COVER. 7. EACH UNIT SHALL BE MECHANICALLY FASTENED TO CURB PER FBC & FMC REQUIREMENT'>. m zl1 i z z o_ U w H I w Q 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. i PLANNING xARCI11TECTURF •LANDSCAPF 7645 GATE PARKWAY, 4201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.corn Lic. Nos.: AA26000586 LC26000508 o 4 AN 4�i Rlrgo �s DRAWN BY WMG _ CHECKED BY WMG DATE 3-26-2014 JOB NO, 13-40 SHEET NO. PRIMER PLUG CLEANOUT PLUG POND DRAIN PAN OUTLET CONNECTION PITCH DOWN TOWARD DRAIN COND. TRAP DETAIL M2.2 NOT TO SCALE CONSTRUCT GALVANIZED SHEET METAL HOOD. HOOD SEAMS SHALL BE SOLDERED. PROVIDE HOOD FOR PIPING EXITING ON OPPOSITE SIDES WHERE SHOWN ON ROOF PLAN. --- --- FILL VOID WITH EXPANDING FOAM ROOF DECK TWO PIECE PIPE CLAMP INSULATED REFRIGERANT PIPE 1-5/8", 16 GAUGE GALVANIZED CHANNELS BACK TO BACK. PITCH _ 2" PIPE SUPPORT COLUMN INSULATION S�_z 4"x4"x1 /4" THICK STEEL PLATE ANCHORED TO ROOF DECK . ANCHORS SHALL NOT PENETRATE THE ROOF DECK MORE THAN 3/4" DEEP. NOTES: 1 FLASH AROUND PIPING SUPPORT COLUMN. 2 PIPING SHALL BE SLOPED TOWARD THE CONDENSING UNITS. REFRIGERANT PIPING ROOF CAP DETAIL NOT TO SCALE CONDENSING UNIT 3/8"0 x 3" L.G. LAG SCREW WITH PREFAB GALVANIZED CAULK (TYP OF 4) EQUIPMENT CURB REFRIGERANT PIPING (PROVIDE ROOF SUPPORT) FLASHING ROOFING yLi .. __..._....... ......_ ........ _ ....._..... ..........._..._... .......... ................_ .. ............................. ....... ........................ : PT BLOCKING AS REQ'D- INSULATION ROOF —MOUNTED HEAT PUMP DETAIL NOT TO SCALE STRAP HANGARS HANGER STRA7::j S 60" MAX. UNLESS FOOT OF STRAP IS PLACED UNDER A BOTTOM DUCT REINFORCEMENT 1" MIN. SCREWS MAY BE OMITTED IF HANGAR LOOPS UNDER DUCT HANGAR WITH LOAD RATED FASTENE 24" DIA. MAX. CURE 6WIRE SECURE 36" DIA. MAX. BAND OF SAME SIZE AS HANGER STRAP 10" DIA. MAX. LOAD RATED FASTNERS TRAPEZE HANGARS SIZE BOLT(S) FOR LOAD DUCTWORK SUPPORT DETAIL. NOT TO SCALE HANGER STRAPS: 1 "x 22 GAUGE, FLEXIBLE DUCT: SUPPORTED FROM STRUCTURE ABOVE, INSULATED, MAXIMUM 6'-0" (3) SHEET METAL SCREWS BELOW. DO NOT SAG OR KINK WRAP INSULATION: OVER— ROUND SELF—SEALING DUCT EQUAL TO LAP 4 MINIMUM, STAPLE SPIROSAFE• WRAP WITH & TAPE FOR VAPOR SEAL ES SHOW ARE TIKSIDE FR EA ENSIO 2 DUCT INSULATION; SEAL INSULATION WITH 1 GLASS FABRIC/MASTIC J TAPE AND MASTIC OUTER JACKET (TYPICAL) SECURE INSULATION WITH MINIMUM RADIUS EQUAL TO STICK —PINS AT 18" O.C. / THE FLEX DUCT DIAMETER- / AND ADHESIVE ON BOTTOM, FOR DUCTS 24" AND LARGER CONICAL SPIN -IN FITTING WITH VOLUME DAMPER EQUAL TO CROWN PRODUCTS MODEL 3200—DS (SEE SPECS FOR OTHER OPTIONS) DUCT FABRICATION NOTES: MAXIMUM VERTICAL DUCT RUN WIRE SUPPORTS TO PREVENT SAGS AND KINKS IN FLEX BAND CLAMP AND THREE SHEET METAL SCREWS THROUGH HELIX OF FLEXIBLE DUCT LINER (TYPICAL) REFER TO AIR DEVICE SCHEDULE FOR TYPE. PRE —INSULATED DIFFUSER BACK. 1. SHEET METAL DUCTS SHALL BE FABRICATED & INSTALLED PER THE LATEST EDITION OF SMACNA DUCT CONSTRUCTION STANDARDS. 2. ALTERNATE INTERPRETATIONS OF SMACNA DUCT MATERIAL, HANGERS AND REINFORCEMENTS ARE SUBJECT TO ENGINEER APPROVAL, AND REQUIRE SEPARATE SUBMITTAL OF THE ALTERNATES. 3. FLEXIBLE DUCT CONNECTORS SHALL BE PROVIDED WHERE SHOWN ON THE PLAN. 4. SUPPLY AIR DROPS FROM ROOFTOP UNITS SHALL TRANSITION FROM THE UNIT OPENING SIZE TO SQUARE NECK ELBOWS, WITH SIZES AS SHOWN ON THE PLAN. IF TWO SUPPLY AIR DUCT RUNS ARE AT THE UNIT, THEN TWO SEPERATE DROPS & ELBOWS SHALL BE PROVIDED. 5. RETURN AIR DROPS FROM THE ROOFTOP UNITS SHALL BE FULL SIZE OF THE UNIT OPENING. 6. ELBOWS SHALL BE SQUARE NECK (SAME IN OUT DIMENSION) WITH 2" DOUBLE THICKNESS TURNING VANES. 7. OFFSETS SHALL NOT REDUCE THE FREE AREA, AND SHALL NOT EXCEED 30°. A RADIUS HEEL HEEL SHALL BE PROVIDED ON 30° OFFSETS. SMALLER OFFSETS SHALL BE MITERED AT BOTH THE HEEL & THROAT. 8. TRANSITIONS SHALL NOT EXCEED 1:3 RATIO (4" TRANSITION PER FOOT SINGLE SIDED TRANSITION, AND 8" PER FOOT DOUBLE SIDED TRANSITION). 9, INSULATION SHALL BE NFPA 90 APPROVED, WITH MINIMUM 4.2 R VALUE. WRAP INSULATION SHALL BE 2" THICK WITH ALUMINUM FOIL FACING. LINER SHALL BE 1" THICK, 1-1/2 PCF DENSITY. 10. RECTANGULAR BRANCH CONNECTIONS SHALL BE 45° ENTRY TYPE PER SMACNA FIGURE 2-6. 11. ROUND DUCT CONNECTIONS SHALL BE WITH "CROWN PRODUCTS COMPANY" 3200-DS FITTINGS, DAMPER AND HANDLE. SPRAY PAINT LOCATIONS OF HANDLES. 12. FLEXIBLE DUCT SHALL INCLUDE AN INNER POLYETHYLENE LINER, A SPRING HELIX, 1-1/4" BLANKET INSULATION (R-6.0), A FOIL OUTER VAPOR BARRIER, AND BE UL-181 APPROVED. 13. SEAL ALL SUPPLY, RETURN & OUTSIDE AIR DUCT JOINTS WITH DUCT SEALER; SEAL ALL INSULATION JOINTS WITH GLASS FABRIC AND MASTIC. CONCEALED DUCTWORK DETAIL NOT TO SCALE MECHANICAL SUBCONTRACTOR SHALL PROVIDE ITEMS NOTED BELOW ROOFTOP UNIT GASKET AND SILICONE SEALING —� PRESSURE —TREATED WOOD NAILER STRIP FACTORY CURB: NRCA CURB HT.=18" APPROVED, 18 GAGE, SQUARE WITHIN 1/8" ON DIAGONAL MEASUREMENT, WITH A MINIMUM OF 8" ABOVE TOP OF ROOF MECH UNIT BASE GASKET & SEALANT 2—#10 TEK SCREWS ® 24" PT 2x WOOD NAILER Gregory Engineering, Inc. Innovative des{gn solutions €or engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 GENERAL CONTRACTOR SHALL PROVIDE ITEMS NOTED BELOW SEE DETAIL A —A COUNTER FLASHING STRIP —1" RIGID INSULATION -- 3" CANT STRIP / ,—ROOF MEMBRANE 12 GA ANGLE W/ 1-8" LEGS 0'-6" LG 0 24" (2 MIN PER SIDE) W/ 2—#10 TEK SCREWS EACH LEG ROOFING & FLASHING, SEE ARCH ROOF MEMBRANE 1 /2" DIA. EXPANSION BOLT 24" O.C. DETAIL A —A THESE PLANS A, ND ALL PR al�� �u��cT TO ANY CI 1. MECHANICAL SUBCONTRACTOR SHALL FURNISH ROOF OPENING SIZES & R�Q SUB EC FIELD I6d� I LOCATIONS, FOR STRUCTURAL SUPPORT FRAMING BY GENERAL CONTRACTOR. fQUIRED RE iDY FIEL IN R 2. THIS CURB DETAIL WILL ALLOW THE UNIT TO SLOPE WITH THE SLOPE OF THE ROOF PITCH. THIS DETAIL CAN ONLY BE USED (A) IF THE CONDENSATE DRAIN COMPLY WITH ALL APPLIC PAN OUTLET IS ON THE LOW SIDE OF THE UNIT, OR (B) IF THE CONDENSATE DRAIN PAN IS NOT AFFECTED BY SLOPE. THIS DETAIL CAN NOT BE USED IF THE CONDENSATE DRAIN CONNECTION IS ON THE HIGH SIDE OF THE UNIT. 3. COORDINATE THIS DETAIL WITH ARCHITECTURAL APPLICATIONS FOR THE ROOF. ROOFTOP UNIT CURB DETAI!� NOT TO SCALE NON —FUSED DISCONNECT FURNISHED & INSTALLED OUTSIDE AIR INTAKE HOOD BY ELEC. CONTRACTOR - WITH WASHABLE FILTER 120V CONVENIENCE OUTLET �\ FURNISHED & INSTALLED \ BY ELEC. CONTRACTOR �LJ � 7 I� /I w A I SINGLE POINT ELECTRICAL -� — POWER ENTRY IN BOTTOM OF UNIT. CONDENSATE DRAIN; SEE DETAIL PLAN VIEW NOTE: DUCT SMOKE DECTECTORS SHALL BE WIRED TO SHUT DOWN UNIT UPON DETEC11ON OF SMOKE AND SHALL BE CONNECTED TO A REMOTE AUDIBLE/VISUAL ANNUNCIATOR PANEL LOCATED IN A READILY VISIBLE LOCATION; COORD. PANEL LOCATION W/ OWNERS REP — ROOF FURNISH 18" FACTORY DUCT SMOKE ROOF CURB ------- DETECTOR WHERE SUPPLY AIRFLOW EXCEEDS 2000 CFM RETURN AIR SUPPLY AIR SIDE VIEW ROOFTOP UNIT DETAIL NOT TO SCALE � m, I I i I II i I� I o C U) w w � L� w Q � I I zmmaim THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. a� c� aj '..� n • � A w � n • lei BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 ®Pr e " °� S T ^ �° c `zcfl 6( DRAWN BY WMG CHECKED BY WMG DATE 3-26-2014 JOB NO. 13-40 SHEET NO. 2,02 FAC 61 G15-32 FIRE PROTECTION CRITERIA 61 G15— 32.003 (1) OVERALL DESCRIPTION THE NEW CONSTRUCTION SHALL BE A 1-STORY, WOOD -FRAMED CLUBHOUSE BUILDING WITH A NEW WET PIPE FIRE SPRINKLER SYSTEM DESIGNED PER NFPA 13, 2007 EDITION. THE EXISTING FIRE SPRINKLER RISER IN THE EXISTING BUILDING WILL BE EXTENDED INTO THE ADDITION TO SERVE THE SPRINKLER SYSTEM. (2) ACCEPTANCE TESTING ACCEPTANCE TESTING SHALL BE PROVIDED PER NFPA-13, 2010 EDITION. (3) OCCUPANCY CLASSIFCATION EXCEPT AS NOTED BELOW, THE ENTIRE BUILDING SHALL HAVE A LIGHT HAZARD OCCUPANCY CLASSIFICATION. (4) PREPERATION OF DOCUME yL—TS THE SPRINKLER SYSTEM FOR THE BUILDING WILL BE A WET PIPE SYSTEM, DESIGNED PER NFPA 13, 2010 EDITION, FOR LIGHT HAZARD OCCUPANY. THE SYSTEM WILL INCLUDE USING LISTED SCHEDULE 10 AND 40 STEEL OR CPVC PIPING LOCATED ABOVE THE CEILING, WITH PIPE DROPS TO RECESSED PENDENT OR SIDEWALL SPRINKLERS COVERING AREAS BELOW THE CEILING. ANY EXPOSED PIPING WILL BE STEEL, SCHEDULE 40. SPRINKLERS WILL BE ORDINARY -TEMPERATURE, QUICK -RESPONSE TYPE. (5) STRUCTURAL SUPPORT STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS FOR THE FIRE PROTECTION SYSTEM INCLUDING LIVE AND DEAD LOADS HAVE BEEN COORDINATED WITH THE STRUCTURAL ENGINEER. STEEL SLEEVES WILL BE SET PRIOR TO CONCRETE PLACEMENT, TO PROVIDE FOR PENETRATIONS OF FIRE PROTECTION PIPING THROUGH THE FLOORS OR ROOF STRUCTURE. CORE DRILLING WILL BE ALLOWED FOR CMU WALL PENETRATIONS FOR FIRE PROTECTION PIPING AS MAY BE REQUIRED. ALL PENETRATIONS WILL BE PROPLERLY FIRE -CAULKED, AS REQUIRED. 61 G15-32.004 2(a) POINT OF SERVICE: POINT OF SERVICE IS AN EXISTING 6" FIRE SERVICE MAIN AND RISER. AN EXISTING 6" HYDRANT WILL SERVE THE BUILDING ADDITION. 2(b) GOVERNING STANDARDS:. SYSTEM DESIGN AND INSTALLATION SHALL COMPLY WITH 2O10 EDITION OF PFPA-13 AND THE 2010 EDITION OF I'IFPA-24 AS WELL AS THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDr FIRE PREVENTION CODE. 2(c) OCCUPANCY CLASSIFICAT OL U EXCEPT AS NOTED, BUILDING IS CLASSIFIED AS LIGHT HAZARD OCCUPANCY. 2(d) DESIGN APPROACH: SYSTEM SHALL BE A HYDRAULICALLY -CALCULATED, FULLY -AUTOMATIC, WET -PIPE SYSTEM INSTALLED THROUGHOUT THE ENTIRE ADDITION, EXCEPT PORTIONS OF SYSTEM PROTECTING ATTACHED CANOPIES SHALL BE PROTECTED FROM FREEZING BY ANY OF THE APPROVED METHODS OUTLINED IN NFPA-13, 2007 EDITION. THE ATTIC AND EXTERIOR PORCHES THAT ARE SUBJECT TO FREEZING SHALL BE PROTECTED BY A DRY -PIPE SYSTEM AS INDICATED IN NFPA-13, 2007 EDITION. EXCEPT FOR THE KITCHEN, MECHANICAL, JANITOR AND STORAGE ROOMS, THE FIRE SPRINKLER SYSTEM FOR THE ENTIRE BUILDING SHALL BE DESIGNED FOR LIGHT HAZARD OCCUPANCY WITH HYDRAULIC CALCULATIONS BASED ON AREA/DENSITY CRITERIA OF 0.10 GPM/SF OVER THE MOST HYDRAULICALLY DEMANDING 1500 SQUARE FEET; MAXIMUM COVERAGE AREA SHALL NOT EXCEED 225 SF PER SPRINKLER; MAXIMUM DISTANCE BETWEEN SPRINKLERS SHALL NOT EXCEED 15 FEET. FIRE SPRINKLER SYSTEM FOR THE KITCHEN, MECHANICAL, JANITOR AND STORAGE ROOMS SHALL BE DESIGNED FOR ORDINARY GROUP 1 HAZARD OCCUPANCY WITH HYDRAULIC CALCULATIONS BASED ON AREA/DENSITY CRITERIA OF 0.15 GPM/SF OVER THE MOST HYDRAULICALLY DEMANDING 1500 SQUARE FEET; MAXIMUM COVERAGE AREA SHALL NOT EXCEED 130 SF PER SPRINKLER; MAXIMUM DISTANCE BETWEEN SPRINKLERS SHALL NOT EXCEED 15 FEET. THE ATTIC SHALL BE CONSIDERED A LIGHT HAZARD OCCUPANCY AND SHALL HAVE A MINIMUM DESIGN DENSITY OF 0.10 GPM/SF OVER THE MOST HYDRAULICALLY DEMANDING 1500 SF; MAXIMUM COVERAGE AREA PER SPRINKLER SHALL NOT EXCEED 120 SF; MAXIMUM SPRINKLER SPACING PARALLEL TO THE ROOF SLOPE SHALL NOT EXCEED 15 FEET; MAXIMUM SPRINKLER SPACING PERPENDICULAR TO THE ROOF SLOPE SHALL NOT EXCEED 8 FEET; SPRINKLERS SHALL BE INTERMEDIATE TEMPERATURE ATTIC SPRINKLERS. EXTERIOR PORCHES UNDER ROOF SHALL BE CONSIDERED LIGHT HAZARD OCCUPANCY AND HAVE A MINIMUM DESIGN DENSITY OF 0.10 GPM/SF OVER THE MOST DEMANDING 1500 SF; MAXIMUM COVERAGE AREA PER SPRINKLER SHALL NOT EXCEED 225 SF; MAXIMUM SPRINKLER SPACING SHALL NOT EXCEED 15 FEET; SPRINKLERS SHALL BE ORDINARY TEMPERATURE, DRY SPRINKLERS; PROTECT EXPOSED PIPING WITH ANTI -FREEZE SOLUTION OR ALTERNATE METHOD OF FREEZE PROTECTION. 2(e) WATER SUPPLY CHARACTERISTICS: THE WATER SUPPLY SHALL [SI FROM AN EXISTING 6" FIRE MAIN. 2(f) FLOW TEST INFORMATION:. FLOW TEST WAS CONDUCTED ON 3/14/2014 BY BRIAN VIVIECA OF METRO FIRE NUMBER/DIAMETER OF PORTS FLOWED: 2/2.5" STATIC PRESSURE: 60 PSI RESIDUAL PRESSURE: 35 PSI PITOT PRESSURE: 28 PSI MEASURED FLOW RATE: 957 GPM CALCULATED FLOW AT 20 PSI: 1233 GPM HYDRANT LOCATION: SOUTHEAST PARKING LOT 2(g) VALVING AND ALARM RE UIREME:NTS: INSTALL FLOW SWITCH IN FIRE RISER AND PUT TAMPER SWITCH ON CONTROL VALVE IN RISER WITH LOCAL AUDIBLE ALARM AND CENTRAL STATION MONITORING - ISOLATION VALVES ON BACKFLOW PREVENTER OUTSIDE SHALL BE CHAINED AND LOCKED OPEN. 2(h) MIC RISK EVALUATION: THERE IS BELIEVED TO BE A MINIMAL RISK OF MIC IN THE WATER SUPPLY AT THIS LOCATION. — — 2(1) BACKFLOW PREVENTION DETAILS: AN EXISTING 6" DDCBFP SHALL SERVE THE BUILDING. 2(j) COMPONENT SPECIFICATI NS: ALL INSIDE AND UNDERGROUND PIPING, VALVES, SWITCHES, AND OTHER COMPONENTS TO BE UL AND FM LISTED MATERIALS FOR FIRE PROTECTION. ALL UNDERGROUND PIPING SHALL BE INSTALLED BY A STATE (FS635.521) CERTIFIED CONTRACTOR, WHO SHALL BE RESPONSIBLE FOR PIPING OUTSIDE OF THE BUILDING UPTO ONE FOOT ABOVE FINISHED FLOOR INSIDE THE BUILDING. HYDRANT Gregory n ineerin �...._.Y-.-_... - --.-........ - lnnovative design solutions For engineered building systems 4567 Deep River Place Jacksonville, FL 32224 (904) 714-5188 Cert. of Authorization # 28163 rHZSE PL4w ARE SUUJ� T IC pRoposEb REQUIRRK ky F] ! y CORREC-ric) 7- dgygE'C�� SP�CT�R��.�AT comp, y hYIN CAozR t® �iT�g ALL �p pLBCgQLE cc),) Es. FAC 161315-32 FIRE SPRINKLER CRITERIA [DLAN SCALE: 1 /16" = 1'-0" m I o C) w 0 w � w I Q 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING-ARCIHTECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 DRAWN BY WMG CHECKED BY WMG DATE 3-26-2014 JOB NO. 13-40 SHEET NO. FPI.*l LIGHTING FIXTURE SCHEDULE ---- ---- _-- TYPE MANUFACTURER CATALOG NUMBER LAMP VOLTS MTG. NOTES SIZE QUAN. A WILLIAMS 5OG-524-232-S-A12125-E132-UNV 32WT8 - 3000K _ 2 MT RECESSED 2x4 FLUOR. TROFFER - NOTE 3 B WILLIAMS 17-2-217-A-EB2-HNV 17W T8 - 30001K 2 MT CEILING 2 FT. FLUORESCENT WRAP C jWILLIAMS 75-4-LED*PH30/8 1,0-EDD*PH-120 26W LED - 30001K. N/A 120 jNOTE8 LED STRIP - NOTE 3 D1 INTENSE IML6L1309-C-SF 12W LED- 3000K N/A 120 RECESSED 6" DOWN LIGHT- NOTES 1,3 D2 INTENSE IML6L2309-C-SF 17W LED- 3000K N/A 120 RECESSED 6" DOWN LIGHT- NOTES 1,3 D3 INTENSE IML61_3309-C-SF 26W LED- 3000K- _ N/A 120 RECESSED 6" DOWN LIGHT- NOTES 1,3 D6 INTENSE IML6L13O9-C-SF-D10___ - 12W LED- 3000K N/A 120 RECESSED 6" DOWN LIGHT- NOTES 1,3 D7 INTENSE IML6L2309-C-SF-D10 17W LED- 30001K_ N/A 120 RECESSED 6" DOWNLIGHT- NOTES 1,3 D8 INTENSE IML6L3309-C-SF-D10 26W LED- 3000K N/A 120 RECESSED 6" DOWNLIGHT- NOTES 1,3 D9 INTENSE IML6L4309-C-SF-D10 _ 38W LED 3_000K N/A 120 RECESSED 6" DOWN LIGHT- NOTES 1,3 E BEGHELLI XMR-S1 _ 7W MR16 2 120 WALL BATTERY OPERATED EM. LIGHT F1 INTENSE IL-DRTR-AIC-L13O'iD10V-16 / RTRD300-C-SF 481W 4W LED - 3000K N/A 120 RECESSED 4" DOWN LIGHT- IC RATED F2 INTENSE 14-ICR49WW(LED) PAR20 LED - 3000K N/A 120 RECESSED 4" DOWN LIGHT - NOTE 1 WALL SCONCE - BAR AREA G VISUAL COMFORT CHD-1448BZ-CHS1-04NP _ 40W CANDELABRA 2 120 WALL H INTENSE 14/ ICR49WW (LEIS) 8W PAR20 LED 1 120 RECESSED 4" DOWN LIGHT- NOTE 4 K _ DAY-BRITE WI-N-24W-L-U-F1tWT-W F 24W 4100K LED _ N/A 120 WALL 10' A.F.G. LED WALLPACK L INTENSE SS6G21100308 16W LED- 3000K N�/A_ 120 RECESSED SHOWER LIGHT- NOTE 1 M WILLIAMS 50G-524-332-S-A12125-EB2-UNV A 32WT8 - 3000K 2 MT RECESSED 2x4 FLUOR. TROFFER N INTENSE ICRLS4650309C-SFW 1OW LED - 3000Kl� N/A 120 RECESSED 4" DOWN LIGHT RETROFIT 3 HEAD ADJUSTABLE DISPLAY -NOTES .1,3 0 INTENSE ICL-R-0131-1-2-309 3-D10-WW-60 57W LED - 3000Ks N/A 120 RECESSED P INTENSE ICL-R-OB1-L3-309 3-D10-WW-16 66W LED- 30001K N/A 120 RECESSED 3 HEAD ADJUSTABLE DISPLAY- NOTES 1,3 Q INTENSE ICL-R-0131-1-3-309 3-D10-WW-37 66V\\' LED- 3000K N/A 120 RECESSED 3 HEAD ADJUSTABLE DISPLAY- NOTES 1 R LITON LHLD2-04A-LRLD219 _ 4W LED- 3000K _ N/A 120 RECESSED 2" DOWN LIGHT- NOTE 1 S WILLIAMS 17-4-232-A-EB2-UNV 32WT8 - 3000K 2 120 CEILING -_ 4' FLUORESCENT WRAP T NOT USED U _ _ _ _ _ _ _ _ _ NOT USED V � NOT USED W IMPACT LIGHTING _ IL-TG--UB-WW-30()')IK-12ViF'ED _ 1.5W/LF NA 12 COVE LED COVE LIGHTING - NOTE 6 , X1 X2 BEGHELLI BEGHELLI FME-SA-LR-I-WVJ FF _ _- FME-SA-LR-2-WW FF+) LED _^- _ N/;e{ N/A �120 - 120- CEILING WALL EXIT SIGN - SINGLE FACE EXITSIGN - DOUBLE FACE LIGHTING FIXTURE SCHEDULE NOTES: 1. PROVIDE TENMAT BARRIER BOX OR EQUAL FOR INSULATION SEPARATION WHERE REQUIRED. 2. SEE ARCHITECTURAL CEILING PLAN FOR EXACT LOCATIONS OF LIGHT FIXTURES. 3. FIXTURE TYPES AE, CE, D1E, D2E, D3E, D6E, D7E, D8E, D9E, F1E, ME, OE, AND PE SHALL BE THE SAME AS TYPES A,C, D1, D2, D3, D6, D7, D8, D9, F1, M, 0, AND P RESPI CTIVELY EXCEPT THEY SHALL CONTAIN AN EMERGENCY BATTERY BALLASTS, BALLASTS SHALL PROVIDE 1400 LUMENS FOR LINEAR LAMPS AND 700 LUMENS FOR CF/LED LAMPS. 4. IN EXISTING CEILING CONDITIONS, USE EQUIV/.LENT REMODEL HOUSING (14R). 5. FIXTURE MOUNTING HEIGHTAS DIRECTED BY /�RCHITE:CT/INTERIOR DESIGNER. 6. PROVIDE AN IMPACT LIGHTING # IL-TRS-DIM- 00-12V-110TRANSFORMER FOR COVE LIGHTING. 7. AIM FOR BEST EFFECT. 8. FIXTURES SHALL BE INSTALLED ON TOP OF LOCKERS, FACING UP. 1111111 1, mill m ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. ® EXHAUST HOOD LIGHTS SUPPLIED WITH HOOD AND INSTALLED BY ELECTRICAL CONTRACTOR. ® REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. ® THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATIONS DIRECTLY UPON CONTRACTOR. ® SEPARATE GREEN GROUND CONDUCTOR SHALL BE ROUTED IN ALL CONDUITS WITH ALL PHASE CONDUCTORS. ® ALL MECHANICAL EQUIPMENT SHALL 13E COMPLETELY CONNECTED BY ELECTRICAL CONTRACTOR INCLUDING BOTH POWER AND CONTROL WIRING. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS. ® BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS FOR CLARITY ONLY, ELECTRICAL CONTRACTOR MAY GROUP SINGLE POLE BRANCH CIRCUITS IN MULTIPLE CIRCUITS HOME RUNS. (3 CIRCUITS MAX ® 120/208V 30, 2 CIRCUITS MAX ® 120/24OV. 30 & 10). A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER, RECEPTACLE, AND LIGHTING CONDUITS. (BALL EXTERIOR CONDUIT FOR ROOF MOUNTED EQUIPMENT AND WIRING SHALL BE MINIMIZED BY ROUTING IN CEILING SPACE. NO EXTERIOR CONDUIT WILL BE ACCEPTED. Chi ALL CONDUITS SHALL BE CONCEALED IN WALL SPACE, CEILING SPACE OR UNDER FLOOR, NO EXPOSED CONDUITS PERMITTED. ® COMPLETE SYSTEM SHALL BE GROUt0ED PER N.E.0 ARTICLE 250,. ® FINAL CONECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITH U.L. APPROVED LIQUIDTIGHT CONDUIT. PROVIDE WITH GROUND WIRE SIZED PER N.E.C. ARTICLE 250 (2008). 0 E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING 1-0 COMPLY WITH N.F.P.A. 96.7-3.1.3 FOR POWER SHUTOFF ON ALL ELECTRICAL EQUIPMENT UNDER OVEN HOOD. VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHING SYSTEM SUPPLIER. PROVIDE POWER IF REQUIRED BY LOCAL CODE. ® ALL BRANCH CIRCUIT WIRE SIZE SHALL BE MINIMUM #12 AWG COPPER. PULL EQUIPMENT GROUND IN ALL RACEWAYS, PER N.E.C. , ELECTRICAL CONTRACTOR SHALL PROVIDE PROPER NUMBER AND SIZE CONDUCTOR PER N.E.C.. ®ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH PANELBOARD A TYPED CIRCUIT DIRECTORY WITH PROTECTIVE PLASTIC SLEEVE. NFF Y 4) $ $2 $M $3 $D $F ®W CAGNMAAft 0 11*09 4 61, 1 RECESSED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION. UPPER CASE LETTER INDICATES FIXTURE TYPE, TYPICAL FOR ALL LIGHTING FIXTURES. RECESSED LIGHTING FIXTURE, SAME AS ABOVE EXCEPT WITH EMERGENCY - - BALLAST. FLUORESCENT LIGHTING FIXTURE - SURFACE OR PENDANT MOUNTED. STRIP FLUORESCENT LIGHTING FIXTURE. PL FLUORESCENT, LED, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - RECESSED. PL FLUORESCENT, LED, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - SAME AS ABOVE PL FLUORESCENT, H.I.D. OR INCANDESCENT LIGHTING FIXTURE - SURFACE OR WALL MOUNTED. PENDANT MOUNTED LIGHTING FIXTURE. PL FLUORESCENT, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - FLOOD LIGHT. PENDANT MOUNTED PADDLE FAN COMPLETE WITH PENDANT & CEILING MOUNTED CANOPY -MOUNT AS DIRECTED BY INTERIOR DESIGNER/ARCHITECT, U.N.O. EXIT LIGHT - PROVIDE ARROWS AS INDICATED, SHADING DENOTES FACE OPERATION. DO NOT SWITCH. EMERGENCY LIGHTING FIXTURE. DO NOT SWITCH. TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL12211 WITH NO. P'd COVERPLATE - 46" MOUNTING HEIGHT, U.N.O. TOGGLE SWITCH - TWO POLE -- QUIEF TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL12221 WITH NO. P11 COVERPLATE - 46" MOUNTING HEIGHT, U.N.O. TOGGLE SWITCH - SINGLE POLE, 20 AMP, 120/"777V, MOTOR RATED, GROUNDING TYPE, MOUNT AT EQUIPMENT HOUSING. TOGGLE SWITCH - THREE-WAY QUIET TYPE, 20 AMP, 120/277 VOLT, HUBBELL NO. HBL12231 WITH NO. P11 COVERPLATE, 46" MOUNTING HEIGHT, U.N.O. DIMMER SWITCH - LUTRON NOVA SERIES, 2000 WATTS, SELECT FOR LOAD/BALLAST/DRIVER TYPE. 46" MOUNTING HEIGHT, U.N.O. FAN SPEED CONTROL SWITCH - LUTRON NFS-'I2E, 12 AMPS. 46" MOUNTING HEIGHT, U.N.O. OCCUPANCY SENSOR WALL SWITCH - WATTSTOPPER #DW-100-1. 46" MOUNTING HEIGHT, U.N.O. CEILING MOUNTED LOW VOLTAGE MOTION SENSOR-WA1 iSTOPPER DT-305. PROVIDE POWER PACKS AS REQUIRED. WALL MOUNTED OCCUPANCY' SENSOR -WATTSTOPPFR DT-205. MOUNTED AT 10` A.F.F. PROVIDE POWER PACKS AS REQUIRED. DUPLEX RECEPTACLE - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P8 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O. DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 42" MOUNTING HEIGHT, U.N.O. DOUBLE DUPLEX RECEPTACLES - (2) TWO 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P82 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O. DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, 3 WIRE GROUNDING. HUBBELL NO. GFTR201 WITH NO. NPJ261 COVERPLATE, 46" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18 " A. F. F. SAME AS ABOVE EXCEPT FLOOR MOUNTED IN TOMBSTONE DOUBLE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, 3 WIRE GROUNDING. (2) HUBBELL NO. GFTR201 WITH NO. NPJ2621 COVERPLATE, fb 46" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18" A.F.F. ® SPECIAL PURPOSE RECEPTACLE COMPLETE WITH IOVERPLATE. SEE FLOOR PLAN FOR COMPLETE CONFIGURAT, ION. DATA/TELEPHONE OUTLET - " INCH SQUARE JUNCTION BOX WITH 1-GANG ® EXTENSION RING, BLANK COVERPLATE - 18" MOUNTING HEIGHT, U.N.O. PROVIDE 1" CONDUIT TO ACCESSIBLE CEILING SF'ACE. Q JUNCTION BOX SIZE PER NEC. Q EXISTING TELEPHONE/DATA OUTLET. TV OUTLET - 4 INCH SQUARE JUNCTION BOX WI I H 1-GANG LD EXTENSION RING AND BLANK COVER PLATE - 96" MOUNTING HEIGHT, U.N.O. INSTALL 1 " C. TO CEILING SPACE. 340 WP U.N.O. AFF AC C GG E.C. El ©• FAC P FAAP FLUSH MOUNTED FLOOR BOA; WITH (1) DUPLEX RECEPTACLE, (1) DATA PLATE, AND (1) AV PLATE. WIREMOLD TYPE EFB6S WITH EFB61 OCTBK COVER. INSTALL (1) 1Y4" CONDUIT WITH PULLSTRING FROM AV luvl�l LOCATION TO CEILING, (1) 1,IV4" CONDUIT WITH PUI LSTRING FROM TEL/DATA LOCATION TO CEILING, AND (1) Y4" CONDUIT WITH POWER CABLES FOR POWER. MOTOR, FAN, PUMP OR AIR CONDITIONING UNIT CONNECTION PER NEC. LIGHTING AND/OR POWER PANELBOARD, WIRING IN CONDUIT, RUN CONCEALED IN SLAB OR UNDERGROUND. WIRING IN CONDUIT, RUN CONCEALED ABOVE CEILING OR IN WALLS. HOMERUN TO PANELBOARD - NUMBER OF ARROWS DENOTES QUANTITY OF CIRCUITS. CROSSMARKS INDICATE QUANTITY OF NO. 12 CONDUCTORS. RUNS VOID OF CROSSMARKS ARE 1 /2 INCH CONDUIT, 3 NO. 12, U.N.O. DO NOT COMBINE HOMERUNS EXCEPT AS SPECIFICALLY INDICATED ON THE PLAN. DISCONNECT SWITCH, "3 60/40" DENOTES 3 POLE:, 60 AMP, 40 AMP FUSES. DENOTES WEATHERPROOF WHILE -IN -USE - MOUNT RECEPTACLE VERTICALLY AND PROVIDE TAYMAC 71202 COVERPLATE, FOR SWITCHES PROVIDE TAYMAC 40110 COVERPLATE. UNLESS NOTED OTHERWISE. ABOVE FINISHED FLOOR. DENOTES MOUNTED ABOVE COUNTER HEIGHT. DENOTES MOUNTED RECCESSED IN CEILING SOFFIT. GREEN GROUND CONDUCTOR. EMPTY CONDUIT WITH PULL WIRE/CORD. IN --GROUND COMPOSITE HAND HOLE WITH TRAFFIC RATED COVER. SIZE AS REQUIRED BY CODE CEILING MOUNTED J-BOX WITH BLANK COVER PLATE FOR CAMERA. INSTALL 3/4" CONDUIT WITH PULLSTRING TO ACCESSIBLE CEILING LOCATION. SEMI -FLUSH MOUNTED MANUAL FIRE ALARM PULL STATION, 46 INCH MOUNTING HEIGHT. SEMI -FLUSH MOUNTED FIRE ALARM AUDIO /VISUAL WARNING DEVICE, 80 INCH MOUNTING HEIGHT FROM FLOOR TO BOTTOM OF DEVICE. DUCT MOUNTED SMOKE DETECTOR, MOUN I ED IN A/C (DUCT. 'SEE MECHANICAL DRAWING FOR MOUNTING LOCATION AND QUANTITY. AIR CONDITIONING/HEAT PUMP SHUT -DOWN RELAY. CEILING MOUNTED SMOKE DETECTOR. CEILING MOUNTED HEAT DETECTOR. FIRE ALARM CONTROL PANEL FIRE ALARM ANNUCIATOR PANEL THESE PLANS AND ALL PROPCSED WORK ARE SUBJECT TO ANY COfaRECTIONS REQUIRED UY FIELD INSPECTORS THAT MAY BE NECESSARY 864 ORDER TO COMPLY WITH ALL APPLICABLE CODES. ®_ E I �S*t,0UF.LLC "4)F spa �Al 1, e V� {��7{('^ rn. .... �..... ficete y A p•q } SHA4,ER P E LICENSE# 818�, IYY 7r S, ATE • g• •• ...•••ti`yC. m � z 0 Q � N w 0 W C� 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. n� OLD/ ct Ct no, BASHA-In!i & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE •LANDS('-1PP: 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 73 1 -2699 Website: www:bash amlucas.coin Lic. Nos.: AA26000586 eau_ DRAWN BY MEM CHECKED BY JBS DATE 7 ()3-26-14 JOB NO. 13-40 SHEET NO. I 0 0 0 i i ! rit rit, i ! ,II II II II®..... ...... .... r ii T =Q I LJ L�)`` °0 E , ® it II II II II II II II -LJ LJ ®: I 7 F ....iO ,t 1�' ................................ ......... ® (z ® E�� �0 I ! ! IQ �5�1 I;€..m� m I r I II 1� I 1 1 1 n I 1.... ....... w,.- 1...... ....:.� � ,1 II II aIJ € I I I C.�j, ®'! 0I L J I! m I I I -11 I I U® .. ........... ........_ .........�.�®;...._._® �.._...! II 1 ! ry :..: LL o .....I I � J I r. 0 r 112 f' ...... ...... r� (3)L L J �IQ �.,� O Q o,0 IVK U II II (,o i to ....... - I Q t _.._ IOr 77I �j 9 ® 9 9 II II '. ... _ 7 x I $ P (o) ........ II ' II c f.... ...... . L J 9 LJ LJj 0 Co) i a x /` , � ! (0) O / m �I jj Q E 3 C-r_j I V I C nG:3 u u I ,-_} i U U U 3 f f U �1 ®(p) ' 3 nQ Gi- (o) I U C(0) (o)� .......::.:.....: _4 v.W_ 3 I R r r =0G r =09 r 0 0 0 0 0 6 0 0 I................. _... ---- F --- Q rr— L=�=rjj ­, ­113 00 Q 1) 00 (z 00 a 00 r € € rr 1 ® 46, �,€itOQ p t QO ° (j,...... rr i0 1500 1500 g < ........... II it II II , IL 47( 0 0 rr �0 rr =0 0 0 II II II II O ....... :..:. E[ '_ 9 C�J.Z�JZrJZ�JZ rJ� � 9 I L J L � o 0 0 € ® (j I J4550 Q 0 r, ae NiO Qi 4eJ ® r� L J �O� OJ �O O `O p :: rt €._ ..�....� �7 ............ ELECTRICAL DEMO PLAN —LIGHTING SCALE: 1 /8"= 1'-0" NQTES: , ® REFERENCE NOTE ON DRAWING 1. EXISTING LIGHTING FIXTURES, CIRCUITING AND CONTROLSTOREMAINDEMOLITION NOTES: 2. EXISTING LIGHTING FIXTURES TO BE REMOVED. 1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING PUILDINGS WITHOUT PRIOR SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. 3. EXISTING DEVICE TO BE REMOVED. 2• THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE. ITEMS IN 4. EXISTING LIGHTING FIXTURE TO BE REPLACED. ASSOCIATION 'WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE 5. EXISTING SWITCHING TO BE REPLACED, CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 6. MAINTAIN CIRCUITS TO ALL EXISTING RTU'S, 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO AHU'S, AND CONDENSERS. EXISTING SYSTEMS AND SHALL UPON COMPLETION DELIVER "AS —BUILT" DRAWINGS TO ^I"HE OWNIER INDICATING ANY SUCH CHANGES. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL FXPOSED SECTIONS OF THIS DRAWING IS AN INSTRUMENT OF SE] AND THE PROPERTY OF RASHAM DESIGN AND SHALL REMAIN THEIR PROPERTY. TI OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARE PUBLICATION THEREOF IS EXPRESSLY IN SUCH USE. 4� ct QJ � ct O • s • CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS BASHAT SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING ,. LUCA CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT DESIGN GROUP Il THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALT_ REMOVE PLANNING -ARCHITECTURE -LANDS WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW F 1 z WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES ��% 7645 GATE PARKWAY, # OR FIXTURES. JACKSONVILLE, FLORIDA 3 (904) 731-2323 FAX (904) 731- 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED Website: wwxN*bash amlucas.com SYSTEMS MEET CURRENT CODES AND 'SPECIFICATIONS. REMOVE ALL UNUSED SURFACE' MOUNTED Lic. Nos.: AA26000586 CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON 'THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. i L 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 1"LAi�S AND ALL PROPOSED WOR! �ac�� SUBJECT YD ANY C®RREC?10AIS 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT lLQUIRED LAY FIEL3 INSPECTORS THAT INTERFERE WITH RENOVATIONS SHALL REMAIN. MAY BE NECESSARY IN ®RDER T® 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF c0'0PLY WITH ALL APPUCA13LE CO®E$,, EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT. DRAWN BY M F_,M CHECKED BY _ JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E2,0 I ....---....-- I ............ \�" : � 1 E I � p� p () ........... .............. .............. -- - -r° ..L—— W—tt — tt tt tt tttt--- —ffJ E I 1 pp — W 6 . ! 0- I IL EXISTING l EXISTING ATT KWHM TERMINAL :..... !BOX11 lli ®EXISTING PL EX !I0PI TR NSFO ER j PANE =L DPA T I � I �LICI p _._ L ! �................. ...._........ ��.......... m...�wl C> 77 ..., y ; ...... -- o uG`P l i 1 IL r......... r 0 EXISTING N® ® 7 PANELS Kee & Z —© wr L�J 4 01 �p LFJ EXISTIN R PANED is ......... ........ qq � Al> � 1 ff / E L J P : •. ® yf N E; ? pry• LFJ -. Wp© ! ®9 96" I{ ®u '(z) s _.. .............. .........�,. ...,.-....... .-..._..,._.. .........._._..�......._._......................._...-...._..........._..,,.,�.....,..._.m..._._,�,..,. s� ..... �.m m-. . .. ....... .. WP . (I® 0 Ca F� 01 96: I —..,'. �I 0 01 EXISTING FAAP o € � FOW4111 IN �\ '• 1 AND SYSTEMS SCALE: 1 /8"= 1'—O" NOTES: ® REFERENCE NOTE ON DRAWING r I f� t f ............ } T^ EXISTINGp PANE, FACP EXISTINq TELE. BOARE11 ®� EXISTING Q SECURITY"PANEL 9 ff® < I EXISTIN SOUND SYSTEM (ffl0 ;IT? V ffp ♦ � I! :.� o E ( S�)t� _ __.. T.._..v....... mmm ...... M. - i37..,,,n,.,<�:....... > EF•,^-�•-., �i�-•�a:..............3•,n.......-..4ih�-m-.-mf7........ J`r-....,,..,,.wp ii:::::::: ,gyp / ..E ..... ...... ....... o .. .... ....a 1. EXISTING DEVICE TO BE REMOVED. DEMOLITION NOTES: Se�RVER R ®EXISTING PANELS EA & B�B i i'llp RA 2. EXISTING DEVICE TO REMAIN. 1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WI rHOUT PRIOR SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. 3. EXISTING DEVICE TO BE REPLACED. 2. THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN 4. EXISTING DEVICE TO BE RELOCATED ASSOCIATION WITH THE WORK. ALL SALVAGEABLE I7FEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE 5. EXISTING PANEL TO REMAIN. CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 6. EXISTING PANEL TO BE REPLACED. 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS —BUILT" DRAWINGS TO THE OWNER, 7. EXISTING TRANSFORMER TO BE REPLACED BY INDICATING ANY SUCH CHANGES. FPL IF REQUIRED DUE TO BUILDING LOAD. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE- PULLED OUT AND ALL EXPOSED SECTIONS OF' CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL_ BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED Al' THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE: REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES OR FIXTURES. 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS MEET CURRENT CODES AND SPECIFICATIONS. REMOVE ALL UNUSED SURFACE MOUNTED CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL._ BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THA`f HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSART' REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT. THESE PLANS 41VO ALL PR® ARE SUr3jECT TO A14Y CPOSED WORK REQUIREL),gY FIELD L6gSPF.CT ECnOMS MAY 8E IVECESSa�RY9IV OR�gq ills ® T COMPLY WITH ALL APptLCQQtt: CODES. + SHAFFER a �ANfIN�j RINO 0 OUP.LLC z s eroa. s5'.re sot N e ` • yid L www haHeregcan I 80� }E<2���1///J [9N 2353623 , • ,.�....,...... ....... I�. ....-----3u. 3........ i�Aeof #. 28265 .B_.%.,_..---.AFFE _, E. U N 58168 - -� ` No 5 81--g Cc z � • � STATE` THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED PAID PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. C:4^ ct Q ct)s, c4 U r� ' r r BASHAM RT LUCAN" DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 ,JOB NO. 13-40 SHEET NO. H I I 37 rP1A-19 iP1A-23� iP1A-25J i i P1A-21J iP1A-29JI i P 1 A-27,9i LP1A-17J H n M M M Am M I E M M M E l�`�`•' jME P °3 A P1A M A ( '�, R: C .................. ___ ........... ...................... . $0 T � X1 39 N N 0 900 (00 00 xi € o -I N N a00 o� M DAN IDb�D6E_ X1 �T f; N L X1 D' p D3 O D3 - H H H H = P3B— D6 D6 D6 Q®D6 D6 D6 D6 D8 D8 $ob O O O O O O O OD8 O O __��CONNECT X2 CIRCUIT D9E D9 D9E D9 D9 D9 D9 O O O � D8 (ME D3E ,__ D3 1"'1 A, NL O14 ....................... � a; D3E —12 D3E , NL P3; . P38' 12 I .w I m_......... : .......�_...._ . m D8 D8 8E ` M D2E j.....1....W� O O ! P3 a `�-10 P3B-10 ....... .'...1E WE TING r NL D8 ® D8 € E O O C.. D1 IL D8 D8 D8 ...... TY^ 0 D1E E P313- P3B 13 OD8 OD8 O.. ®OD7 OD7 D7 D8D8 �...... ....... . PA IRON O X1 �OD7 N N G 00o o00 E X1 / / O D6 ® yy 00 D6E F1 r' / F1 p O p F1 O DF1 6 O O F1 � p6 F I O O F1 � O F10 O �. ;71 O D6 F1 O F1 F1 O p OF1 G F1 F1 D6 D6E O D6 OD6 D6p D D7E _D7 D7 P36_ 25 I6ID7 o X1 D6 O D6E 3 D6 G I D6 _ I 6E D E i D6 D6 D6 D8 D8 8 i O P3B-29 � D3 D3E D3-- D3 D3E I SEE: DWG —�' E3.2 FOR —I.E..i = CONTINUATION ;. OF CIRCUITS J I3 C,3 ( F2 O C>3� s o ---0 NL k?38-8 �� r ............................... » D1pr r�el�78 O i� M D 1 E D"1 a . ....... t ALL 6 ;. P3B-6f l ocQ Z�� rl.-4,- �DlE 12 _D7E D7E COVE LI HTS i TYPE ,W TYP. 3B-6 D7E 6 u SEE DWG E3.2 FOR D7 D7 D7 CONTINUATION �O O OF CIRCUITS s i D7 D7 D7E D7i O O PARTIAL ELECTRIC/AL LIGHTING PLA[\J SCALE: 1 /8"= V-0" PLAN NOTES: ® REFERENCE NOTE ON DRAWING 1. PROVIDE ADDITIONAL WIRES FOR 0-10V DIMMING. 2. CONNECT EXIT SIGNS, NIGHT LIGHTS, AND EMERGENCY BALLASTS AHEAD OF ANY SWITCHING. 3. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 4. ROUTE THROUGH LIGHTING CONTACTOR. 5. PROVIDE AS PART OF GUEST PAVILLION ALTERNATE. 6. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER PACKS PRIOR TO SWITCHES. 7. CONNECT TO EXISTING ROOM LIGHTING CIRCUIT WITH (3)#12, 1 /2" C. DO NOT EXCEED 1900 WATTS ON CIRCUIT. 8. CONNECT TO COOLER/FREEZER LIGHTING. 9. EXISTING LIGHT FIXTURE TO BE REPLACED. CONNECT TO EXISTING CIRCUIT.. 10. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS. 11. INSTALL NEW LED RETROFIT IN EXISTING FIXTURE 12. FAN TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 13. RELOCATE AND REPLACE EXISTING LIGHTING CONTROLS WITH NEW. FIELD VERIFY REQUIREMENTS. THESE PLANS AND ALL PROPOSE® ARE Su�JECr r® WORK ConliE REQUIRE') 2Y FIEL® NSPECr®��S i AY BE Cft ESSARY w ORDER Td T COMPLY WITH ALL APpUCABLE CODES. a Billion THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. cts� V CA `-� O s A F-� I� 1 BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 1 3-40 SHEET NO. m PARTIAL ELECTRICAL LIvHTING PLAN SCALE: 1 /8"= 1'—O" PLAN NOTES: ® REFERENCE NOTE ON DRAWING 1. PROVIDE ADDITIONAL WIRES FOR 0-10V DIMMING. 2. CONNECT EXIT SIGNS, NIGHT LIGHTS AND EMERGENCY BALLASTS AHEAD OF ANY SWITCHING. 3. CONNECT TO EXISTING AREA LIGHTING CIRCUIT WITH (3)#12, 1/2" C. DO NOT EXCEED 1900 WATTS ON CIRCUIT. 4. ROUTE THROUGH LIGHTING CONTACTOR. 5. REPLACE EXISTING LIGHT FIXTURE. 6. EXISTING LIGHTING TO REMAIN. 7. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 8. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER PACKS PRIOR TO SWITCHES. 9. INSTALL FIXTURE AT SOFFIT. SEE ARCHITECTURAL ELEVATIONS/SECTIONS. THESE PLANS ARID ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED 2Y FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. .. SHAFFER- ��`��� E N„ry,r:IL1 tu ITIIa/p OP, L L C ackso F spa t �"� ,PH 19jM1�(j6j1�. 904 y4�� �, •Certificl�q� imp-�816 �� 4 FFER E. LIC J B s ;m, er .,p ; = ST V' % THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SWILL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. ^V1 • U � 4� • E i a w w w w BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www-bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E3 • PARTIAL ELECTRICAL POWER AND SYSTEMS PLAN SCALE: 1/8"= 1'-0" NOTES: ® REFERENCE NOTE ON DRAWING 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED UNDER FLOOR. 2. EXISTING DEVICE TO REMAIN. 3. REPLACE EXISTING RECEPTACLE AND COVER PLATE. CONNECT TO EXISTING CIRCUIT. 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH (3)#12, 1/2" C. DO NOT EXCEED 8 RECEPTACLES PER CIRCUIT. 5. CUT AND PATCH EXISTING FLOOR TO INSTALL FLOOR BOX AND ASSOCIATED CONDUIT. THESE AMIS AND ALL PROPOSED WORK ARE SU JECT TO ANY CORRECTIONS flEQUIRED AN MELD INSPECTORS THAT NAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODE, AC I,yf1EAft i�`R �,, L L C j 1Za5i�i•lby $Ntl ,2 '. 1 JJa�eo e f paz aa.5io.s,� ; % ••PHie�yztssjn c%Aypa�4+,9- y, � Ce -fi 91e mmm�aizeno�; 8l6S�`' � I AFFER, . AQ NSE 5&1 i , s • `cy -Q'i41, �a .., )� a • Ll 1 0 .••' •. !!............................... I T,...�i m Z 0 o_ iz .� � c w 0 w Q O z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. V 1 c rFTi1 ctn U � • w • �1 • A I t� i • IW BASHAM & L U C Akr'S' DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:basbamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY .IBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E4,6 - 1 ............................................................................................................................................ `i S moll ■N■ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL RZMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. hi € fEct w � ® Yid I } } t ct cr HANDHOLE FOR FIBER/T SEE TEL/DAT/TV SINGLE NE\ DIAGRAM. ►—� 1 PARTIAL ELECTRICAL POWER AND SYSTEMS PLAN SCALE: 1 /8"= l'—O" NOTES: (9) REFERENCE NOTE ON DRAWING 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED UNDER FLOOR. 2. EXISTING DEVICE TO REMAIN. 3. REPLACE EXISTING RECEPTACLE AND COVER PLATE. CONNECT TO EXISTING CIRCUIT. 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH (3)#12, 1 /2" C. DO NOT EXCEED 8 RECEPTACLES PER CIRCUIT. 5. FEED COUNTER UNDER FLOOR. CUT AND PATCH EXISTING SLAB AS REQUIRED. 6. CUT AND PATCH EXISTING FLOOR TO INSTALL FLOOR BOX AND ASSOCIATED CONDUIT. 7, ELECTRICAL TO SERVICE STATION TO BE ROUTED UNDER FLOOR. 8„ PROVIDE (5) RECEPTACLES AND TV OUTLET LOCATIONS AT HEIGHTS AS INDICATED ON INTERIOR DESIGN ELEVATIONS. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED UY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ER I_UP.LLC gip:' ......- ........................... . .: N..°.a`_..._.............. �i • w BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY 3BS DATE 03-26-14 JOB NO. I3-40 SHEET NO. E402 ENLARGED KITCHE105 POWER AND SYSTEMS PLAN SCALE: 1 /4"= l'—O" QUIREMENTS AND MOUNTING HEIGHTS WITH FINAL KITCHEN EQUIPMENT SELECTIONS. 2. CIRCUITS FOR EQUIPMENT UNDER HOOD ARE PROVIDED WITH SHUNT TRIP BREAKERS. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM SO THAT ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL CUT POWER TO EQUIPMENT UNDER HOOD. 3. ROUTE CONTROL POWER THROUGH HOOD CONTROLS AND CONNECT TO GAS SOLENOID VALVE AND SHUNT TRIP AT PANEL OF EQUIPMENT UNDER HOOD, ACTIVATION OF ANSUL FIRE SYSTEM SHALL SHUT OFF THE GAS SOLENOID AND POWER TO EQUIPMENT UNDER THE HOOD AS WELL AS ACTIVATE FIRE ALARM. 4. CONNECTED TO DOOR HEATER AND LIGHTS. E ................ €.... ............ .... ............ j .... ...... ..... ..! i ........ € € i - i ---- ---- ......- i PE E._.. ...... .....I ............ ..... } '— � f i I - i - T........... - ._ ........... ENLARGED KITCHEN (127-Z POWER AND SYSTEMS PLAN SCALE: 1/4"= 1'-0" THESE PLAIDS AND ALL PROPOSED WORK APE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. I E 010 e �i N,�,ER igR0U1,LLC i �� a ' en� ;029 Com � 1 •C 9 �A�-/16j1` F �}i2 '623 i I •••.....�C R.. ....... .............. �ar1FLUP'i BRYAN SH FFER, P.E. LICENK V8T IOU r i `�•'' '/0NAL THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBUCATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. v V • ''� ® hrd ct Cr C4Z; V � a PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. OFF ICF 1'J, RY ROOM 0 � —2 G3 A L 1- v9EN'S 011 ET P3D-28 : v� t V ...E PI3043 1 EF AN'll"I ROOM r / / RE TAOImo,ANT HALL ER; I" N S I... A / I IP31D—1 PATRON I..ERRACE PRIVA-'fE DININ T2 PRIVA : I DIN1N E_, ei,s i "'�... i i f 4AINELS P3A, B, P3C 4 & P3D I...O B B Y �.��f tv!ERrl " D E .; . 1139 fr ...... 1, f . .............. ...... ..... ..................... ..................................... .............. 31LE f _.. '~ E L_ m� 11 „' I S` .fit �t��,! D-28 a 0 K T� M B ; v _. C 33 ,SSE S.-IBtJ H AL! EI.EC.' 12fl 3D-25 h 3100 10_� 0 i•"I E AD PRO AS I S . �0 ....; EF 3C-8=t Wi W.. 18,22 ` s CL € € 1 V P3C-8 P i M I ' /E I _ = _ ........ ... d, ` ,...._.._._...__._...�.... _ __.. .............._ ..... .... ...... t _ ................... _- --""- OVERALL & MECHANICAL E _ POWER PLAN m'fIL..rfl SCALE: 1/8"= 1'-0" SITE PLAN NOTES 1 H ® REFERENCE NOTE ON DRAWING E IN —GROUND 1. SEE POWER RISER DIAGRAM AND PANEL SCHEDULES FOR HANDHOLE WIRE AND CONDUIT REQUIREMENTS. 2. ALTERNATE FEEDER ROUTING. PROVIDE ALTERNATE PRICE. 3. BASE BID FEEDER ROUTING. 4. INCLUDE AS PART OF ALTERNATE PAVILLION #157 PLAN. 5. INSTALL WP J—BOX AND (2) 2" CONDUITS WITH PULLSTRING TO ROOM 139. P3C-2 f�WP, P3C-4 14 FCU-1 P3D-2 FCU-2 P3D-6 3 124 €€ U-3 D-10 i —PANEL P4A —PANEL I'4B MB`'R r Cry 1L-1 5 i F LF THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER T® COMPLY WITH ALL APPLICABLE CODES. ' g SHAFFER EN0R001,1LC (40�121, N_d, h 1 I s flE an ... .... �- '.. AFFEk� c LIC.5 ;N� 581 g • j,��J'/'C� 46 • j1I 10 , �i� • C•.O R l` S1� fix, 0 .. mill i THIS DRAWING IS AN INSTRUMENT OF SERVk; AND THE PROPERTY OF BASHAM DESIGN GRC AND SHALL REMAIN THEIR PROPERTY. THE 1 OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED A PUBLICATION THEREOF IS EXPRESSLY LIMITED SUCH USE. III n� 2 Q V/ ctct 1� <; U 4� U v� c.z; V1) con r� v r—� -7 • BASHATV & LUCAlk DESIGN GROUP, IN( PLANNING -ARCHITECTURE •LANDSCAI 7645 GATE PARKWAY, #2( JACKSONVILLE, FLORIDA 322' (904) 731-2323 FAX (904) 731-26- Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 0"-26-14 JOB NO. 1 �-40 SHEET NO. It UTILITY TRANSFORMER EXISTING BUILDING PTU-1 3 200 � 0 KWHM PANEL o DOA 1000A MCE3 208/120' 0 #3/0 IN 1 "C. TO BLDG. STEEL, EXISTING SWBD KWHM M D P O 2000A MCB 208/120V NEMA 3R EXISTING UTILITY TRANSFORMER® I I I ED #3/0 IN 1 "C. TO METAL WATER PIPE, EXISTING SERVICE GROUND AND BUILDING FOUNDATION REINFORCIN BAR NO LESS THAN 20 FEET LONG, 1/2 INCH MINIMUM DIAMETER. 3/4" x 16' COPPER CLAD GROUND ROD RTU-2 200 RTU-3 100 ACLU-1 60 ACCU-2 60 ��_ 3 0 3 0 I—� 3 0 �� 3 0 % TO BE REMOVED PANEL 1 200A M.L.O. 208/120V EXISTING POWER RISER DIAGRAM NOT TO SCALE EXISTING POWER RISER DIAGRAM NOTES: ® REFERENCE NOTE ON DRAWING 1. REMOVE I XISTING GROUND —NEUTRAL BOND. RTU-1 200 RTU-2. 200 RTU-3 100 ACCU-1 60 ACCU-2 60 I ----I 3 0 r---I � 0 r--7 3 0 r--7 3 0 )--7 3 0 1 1 1 J � 1 -11 11 L- J L_ L J L- J �--0 ------------ ----------------- EXISTING J ) �BUI DING III �1111 IIII� �SII ICI � 111��1 !II!I © ( PANEL I I PANEL I 'P1A' I i i I 'P1 B' I L.L I_ (— _ I I(FORMERLY� I I I(FORMERLYI 'At) PANEL DPA 1000A MCB 208/120V NEMA 3R I I 11 200A L M.L.O. J 208/120V --T---j I KA) II I 200A L M.L.O. J I 208/120V -- T— PANEL 'Pic" �(FO�RME=RLY1 KB) II � I 225A M.L.O. L J I L 208/120V T ' it 111111 'BB' I 200A M.L.O. 208/120V li I PANEL 'P2A' I(FORMERLYI BA) I � 200A I Tc L M.L.O. J 208/120V C0 T AHU-1 3 30 1 1 ' 12 15KW HEAT 3 60 � 60 GUTTER 15KW AHU-1 3 3O HEAT 3 60 r-� 12 F- 60 L_ J� T T +__0 +__0 L ---1 L---1 --- PANE L I 'P2B' I(FORMERLYI 'BB') 200A LM. L.O. J 208/120V AHU-2/ H EAT -3 60 (---i ' 35 AHU-2/ H EAT 3 6 () F - -I 30 L_TJ GUTTER — — — — — — — — i I I I..._W �- __ __ .— __.__------ ---- _------- I — — — — — —I- ----------------------------------------) ------ ------------------------------------------------------- - — — - EXISTING -- NEW NEW POWER RISER DIAGRAM NOT TO SCALE POWER RISER DIAGRAM NOTES: ® REFERENCE NOTE ON DRAWING 1. EXISTING WIRE AND CONDUIT TO REMAIN. 2, SEE PANEL SCHEDULE FOR WIRE AND CONDUCT SIZES. 3 6 SETS: (4)#400, 3" C. I D PHOT (TYP.)OCELL AT ROOF ,1® CHEF'S PANEL PANEL PANEL PANEL PANEL PANEL PANEL 'P3A' 'P3B' 'P3C' 'P3D' 'P4A' 'P4B' (BY 1 1 1 I 1 I OTHERS) I 225A 225A 225A Tc. 400A 225A 225A 125A M.L.O. M.L.O. M.L.O. M.L.O. M.L.Cl. M.L.O. M.L.O. 208/120V 208/120V 208/120V CONT 208/120V 208/120V 208/120V 208/120V (;ANT CTOR/TIME CLOCK (,1YP.S THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED UY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. 4. CONTRACTOR SHALL COORDINATE WITH FPL FOR UPGRADE OF ELECTRICAL SERVICE (AND TRANSFORMER IF REQUIRED) PRIOR TO BID. ALL FPL REQUIREMENTS SHALL BE INCLUDED IN THE ELECTRICAL DESIGN AS PART OF THE BID. 5. CON ;7 SHUNT TRIP BREAKERS TO HOOD CONTROL SYSTEM WITH (3) #12, SHAFFER ` t) ENCINEEiINR C"',,2 LLC ��t e 9 � na3s36z3 r°I% 5 ........ J. B pN6 58 O ••.A,x' OR .......... r m v� Z 0 o � La a W � a W a 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. c ct � V/ l • w � V1 BASHAM & LUCAS DESIGN GROUP, INC, PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.coln Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. FOR EMT, CONNECTORS SHALL BE COMPRESSION TYPE, WITH INSULATED THROAT 4" SQUARE - DEVICE BOX BUSHING NYLON BUSHING LAY -IN CEILING (T'P) 1 "E.C. WITH 1 "E.C. WITH PULLSTRING PULLSTRING TELEPHONE BOX DEVICE COVER WITH MAKE CIRCUIT JOINT WITH f30ARD RAISED RING OF PROPER TWIST -ON CONNECTOR, DEPTH AND TYPE FOR WALL AND CONNECT TO DEVICE TV TYPICAL CONSTRUCTION. RING TO I I WITH SINGLE LEADS. OUTLET GROUND BUS FINISH FLUSH WITH WALL ® -1#12 AWG GREEN INSULATED -- I JUMPER TO BOX BONDING #6G, 3/4" C. TO PANEL GROUND-�~ -- SCREW m •1 #12 AWG GREEN INSULATED m m.m ..................... �.............. ........... ........................................... ....... ............... L - JUMPER TO DEVICE GROUNDING II SCREW DEVICE TRIM PLA NOT TO SCALE TYPICAL DUPLEX RECEPTACLE INSTALLATION BRANCH CIRCUIT CONDUIT JUNCTION BOX ATTACHED TO STRUCTURE 6 I i' MAX. LENGTH OF FLEXIBLE CONDUIT TO ALLOW FOP RELOCATION. INCLUDE GROUND WIRE. MAXIMUM OF i HREE (3) FLEX. RUNS PER JUNCTION BOX. LAY -IN TYPE FLUORESCENT TPOFFER SEE LIGHTING FIXTURE SCHEDULE `- FASTEN TO CEILING MEMBER BY BOLTS, SCREWS OR RIVETS AT 2 LOCATIONS OF EACH OF THE TWO LONG SIDES. TYPE "G" INVERTED "I" CEILING GRID. SECURE FIXTURE TO GRID WITH APPROVED METHOD, FOUR PER FIXTURE. TYPICAL LAY -IN FIXTURE INSTALLATION - DETAIL �---�? •GROUND II' ANY' LINE mL ONEUTRAL VOLTAGE *UNE •LOAD OCCUPANCY SENSOR USING TERMINALS EMERGENCY LOCAL LIGHT OfF SWITCH NORMAL LIGHT U = W= C? 00 Z D LL J W IIPOWER _E PACK Z 4VIV IRVL vul ru CTRL OUT MAN SW +24V OCCUPANCY SENSOR -o a *MOMENTARR +240C _ — _ COMMON COMMON USING FOUR TERMINALS OUT OCCUPANCY SENSOR ON USING FOUR TERMINALS N TIME CLOCK TROK. DG-100 - TIMER AT PANEL 2 1/2-C. TO ABOVE CEILING -PROVIDE BUSHING (TYPICAL) PROVIDE 4'X4' TELEPHONE BOARD PAINTED WITH GREY FIRE RETARDANT PAINT. (2) 3" CONDUITS W/ PULLSTRING TO PROPERTY LINE FOR TELEPHONE AND TV SERVICE TELEPHONE/DATA/TV SINGLE LINE DIAGRAM ._ 1 9" V L_ (STING GRADE FOIL BACKED RED WARNING RIBBON RED EXCAVATE AND BACKFILL. WITH EXISTING SOIL. SCHEDULE 40 P.V.C. CONDUIT FILL AROUND CONDUIT WITH FINE SAND DIRECT BURIED CONDUIT DETAIL NOT TO SCALE PHOTOCELL EXTERIOR LIGHTING CONTACTOR _ PROVIDE 1-8 POLE 30 AMP ELECTRICALLY HELD CONTACTOR AND ROUTE CIRCUITS J THRU CONTACTOR. PROVIDE 120V COIL. PROVIDE PHOTOCELL, MOUNT 6" ABOVE ROOF AND OVER RIDE SWITCH AT PANEL MARKED EXTERIOR LIGHTING . VERIFY NUMBER OVER OF REQUIRED POLES WITH QUANTITY RIDE SWITCH OF NEW AND EXISTING EXTERIOR LIGHTING CIRCUITS. t i tit t- t EXTERIOR LIGHTING CONTROL DIAGRAM NOT TO SCALE RE ALARM CABLES IN CONDUIT. -TO FIRE ALARM DEVICES 120V CIRCUIT 3/4"C. TO TEL. BOARD - SEE NOTE 6 FIRE ALARM CONTROL PANEL FIRE ALARM RISER DIAGRAM NOT TO SCALE FIRE ALARM RISER NOTES 1. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT SIZED PER N.E.C. AND NFPA-70, ARTICLE 760. 2. PROVIDE AND INSTALL ANNUNCIATOR, UNIT SHALL BE FLUSH MOUNTED. 3. SEE MECHANICAL DRAWINGS FOR QUANTITIES AND EXACT LOCATIONS OF DUCT TYPE SMOKE DETECTORS, FLOW AND TAMPER SWITCHES. 4. PROVIDE FIRE ALARM SHUT -DOWN RELAYS AT ALL HVAC EQUIPMENT. 5. REMOTE FIRE ALARM ANNUNCIATOR PANEL SHALL BE BOTH VISUAL AND AUDIBLE. RECEPTACLE WITH WEATHER PROOF COVER. SEE FLOOR PLAN FOR OUTLET RATINGS COUPLING AND PLUG TO BE FLUSH WITH FINISH FLOOR BRASS COUPLING • 6. PROVIDE AUTOMATIC TELEPHONE DIALER. COORDINATE WITH MONITORING COMPANY FOR TYPE OF EQUIPMENT. DIALER SHALL MEET ALL REQUIREMENTS OF NFPA. 7. ALL WIRES SHALL BE IN CONDUIT. LIFE SAFETY BRANCH POWER IS SHOWN AT F.A.C.P. IF ADDITIONAL POWER IS REQUIRED IN A REMOTE POINT FROM F.A.C.P. CONTRACTOR SHALL BE RESPONSIBLE TO RUN NEW WIRING AND CONDUITS AT NO ADDITIONAL COST TO THE OWNER. 8. FIRE ALARM SHALL BE VOICE EVACUATION TYPE. 9. COORDINATE WITH FIRE PROTECTION CONTRACTOR AND FINAL FIRE PROTECTION DRAWINGS TO CONNECT ALL REQUIRED DEVICES OF FIRE PROTECTION SYSTEM TO FIRE ALARM SYSTEM. 4" x 4'' x 2" STAINLESS STEEL BOX WITH GASKET COVER 2" X. rl1-1/2" i FINISHED FL( GALVANIZED RIGID STEEL CONDUIT SURFACE MOUNTED FLOOR OUTLET DETAIL (KITCHEN) NOT TO SCALE LIFTING EYE 1/2" BRASS COUNTER + SINK HOLT (TYPICAL) + + + + + + + 1 /4" GALVANIZED +o+ + + + + + + + + + FLOOR PLATE + + + + + + + + + + + + + + +++++++++++++++++•+ +++++++++++ + + + + + + + + + + + + + + + + ` + STEEL TRAFFIC COVER GALVANIZED STFF I . ARMOR PLATE Q0 12"X12" KNOCKOL TYPICAL FOUR PL♦ HANDHOLE DETAIL NOT TO SCALE um I 0 12" DIA. CONDUIT FLOODLIGHT DETAI NOT TO SCALE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY COARECTiONS REQUIRED DY FIELD INSPECTORS THAT MAY ISE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. r -j f (Orly BIMINI monsoon THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 4� ct 4 v 1 • eA BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E5*A?mmf SWBD MDP MOUNTING: STYLE: ENCLOSURE TYPE: SURFACE SQ. D QO NEMA313 VOLTS & PHASE: 208/120V, 3 PHASE, 4 WIRE AMPS: 2000 M.C.B. OR M.L.O: MCB Al C RATING 65,000 CIR BREAKER LOAD NUM DESCRIPTION POLE I SIZE WIRE/CONDUIT KVA 1 SURGE PROTECTION 3 60 2 PANELS P3A/P3B/P3C 3 225 (4) #4/0, #4G, 2 1/2" C. 57 3 PANELS P4A/P4B 3 225 (4) #4/0, #4G, 2 1/2" C. 55 4 PANEL P3D 3 400 2 SETS: (4) #4/0, #2G, 2 1/2"C. 132.7 5 PANEL DPA 3 1000 3 SETS: (4) #400, #2/OG, 3" C. 372 6 SPARE 3 100 7 SPACE 3 400 8 SPACE PANEL LOAD KVA 616.7 3 AMPS 1714 400 NOTES: @ 208V, 3 PHASE 3 EX. PANEL DPA MOUNTING: SURFACE VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: GE SPECTRA AMPS: 1000 ENCLOSURE TYPE: NEMA 3R M.C.B. OR M.L.O: MCB Al C RATING 65,000 CIR BREAKER LOAD NUM DESCRIPTION POLE SIZE WIRE/CONDUIT KVA 1 PANEL PIA (FORMERLY PANEL A) (EX) 3 200 EXISTING 65 2 PANEL P1B (FORMERLY PANEL KA) (EX)* 3 200 EXISTING 41 3 PANEL P1C (FORMERLY PANEL KB) (EX)* 3 150 EXISTING 55 4 PANELS P2A/P2B (FORMERLY PANELS BA/BB) (EX) 3 200 EXISTING 29 5 RTU-1 (EX) 3 150 EXISTING 37.8 6 RTU-2 (EX) 3 150 EXISTING 22.3 7 RTU-3 (EX) 3 80 EXISTING 23 8 ACCU-1 (EX) 3 3 45 EXISTING 10.1 9 ACCU-2 (EX) 50 EXISTING 8.9 10 AHU-1/2,STIR IPHEAT (EX) 3 100 EXISTING 25.9 13 CHEF'S PANEL * 3 125 (3) #1, #6G, 1 1/2" C. 27 14 COMBO OVEN * 3 125 (3) #1, #6G, 1 1/2" C. 26.6 PANEL LOAD KVA AMPS NOTES: 371.6 1032 @ 208V, 3 PHASE * 65% DEMAND FOR KIT. EQ. MOUSTYNTING: EXISTING NTING: FLUSH PANEL P 1C VOLTS AMPS:& PHASE: 208/12OV, 3 PHASE, 4 WIRE 225 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL KB) M.C.B. OR M.L.O: MLO Al C RATING EX STI NG CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA ABC KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 MOBILE HEATED CABINET #10,#10G , 1/2" 30 1 2 X X X X X X X X X X X X X X X X X X X X X 1.9 3 20 #12,#12G, 1/2" EXIST. HOOD EXH. / MUA FAN 2 3 GAS SKILLET (50) #12,#12G, 1/2" 20 1 0.1 1.9 ) 4 5 SHUNTTRIP 1.9 ) 6 7 GAS RANGE/DUAL OVENS (61) #12,#12G, 1/2" 20 1 1.8 0.6 3 20 #12,#12G, 1/2" HOOD MUA FAN 8 9 SHUNTTRIP 0.6 ) 10 11 ROTISSERIE OVEN (1) #8,#10G, 3/4" 50 3 3.9 0.6 ) 12 13 ) 3.9 0.7 1 20 #12,#12G, 1/2" HOOD LIGHTS/CONTROLS 14 15 ) 3.9 1.8 1 20 #12,#12G, 1/2" WORK TABLE (105) 16 17 SHUNTTRIP 0.9 1 20 #12,#12G, 1/2" SODA SYSTEM (106) 18 19 POS (82) #12,#12G, 1/2" 20 1 1.2 0.9 1 20 #12,#12G, 1/2" GAS FRYERS (65) 20 21 POS (82) #12,#12G, 1/2" 20 1 1.2 SHUNTTRIP 22 23 SODA DISPENSER (90) #12,#12G, 1/2" 20 1 1.5 1 120 SPARE 24 25 REFRIG. CHEF BASE (62) #12,#12G, 1/2" 20 1 0.9 0.8 1 20 #12,#12G, 1/2" REACH -IN REFRIG. (77) 26 27 SHUNTTRIP 1.8 1 20 #12,#12G, 1/2" BEVERAGE TABLE (76) 28 29 PIZZA OVEN (55,56) #12,#12G, 1/2" 20 1 0.4 1.8 1 20 #12,#12G, 1/2" COFFEE BREWER (80) 30 31 EXIST. ICE MACHINE #12,#12G, 1/2" 20 3 1.3 1.8 1 20 #12,#12G, 1/2" BEVERAGE TABLE (89) 32 33 ) 1.3 0.7 1 20 #12,#12G, 1/2" BACK BAR REFRIG. (108) 34 35 ) 1.3 0.6 1 20 #12,#12G, 1/2" BOTTLE COOLER (112) 36 37 ICE TEA BREWER (93) #12,#12G, 1/2" 20 1 1.8 1.8 1 20 #12,#12G, 1/2" COFFEE BREWER (87) 38 39 REACH -IN REFRIG. (94) #12,#12G, 1/2" 20 1 0.8 1.8 1 20 #12,#12G, 1/2" COFFEE BREWER (87) 40 41 SODA DISPENSER (104) #12,#12G, 1/2" 20 1 1.5 1.8 1 20 #12,#12G, 1/2" BEVERAGE TABLE (92) 42 PANEL LOAD KVA AMPS NOTES: PHASE A 21.4 178 1,2,8 PHASE B 15.9 132 PHASE C 16.2 135 TOTAL 53.5 148 @ 208V, 3 PHASE X 65% DEMAND = 34.775 KVA 0 MOUNTING: EXISTIJSH NG PANEL P �A AMLPS.&PHASE: 208/120V, 3 PHASE, 4 WIRE STYL00 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL A) M.C.B. OR M.L.O: MLO Al C RATING EXISTING CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 LIGHTS - KITCHEN #12. #12G, 1/2" 20 1 1.7 X X X X X X X X X X X X X X X X X X XH-. 1.5 1 20 EXISTING EX. BANQUET LIGHTING 2 3 EX. BANQUET LIGHTING EXISTING 20 1 1.5 1.5 1 20 EXISTING EX. BANQUET LIGHTING 4 5 1 EX. BANQUET LIGHTI NG EXISTING 20 1 1.5 X 0.5 1 20 EXISTING EX. BANQUET FB 6 7 EX. BANQUET FANS EXISTING 20 1 1.5 0.5 1 20 EXISTING EX. BANQUET RECEPT 8 9 REC-BAR GP #12. #12G, 1/2" 20 1 0.4 0.5 1 20 EXISTING EX. BANQUET RECEPT 10 11 SPACE X 0.5 1 20 EXISTING EX. BANQUET RECEPT 12 13 SPARE (EX) 20 1 1 20 SPARE 14 15 SPARE (EX) 20 1 1.9 1 20 EXISTING EX.REST WALL SCONCES 16 17 ILIGHTS -BAR #12.#12G, 1/2" 20 1 0.2 1 1 20 EXISTING EXISTING LIGHTING 18 19 RESTAURANT WALL SCONCES #12. #12G, 1/2" 20 1 1.9 1.2 1 20 #12. #12G, 1/2" KIT. GEN'L. RECEPTS 20 21 RESTAURANT CHANDELIERS #12. #12G, 1/2" 20 1 1.6 0.2 1 20 #12. #12G, 1/2" EXTERIOR RECEPTS 22 23 RESTAURANT CHANDELIERS #12. #12G, 1/2" 20 1 1.2 0.6 1 20 #12. #12G, 1/2" KIT. OFFICE RECEPTS 24 25 CEILING FANS -RESTAURANT #12. #12G, 1/2" 20 1 0.3 1 20 SPARE 26 27 RESTAURANT DOWNLIGHTS #12. #12G, 1/2" 20 1 0.2 1.2 1 20 #12. #12G, 1/2" BANQUET CHANDELI ERS 28 29 RESTAURANT DOWNLIGHTS #12. #12G, 1/2" 20 1 0.7 0.6 1 20 #12. #12G, 1/2" CEILING FANS - BANQUET 30 31 SPARE 20 1 0.1 1 20 #12. #12G, 1/2" BANQUET DOWNLIGHTS 32 33 EX. RESTAUARNT RECS EXISTING 20 1 1 0.2 1 20* #12. #12G, 1/2" EXIST. TIME CLOCK 34 35 EX. RESTAUARNT RECS EXISTING 20 1 1 SPACE 36 37 COOLER/FREEZER/KITCHEN LT #12. #12G, 1/2" 20 1 0.8 SPACE 38 39 HOOD LTS/CONTROL #12. #12G, 1/2" 20 1 0.3 SPACE 40 41 BEVERAGE TABLE #12. #12G, 1/2" 20 1 0.3 SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 9.5 79 1,8 PHASE B 10.5 87 PHASE C 8.1 67 TOTAL 28.1 78 @ 208V, 3 PHASE 0 OUNTI NG: , SURFACE PANEL P 2 A AVOLTS MPS: & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: GE POW O ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL BA) M.C.B. OR M.L.O: MLO Al C RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 EX. LOBBY LTS - PENDANTS EX. LOBBY LTS - PENDANTS EX. LOBBY LTS - SCONCE EX. LOBBY LTS - SCONCE. EXISTING 20 1 1.8 X X X X X X X X X X X X X X X X X X 0.5 1 20 EXISTING MERCH. STORAGE LIGHTS 2 3 EXISTING 20 1 1.8 0.5 1 20 EXISTING ATTEND/DRESSING - LIGHTS 4 5 EXISTING 20 1 1.8 X 0.5 1 20 EXISTI NG EXISTING CIRCUIT 6 7 EXISTI NG 20 1 1.8 0.5 1 20 EXISTING EX. CIRCUIT 8 9 EX. PRO SHOP FLOOR BOX EXISTING 20 1 0.5 0.3 1 20 #10, #10G, 3/4" EXTERIOR LIGHTING 10 11 EX. SOUND SYSTEM EXISTING 20 1 0.5 X SPACE 12 13 REC - COUNTER #12,#12G / 1/2" 20 1 0.4 SPACE 14 15 J-BOX - COUNTER #12,#12G / 1/2" #12,#12G / 1/2" 20 20 1 1 0.4 0.4 SPACE 16 17 REC-BACK CONF SPARE SPARE X SPACE 18 19 20 1 SPACE 20 21 20 1 SPACE 22 23 SPARE 20 1 SPACE 24 25 SPARE SPARE 20 1 SPACE 26 27 20 1 SPACE 28 29 SPARE SPARE 20 1 SPACE 30 31 20 1 SPACE 32 33 SPACE SPACE SPACE SPACE 34 35 SPACE 36 37 SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 5 41 1,8 PHASE B 3.5 29 PHASE C 3.2 26 TOTAL 11.7 32 @ 208V, 3 PHASE PANEL SCHEDULE NOTES: ® REFERENCE NOTE ON DRAWING 1. CIRCUITS MAY BE GANGED TOGETHER WITH THE WIRE SIZES INDICATED FOR UP TO THREE CURRENT CARRYING CONDUCTORS IN A CONDUIT. WHEN THE NUMBER OF CURRENT CARRYING CONDUCTORS EXCEEDS THREE, WIRES SHALL BE UPSIZED AND DERATED IN ACCORDANCE WITH NEC TABLE 310.15(B)(2)(a). CONDUIT SIZES SHALL BE ADJUSTED TO COMPLY WITH NEC TABLES FOR CONDUCTOR FILL BASED ON CONDUIT TYPE. 2. CONTRACTOR SHALL VEIjIFY ALL KITCHEN EQUIPMENT POWER REQUIREMENTS PRIOR TO INSTALLATION. 3. SERVICE ENTRANCE RATED. 4. INSTALL NEW BREAKER IN EXISTING PANEL. N MOUNTING: FLUSH PANEL P 1 B VOLTS & PIIASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 200 ENCLOSURE TYPE: NEMA 1 (EXIST. PNL KA) M.C.B. OR M.L.O: MLO Al C RATI NG EXISTING CIR BREAKEP LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA ABC KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 W/I COOLER EVAP. (2) #12,#12G, 1/2" 20 1 0.2 X X X X X X X X X X X X X X X X X X X X 0.95 2 20 #12,#12G, 1/2" FREEZER EVAP (6) 2 3 BEER COOLER EVAP (4) #12,#12G, 1/2" 20 1 0.2 0.95 ) 4 5 FzR DOOR HEAT/LIGHTS (1) #12,#12G, 1/2" 20 1 1.2 X 1.2 3 20 #12,#12G, 1/2" W/I COOLER CU (3) 6 7 SODA SYSTEM (14) #12,#12G, 1/2" 20 1 0.9 1.2 ) 8 9 BENCH MIXER (16) #12,#12G, 1/2" 20 1 1.5 1.2 ) 10 11 FOOD PROCESSOR (18) #12,#12G, 1/2" 20 1 1.5 0.7 3 20 #12,#12G, 1/2" BEER COOLER CU (5) 12 13 DISPOSER (21) #12,#12G, 1/2" 20 3 0.7 0.7 ) 14 15 ) 0.7 0.7 ) 16 17 ) 0.7 2.25 2 30 #12,#12G, 1/2" WATER HEATER 18 19 MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 2.25 20 21 MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 1 20 SPARE 22 23 AI R CURTAIN #12,#12G, 1/2" 20 1 1 1 20 SPARE 24 25 HOBART FLOOR MIXIER (10) #12,#12G, 1/2" 20 3 0.7 1.1 3 20 #12,#12G, 1/2" FREEZER CU (7) 26 27 ) 0.7 1.1 ) 28 29 ) 0.7 1.1 ) 30 31 BOOSTER HEATER (30) #6,#10G, 1" 60 3 5 0.8 3 20 #12,#12G, 1/2" DISPOSER (31) 32 33 ) 5 0.8 34 35 ) 5 0.8 )_ 36 37 DISHWASHER (29) #6,#10G, 1" 60 3 5.5 0.6 1 20 #12,#12G, 1./2" BOTTLE COOLER (116) 38 39 ) 5.5 1 20 SPARE 40 41 ) 5.5 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 22.1 184 1,2,8 PHASE B 19.85 165 PHASE C 21.65 180 TOTAL 63.6 176 @ 208V, 3 PHASE X 65% DEMAND = 41.34 KVA THESE PLANS AND ALL PROPOSED WORK ARE SUDJECT TO ANY CORRECTIONS SQUIRED 19Y FIELD INSPECTORS THAT I lAY BE NECESSARY IN ORDER TO 'COMPLY WITH ALL APPLICABLE CODES. MOUNTING: FLUSH PANEL STYLE: EXISTING ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL P2 BB) B VOLTS & PHASE: AMPS: M.C.B. OR M.L.O: Al RATING 208/12OV, 3 PHASE, 4 WIRE 200 MLO EXISTING CIR DESCRIPTION NUM SPACE 2 CIR BREAKER LOAD PHASE LOAD BREAKER NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT 1 EX. CIRCUIT EXISTING 20 1 0.5 X X X X X X X X X X X X X X X X X X X X X 3 EX. CIRCUIT EXISTING 20 1 0.5 SPACE SPACE 4 6 5 EX. RECEPTACLES EXISTING 20 1 1 7 EX. RECEPTACLES EXISTING 20 1 1 SPACE 8 9 EX. RECEPTACLES EXISTING 20 1 1 1 1 20 EXISTING EXISTING CIRCUIT 10 11 EX. EXIT LIGHTS EXISTING 20 1 0.5 SPACE 12 13 EX. TELEPHONE BOARD EXISTI NG 20 1 0.5 SPACE 14 15 EX. OFFICE REC. EXISTING 20 1 1 1 1 20 EXISTING EX. IG COMPUTER 16 17 EX. OFFICE REC. EXISTING 20 1 1 1 20 SPARE 18 19 EX. LOBBY REC. EXISTING 20 1 1 1 1 20 EXISTING EX. WALL LIGHTING 20 21 EX. LOBBY REC. EXISTING 20 1 1 1 1 20 EXISTING EX. LIGHTING 22 23 SPARE 20 1 1 2 30 EXISTING EX. WATER HEATER 24 25 SPARE 20 1 1 ) 26 27 EX. FIRE ALARM PANEL EXISTING 20 1 0.5 0.2 1 20 #12,#12G, 1/2" CASHIER LIGHTS 28 29 EX. RECESSED LTG EXISTI NG 20 1 1 1.2 1 20 #12, #12G, 1/2" PRO SHOP PENDANT LIGHTS 30 31 EX. RECESSED LTG EXISTI NG 20 1 1 1.2 1 20 #12, #12G, 1/2" PRO SHOP PENDANT LIGHTS 32 33 PRO SHOP LIGHTS #12, #12G, 1/2" 20 1 1.5 1 1 20 EXISTING EX. LIGHTING 34 35 PRO SHOP LIGHTS #12, #12G, 1/2" 20 1 0.9 SPACE 36 37 EX. WALL LIGHTS EXISTING 20 1 1 UNUSABLE SPACE 38 39 OFFICE 121/122 LIGHTS #12, #12G, 1/2" 20 1 0.3 UNUSABLE SPACE 40 41 EX. EXIT LIGHTS EXISTING 1 0.5 UNUSABLE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 8.2 68 1,8 PHASE B 10 83 PHASE C 7.1 59 TOTAL 25.3 70 @ 208V, 3 PHASE 5. PROVIDE SHUNT TRIP BREAKER. 6. ROUTE THROUGH LIGHTING CONTACTOR. 7. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL TRIP BREAKER. 8. PRIOR TO BID FIELD VERIFY WHICH BREAKERS MAY BE RE -USED AND WHICH BREAKERS ARE REQUIRE TO BE NEW. a.. SHAFFER ENCiI(Y' rl pis CRO502 C 1 • f2����f J69EO�f1l.Suile 502 i �♦ �y e 4�D 3 d wg0O?yff6 ffe���723 82at ,pZJ. Bfi AN ® No 111618 4 0 Ft `p •, �� ............._ ...._!ice S1�.N..p.�.. `.��°�............... THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. ^ll +, n U v1 c� l O V1 V • A f^1 , ie� BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.cem Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E6,0 MOUNTING: SQSURFACE PANEL P3A AMPS; VOLTS &PHASE: 208/12OV,3PHASE, 4W21Z5 STY: ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO Al C RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER I CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-MEMBER DINING #12, #12G / 1/2" 20 1 0.7 X X X X X X X X X X X X X X X X X X X X X 0.4 1 20 #12, #12G / 1/2" FACP 2 3 REC-M EMBER DI NI NG #12, #12G / 1/2" 20 1 0.5 0.9 1 20 #12, #12G / 1/2" REC-155 4 5 REC-DINING SERVICE #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-LOCKER 145 6 7 REC-DINING SERVICE #12, #12G / 1/2" 20 1 0.2 0.2 1 20 #12, #12G / 1/2" REC-147 8 9 REC-DINING SERVICE #12, #12G / 1/2' 20 1 0.2 0.2 1 20 #12, #12G / 1/2" REC-147 10 11 REC-LOCKER 130 #12, #12G / 1/2" 20 1 0.5 0.4 1 20 #12, #12G / 1/2" REC-147 12 13 REC-LOCKER 130 #12, #12G / 1/2" 20 1 0.2 0.2 1 20 #12, #12G J 1/2" REC-150 14 15 REC-LOCKER 130 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-150 16 17 REC-LOCKER 132 #12, #12G / 1/2" 20 1 0.2 0.2 1 20 #12, #12G / 1/2" REC-151 18 19 REC-LOCKER 132 #12, #12G / 1/2" 20 1 0.2 0.5 1 20 #12, #12G / 1/2" REC-150 20 21 REC-LOCKER 137 #12, #12G / 1/2" 20 1 0.2 0.4 1 20 #12, #12G / 1/2" REC-112,113 22 23 REC-132, 134, 138 #12, #12G / 1/2" 20 1 0.5 0.9 1 20 #12, #12G / 1/2" REC-156 24 25 REC-143 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-145 26 27 REC-143 #12, #12G / 1/2" 20 1 0.4 0.4 1 20 #12, #12G / 1/2" REC-124 FLOOR BOXES 28 29 REC-123, 140 #12, #12G / 1/2" 20 1 0.9 1 20 SPARE 30 31 DISPLAY LIGHTING #12, #12G / 1/2" 20 1 1 1 20 SPARE 32 33 DISPLAY LIGHTING #12, #12G / 1/2" 20 1 1 1 20 SPARE 34 35 REC-140, 141 #12, #12G / 1/2" 20 1 0.4 1 20 SPARE 36 37 REC-159 #12, #12G / 1/2" 20 1 0.5 1 20 SPARE 38 39 REC-157 #12, #12G / 1/2" 20 j 1 0.7 1 20 SPARE 40 41 REC-158 #12, #12G / 1/2" 20 1 1 0.4 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 4.7 39 1,2 PHASE B 5.5 45 PHASE C 5 41 _ TOTAL 15.2 42 @ 208V, 3 PHAS I - SURFACE & PHASE: 208/12OV, 3 PHASE, 4 IRE MOUNTING: SQ. D NQOD PANEL P 3 D AMPS. 4 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO Al RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B G- KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 RTU-1 #8, #10G, 1" 3 45 3.8 X X X X X X X X X X X X X X X X X X X X X 0.1 2 15 #12, #12G, 3/4" FCU-1 2 3 ) 3.8 0.1 1 ) 4 5 ) 3.8 0.1 2 15 #12, #12G, 3/4'' FCU-2 6 7 RTU-2 #8, #10G, 1" 3 45 3.8 0.1 ) 8 9 ) 3.8 0.1 2 15 #12, #12G, 3/4" FCU-3 10 11 ) 3.8 0.1 ) 12 13 RTU-3 #2, #8G, 1 1/2" 3 100 8.2 0.1 2 15 #12, #12G, 3/4" FCU-4 14 15 ) 8.2 0.1 ) 16 17 ) 8.2 1.7 2 30 #10, #10G, 3/4" HP-1 - CIRCUITA 18 19 RTU-4 #2, #8G, 1 1/2" 3 100 9.5 1.7 ) 20 21 ) 9.5 1.7 2 30 #10, #10G, 3/4" HP-1 - CIRCUIT B 22 23 ) 9.5 1.7 ) 24 25 RTU-5 #2, #8G, 1 1/2" 3 100 8.2 1 1 20 #12, #12G, 3/4" EF'S NORTH 26 27 ) 8.2 1 1 20 #10, #10G, 3/4" EF'S SOUTH 28 29 ) 8.2 SPACE 30 31 RTU-6 #2, #8G, 1 1/2" 3 100 8.2 SPACE 32 33 ) 8.2 SPACE 34 35 ) 8.2 SPACE 36 37 SPACE SPACE 38 39 SPACE SPACE 40 41 SPACE I I I SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 44.7 372 PHASE B 44.7 372 PHASE C 45.3 377 TOTAL 134.7 374 @ 208V, 3 PHASE PANEL SCHEDULE NOTES: ® REFERENCE NOTE ON DRAWING 1. CIRCUITS MAY BE GANGED TOGETHER WITH THE WIRE SIZES INDICATED FOR UP TO THREE CURRENT CARRYING CONDUCTORS IN A CONDUIT. WHEN THE NUMBER OF CURRENT CARRYING CONDUCTORS EXCEEDS THREE, WIRES SHALL BE UPSIZED AND DERATED IN ACCORDANCE WITH NEC TABLE 310.15(B)(2)(a). CONDUIT SIZES SHALL BE ADJUSTED TO COMPLY WITH NEC TABLES FOR CONDUCTOR FILL BASED ON CONDUIT TYPE. 2. PROVIDE SUB —FEED LUGS. 3. CONTRACTOR SHALL VERIFY ALL KITCHEN EQUIPMENT POWER REQUIREMENTS PRIOR TO INSTALLATION. 4. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL TRIP BREAKER. 5. ROUTE THROUGH LIGHTING CONTRACTOR. �� MOUNTING: SQ. D NQ PANEL P 3 B AMPS. NTING: &PHAS E: 208/120V, 3 PHASE, 4 W1RE STY25 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO Al C RATI NG 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 LIGHTS-123,126,127 #10, #10G, 1/2" 20 1 0.5 X X 1 X X X 1 X X X X X X X X X X X X X X 0.2 1 20 #12, #12G, 1/2" LIGHTS - MERCH. STOR. 2 3 LIGHTS - MEMBER DINING #10, #10G, 1/2" 20 1 0.7 0.4 1 20 #10, #10G, 1/2" EXTERIOR LIGHTS - S 4 5 LIGHTS - MEMBER DINING #10, #10G, 1/2" 20 1 1 1.5 X 1.1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LOCKER 146 6 7 LIGHTS - MEMBER BAR #10, #10G, 1/2" 20 1 0.9 1.1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LAV. 147 8 9 LIGHTS - MEMBER BAR #10, #10G, 1/2" 20 1 1.5 1.1 1 20 #12, #12G, 1/2" LIGHTS - MENS LOCKER 151 10 11 LIGHTS - HALLS #10, #10G, 1/2" 20 1 1.1 X 1.3 1 20 #12, #12G, 1/2" LIGHTS - MENS LAV. 149 12 13 LIGHTS - MTG & ANTI ROOMS #12, #12G, 1/2" 20 1 1 1.4 1.1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LOCKER 137 14 15 LIGHTS - GALLERY #12, #12G, 1/2" 20 1 1.7 1.1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LAV. 136 16 17 DISPLAY CASES - GALLERY #12, #12G, 1/2" 20 1 1.8 1.1 1 20 #12, #12G, 1/2" LIGHTS - MENS LAV. 149 18 19 LIGHTS - TERRACES #10, #10G, 1/2" 20 1 1.1 1.1 1 20 #10, #10G, 1/2" LIGHTS - MENS LOCKER 151 20 21 ILIGHTS - TERRACES #10, #10G, 1/2" 20 1 1.8 1.1 1 20 #10, #10G, 1/2" LIGHTS - MENS LOCKER 151 22 23 LIGHTS -TERRACES #12, #12G, 1/2" #10, #10G, 1/2" #10, #10G, 1/2" #12, #12G, 1/2" #12, #12G, 1/2" #12, #12G, 1/2" #12, #12G, 1/2" 20 20 20 20 20 20 20 1 1 1 1 1 1 1 1.8 0.7 1.5 1.4 1.8 1.6 1 1.1 1 20 #10, #1OG, 1/2" LIGHTS - MENS LOCKER 151 24 25 LIGHTS -PAVILION 1 20 SPARE 26 27 LIGHTS - PAVI LION 0.2 1 20 #12, #12G, 1/2" LIGHTS 119 28 29 LIGHTS - PRIVATE DINING 1.2 1 20 #12, #12G, 1/2" LIGHTS 119 30 31 LIGHTS - GALLERY 1.2 1 20 #12, #12G, 1/2" LIGHTS 119 32 33 LIGHTS 119 1 20 SPARE 34 35 LIGHTS 119 1 20 SPARE 36 37 SPARE 20 1 1 20 SPARE 38 39 SPARE 20 1 1 20 SPARE 40 41 SPARE 20 1 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 11.1 92 1,2 PHASE B 12.7 105 PHASE C 14.4 119 TOTAL 38.2 106 @ 208V, 3 PHASE MOSTYUNTING: SQ.�UNQ PANEVOLTS L P4A AMPS:& PHASE: 208/120V, 3 PHASE, 4 2125 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MILO Al C RATI NG 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA ABC KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 ROLL -IN REFRIG. (122) #12,#12G / 1/2" #12,#12G / 1/2" 20 20 1 1 1 1.1 X X X X X 1 X X X X X X X X X X X X X 5 3 60 #6,#10G / 3/4" BOOSTER HEATER (149) 2 3 REACH -IN FREEZER (123) 5 ) 4 5 HOOD LTS/CONTROLS (125) #12,#12G / 1/2" 20 1 0.3 X 5 ) 6 7 HOOD EXH. FAN #12,#12G / 1/2" 20 3 1.1 5.5 3 60 #6,#10G / 3/4" DISHWASHER (153) 8 9 ) 1.1 5.5 ) 10 11 ) 1.1 X 5.5 ) 12 13 HOOD MUA FAN #12,#12G / 1/2" #12,#12G / 1/2" 20 20 3 1 0.6 0.6 0.6 0.8 0.8 3 20 #12,#12G / 1/2" DISPOSER (149) 14 15 ) 0.8 ) 16 17 ) X 0.8 ) 18 19 GAS DUAL FRYER (126) 0.9 1 20 #12,#12G / 112" SODA SYSTEM (156) 20 21 SHUNT TRI P 1.5 1 20 #12,#12G / 1/2" SODA DISPENSER (159) 22 23 REFRIG. PIZZA PREP TBLE(133) #12,#12G / 1/2" 20 1 1.1 1.8 1 20 #12,#12G / 1/2" BEVERAGE TABLE (162) 24 25 POS SYSTEM PRINTER (72) #12,#12G / 1/2" 20 1 0.3 1 20 SPARE 26 27 REFRIG. CHEF BASE (130) #12,#12G / 1/2" 20 1 0.7 1 20 SPARE 28 29 SHUNTTRIP 1 20 SPARE 30 31 SPARE _ 20 20 20 20 20 20 1 1 1 1 1 1 SPACE 32 33 SPARE SPACE 34 35 SPARE SPACE 36 37 SPARE SPACE 38 39 SPARE SPACE 40 41 SPARE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 16 133 1,2,3 PHASE B 16.3 135 PHASE C 16.2 135 TOTAL 48.5 134 @ 208V, 3 PHASE X 65% DEMAND = 31.525 KVA 0 w0 MOUNTING: SURFACE PANEL P3 C VOLTS & PHASE 208/12OV, 3 PHASE, 4 WIRE STYLE: SQ. D NQ AMPS: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.CI: MLO Al C RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-TERRACE TV'S #12, #12G, 1/2" 20 1 0.7 X X X X X X X X X X X X X X X X X X X X 0.2 1 20 #8, #8G, 1" REC-EVENT LAWN 2 3 GALLERY DISPLAY TVS #12, #12G, 1/2" 20 1 0.5 0.2 1 20 #8, #8G, 1" REC- EVE NT LAWN 4 5 GALLERY DISPLAY TVS #12, #12G, 1/2" 20 1 0.5 X 0.3 1 20 #10, #10G, 3/4" EXT. LIGHTI NG-N 6 7 REC-BAR TV'S #12, #12G, 1/2" 20 1 0.9 0.5 1 20 #10, #10G, 3/4" REC-ROOF TOP 8 9 SPARE 20 1 SPACE 10 11 SPARE 20 1 SPACE 12 13 ISPARE 20 1 SPACE 14 15 SPARE 20 1 SPACE 16 17 SPARE 20 1 SPACE 18 19 SPARE 20 1 SPACE 20 21 SPARE 20 1 SPACE 22 23 SPARE 20 1 SPACE 24 25 SPARE 20 1 SPACE 26 27 SPARE 20 1 SPACE 28 29 SPARE 20 1 SPACE SPACE SPACE SPACE 30 32 34 36 31 SPARE 20 1 33 SPARE 20 1 35 SPARE 20 1 37 SPACE I SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 2.3 19 PHASE B 0.7 5 PHASE C 0.8 6 TOTAL 3.8 10 @ 208V, 3 PHASE HUNTING: SQFLDUNQH ENCLOSURE TYPE: NEMA 1 PANEL P4 B VOLTS AMPS &PHASE: 208/120V, 3 PHASE, 4 WIRE M.C.B. OR M.L.O: MLO Al C RATING 10,000A CIR I WIRE/CONDUIT DESCRIPTION NUM #12,#12G / 1/2" ICE TEA BREWER (164) 2 CIR BREAKER LOAD PHASE LOAD BREAKER NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA ABC KVA POLEI SIZE 1 GAS PIZZA OVEN (135) #12,#12G / 1/2" 20 1 0.1 X X X X X X X X X X X X X X X X X X X X 1.8 1 20 3 PIZZA OVEN VENT FAN (136) #12,#12G / 1/2" 20 1 0.4 0.7 1 20 #12,#12G / 1/2" REFRIG. (165) 4 5 REF. SANDWICH UNIT (138) #12,#12G / 1/2" 20 1 0.7 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 6 7 SOUP WELLS (140) #12,#12G / 1/2" 20 1 1.6 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 8 9 WORK TOP REFRIG. (142) #12,#12G / 1/2" 20 1 1.1 1.8 1 20 #12,#12G / 1/2" #12,#12G / 1/2.1 #12,#12G/ 1/2" #12,#12G / 1/2" #12,#12G / 1/2" POPCORN MAKER (185) 10 11 SOUP WELLS (140) #12,#12G / 1/2" 20 1 0.8 0.2 1 20 REFRIG. (186) 12 13 SPARE 20 1 1.8 1 20 COFFEE BREWER (187) 14 15 SPARE 20 1 0.8 1 1 20 HOT DOG ROLLER (188) 16 17 ICE MACH. (158) #12,#12G / 1/2" 20 1 1.4 0.5 1 20 BUN WARMER (189) 18 19 WINE CHILLER (175) #12,#12G / 1/2" 20 1 0.4 0.7 1 20 #12,#12G / 1/2" DRAFT BEER COOLER (178) 20 21 BACKBAR COOLER (176) #12,#12G / 1/2" 20 1 0.7 1.3 1 20 #12,#12G / 1/2" GLASSWASHER (181) 22 23 GLASS CHILLER (177) #12,#12G / 1/2" 20 1 0.7 0.6 1 20 #12,#12G / 1/2" POS (82) 24 25 1 BOOSTER HEATER (180) #8,#10G / 3/4" 40 3 3.3 0.7 1 20 #12,#12G / 1/2" REC-BAR 26 27 ) 3.3 1 20 SPARE 28 29 ) 3.3 1 20 SPARE 30 31 REC-BAR #12,#12G / 1/2" 20 1 0.4 1 20 SPARE 32 33 REC-KITCHEN 127 #12,#12G / 1/2" 20 1 0.5 1 20 SPARE 34 35 WH-P7A #10, #10G, 3/4" 30 2 2.4 1 20 SPARE 36 37 ) 2.4 1 20 SPARE 38 39 WH-P7A 20 1E SPACE41 SPACE 1X SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 15 125 1,2,3 PHASE B 10.7 89 PHASE C 12.4 103 TOTAL 38.1 105 @ 208V, 3 PHASE X 65% DEMAND = 24.765 KVA E THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED RY FIELD INSPECTORS THAT MAY BE t4ECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. �._ SHAFFER ENCINEENINC $IOUP.LLC 12058 San Jo Blvd. SuR, 502 ".�y 2223 uww shaffereg. can `A...SHAizk�zleottzzazes3......... J A F �c1 58168 -• '7' tAo cG ' Lu .........t�._ . fir............... �.'.,....iC...,. ��..._...............i/ f,li.IIV11.a".0 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMBED TO SUCH USE. V1 cj 4_4 ct • • A f^l, • • BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. L E 6,0 E Design Group, Inc, Jacksonville, F►orida 904-543-7670 www.,Jaxciesigngroup.com Foodservice Consulting & Design tra N 12 -- 1 12 w wCD CD C - 3060 - 3060 3060 Mech plans 19 (� ■® KIfil 57 -7 rilVON l ro F=_E m ill► mil il11 Lt�q Il► mil ON il ON I►�=�11►. VON . mMAI--_�� V Chi CUP- , 30 (3 �1 ' I ' rowo 100 L �- 3I 10 c28 F= � Fz 101 0 1824 row Wannamaker Room Dining 1460 �n c� N 96) 89 90 92 82 (9� O �91 93 0 0 �10 ' 104 A0 � s i �20 ------------ i 3060 ; 3072 Back Cooking Line Elevation 79 9 L> Cut back wall at end of existing bar top here 111 95 19th Hole Dining THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT ---MAY BE MCESSAWY IN ORDER TO MIMPLY WITH ALL APPLICABLE CODES, ■I�III�.III�III� IIIIIIIIIIIILIIIIIIIIIIIIIIIIIIIIII-a - �� III 62 61 Main I Cooking Line Elevation I! 55 EQUIPME NT SCHEDULE ITEM QTY DESCRIPTION EXISTING NEW 1, 1 WALK-IN COOLER/FREEZER/BEER COOLER X 2, 1 COOLER EVAPORATOR C❑IL - X 3. 1 COOLER REMOTE C/U - - X 4. 1 BEER COOLER EVAPORATOR C❑Il_ X . 1 BEER COOLER REMOTE C/U W/STACKING RACK X 6. 1 FREEZER EVAPORATOR C❑IL X 7, 1 _ FREEZER REMOTE C/U X 97- 2 DUNNAGE RACKS 9. 1 BEER KEG RACK X 10, 1 FLOOR MIXER - X 11. 1 LOT STORAGE SHELVING UNITS - X 12, 2 M❑BILE PAN RACKS X 13, 1 LOT _ M❑BILE STORAGE SHELVING UNITS X 14. 1 LOT BAG IN A BOX SODA SYSTEM, RIL❑CATED•- BY VENDOR X 15, I 1 S/S MOBILE MIXER STAND X 16, 1 BENCH MIXER, RELOCATED X 17, 1 SLICER, RELOCATED X 18. 1 FOOD PROCESSOR, RELOCATED___ X 19, 1 S/S PREP TABLE W/SINK X 20. OPEN NUMBER 21, 1 _- DISP❑SER X 22, 1 S/S WALLSHELF X 1 WATER HEATER �- 24, 1 AIR DOOR - X 25, 1 LOT, FIRE SUPPRESSI❑N SYSTEM TO BE RE=N❑VATED-BY VENDOR/OWNER X 26. 1 S/S CLEAN DISHTABLE X 27, 1 S/S WALLSHELF X 28, 3 S/S FLOOR TROUGHS 29, 1 -LOW TEMP CONVEYOR DISHWASHER- BY VENDOR 30. 1 ELECTRIC HOT WATER BOOSTER HEATER X 31, 1 DISP❑SER X 32, 1 _ S/S SOILED DISHTABLE W/RACK_ SHE=LF X 33. 1 HOSE REEL X 34, 2 NEW WALL MOUNTED HANDSINKS X 1 M❑BILE HEATED CABINET, RELOCATED X 36, 1 S/S M❑BILE PREP TABLE X 37. 1 MOBILE CART - X 4 UNDERCOUNTER INGREDIENT BINS: X 39, 1 S/S MOBILE PREP TABLE X X 40. 1 - WALL MOUNTED HANDSINK 41. _ OPEN NUMBER 42, 1 _ GAS 6 BURNER RANGC W/❑VEN X 43. 1 ELECTRIC R❑TISSERIE OVEN_ X 44, 1 ELECTRIC C❑MBINATION OVEN - X 45, 1 LOT EXHAUST SYSTEM W/MAKE-UP AIR X 46. 1 LOT S/S WALL FLASHING -_ X 47. 1 S/S FLOOR TROUGH X 48. 1 _- 3 COMPARTMENT SINK, RELOCATED X 49. 1 S/S WALLSHELF, RELOCATED X 50, 1 GAS TILT SKILLET W/WATER FIL_.LER FAUCET X 51. OPEN NUMBER 52, OPEN NUMBER ' _ OPEN NUMBER 54. _ OPEN NUMBER 55, 1 _ GAS PIZZA ❑VEN X 56. 1 LOT PIZZA OVEN VENTILATION X X 57. 1 S/S MOBILE W❑RKTAI;LE - 58. 1 LOT EXHAUST SYSTEM W/WALL FLASHING X 59. 1 GAS SALAMANDER BROILER X 60. OPEN NUMBER X 61, 11 GAS RANGE W/D❑UBL-E OVENS 62, 11 _ REFRIGERATED CHEFS BASE - X 63. 1 _ GAS CHARBROILER -_ X 64. 1 GAS GRIDDLE X 65, 1 GAS DUAL FRYER W/FILTRATI❑N & RIGHT SIDE SPLASHGUARD X 66. 1 REACH -IN FREEZER X 67, 1 FIRE EXTINGUISHER- BY GC - X 68, 1 ROTARY TOASTER - PHEAT 69, 2 LAMPS X 70, 1 S/S CHEF'S COUNTER X 2 COUNTERTOP SOUP WELLS - X 72, 4 POS SYSTEM PRINTERS- BY VENDOR/OWNER, SEE FS-2 X 73. 1 REFRIGERATED SANDWICH UNIT X 74. 1 _ MICR❑WAVE OVEN X 75. 1 _ HANDSINK X 76. 1 REFRIGERATE=D PIZZA PREP TABLE W/DBL ❑VERSHELF X 77. 1 REACH -IN BEVERAGE REFRIGERAT❑R X 78, 1 S/S BEVERAGE TABLE= X 79, 1 - S/S DOUBLE WALLSHELF X 80, 1 COFFEE BREWER- BY VENDOR X 81, 2 ICE TEA DISPENSERS- BY VENDIIR X 82. 1 LOT P❑S SYSTEM/CASH REGISTERS- BY"VENDOR/OWNER, SEE FS-2 X 83. 1 PASS-THRU ICE BIN W/C❑LD PLATE X 84. 1 HANDSINK 85, 2 M❑BILE GLASS RACKS X 86. 1 _ MOBILE DISH DOLLY X 87, 12 COFFEE BREWERS- BY VENDOR X 88, 2 S/S WALLSHELVES 89, 1 S/S M❑BILE BEVERAGE TABLE -_ 90, 1 SODA DISPENSER W/ICE BIN- BY VENDOR X 91. 2 ICE TEA DISPENSERS- BY VENDE-IR X 92, 1 S/S MOBILE BEVERAGE TABLE X 93, 1 - ICE TEA BREWER- BY VENDOR X 94. 1 _ REACH -IN REFRIGERATOR X 95. 1 LOT SLIM JIM TRASH CANS- BY OWNER X 96. 2 LIQU❑R STORAGE SHELVING UNITS X 97, 1 MOP SINK- BY GC X 98, 1 MOP HANGER X 99. 1 CHEMICAL STORAGE SHELVING UNIT X 100, 1 HANDSINK X 101. 1 LOT DRY STORAGE SHELVING UNITS X 102, 1 ICE MACHINE X 103, 1 (FUTURE) HANDSINK 104. 1 (FUTURE) SODA DISPENSER W/ICE BIN- BY VENDOR 105, 1 (FUTURE) S/S WORKTABLE 106, 1 LOT (FUTURE) BAG IN A BOX SODA SYSTEM- BY VENDOR 107.11 LOT SOLID SURFACE BACKBAR TOP- 3Y GC/MIL-LW❑RK CONTR. X 108, 1 UNDERC❑UNTER BACKBAR REFRIGE_RAT❑R X 109, 1 DRAFT BEER TAPS & DRAINER- ❑N ITEM 107 X 110. 2 _MOUNTED HEATED BANQUET CARTS- NOT SHOWN ON PLAN X 111, 1 S/S HANDSINK X 112. 1 BOTTLE COOLER X 113, 1 _- 3 COMPARTMENT BAR SINK X 114, 1 BLENDER STATI❑N W/DUMP SINK X 115, 1 ICE BIN W/C❑LD PLATE X X 116, 1 BOTTLE COOLER TIME CLOCK CHEF'S LINE BREADj SOUP BOWL WARMER CHEF'S LINE REFRIG RATED SAL6tD/DRESSINGS STATION (FUTURE) M❑BILE ST RAGE SHELVING UNITS 117, 1 X 118, 1 X 119. 1 X 120. 2 r � u long THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. W nn I IW V I W 0 r +> I _ d U `-I•--- W `u-) CL - O �1 o L_J CL f PLANNING -ARCHITECTURE t.ANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic Nos.: AA26000580 LC26000508 FOODSERVICE FLOORPLAN MAIN KITCHEN RENOVATION SCALE: 1 /4"=1 '0" DRAWN BY JZ CHECKED BY GV DATE --6-?014 JOB NO. 3-40 SHEET NO. G LIF THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED SY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICADLE CODES. Cooking Line leVOLion EQUIPMENT SCHEDL)LE ITEM QTY DESCRIPTION 121, 2 STORAGE SHELVING UNITS 122, 1 _ R❑LL-IN REFRIGERAT❑R 123, 1 _ REACH -IN FREEZER 124, 1 LOT S/S WALL FLASHING 125, 1 LOT E=XHAUST SYSTEM W/MAKE-UP AIR _ GAS FRYER BATTERY W/FILTRAT I❑N & LEFT SIDE SPLASHGUARD GAS SALAMANDER BR❑ILER GAS 8 BURNER RANGE W/DUAL OVENS 126, 1 127, 1 128, 1 129, 1 GAS 24" CHARBR❑ILER 130, 1 REFRIGERATED CHEFS BASE GAS 36" GRIDDLE FIRE SUPPRESSI❑N SYSTEM - R.EFRIGERATED PIZZA PREP TABLE S/S WALLSHELF GAS PIZZA OVEN PIZZA OVEN VENTILATI❑N 1 132, 1 LOT 133, 1 134, 1 135, 1 136, 1 LOT 137, 3 HANDSINKS 138, 1 R'EFRIGERATED SANDWICH UNIT S/S MOBILE WORKTABLE W/DRAWERS _ C DUNTERTOP SOUP WELLS OPEN NUMBER W❑RKT❑P REFRIGERATOR W/2 DRAWERS; & 1 DOOR S/S DOUBLE WALLSHELF S/S DOUBLE WALLSHELF - -: COMPARTMENT SINK MILLWORK SERVICE C❑UNTER = BY GC✓MW❑RK CONTRACTOR MILLWORK SERVICE C❑UNTER = BY GC✓MW❑RK CONTRACTOR FIRE EXTINGUISHER- BY GC ELECTRIC HOT WATER BOOSTER HEATED? 139, 1 140, 2 141, 142, 1 143, 1 144, 1 145, 11 146, 11 147, 1 148, 1 149, 1 150. 1 S/S WALL MOUNTED GLASS RACK SHEL_I= 15L 1 S/S SOILED DISHTABLE _ DISPOSER - LOW TEMP CONVEYOR DISHWA';HER- BY VENDOR S/S CLEAN DISHTABLE S/S WALLSHELF - 152, 1 153, 1 154, 1 155, 1 156, 1 LOT BAG IN A BOX SODA SYSTEM- BY VEN I)OR 157, 1 S/S FLOOR TROUGH ICE MACHINE W/BIN & WATER FILTER 158, 1 159, 1 SODA DISPE=NSER W/ICE BIN- BY VEND❑R HOSE REEL 160, 1 161. 1 S/S DOUBLE WALLSHELF 162, 1 S/S M❑BILE BEVERAGE TABLE W/GLASS RACK SLIDES 163, 12 ICE TEA DISPENSERS- BY VENDOR 164, 11 ICE TEA BREWER- BY VENDOR 165, 1 W'❑RKT❑P REFRIGERATOR 166, 2 COFFEE BREWERS- BY VENDOR 167, 1 MOP SINK- BY GC/MECHANICAL CONTRA('- TOR 168, 1 CHEMICAL STORAGE SHELF W/M❑P HAN(=DER 169, OPEN NUMBER 170, OPEN NUMBER 171, OPEN NUMBER 172. 1 HANDSINK WITH SPEEDRAIL 1 1 ICEBIN WITH C❑LDPLATE & SPEEDRAIL 174, OPEN NUMBER 175, 1 WINE CHILLER 176, 1 BACKBAR COOLER 177, 1 GLASS FROSTIER 178, 1 3 TAP DRAFT BEER COOLER 179, 1 _ STORAGE CABINET LESS DOORS 180, 1 HOT WATER BOOSTER HEATER FOR ITEM 181-BY GC/MECH 181, 1 GLASS WASHER- BY VENDOR 182. 1 DUMP SINK/ST❑RAGE UNIT 183, 1 CENTER ISLAND DISPLAY -BY GC/MILLWORK CONTRACTOR 184, 1 MILLWORK SERVICE COUNTER -BY GC/MILLWORK CONTRACTOR 185, 1 E;XISTING POPCORN MAKER, RELOCATED 186, 1 UNDERC❑UNTER REFRIGERATOR 187, 1 COFFEE BREWER- BY VENDOR 188, 1 HOT DOG ROLLER W/SNEEZEGUARD 189, 1 BUN WARMER -_ 190, j OPEN NUMBER IT A. Design Group, Inc, Jacksonville, Florida 904-543-7670 www. jaxdesigngroup,com Foodservlce Consulting & Design r m i _o o_ w 0 CC w Q 0 0 Z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. W ' n� W �n 0i W U CU U T W 0 CL - 4_, O � S IUD (Tl n UD n BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.coin Lic. Nos.: AA26000586 LC26000508 FOODSERVICE FLOORPLAN MEMBER'S KITCHEN & BAR SCALE: 1 /4"=1 '0" DRAWN BY JZ LHECKED BYCvDATE-26-0I4 JOB N0. 1 _4( SHEET NO. 22- .,ter r- i u r n/zcncrY tIVUlJ 11V1'VIL1V11`i11V1V — NVV / elvvVv/ EXHAUST PLENUM HOOD CONFIG, HOOD No, TAG MODEL LENGTH MAX. COOKING TEMP. TOTAL SUPPLY CFM HOOD CONSTRUCTION T❑TAL EXH. CFM _- e - e RISER(S) , DIA. CFM S.P. WIDTHF12 END T❑ END ROW ---4 -- - - 6030 15' 3.00" 450 2700 10' 1350-0,263" 2160 430 SS ALONE ALONE 10' 1350 -0.263" 1 45 ND-2-PSP-F Deg Where Exposed 5430 13` 6 00" 600 3.-75 10' 1687 -0,633" 2700 430 SS2 ALONE ALONE 10' 1687 -0,633" 125 ND-2-PSP-FDeg' Where Exposed nVV1J 11V1'VI11VI.M11V1V FILTER(S) LIGHT(S) UTILITY CABINET(S) HOOD WIRE FIRE SYSTEM ELECT L❑CATI❑N TYPE SIZE MODE NO TAG TYPE QTY. HEIGHT LENGTH QTY, TYPE GUARD i 45 SS Baffle with Handles 11 20' 16' 8 Incandescent No 2 125 Captrate Solo Filter 10 r 20 r 16 6 Incandescent NO Left Ansul R102 3.0/'3,0 DCV YTe' 7% in r-f m Tn I TCV 11VV1> IH❑OD NO, V1 11L/1Vk-1) TAG FIELD WRAPPER 12.00' BACKSPLASH 80.00' High - ❑PTI❑N High Front, Left, X 186,00' Lorg Right 430 SS 1 45 LEFT SIDESPLASH 80.00' High X 12,00' I -Ong LEFT END STANDOFF (FINISHED) 3' Wide BALANCE DAMPERS STRUCTURAL FRONT PANEL RIGHT VERTICAL END PANEL 27' Top Wi,Ath, SS FIELD WRAPPER 12,00' High Front, Left, BACKSPLASH 80,00' High X 174,00" Lorg BALANCE DAMPERS STRUCTURAL FRONT PANEL 430 SS 60' Long 21' Bottom Width,, 80' High Insulated 430 Right 430 SS 2 125 T-)T71nT7. /17-)A/PL-TT1 OrTDDT V DT L7ATTTAf.1Q i d dJ1Y1 HOOD NO. VlYtZdLL TAG POS. LENGTH WIDTH HEIGHT TYPE WIDTH RISER(S) LEN& DIA, CFM SS.P. 1 45 Front 186' 12, 6' MUA 10" 1 28' _540 ; 0,137' _ MUA 10" 28' 28" _ —540 5.40 0.137" 0,137" MUA 10' MUA 10" 28' _ 540 C 137" 2 125 Front 174' 14' 6 MUA 12' 28" 6-17 5 0.173' I MUA 12" 28' 675 0.173" MUA 12' 28' 675 0,173" MUA 12' 28' 675 0.173' L�vr3Pwrrc+T �I AT TATh-nz AfA)irrrnAT — Tn-UI QiP4 nr,7 L FAN M UNIT UNIT TAG FAN UNIT MODEL # CFM ESP. RPM H,P, 0 VOLT FLA WEIGHT (LBS,) S❑NES NO, 1 NCA18HPFA 2700 I 1,500 1181 2,000 3 208 6,2 195 14.2 c NCA24HPFA 3375 2.000 1047 3,000 3 208 9.5 256 20 VT TA FA AT TNFnRMATmAT - TnhB 1 AlS.5r757 FAN UNIT TAG FAN UNIT MODEL # BLOWER HOUSING CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS,) S❑NES NO, 3 Al-G10 G10 Al 2160 0,500 806 1,000 3 208 33 236 15,6 4 A1-1510 610 Al 2700 0 500 899 1,500 3 208 4,7 241 19,4 FA AT nPTTnN.C' FAN UNIT NO. TAG ❑PTION (Qty. - Descr,) 1 - Grease Box _ 1 1 - Miami Dade Certification, 1 - Grease Box -_ 1 - Miami Dade Certification, 1 - Miami Dade Certification. 1 - Miami Dade Certification. 2 3 4 rTTRR NO, 0 N WEIGHT ITEM SIZE 1 # 1 53 LBS Curb 26.500'W x 26,500'L x 24,000"H Vented Hinged 16 Gauge 2 # 2 71 LBS Curb 31,500'W x 31,500'L- x 24,000"H Vented 16 Gauge 3 # 3 48 LBS Curb 21.000'W x 21.000'L x 12,000'H 16 Gauge 4 # 4 48 LBS Curb 21,000"W x 21.000'L x 12,000'H 16 Gauge EXHAUST FANS SIZED BASED ON ESTIMATE OF PANT LEG DUCT & 2 90 DEGREE ELBOWS PER KITCHEr�! HOOD, DUCT SIZE AT 1500 FPM, CONTACT CAPTIVEAIRE TO C❑NFIRM EXHAUST FAN SIZING, 33 3/8 2- FIRE SYSTEM HOOD HANGING ZICAL SWITCHES L # QUANTITY PIPING WGHT YES 893 LBS 1 Light 919 1111 1 Fan YES LBS DETECTION AGENT LINE DUCT PROTECTION NOZZLE DETECTORS SYSTEM CONTROL AUTOMAN J REMOTE MANUAL WITH AGENT TANK ENCLOSED PULL STATION 38 7/H -�N EXHAUST RISER ON HOOD AND FAN (BY OTHERS) 29 1/2 PLENUM PROTECTION NOZZLE APPLIANCE PROTECTION NOZZLE TYPICAL FIRE SUPPRESSION SYSTEM LAYOUT WITH REMOTE MOUNTED AUTOMAN EATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UI-705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300'17 (149'0 GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EX14AUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300'17 (149'C> UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'0 FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, UnLuba GREASE BOX MIAMI DADE CERTIFICATION. F U.L. Listed Incandescent Light Fixture -High Temp Assembly �-- 45 3/4' - 24' I- 46' 46' 15' 3,00'Nom✓15' 3,00'OD 15-6.00' Overall Length FLAN VIEW — Hood #1 (45) 15' 3.00" LONG 6030ND-2—PSP—F NOTE, Additional hanging angles provided Por hoods 12' and longer. BALANCE DAMPERS HANGING ANGLE 20' SS BAFFLE WITH HANDLES AND HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIMCE WITH LOCAL CODE REOWREMENTS. GREASE DRAIN WITH REMOVABLE CUP RIGHT VERTICAL END PANEL WITH ADJUSTABLE LEGS �.IX , * + - . PAN #3 Al-G10 - SUPPLY PAN FAN #4 Al-610 - SUPPLY PAN 1. UNTEMPERED SUPPLY UNIT WITH 10' BLOWER IN SIZE #1 HOUSING 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. MIAMI BADE IMPACT AND WIND LOAD CERTIFICATION - MIAMI DADE COUNTY PRODUCT CONTROL APPROVED, FLORIDA BUILDING CODE APPROVAL. CURBS MUST BE 16 GAUGE ALUMINIZED, MPU CURB CLIPS ORDERED SEPARATELY. BL❑WET n.n� THESE PLEI S gNU ALL PROPOSED WORK 13 ARESUDJECT TO A14Y CORRECTIONS REQUIRED V FIELD INSPECTORSTHAT 490 SAY BE NECESSARY IN ORDER TO 3 CgAPLY WITH ALL APPLICABLE CODES. VENTED CURB 6 GAUGE :TEEL INSTRUCTION ter, wE ROOF OPENING 24 DIMENSIONS 24 LIFTING LUG 3 12' EQUIPMENT CURB k ROOF OPENING 2' SMALLER THAN CURB DIMENSION. 8 1/4" 29 3/4' 32 1/8' AIRFL❑W _SERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ. ' INCANDESCENT LIGHT FIXTURE -HIGH TEMP " ' "ICLUDES CLEAR THERMAL AND TAINT GLOBE (L55 FIXTURE) CAPPER IMV HIGH D OPTIONS TABLE) dG PLATES RISER WITH DAMPER 5% OPEN STAINLESS EEL PERFORATED PANEL GM. TYP, 'j- X� Design Group, Inc, Jacksonville, Florida 904-543-7670 www.jaxdesigngroup.com Foodservice Consulting & Design m z o o it V) w 0 W � w Q 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUSUCAT10N THEREOF IS EXPRESSLY LIMITED TO SUCH USE. W r� nV lJ W (D o W o 0 I 11 U U o� Q� U nl W v � 0n �D V J 0 Q �f L BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 W'ebsite: www:bashamlucas.com L.ic Nos. AA26000586 LC26000508 EXHAUST 8c FIRE SUPPRESSION SYSTEMS N.T.S. DRAWN BY JZ CHECKED BY GV DATE 3- 6-2014 JOB NO. -- — 13-40 SHEET NO. 3' T- 9 -i9. 10, 10° O✓� �— 16' �-- 16, O 54' U.L. Listed Incandescent Light Fixture -High Temp Assembly Utility Cabinet ® 28" 14' 12`—'I -- 71 40 1/2' 81° — 22 112. 43' --i— —_ 43' e� 12' 13, 6,00'Nom./13' 6.00'OD 43 3/8 14'-6,00' Nverall Length �{ 40 1/2' 43' — I-- 22 1/2' PLAN VIEW — H )Od #2 125) 13' 6.00" LQ_NG 5430ND-2—PSP—F NOTE, Addltional hanging angles provided for hoods 12' and longer. FEATURES - ROOF MIUJNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SiIUND AND AIR CERTIFIED - WIRING IROM MOTOR TO DISCONNECT SWITCH - WEATHI.RPROOF DISCONNECT - HIGH HFAT OPERATION 300-F (149'C) - GREASE CLASSIFICATION TESTING 37 1/2 NORMAL TEMPERATURE TEST 30 5/9 EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE E/HAUSTING AIR AT 300'F (149'0 UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE ❑PERATION, ABNORMAL FLARE --UP TEST EXHAUST FAN MUS1 OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS 2 J AT 600'F (316'0 FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING 23 7/8 DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. �_N EXHAUST `RISER ON HOOD AND FAN (BY OTHERS) OPTIONS GREASE BOX MIAMI DADE CERTIFICATION. c BALANCE DAMPERS HANGING ANGLE 20' CAPTRATE SOLE FILTER WITH HOOK 3' INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TE ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITI LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP SECTION V E W — MODEL a430ND-2—BFP—F HOOD — #2 125 FAN #3 Al-610 - SUPPLY PAN PAI"� #4 Al-G10 - SUPPLY PAN 1. UNTEMPERED SUPPLY UNIT WITH 10' BLOWER IN SIZE #1 HOUSING 2, INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. MIAMI DADE IMPACT AND WIND LOAD CERTIFICATION - MIAMI DADE COUNTY PRODUCT i'ONTROL APPROVED. FLORIDA BUILDING CODE APPROVAL. CURBS MUST BE 16 GAUGE ALUMINIZED, MPU CURB CLIPS ORDERED SEPARATELY, LIFTING LUG 3 12' EQUIPMENT CURB �--- 21' -� ROOF OPENING 2' SMALLER THAN CURB DIMENSION. VENTED CURB 6 GAUGE TEEL :❑NSTRUCTI❑N .GE ROOF ❑PENING 28 DIMENSIONS 28 8 1/4' BL❑WEi' me r ,...�- 29 3/4' 32 1/8' AIRFLOW `SERVICE DISCONNECT SWITCH BLOWER/MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ. ' D INCANDESCENY LIGHT FIXTURE -HIGH TEMP "ICLUDES CLEAR THERMAL AND TANT GLOBE (L55 FIXTURE) r/RAPPER 12,00' HIGH 30D OPTIONS TABLE) PLATES ;ER WITH MPER OPEN STAINLESS PERFORATED PANEL OM. TYP. DUCT PR❑TECTI❑N NOZZLE DETECTOR REMOTE MANUAL PULL STATI❑N REMOVABLE STAINLESS -' STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY PLENUM PR❑TECTI❑N NOZZLE APPLIANCE PR❑TECTI❑N NOZZLE "�- ❑PTI❑NAL PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS, 3-PHASE CONTACTORS AND OVERLOADS FAN AND LIGHT CIF APPLICABLE) CONTROL PANEL TYPICAL ANSUL R- 9 02 SYSTEM LAYOUT Item 55, Woodstone oven model WS-BL-4343-RFG, This gas -fired oven is suitable for venting through a Wood Stone exhaust hood or one constructed in accordance with all relevant local and national codes. Alternatively, the oven iiay be vented using a direct connection to (> power ventilated, grease duct rated, buRding heating appliance chimney, Item 56, Woodstone over, mounted exhaust hood model SG-BDL-0-'� S. 42,5" wide x 27" high x 33" deep, 625 cfm, 7" x 7" duct, ,E30" sp, Exhaust fan Woodstone model WS-GSV-012, 120/60/1, 1.4A Items listed above to b(, provided by FSEC, Fire suppression is part of item 25, by Fire Suppression System Contractor, All ductwork, roof curb and installation Is by CiC/Mechanical Con tractor WS-BL-4343 Item 135, Woodstone oven model WS-MS-4-RFG--IR, This gas -fired oven is suitable for venting through a Wood Stone exhaust hood or one constructed in accordance with all relevant local( and national codes. Alternatively, the oven may be vhnted using a dlirect connection to a power ventilated, grease duct rated, building heating appliance chimney, Item 136, Woodstone oven mounted exhaust hood model SG-BDL-O-WS-30C, 30" wide x 24" high x 37" deep, 450 cfm, 6" x 6" duct, ,80" sp. Exhaust fan Woodstone model WS-GSV-250, 120/'60/1, 2.9A Items listed above to be provided by FSEC. Fire suppression is part of item 132, by Fire Suppression System Contractor, 41 All ductwork, installation LJ�'� roof curb and Is by GC/Mechanical Contractor y -IRE � �JJLi gLL PPOPOSED �111"i' I? 14hly CORR� LAIC E ' U RED SY FIE INSPE i� AY BE *CES3Aay 1i11 OR ® T t COM[)LY WITH ALL ApPLICQpLE C ems. Design Group, Inc. Jacksonville, Florida 904-543-7670 www.jaxdesigngroup.com Foodservice Consulting & Design ENEMIES THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. L_ Cn W n l O v J n 0 (_0 � V J _J rn U 0 n ° PLANNING -ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVIL LE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www: bash am lucas. corn Lic. Nos_: AA26000586 LC26000508 EXHAUST 8c FIRE SUPPRESSION SYSTEMS N.T.S. DRAWN BY JZ CHECKED BY GV DATE 2h-2014 JOB NO. 1 3-40 SHEET NO. 3 JOB NO MODEL NUMBER DRAM BY SO*MADC TYPE DESCRIPTION OF ❑PERATI❑N: 1965057 DCV -1111 INSTALL Demand Control Ventilation, s/ 1 Exhaust Fun, 1 Supply Fan, Exhaust on In Fire, Lights out In Fire, Fans modulate DATE DWG NO based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperoture sensor shipped loose JOB NAME PGA Clubhouse at the Reserve for field Installntlon. 2/4/2014 ECP #1-1 t 2 BREAKER PANEL TO HOOD CONTROL PANEL Responsibility, Electrician 3 BREAKER PANEL HOOD PAI 4 BREAKER 1PH Hot 120 V - ___ Neutral 15 A Ground CONTROL POWER, D❑ NOT WIRE 5 TO SHUNT TRIP BREAKER, 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER 3PH -- _ LINE L1 208 V LINE L2 _ 7 15 AMP -_ LINE Ground _ EXH-1 SM-1 8 WIRE TO VFD QUICK CONNECTOR IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY,! IF 1 PH 120 VAC INPUT, USE L1 & N ONLY. LINE 9 BREAKER 3PH 208 V LINE 15 AMP ---- - __ LINE - 10 - ------Ground SUP-3 SM-2 - WIRE TO VFD QUICK CONNECTOR 11 IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY. IF 1 PH 120 VAC INPUT, USE L1 & N ONLY, L- 12 HOOD CONTROL PANEL TO FANS / MUA 13 Responsibility, Electrician HOOD PANEL FANS 14 FAN, 01 EXH-1 Load Wiring LOAD LEG I - - -- ---Dio IFLA,62 LOAD LEG 2 c 1 1 4/o IM'. 2.000 LOAD LEG 3 15 RE WIRE TO o VOLT, 208 V VFD QUICKCCNDa GROUND CONNECTOR WIRE TO 16 MUST HAVE ITS OWN CONDUIT DISCONNECT DO NOT SHARE CONDUITI 17 Load Wiring FAN 03 LOAD LEG 1 A BLACK SUP-3 / FLA,3.3 LOAD LEG 2 BLACK S M-2 p HP, 1000 IVOLT,208 V LOAD LEG 3 BLACK — WIRE TO `, W 120V_H13T RED 18 VFD QUICK o 120V NEUTRAL A� Jyp_-. WHITE_ CONNECTOR _ V ATt- __. GROUND-®_--_-fiREEN/_ -YV wlTy�_ 19 �3llYlt=d I MUST HAVE ITS OWN METAL CONDUIT, WIRE TO PROVIDED 20 CONDUIT DROP, MAKE UP AIR ON PCB REMOVE JUMPER IN MUA #1 21 DAMPER L A -i�cj PROVING Fr= D 00 - INTERLOCK LOW VOLTAGE CONNECTION FOR TERMINAL NAMES 22 DAMPER INTERLOCK. SHOULD HAVE CONTINUITY WHEN DAMPER DO PAT APPLY IF MUA BY OTHERS - IS PROVEN OPEN, - NOT REQUIRED FOR ALL UNITS, 23 SEE MAKE-UP AIR SCHEMATIC, 24 HOOD CONTROL PANEL TO ACCESSORY ITEMS Responsibility, Electrician MICRDSWITCH 1 n4 N❑ OFF FIRE SYSTEM A Ra MICRDSWITCH WIRE Cl TD COMMON (1)• WIRE ARI TONORMALLY CLOSED (2)• C1 TO ARI SHOULD HAVE MS-1 4-NO OFF CONTINUITY WHEN ARMED, 11C NC 7�!_ IF MORE THAN ONE MS-2 4,NO SAP FIRE SYSTEM, WIRE E-- 1 NC IN SERIES AS SHOWN HOOD PANEL I� I WIRE DIRECTLY TO CONTROL BOARD HMI TO `14 CAT-5 CONNECTION u l REMOTE MOUNTED PLACE END OF LINE PLUG IN EMPTY JACK PN: EOL120A E❑ 20A 2 SWITCHES • HOOD LIGHTS 1 HOOD LIGHTS WIRE TO J-BOX ON TOP OF HOOD TO L WIRE TO CONTROL BOARD, 1 ROOM TEMP ITCHEN TEMP SENSOR MOUNTED IN ROOM AWAY SENSOR FROM HEAT SOURCES, SEE MANUAL ­ "..., WIRE TU CUNTROL BOARD, HUUD 1 DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT RISER 1 SENSOR MOUNTED IN EXHAUST DUCT RISER 2 THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS SIGNAL FDR N1 NEUTRAL FROM SHUNT CO] EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. HOOD PANEL COMM[ --- ---- NORMALLY OPE SPARE FIRE SPARE CONTACTS USED WHEN FIRE SYSTEM DRY SYSTEM DISCHARGES TO DISABLE CONTACT EQUIPMENT OR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM) COIL HOOD PANEL DRY CONTACT ON/OFF WITH SUPPLY FAN EMS SPEED -10V ❑UTPL -1UV UUIPU SPARE CONTACTS WILL MAKE COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. WIRE TO ECPM03 TERMINALS. CONFIGURABLE OUTPUT, SEE ECPM03 OWNERS MANUAL, WIRE TO VFD TERMINA STRIP. PROPORTIONAL TO FRE(1EUENCY. SEE VFD OWNERS MANUAL, TO BMS TO BMS JOB NO MODEL NUMBER WAWN BY SCHEMATIC TYPE DESCRIPTION OF ❑PERATIONi 1965057 DCV -1111 INSTALL Demand Control Ventilation, e/ 1 Exhaust Fan, 1 Supply Fan, Exhaust an In Fire, Lights out In Fire, Fans modulate DAZE DWG NO based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperature sensor shipped loose JOB NAME PGA Clubhouse at the Reserve for field Installation. 2/4/2014 ECP #2-1 1 2 BREAKER PANEL TO HOOD CONTROL PANEL Responsibility, Electrlclan 3 BREAKER PANEL HOOD PAI 4 BREAKER 1PH Hot Hlc 120 V Neutral N1 C 15 A - __ Ground _ CONTROL POWER, D❑ NOT WIRE 9 TO SHUNT TRIP BREAKER, 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER, SWITCH #1 8 BREAKER 3PH LINE L1 208 V LINE 2 7 15 AMP LINE Ground EXH-2 SM-1 8 WIRE TO VFD QUICK CONNECTOR IF 1 PH 240 VAC INPUT, USE L1 & L2 ONLY. IF 1 PH 120 VAC INPUT, USE L1 & N ONLY, a BREAKER 3PH LINE 208 V LINE FL _5 15 AMP LINE L 10 Ground SUP-4 SM-2 WIRE TO VFD QUICK CONNECTOR 11 IF 1 PH 0 VAC INPUT, USE LI & L2 ONLY. IF 1 PH 120 VAC INPUT, USE L1 & N ONLY. 12 12 . HOOD CONTROL PANEL TO FANS / MUA 13 Responsibilityi Electrician HOOD PANEL FANS 14 Load Wiring LOAD LEG 1 FAN, 02 EXH-2 FLA-9.5 LOAD LEG 2 15 SM-1 WIRE TO io o W 3.000 VOLT.208 V LOAD LEG 3 GROUND VFD QUICK - { MUST HAVE ITS OWN CONDUIT 16 CONNECTOR WIRE TO I DISCONNECT D❑ NOT SHARE CONDUITI 17 Load Wiring SM-� FAN 04 LOAD LEG 1 BLACK SUP-4 o o% FL HP' L500 IVOLT-208 V - LOAD LEG 2 _- ® BLACK - 18 WIRE TO VFD QUICK LOAD LEG 3 _� BLACK o 120V HOT RED 1201 NEUTRAL WHITE CONNECTOR All GROUND GREEN 19 II MUST HAVE ITS OWN METAL CONDUIT, WIRE TO PROVIDED 20 CONDUIT DROP. MAKE UP AIR ON PCB REMOVE JUMPER IN MUA #1 21 DAMPER - PROVING `�, ---------- 22 INTERLOCK LOW VOLTAGE CONNECTION FOR DAMPER INTERLOCK. SHOULD HAVE CONTINUITY WHEN DAMPER TERMINAL NAP DO NDT APPi IF MUA BY OTP _ IS PROVEN OPEN, NOT REQUIRED FOR ALL UNITS. 23 SEE MAKE-UP AIR SCHEMATIC• 24 HOOD CONTROL PANEL TO ACCESSORY ITEMS Responsibiiity, Electrician HOOD PANEL COMPONENT MICROS' WITCH 1 HOOD PANEL 4'NO SAP TO --- 1IC FIRE SYSTEM MICRDSWITCH WIRE C1 TO COMMON (1). -1NC WIRE ARI TO NORMALLY CLOSED (2), CI TO ARI SHOULD HAVE MS-1 4,N❑ SAP CONTINUITY WHEN ARMED, 11 NC IF MORE THAN ONE MS-2 4,NO CFF FIRE SYSTEM, WIRE IN SERIES AS SHOWN 17 11C� HOOD PANEL ALL SWITCHES FACTORY WIRED TO a ,CAT-5 CONNECTION HOOD LIGHTS I HOOD LIGHTS GREI ldnn I.i mAy IWIRE TO J-BOX ON TOP OF HOOD __ ILI LUNIKUL BOARD• ROOM TEMP :ITCHEN TEMP SENSOR MOUNTED IN ROOM AWAY SENSOR FROM HEAT SOURCES, SEE MANUAL IU I FACTORY WIRED TEMPERATURE IUCT SENSOR SENSOR, MOUNTED IN EXHAUST DUCT HOOD PANEL TO FACTORY WIRED TEMPERATURE SENSOR, MOUNTED IN EXHAUST DUCT RISER 2 THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS HOOD PANEL ---- - nu -,u onun, emu. SIGNAL FOR NEUTRAL FROM SHUNT CO: EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. HDDD PANEL -- COMMC SPARE FIRE _____ _ NORMALLY ❑PE iYSTEM DRY SPARE CONTACTS USED WHEN FIRE SYSTEM DISCHARGES TO DISABLE CONTACT EQUIPMENT OR PROVIDE SIGNALS, (NOT FOR BUILDING FIRE ALARM) COIL ON/OFF WITH SUPPLY FAN SPARE CONTACTS WILL MAKE COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. EMS SPEED V/ +- + TO BMS 0-10V OUTPUT WIRE TO ECPM03 TERMINALS. ON PCB CONFIGURABLE OUTPUT. (TOTAL) SEE ECPM03 OWNERS MANUAL. VFD ANALOG + 0-lOV OUTPUT - TO BMS I�VFD W�IRETOUNERS tANUAL, STRIP.UENCY,(EACH VFD) F.NT.FrTRTrAT. PArAA('1F.N.4 NO. TAG PACKAGE LOCATION SWITCHES ❑PTION FANS CONTROLLED # L❑CATI❑N "Mount QUANTITY TYPE 0H,P. VOLT FLA 1 DCV-1111 Wall Mount In SS Box Face e 1 Light Smart Controls DCV Exhaust 3 2,000 208 6.2 Hood # 1 _SWWY PP Y 3 1.000 208 3.3 1 Fan 2 DCV-1111 Utility Cabinet Left Utility Cabinet Left 1 Light Smart Controls DCV Exhaust 3 3.000 208 9.5 Hood 2 Supply 3 1,500 208 4.7 1 Fan SENS❑li-"- TYPICAL HOOD CONTROL PANEL INSTALLATION Demand Control Ventilation Hood Control Panel Soecif!cations: • Controls shall be listed by ETL (UL 508A) • The control enclosure shall be NEMA 1 rated and listed for installation inside of the exhaust hood utility cabinet, The control enclosure may be constructed of stainless steel or painted steel, • Temperature probe(s) located in the exhaust duct riser(s) shall be constructed of stainless steel. • A digital thermostat controller shall be provided to activate the hood exhaust fans dynamically based on a +10 degree adjustable offset from the room temperature sensor, This function shall meet the requirements of IMC 507.2.1.1 • A digital thermostat controller shall provide adjustable hysteresis settings to prevent cycling of the fans after the cooking appliances have been turned off and/or the heat in the exhaust system is reduced, • A digital thermostat controller shall provide an adjustable minimum fan run-time setting to prevent fan cycling, • Variable Frequency Drives (VFDs) shall be provided for fans as required. The Hood Control Panel shall modulate the VFDs between a minimum setpoint and a maximum setpolnt on demand. The duct temperature sensor input(s) to the digital thermostat controller shall be the speed reference signal, • The VFD speed range of operation shall be from 0% to 100% for the system, with the actual minimum speed set as required to meet minimum ventilation requirements, • An internal algorithm to the digital thermostat controller shall modulate supply fan VFD speed proportional to all exhaust fans that are located in the same fan group as the supply fan, • The system shall operate In PREP MODE during light cooking load or COOL DOWN MODE when sufficient heat remains underneath the hood system after cooking operations have completed, Operation during either of these periods will disable the supply fans and provide an exhaust fan speed that is equal to the minimum ventilation requirement. • A digital thermostat controller shall disable the supply fan(s), activate the exhaust fan(s), activate the appliance shunt trip, and disable an electric gas valve automatically under the following conditions (as applicable), a. Fire condition detected on a covered hood b. Excessive temperature detected on any duct temperature sensor in the system (250 F adjustable) • A digital thermostat controller shall allow for external BMS fan control via Dry Contact (external control shalt not override fan operation logic as required by code), • An LCD interface shall be provided with the following featuresi a. ❑n/Off push button fan & light switch activation b. Integrated gas valve reset for electronic gas valves (no reset relay required) C. VFD Fault display with audible & visual alarm notification d. Duct temperature sensor failure detection with audible & visual alarm notification e. Mis-wired duct temperature sensor detection with audible & visual alarm notification f, A single low voltage Cat-5 RJ45 wiring connection g. An energy savings indicator that utilizes measured kWh from the VFDs 0 0 O VASH tGA"SRESIET 0 �rAviL OO 0 0 ALATN SIMMS LCS SCREM �MNOI CMIMM VENTILATION WRlfit •IIIMTO :AT-0 CONNECTION IN IEVOM :ONNUITES TO N= CONTROL ORBS IN STANDARD MOUNU ;" JUNCTION SON THESE PL4NS A1VD ALL pACi C�gEC AFIE SUBJECT Tp WORK BEQU"'EO QYFIEL® NSPECTECrf4Af3 NAY BE NECESSARY 6i'Y 0R �� To t CQigPLY VVITH ALL APPUCAnLE Conn. 1 Design Group, Inc. Jacksonville, Florida 904-543-7670 www.jaxdesigngroup.com Foodservice Consulting & Design milli NIEMENI THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. n� nV ,1 W 0 e e � O - }--J U eT U C :D 0 Il� (_0 V / rn +� O L� Q e e In 1 BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamiucas.com Lic. Nos.: AA26000586 LC26000508 EXHAUST & FIRE SUPPRESSION SYSTEMS N.T.S. DRAWN BY Jz CHECKED BY GV DATE 3-26-2014 JOB NO. 13-40 SHEET NO. FS 5 F 0 0 D S E R V I C E E Q U I P M E N T S C H E D U L E ITEM QTTF_ DESCRIPTION MANUFACTURER MODEL NUMBER ELECTRICAL. PLUMBING REMARKS L� Q .12 J W Y D_ D__] co H O W Cn = d H U W - 0 U _ a- W J ¢ Q � WATER WASTE ; L1_ Q 0 O U O = H U W 0 H- U W Z L� Q W N m _ :DW I- m Y 1 1 WALK --IN COOLER/FREEZER THERMO-KOOL 108 5.0 120 1 1 X FOR COOLER LIGHTS 1 108 5.0 120 1 X FOR FREEZER DOOR HEATER. WIRE SEPERATELY FROM LIGHTS & CONNECT AT START-UP ONLY 2 1 COOLER EVAPORATOR COIL THERMO-KOOL TKM-1300 108 1.8 120 1 X 3/4 CONDENSATE CONDENSATE DRAIN TO OUTSIDE BY COOLER INSTALLER 2 3 1 COOLER REMOTE. C/U THERMO-KOOL MOH015X63 1 36 9.4 1.5 208 3 X _RUN VERIFY LOCATION ON ARCH/MECH PLANS 3 4 1 BEER COOLER EVAPORATOR COIL THERMO-KOOL TKM-0900 108 1.8 120 1 X 3/4 CONDENSATE CONDENSATE DRAIN RUN TO OUTSIDE BY COOLER INSTALLER 4 5 1 BEER COOLER REMOTE C U THERMO-KOOL MOH01OX63 36 5.8 1.0 208 3 X VERIFY LOCATION ON ARCH/MECH PLANS 5 6 1 FREEZER EVAPORATOR COIL THERMO-KOOL TKL-0751 108 8.8 1.9 208 1 X 3/4 CONDENSATE CONDENSATE DRAIN RUN TO OUTSIDE BY COOLER INSTALLER 6 7 1 FREEZER REMOTE C U THERMO-KOOL MOH019L63 1 36 8.9 2.0 208 3 X VERIFY LOCATION ON ARCH/MECH PLANS 7 8 2 DUNNAGE RACKS NEW AGE 2014 8 9 1 BEER KEG RACK - NEW AGE 1289 g 10 1 FLOOR MIXER HOBART HL400 16 5.6 1.5 208 3 X GC/EC TO PROVIDE AND INSTALL CORD AND PLUG lo- ll 1 LOT MOBILE STORAGE_SHELVING UNITS METRO METROSEAL 3 i 11 12 12 2 MOBILE PAN RACKS NEW AGE 4337 13 1 LOT MOBILE STORAGE SHELVING UNITS METRO METROSEAL 3 VENDOR TO PROVIDE & INSTALL SYSTEM & LINES 13 14 14 1 LOT SODA SY`_)-FEM BY VENDOR 16 7.5 E 120 1 X 16 1/2 15 1 S/S MOBILE MIXER STAND FLORIDA STAINLESS 1 15 16 1 BENCH MIXER EXISTING 48 12.5 120 1 X 16 17 1 SLICER _ _ EXISTING _ POWER SUPPLY FROM FLOOR MOUNTED OUTLETS, SEE ITEM 36 17 18 1 FOOD PROCESSOR EXISTING 48 12.5 120 1 X 18 19 1 S/S PREP TABLE W/SINK FLORIDA STAINLESS _ 16 1/2 1/2 19 20 OPEN NUMBER _ 20 21 11 DISPOSER S S WALL -SHELF WATER HEATER_ SALVAJOR 150-SA-6-MRSS 12 6.2 1.5 208 3 X 12 1/2 2 21 22 1 FLORIDA STAINLESS WALLBACKING, IF REQUIRED, TO BE PROVIDED & INSTALLED BY GC 22 23 23 1 EXISTING 24 1 AIR DOOR EXISTING 24 25 1 LOT FIRE SUPPRESSION SYSTEM EXISTING TO BE RENOVATED EXIST SYSTEM TO BE REMOVED & REINSTALLED, FIRE EQPT SVCS, FT PIERCE. SEE WRITTEN SPECS 25 26 11 S/S CLEAN DISHTABLE _ FLORIDA STAINLESS - WALLBACKING TO BE PROVIDED &INSTALLED BY GC 26 27 27_ 1 S/S WALLSHELF ______ FLORIDA STAINLESS 28 3 S/S FLOOR TROUGHS _ ADVANCE FFTG-1848 -7 4 3 LOCATIONS 28 29 1 LOW TEMP CONVEYOR DISHWASHER CMA EST-44 66 46.0 208 3 X 12 1/2 2 FLOOR SINK HOT WATER SUPPLY FROM BOOSTER HEATER, ITEM 30 RUN OUTLET ON BOOSTER HEATER TO INLET ON DISHMACHINE, ITEM 29 29 30 30 1 ELEC HOT WATI_R BOOSTER HEATER HATCO C-15 16 41.7 15.0 208 3 X 16 3/4 31 1 DISPOSER SALVAJOR 200-SA-6-MRSS 12 6.6 2.0 208 3 X 12 1/2 2 - 31 32 1 S/S SOILED DISHTABLE - -- - FLORIDA STAINLESS 16 1/2 1/2 _ 32 33 1 HOSE REEL T&S B-1433 1 152 1/2 1/2 1 WALLBACKING, IF REQUIRED, TO BE PROVIDED & INSTALLED BY GC 33 34 2 NEW WALL MOUNTED HANDSINKS� ADVANCE 7-PS-64 16 1/2 1/2 1 1/2 - 2 LOCATIONS. STUB OUT WASTE AT 24 AFF 34 35 11 MOBILE HEATED CABINET S/S MOBILE PREP TABLE MOBILE CART EXISTING 16 1 2.0 120 1 X _ VERIFY PLUG TYPE 35 36 1 FLORIDA STAINLESS 6 2@20.0 A EA 120 1 X - 2 LOCATIONS. WATERPROOF TYPE FLOOR MOUNTED OUTLETS FOR TABLETOP EQUIPMENT 36 37 37 1 CAMBRO BC2354S110 38 4 INGREDIENT BINS CAMBRO IBS20148 38 39 1 S S MOBILE PRE-P TABLE FLORIDA STAINLESS ------ 39 40 11 HANDSINK EXISTING 40 41 OPEN NUMBER 12 3 4 21 _000 LP GAS 41 42 1 GAS RANGE W/OVEN VULCAN 36S-6B THIS ITEM SUPPLIED W FLEXIBLE GAS CONNECTOR GC EC TO SUPPLY AND INSTALL CORD AND PLUG 42 43 1 ELECTRIC ROTISSERIE OVEN ALTO-SHAAM AR-7E 36 33.0 8.3 208 3 X 44 1 ELECTRIC COMBINATION OVEN _ ALTO-SHAAM CTP10-20E 36 98.5 30.9 208 3 X 36 3/4 1 1/2 FLOOR SINK DEDICATED CIRCUIT REQ'D. DO NOT CONNECT TO GFI OUTLET 44 2 CW INLETS ON OVEN, MANIFOLD SUPPLY & INSTALL SUPPLIED FILTER IN 1 LINE 45 1 LOT EXHAUST SYSTEM W/MAKE-UP AIR CAPTIVE-AIRE _ 603OND-2-PSP--F 108 2.5 120 1 X FOR HOOD LIGHTS 45 1 EXHAUST FAN _ CAPTIVE-AIRE _ NCA18HPFA 108 6.2 1 1.5 208 3 X INTERCONNECT CONTROL PANEL ON HOOD WITH FAN ON ROOF 1 MAKE-UP AIR FAN CAPTIVE-AIRE Al-G10 108 1 3.3 1.0 208 3 X INTERCONNECT CONTROL PANEL ON HOOD WITH FAN ON ROOF 46 1 LOT S/S WALL FLASHING _ CAPTIVE-AIRE 120 1 X -7 16 16 1/2 1/2 1/2 1/2 4 1 1/2 FLOOR SINK 12 1/2 104,000 LP GAS 46 47 47 11 FLOOR TR'UGH ,ADVANCE FFTG-1830 48 1 _ 3 COMPAPTMEAT SINK EXISTING EXTEND DRAIN LINE TO EXISTING FLOOR SINK 48 49 1 S/S WALE ',HELF EXISTING WALLBACKING, IF REQUIRED, TO BE PROVIDED & INSTALLED BY GC GC/EC TO PROVIDE & INSTALL CORD & PLUG. FLEX GAS CONNECTOR PROVIDED 49 50 50 1 GAS TILT SKILLET GROEN BPM-30G 16 1.0 51 OPEN NUMBER _ 51 52 OPEN NUMBER 52 53 OPEN NUMBER - 53 54 OPEN NUMBER 54 55 1 GAS PIZZA OVEN WOODSTONE WS-BL-4343-RFG 44/16 2.0 120 1 X 12 3/4 68,000 LP GAS PROVIDE 1 DOUBLE POLE WALL SWITCH, RUN TO OVEN AND EXHAUST FAN, ITEM 56 55 56 1 LOT PIZZA OVEN VENTILATION_ WOODSTONE SGBDLOWS/WSGSV012 44 1.4 120 1 X PROVIDE 1 DOUBLE POLE WALL SWITCH, RUN TO OVEN, ITEM 55, AND EXHAUST FAN 56 57 57 1 S/S MOBILE WORKTABLE FLORIDA STAINLESS 58 1 LOTI EXHAUST 'SYSTEM & WALL FLASHING - - - EXISTING 58 59 1 GAS SALAMANDER BROILER `VULCAN 36RB 50 000 LP GAS INTERPIPED COMMON GAS CONNECTION W/ITEM 61 59 60 OPEN NUMBER 60 61 1 GAS RANGE W/DUAL OVENS `VULCAN 60SS-10B 16 15.0 120 1 X 12 1 1/2 358,000 LP GAS COMMON GAS CONNECTION FOR ITEMS 59 & 61. WITH FLEX GAS CONNECTOR 61 62 1 REF CHEFS BASE RANDELL 20072SC-C4 16 7.4 .33 120 1 X THIS ITEM SUPPLIED W/FLEXIBLE GAS CONNECTOR 62 63 63 1 GAS CHARBROILER MAGIKITCH'N APL-RMB-636 12 3 105,000 LP GAS 64 1 GAS GRIDDLE `VULCAN MSA36 12 3/4 81,000 LP GAS THIS ITEM SUPPLIED W/FLEXIBLE GAS CONNECTOR 64 65 1 1 GAS DUAL. FRYERS W/FILTER PITCO 2-SG14S/FD 16 7.0 1 120 120 1 1 X X 12 1 220,000 LP GAS THIS ITEM SUPPLIED W/FLEXIBLE GAS CONNECTOR POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 65 66 66 1 REACH -IN FREEZER RANDELL 2010E 9.3 50 67 1 FIRE EXTIH(.3UISHER BY GC 208 208 1 1 X NEMA 6-15P 67 68 1 ROTARY 10ASTEIR HATCO TQ-400 1 10.7 2.2 POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 68 69 69 2 HEAT LAMPS HATCO GRAM-60 2@1.7 70 1 S/S CHEF) COUNTER FLORIDA STAINLESS 4 125.0 120-208 1/3 X PRE -WIRED SINGLE POINT CONNECTION W/PANEL BOX 70 71 2 COUNTERTOP SOUP WELLS v VOLLRATH 72021 6.7EA .8 EA 120 1 X POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 DATA LINE REQUIRED. VENDOR ITEM, VERIFY QUANTITIES & LOCATIONS 71 72a 72a 1 POS SYSTEM PRINTER BY VENDOR 2.5 120 1 X X 72b 3 POS SYSTEM PRINTERS BY VENDOR 48 2.5 120 1 X X DATA LINES REQUIRED. VENDOR ITEM, VERIFY QUANTITIES & LOCATIONS 72b 73 74 75 1 1 1 REF SANDWICH UNIT MICROWAVE OVEN _ S/S HANDSINK - RANDELL AMANA FLORIDA STAINLESS 903OK-7 RCS10DSE 9.0 1 13.0 1.5 .33 120 1 120 1 1 1 X X 4 1/2 1/2 1 1/2 HUB DRAIN _ POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 POWER FOR ITEMS 66,68,69,71,72a,73,74,118&119 SUPPLIED THRU CHEFS COUNTER, ITEM 70 73 74 75 76 1 REF PIZZA PREP TABLE RANDELL 8260N 16 9.0 .33 120 1 X 76 77 1 REACH -IN REFRIGERATOR RANDELL 2010 84 6.9 .25 120 1 X 77 78 1 S/S BEVERAGE TABLE FLORIDA STAINLESS 48 15.0 120 1 X 78 79 1 S'S DOUBLE WALLSHELF FLORIDA STAINLESS WALLBACKING, IF REQUIRED, TO BE PROVIDED & INSTALLED BY GC 79 80 1 COFFEE BREWER BY VENDOR 48 15.0 120 1 X 44 1/2 80 81 2 ICE TEA DISPENSERS BY VENDOR 81 82 1 LOT POS SYSTEM CASH REGISTERS BY VENDOR 1 48 5.0 120 X X DATA LINES REQUIRED. VENDOR ITEM, VERIFY QUANTITIES & LOCATIONS 82 83 1 PASS-THRU ICE BIN PERLICK SS241C10 1 1/2 FLOOR SINK RUN TO EXISTING FLOOR SINK LOCATED AT ITEM 111 83 84 1 HAND SINK PERLICK TS12HS 12 1/2 1 /2 1 1/2 FLOOR SINK RUN TO EXISTING FLOOR SINK LOCATED AT ITEM 111 84 85 12 MOBILE GLASS RACKS EXISTING 85 86 1 MOBILE DISH DOLLY METRO PCD11A _ 86 87 2 COFFEE BREWERS BY VENDOR 1 48 15.0 120 1 Ix 144 1 2 2 LOCATIONS 87 88 2 S/S WALLSHELVES FLORIDA STAINLESS WALLBACKING, IF REQUIRED, TO BE PROVIDED & INSTALLED BY GC 88 89 1 S/S BEVERAGE TABLE FLORIDA STAINLESS 48 15.0 120 1 X 89 90 91 1 1 2 SODA DISPENSER W/ICE BIN ICE TEA DISPENSERS BY VENDOR BY VENDOR 16 12.5 120 1 X 16 1/2 1 1 1/2 HUB DRAIN gp 91 92 92 1 S/S BEVERAGE TABLE FLORIDA STAINLESS 48 15.0 120 120 120 _ 1 1 1 X X 1 X 1144 1 2 93 1 ICE TEA BREWER BY VENDOR 48 15.0 93 94 1 REACH -IN REF _ RANDELL 2010 84 6.9 5 94 95 1 LOT SLIM JIM TRASH CANS- BY OWNER rhESIE PWAIS ARE A d -4M) ALL PR®PpS �EQUIR�� nyPdE®®i� C®RR�� ARK coMpLyeE�ESsAA�d,�E�ST b"ydr�/ALL APPLICA LE TO ©DES. r .," IT _Z�S_ -->': Design Group. Inc. Jackson illc. Florida 904-543-7670 w Nc Ni . jaxdesigngroup. com Foodsen ice Consulting & Design soni THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. v s� V1 PLANNING -ARCHITECTURE FANDSCAPE 7645 GATE PARKWAY, #201 JA.CKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000580 LC26000508 UTILITY CONNECTION SCHEDULE DRAWN BY JZ CHECKED BY GV DATE 3-- -22014 JOB NO. -40 SHEET NO. F 0 0 D S E R V I C E E Q U I P NI E N T S C H E D U L E ITEM QTY DESCRIP 1 96 2 LIQUOR STORAGE_ 97 1 MOP SINK 98 1 STORAGE SHELF/ 99 1 CHEMICAL STORA 100 1 HANDSINK 101 1 LOT DRY STORAGE SI 102 1 ICE MACHINE 103 1 FUTURE HANDSI 104 1 FUTURE SODA D 105 1 (FUTURE) S/S W1 106 1 LOT FUTURE _SODA__`. 107 1 LOT SOLID SURFACE F 108 1 UNDERCOUNTER 1 109 1 DRAFT BEER TAI' 110 2 BANQUET CARTS-- k 111 1 HANDSINK 112 1 BOTTLE COOLER 113 1 3 COMP BAR SIN 114 1 BLENDER STATIOr 115 1 ICE BIN W/COLS) 116 1 BOTTLE COOLER 117 1 TIME CLOCK 118 1 CHEFS LINE BRE< 119 1 CHEFS LINE SALT 120 2 (FUTURE) STORM 121 2 STORAGE SHELVI' 122 1 ROLL -IN REFRIGI_ 123 1 REACH -IN FREE/ 124 1 LOT S/S WALL FLASH 125 1 LOT EXHAUST SYSTEM 1 EXHAUST FAN 1 MAKE-UP AIR FA 126 1 GAS DUAL FRYEF', 127 1 GAS SALAMANDFI 128 1 GAS RANGE W/C�( 129 1 GAS CHARBROILL 130 1 REF CHEF'S BASE 131 1 GAS GRIDDLE _ 132 1 LOT FIRE SUPPRESSIC_ 133 1 REF PIZZA PREP 134 1 S/S WALLSHELF 135 1 GAS PIZZA OVEN 136 1 LOT PIZZA OVEN VEH 137 3 HANDSINKS 138 1 REF SANDWICH l) 139 1 S S MOBILE WOES 140 2 COUNTERTOP SGI 141 OPEN NUMBER_ 142 1 WORKTOP REF 143 1 S/S DOUBLE WAS 144 11 S/S DOUBLE WAI 145 1 3 COMPARTMEN-i 146 1 MILLWORK SERVIC 147 1 MILLWORK SERVIC 148 1 FIRE EXTINGUISHE 149 11 ELECTRIC HOT WANE 150 1 S/S GLASS RACE' 151 1 S/S SOILED DISH 152 1 DISPOSER 153 1 LOW TEMP CONVE 154 1 S/S CLEAN DISF{_ 155 1 S/S WALLSHELF 156 1 LOT SODA SYSTEM 157 1 S/S FLOOR TROT J 158 1 ICE MACHINE, BIf l 159 1 SODA DISPENSEF< 160 1 HOSE REEL 161 1 S S DOUBLE WAL. 162 11 S/S BEVERAGE T 163 2 ICE TEA DISPEN I. 164 1 ICE TEA BREWER 165 1 WORKTOP REFRIGI 166 2 COFFEE BREWER 167 1 MOP SINK _ 168 1 STORAGE SHELF/I 169 OPEN NUMBER 170 OPEN NUMBER 171 OPEN NUMBER 172 1 HANDSINK 173 1 ICEBIN W/COLD P 174 OPEN NUMBER _ 175 1 WINE CHILLER 176 1 BACKBAR COOLED 177 1 GLASS CHILLER 178 1 DRAFT BEER COO[ 179 1 1 STORAGE CABINS-f 180 1 HOT WATER BOOS 181 1 IGLASSWASHER 182 1 DUMP SINK/STORE 183 1 MILLWORK CENTER 184 1 MILLWORK SERVICE 185 1 POPCORN MAKER 186 1 UNDERCOUNTER I� 187 1 COFFEE BREWER 188 1 HOT DOG ROLLER_ 189 1 BUN WARMER 190 OPEN NUMBER THESE PLANS AND ALL ARE PR®POSED IIVOAK SUBJECT TO ANY CORRECTIONS REQUIRED RY FIELD INSPECT�jAS THAT WAY BE AIECESSgRY IW ®pt)ER ib COMPLY WITH ALL APPLICABLE C®pES. I�L . I , �Cory Design Group_ Inc. JacKsom ille. Florida 904-543-7670 -,cNexi .j axdcsigngroup. com Foodsen ice Consulting & Design o I .� 0 In W 0 L.L C^L w Q 0 z I 1 111] THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 1 1 • s • r 1 �1 PLANNING •ARCHITECTIJRE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic Nos. AA26000586 LC26000508 UTI LITY CONNECTION SCHEDULE DRAWN BY ,lz CHECKED BY GV DATE 3-26-2014 ;iOB NO. 1.3-40 SHEET NO. F S �. GC SHALL PROVIDE AND INSTALL WALLBACKING FOR SUPPORT OF WALL MOUNTED EQUIPMENT. SUGGEST 3/4' FIRE TREATED PLYWOOD VERIFY WITH LOCAL CODES, H❑RIZ❑NTAL DIMENSI❑NS AS NOTED. START AT 44' AFF, EXTEND TO 68' AFF UNLESS NOTED DIFFERENTLY, COORDINATE WITH EQUIPMENT SUPPLIER. wVERIFY EXISTING WALL TYPEw GC SHALL PR❑VIDE AND INSTALL WALLBACKING FOR SUPPORT OF WALL MOUNTED EQUIPMENT. SUGGEST 3/4' FIRE TREATED PLYWOOD VERIFY WITH LOCAL CODES, HORIZ❑NTAL DIMENSIONS AS NOTED. START AT 44' AFF, EXTEND TO 68' AFF UNLESS NOTED DIFFERENTLY, C❑ORDINATE WITH EQUIPMENT SUPPLIER, Gf' SHALL PROVIDE AND INSTALL WALLBACKING FOR SUPPORT OF WALL MOUNTED EQUIPMENT. SUGGEST 3/4' FIRE TREATED PLYWOOD VERIFY WITH LOCAL CODES. HORIZONTAL DIMENSIONS AS NOTED. START AT 44' AFF, EXTEND TO 72' AFF FOR DOUBLE WALLSHELVES C❑ORDINATE WITH EQUIPMENT SUPPLIER, I RE S4; ALL � REQUJ'jEE�YC®RR��iL I CID zs'SARY©RS ftriHALLAP/N Mp�* SPEor jE ®AM. WoAl opening le' long Start at 54' Of Extend up 18'. These ClIm's approx, Coordinate w/THD drawings & specs, 1--T _z�' :>� Design Group, Inc. Jacksonville, Florida 904-543-7670 www, jaxciesigngroup.com Foodservice Consulting & Design m G� I ! �7 z O C o_ �^ w �9 LL. CI~ w Q 0 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. n I� W W V I C5 O I n� W U - C5 (a) U 4- O � U O CL Q LD CL BASHAM & LUCAS DESIGN GROUP, INC. PLANNING ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLOREDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 WALLBACKING= AND CRITICAL DIMENSION PLAN SCALE: 1 /4"=1 ' 0" DRAWN BY JZ CHECKED BY GV DATE 3-26-2014 JOB NO. 13-40 SHEET NO. F S -- 4 Item(s) z- Item 157 quantity Fiberglass Non —Skid anti —splash Fiberglass Non —Skid VERIFY RECESS DIMENSIONS WITH MFR'S SHOP DRAWING PROVIDED BY EQPT SUPPLIER POURED FLOOR WITH COVED BASE: ,/BY GC -1 RECESSED FL[ (RED FLOOR T,S. 'AIL 1C _ T 4' CONCRETE OVERLAY BYGC 1 _ T 4' WALK-IN METAL CLAD FACTORY INSU1LATED PANEL 1 SWEEP GASKET POURED FLOOR BY GC 8' RECESS / • / ' GROUT FILLER / / • (by others) / : / FLOOR PANEL RECESSED FLOOR COOLER WITH POUREDFLOOR N,T,S DETAIL lA SWEEP GASKET THRESHOLD HEATER WIRE BOTTOM PLATE SPACER ('AS REQUIRED) --------------- RECESS ' / ./ • / ! GROUT FILLER / / •' (by others) FLOOR PANEL RECESSED FLOOR FREEZER WITH POURED FLOOR N.T.S. DETAIL 1B 4' CONCRETE OVERLAY BY GC 4' WALK-IN (METAL CLAD FACTORY INSU1LATED PANEL = 1 4' CONCRETE OVERLAY BYGC T 4' WALK-IN METAL CLAD FACTORY INSUlLATED PANEL I THL ARE S Q �CT TO ALL PROPOSE R �AV r® FIELD jjV, O ANY RRE QYFIEL� lNSP � �S � coMPL�WINE WCESSQRY��®RS T�1Ai ALt gPpC�Cgp�ER t® ®DES. Design Group, Inc. Jacksonville, Florida 904-543-7670 www, jaxdesigngroup.com Foodservice Consulting & Design THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUF AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBUCATION THEREOF IS EXPRESSLY LIMITED T( SUCH USE. W W V I W 7_ Lam. J `L _ L 0 S LL— T W i 7 - Cv U q-- W n 0 r � �JJ 0 n LD n 0 ?LANNING -ARCHITECTURE i,ANDSCAPE 7645 GATE PARKWAY, #20' JACKSONVILLE, FLORIDA 3225( (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 FLOOR RECESS DETAILS SCALE: 1 /4"=1 '0" DRAWN BY JZ CHECKED BY GV DATE 3-26-201 4 JOB NO. ^� 13-40 SHEET NO. 1-- �. ___ 9 L � P4 • P6 } El On n [If f ice ❑E nrrn•mnrrrr �7, �IIIIIII IIIII � IIIII I P48 UL LLLLLllLL j P48c P48b P28 I I P44 P44b I I I I P14 P21 P21 b P19 P19b P34 !P34b P34C 33 P33b ,,- C= ] e= 1i K= :Ii maj�i P28 4� 3/-3' P42 I I I I 1 12'- P50c P50b P50 P 47 P30 P97 PLUMBING SYMBOL KEY FLOOR SINK WITH HALE GRATE ® HUB DRAIN + HUB DRAIN WITH FUNNEL DIRECT WASTE HOT OR COLD WATER 4 GAS 5.10' %► I�iii►=i �%rtl�=11►-'��I�I�I P28 P31 (- P31 b .,_ P32 C n n rr rr T, rt rT j� IIIIIII III11�1� II �U LLLLWIj 4LII w': 6Ir r n cl, 3 r 1{1�101 4r 6► 0 P55 3/_9r a 7',-9' r P75 P75b P75c 9',- 4' r P103b P103 P103C P104 P104b y 19 PLUMBING ROUGH -IN SCHEDULE P2 3/4" CONDENSATE WASTE, COOLER INSTALLER TO RUN TO OUTSIDE FOR DRIP DRAIN, ITEM :2 P4 3/4" CONDENSATE WASTE, COOLER INSTALLER TO RUN TO OUTSIDE FOR DRIP DRAIN, ITEM 4 P6 3/4" CONDENSATE WASTE, COOLER INSTALLER TO RUN TO OUTSIDE FOR DRIP DRAIN, ITEM 15 P14 1/2" COLD WATER, STUB OUT AT 16" AFF AND VENDOR WILL CONNECT ITEM 14, SODA SYSTEM P19 1/2" COLD WATER, STUB OUT AT 1E" AFF AND CONNECT ITEM 19, PREP SINK P19b 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 19, PREP SINK P21 2" DIRECT WASTE, STUB OUT AT 12" AFF AND CONNECT ITEM 21, DISPOSER P21 b 1/2" COLD WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 21, DISPOSER p83 P84 P28 4" DIRECT WASTE, STUB OUT AT -7" AFF AND CONNECT ITEM 28, FLOOR TROUGHS. 3 LOCATIONS P29 FLOOR SINK W/HALF-GRATE, 2" INDIRECT WASTE FROM ITEM 29, DISHWASHER P30 3/4" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 30, BOOSTER HEATER. RUN OUTLET ON BOOSTER TO INLET ON DISH MACHINE, ITEM 29 P31 2" DIRECT WASTE, STUB OUT AT 12" AFF AND CONNECT ITEM 31, DISPOSER P31b 1/2" COLD WATER, STUB OUT AT 12" AFF .AND CONNECT ITEM 31, DISPOSER P32 1/2" COLD WATER, STUB OUT AT 16" AFF .AND CONNECT ITEM 32, SOILED DISHTABLE P32b 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 32, SOILED DISHTABLE - P109 P33 1/2" COLD WATER, STUB OUT AT 5.2" AFF AND CONNECT ITEM 33, HOSE REEL P33b 1/2" HOT WATER, STUB OUT AT 52" AFF AND CONNECT ITEM 33, HOSE REEL P34 1 1/2" DIRECT WASTE, `TUB OUT Al- 24" AFF AND CONNECT ITEM 34, HAND SINKS. 2 LOCATIONS P34b 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 34, HAND SINKS. 2 LOCATIONS P34c 1/2" HOT WATER, STUB OUT AT 16"' AFF AND CONNECT ITEM 34, HAND SINKS. 2 LOCATIONS P42 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 42, GAS RANGE, 215,000 BTU P44 FLOOR SINK W/HALF-GRATE, 1 1/2" INDIRECT WASTE FROM ITEM 44, COMBINATION OVEN P44b 3/4" COLD WATER, STUB OUT AT 16" AFF .AND CONNECT ITEM 44, COMBINATION OVEN. NOTE: 2 CW INLETS ON THIS OVEN MANIFOLD SUPPLY & INS FALL WATER FILTER IN 1 LINE P47 4" DIRECT WASTE, STUB OUT AT - 7" AFF AND CONNECT ITf_M 47, FLOOR TROUGH P48 EXISTING FLOOR SINK, EXTEND DRAIN LINE FOR ITEM 48, 3 COMP SINK P48b 1 /2" COLD WATER, STUB OUT AT 16" AFC' AND CONNECT ITEM 48, 3 COMP SINK P48c 1 /2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 48, 3 COMP SINK P50 1 /2" GAS CONNECTION, STUB OUT ,AT 12" AFF AND CONNECT ITEM 50, TILT SKILLET. 104,000 BTU P50b 1/2" COLD WATER, STUB OUT AT 16' AFF AND CONNECT ITEM 50, TILT SKILLET FAUCET P50C 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 50, TILT SKILLET FAUCET P55 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 55, PIZZA OVEN. 68,000 BTU P61 1 1/2" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 61 GAS RANGE & BROILER. 408,OOC BTU P63 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 63, CHARBROILER. 105,000 BTLJ P64 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 64, GRIDDLE. 81,000 BTU P65 1" GAS CONNECTION, STUB OUT AT '12" AFF AND CONNECT ITEM 65, DUAL FRYERS. 220,000 BTU P75 HUB TYPE DRAIN, 1 1/2" INDIRECT WASTE FROM ITEM 75, HANDSINK P75b 1/2" COLD WATER, STUB OUT AT 4" AFF AND CONNECT ITEM 75, HANDSINK P75c 1/2" HOT WATER, STUB OUT AT 4" AFF AND CONNECT ITEM 75, HANDSINK P80 1/2" COLD WATER, STUB OUT AT 44" AFF AND VENDOR THESE PLANS AND ALL PROPOSED WORK WILL CONNECT ITEM 80, COFFEE BREWER ARE SUBJECT TO ANY CORRECTIONS P83 EXISTING FLOOR SINK, EX IFEND DRAIN LINE F7OR REQUIRED BY FIELD INSPECTORS THAT ITEM 83, ICE BIN MAY BE NECESSARY IN ODDER TO P84 EXISTING FLOOR SINK, EXTEND DRAIN LINE F7OR COMPLY WITH ALL APPLICABLE CODES, ITEM 84, HANDSINK P84b 1/2" COLD WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 84, HANDSINK P84C 1/2" HOT WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 84, HANDSINK P87 1/2" COLD WATER, STUB OUT AT 44" AFF AND VENDOR WILL CONNECT ITEM 87, COFFEE BREWERS. 2 LOCATIONS P90 HUB TYPE DRAIN, 1 1/2" INDIRECT WASTE FROM ITEM 90, SODA DISPENSER P90b 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 90, SODA DISPENSER P93 1/2" COLD WATER, STUB OUT AT 44" AFF AND VENDOR WILL CONNECT ITEM 93, ICE TEA BREWER P97 MOP SINK- BY GC/MECHANICAL CONTRACTOR REFER TO MECHANICAL PLANS & SPECS P103 1 1/2" DIRECT WASTE, STUB OUT A-i 24" AFF FOR ITEM 104, FUTURE HAND SINK P103b 1/2" COLD WATER, STUB OUT AT 16" AFF FOR ITEM 104, FUTURE HAND SINK P103C 1/2" HOT WATER, STUB OUT AT 16" AFF FOR ITEM 104, FUTURE HAND SINK P104 HUB TYPE DRAIN, 1 1/2" INDIRECT WASTE FOR ITEM 104, FUTURE SODA DISPENSER IT P104b 1/2" COLD WATER, STUB OUT AT 16" AFF F7OR Design Group, Inc. ITEM 104, FUTURE SODA DISPENSER JacksonvlUe, Florldn 7ro u P106 1 /2" COLD WATER STUB www, axci s4 n .con OUT AT 16 AFF FOR J g g p ITEM 106, FUTURE SODA -SYSTEM Foodservice Consulting 8 Design P109 HUB TYPE DRAIN, 1/2" It'IDIRECT WASTE FRC)M ITEM 109, DRAFT BEER 1A.P Emmons THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. \W IW V I W _75 - O nI 4, nn I�I TW - aj U `W a_ O ( � 7­-1 j\' L 1. U U L� Q- PLANNING ARCHl1 ECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORiDA 32256 (904) 7 1-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos : AA26000586 LC26000508 MAIN KITCHEN PLUMBING ROUGH --IN P LAN SCALE: 1 /4"=1 V1 DRAWN BY JZ CHECKED BY GV DATE 3-26-2014 JOB NO. 13-40 SHEET NO. �- i ��� Underground Soda Line Conduit Specification., Finished Floor Line Minimum 24' Radius Minimum Diameter r- GC to provide and Install six inch diameter schedule 40 PVC with fittings for for soda line access from item 156 to bar Item 173. All joints must be solvent cemented In accordance with PVC manufacturer's recommendations to guarantee a watertight chase. Only ONE 24' or 30' radius sweep bend (45 or 90 degree) may be used at each end of chase. Conduit must be capped and seated at both ends during construction. Soda Vendor will provide & Install Items 156 and underslab soda lines to Item 173 in bar. Coordinate with Soda Vendor, 1 PLUMBING SYMBOL FLOOR SINK WITH HALF GRATE HUB DRAIN * HUB DRAIN WITH FUNNEL � DIRECT WASTE � HST OR COLD WATER 0 GAS PLUMBING ROUGH -IN SCHE-DOLE P126 1" GAS CONNECTION, STUB OUT Al 12" AFF AND CONNECT ITEM 126, DUAL FRYERS. 220,000 BTU P128 1 1/2" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 128 GAS RANGE & BROILER. 336,000 BTU P129 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 129, CHARBROILER. 60,000 BTU P131 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 131, GRIDDLE. 81,000 BTU P135 3/4" GAS CONNECTION, STUB OUT AT 12" AFF AND CONNECT ITEM 135, PIZZA OVEN. 102,000 BTU P137 1 1/2" DIRECT WASTE, STUB OUT AT 24" AF7I= AND CONNECT ITEM 137, HAND SINKS. 3 LOCATIONS P137b 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 137, HAND SINKS. 3 LOCATIONS P137c 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 137, HAND SINKS. 3 LOCATIONS P145 FLOOR SINK WITH HALF -GRATE, 1 1/2 INDIRECT WASTE FROM ITEM 145, 3 COMP SINK P145b 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 145, 3 COMP SINK P145c 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 145, 3 COMP SINK P149 3/4" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 149, BOOSTER HEATER. RUN OUTLET ON BOOSTER HEATER 1-0 INLET DN DISH MACHINE, ITEM 153 P151 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 151, SOILED DISHATBLE P151 b 1/2" HOT WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 151, SOILED DISHTABLE P152 2" DIRECT WASTE, STUB OUT AT 12" AFF AND CONNECT ITEM 152, DISPOSER P152b 1/2" COLD WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 152, DISPOSER P153 FLOOR SINK WITH HALF -GRATE, 2" INDIRECT WASTE FROM ITEM 153, DISH MACHINE P156 1/2" COLD WATER, STUB OUT AT 1()" AFF AND CONNECT I TEM 15, SODA SYSTEM P156b PVC SLEEVE IN SLAB FOR SODA LINES. RUN TO BAR ICEBIN ITEM 173. SEE DETAIL THIS SHEET P157 4" DIRECT WASTE, STUB OUT AT -7" AFF AND CONNECT ITEM 157, FLOOR TROUGH P158 HUB TYPE DRAIN, 3/4" INDIRECT WASTE FROM ITEM 158, ICE MACHINE P158b 1/2" COLD WATER, STUB OUT AT Eta" AFF AND CONNECT ITEM 158, ICE MACHINE P159 HUB TYPE DRAIN, 1 1/2" INDIRECT WASTE FRDM ITEM 159, SODA DISPENSER P159b 1/2" COLD WATER, STUB OUT AT 16" AFF AND CONNECT ITEM 159, SODA DISPENSER P160 1/2" COLD WATER, STUB OUT AT 52" AFF AND CONNECT ITEM 160, HOSE REEL P160b 1/2" HOT WATER, STUB OUT AT 52" AFF AND CONNECT ITEM 160, HOSE REEL P164 1/2" COLD WATER, STUB OUT AT 44" AFF AND CONNECT ITEM 164, ICE TEA BREWER P166 1/2" COLD WATER, STUB OUT AT 44" AFF AND CONNECT ITEM 166, COFFEE BREWERS. 2 LOCATIONS P167 MOP SINK, BY GC/MECHANICAL REFER TO MECHANICAL PLANS AND SPECS P172 FLOOR SINK WITH HALF -GRATE, 1 1/2" INDIRECT WASTE FROM ITEM 172, HANDSINK. COMMON FLOOR SINK FOR ITEMS 172 & 173 P172b 1/2" COLD WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 172, HANDSINK P172c 1/2" HOT WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 172, HANDSINK P173 FLOOR SINK WITH HALF -GRATE, 1 1/2" INDIRECT WASTE FROM ITEM 173, ICE BIN COMMON FLOOR SINK FOR ITEMS 172 & 173 P178 FLOOR SINK WITH HALF -GRATE, 1 /2" INDIRECT WASTE FROM ITEM 178, BEER COOLER COMMON FLOOR SINK FOR ITEMS 178, 179, 1 E1 & 182 P179 FLOOR SINK WITH HALF -GRATE, 1/2" INDIRECT WASTE FROM ITEM 179, STORAGE CABINET COMMON FLOOR SINK FOR ITEMS 178, 179, 161 & 182 P180 HOT WATER BOOSTER HEATER, BY GC/MECHANICAL REFER TO MECHANICAL PLANS & SPECS. RUN OUTLET ON BOOSTER HEATER TO INLET ON GLASSWASHER P181 FLOOR SINK WITH HALF -GRATE, 1 1/2" INDIRECT WASTE FROM ITEM 181, GLASSWASHER COMMON FLOOR SINK FOR ITEMS 178, 179, 151 & 182 P181b 1/2" COLD WATER, STUB OUT AT 12" AFF AND CONNECT ITEM 181, GLASSWASHER P182 FLOOR SINK WITH HALF -GRATE, 1 1/2" INDIRECT WASTE FROM ITEM 182, DUMP SINK COMMON FLOOR SINK FOR ITEMS 178, 179, 1E1 & 182 P182b 1/2" COLD WATER, STUB OUT AT 1," AFF AND CONNECT ITEM 182, DUMP SINK IT A __:5� P182c 1/2" / HOT WATER, STUB OUT AT 12` AFF AND CONNECT Design Group, Inc, Jacksonville, Florida ITEM 182, DUMP SINK 904-543-7670 P187 1/2" COLD WATER, STUB OUT AT 4-1-" AFF AND VENDOR www, jaxdesigngroup,com Foodservlce Consulting & Design WILL CONNECT ITEM 187, COFFEE BREWER MINION ■ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. 0i Ul V Oil ICU I� -- 0 nn�1 W U - (j 0-) U (+- C - 0 r n ' n n <1 L-D BASHAM & LUCAS DESIGN GROUP, INC. PLANNING !ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, ##201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lie. Nos. AA26000586 LC26000508 KITCHEN & BAR PLUMBING ROUGH -IN P LAN SCALE: 1 /4"=1 '0" DRAWN BY JZ CHECKED BY GV DATE 3-26-2014 JOB NO. 1 ;-40 SHEET NO. F S l ; 0 CE6 Off ice Verify 'OCO, tionis v E45 on Arch/MeCh plans E35 E45b W H E45c t E3 E30 ) E7 E5 / vm r, IT Design Group, Inc. Jacksonville, Florida 904-543-7670 www.jaxdeslgngroup.com Foodservice Consulting & Design -7 0 7 �Lr ELECTRICAL SYMBOL KEY C)= DUPLEX RECEPTACLE, 120V. GROUND TYPE G-- SIMPLEX RECEPTACLE, 120V, GROUND TYPE JUNCTI❑N BOX ELECTRICAL STUB -OUT WALL SWITCH Q SPECIAL PURPOSE OUTLET, 120V, GROUND TYPE Q SPECIAL PURPOSE OUTLET, 208/240V, AS INDICATED (D P❑S/PRINTER SYSTEM DATA CABLE —ill► �i1Fir, �II► PRE +III j ej ro u E55 E56 10'=6" I 3,15r o E76 E87 E87 o Nt .A6, 0 E 1 0:5D -4 r� I I I I I 1 I E104 E106 101-9' E82b / E82 I a E82b 1155I�' twill1 E112 E108 E82a � E82 i E116 X,"")y r v THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED UY FIELD INSPECTORS THAT MAY BE NECESSARY IN (TRUER TO COMPLY WITH ALL APPLICABLE CODES. ELECTRICAL ROUGH -IN 'S)CHEGULE E1 120—V 1 PH SERVICE, 5.0 AMPS. ELECTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 1, COOLERAREEZER LIGHTS E1b 120—V 1 PH SERVICE, 5.0 AMPS. ELECTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 1, FREEZER DOOR HEATER. WIRE SEPERATELY FROM LIGHTS AND CONNECT ASTART—UP ONLY E2 120—V 1 PH SERVICE, 1.8 AMPS. ELECTRICAL_ CONNECTION AT 108" AFF FOR SERVICE AT ITEM 2, COOLER EVAPORATOR COIL. E3 208—V 3 PH SERVICE, 9.4 AMPS. ELECTRICAL. CONNECTION AT 36" AFF FOR SERVICE AT ITEM 3, COOLER REMOTE C/U. VERIFY LOCATION ON ARCH/MECH PLANS E4 120—V 1 PH SERVICE, 1.8 AMPS. I LECTRICAL_ CONNECTION AT 108" AFF FOR SERVICE AT ITEM 4, BEER COOLER EVAPORATOR COIL E5 208—V 3 PH SERVICE, 5.8 AMPS. ELECTRICAL. CONNECTION AT 36" AFF FOR SERVICE AT ITEM 5, BEER COOLER REMCTE C./U. VERIFY LOCATION ON ARCH/MECH PLANS E6 208—V 1 PH SERVICE, 8.8 AMPS. ELECTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 6, FREEZER EVAPORATOR COIL E7 208—V 3 PH SERVICE, 8.9 AMPS. ELECTRICAL. CONNECTION AT 36" AFF FOR SERVICE AT ITEM 7, FREEZER REMOTE C/U. VERIFY LOCATION ON ARCH/MECH PLANS E10 208—V 3 PH SERVICE, 5.6 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 10, FLOOR MIXER. GC/EC TO PROVIDE & INSTALL CORD & PLUG E14 120—V 1 PH SERVICE, 7.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 14, SODA SYSTEM E16 120—V 1 PH SERVICE, 12.5 AMPS. ELECTRICAL_. OUTLET AT 48" AFF FOR SERVICE AT ITEM 16, BENCH MIXER E18 120—V 1 PH SERVICE, 12.5 AMPS. ELECTRICAL_. OUTLET AT 48" AFF FOR SERVICE AT ITEM 18, FOOD PROCESSOR E21 208—V 3 PH SERVICE, 6.2 AMPS. ELECTRICAL. CONNECTION AT 12" AFF FOR SERVICE AT ITEM 21, DISPOSER E29 208—V 3 PH SERVICE, 46.0 AMPS. ELECTRICAL CONNECTION AT 66" AFF FOR SERVICE AT ITEM 29, DISHWA';HER E30 208—V 3 PH SERVICE, 41.7 AMPS ELECTRICAL- CONNECTION AT 16" AFF FOR SERVICE AT ITEM 30, BOOSTED HEATER E31 208—V 3 PH SERVICE, 6.6 AMPS. ELECTRICAL CONNECTION AT 12" AFF FOR SERVICE AT ITEM 31, DISPOSER E35 120—V 1 PH SERVICE, 2.0 KW. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 35, MOBILE HEATED CABINET. VERIFY PLUG TYPE E36 120—V 1 PH SERVICE, 20.0 AMPS, ELECTRICA_ OUTLET AT 6" AFF FOR SERVICE AT ITEM 36, MOBILE PREP TABLE. 2 LOCATIONS, WATERPROOF TYPE I-LOOR MOUNTED OUTLETS E43 208—V 3 PH SERVICE, 33.0 AMPS. ELECTRICAL_ OUTLET AT 36" AFF FOR SERVICE AT ITEM 43, ROTISSI RIE. GC/EC TO PROVIDE & INSTALL CORD & PLUG E44 208—V 3 PH SERVICE, 98.5 AMPS. ELECTRICAL_ CONNECTION AT 36" AFF FOR SERVICE AT ITEM 44, COMBINATION OVEN, DEDICATED CIRCUIT REQ'D. DO NOl CONNECT TO GFI OUTLET E45 120—V 1 PH SERVICE, 2.5 AMPS. ELECTRICAL_ CONNECTION AT 108" AFF FOR SERVICE AT ITEM 45, EXHAUST HOOD LIGHTS E45b 208—V 3 PH SERVICE, 6.2 AMPS. ELECTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 45, EXHAUST FAN. INTERCONNECT CONTROL PANEL ON HOOD W,/F-AN ON ROOF E45c 208—V 3 PH SERVICE, 3.3 AMPS. ELECTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 45, MAKE—UP AIR FAN, INTERCONNECT CONTROL PANEL ON HOOD W✓:-AN ON ROOF E50 120—V 1 PH SERVICE, 1.0 AMPS. I LECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 50, GAS TIL I- SKILLET E55 120—V 1 PH SERVICE, 2.0 AMPS. ELECTRICAL_ WALL SWITCH AT 44" AFF FOR SERVICE AT ITEM 55, GAS PIZZA OVEN. PROVIDE DOUBLE POLE WALL SWITCH, RUN TC OVEN AND EXHAUST FAN, ITEM 56 E56 120—V 1 PH SERVICE, 1.4 AMPS. ELECTRICAL. WALL SWITCH AT 44" AFF FOR SERVICE AT ITEM 56, PIZZA OVEN EXHAUST FAN. PROVIDE DOUBLE POLE WALL SWITCH, RUN TO OVEN AND EXHAUST FAN ON ROOF E61 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 61, RANGE E62 120—V 1 PH SERVICE, 7.4 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 62, REF CHEFS BASE E65 120—V 1 PH SERVICE, 7.0 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 65, GAS FRYERS E70 120/208—V 1 /3 PH SERVICE, 125.0 AMPS. ELECTRICAL CONNECTION AT 4" AFF FOR SERVICE AT ITEM 70, S/S CHITS COUNTER. PRE —WIRED SINGLE POINT CONNEC HON W/PANEL BOX, POWER SUPPLY FOR ITEMS: 66, 68, 69, 71, 72a, 73, 74, 118 & 119 E72a DATA LINE REQUIRED FOR VENDOR SUPPLIED/INSTALLED EQUIPMENT FOR SERVICE AT ITEM 72a, POS SYSTEM PRINTER E72b1 120—V 1 PH SERVICE, 2.5 AMPS. ELECTRICAL. OUTLETS AT 48" AFF FOR SERVICE AT ITEM 72b, POS SYSTEM PRINTERS. 3 LOCATIONS E72b2' DATA LINE REQUIRED FOR VENDOR SUPPLIED,/INSTALLED EQUIPMENT FOR SERVICE AT ITEM 72b, POS SYSTEM PRINTERS 3 LOCATIONS E76 120—V 1 PH SERVICE, 9.0 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 76, PIZZA PREP TABLE E77 120 —V 1 PH SERVICE, 6.9 AMPS. ELECTRICAL. OUTLET AT 84" AFF FOR SERVICE AT ITEM 77, REACH —IN REF E78 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL. OUTLET AT 48" AFF FOR SERVICE AT ITEM 78, S/S BEVERAGE TABLE E80 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL. OUTLET AT 48" AFF FOR SERVICE AT ITEM 80, COFFEE BREWER E82 120—V 1 PH SERVICE, 5.0 AMPS. ELECTRICAL. OUTLET AT 48" AFF FOR SERVICE AT ITEM 82, POS SYSTEM CASH REGISTERS. VENDOR SUPPLIED EQPT, VERIFY LOCATIONS AND QUANTITIES W/OWNER E82b DATA LINE REQUIRED FOR VENDOR SUPPLIED,/INSTALLED EQUIPMENT FOR SERVICE AT ITEM 82, POS SYSTEM/CASH REGISTERS. VENDOR SUPPLIED EQPT, VERIFY LOCATIONS AND QUANTITIES W/OWNER E87 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL, OUTLET AT 48" AFF FOR SERVICE AT ITEM 87, COFFEE BREWERS. 2 LOCATIONS E89 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL, OUTLET AT 48" AFF FOR SERVICE AT ITEM 89, BEVERAGE TABLE E90 120—V 1 PH SERVICE, 12.5 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 90, SODA DISPENSER E92 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL. OUTLET AT 48" AFF FOR SERVICE AT ITEM 92, BEVERAGE TABLE E93 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48' AFF FOR SERVICE AT ITEM 93, ICE TEA BREWER E94 120—V 1 PH SERVICE, 6.9 AMPS. ELECTRICAL. OUTLET AT 84" AFF FOR SERVICE AT ITEM 94, REACH —IN REF E104 120—V 1 PH SERVICE, 12.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 104, FUTURE SODA DISPENSER E105 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 105, FUTURE WORKTABLE E106 120—V 1 PH SERVICE, 7.5 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 106, FUTURF SODA SYSTEM E108 120—V 1 PH SERVICE, 5.5 AMPS. 1-1_ECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 108, BACKBAR REF. REPLACEMENT OF EXIST EQPT, VERIFY EXIST POWER, SHOULD BE SUFFICIENT E112 120—V 1 PH SERVICE, 5.2 AMPS. 11_`CTRICAL. OUTLET AT 12" AFF FOR SERVICE AT ITEM 112, BOTTLE COOLER REPLACEMENT OF EXIST EQPT, VERIFY EXIST POWER, SHOULD BE SUFFICIENT E116 120—V 1 PH SERVICE, 5.2 AMPS. I I-ECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 116, BOTTLE COOLER REPLACEMENT OF EXIST EQPT, VERIFY EXIST POWER, SHOULD BE SUFFICIENT r m ( o_ c!� w Q .> C� fL w Q 0 0 z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. W L � I I(I Vn L 0 tk U U `-t-- W (1 I - O � S rn CL CL PLANNING •ARCHITECTURE LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 LC26000508 N/1A1 N KITCHEN E LECTR I CAL ROUGH -IN 1 PLAN 1 SCALE: 1 /4"=1'0" DRAWN BY + JZ —— CHECKED BY GV DATE 3-26-201 4 JOB NO. 13-40 SHEET NO. F S '12 ELECTRICAL SYMBOL KEY DUPLEX RECEPTACLE, 120V, GROUND TYPE G— SIMPLEX RECEPTACLE, 120V, GREIUND TYPE ® JUNCTION BOX C) ELECTRICAL STUB -OUT WALL SWITCH O SPECIAL PURPOSE OUTLET, 120"', GROUND "TYPE Q SPECIAL PURPOSE OUTLET, 208/240V, AS INDICATED ® P❑S/PRINTER SYSTEM DATA CABLE ELECTRICAL ROUGH -IN S1�,HEDULE E122 120—V 1 PH SERVICE, 8.6 AMPS. ELECTRICAL OUTLET AT 90" AFF FOR SERVICE AT ITEM 122, ROLL —IN REF E123 120—V 1 PH SERVICE, 9.3 AMPS. ELECTRICAL_ OUTLET AT 90" AFF FOR SERVICE AT ITEM 123, REACH —IN FREEZER E125 120—V 1 PH SERVICE, 2.5 AMPS. ELLCTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 125, EXHAUST HOOD LIGHTS E125b 208—V 3 PH SERVICE, 9.5 AMPS. ELLCTRICAL CONNECTION AT 108" AFF FOR SERVICE AT ITEM 125, EXHAUST FAN. INTERCONNECT CONTROL PANEL ON HOOD W/ELAN ON ROOF E125c 208—V 3 PH SERVICE, 4.7 AMPS. ELECTRICAL CONNE-CTION AT 108" AFF FOR SERVICE AT ITEM 125, MAKE—UP AIR FAN. INTERCONNECT CONTROL PANEL ON HOOD W/:7AN ON ROOF E126 120—V 1 PH SERVICE, 7.0 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 126, DUAL FRYER E130 120—V 1 PH SERVICE, 6.0 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 130, REF CHEFS BASE E133 120—V 1 PH SERVICE, 9.0 AMPS. ELECTRICAL. OUTLET AT 16" AFF FOR SERVICE AT ITEM 133, REF PIZZA PREP 'TABLE - El 35 120—V 1 PH SERVICE, 1.1 AMPS. ELECTRICAL WALL SWITCH AT 44" AFF FOR SERVICE AT ITEM 135, GAS PIZZA OVEN. PROVIDE DOUBLE POLE WALL SWITCH, RUN TO OVEN AND EXHAUST FAN, ITEM 136 E136 120—V 1 PH SERVICE, 2.9 AMPS. ELECTRICAL_ WALL SWITCH AT 44" AFF FOR SERVICE AT ITEM 136, PIZZA OVEN EXHAUST FAN. PROVIDE DOUBLE POLE WALL SWITCH, RUN TO OVEN AND EXHAUST FAN ON ROOF E138 120—V 1 PH SERVICE, 5.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 138, REF SANDWICH UNIT E140 120—V 1 PH SERVICE, 6.7 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 140, SOUP WELLS. 3 LOCATIONS E142 120—V 1 PH SERVICE, 9.0 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 142, WORKTOP REF E146 120—V 1 PH SERVICE, 15.0 AMPS. EL[7CTRICAL. OUTLET LOCATION TBD FOR SERVICE AT ITEM 146, MILLWORK SERVICE: COUNTER. CONVENIENCE OUTLETS, COORDINATE W/MILLWORK DWGS 2 LOCATIONS E147 120—V 1 PH SERVICE, 10.0 AMPS. ELECTRICAL OUTLET LOCATION TBD FOR SERVICE AT ITEM 147, MILLWORK SERVICE COUNTER. CONVENIENCE OUTLET, COORDINATE W/MILLWORK DINGS E149 208—V 3 PH SERVICE, 41.7 AMPS. ELECTRICAL CONNECTION AT 16" AFF FOR SERVICE AT ITEM 149, BOOSTER HEATER E152 208—V 3 PH SERVICE, 6.6 AMPS. ELI CTRICAL_ CONNECTION AT 12" AFF FOR SERVICE AT ITEM 152, DISPOSER E153 208—V 3 PH SERVICE, 46.0 AMPS. El ECTRICA'._ CONNECTION AT 66" AFF FOR SERVICE AT ITEM 153, DISHWASHER E156 120—V 1 PH SERVICE, 7.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 156, SODA SYSTEM E158 120—V 1 PH SERVICE, 11.7 AMPS. ELECTRICAL CONNECTION AT 66" AFF FOR SERVICE AT ITEM 158, ICE MACHINE E159 120—V 1 PH SERVICE, 12.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 159, SODA DISE'ENSER E162 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 162, BEVERAGE TABLE E164 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL_ OUTLET AT 48" AFF FOR SERVICE AT ITEM 164, ICE TEA E3REWER E165 120—V 1 PH SERVICE, 5.5 AMPS. ELECTRICAL OUTLET AT 16" AFF FOR SERVICE AT ITEM 165, WORKTOP REFRIGERATOR E166 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 166, COFFEE BREWERS,. 2 LOCATIONS E175 120—V 1 PH SERVICE, 3.2 AMPS. ELECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 175, WINE CHILLER E176 120—V 1 PH SERVICE, 5.5 AMPS. ELECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 176, BACKBAR COOLER E177 120—V 1 PH SERVICE, 5.8 AMPS. ELECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 177, GLASS CHILLER E178 120—V 1 PH SERVICE, 5.5 AMPS. ELECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 178, DRAFT BEER COOLER E180 HOT WATER BOOSTER HEATER FOR GLASSWASHER, ITEM 181 BY MECHANICAL— REFER TO MECHANICAL PLANS & SPECS E181 120—V 1 PH SERVICE, 11.0 AMPS. ELECTRICAL_. CONNECTION AT 12" AFF FOR SERVICE AT ITEM 181, GLASSWASH ER E185 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 185, POPCORN MAKER E186 120—V 1 PH SERVICE, 2.0 AMPS. ELECTRICAL OUTLET AT 12" AFF FOR SERVICE AT ITEM 186, UNDERCOUNTER REF E187 120—V 1 PH SERVICE, 15.0 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 187, COFFEE BREWER E188 120—V 1 PH SERVICE, 6.4 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 188, HOT DOG ROLLER E189 120—V 1 PH SERVICE, 4.2 AMPS. ELECTRICAL OUTLET AT 48" AFF FOR SERVICE AT ITEM 189, BUN WARMER li- _Z_l�x Design Group, Inc. Jacksonville, Florida 904-543-7670 www. jaxdesigngroup,com Foodservice Consulting & Design � milli I ■ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. _- 0 U U Q� L -I n O � �J CL Q LD Cl— i YJ 90 E0112• ' PLANNING •ARCHITECTURE 4 ANDSCAPE 7645 GATE. PARKWAY, #20I JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com 1-1c. Nos: AA26000586 LC26000508 KITCHEN & BAR ELECTRICAL ROUGH --IN P LAN SCALE: 1 /4"=1 '0" DRAWN BY JZ CHECKED BY Gv DATE 3-26-2014 JOB NO. SHEET NO. C F L