HomeMy WebLinkAboutConcrete Inspection Report� *ham 4� . -�, •�� !�� ' w.r
GFA PROJECT#
12-1287.01
�KNA1►"
PROJECT
PGA VILLAGE CLUBHOUSE ADDITION
LOCATION
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
Phone:
CONCRETE PLACEMENT
INSPECTION REPORT
DATE Tuesday, November 25, 2014
S M T W TH F S
DAY 25TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0006A
LOW
MODERATE
HIGH
IG
MEMBERS/AREA INSPECTED: MASONRY WALLS, FILL CELLS (1ST 10 YARDS PLACED IN SI
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS
AND ACCEPTED PRACTICES.
COMPLIES
YES
NO N/A
X
1 SPARE VIBRATOR ON HAND
X
2 FORMS WETTED/OILED
X
(1)
3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
X
4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
X
5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAY'S POUR
(2)
6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
X
7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
X
8 SUFFICIENT VIBRATION PERFORMED
X
9 STEEL REMAINED IN PLACE DURING POUR
X
X
10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
AREA POURED
YDS
PSI
TYPE MIX
SLUMP
IN # IN
START TIME
END TIME
METHOD OF
PLACEMENT
SUPPLIER
MASONRY SILLS
10
3,000
#8PM
5-7
7:50
8:45
PUMP
TITAN
FILL CELLS
10
3,000
M6-C
10:00
10:30
PUMP
TITAN
FILL CELLS
10
3,000
M6-C
11:15
12:00
PUMP
TITAN
TIE BEAM
10
3,000
#8PM
5-7
14:00
15:30
1 PUMP
TITAN
TIE BEAM
10
3,000
#8PM
5-7
16:00
17:30
1 PUMP
TITAN
FILL CELLS
11
1 3,000
1 M6-C
18:00
19:30
1 PUMP
TITAN
Disposition of Inspection
[Z]Section / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED
AT 8:20 AM.
Re -Inspection
Re -Inspection Required
10 GALLONS ADDED PRIOR TO PLACEMENT (8:00
r Inspection Performe yy dbHN
7y: Inspection Certifi By:;
.PAS LILH.'
Registered Professionv N "T.E. #44E
ap
• r�l
APR 2 7 RECD Certified Special Inspector1j(0 11 3
•.
FBPE Certificate Nis ••.
Environ ental . Geotechnical . Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code Co
Florida's Leading Engineering Source
ADDED
ITE, VN
GFA PROJECT # 12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION
LUCIE, FL
PERMIT NO.
1404-0063
OWNER
WEATHER
CONTRACTOR
KAST
TEMPERATURE
ARCHITECT
WIND
ENGINEER
HUMIDITY
TYPE OF INSPECTION: REVIEW OF FOUNDATIONS CAST
MEMBERS/AREA INSPECTED: ITEMS NOT INSPECTED BY GFA
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Thursday, October 30, 2014
S M T W TH F S
DAY x
BRIGHTSUN
CLEAR
OVERCAST
RAIN
BELOW 60
60-75
75-90
ABOVE 90
LOW
MODERATE
HIGH
Report No
1
LOW
MODERATE
HIGH
REMARKS:
1. RECEIVED COPIES OF MIX DESIGNS, KAST SUBMITTAL #1, 9/12/2014
* a) NOT STAMPED BY FOR
2. REVIEWED PHOTO'S OF FOOTINGS PRIOR TO CONCRETING
a) PHOTOS BY CONTRACTOR, TIME/DATE STAMP 10/10/2014.
b) RECEIVED COPIES OF CONCRETE DELIVERY TICKETS, FOR 20 YARDS OF 3500 PSI, MIX #SW7B5R30 (FOOTING MIX) 10/10/14
3. PREVIOUS CONCRETE POURS
10/3/14 FOOTINGS 20 YDS. #SW7B5R30
10/10/14 FOOTINGS 20 YDS. #SW7B5R30
10/17/14 FOOTINGS 10 YDS. #SW7B5R30
10/24/14 CELL FILL 10 YDS JAG (ILLEGIBLE) CMG
Disposition of Inspection
Section / Area Approved Re -Inspection
Work In Progress RX Re -Inspection Required
COMMENTS/ACTION REQUIRED: 1) PHOTOS INDICATE CORRECT REINFORCEMENT; ANCHOR BOLTS (J-BOLTS) EXTEND TO
BOTTOM REINFORCED MAT
2 CONCRETE TICKETS INDICATE THE CORRECT MIX # "a
Inspection Performed By: ,
Inspection Certified B`♦ : �� %: 4015
I H. ; •
Registered Professional 11: P . #_ 53
IE0IE 0ML :1 .Im is
Certified Special Inspector �o: 1 03
FBPE Certificate N1a: �10 pT� C .�
Envi e t • Geotechnical . Construction Materials Testing . Special & Threshold Inspections .Plan Review 8 YMoce Q `•� ��
,,�i
Florlda's Leading Engineering Source
GFA PROJECT #
PROJECT
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
12-1287.01
PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LUCIE, FL
1404-0008
KAST
WEATHER
TEMPERATURE
WIND
HUMIDITY
S
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Wednesday, January 14, 2015
S M T W TH F S
DAY 14TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0014
LOW
MODERATE
HIGH
X
TYPE OF INSPECTION: WINDOW ANCHORING.
MEMBERS/AREA INSPECTED: SEVEN (7) MARK',C' WINDOW FRAMES AND ONE (1) MARK'157A' TRU LITE
RESISTOR 350 STOREFRONT DOOR NOA# 12-0117.05. THREE (3) WINDOWS AT RESTAURANT (ROOM NO. 111),
FOUR (4) WINDOWS AT BANQUET ROOM (#154) - DOOR AT BANQUET ROOMS.
REMARKS; SEE ATTACHED PLAN FOR LOCATIONS.
Disposition of Inspection
NSection / Area Approved Re -Inspection
Work In Progress RRe-Inspection Required
COMMENTS/ACTION REQUIRED:
Inspection Performed By: JO kRl 1w t1j!43
Inspection Certified By: Its,5
onal W.IAq . •
Registered Professional N • P/F;•6067 4653 •.
a�
—T Certified Special Inspector Ni N// * e
FBPE Certificate N4�3�GTA-rE
Environme tVtruechnical .Consction Materials Testing -Special & Threshold Inspections -Plan Review & c%101iaro� O R ` p P•i \�,��
APR 2 7 RECtD Florida's Leading Engineering Source ,0 2 . SS, ..... • �,��
.,���iO N A'
t
v 7 EAI -' .1�f � •
GFA PROJECT #
PROJECT
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
12-1287.01
PGA VILLAGE CLUBHOUSE ADDITION
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
1404-0063
PGA OF AMERICA WEATHER
KAST CONSTRUCTION' TEMPERATURE
N/A WINO
N/A HUMIDITY
Phone: (772) 924-3575 Fax: (772) 924-3580
REINFORCING STEEL
INSPECTION REPORT
DATE Tuesday, February 10, 2015
S M T W I TH F S
DAY 10TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
0018
X
X
MEMBERS/AREA INSPECTED: 1) SIGN FOOTINGS AT ENTRANCE (REFERENCE DRAWINGS H1.2).
2) NEW TIE BEAM OVER DOORWAY BETWEEN ROOM NOS. 157-158.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
X
1 SOIL BEARING CAPACITY
X
2 BUILDING LOCATION
X
3 BUILDING SLAB ELEVATION
X
4 TERMITE TREATMENTVERIFIED
X
5 COMPACTION TESTING
X
6 FORMING DIMENSIONS
X
7 INSIDE OF FORMS CLEAN
X
8 WIRE MESH REINFORCING SIZE AND LAP
X
9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING
X
10 SPLICES
X
11 REBAR CLEAN AND FREE OF OIL
X
12 REBAR CLEARANCE FROM FORMS AND EARTH
X
13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED
X
14 SHORING AND RE -SHORING
X
15 POST TENSIONED CABLE LAYOUT AND PROFILE
Disposition of Inspection
X Section / Area Approved Re -Inspection
RRe-Inspection
Work In Progress
Required
COMMENTS/ACTION REQUIRED:
APR 2 7 OECD D
Inspection Performed
Inspection Certified Bya
Registered Professional No
Certified Special Inspector No:
FBPE Certificate No:
�-ITV
i
rr__ : \ �i
r�PO LE a, BIB,# 954k
4122
4 H. D ORTH, PbF
�#4465 T T Eft
• Construction Materials Testing • Special & Threshold Inspections . Plan Review & Code Compliance
Florida's Leading Engineering Source
FILE COPY
521 Enterprise Drive, Port St Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
i
PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION
LUCIE, FL
PERMIT NO.
1404-0063
OWNER
WEATHER
CONTRACTOR
KAST
TEMPERATURE
ARCHITECT
WIND
ENGINEER
HUMIDITY
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Wednesday, February 11, 2015
S M T W TH F S
DAY 11TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0019
LOW
MODERATE
j HIGH
X
TYPE OF INSPECTION: PARTIAL TRUSS ENGINEERING (ONLY).
MEMBERS/AREA INSPECTED:
TRUSS ENGINEERING IN ROOM # 157 (PAVILION), ROOM # 156 (ANTI ROOM), ROOM # 158 (PATRON TERRACE).
OBSERVATIONS:
1) ROOM # 158
A) RAT RUN AT EAST END OF TRUSS NOS. B01 IS NOT CONTINUOUS.
B) WEB BRACES AT WEST END ARE MISSING.
C) TRUSS # MT 01, (2) PLY TRUSS, BOTTOM CHORD NAILING IS NOT PER DETAIL AT CENTER.
2) ROOM # 157
Disposition of Inspection
RX
Section / Area Approved Re -Inspection
Work In Progress RX Re -Inspection Required
COMMENTS/ACTION REQUIRED:
Inspection Performed By: �•IVfa ���
Inspection Certified BY,$ 653 4!i tfls
P H. Da ort, .
R nEO0
Registered Professional IN 44653 I
v Certified Special Inspector N y •103
• STA ;
FBPE Certificate NOK *. a ? .•
• Geotechnical • Construction Materials Testing • Special & Threshold Inspections e Plan Review & Cod • •;•:;n^`
•
&•-
Florida's Leading Engineering Source ���� /O N y
'01I/11111111
521 NW
GFA PROJECT#
Port St Lucie. Florida
12-1287.01
PROJECT PGA VILLAGE CLUBHOUSE ADDITION
LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO. 1404-0008
OWNER PGA OF AMERI
CONTRACTOR KAST CONSTRUCTION
ARCHITECT N/A
Phone: (772)924-3575 Fax: (772) 924-3580
TRUSS ENGINEERING AND SHEATHING
INSPECTION REPORT
WEATHER
TEMPERATURE
WIND
DATE Thursday, February 12, 2015
S M T W TH F S
DAY 12TH
ENGINEER N/A HUMIDITY
MEMBERS/AREA INSPECTED: TRUSS ENGINEERING AT ROOM NOS. 126A, 126B, 127A, 127B, 128, 129, (130-
140), (142-151), 152, 155.
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
X
Report No
MODERATE
HIGH
PO-W7
0021
X
COMMENTS: 1) FG05 IA ST SKYLIGHTS, (4) TRUSSES, T-BRACES MISSING.
2) (2) FG04 IS AT NORTH END ROOM # 142 AND SOUTH END ROOM # 140.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
X 1 APPROVED TRUSS ENGINEERING SHOP DRAWINGS ON SITE
(1) 2 TRUSS ENGINEERING (SCAB BRACES, T-BRACES, L-BRACES, CLB)
X 3 BOTTOM CHORD BRACING
X 4 GABLED END BRACING
X 5 UPLIFT (STRAPS(no slack for movement), BUCKETS, NAILS, BOLTS)
X 6 REACTIONS (BUCKETS; COLUMNS, BEARING, NAILS, BOLTS)
X 7 WEBS, TOP CHORDS, BOTTOM CHORDS AND JOINTS ARE NOT BROKEN, CUT OR DAMAGED
X 8 PLACEMENT OF TRUSSES
X 9 BEARING WALL FRAMING (SIZE, SPACING, STRAPS, NAILS, BOLTS)
X 10 WOOD SEPARATED FROM CONCRETE OR MASONRY
X 11 PLACEMENT AND THICKNESS OF SHEATHING
X 12 NAILING OF SHEATHING
X 13 REMOVAL OF SHINERS
X 14 CONDITION OF SHEATHING
X 15 BLOCKING OF SHEATHING AT GABLED ENDS
X 16 PLACEMENT OF FIRE RATED SHEATHING
M
ion of Inspection
Section / Area Approved Rx
Re-Inspection
Work In Progress Re -Inspection Required
COMMENTS / ACTION REQUIRED:
-- - -- —� �. •..- E N-...•,�,
rN II
V� U Inspection Performed By. CO T ET BN#.25
D �.
Inspection Certified Byr ,k w 414
Pau;H. Danforth, P*.
APR 2 7 RECD Registered Professional Nos• P.E• 44653 :
Certified Special Inspector No 1�-1. STAGE OF ;
_�.
form revised 9/21/06 FBPE Certificate No: � 0�':c� 0 R
Environmental : Geotechnical • Construction Materials Testing . Special & Threshold Inspections e Plan Review & Code A6 ce ��
Florida's Leading Engineering Source 4,/11111:10
FILE
COP"-
521 Enterprise Drive. Port St Lucie. Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION
LUCIE, FL
PERMIT NO.
1404-0063
OWNER
WEATHER
CONTRACTOR
KAST
TEMPERATURE
ARCHITECT
WIND
ENGINEER
HUMIDITY
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Friday, February 13, 2015
S I M T I W TH F S
DAY 13TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
BELOW 60
60-75
75-90
ABOVE 90
LOW
MODERATE
HIGH
Report No
0022
LOW
MODERATE
HIGH
TYPE OF INSPECTION: TRUSS (PARTIAL)
MEMBERS/AREA INSPECTED:
INSPECT CLIP INSTALLTION FOR TRUSS TO MASONRY CONNECTIONS, ROOM # 124 (MEMBER DINING).
COMMENTS:
1) TRUSS NO. EA, EJ3, EJ4
A) CLIPS ARE NOT PER FASTENED SCHEDULE.
2) TRUSS GIRDER A09G
A) CLIPS ARE NOT PER FASTENED SCHEDULE, STRAP 1-SIDE ONLY.
3) TRUSS #A10
A) CLIPS ARE NOT PER SCHEDULE - STRAP 1-SIDE ONLY.
4) TRUSS #A01
A) 6 - TRUSSES, CLIPS NOT PER SCHEDULE. STRAPS ARE 1-SIDE ONLY WITH TWIST STRAPS OPPOSITE SIDE TAPCON
ANCHORS INTO CONCRETE.
5) TRUSS A04
A) T-BRACE NEEDS TO BE RENAILED.
6) TRUSS GIRDER # A08G
A) 13 #10 NAILS USED WHERE 18 #10 ARE REQUIRED (DETA20)
7) TRUSS #HJ5A
A) CLIP IS NOT PER SCHEDULE, EMBEDDED STRAP 1-SIDE, TWIST STRAP OTHER SIDE.
Disposition of Inspection
Section / Area Approved Re -Inspection
Work In Progress RX Re -Inspection Required
COMMENTS/ACTION REQUIRED:
D
n APR 2 7 OECD
II
w Environmental • Gf
Inspection Performed By:
Inspection Certified BF.
Registered Professional l�b�
Certified Special Inspector Igo:
FBPE Certificate Nb:
• construction Materials Testing • Special & Threshold Inspections • Plan Review
Florida's Leading Engineering Source
E. 44653
110
Imo STATE OF
wh 0 Ft :
9/ONA,
r � • o
�o
A It
k.
WSnNo.�NS��
1
PROJECT PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION LUCIE, FL
PERMIT NO.
1404-0068
OWNER
WEATHER
CONTRACTOR
KAST TEMPERATURE
ARCHITECT
WINE)
ENGINEER
HUMIDITY
TYPE OF INSPECTION: ROOF TRUSS CONNECTIONS
MEMBERS/AREA INSPECTED:
Phone: (772) 489-9989 Fax. (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Thursday, February 19, 2015
S M I T I W 1TH F I S
DAY 19TH
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0023
LOW
MODERATE
HIGH
X
TRUSS TO MASONRY CONNECTIONS AT ROOM NO. 125 (MEMBER BAR)
1/ TRUSS #F09G, #F04G
A) DETAIL NEEDED (UPLIFT >2300#)
2/ TRUSS #H2JK,
A) NO EMBEDDED STRAPS
B) (1) TWIST STRAP USED (ANCHORING TO CONCRETE IS (4) TAPCONS AT 1" O.C.)
3/ TRUSS # Hi F, (WEST)
A) (1) 16" STRAP (2 REQUIRED)
4/ TRUSS # CJ3F (EAST OF #HJ1 F)
A) (1) 16" IN LIEU OF (2) 12" STRAPS
5/ TRUSS #EJ1 OF
A) LESS THAN (10) NAILS
6/ TRUSS # HJ2F
A) (1) 16" STRAP (2 REQUIRED)
TRUSS TO TRUSS GIRDER CONNECTIONS AT ROOM # 125 (NO EXCEPTION TAKEN).
Disposition of Inspection
Section / Area Approved Re -Inspection
Work In Progress RX Re -Inspection Required
COMMENTS/ACTION REQUIRED:
Inspection Performed By-,
Inspection Certified Bg
E(� 2 O �l/ f� Registered Professional 4:
. L� V L5 Certified Special Inspector N
FBPE Certificate Nor
Geotechnical • Construction Materials Testing • Special & Threshold Inspections . Plan Review &
Florida's Leading Engineering Source
%%"tJ11111111
ANF
• _
N0 53 4!�'-VS
II H. Danforth, P.E.
E. 44653
1103in EW
O N P►L
�//1111111�
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE ADDITION
LOCATION
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION.
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
MEMBERS/AREA INSPECTED: SIGN WALL (14/H1
Phone: (772) 924-3575 Fax: (772) 924-3580
REINFORCING STEEL
INSPECTION REPORT
DATE Tuesday, March 03, 2015
S I M I T I W I TH I F I S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
j
0023B
X
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO
N/A
X
1 SOIL BEARING CAPACITY
X
2 BUILDING LOCATION
X
3 BUILDING SLAB ELEVATION
X
4 TERMITE TREATMENT VERIFIED
X
5 COMPACTION TESTING
X
6 FORMING DIMENSIONS
X
7 INSIDE OF FORMS CLEAN
X
8 WIRE MESH REINFORCING SIZE AND LAP
X
9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING
X
10 SPLICES
X
11 REBAR CLEAN AND FREE OF OIL
X
12 REBAR CLEARANCE FROM FORMS AND EARTH
X
13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED
X
14 SHORING AND RE -SHORING
X
15 POST TENSIONED CABLE LAYOUT AND PROFILE
Disposition of Inspection
X Section / Area Approved Re -Inspection
Work In Progress RRe-Inspection Required
COMMENTS/ACTION REQUIRED: VERIFIED DEPTH AND PREP FOR EPDXY DOWELS TRUSS # FG01 AT ROOM #124.
.�NI{Illlf//
APR 2 1 OECD
Inspection Performed
�:
Inspection Certified B)C * .
PA JL
Registered Professional NC P(Fr e
Certified Special Inspector No -Z&
i A
FBPE Certificate No: 4AD
4;�7201S
H. DANF H, P.E.
14653
a STATh '-Jr :'.01
Environmental . Geotechnical . Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code Complianeelf/// 1111111
Florida's Leading Engineering Source
ILE
COFY
F
1 Enfernrise Drive. Port St. Lucie. Florida 3498(i
NUNN I s V
v
2TFRNAT���P
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION
LUCIE, FL
PERMIT NO.
1404-0068
OWNER
WEATHER
CONTRACTOR
KAST TEMPERATURE
ARCHITECT
WIND
ENGINEER
HUMIDITY
TYPE OF INSPECTION: ROOF TRUSS CONN
MEMBERS/AREA INSPECTED:
TRUSS TO MASONRY CONNECTIONS AT ROOM NO. 157 (PAVILION)
1/ TRUSS GIRDERS #F04G, # F08G
A) DETAILS ARE NEEDED (UPLIFT >2300#)
2/ TRUSS NOS. EJ1 H, EH2H, EJ3H, EH4H, EJ5H, EJ6H, EJ7H
A) DETAILS ARE NEEDED
3/ TRUSS # HJ3F
A) 1-STRAP ONLY
4/ TRUSS NOS. EJ18G, EJ17G, EJ16G, EJ15G, EJ14G, EJ13G.
A) STRAPS ARE MISLOCATED - REMEDIAL DETAILS ARE NEEDED.
5/ TRUSS# EJ12F (NORTH ELEVATION)
A) NO STRAPS
6/ TRUSS # F01
Al 1 -12" STRAP
7/ TRUSS # F02
A)l-16" STRAP
TRUSS TO TRUSS CONNECTIONS (NO EXCEPTION TAKEN)
Disposition of Inspection
Section / Area Approved
Work In Progress
COMMENTS/ACTIONREQUIRED:
[ION
D
APR 2 7 REUD 0
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Thursday, February 19, 2015
S I M I T I W 1TH F S
DAY 19TH
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0023A
LOW
MODERATE
HIGH
X
RX
Re -Inspection
Re -Inspection Required
ANP
Inspection Performed Eta, HIS • L N •• TE' 25��
Inspection Certifiedoy: ;• N k44 4653•;a�z��
* aul H. Danfo
Registered Professionallslo: E. 44653 �r
Certified Special Inspector t1o"1103�.rAT QF :,��
FBPE Certificate N$: Oak ,cc, c�Q:•_�'���
. Construction Materials Testing • Special & Threshold Inspections . Plan Review & Co"yi . RM N A L %'
Florida's Leading Engineering Source 11411 r 1 1 111,,
M y
FILE
CORI
521 Enfer rise Drive, Port St Lucie, Florida 34986
GFA PROJECT # 12-1287.01 RNAT�
PROJECT PGA VILLAGE CLUBHOUSE ADDITION
LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO. 1404-0063
OWNER PGA OF AMERICA WEATHER
CONTRACTOR KAST CONSTRUCTION TEMPERATURE
i
ARCHITECT N/A WIND
ENGINEER N/A HUMIDITY
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Sunday, March 29, 2015
S I M I T I W I TH F S
DAY I X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
BELOW 60
60-75
75-90
ABOVE 90
LOW
MODERATE
HIGH
Report No
0023C
LOW
MODERATE
HIGH
TYPE OF INSPECTION: ROOF TRUSS SUMMARY
MEMBERS/AREA INSPECTED: ITEMIZED TRUSS DEFICIENCIES ARE SHOWN BELOW. THE LOCATIONS
ARE MARKED AND HIGHLIGHTED ON THE ATTACHED ROOF FRAMING PLAN.
REMARKS; RESPONSE TO RFI # 1481-1 AND COPIES OF THE FIELD INSPECTION REPORTS ARE ATTACHED.
2/12/2015
1) FG05 AT SKY LIGHTS - T-BRACES MISSING, (4) LOCATIONS
2) FG04 AT NORTH END ROOM #142 - T-BRACES MISSING
3) FG04 AT SOUTH END ROOM # 140 - T-BRACES MISSING
2/13/2015 - ROOM #124
1) EJ1, EJ3, EJ4 - CLIPS/STRAPS NOT PER SCHEDULE
2) A09G - CLIPS/STRAPS NOT PER SCHEDULE
3) A010 - STRAP (1) SIDE ONLY
4) A01 (4) TRUSSES - STRAPS NOT PER SCHEDULE
5) A05 - T-BRACES NEEDS TO BE RENAILED
6) TRUSS GIRDER A08G - SEE RFI #1481-1
2/19/2015 - TRUSS TO MASONRY WALLS, ROOM # 157 (PAVILION)
1) TRUSS GIRDER FG04G, F08G - SEE RFI #1481-1 ,
2) EJ1H, EJ2H, EJ3H, EJ4H, EJ5H, EJ6H, EJ7H - DETAILS NEEDED
3) HJ3F - (1) STRAP MISSING
4) EJ18G, EJ17G, EJ16G, EJ15G, EJ14G, EJ13G - STRAPS ARE MISALIGNED
- 5) EJ12F (NORTH) - NO STRAPS
6) F01 - (1) 12" STRAP NOT PER SCHEDULE
7) F02 - (1) 16" STRAP NOT PER SCHEDULE
Disposition of Inspection
Section / Area Approved
Work In Progress
c�IEod[E
APR 2 7 HELD D
Rx
Re -Inspection
Re -Inspection Required
Inspection Performed
Inspection Certified
Registered Professional
Certified Special Inspector
C * *
PAIL H.
FBPE Certificate No:
%1 ij
ANI
•YJ3j _ STATE
P.E.
01-
. Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code C.Atee v IV H V
Florida's Leading Engineering Source
flllllll►�
521 Enrerpril nve,E0t.LCueFQ0ra3 P86
v
��rFRNAT�o�P
GFA PROJECT # 12-1287.01
PROJECT PGA VILLAGE CLUBHOUSE
1916 PERFECT DRIVE, PORT ST.
LOCATION LUCIE, FL
PERMIT NO. 1404-0063
OWNER WEAT
CONTRACTOR KAST TEMPERAT
ARCHITECT W
ENGINEER I HUMID
I
TYPE OF INSPECTION: ROOF AND EXTERIOR WALL SHEATHING REVIEW.
HER
URE
IND
ITY
Phone: (772) 489-9989 Fax: (772) 489-2989
GENERAL
INSPECTION REPORT
DATE Thursday, April 09, 2015
S I M I T I W I TH F S
DAY 9TH
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0024
LOW
MODERATE
HIGH
X
MEMBERS/AREA INSPECTED:
JOHN POSTHLETHWAITE, BN 2543, INSPECTOR AT GFA INTERNATIONAL, INC. HAS REVIEWED THE INSPECTION LOG
AS REQUESTED.
I
* THE REPORT DATED 01/02/2015 IS THE FINAL INSPECTION OF THE ROOF SHEATHING. THE ROOF SHEATHING HAS
PASSED.
* THE WALL SHEATHING WAS INSPECTION ON 12/23/2014. THE WALL SHEATHING HAS PASSED.
THESE REPORTS WERE SUBMITTED AT THE TIME ,OF THE INSPECTION.
ADDITIONAL COPIES OF THE AFOREMENTION INSPECTION REPORTS ARE ATTACHED FOR YOUR CONVENIENCE.
I
I
1
Disposition of Inspection
VSection / Area Approved
]Work In Progress
COMMENTS/ACTION REQUIRED:
D [E
APR Z 7 REC'D
Environmental • Geotec
RRe -Inspection
Re -Inspection Required
Inspection Performed By:
Inspection Certified By:
Registered Professional Nor.
Certified Special Inspector NO"
FBPE Certificate No
• Construction Materials Testing • Special & Threshold Inspections • Plan Review & C
(Florida's Leading Engineering Source
I
11111111/
.:44653
:103
8 TAT E O F
pNRA� �tG•.•r\� �
m'o"IL
'�8'x. :� cory
521 Enterprise Drive, Port St. Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE ADDITION
LOCATION
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
i
PGA OF AMERICA
I
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIN13
ENGINEER
N/A I
HUMIDITY
TYPE OF INSPECTION: TRUSS INSPECTION I
MEMBERS/AREA INSPECTED: REVIEWED OUTSTANDING ITEMS AND RFI
REMARKS;
Disposition of Inspection
RSection / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
D CC�G���/CG
APR 2 7 AECD D
RX
Re -Inspection
Re -Inspection Required
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Thursday, April 09, 2015
S M I T W I TH F S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
0025
X
Inspection Performed By:
44
Inspection Certified
Registered Professionaeck
Certified Special InspectoAo:
r -Q
FBPE Certificate%lo3
L..- Environmental • Geotechnical e Construction Materials Testing • Special & Threshold Inspections -Plan Review
i• Florida's Leading Engineering Source
91
# 2543
N6)AWW$Z, P.Er: �r
¢
09.3o STATE OF
rpii#nce✓ f'� �-_�A
SOON A1.���
��//11111111�
FI
Enferp
GFA PROJECT#
PROJECT
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
I, orf SI
�RNAT��
12-1287.01
PGA VILLAGE CLUBHOUSE ADDITION
1
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
1404-0063
PGA OF AMERICA
KAST
N/A
N/A
WEATHER
TEMPERATURE
WINO
HUMIDITY
TYPE OF INSPECTION: TRUSS INSPECTION j
MEMBERS/AREA INSPECTED: CONTINUED REINSPECTION OF ROOF TRUSSES
REMARKS;
I
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Thursday, April 09, 2015
S I M T I W TH F S
DAY X
I
Disposition of Inspection
Section / Area Approved NX
Re -Inspection
Work In Progress Re -Inspection Required
COMMENTS/ACTION REQUIRED:
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0026
LOW
MODERATE
HIGH
X
�Illlllllf/fQ
Inspection Performed TLE IT54
D 44653 ��
Inspection Certified z : ; 4k
APR 2 7 REC'D F.AUL H. D * TH, P.E.
• -
Registered Professional 39o. •E. #44653
Certified Special Inspector lb:lSTATE OF �
FBPE Certificate Noe,' ••'•,`4 0��.•'• ��,
Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code c IN A,
'Florida's Leading Engineering Source
fff1111111
1
GFA PROJECT #
12-1287.01 1
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
TYPE OF INSPECTION: EXTERIOR DOOR /
MEMBERS/AREA INSPECTED: INSPECTED F
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Friday, April 10, 2015
S I M I T I W I TH I F I S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
0027
X
W INSPECTION
ING OF DOOR #141. 156, 157B
REMARKS: REFERENCED DOCUMENTS:
NOA # 12-0117.05 - TRULIGHT 350`
NOA # 11-1117.02 - TRULIOGHT 3100 RESISTOR ALUMINUM STORE FRONT WINDOW WALL SYSTEM
* RESISTOR SERIES MEDIUM STILE IMPACT OUTSWING CURTAIN WALL SYSTEM DOOR
I
Disposition of Inspection
eX Section / Area Approved Re -Inspection
Work In Progress HRe-Inspection Required
COMMENTS/ACTION REQUIRED:
�.- -•i
Inspection Performed By: J �� 3
D Inspection Certified By: Q4ro3 �'ayzz 01
SPA TH, P.E. � �±
APR 2 7 RECD Registered Professional No:P�:#44653 or
Certified Special Inspector No==SfG'k3 U
FBPE Certificate No:
��. A.••. .••
Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Cal & lO w'
Florida's Leading Engineering Source lf�/��„'I,V"/1'����
I
FILE COF-Y
521 Enterprise Drive, Port St. Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
Phone: (772) 924-3575 Fax. (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Friday, April 10, 2015
S M T W TH F S
DAY X
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0028
LOW
MODERATE
HIGH
X
Disposition of Inspection
R Section
/ Area Approved Re -Inspection
Work In Progress Rx Re -Inspection Required
COMMENTS/ACTION REQUIRED:
�/ ,, NF ,,
DE � .IE D V E Inspection Performed BM% !i w # 2543
Inspection Certified Q : �' •••, S' /z015
APR 2 7 RECD , ;% LN.QDA , P.E. * =
Registered ProfessionaiNt. E. 4$653 ,
•
Certified Special Inspectog $I 1103
FBPE Certificate�o(��193o STATE OF w�
Environmental . Geotechnical • Construction'Materials Testing • Special & Threshold Inspections . Plan Review ppW'�1i2„oe. • • • • • •!G_�``v
Florida's Leading Engineering Source ����;; f0N A; ',,`0
FILE
CO-PY
•. . .
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE AC
LOCATION
1916 PERFECT DRIVE, PORT ST.
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
CONTRACTOR
KAST CONSTRUCTION
ARCHITECT
N/A
ENGINEER
N/A
Phone: (772) 924-3575 Fax: (772) 924-3580
CONCRETE PLACEMENT
INSPECTION REPORT
DATE Thursday, February 12, 2015
ON
S M T W TH F S
IE, FL DAY 12TH
WEATHER
TEMPERATURE
WIND
HUMIDITY
MEMBERS/AREA INSPECTED: SIGN FOOTING AND TIE BEAM AT ROOM # 157.
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0020
LOW
MODERATE
HIGH
X
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO NIA
X
1 SPARE VIBRATOR ON HAND
X
2 FORMS WETTED/OILED
X
3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
X
4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
X
5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAY'S POUR
X
6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
X
7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
X
8 SUFFICIENT VIBRATION PERFORMED
X
9 STEEL REMAINED IN PLACE DURING POUR
X
10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
AREA
POURED
YDS
PSI
TYPE MIX
SLUMP
IN ± IN
START TIME
END TIME
METHOD OF
PLACEMENT
SUPPLIER
TIE BEAM &
SIGN FOOTING
5
3,000
#8PM
14:45
15:30
PUMP
TITAN
Disposition of Inspection
MSection / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
DL=-U
APR 2 7 REC'D
Re -Inspection
Re -Inspection Required
Inspection Performed B911.1v Jop
Inspection Certified B2
Registered Professional N PAJ
- P
Certified Special Inspector No!,-5l
FBPE Certificate No: ro.
j111111811,
ANFO -�i�
G N S •'•• ��i
do
412 o E
NFO E.
Environmental • Geotechnical • Construction'Materials Testing • Special & Threshold Inspections • Plan Review & Code ComplrIZA/11111111j1%
Florida's Leading Engineering Source
I
FILE CC--?Y �
521 NW Enterprise Drive, Port St. Lucie, Florida 34986
GFA PROJECT#
12-1287.01
PROJECT PGA VILLAGE CLUBHOUSE ADDITION
LOCATION 1916 PERFECT DRIVE, PORT ST.1 LUCIE, FL
PERMIT NO.
OWNER
1404-0063
PGA OF AMERICA
CONTRACTOR KAST CONSTRU
ARCHITECT
N/A
WEATHER
TEMPERATURE
WIND
ENGINEER N/A HUMIDITY
MEMBERS/AREA INSPECTED: =Re -Inspection
1) HSS 6" X 2" X 1/4, DWG 12/CW4 AT ROOM #124; NORTH (INTERIOR) WALL
a) CONNECTIONS TO LIGGHT GAUGE METAL WALL BELOW IS COVERED
2) W8K20, DWG 13/CW-5 AT ROOM #124, INTERIOR WALL
a) BEAM CONNECTIONS ARE COVERED b) DETAIL 5/S2.2 SHOWS HSS BEAM. II
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED i
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. CAPR
nCOMPLIES �VJYES NO N/AX 1 MILL CERTIFICATION AND TEST REPORTS
X 2 DISTORTION, EXCESSIVE] RUST, BURNED HOLES RECD
X 3 CAMBER
X 4 SIZE, THICKNESS, WEIGHT
X 5 SPLICES
X 6 BOLTS IN ALL BOLT HOLES
X 7 ANCHOR BOLT SIZE, LENGTH, PLUMBNESS, EMBEDMENT, THREAD PROJECTION
X 8 HIGH TENSILE BOLT SIZE', LENGTH, TYPE, WASHERS, NUTS
X 9 BOLT TORQUEING
X 10 COLUMN ALIGNMENT, BASE PLATE SIZE AND FIT
X 11 GROUTING OF BASE PLATES
X 12 BAR -JOIST SIZE, SPACING, BEARING, CONDITION
X 13 BAR -JOIST BRIDGING AND BRACING
X 14 CORRUGATED ROOF DECK GAUGE, CONDITION, SIDE AND END LAPS
X 15 HEADED STUDS PLACEMENT AND WELDING
DISPOSITION OF INSPECTION:
=Section / Area Approved =Work In Progress EIRe-Inspection Required
c.
Phone: (772) 924-3575 Fax. (772) 924-36
STRUCTURAL STEEL
INSPECTION REPORT
DATE Friday, April 10, 2015
S M T W TH F S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
X
Report No
LOW
MODERATE
HIGH
X
0029
COMMENTS / ACTION REQUIRED: MEMBERS AND CONNECTIONS ARE COVERED, BOTH SI
Inspection Performed By: ,� /'OS T I , Bl%hu
On Site I Inspection Certified By:: * adz/zo7s
§ -PAll; H. DANFORTH, P.E.
Off Site P , Registered Professional No: ;.� 465 �:
� e
Travel Certified Special Inspector No: Sr7 ••tic(„ P.' ���`
form revised 11/21/06 Total Hours =>g' FBPE Certificate No: 4930��i S/ AI A I •F� k
Environmental a Geotechnical a Construction Materials Testing a Special & Threshold Inspections a Plan Review & Code Compliance
Florida's Leading Engineering Source
FILE
COFY
521 Enterprise Drive, Port St Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
i
HUMIDITY
TYPE OF INSPECTION: LIGHT GAUGE METAL FRAMING
MEMBERS/AREA INSPECTED: LIGHT GAUGE STUD FRAMING, ROOM #124
REMARKS; a) WALL IS COVERED BOTH SIDES, CANNOT INSPECT
b) REQUIRED SHOP DRAWING SUBMITTAL NOT AVAILABLE FOR INSPECTION
I
I
Disposition of Inspection
Section / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
APR 2 7 OECD D
Phone: (772) 924-3575 Fax. (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Friday, April 10, 2015
S M T W TH IF
DAY X
Rx
Re -Inspection
Re -Inspection Required
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0030
LOW
MODERATE
HIGH
X
Inspection Performed By: JI
Inspection Certified By:
R
Registered Professional No: I:
Certified Special Inspector No:
FBPE Certificate No:
Environmental • Geotechnical e Construction;Maledals Testing . Special & Threshold Inspections . Plan Review &
Florida's Leading Engineering Source
t44653'A0 44653 •�
T• STATF arm
O R 1 �. •G\,��
�i��i'�p1V
FILE COF'7
i
521 Enterprise Drive. Port St Lucie. Florida 34986
GFA PROJECT#
PROJECT
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
12-1287.01
PGA VILLAGE CLUBHOUSE ADDITION
1916 PERFECT DRIVE. PORT ST. LUCIE. FL
PGA OF AMERICA WEATHER
KAST CONSTRUCTION TEMPERATURE
N/A WIND
N/A HUMIDITY
TYPE OF INSPECTION: ROOF TRUSS
MEMBERS/AREA INSPECTED: ROOM #157
REMARKS:1) TYPICAL
a) HSTM20 STRAPS, (4) TAPCONS IN CONCRETE, SPECED 1" O.C.
b) HSTM 20 STRAPS ARE NOT APPROVED
c) BRACING IS INCOMPLETE
Disposition of Inspection
Section / Area Approved Re -Inspection
Work In Progress Rx Re -Inspection Required
COMMENTS/ACTION REQUIRED:
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Monday, April 13, 2015
S I M I T W I TH I F I S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0031
LOW
MODERATE
HIGH
X
22 _�%f_( �_ _ I I I I IIIOI
D-- L � � [a U �:/ L�
Inspection Performed By: J • . .I �, 43
Inspection Certified By: �•�'A t/� s
APR 2 7 REUD H. D .
Registered Professional Nd: P. :#44653
Certified Special Inspector NCEW 0 • p-
3iAiE OF lV
FBPE Certificate No:lzw..
Environmental • Geotechnical • ConstructionMaterials Testing . Special & Threshold Inspections • Plan Review & Code dg, j • • • • • • • •' •w` ��
Florida's Leading Engineering Source �I��,ONA; 11%`,���,,
I
�'ILE
COFY
521 Entervrise Drive. Port St. Lucie. Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
CONTRACTOR
KAST CONSTRUCTION
ARCHITECT
N/A
ENGINEER
N/A
TYPE OF INSPECTION:
ROOF TRUSS
MEMBERS/AREA INSPECTED: ROOM #157
WEATHER
TEMPERATURE
WIND
HUMIDITY
Phone: (772) 924-3575 Fax: (77? 924-3580
GENERAL
INSPECTION REPORT
DATE Tuesday, April 14, 2015
S I M I T I W I TH F S
DAY X
REMARKS;
1) TRUSS F04G TO CONCRETE WALL
a) UPLIFT OF 3735 AND 3736 SHOWN ON TRUSS DWG. ENGINEER TO ADVISE
2) TRUSS EJ4H TO F08G
a) THAR 29
b) NAILS MISSING
3) EJ6H TO F04G - TOE NAILING SHOWN THAR 29 USED
4) EJ5H TO F04G, THAR 429 SHOWN THAR 29 USED. NAILS MISSING
5) HJ3F TO F08G
a) OK
I
GENERAL NOTES:
1) TRUSS DWG SHOWS THAR 29
a) NOT LISTED IN TRUSS HANGER SCHEDULE
2) HJ3F TO F08G, TRUSS DWG SHOWS THAR 429, NOT ON SCHEDULE
Disposition of Inspection i
Section / Area Approved Re -Inspection
Work In Progress Rx Re -Inspection Required
COMMENTS/ACTION REQUIRED:
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0032
LOW
MODERATE
HIGH
X
1111 11111 ,
DA
� �/�(���__ Inspection Performed By: cb� t} IDf 2543.IE Inspection Certified B�♦ F••. � ms
LL H. E.•: 0
Registered Professional Flo: I?E. 4653
APR 2 7 RECD
Certified Special Inspector 11;�O 1103
FBPE Certificate hPo •3p TgTE OF '
Environmental _G qotechnical • Construction Materials Testing • Special & Threshold Inspections . Plan Review & 00%. • ....G•
Florida's Leading Engineering Source ��I /ON AL
lillllll,,
R.
■
521 Enterprise Drive, Port St.
�� y
Florida 34986
GFA PROJECT # 12-1287.01
PROJECT PGA VILLAGE CLUBHOUSE ADDITION
LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE. FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMER]
CONTRACTOR
KAST CONSTRUC
ARCHITECT
N/A
ENGINEER
N/A
TYPE OF INSPECTION:
ROOF TRUSS
MEMBERS/AREA INSPECTED: ROOM #127 AND
REMARKS;
ROOM #127
1) GIRDER F09G TO CONCRETE
a) OK PER RFI #1481-1, ITEM #1
2) GIRDER F04G
a) UPLIFT > 2300 LBS - FOR TO ADVISE
BRACING
INSPECTION
ROOM #124
#124
WEATHER
TEMPERATURE
WIND
HUMIDITY
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Tuesday, April 14, 2015
S M T W TH F S
DAY X
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
0033
X
1) TRUSS FG01
a) DOUBLE TRUSS, NO GANG NAILING AT TOP CHORD, BOTTOM CHORD AND WEBS
2) A08G AT FG01
a) STRAPS PER RFI #14-1481-1, ITEM #4 - OK
3) TRUSS A09G TO INTERIOR WALL
Disposition of Inspection
Section / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
DIg,�-VL=U W Lc. -
APR 2 7 RECD
Rx
Re -Inspection
Re -Inspection Required
Inspection Performed By:
Inspection Certified By k
•H
Registered Professional N(i P41
Certified Special Inspector Noa,0103
FBPE Certificate No: $93t
IITFI, P.E.
• r
Environmental . Geotechnical • Constructionl`Materials Testing . Special & Threshold Inspections . Plan Review & Code C�I' c�O I� 1 ^ `�
iFlorida's Leading Engineering Source � III I100%
I
_� � LE CC-4.)Y
521 Enterprise Drive, Port St. Lucie, Florida 34986
GFA PROJECT # 12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE ADDITION
LOCATION
1916 PERFECT DRIVE, PORT ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
CONTRACTOR
KAST CONSTRUCTION
ARCHITECT
N/A
I
ENGINEER
N/A
I
WEATHER
TEMPERATURE
WIND
HUMIDITY
TYPE OF INSPECTION:
MEMBERS/AREA INSPECTED:
1) RFI #55, ROOM #152A -142
a) 2K4 STUD FRAMING IS NOT COMPLETED BLOWI2-21<12 LEDGER
b) 2K6 BLOCKING BETWEEN TRUSSED, NOT IN PLACE
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Wednesday, April 15, 2015
S M T W TH F S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0034
LOW
MODERATE
HIGH
X
c) SECTION 10/S2.2 SHOWS TRUSSES CONNECTED TO CONCRETE WALL. TRUSSES ARE CONNECTED TO THE LEDGER *
2) RFI #73
a) INSPECTED FRAMING PER RFI #73, APPROVED COPY RFI IS PENDING
3) LIGHT GAUGE METAL FRAMING
a) INSPECTED FRAMING PER STRUCTURAL DRAWINGS, SHOP DRAWINGS ARE PENDING **
4) EXTERIOR WINDOW ATTACHMENT
a) COMPLETED
5) EXTERIOR DOORS
a) EXTERIOR DOORS NOT INSTALLED 15015, 14713,1131A, 1316, 126A **
b) STORE FRONT DOOR COMPLETED
6) SCREEN WALL
a) 1-THRU BOLT MISSING **
I
Disposition of Inspection
X Section / Area Approved ** Re -Inspection
Work In Progress Re -Inspection Required
COMMENTSIACTION REQUIRED:
DA
APR 2 7 HELD
Inspection Performed By: m
Inspection Certified By:Z
Registered Professional No:
Certified Special Inspector No:
FBPE Certificate No:
WAR
4/z2/2ti._
ANFO H, P.E.
HAARF3 _ _ — — • .
Environmental . Geotechnical .
Materials Testing • Special & Threshold Inspections . Plan Review & Code Compliance' 111
Florida's Leading Engineering Source
FILE
COP
521 Enterprise Drive, Port St Lucie, Florida 34986
GFA PROJECT#
PROJECT PGA VILLAGE
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
12-1287.01 !
1916 PERFECT DRIVE
TYPE OF INSPECTION:
MEMBERS/AREA INSPECTED:
7) TRUSS ENGINEERING
a) COMPLETED
1404-0063
Phone: (772) 924-3575 Fax. (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Wednesday, April 15, 2015
ADDITION
S I M I T W TH F S
ST. LUCIE, FL DAY X
PGA OF AMERICA WEATHER
i
KAST CONSTRUCTION TEMPERATURE
I
N/A WIND
N/A HUMIDITY
8) TRUSS CONNECTIONS
a) F04G AT ROOM #154 AND 125 UPLIFT > 2300 LBS - FOR TO COMMENT
L % Cnnfl AT rW%r%hA 40A / IIITrIJCAI In1rnnAol CTC *
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0035
LOW
MODERATE
HIGH
X
c) TRUSS STRAPS HSTM20 USED IN LOCATIONS WHERE EMBEDDED STRAPS ARE MISALIGNED
9) STRUCTURAL STEEL
a) 3-GIRDERS WITH HSS BEAM RUNNING PARALLEL, CLIPS FOR TRUSS ATTACHMENT APPROVED BY FOR (EMAIL
DATED 4/14/15, ITEM #1)
10) BRACE DETAILS, 12/S2.3, G/2.4 **
a) BOLTS AND ANCHORS ARE HOT DIP GALVANIZED, DRAWING NOTES SHOW STAINLESS STEEL
b) TOE NAILING, TRUSS TO BEAM, NOT COMPLETED
c) L 6X4X5/16" (12/S2.3), NOT COMPLETED
d) WEDGE ANCHORS USED IN LIEU OF EPOKIED ANCHORS
Disposition of Inspection
Section / Area Approved PIRe-Inspection
Re-Inspection
eWork
In Progress Required
COMMENTS/ACTION REQUIRED:
U�
APR 2 7 HECp
Inspection Performed By: JGfj,1 GPSTL T TE, N #.2gd3-..
Inspection Certified By: v * . 53 41221
&UL ti. kFORT*, P.E.
Registered Professional No: P;E-.914653 ' 0-
STATE OF k/e
Certified Special Inspector No: Sri ,•._• Z
FBPE Certificate No: 493V,' R 1 �.•'�-„� ���
Environmental • Geotechnical
Materials Testing e Special & Threshold Inspections . Plan Review & Code Compliancgl f j j
Florida's Leading Engineering Source
2r��'
IE CO�I�Y
521 Enterprise Drive, Port St. Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
I
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
TYPE OF INSPECTION: TRUSS BRACING
MEMBERS/AREA INSPECTED: 1) REINSPECTED TRUSS BRACING
a1 REPAIRS HAVE BEEN COMPLETED '
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Thursday, April 16, 2015
S I M I T I W I TH I F I S
DAY X
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
0036
X
i
I
Disposition of Inspection.
PSection / Area Approved X Re -Inspection
Work In Progress Re -Inspection Required
COMMENTS/ACTION REQUIRED:
Ld
D Inspection Performed By OH O BIf•# 25
".*.p
Inspection Certified Bye * 4/l /20hF
[E:(dD �PAI� H. DA P.E. �+
Registered Professional NorP . 5 f
•
Certified Special Inspector No: %�3. k ,
FBPECertificate No: 49 s••''••C-•''••• ��♦
Environmental 9 Geotechnical e Construction Materials Testing . Special & Threshold Inspections • Plan Review & Code Compliance-1111111
Florida's Leading Engineering Source ..
b
FILE
5211 Drive, Port St !
GFA PROJECT#
PROJECT
LOCATION
PERMIT NO.
OWNER
CONTRACTOR
ARCHITECT
ENGINEER
Phone: (772) 924-3575 Fax. (772) 924-3580
GENERAL
INSPECTION REPORT
12-1287.01
DATE Tuesday, April 21, 2015
PGA VILLAGE CLUBHOUSE ADDITION
S M T W TH F S
1916 PERFECT DRIVE, PORTI ST. LUCIE, FL DAY 21ST
1404-0063
1
WEATHEP
TEMPERATURE
WINC
HUMIDITY
PGA OF AMERICA
I
KAST CONSTRUCTION
N/A
N/A
TYPE OF INSPECTION: REINSPECTIONS
BRIGHTSUN
CLEAR
OVERCAST
RAIN
BELOW 60
60-75
75-90
ABOVE 90
LOW
MODERATE
HIGH
Report No
LOW
MODERATE
j ",IGH0037
MEMBERS/AREA INSPECTED:
1/ TRUSS ATTACHMENT TO STEEL GIRDER (ITEM NO. 1) THAT ARE ATTACHED TO CLIPS PLACED PARALLEL TO TRUSSES
APPROVED BY ENGINEER OF RECORD - SEE EMAIL FROM MATT LOWE, P.E. DATED 04/14/2015 - PASS.
2/ ITEM NO. 3, EMAIL DATED 04/14/2015 I
A) THE HGAMIOKTA CONNECTORS HAVE BEEN ADDED PER ENGINEER OF RECORD RESPONSE - PASS.
3/ ITEM NO. 4, EMAIL DATED 04/14/2015
A) FOOTING FASTENED PER SIMPSON TABLES - PASS.
4/ TRUSS CONNECTION, A09G AT ROOM # 124, RFI I# 1481-1, ITEM NO. 2.
A) SIMPSON VGT CONNECTOR INSTALLED - PASS.
B) SEE ENGINEER OF RECORD COMMENTS REGARDING ADDITIONAL STUD FRAMING REQUIRED. SHOP DRAWINGS
ARE PENDING. SEE EMAIL DATED 04/15/2015 FROM ENGINEER OF RECORD, ITEM NO.2 - INCOMPLETE.
Disposition of Inspection
NSection / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
eRe-inspection
Re -Inspection Required
ITEMS 1, 2,3 AND 4.A - PASS. `ITEM # 4.B IS PENDING. ��♦����� n
♦ '; A
APR 2 7 !10
No 465
Inspection Perfo&db y: JOHN OS THWAjT W # 2543
Inspectio y: 41241201.
WAIf eAIjIF.ORTH� F .-
6 tu! FF � ��
Registered Professiag��l'o� 44653 •
Certified Special Inspect&®�+f•1.3R p••;��� ���
FBPE Certificate No!t NALE7j%%S
• Construction Materials Testing • Special & Threshold Inspections e Plan Review & Code Compliance
Florida's Leading Engineering Source
521 Enterprise Drive, Port St Lucie, Florida 34986
GFA PROJECT #
12-1287.01
PROJECT
PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION
1916 PERFECT DRIVE, PORIj
ST. LUCIE, FL
PERMIT NO.
1404-0063
OWNER
PGA OF AMERICA
WEATHER
CONTRACTOR
KAST CONSTRUCTION
TEMPERATURE
ARCHITECT
N/A
WIND
ENGINEER
N/A
HUMIDITY
TYPE OF INSPECTION: REINSPECTION --SKYLIGHT CURBS
MEMBERS/AREA INSPECTED:
5/ REINSPECT SKYLIGHT CURBS.
ADDITION STRAPS WERE ADDED PER DRAWING.
Disposition of Inspection
Section / Area Approved
Work In Progress
COMMENTS/ACTION REQUIRED:
Phone: (772) 924-3575 Fax. (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Tuesday, April 21, 2015
S M T W TH F S
DAY 21 ST
BRIGHT SUN
CLEAR
OVERCAST
RAIN
BELOW 60
60-75
75-90
ABOVE 90
LOW
MODERATE
HIGH
Report No
0037A
LOW
MODERATE
HIGH
I
11KIRe-inspection
Re -Inspection Required
%H t DAN/`
LE J `r t Inspection Performed Bg Jq N POSTLE H ITE, BN
D Inspection Certified Bye _1
APR 2 7 REUD
Registered Professional No. PV*RP:•••.•:• p.
Certified Special Inspector No: SI
FBPE Certificate No: 4930 ���111111111,,
Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance
Florida's Leading Engineering Source
521 Enterprise Drive, Port St. Lucie, Florida 34986
�HNAT1�'
GFA PROJECT # 12-1287.01
PROJECT PGA VILLAGE CLUBHOUSE
ADDITION
LOCATION 1916 PERFECT DRIVE, PORT
ST. LUCIE, FL
PERMIT NO. 1404-0063
OWNER PGA OF AMERICA
WEATHER
CONTRACTOR I(AST CONSTRUCTION
TEMPERATURE
ARCHITECT N/A
WINE
ENGINEER N/A
HUMIDITY
TYPE OF INSPECTION: REINSPECTIONS
Phone: (772) 924-3575 Fax: (772) 924-3580
GENERAL
INSPECTION REPORT
DATE Tuesday, April 21, 2015
S M T W TH F S
DAY 21 ST
BRIGHTSUN
CLEAR
OVERCAST
RAIN
X
X
BELOW 60
60-75
75-90
ABOVE 90
X
LOW
MODERATE
HIGH
Report No
X
0037E
LOW
MODERATE
HIGH
X
MEMBERS/AREA INSPECTED:
RECEIVED APPROVED DETAIL, DATED 04/20/2015 REGARDING MASONRY TIE-IN AT ROOM # 124/125.
1
RECEIVED APPROVED DETAIL FOR THE WALL FRAMING AT VESTIBULES.
I
R; ; wran ; ' ; t. ig
t v
Disposition of Inspection
Section / Area Approved Re -Inspection
eWork
In Progress HRe-Inspection Required
COMMENTS/ACTION REQUIRED:
_ 4�0/NPOST
•, y
Inspection Performed BE a$, 13 P-* 250
Inspection Certified EW:�J2#2S
EORTH, P.E.APR 2 7 RECD Registered Professional N6T� OF
Certified Special Inspector No: �Vidb;T C-O R I p P'.•������,
... '"�
FBPE Certificate No: 493� �,,_ NA L
EnvironmeMaT•-Geotechnical yconstruction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance
IFlorida's Leading Engineering Source