HomeMy WebLinkAboutConcrete Inspection Report� *ham 4� . -�, •�� !�� ' w.r GFA PROJECT# 12-1287.01 �KNA1►" PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY Phone: CONCRETE PLACEMENT INSPECTION REPORT DATE Tuesday, November 25, 2014 S M T W TH F S DAY 25TH BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0006A LOW MODERATE HIGH IG MEMBERS/AREA INSPECTED: MASONRY WALLS, FILL CELLS (1ST 10 YARDS PLACED IN SI THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X 1 SPARE VIBRATOR ON HAND X 2 FORMS WETTED/OILED X (1) 3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW) X 4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW) X 5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAY'S POUR (2) 6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME X 7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET X 8 SUFFICIENT VIBRATION PERFORMED X 9 STEEL REMAINED IN PLACE DURING POUR X X 10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS AREA POURED YDS PSI TYPE MIX SLUMP IN # IN START TIME END TIME METHOD OF PLACEMENT SUPPLIER MASONRY SILLS 10 3,000 #8PM 5-7 7:50 8:45 PUMP TITAN FILL CELLS 10 3,000 M6-C 10:00 10:30 PUMP TITAN FILL CELLS 10 3,000 M6-C 11:15 12:00 PUMP TITAN TIE BEAM 10 3,000 #8PM 5-7 14:00 15:30 1 PUMP TITAN TIE BEAM 10 3,000 #8PM 5-7 16:00 17:30 1 PUMP TITAN FILL CELLS 11 1 3,000 1 M6-C 18:00 19:30 1 PUMP TITAN Disposition of Inspection [Z]Section / Area Approved Work In Progress COMMENTS/ACTION REQUIRED AT 8:20 AM. Re -Inspection Re -Inspection Required 10 GALLONS ADDED PRIOR TO PLACEMENT (8:00 r Inspection Performe yy dbHN 7y: Inspection Certifi By:; .PAS LILH.' Registered Professionv N "T.E. #44E ap • r�l APR 2 7 RECD Certified Special Inspector1j(0 11 3 •. FBPE Certificate Nis ••. Environ ental . Geotechnical . Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code Co Florida's Leading Engineering Source ADDED ITE, VN GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0063 OWNER WEATHER CONTRACTOR KAST TEMPERATURE ARCHITECT WIND ENGINEER HUMIDITY TYPE OF INSPECTION: REVIEW OF FOUNDATIONS CAST MEMBERS/AREA INSPECTED: ITEMS NOT INSPECTED BY GFA Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Thursday, October 30, 2014 S M T W TH F S DAY x BRIGHTSUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No 1 LOW MODERATE HIGH REMARKS: 1. RECEIVED COPIES OF MIX DESIGNS, KAST SUBMITTAL #1, 9/12/2014 * a) NOT STAMPED BY FOR 2. REVIEWED PHOTO'S OF FOOTINGS PRIOR TO CONCRETING a) PHOTOS BY CONTRACTOR, TIME/DATE STAMP 10/10/2014. b) RECEIVED COPIES OF CONCRETE DELIVERY TICKETS, FOR 20 YARDS OF 3500 PSI, MIX #SW7B5R30 (FOOTING MIX) 10/10/14 3. PREVIOUS CONCRETE POURS 10/3/14 FOOTINGS 20 YDS. #SW7B5R30 10/10/14 FOOTINGS 20 YDS. #SW7B5R30 10/17/14 FOOTINGS 10 YDS. #SW7B5R30 10/24/14 CELL FILL 10 YDS JAG (ILLEGIBLE) CMG Disposition of Inspection Section / Area Approved Re -Inspection Work In Progress RX Re -Inspection Required COMMENTS/ACTION REQUIRED: 1) PHOTOS INDICATE CORRECT REINFORCEMENT; ANCHOR BOLTS (J-BOLTS) EXTEND TO BOTTOM REINFORCED MAT 2 CONCRETE TICKETS INDICATE THE CORRECT MIX # "a Inspection Performed By: , Inspection Certified B`♦ : �� %: 4015 I H. ; • Registered Professional 11: P . #_ 53 IE0IE 0ML :1 .Im is Certified Special Inspector �o: 1 03 FBPE Certificate N1a: �10 pT� C .� Envi e t • Geotechnical . Construction Materials Testing . Special & Threshold Inspections .Plan Review 8 YMoce Q `•� �� ,,�i Florlda's Leading Engineering Source GFA PROJECT # PROJECT LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER 12-1287.01 PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LUCIE, FL 1404-0008 KAST WEATHER TEMPERATURE WIND HUMIDITY S Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Wednesday, January 14, 2015 S M T W TH F S DAY 14TH BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0014 LOW MODERATE HIGH X TYPE OF INSPECTION: WINDOW ANCHORING. MEMBERS/AREA INSPECTED: SEVEN (7) MARK',C' WINDOW FRAMES AND ONE (1) MARK'157A' TRU LITE RESISTOR 350 STOREFRONT DOOR NOA# 12-0117.05. THREE (3) WINDOWS AT RESTAURANT (ROOM NO. 111), FOUR (4) WINDOWS AT BANQUET ROOM (#154) - DOOR AT BANQUET ROOMS. REMARKS; SEE ATTACHED PLAN FOR LOCATIONS. Disposition of Inspection NSection / Area Approved Re -Inspection Work In Progress RRe-Inspection Required COMMENTS/ACTION REQUIRED: Inspection Performed By: JO kRl 1w t1j!43 Inspection Certified By: Its,5 onal W.IAq . • Registered Professional N • P/F;•6067 4653 •. a� —T Certified Special Inspector Ni N// * e FBPE Certificate N4�3�GTA-rE Environme tVtruechnical .Consction Materials Testing -Special & Threshold Inspections -Plan Review & c%101iaro� O R ` p P•i \�,�� APR 2 7 RECtD Florida's Leading Engineering Source ,0 2 . SS, ..... • �,�� .,���iO N A' t v 7 EAI -' .1�f � • GFA PROJECT # PROJECT LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER 12-1287.01 PGA VILLAGE CLUBHOUSE ADDITION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL 1404-0063 PGA OF AMERICA WEATHER KAST CONSTRUCTION' TEMPERATURE N/A WINO N/A HUMIDITY Phone: (772) 924-3575 Fax: (772) 924-3580 REINFORCING STEEL INSPECTION REPORT DATE Tuesday, February 10, 2015 S M T W I TH F S DAY 10TH BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH 0018 X X MEMBERS/AREA INSPECTED: 1) SIGN FOOTINGS AT ENTRANCE (REFERENCE DRAWINGS H1.2). 2) NEW TIE BEAM OVER DOORWAY BETWEEN ROOM NOS. 157-158. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X 1 SOIL BEARING CAPACITY X 2 BUILDING LOCATION X 3 BUILDING SLAB ELEVATION X 4 TERMITE TREATMENTVERIFIED X 5 COMPACTION TESTING X 6 FORMING DIMENSIONS X 7 INSIDE OF FORMS CLEAN X 8 WIRE MESH REINFORCING SIZE AND LAP X 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING X 10 SPLICES X 11 REBAR CLEAN AND FREE OF OIL X 12 REBAR CLEARANCE FROM FORMS AND EARTH X 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED X 14 SHORING AND RE -SHORING X 15 POST TENSIONED CABLE LAYOUT AND PROFILE Disposition of Inspection X Section / Area Approved Re -Inspection RRe-Inspection Work In Progress Required COMMENTS/ACTION REQUIRED: APR 2 7 OECD D Inspection Performed Inspection Certified Bya Registered Professional No Certified Special Inspector No: FBPE Certificate No: �-ITV i rr__ : \ �i r�PO LE a, BIB,# 954k 4122 4 H. D ORTH, PbF �#4465 T T Eft • Construction Materials Testing • Special & Threshold Inspections . Plan Review & Code Compliance Florida's Leading Engineering Source FILE COPY 521 Enterprise Drive, Port St Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT i PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0063 OWNER WEATHER CONTRACTOR KAST TEMPERATURE ARCHITECT WIND ENGINEER HUMIDITY Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Wednesday, February 11, 2015 S M T W TH F S DAY 11TH BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0019 LOW MODERATE j HIGH X TYPE OF INSPECTION: PARTIAL TRUSS ENGINEERING (ONLY). MEMBERS/AREA INSPECTED: TRUSS ENGINEERING IN ROOM # 157 (PAVILION), ROOM # 156 (ANTI ROOM), ROOM # 158 (PATRON TERRACE). OBSERVATIONS: 1) ROOM # 158 A) RAT RUN AT EAST END OF TRUSS NOS. B01 IS NOT CONTINUOUS. B) WEB BRACES AT WEST END ARE MISSING. C) TRUSS # MT 01, (2) PLY TRUSS, BOTTOM CHORD NAILING IS NOT PER DETAIL AT CENTER. 2) ROOM # 157 Disposition of Inspection RX Section / Area Approved Re -Inspection Work In Progress RX Re -Inspection Required COMMENTS/ACTION REQUIRED: Inspection Performed By: �•IVfa ��� Inspection Certified BY,$ 653 4!i tfls P H. Da ort, . R nEO0 Registered Professional IN 44653 I v Certified Special Inspector N y •103 • STA ; FBPE Certificate NOK *. a ? .• • Geotechnical • Construction Materials Testing • Special & Threshold Inspections e Plan Review & Cod • •;•:;n^` • &•- Florida's Leading Engineering Source ���� /O N y '01I/11111111 521 NW GFA PROJECT# Port St Lucie. Florida 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0008 OWNER PGA OF AMERI CONTRACTOR KAST CONSTRUCTION ARCHITECT N/A Phone: (772)924-3575 Fax: (772) 924-3580 TRUSS ENGINEERING AND SHEATHING INSPECTION REPORT WEATHER TEMPERATURE WIND DATE Thursday, February 12, 2015 S M T W TH F S DAY 12TH ENGINEER N/A HUMIDITY MEMBERS/AREA INSPECTED: TRUSS ENGINEERING AT ROOM NOS. 126A, 126B, 127A, 127B, 128, 129, (130- 140), (142-151), 152, 155. BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH X Report No MODERATE HIGH PO-W7 0021 X COMMENTS: 1) FG05 IA ST SKYLIGHTS, (4) TRUSSES, T-BRACES MISSING. 2) (2) FG04 IS AT NORTH END ROOM # 142 AND SOUTH END ROOM # 140. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X 1 APPROVED TRUSS ENGINEERING SHOP DRAWINGS ON SITE (1) 2 TRUSS ENGINEERING (SCAB BRACES, T-BRACES, L-BRACES, CLB) X 3 BOTTOM CHORD BRACING X 4 GABLED END BRACING X 5 UPLIFT (STRAPS(no slack for movement), BUCKETS, NAILS, BOLTS) X 6 REACTIONS (BUCKETS; COLUMNS, BEARING, NAILS, BOLTS) X 7 WEBS, TOP CHORDS, BOTTOM CHORDS AND JOINTS ARE NOT BROKEN, CUT OR DAMAGED X 8 PLACEMENT OF TRUSSES X 9 BEARING WALL FRAMING (SIZE, SPACING, STRAPS, NAILS, BOLTS) X 10 WOOD SEPARATED FROM CONCRETE OR MASONRY X 11 PLACEMENT AND THICKNESS OF SHEATHING X 12 NAILING OF SHEATHING X 13 REMOVAL OF SHINERS X 14 CONDITION OF SHEATHING X 15 BLOCKING OF SHEATHING AT GABLED ENDS X 16 PLACEMENT OF FIRE RATED SHEATHING M ion of Inspection Section / Area Approved Rx Re-Inspection Work In Progress Re -Inspection Required COMMENTS / ACTION REQUIRED: -- - -- —� �. •..- E N-...•,�, rN II V� U Inspection Performed By. CO T ET BN#.25 D �. Inspection Certified Byr ,k w 414 Pau;H. Danforth, P*. APR 2 7 RECD Registered Professional Nos• P.E• 44653 : Certified Special Inspector No 1�-1. STAGE OF ; _�. form revised 9/21/06 FBPE Certificate No: � 0�':c� 0 R Environmental : Geotechnical • Construction Materials Testing . Special & Threshold Inspections e Plan Review & Code A6 ce �� Florida's Leading Engineering Source 4,/11111:10 FILE COP"- 521 Enterprise Drive. Port St Lucie. Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0063 OWNER WEATHER CONTRACTOR KAST TEMPERATURE ARCHITECT WIND ENGINEER HUMIDITY Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Friday, February 13, 2015 S I M T I W TH F S DAY 13TH BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No 0022 LOW MODERATE HIGH TYPE OF INSPECTION: TRUSS (PARTIAL) MEMBERS/AREA INSPECTED: INSPECT CLIP INSTALLTION FOR TRUSS TO MASONRY CONNECTIONS, ROOM # 124 (MEMBER DINING). COMMENTS: 1) TRUSS NO. EA, EJ3, EJ4 A) CLIPS ARE NOT PER FASTENED SCHEDULE. 2) TRUSS GIRDER A09G A) CLIPS ARE NOT PER FASTENED SCHEDULE, STRAP 1-SIDE ONLY. 3) TRUSS #A10 A) CLIPS ARE NOT PER SCHEDULE - STRAP 1-SIDE ONLY. 4) TRUSS #A01 A) 6 - TRUSSES, CLIPS NOT PER SCHEDULE. STRAPS ARE 1-SIDE ONLY WITH TWIST STRAPS OPPOSITE SIDE TAPCON ANCHORS INTO CONCRETE. 5) TRUSS A04 A) T-BRACE NEEDS TO BE RENAILED. 6) TRUSS GIRDER # A08G A) 13 #10 NAILS USED WHERE 18 #10 ARE REQUIRED (DETA20) 7) TRUSS #HJ5A A) CLIP IS NOT PER SCHEDULE, EMBEDDED STRAP 1-SIDE, TWIST STRAP OTHER SIDE. Disposition of Inspection Section / Area Approved Re -Inspection Work In Progress RX Re -Inspection Required COMMENTS/ACTION REQUIRED: D n APR 2 7 OECD II w Environmental • Gf Inspection Performed By: Inspection Certified BF. Registered Professional l�b� Certified Special Inspector Igo: FBPE Certificate Nb: • construction Materials Testing • Special & Threshold Inspections • Plan Review Florida's Leading Engineering Source E. 44653 110 Imo STATE OF wh 0 Ft : 9/ONA, r � • o �o A It k. WSnNo.�NS�� 1 PROJECT PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0068 OWNER WEATHER CONTRACTOR KAST TEMPERATURE ARCHITECT WINE) ENGINEER HUMIDITY TYPE OF INSPECTION: ROOF TRUSS CONNECTIONS MEMBERS/AREA INSPECTED: Phone: (772) 489-9989 Fax. (772) 489-2989 GENERAL INSPECTION REPORT DATE Thursday, February 19, 2015 S M I T I W 1TH F I S DAY 19TH BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0023 LOW MODERATE HIGH X TRUSS TO MASONRY CONNECTIONS AT ROOM NO. 125 (MEMBER BAR) 1/ TRUSS #F09G, #F04G A) DETAIL NEEDED (UPLIFT >2300#) 2/ TRUSS #H2JK, A) NO EMBEDDED STRAPS B) (1) TWIST STRAP USED (ANCHORING TO CONCRETE IS (4) TAPCONS AT 1" O.C.) 3/ TRUSS # Hi F, (WEST) A) (1) 16" STRAP (2 REQUIRED) 4/ TRUSS # CJ3F (EAST OF #HJ1 F) A) (1) 16" IN LIEU OF (2) 12" STRAPS 5/ TRUSS #EJ1 OF A) LESS THAN (10) NAILS 6/ TRUSS # HJ2F A) (1) 16" STRAP (2 REQUIRED) TRUSS TO TRUSS GIRDER CONNECTIONS AT ROOM # 125 (NO EXCEPTION TAKEN). Disposition of Inspection Section / Area Approved Re -Inspection Work In Progress RX Re -Inspection Required COMMENTS/ACTION REQUIRED: Inspection Performed By-, Inspection Certified Bg E(� 2 O �l/ f� Registered Professional 4: . L� V L5 Certified Special Inspector N FBPE Certificate Nor Geotechnical • Construction Materials Testing • Special & Threshold Inspections . Plan Review & Florida's Leading Engineering Source %%"tJ11111111 ANF • _ N0 53 4!�'-VS II H. Danforth, P.E. E. 44653 1103in EW O N P►L �//1111111� GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION. TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY MEMBERS/AREA INSPECTED: SIGN WALL (14/H1 Phone: (772) 924-3575 Fax: (772) 924-3580 REINFORCING STEEL INSPECTION REPORT DATE Tuesday, March 03, 2015 S I M I T I W I TH I F I S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH j 0023B X THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X 1 SOIL BEARING CAPACITY X 2 BUILDING LOCATION X 3 BUILDING SLAB ELEVATION X 4 TERMITE TREATMENT VERIFIED X 5 COMPACTION TESTING X 6 FORMING DIMENSIONS X 7 INSIDE OF FORMS CLEAN X 8 WIRE MESH REINFORCING SIZE AND LAP X 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING X 10 SPLICES X 11 REBAR CLEAN AND FREE OF OIL X 12 REBAR CLEARANCE FROM FORMS AND EARTH X 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED X 14 SHORING AND RE -SHORING X 15 POST TENSIONED CABLE LAYOUT AND PROFILE Disposition of Inspection X Section / Area Approved Re -Inspection Work In Progress RRe-Inspection Required COMMENTS/ACTION REQUIRED: VERIFIED DEPTH AND PREP FOR EPDXY DOWELS TRUSS # FG01 AT ROOM #124. .�NI{Illlf// APR 2 1 OECD Inspection Performed �: Inspection Certified B)C * . PA JL Registered Professional NC P(Fr e Certified Special Inspector No -Z& i A FBPE Certificate No: 4AD 4;�7201S H. DANF H, P.E. 14653 a STATh '-Jr :'.01 Environmental . Geotechnical . Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code Complianeelf/// 1111111 Florida's Leading Engineering Source ILE COFY F 1 Enfernrise Drive. Port St. Lucie. Florida 3498(i NUNN I s V v 2TFRNAT���P GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0068 OWNER WEATHER CONTRACTOR KAST TEMPERATURE ARCHITECT WIND ENGINEER HUMIDITY TYPE OF INSPECTION: ROOF TRUSS CONN MEMBERS/AREA INSPECTED: TRUSS TO MASONRY CONNECTIONS AT ROOM NO. 157 (PAVILION) 1/ TRUSS GIRDERS #F04G, # F08G A) DETAILS ARE NEEDED (UPLIFT >2300#) 2/ TRUSS NOS. EJ1 H, EH2H, EJ3H, EH4H, EJ5H, EJ6H, EJ7H A) DETAILS ARE NEEDED 3/ TRUSS # HJ3F A) 1-STRAP ONLY 4/ TRUSS NOS. EJ18G, EJ17G, EJ16G, EJ15G, EJ14G, EJ13G. A) STRAPS ARE MISLOCATED - REMEDIAL DETAILS ARE NEEDED. 5/ TRUSS# EJ12F (NORTH ELEVATION) A) NO STRAPS 6/ TRUSS # F01 Al 1 -12" STRAP 7/ TRUSS # F02 A)l-16" STRAP TRUSS TO TRUSS CONNECTIONS (NO EXCEPTION TAKEN) Disposition of Inspection Section / Area Approved Work In Progress COMMENTS/ACTIONREQUIRED: [ION D APR 2 7 REUD 0 Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Thursday, February 19, 2015 S I M I T I W 1TH F S DAY 19TH BRIGHTSUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0023A LOW MODERATE HIGH X RX Re -Inspection Re -Inspection Required ANP Inspection Performed Eta, HIS • L N •• TE' 25�� Inspection Certifiedoy: ;• N k44 4653•;a�z�� * aul H. Danfo Registered Professionallslo: E. 44653 �r Certified Special Inspector t1o"1103�.rAT QF :,�� FBPE Certificate N$: Oak ,cc, c�Q:•_�'��� . Construction Materials Testing • Special & Threshold Inspections . Plan Review & Co"yi . RM N A L %' Florida's Leading Engineering Source 11411 r 1 1 111,, M y FILE CORI 521 Enfer rise Drive, Port St Lucie, Florida 34986 GFA PROJECT # 12-1287.01 RNAT� PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE i ARCHITECT N/A WIND ENGINEER N/A HUMIDITY Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Sunday, March 29, 2015 S I M I T I W I TH F S DAY I X BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No 0023C LOW MODERATE HIGH TYPE OF INSPECTION: ROOF TRUSS SUMMARY MEMBERS/AREA INSPECTED: ITEMIZED TRUSS DEFICIENCIES ARE SHOWN BELOW. THE LOCATIONS ARE MARKED AND HIGHLIGHTED ON THE ATTACHED ROOF FRAMING PLAN. REMARKS; RESPONSE TO RFI # 1481-1 AND COPIES OF THE FIELD INSPECTION REPORTS ARE ATTACHED. 2/12/2015 1) FG05 AT SKY LIGHTS - T-BRACES MISSING, (4) LOCATIONS 2) FG04 AT NORTH END ROOM #142 - T-BRACES MISSING 3) FG04 AT SOUTH END ROOM # 140 - T-BRACES MISSING 2/13/2015 - ROOM #124 1) EJ1, EJ3, EJ4 - CLIPS/STRAPS NOT PER SCHEDULE 2) A09G - CLIPS/STRAPS NOT PER SCHEDULE 3) A010 - STRAP (1) SIDE ONLY 4) A01 (4) TRUSSES - STRAPS NOT PER SCHEDULE 5) A05 - T-BRACES NEEDS TO BE RENAILED 6) TRUSS GIRDER A08G - SEE RFI #1481-1 2/19/2015 - TRUSS TO MASONRY WALLS, ROOM # 157 (PAVILION) 1) TRUSS GIRDER FG04G, F08G - SEE RFI #1481-1 , 2) EJ1H, EJ2H, EJ3H, EJ4H, EJ5H, EJ6H, EJ7H - DETAILS NEEDED 3) HJ3F - (1) STRAP MISSING 4) EJ18G, EJ17G, EJ16G, EJ15G, EJ14G, EJ13G - STRAPS ARE MISALIGNED - 5) EJ12F (NORTH) - NO STRAPS 6) F01 - (1) 12" STRAP NOT PER SCHEDULE 7) F02 - (1) 16" STRAP NOT PER SCHEDULE Disposition of Inspection Section / Area Approved Work In Progress c�IEod[E APR 2 7 HELD D Rx Re -Inspection Re -Inspection Required Inspection Performed Inspection Certified Registered Professional Certified Special Inspector C * * PAIL H. FBPE Certificate No: %1 ij ANI •YJ3j _ STATE P.E. 01- . Construction Materials Testing . Special & Threshold Inspections . Plan Review & Code C.Atee v IV H V Florida's Leading Engineering Source flllllll►� 521 Enrerpril nve,E0t.LCueFQ0ra3 P86 v ��rFRNAT�o�P GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE 1916 PERFECT DRIVE, PORT ST. LOCATION LUCIE, FL PERMIT NO. 1404-0063 OWNER WEAT CONTRACTOR KAST TEMPERAT ARCHITECT W ENGINEER I HUMID I TYPE OF INSPECTION: ROOF AND EXTERIOR WALL SHEATHING REVIEW. HER URE IND ITY Phone: (772) 489-9989 Fax: (772) 489-2989 GENERAL INSPECTION REPORT DATE Thursday, April 09, 2015 S I M I T I W I TH F S DAY 9TH BRIGHTSUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0024 LOW MODERATE HIGH X MEMBERS/AREA INSPECTED: JOHN POSTHLETHWAITE, BN 2543, INSPECTOR AT GFA INTERNATIONAL, INC. HAS REVIEWED THE INSPECTION LOG AS REQUESTED. I * THE REPORT DATED 01/02/2015 IS THE FINAL INSPECTION OF THE ROOF SHEATHING. THE ROOF SHEATHING HAS PASSED. * THE WALL SHEATHING WAS INSPECTION ON 12/23/2014. THE WALL SHEATHING HAS PASSED. THESE REPORTS WERE SUBMITTED AT THE TIME ,OF THE INSPECTION. ADDITIONAL COPIES OF THE AFOREMENTION INSPECTION REPORTS ARE ATTACHED FOR YOUR CONVENIENCE. I I 1 Disposition of Inspection VSection / Area Approved ]Work In Progress COMMENTS/ACTION REQUIRED: D [E APR Z 7 REC'D Environmental • Geotec RRe -Inspection Re -Inspection Required Inspection Performed By: Inspection Certified By: Registered Professional Nor. Certified Special Inspector NO" FBPE Certificate No • Construction Materials Testing • Special & Threshold Inspections • Plan Review & C (Florida's Leading Engineering Source I 11111111/ .:44653 :103 8 TAT E O F pNRA� �tG•.•r\� � m'o"IL '�8'x. :� cory 521 Enterprise Drive, Port St. Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER i PGA OF AMERICA I WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIN13 ENGINEER N/A I HUMIDITY TYPE OF INSPECTION: TRUSS INSPECTION I MEMBERS/AREA INSPECTED: REVIEWED OUTSTANDING ITEMS AND RFI REMARKS; Disposition of Inspection RSection / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: D CC�G���/CG APR 2 7 AECD D RX Re -Inspection Re -Inspection Required Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Thursday, April 09, 2015 S M I T W I TH F S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH 0025 X Inspection Performed By: 44 Inspection Certified Registered Professionaeck Certified Special InspectoAo: r -Q FBPE Certificate%lo3 L..­- Environmental • Geotechnical e Construction Materials Testing • Special & Threshold Inspections -Plan Review i• Florida's Leading Engineering Source 91 # 2543 N6)AWW$Z, P.Er: �r ¢ 09.3o STATE OF rpii#nce✓ f'� �-_�A SOON A1.��� ��//11111111� FI Enferp GFA PROJECT# PROJECT LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER I, orf SI �RNAT�� 12-1287.01 PGA VILLAGE CLUBHOUSE ADDITION 1 1916 PERFECT DRIVE, PORT ST. LUCIE, FL 1404-0063 PGA OF AMERICA KAST N/A N/A WEATHER TEMPERATURE WINO HUMIDITY TYPE OF INSPECTION: TRUSS INSPECTION j MEMBERS/AREA INSPECTED: CONTINUED REINSPECTION OF ROOF TRUSSES REMARKS; I Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Thursday, April 09, 2015 S I M T I W TH F S DAY X I Disposition of Inspection Section / Area Approved NX Re -Inspection Work In Progress Re -Inspection Required COMMENTS/ACTION REQUIRED: BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0026 LOW MODERATE HIGH X �Illlllllf/fQ Inspection Performed TLE IT54 D 44653 �� Inspection Certified z : ; 4k APR 2 7 REC'D F.AUL H. D * TH, P.E. • - Registered Professional 39o. •E. #44653 Certified Special Inspector lb:lSTATE OF � FBPE Certificate Noe,' ••'•,`4 0��.•'• ��, Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code c IN A, 'Florida's Leading Engineering Source fff1111111 1 GFA PROJECT # 12-1287.01 1 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY TYPE OF INSPECTION: EXTERIOR DOOR / MEMBERS/AREA INSPECTED: INSPECTED F Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Friday, April 10, 2015 S I M I T I W I TH I F I S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH 0027 X W INSPECTION ING OF DOOR #141. 156, 157B REMARKS: REFERENCED DOCUMENTS: NOA # 12-0117.05 - TRULIGHT 350` NOA # 11-1117.02 - TRULIOGHT 3100 RESISTOR ALUMINUM STORE FRONT WINDOW WALL SYSTEM * RESISTOR SERIES MEDIUM STILE IMPACT OUTSWING CURTAIN WALL SYSTEM DOOR I Disposition of Inspection eX Section / Area Approved Re -Inspection Work In Progress HRe-Inspection Required COMMENTS/ACTION REQUIRED: �.- -•i Inspection Performed By: J �� 3 D Inspection Certified By: Q4ro3 �'ayzz 01 SPA TH, P.E. � �± APR 2 7 RECD Registered Professional No:P�:#44653 or Certified Special Inspector No==SfG'k3 U FBPE Certificate No: ��. A.••. .•• Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Cal & lO w' Florida's Leading Engineering Source lf�/��„'I,V"/1'���� I FILE COF-Y 521 Enterprise Drive, Port St. Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Friday, April 10, 2015 S M T W TH F S DAY X BRIGHTSUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0028 LOW MODERATE HIGH X Disposition of Inspection R Section / Area Approved Re -Inspection Work In Progress Rx Re -Inspection Required COMMENTS/ACTION REQUIRED: �/ ,, NF ,, DE � .IE D V E Inspection Performed BM% !i w # 2543 Inspection Certified Q : �' •••, S' /z015 APR 2 7 RECD , ;% LN.QDA , P.E. * = Registered ProfessionaiNt. E. 4$653 , • Certified Special Inspectog $I 1103 FBPE Certificate�o(��193o STATE OF w� Environmental . Geotechnical • Construction'Materials Testing • Special & Threshold Inspections . Plan Review ppW'�1i2„oe. • • • • • •!G_�``v Florida's Leading Engineering Source ����;; f0N A; ',,`0 FILE CO-PY •. . . GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE AC LOCATION 1916 PERFECT DRIVE, PORT ST. PERMIT NO. 1404-0063 OWNER PGA OF AMERICA CONTRACTOR KAST CONSTRUCTION ARCHITECT N/A ENGINEER N/A Phone: (772) 924-3575 Fax: (772) 924-3580 CONCRETE PLACEMENT INSPECTION REPORT DATE Thursday, February 12, 2015 ON S M T W TH F S IE, FL DAY 12TH WEATHER TEMPERATURE WIND HUMIDITY MEMBERS/AREA INSPECTED: SIGN FOOTING AND TIE BEAM AT ROOM # 157. BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0020 LOW MODERATE HIGH X THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO NIA X 1 SPARE VIBRATOR ON HAND X 2 FORMS WETTED/OILED X 3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW) X 4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW) X 5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAY'S POUR X 6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME X 7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET X 8 SUFFICIENT VIBRATION PERFORMED X 9 STEEL REMAINED IN PLACE DURING POUR X 10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS AREA POURED YDS PSI TYPE MIX SLUMP IN ± IN START TIME END TIME METHOD OF PLACEMENT SUPPLIER TIE BEAM & SIGN FOOTING 5 3,000 #8PM 14:45 15:30 PUMP TITAN Disposition of Inspection MSection / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: DL=-U APR 2 7 REC'D Re -Inspection Re -Inspection Required Inspection Performed B911.1v Jop Inspection Certified B2 Registered Professional N PAJ - P Certified Special Inspector No!,-5l FBPE Certificate No: ro. j111111811, ANFO -�i� G N S •'•• ��i do 412 o E NFO E. Environmental • Geotechnical • Construction'Materials Testing • Special & Threshold Inspections • Plan Review & Code ComplrIZA/11111111j1% Florida's Leading Engineering Source I FILE CC--?Y � 521 NW Enterprise Drive, Port St. Lucie, Florida 34986 GFA PROJECT# 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST.1 LUCIE, FL PERMIT NO. OWNER 1404-0063 PGA OF AMERICA CONTRACTOR KAST CONSTRU ARCHITECT N/A WEATHER TEMPERATURE WIND ENGINEER N/A HUMIDITY MEMBERS/AREA INSPECTED: =Re -Inspection 1) HSS 6" X 2" X 1/4, DWG 12/CW4 AT ROOM #124; NORTH (INTERIOR) WALL a) CONNECTIONS TO LIGGHT GAUGE METAL WALL BELOW IS COVERED 2) W8K20, DWG 13/CW-5 AT ROOM #124, INTERIOR WALL a) BEAM CONNECTIONS ARE COVERED b) DETAIL 5/S2.2 SHOWS HSS BEAM. II THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED i CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. CAPR nCOMPLIES �VJYES NO N/AX 1 MILL CERTIFICATION AND TEST REPORTS X 2 DISTORTION, EXCESSIVE] RUST, BURNED HOLES RECD X 3 CAMBER X 4 SIZE, THICKNESS, WEIGHT X 5 SPLICES X 6 BOLTS IN ALL BOLT HOLES X 7 ANCHOR BOLT SIZE, LENGTH, PLUMBNESS, EMBEDMENT, THREAD PROJECTION X 8 HIGH TENSILE BOLT SIZE', LENGTH, TYPE, WASHERS, NUTS X 9 BOLT TORQUEING X 10 COLUMN ALIGNMENT, BASE PLATE SIZE AND FIT X 11 GROUTING OF BASE PLATES X 12 BAR -JOIST SIZE, SPACING, BEARING, CONDITION X 13 BAR -JOIST BRIDGING AND BRACING X 14 CORRUGATED ROOF DECK GAUGE, CONDITION, SIDE AND END LAPS X 15 HEADED STUDS PLACEMENT AND WELDING DISPOSITION OF INSPECTION: =Section / Area Approved =Work In Progress EIRe-Inspection Required c. Phone: (772) 924-3575 Fax. (772) 924-36 STRUCTURAL STEEL INSPECTION REPORT DATE Friday, April 10, 2015 S M T W TH F S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH X Report No LOW MODERATE HIGH X 0029 COMMENTS / ACTION REQUIRED: MEMBERS AND CONNECTIONS ARE COVERED, BOTH SI Inspection Performed By: ,� /'OS T I , Bl%hu On Site I Inspection Certified By:: * adz/zo7s § -PAll; H. DANFORTH, P.E. Off Site P , Registered Professional No: ;.� 465 �: � e Travel Certified Special Inspector No: Sr7 ••tic(„ P.' ���` form revised 11/21/06 Total Hours =>g' FBPE Certificate No: 4930��i S/ AI A I •F� k Environmental a Geotechnical a Construction Materials Testing a Special & Threshold Inspections a Plan Review & Code Compliance Florida's Leading Engineering Source FILE COFY 521 Enterprise Drive, Port St Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A i HUMIDITY TYPE OF INSPECTION: LIGHT GAUGE METAL FRAMING MEMBERS/AREA INSPECTED: LIGHT GAUGE STUD FRAMING, ROOM #124 REMARKS; a) WALL IS COVERED BOTH SIDES, CANNOT INSPECT b) REQUIRED SHOP DRAWING SUBMITTAL NOT AVAILABLE FOR INSPECTION I I Disposition of Inspection Section / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: APR 2 7 OECD D Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Friday, April 10, 2015 S M T W TH IF DAY X Rx Re -Inspection Re -Inspection Required BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0030 LOW MODERATE HIGH X Inspection Performed By: JI Inspection Certified By: R Registered Professional No: I: Certified Special Inspector No: FBPE Certificate No: Environmental • Geotechnical e Construction;Maledals Testing . Special & Threshold Inspections . Plan Review & Florida's Leading Engineering Source t44653'A0 44653 •� T• STATF arm O R 1 �. •G\,�� �i��i'�p1V FILE COF'7 i 521 Enterprise Drive. Port St Lucie. Florida 34986 GFA PROJECT# PROJECT LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER 12-1287.01 PGA VILLAGE CLUBHOUSE ADDITION 1916 PERFECT DRIVE. PORT ST. LUCIE. FL PGA OF AMERICA WEATHER KAST CONSTRUCTION TEMPERATURE N/A WIND N/A HUMIDITY TYPE OF INSPECTION: ROOF TRUSS MEMBERS/AREA INSPECTED: ROOM #157 REMARKS:1) TYPICAL a) HSTM20 STRAPS, (4) TAPCONS IN CONCRETE, SPECED 1" O.C. b) HSTM 20 STRAPS ARE NOT APPROVED c) BRACING IS INCOMPLETE Disposition of Inspection Section / Area Approved Re -Inspection Work In Progress Rx Re -Inspection Required COMMENTS/ACTION REQUIRED: Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Monday, April 13, 2015 S I M I T W I TH I F I S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0031 LOW MODERATE HIGH X 22 _�%f_( �_ _ I I I I IIIOI D-- L � � [a U �:/ L� Inspection Performed By: J • . .I �, 43 Inspection Certified By: �•�'A t/� s APR 2 7 REUD H. D . Registered Professional Nd: P. :#44653 Certified Special Inspector NCEW 0 • p- 3iAiE OF lV FBPE Certificate No:lzw.. Environmental • Geotechnical • ConstructionMaterials Testing . Special & Threshold Inspections • Plan Review & Code dg, j • • • • • • • •' •w` �� Florida's Leading Engineering Source �I��,ONA; 11%`,���,, I �'ILE COFY 521 Entervrise Drive. Port St. Lucie. Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA CONTRACTOR KAST CONSTRUCTION ARCHITECT N/A ENGINEER N/A TYPE OF INSPECTION: ROOF TRUSS MEMBERS/AREA INSPECTED: ROOM #157 WEATHER TEMPERATURE WIND HUMIDITY Phone: (772) 924-3575 Fax: (77? 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 14, 2015 S I M I T I W I TH F S DAY X REMARKS; 1) TRUSS F04G TO CONCRETE WALL a) UPLIFT OF 3735 AND 3736 SHOWN ON TRUSS DWG. ENGINEER TO ADVISE 2) TRUSS EJ4H TO F08G a) THAR 29 b) NAILS MISSING 3) EJ6H TO F04G - TOE NAILING SHOWN THAR 29 USED 4) EJ5H TO F04G, THAR 429 SHOWN THAR 29 USED. NAILS MISSING 5) HJ3F TO F08G a) OK I GENERAL NOTES: 1) TRUSS DWG SHOWS THAR 29 a) NOT LISTED IN TRUSS HANGER SCHEDULE 2) HJ3F TO F08G, TRUSS DWG SHOWS THAR 429, NOT ON SCHEDULE Disposition of Inspection i Section / Area Approved Re -Inspection Work In Progress Rx Re -Inspection Required COMMENTS/ACTION REQUIRED: BRIGHTSUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0032 LOW MODERATE HIGH X 1111 11111 , DA � �/�(���__ Inspection Performed By: cb� t} IDf 2543.IE Inspection Certified B�♦ F••. � ms LL H. E.•: 0 Registered Professional Flo: I?E. 4653 APR 2 7 RECD Certified Special Inspector 11;�O 1103 FBPE Certificate hPo •3p TgTE OF ' Environmental _G qotechnical • Construction Materials Testing • Special & Threshold Inspections . Plan Review & 00%. • ....G• Florida's Leading Engineering Source ��I /ON AL lillllll,, R. ■ 521 Enterprise Drive, Port St. �� y Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE. FL PERMIT NO. 1404-0063 OWNER PGA OF AMER] CONTRACTOR KAST CONSTRUC ARCHITECT N/A ENGINEER N/A TYPE OF INSPECTION: ROOF TRUSS MEMBERS/AREA INSPECTED: ROOM #127 AND REMARKS; ROOM #127 1) GIRDER F09G TO CONCRETE a) OK PER RFI #1481-1, ITEM #1 2) GIRDER F04G a) UPLIFT > 2300 LBS - FOR TO ADVISE BRACING INSPECTION ROOM #124 #124 WEATHER TEMPERATURE WIND HUMIDITY Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 14, 2015 S M T W TH F S DAY X BRIGHTSUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH 0033 X 1) TRUSS FG01 a) DOUBLE TRUSS, NO GANG NAILING AT TOP CHORD, BOTTOM CHORD AND WEBS 2) A08G AT FG01 a) STRAPS PER RFI #14-1481-1, ITEM #4 - OK 3) TRUSS A09G TO INTERIOR WALL Disposition of Inspection Section / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: DIg,�-VL=U W Lc. - APR 2 7 RECD Rx Re -Inspection Re -Inspection Required Inspection Performed By: Inspection Certified By k •H Registered Professional N(i P41 Certified Special Inspector Noa,0103 FBPE Certificate No: $93t IITFI, P.E. • r Environmental . Geotechnical • Constructionl`Materials Testing . Special & Threshold Inspections . Plan Review & Code C�I' c�O I� 1 ^ `� iFlorida's Leading Engineering Source � III I100% I _� � LE CC-4.)Y 521 Enterprise Drive, Port St. Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA CONTRACTOR KAST CONSTRUCTION ARCHITECT N/A I ENGINEER N/A I WEATHER TEMPERATURE WIND HUMIDITY TYPE OF INSPECTION: MEMBERS/AREA INSPECTED: 1) RFI #55, ROOM #152A -142 a) 2K4 STUD FRAMING IS NOT COMPLETED BLOWI2-21<12 LEDGER b) 2K6 BLOCKING BETWEEN TRUSSED, NOT IN PLACE Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Wednesday, April 15, 2015 S M T W TH F S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0034 LOW MODERATE HIGH X c) SECTION 10/S2.2 SHOWS TRUSSES CONNECTED TO CONCRETE WALL. TRUSSES ARE CONNECTED TO THE LEDGER * 2) RFI #73 a) INSPECTED FRAMING PER RFI #73, APPROVED COPY RFI IS PENDING 3) LIGHT GAUGE METAL FRAMING a) INSPECTED FRAMING PER STRUCTURAL DRAWINGS, SHOP DRAWINGS ARE PENDING ** 4) EXTERIOR WINDOW ATTACHMENT a) COMPLETED 5) EXTERIOR DOORS a) EXTERIOR DOORS NOT INSTALLED 15015, 14713,1131A, 1316, 126A ** b) STORE FRONT DOOR COMPLETED 6) SCREEN WALL a) 1-THRU BOLT MISSING ** I Disposition of Inspection X Section / Area Approved ** Re -Inspection Work In Progress Re -Inspection Required COMMENTSIACTION REQUIRED: DA APR 2 7 HELD Inspection Performed By: m Inspection Certified By:Z Registered Professional No: Certified Special Inspector No: FBPE Certificate No: WAR 4/z2/2ti._ ANFO H, P.E. HAARF3 _ _ — — • . Environmental . Geotechnical . Materials Testing • Special & Threshold Inspections . Plan Review & Code Compliance' 111 Florida's Leading Engineering Source FILE COP 521 Enterprise Drive, Port St Lucie, Florida 34986 GFA PROJECT# PROJECT PGA VILLAGE LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER 12-1287.01 ! 1916 PERFECT DRIVE TYPE OF INSPECTION: MEMBERS/AREA INSPECTED: 7) TRUSS ENGINEERING a) COMPLETED 1404-0063 Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Wednesday, April 15, 2015 ADDITION S I M I T W TH F S ST. LUCIE, FL DAY X PGA OF AMERICA WEATHER i KAST CONSTRUCTION TEMPERATURE I N/A WIND N/A HUMIDITY 8) TRUSS CONNECTIONS a) F04G AT ROOM #154 AND 125 UPLIFT > 2300 LBS - FOR TO COMMENT L % Cnnfl AT rW%r%hA 40A / IIITrIJCAI In1rnnAol CTC * BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0035 LOW MODERATE HIGH X c) TRUSS STRAPS HSTM20 USED IN LOCATIONS WHERE EMBEDDED STRAPS ARE MISALIGNED 9) STRUCTURAL STEEL a) 3-GIRDERS WITH HSS BEAM RUNNING PARALLEL, CLIPS FOR TRUSS ATTACHMENT APPROVED BY FOR (EMAIL DATED 4/14/15, ITEM #1) 10) BRACE DETAILS, 12/S2.3, G/2.4 ** a) BOLTS AND ANCHORS ARE HOT DIP GALVANIZED, DRAWING NOTES SHOW STAINLESS STEEL b) TOE NAILING, TRUSS TO BEAM, NOT COMPLETED c) L 6X4X5/16" (12/S2.3), NOT COMPLETED d) WEDGE ANCHORS USED IN LIEU OF EPOKIED ANCHORS Disposition of Inspection Section / Area Approved PIRe-Inspection Re-Inspection eWork In Progress Required COMMENTS/ACTION REQUIRED: U� APR 2 7 HECp Inspection Performed By: JGfj,1 GPSTL T TE, N #.2gd3-.. Inspection Certified By: v * . 53 41221 &UL ti. kFORT*, P.E. Registered Professional No: P;E-.914653 ' 0- STATE OF k/e Certified Special Inspector No: Sri ,•._• Z FBPE Certificate No: 493V,' R 1 �.•'�-„� ��� Environmental • Geotechnical Materials Testing e Special & Threshold Inspections . Plan Review & Code Compliancgl f j j Florida's Leading Engineering Source 2r��' IE CO�I�Y 521 Enterprise Drive, Port St. Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION I TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY TYPE OF INSPECTION: TRUSS BRACING MEMBERS/AREA INSPECTED: 1) REINSPECTED TRUSS BRACING a1 REPAIRS HAVE BEEN COMPLETED ' Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Thursday, April 16, 2015 S I M I T I W I TH I F I S DAY X BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X LOW MODERATE HIGH 0036 X i I Disposition of Inspection. PSection / Area Approved X Re -Inspection Work In Progress Re -Inspection Required COMMENTS/ACTION REQUIRED: Ld D Inspection Performed By OH O BIf•# 25 ".*.p Inspection Certified Bye * 4/l /20hF [E:(dD �PAI� H. DA P.E. �+ Registered Professional NorP . 5 f • Certified Special Inspector No: %�3. k , FBPECertificate No: 49 s••''••C-•''••• ��♦ Environmental 9 Geotechnical e Construction Materials Testing . Special & Threshold Inspections • Plan Review & Code Compliance-1111111 Florida's Leading Engineering Source .. b FILE 5211 Drive, Port St ! GFA PROJECT# PROJECT LOCATION PERMIT NO. OWNER CONTRACTOR ARCHITECT ENGINEER Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT 12-1287.01 DATE Tuesday, April 21, 2015 PGA VILLAGE CLUBHOUSE ADDITION S M T W TH F S 1916 PERFECT DRIVE, PORTI ST. LUCIE, FL DAY 21ST 1404-0063 1 WEATHEP TEMPERATURE WINC HUMIDITY PGA OF AMERICA I KAST CONSTRUCTION N/A N/A TYPE OF INSPECTION: REINSPECTIONS BRIGHTSUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No LOW MODERATE j ",IGH0037 MEMBERS/AREA INSPECTED: 1/ TRUSS ATTACHMENT TO STEEL GIRDER (ITEM NO. 1) THAT ARE ATTACHED TO CLIPS PLACED PARALLEL TO TRUSSES APPROVED BY ENGINEER OF RECORD - SEE EMAIL FROM MATT LOWE, P.E. DATED 04/14/2015 - PASS. 2/ ITEM NO. 3, EMAIL DATED 04/14/2015 I A) THE HGAMIOKTA CONNECTORS HAVE BEEN ADDED PER ENGINEER OF RECORD RESPONSE - PASS. 3/ ITEM NO. 4, EMAIL DATED 04/14/2015 A) FOOTING FASTENED PER SIMPSON TABLES - PASS. 4/ TRUSS CONNECTION, A09G AT ROOM # 124, RFI I# 1481-1, ITEM NO. 2. A) SIMPSON VGT CONNECTOR INSTALLED - PASS. B) SEE ENGINEER OF RECORD COMMENTS REGARDING ADDITIONAL STUD FRAMING REQUIRED. SHOP DRAWINGS ARE PENDING. SEE EMAIL DATED 04/15/2015 FROM ENGINEER OF RECORD, ITEM NO.2 - INCOMPLETE. Disposition of Inspection NSection / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: eRe-inspection Re -Inspection Required ITEMS 1, 2,3 AND 4.A - PASS. `ITEM # 4.B IS PENDING. ��♦����� n ♦ '; A APR 2 7 !10 No 465 Inspection Perfo&db y: JOHN OS THWAjT W # 2543 Inspectio y: 41241201. WAIf eAIjIF.ORTH� F .- 6 tu! FF � �� Registered Professiag��l'o� 44653 • Certified Special Inspect&®�+f•1.3R p••;��� ��� FBPE Certificate No!t NALE7j%%S • Construction Materials Testing • Special & Threshold Inspections e Plan Review & Code Compliance Florida's Leading Engineering Source 521 Enterprise Drive, Port St Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORIj ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY TYPE OF INSPECTION: REINSPECTION --SKYLIGHT CURBS MEMBERS/AREA INSPECTED: 5/ REINSPECT SKYLIGHT CURBS. ADDITION STRAPS WERE ADDED PER DRAWING. Disposition of Inspection Section / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 21, 2015 S M T W TH F S DAY 21 ST BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No 0037A LOW MODERATE HIGH I 11KIRe-inspection Re -Inspection Required %H t DAN/` LE J `r t Inspection Performed Bg Jq N POSTLE H ITE, BN D Inspection Certified Bye _1 APR 2 7 REUD Registered Professional No. PV*RP:•••.•:• p. Certified Special Inspector No: SI FBPE Certificate No: 4930 ���111111111,, Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance Florida's Leading Engineering Source 521 Enterprise Drive, Port St. Lucie, Florida 34986 �HNAT1�' GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR I(AST CONSTRUCTION TEMPERATURE ARCHITECT N/A WINE ENGINEER N/A HUMIDITY TYPE OF INSPECTION: REINSPECTIONS Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 21, 2015 S M T W TH F S DAY 21 ST BRIGHTSUN CLEAR OVERCAST RAIN X X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0037E LOW MODERATE HIGH X MEMBERS/AREA INSPECTED: RECEIVED APPROVED DETAIL, DATED 04/20/2015 REGARDING MASONRY TIE-IN AT ROOM # 124/125. 1 RECEIVED APPROVED DETAIL FOR THE WALL FRAMING AT VESTIBULES. I R; ; wran ; ' ; t. ig t v Disposition of Inspection Section / Area Approved Re -Inspection eWork In Progress HRe-Inspection Required COMMENTS/ACTION REQUIRED: _ 4�0/NPOST •, y Inspection Performed BE a$, 13 P-* 250 Inspection Certified EW:�J2#2S EORTH, P.E.APR 2 7 RECD Registered Professional N6T� OF Certified Special Inspector No: �Vidb;T C-O R I p P'.•������, ... '"� FBPE Certificate No: 493� �,,_ NA L EnvironmeMaT•-Geotechnical yconstruction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance IFlorida's Leading Engineering Source