HomeMy WebLinkAboutGeneral Inspection Report 5-20521 St Lucie, Florida GFA PROJECT# 12-1287.01 PROJECT PGA VILLAGE CLUBHOL LOCATION 1916 PERFECT DRIVE Pn; PERMIT NO. 1404-1 OWNER PGA OF A CONTRACTOR KAST CONS' ARCHITECT N// ENGINEER N9 TYPE OF INSPECTION: REVIEW MEMBERS/AREA INSPECTED: 1) SLAB - COMPLETE 2) STEM WALLS - COMPLETE 3) FOOTINGS AND BASE FOUNDATION WITH EXTERIOR FRAME AND C.M.0 WALLS - C% i) TIE BEAMS AND VERTICAL COLUMNS - CON i) IDENTIFY THAT ALL EXPANSION SLAB CUT! STEEL FRAME SYSTEM WITH BOLTING ANC Disposition of Inspection Section / Area Approved Work In Progress COMMENTS/ACTION REQUIRED: ALL STEEL - - CO (772) 924-3575 Fax. (7721924-3580 I GENERAL INSPECTION REPORT DATE Wednesday, April 29 2015 S M T W TH F S FL DAY 2ATH WEATHES TEMPERATURE WIND HUMIDITY BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVEGO LOW MODERATE HIGH Report No 0039 LOW MODERATE HIGH PER PLANS - Required LE 0 V D F. -- - ' • Inspection Performed �: N P L 44 A Inspection Certified:: MAY 2 0 REC'D A Registered Professional N4 !L 4 eI� Certified Special Inspector No., •••. O R . FBPE Certificate No; 493�4� SON p►� Environmental • Geotedw%cal • Construction Matedals Testng • pecial & Threshold Inspoctions • Man Review & Code Compliance Florida's Leading ugineerin9 Source F2M 521 Enterprise Drive. Port St Lucie. Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY TYPE OF INSPECTION: REINSPECTIONS MEMBERS/AREA INSPECTED: Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 21, 2015 S M T W TH F S DAY 21 ST BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report No 0037 LOW MODERATE HIGH APPROVED BY ENGINEER OF RECORD - SEE EMAIL FROM MATT LOWE, P.E. DATED 04/14/2015 - PASS. 2/ ITEM NO. 3, EMAIL DATED 04/14/2015 A) THE HGAMIOKTA CONNECTORS HAVE BEEN ADDED PER ENGINEER OF RECORD RESPONSE - PASS. 3/ ITEM NO. 4, EMAIL DATED 04/14/2015 A) FOOTING FASTENED PER SIMPSON TABLES- PASS. 4/ TRUSS CONNECTION, A09G AT ROOM # 124, RFI # 1481-1, ITEM NO.2 A) SIMPSON VGT CONNECTOR INSTALLED - PASS j B) SEE ENGINEER OF RECORD COMMENTS REGARDING ADDITIONAL STUD FRAMING REQUIRED. SHOP DRAWINGS ARF PFNinimc,_ SFF FMAII nATFn n411S19015 FRnM FN(-.INFFR nF RFCnRn ITFM Nn 9 - INCnMPI FTF MEOW E A-M1ME 0 ff� i Disposition of Inspection qWork Section / Area Approved X Re -Inspection In Progress * Re -Inspection Required `,%1111111, COMMENTS/ACTION REQUIRED: (1) ITEMS 1, 2.3 AND 4.A - PASS. *ITEM # 4.B IS PENDING. A% -%X, ` ;°D - Inspection Performed fir: J HN P E* ITE, BN� 25 DInspection Certified �. ;: t �i� �T�IAPANFORTH,P. . _f% MAY 2 D RECD Registered Professional No�.s�® >t �_.�,;.���� Certified Special Inspector No: Sill �Qees o � fffllq�� FBPE Certificate No: 4930 I —�� Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance Florida's Leading Engineering Source 521 i Port St Lucie. Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY TYPE OF INSPECTION: REINSPECTIONS - SKYLIGHT CURBS MEMBERS/AREA INSPECTED: 5/ REINSPECT SKYLIGHT CURBS. ADDITIONAL S Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 21, 2015 S M T W TH F S DAY 21 ST i Disposition of Inspection X Section / Area Approved MIRe-Inspection Re -Inspection Work In Progress Required COMMENTS/ACTION REQUIRED: BRIGHT SUN CLEAR OVERCAST RAIN BELOW 60 60-75 75-90 ABOVE 90 LOW MODERATE HIGH Report Na 0037A LOW MODERATE HIGH WERE ADDED PER DRAWING. 0100E s••.9 h Inspection Performed By: N FbST WAITE,�V'# 4'.y Inspection Certified By U53 s/to/zolZ M AY 2 0 RECD ;7TL�P� NF , P.E. - Registered Professional No:?7:;$446 I D ��-: OF �z Certified. Special Inspector No: 1 3r-'�, _ FBPE Certificate No: 49%�rs'"'�:� 10.•.•' ��� #.. IAA .% Environmental • Geotechnical • ConsWction Materials Testing • Special & Threshold Inspections • Plan Review & Code Complian L11 J' 1 11.1f1��� Florida's Leading Engineering Source 521 Enterprise Drive, Port St, Lucie, Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORT ST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY Phone: (772) 924-3575 Fax. (772) 924-3580 GENERAL INSPECTION REPORT DATE Tuesday, April 21', 2015 S M T W TH IF DAY 21ST BRIGHT SUN CLEAR OVERCAST RAIN X X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 01137E LOW MODERATE HIGH X TYPE OF INSPECTION: REINSPECTIONS MEMBERS/AREA INSPECTED: RECEIVED APPROVED DETAIL, DATED 04/20/2015 REGARDING MASONRY TIE-IN AT ROOM # 124/125. RECEIVED APPROVED DETAIL FOR THE WALL FRAMING AT VESTIBULES. Disposition of Inspection FRX Section / Area Approved Re -Inspection ork In Progress RRe-Inspection Required COMMENTS/ACTION REQUIRED: \0�,�,"H"Q Q .• �_ICEn. •. n �i_ DI E IE 0 v E Inspection Performed E�: • N POS LET 4AITR, BN it Inspection Certified : MAY 2 0 RECD Registered Professional Nor �' E•`' rrartifinrlRnnrinl Incnartnrtdn• 5t,1�4A(;�••••I D•'•..•\\ �1 Environmental • Geotechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance Florida's Leading Engineering Source 521 Enterprise Drive. Port St. Lucie. Florida 34986 GFA PROJECT # 12-1287.01 PROJECT PGA VILLAGE CLUBHOUSE ADDITION LOCATION 1916 PERFECT DRIVE, PORTIST. LUCIE, FL PERMIT NO. 1404-0063 OWNER PGA OF AMERICA WEATHER CONTRACTOR KAST CONSTRUCTION TEMPERATURE ARCHITECT N/A WIND ENGINEER N/A HUMIDITY Phone: (772) 924-3575 Fax: (772) 924-3580 GENERAL INSPECTION REPORT DATE Friday, May 01, 2015 S I M I T I W I TH F S DAY 1ST BRIGHT SUN CLEAR OVERCAST RAIN X BELOW 60 60-75 75-90 ABOVE 90 X LOW MODERATE HIGH Report No X 0040 LOW MODERATE HIGH X TYPE OF INSPECTION: LIGHT GAUGE METAL FRAMING (REINSPECTION) MEMBERS/AREA INSPECTED: ROOMS 127, 124, 1I30, 133, 129, DOUBLE FASTENERS AT BOTTOM PLATE TO STUD CONNECTION ADD PER ENGINEER DRAWING ON -SITE WORK IS COMPLETE. ENGINEERS DETAIL FOR 4X4 POST IN ROOM 124 AND 127 SHOW ADDING 2-5/8 WEDGE ANCHORS AT BOTTOM PLATE CONNECTION. WORK IS COMPLETE PER PLAN. Disposition of Inspection X Section / Area Approved Re -Inspection Work In Progress PRe-Inspection Required COMMENTS/ACTION REQUIRED: THIS IS A REINSPECTION FROM THE 04/21/2015 INSPECTION, ITEM #4-B, RAISED SEAL DRAWINGS ON SITE, WORK IS PER DRAWINGS. THIS COMPLETES THE LIGHT GAUGE METAL FRAMING INSPECTIONS. ALL LIGHT GAUGE FRAMIN to MfiETD AND PAS; Inspection Performed By: D Inspection Certified B "� * : • S �•.'� ij is PAOL H. DAWOIR",q.: S AEC9D Registered Professional I9: 44653 2 MAY 0 c Certified Special Inspector 1601:110�s L FBPE Certificate N�mOT • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Codloo(�/y{c�l • :. • Florida's Leading Engineering Source " ►/q � ,� Q10i