HomeMy WebLinkAboutQualification Test Record ( Welder & Welding Operator.,
•
RIVER `
COMMUNITY°
COMMUNITY COLLEGE
WELDER AND WELDING, OPERATOR QUALIFICATION TEST RECORD
Welder or welding operator's name .......` PMMYY, . Creel, , , , , , , , , .. Identification No ... 900 50,391. , , .... ,
Welding Process ... S.MAW........ manual ;......X....... Semiautomatic ............... Machine.M?-ller....
I
Position.....6.G. A5.:. Fi_.xed...........................................................................
(Flat, horizontal, overhead or vertical -- if vertical state whether upward or downward)
In accordance with Procedure Specification No. A.W.$ ..Q1.. 1, , ,. . . . . ................... .
Material specification ...A36.. Tubular................................................................... .
Diameter and wall thickness (if pipe) otherwise joint thickness ... 2 ".. 5.c11.. A0..............................
Thickness range this qualifies ... $qh.,,1 0-.60
FILLER METAL
Specification No. .. AWS . A5..1.........1... Classification E, ,6 01 0, ... ,E70,18 , , , F No..3.. & 4
Describe filler metal (if not covered by AWS specification)
......................................................
I
Is backing strip used? ... NQ . . . . . . . . .. ... . . . . .... .. . ...
Filler metal diameter and trade name 118 . ,Z, Rg0.1Il , Flux for submerged arc or gas for gas metal arc or flux
..................................................... cored arc welding....................................
Guided Bend Test Results
F
Type_
Result
Type
Result
_
Tensile _
Accepted 73,500
PSI
___...—Tensile
Accepted
77 000
PSI
Test conducted by ..Gary...L... WO,m)J (* , , . , . , , , , Laboratory Test No. .......... '.................... .
per ....AWS , D1 _.1.... .......... .
RADIOGRAPHIC TEST RESULTS
Film
Identifi-
cation
Results
i
Remarks
Film
Identifi-
cation
Results
Remarks
�C .............
Test witnessed b .. Test no . ........................................
per.............. ....................
We the undersigned, certify that the sta ements in this record are correct and that the welds were prepared and
tested in accordance with the requir fD9 of 5C or D of AWS DI A, Structurial Welding Code.
[E'[E�
D
JUL -2 4 REM
�e Manufacturer or C tr ctor .... IRCCl/�,,,l�JJ,/I/./%
'V .
Authorized by . . .
.
-�6 - 9
Date....... / ......
L
fi- . � "'COPY
copy--Cumulative folder; Pink copy --Teacher. I
ATEC AssociaT8s,1
*V 9955 , 116 Way, Suite 1
Miami, Floror ida 33178-5126
(305) 882-8200, FAX (305) 882-1200
DCDCnDAA A KlPr
Client: CUSTOM WELDING
198�3 Biltmore Street
Port St. Lucie, Florida 34984
A. W. S. Certified
Test Facility
No. AWSQC-940808
Date Tested: 1 \20\95
Proj. #: 7002-95-001
Lab. #: W95-037
Name: Tommy Creel S/S #: 261-53-0838 I.D. #: _
Welder: X Operator: _ Eye Correction: None Type:
VARIABLES
AWS WPS No.: 1-QC-W2 Supplement No.: 1 Test No.: D1-SM-F4-P-A-L
Process(es): S.M.A.W. Manual: X Semi -Automatic: _ Automatic: _ Machine: _
Position: 3-G - Vertical Progression: Up I Single or Multiple pass: Multiple
Test Base Metal Specification: ASTM A-36 to ASTM A36 Material No.: P_1 to -
Filler Metal Spec.: AWS A5.1 Filler Metal Class.: E7018 F No.: 4 Size: 118"
Shielding Gas: N/A Flow Rate: N/A Backing: 1 /4" plate Current: AC: _ DC: X
Visual Test Results:
Bend Test Results:
Radiographic Test Results:
Pass: X Fall: _
Pass: X Fail: _
Pass: _ Fail:
Test Witnessed by: David Ortigoza, A.W.S. C.W.I. # 80115661 Radiographer: N/A
Process(es) Qualified For: S.M.A.W. Thickness Qualified For: 1 /8" to 3/4" Pipe Dia.: > 24"
POSITIO'N(s) QUALIFIED FOR:
Groove Fillet
Plate: 1-G X 2-G X 3-G X 4-G _ 1-F X 2-F X 3-F X 4-F _
Pipe: 1-G X* 2-G X* 5-G _ 6-G _ 1-F X* 2-F X* 4-F _ 5-F _
Only qualified for tubulars over 24 in. in diameter with backing or back gouging.
CERTIFICATION
This certifies that the statements in this record are correct and that the test coupons were prepared, welded
and tested in accordance with the requirements of Section 5, Part C of ANSI/AWS D1.1, 1994 Structural
Welding Code - Steel.
Review*by,
FILE
COPY
eter P.E. Manager, Traditional Services
FI. Reg. 3504
VAE d—
American Testing gineering Corporation
Offices in Major U.S. Cities/Since 1958
Respectfully Submitted,
AT SSOCIAT , INC.
2
David Ortigoza : `Y
Manager, NDE Department
Consulting Environmental, Geotechnical and
Materials Engineers