HomeMy WebLinkAboutLetter Review Comments For PermitJoe Cido
From: Joe Cicio
Sent: Friday, April 25, 2014 10:05 AM
To: 'LEOLHCI@GMAIL.COM'
Cc: Joe Cicio
Subject: Review Comments for Permit Number 1404-0063
Attachments: Report_FL_Review_Comments_Noncompliantjrf[1].pdf
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional , contractor or owner we
will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank you,
Jasepk. M. iudc'
Plans Examiner II
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwelling Inspector
One and,Two FarnilyPlans Examiner
St. Lucie County Planning and Development Services
772-462--1553
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Planning &Development Sentices
Building A Code Regulation Division
2300 Virginia Avenue.
Fort Pierce;.FL. 34982
Phone:(772)462 2172 'Fax:(7772j462.6443
PROPERTY INFORMATION
Address: 1916 Perfect Dr -Clubhouse
City / State / Zip: Port St Lucie, FI 34986
Parcel #: 3327-200-0001-000/4
Zoning: PNRD
APPLICATION INFORMATION
Permit Number: 1404-0063
Permit Type: BUILDING COMMERCIAL
CONTRACTOR INFORMATION
Contractor Name:
Leopoldo Henriquez
'Business Name:
Lh Construction Inc
Business Addr:
110 South 2Nd St
City / State / Zip:
Fort Pierce, FI 34950
REVIEWS AND COMMENTS
REVIEW COMMENTS
1
Owner(s):
Pga Reserve Inc
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 66 Block:
Stories: Automatic Sprinkler System? No
Fax Number: 772-429-0199
Email: LeolhcigGmail.Com
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Audrey Humphrey 4/3/2014
4/3/2014 Comment:
NEEDS TO SUBMITTED AN APPLICATION TO VEGETATION
4/3/2014 Comment:
NEEDS ALL SUBS FOR ELECTRICAL, PLUMBING, MECH AND ROOFING AND A SUB SUMMARY.
4/3/2014 Comment:
NOTICE OF COMMENCEMENT
ENVIRONMENTAL REVIEW
PENDING
Comment:
FIRE DEPARTMENT REVIEW
PENDING Tony Liento
Comment:
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 4/3/2014 4l3/2014 4/3/2014
Comment:
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 4/15/2014 4/1612014 4/16/2014
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 4/23/2014
Comment:
PLEASE FURNISH A REFLECTIVE CEILING PLAN SHOWING THE SUPPLY AND RETURN GRILLS SIZE AND
4/23/2014
LOCATION
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 4/15/2014
4/15/2014 Comment:
PLEASE ADD TO PLANS THE OCCUPANT COUNT BEFORE THIS REVIEW CAN STARTED
4/15/2014 Comment:
PLEASE SHOW LOCATIONS OF DRINKING FOUNTAINS PER TABLE403.1 FBCP 2010
7
w '
Planning & Development.Services
Building & Code Regulation Division,
2300'Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462.6443
REVIEW COMMENTS
Page 2
Comment: PLEASE SHOW COMPLIANCE WITH SECTION 403.1.3 POTTY PARITY ,FBCP2010 (IN OCCUPANCIES
4/15/2014 RESTROOMS WICH ARE OPEN TO THE PUBIC MUST HAVE A RATIO OF 3:2 WATERCLOSETS PROVIDED
FOR WOMEN AS THE COMBINED TOTAL OF WATER CLOSETS AND URINALS FOR MEN UNLESS THERE ARE
TWO OR FEWER SUCH FIXTURES FOR MEN IN ACCORDANCE WITH SEC 553.86 FLORIDA STATUTES)
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicio 4/14/2014
Comment:
SUBMIT A SIGNED, SEALED AND DATED SOIL TEST SHOWING THAT THE SITE SOILS MEET OR EXCEED
THE ASSUMED DESIGN OF 2,000 P.S.F. * A PAD CERTIFICATION REPORT, APPROVED BY THE DESIGN
4/14/2014
PROFESSIONAL OF RECORD, WILL BE REQUIRED TO BE SUBMITTED FOR REVIEW PRIOR TO ANY
FOUNDATION INSPECTIONS
Comment:
SUBMIT ENGINEERED, TRIPLICATE SETS OF ORIGINAL STRUCTURAL STEEL PLANS FROM THE
4/14/2014
STRUCTURAL STEEL ENGINEER * THESE MUST BE REVIEWED AND APPROVED BY YOUR DESIGN
PROFESSIONAL OF RECORD
Comment:
SUBMIT THE WOOD TRUSS LAYOUTS AND SIGNED, SEALED AND DATED CUT SHEET ENGINEERING FROM
THE TRUSS MANUFACTURER IN TRIPLICATE * ALL MUST BE REVIEWED AND APPROVED BY THE DESIGN
4/14/2014
PROFESSIONAL OF RECORD
Comment:
THIS PROJECT IS A THRESHOLD BUILDING BY STATUTE AND F.B.C. 110.3.7 :: SUBMIT A LETTER OF
INTENT SIGNED, DATED AND SEALED BY THE SPECIAL INSPECTOR WHO WILL BE PERFORMING THE
SPECIFIED INSPECTIONS AND INCLUDE THE BN NUMBERS OF THE FIELD INSPECTORS WHO WILL BE ON
4/14/2014
SITE ** SUBMIT DUPLICATE, SEALED STRUCTURAL INSPECTION PLANS PREPARED BY THE ARCHITECT OR
ENGINEER OF RECORD PROVIDING SPECIFIC INSPECTION PROCEDURES AND SCHEDULES FOR
COMPLIANCE WITH THE APPROVED PLANS.
Comment:
SUBMIT A NOTARIZED LETTER FROM THE FEE OWNER OF THE BUILDING STATING THAT HE/SHE HAS
4/14/2014
HIRED THE SPECIAL INSPECTOR TO PERFORM THE SPECIFIED STRUCTURAL INSPECTIONS
Comment:
INCLUDE THE CURRENT 2009 EDITION OF THE LIFE SAFETY CODE IN THE CODE INFORMATION BOX AND
4/14/2014
SUBMIT [ 3 ] LIFE SAFETY PLANS IN CONFORMANCE WITH NFPA 101 7.6.1 TRAVEL DISTANCE
SPECIFICATIONS * USE THE 12" RULE AND NO DIAGONALS
4/23/2014 Comment:
WIND PRESSURE DIAGRAMS ON STRUCTURAL / SO-1 MUST RELATE TO THE ACTUAL BUILDING
DIMENSIONS [ NOT GENERIC ]
4/2312014 Comment:
SUBMIT THE STRUCTURAL DESIGN FOR THE LIGHT GAUGE METAL FRAMING REVIEWED AND APPROVED
BY THE DESIGN PROFESSIONAL OF RECORD
Comment:
DESIGN PROFESSIONAL TO CORRECT THE OCCUPANCY TYPES ON AO.1 * ONLY USE THE
4/23/2014
CLASSIFICATIONS AS SPECIFIED IN F.B.C. TABLE 1004.1.1 * CHECK OTHER STORAGE AREAS ?? AND
CIRCULATION / MECH/RESTROOM AND ELECTRIC ??? [ SEE NET AREA DEFINITION ] PLS CLARIFY
BUILDING OCCUPANCY "F"
4/24/2014 Comment:
SUBMIT TRIPLICATE " ST LUCIE COUNTY CERTIFICATION FOR DESIGN LOAD COMPLIANCE " SHEETS
COMPLETELY FILLED OUT / SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL OF RECORD
4/24/2014 Comment:
SUBMIT TRIPLICATE SIGNED, SEALED AND DATED " PRODUCT REVIEW AFFIDAVITS " COMPLETELY
FILLED OUT AS SPECIFIED FOR ALL BUILDING CLADDING
4/24/2014 Comment:
SUBMIT THE MANUFACTURERS SPECIFICATIONS FOR THE FIREPLACES REVIEWED AND APPROVED BY
THE DESIGN PROFESSIONAL OF RECORD
4/24/2014 Comment:
SUBMIT THE ENGINEERED SHOP DRAWINGS IN TRIPLICATE FOR THE WALK IN COOLER WITH THE
ANCHORING TO THE FOUNDATION
4/24/2014 Comment:
SUBMIT IN TRIPLICATE, ACCESSIBLE ROUTE PLANS [ SEE FBC ACCESSIBILITY ] CHAPTER 4
4/24/2014 Comment:
SHEET A3.5 / DETAIL 2 SHOWS A SHIPS LADDER MOUNTED TO LIGHTWEIGHT CONCRETE TOPPING / PLS
LOCATE THIS ON PLANS
4/24/2014 Comment:
SUBMIT THE ENGINEERS SHOPS FOR THE ROOF MECHANICAL SCREENING, REVIEWED AND APPROVED
BY THE DESIGN PROFESSIONAL OF RECORD
4/24/2014 Comment:
DESIGN THE WINDOW AND DOOR BUCK DETAILS ON PLANS
4/24/2014 Comment:
SUBMIT THE MANUFACTURERS SPECIFICATIONS IN TRIPLICATE FOR THE 8' X 8' VINYL FENCE PANELS
ATTACHMENT TO POSTS [ SEE PLAN SHEET H1.1 ] DETAIL 16
ZONING REVIEW
INCOMPLETE Lydia Galbraith 4/11/2014
Comment:
PLEASE BE AWARE THAT WE WERE NOT ABLE TO DO THE ZONING REVIEW DUE TO THE SITE PLAN
4/11/2014
ADJUSTMENT NOT BEING APPROVED YET. THE PLANS WILL BE FORWARDED TO PLAN REVIEW. PLEASE
BE AWARE THAT AFTER FINAL APPROVAL OF THE SITE PLAN ADJUSTMENT ADDITIONAL COMMENTS
FROM ZONING AND/OR OTHER DEPARTMENTS MIGHT BE APPLICABLE.