APPROVED, PV Plans - 121003_Gaunt, John - signed
PV-1 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - THIS PROJECT COMPLIES WITH THE FOLLOWING: 2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL 2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING 2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION 2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY 2020 7TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA) 2017 NATIONAL ELECTRIC CODE (NEC) AS ADOPTED BY ST. LUCIE COUNTY SITE LOCATION CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: PHOTOVOLTAIC SYSTEM PV-1 SITE LOCATION PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B STRUCTURAL CALCULATIONS PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE SITE LOCATION GREG ALBRIGHT PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2017 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. THIS SYSTEM IS DESIGNED FOR WIND SPEED: 15 MPH CATEGORY C EXPOSURE Josep h J Bravo Digitally signed by Joseph J Bravo Date: 2022.01.31 11:49:03 -07'00' MSP INV JB UM AC SITE PLAN SCALE: 1/16" = 1'-0"1 PV-2 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - ROOF AREA: 1893 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT JUNCTION BOX INVERTER MAIN SERVICE PANEL FUSED AC DISCONNECT AC JB INV MSP FAC GREG ALBRIGHTDRIVEWAYPENNY LANE TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 1893 SQ FT SINGLE MODULE AREA: 19.32 SQ FT TOTAL NUMBER OF MODULES: 35 TOTAL AREA OF MODULES: 676.20 SQ FT ROOF COVERAGE: 35.72% FIRE SPRINKLERS : NO BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' THIS SYSTEM DESIGNED WITH: WIND SPEED: 1503+ WIND EXPOSURE: C SNOW LOAD: 0 136'-5"78'-3"53'-11"15'-2"14'-4"43'-6"ROOF LINE PROPERTY LINE (E) MAIN SERVICE PANEL (N) 35 HANWHA QCELL: Q.PEAK DUO-G8+ 350W (E) UTILITY METER (N) JUNCTION BOX (N) SOLAREDGE SE10000H-USRGM [SI1] INVERTER WITH RAPID SHUTDOWN (N) UTILITY DISCONNECT EATON DG222NRB (OR EQUIVALENT) MSP INV JB UM AC PV-2A FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - ROOF PLAN SCALE: 3/16" = 1'-0"1 NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 1893 SQ FT ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT JUNCTION BOX INVERTER MAIN SERVICE PANEL FUSED AC DISCONNECT AC JB INV MSP FAC GREG ALBRIGHT BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10' THIS SYSTEM DESIGNED WITH: WIND SPEED: 1503+ WIND EXPOSURE: C SNOW LOAD: 0 FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS 3'- 0 "3'-0"3' - 0 "3'-0"3'-0" 3'-0" (N) 35 HANWHA QCELL: Q.PEAK DUO-G8+ 350W This item has been electronically signed and sealed by Mehdi Zomorodian, SE,PE. on the date and/or time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified by a 3rd Party Certificate Authority on any electronic copy. S. M. Mehdi Zomorodian Digitally signed by S. M. Mehdi Zomorodian Date: 2022.01.31 22:42:01 -06'00' STRUCTURAL ONLY THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY HUMPHREY K. KARIUKI, P.E. ON THE DATE SHOWN USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 1 15 20° 20° 181°537 SQ FT 289.8 SQ FT 22 20° 20° 91°168 SQ FT 38.64 SQ FT 3 16 20° 20° 1°537 SQ FT 309.12 SQ FT 42 20° 20° 271°159 SQ FT 38.64 SQ FT PV-2B FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - ROOF DETAILS: TOTAL ROOF AREA: 1893 SQ FT ARRAY COVERAGE: 35.72% SYSTEM DISTRIBUTED WEIGHT: 2.27 LBS SFM INFINITY \ ROCKIT MICRORAIL POINT-LOAD: 12.6 LBS ROOF DETAILS GREG ALBRIGHT This item has been electronically signed and sealed by Mehdi Zomorodian, SE,PE. on the date and/or time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified by a 3rd Party Certificate Authority on any electronic copy. STRUCTURAL ONLY THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY HUMPHREY K. KARIUKI, P.E. ON THE DATE SHOWN USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ROOF DECK / MEMBRANE SLIDER AND TRIMRAIL ROOF ATTACHMENT BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" TRIMRAIL 2.5" MIN. EMBED.FLASHING ROOF / DECK MEMBRANE SLIDERS BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" MICRORAIL FLASHING 2.5" MIN. EMBED. HANWHA QCELL: Q.PEAK DUO-G8+ 350W HANWHA QCELL: Q.PEAK DUO-G8+ 350W SLIDERS MICRORAIL 2.5" MI N. E M B E D. 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER TRIMRAIL 2.5" MI N. E M B E D. FLASHING FLASHING SLIDER AND TRIMRAIL ROOF ATTACHMENT 2X6 TRUSS @ 24" O.C. ROOF / DECK MEMBRANE 3" M IN .6" MAX . HANWHA QCELL: Q.PEAK DUO-G8+ 350W SFM INFINITY \ ROCKIT RAIL-LESS RACKING SYSTEM (N) HANWHA QCELL: Q.PEAK DUO-G8+ 350W 2X6 TRUSS @ 24" O.C. ROOF ATTACHMENT 4' ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PARTIAL ROOF FRAMING PLAN Scale: NTS PV-3 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - MOUNTING DETAILS GREG ALBRIGHT MAX ATTACHMENT SPAN - 4' This item has been electronically signed and sealed by Mehdi Zomorodian, SE,PE. on the date and/or time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified by a 3rd Party Certificate Authority on any electronic copy. STRUCTURAL ONLY THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY HUMPHREY K. KARIUKI, P.E. ON THE DATE SHOWN USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. JUNCTION BOX SOLAREDGE P370 POWER OPTIMIZERS STRING-1 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT STRING-3 SOLAREDGE P370 POWER OPTIMIZERS 4 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT 17 HANWHA QCELL: Q.PEAK DUO-G8+ 350W 9 HANWHA QCELL: Q.PEAK DUO-G8+ 350W STRING-2 9 HANWHA QCELL: Q.PEAK DUO-G8+ 350W 2 - #10 AWG, PV WIRE SOLAREDGE P370 POWER OPTIMIZERS 6 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT UM (E) 125A / 2P MAIN BREAKER (END FED) (E) 125A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER (N) LINESIDE TAP VIA UL LISTED CONNECTORS 1 - #6 GEC, BARE COPPER FREE AIR BONDED EXISTING UFER TIE IN TO UTILITY UNDERGROUND FEED (N) 60A FUSED AC DISCONNECT EATON DG222NRB (OR EQUIVALENT) 2 - 60 AMP FUSES 3 - #6 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDE TAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITE CONDITIONS. 3 - #6 AWG, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) SOLAREDGE SE10000H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 42.00A @ 240V 42.00 X 1.25 = 53AMPS 60A FUSES - OK PV SYSTEM 12.250 kW-DC 10.000 kW-AC PV-4 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - THREE LINE DIAGRAM GREG ALBRIGHT PV-5 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT WIRE LOCATION CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO OPTIMIZER ROOF / FREE-AIR 210 40 13.43 1 1 40.00 16.78 2 DC OPTIMIZER TO JUNCTION BOX ROOF / FREE-AIR 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER EXTERIOR WALL 6 10 40 15.00 1 0.8 32.00 18.75 4 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 6 75 42.00 1 1 75.00 52.50 5 AC AC DISCONNECT TO POI EXTERIOR WALL 36 75 42.00 1 1 75.00 52.50 CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST: PV-6 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - QTY.PART PART # DESCRIPTION 35 MODULES 111-350 HANWHA QCELL: Q.PEAK DUO-G8+ 350W 35 OPTIMIZERS 130-370 SOLAREDGE P370 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE) 2 CONNECTORS 240-301 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE) 1 INVERTER 120-103 SOLAREDGE SE10000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 323-061 60A RATED 240VAC NEMA 3R UL LISTED 2 FUSES 330-060 60A FUSE 1 PH 240VAC 1 FUSE REDUCER 330-510 100A-60A FUSE REDUCER 122 ROOF ATTACHMENT 1 261 -602 SFM INFINITY \ ROCKIT MICRORAIL 25 SFM TRIM 1 241-253 FLASHKIT SFM / ROCK-IT TRIM COMP DARK 66 SFM SLIDER 1 261-603 FLASHKIT SFM / ROCK-IT SLIDER COMP DARK 20 BONDING CLAMP 1 221-100 N/S BONDING CLAMP 8 BONDING CLAMP 1 241-404 TRIM BONDING CLAMP 37 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 21 SFM SPLICE 1 261-604 SFM / ROCK-IT SPLICE 5 SFM ATTACHED SPLICE 1 211-101 ATTACHED SPLICE 8 INCH 29 TRIMRAIL 1 261-606 TRIMRAIL UNIV CLIP W/ HDW 9 TRIM SPLICE 1 261-605 TRIM SPLICE DRK 16 TRIMRAIL 1 211-115 TRIMRAIL UNIV DRK 35 GROUND LUG 1 260-585 ILSCO GROUND LUG 35 TRIM END CAPS 1 221-200 UNIRAC SFM / ROCK-IT TRIM END CAPS BREAKER SIZES:SERVICE LIST: NONE EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES:M 690.54 705.12(B)(2)(3)(b) "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 42.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS WARNING: POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 690.56(C)(1)(A) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC 690.15, 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 42.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3) INVERTER ARRAY J/BDC "WARNING" ELECTRICAL SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 690.13 (B) 690.53 NEC 690.31(G)(3) & (4)PMPV METER SOLAR ELECTRIC PV PANELS PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE: 480V MAXIMUM CIRCUIT CURRENT: 27A MAX RATED OUTPUT CURRENT OF THE CONTROLLER OR DC-TO-DC CONVERTER: 15A TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM NFPA 11.12.2.1.1.1.1 SOLAR ELECTRIC PV PANELS EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION. ONLY CONDUCTORS INSIDE BUILDING OR OFF THE ROOF WILL SHUT DOWN NFPA 11.12.2.1.1.1.2 SOLAR ELECTRIC PV PANELS EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN "WARNING" PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES PV-7 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - LABELS GREG ALBRIGHT 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. ARIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS CAUTION: POWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWN PV-7A FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N MAIN SERVICE PANEL AC DISCONNECT INVERTER EQUIPPED WITH RAPID SHUTDOWN UTILITY METER PENNY LANE 35 PV MODULES 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 PV-8 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET IN CASE OF EMERGENCY NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC NAME: _______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O PV-9 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT PENNY LANE JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access x Ladders must be inspected before each use. x Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. x Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. x A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). x Additional notes: Mobile Equipment x Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. x Type(s) of mobile equipment (Type/Make/Model): x Qualified operator(s): Material Handling and Storage x Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection x A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. x First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. x FPCP (name and title): x FPU and LPD (name and title): Electrical Safety x The Electrical Qualified Person (EQP) is required onsite to perform electrical work. x All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. x Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. x EQP (name and tile): Public Protection x The safety of the Client and Public must be maintained at all times. x The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. x Company, Client and Public property shall be protected from falling objects. x Pets (including dogs) shall be secured by their owners prior to work start. x The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. x Crew leader responsible for communication with the client: x Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing x All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. x Crew leader (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): Airborne Contaminants: x Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) x Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. x If yes, list specific tasks and protection in place: Weather and Environment x The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) x The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. x Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. x Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention x Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. x Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. x New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. x Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. x Cool Vests are encouraged for all employees at all times during periods of high heat. x Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? x If offsite replenish is necessary, where will you go to replenish water (location/address): x Who will replenish the drinking water (name): Restroom facilities x Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. x Restroom facilities will be (circle one): Onsite - Offsite x If Offsite, add location name and address: Incident Reporting Procedure x Contact your Site Supervisor Name: Phone: x Contact your Manager Name: Phone: x Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: F121003 DESIGNED BY: H.D. CLIENT: JOHN GAUNT 7703 PENNY LANE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (772) 708-0384 SYSTEM: SYSTEM SIZE (DC): 35 X 350 = 12.250 kW SYSTEM SIZE (AC): 10.000 kW @ 240V MODULES: 35 X HANWHA QCELL: Q.PEAK DUO-G8+ 350W OPTIMIZERS: 35 X SOLAREDGE P370 INVERTER: SOLAREDGE SE10000H-USRGM [SI1] DATE: 1/31/2022 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT POWER OPTIMIZERPower Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 solaredge.com PV power optimization at the module level 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK6RODU(GJHLQYHUWHUV 1H[WJHQHUDWLRQPDLQWHQDQFHZLWKPRGXOHOHYHO PRQLWRULQJ 0RGXOHOHYHOYROWDJHVKXWGRZQIRULQVWDOOHUDQG ÀUHÀJKWHUVDIHW\ 6XSHULRUHIÀFLHQF\ 8SWRPRUHHQHUJ\ 0LWLJDWHVDOOW\SHVRIPRGXOHVPLVPDWFKORVVIURP PDQXIDFWXULQJWROHUDQFHWRSDUWLDOVKDGLQJ )DVWLQVWDOODWLRQZLWKDVLQJOHEROW )OH[LEOHV\VWHPGHVLJQIRUPD[LPXPVSDFHXWLOL]DWLRQ 25 YEARWARRANTY Power Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 6RODU(GJH7HFKQRORJLHV/WG$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQ DUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*52:6XEMHFWWRFKDQJHZLWKRXWQRWLFH 5DWHGSRZHURIWKHPRGXOHDW67&ZLOOQRWH[FHHGWKHRSWLPL]HU´5DWHG,QSXW'&3RZHUµ0RGXOHVZLWKXSWRSRZHUWROHUDQFHDUHDOORZHG )RURWKHUFRQQHFWRUW\SHVSOHDVHFRQWDFW6RODU(GJH )RUGXDOYHUVLRQIRUSDUDOOHOFRQQHFWLRQRIWZRPRGXOHVXVHWKH3,QWKHFDVHRIDQRGGQXPEHURI39PRGXOHVLQRQHVWULQJLQVWDOOLQJRQH3GXDOYHUVLRQSRZHURSWLPL]HUFRQQHFWHGWR RQH39PRGXOHLVVXSSRUWHG:KHQFRQQHFWLQJDVLQJOHPRGXOHVHDOWKHXQXVHGLQSXWFRQQHFWRUVXVLQJWKHVXSSOLHGSDLURIVHDOV OPTIMIZER MODEL (typical module compatibilty) P370 (60/72 Cell modules) P401 (For high power 60/72-cell modules) P404 (for 60/72- cell short strings) P405 (for high-voltage modules) P485 (for high-voltage modules) P500 (for 96-cell modules) P505 (for higher current modules) UNIT INPUT 5DWHG,QSXW'&3RZHU370 400 405 405 485 500 505 : $EVROXWH0D[LPXP,QSXW9ROWDJH 9RFDWORZHVWWHPSHUDWXUH80 80 83 9GF 03372SHUDWLQJ5DQJH 9GF 0D[LPXP6KRUW&LUFXLW&XUUHQW,VF11 11.75 11 10.1 14 $GF 0D[LPXP(IÀFLHQF\ :HLJKWHG(IÀFLHQF\ 2YHUYROWDJH&DWHJRU\,, OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 0D[LPXP2XWSXW&XUUHQW 15 $GF 0D[LPXP2XWSXW9ROWDJH 85 85 9GF OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 6DIHW\2XWSXW9ROWDJHSHU3RZHU 2SWLPL]HU 1 ± 0.1 9GF STANDARD COMPLIANCE (0& )&&3DUW&ODVV%,(&,(& 6DIHW\,(&FODVV,,VDIHW\8/ 5R+6 <HV )LUH6DIHW\9'($5( INSTALLATION SPECIFICATIONS 0D[LPXP$OORZHG6\VWHP9ROWDJH 1000 9GF 'LPHQVLRQV:[/[+[[ [[ [[ [[ [[ [ x 1.7 [[[[ [[ [ x 1.3 [[ [ [ mm LQ :HLJKWLQFOXGLQJFDEOHV 775 / 1.7 750 / 1.7 JUOE ,QSXW&RQQHFWRU 0& 6LQJOHRU 'XDO0&0& ,QSXW:LUH/HQJWK PIW 2XWSXW&RQQHFWRU 0& 2XWSXW:LUH/HQJWK PIW 2SHUDWLQJ7HPSHUDWXUH5DQJH Ü&Ü) 3URWHFWLRQ5DWLQJ ,3 5HODWLYH+XPLGLW\ PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(4)(5) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE THREE PHASE FOR 277/480V GRID 0LQLPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV 3338 18 3333 ZLWK6(. 14 0D[LPXP6WULQJ/HQJWK3RZHU2SWLPL]HUV 50 50 0D[LPXP3RZHUSHU6WULQJ 5700 : 3DUDOOHO6WULQJVRI'LIIHUHQW/HQJWKVRU2ULHQWDWLRQV <HV ,WLVQRWDOORZHGWRPL[3333ZLWK33333333S33LQRQHVWULQJ )RU6(NDQGDERYHWKHPLQLPXP'&SRZHUVKRXOGEH.: 7KH333FDQQRWEHXVHGZLWKWKH6(.WKUHHSKDVHLQYHUWHUDYDLODEOHLQVRPHFRXQWULHVUHIHUWRWKHWKUHHSKDVHLQYHUWHU6(.6(.GDWDVKHHW ([DFWO\ZKHQXVLQJ6(.5:%11 )RUWKH9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGLIHUHQFHEHWZHHQHDFKVWULQJLV: )RUWKH9JULGLWLVDOORZHGWRLQVWDOOXSWR:SHUVWULQJZKHQWKHPD[LPXPSRZHUGLIHUHQFHEHWZHHQHDFKVWULQJLV: Take your business to the next level with SFM INFINITY, UNIRAC’s rail-less PV mounting system for flush mount installations on comp shingle and tile roofs. An advanced 3rd generation product platform in use by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional solar racking. Plus, 87% of homeowners prefer SFM INFINITY’s aesthetics. SUPERIOR PERFORMANCE Enhance your business with two installs per day and 30% less cost. EASY INSTALLATION Pre-assembled components, 20% fewer roof attachments, and level array in seconds with post height adjustment. HOMEOWNER PREFERRED More than 4 out of 5 homeowners prefer SFM INFINITY’S aesthetics over a leading rail brand. SFM INFINITY FRONT TRIM AND END CAPS UNIVERSAL COMPONENTS FIT 32 – 40MM MODULES EOWNER PREFERRED 25 YEAR FULL-SYSTEM WARRANTY ONE SKU FITS 32 TO 40mm REVOLUTIONIZING ROOFTOP SOLAR FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 REVOLUTIONIZING ROOFTOP SOLAR FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 SFM INFINITY DESIGN GUIDELINES APPLICATION GUIDE While you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you to maximize its benefits. When possible, design in landscape orientation in order to fit more modules on the roof and minimize roof attachments. DEFAULT TO LANDSCAPE SFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array density and to avoid vent pipes and other obstacles. Because mounting locations are not constrained by rails, SFM INFINITY has unmatched flexibility to enhance your projects. MIX MODULE ORIENTATIONS Visit UNIRAC’s mobile-friendly library of short, topic-specific videos which answer common questions and demonstrate how simple it is to install SFM INFINITY. CONSULT THE QUICK TIPS VIDEOS Quick Tips Videos: https://unirac.com/SFM-Infinity/ Layout your arrays in U-Builder, UNIRAC’s free solar design software, to optimize SFM INFINITY’S capabilities, including mixing module orientations and minimizing roof attachments. Quickly create layouts on Google or Bing Maps and generate project documents. DESIGN IN U-BUILDER U-Builder: https://design.unirac.com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ϸ 8/'HVLJQ/RDG5DWLQJ36)'RZQZDUG36)8SZDUG36)'RZQ6ORSH 7HVWHG/RDGVSVI3D'RZQZDUGSVI3D8SOLIWSVI3D'RZQ6ORSH 7ULQD7603'DQG6XQSRZHU635(XVHGIRU0HFKDQLFDO/RDGLQJ ,QFUHDVHGVL]H0/WHVW 0D[LPXP0RGXOH6L]HIWð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´JDSEHWZHHQWKHERWWRPRIWKHPRGXOHDQGWKHURRI¶V VXUIDFH See section 7.0 illustraction # 1 and 1a for a complete list of PV modules evaluated with these racking systems 5DWLQJV 1$ ('$SU0DQGDWRU\ Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 1 of 3 GFT-OP-10a Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: x Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. x Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: x Power optimizers: o PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 850. SP followed by 001 to 350. *When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019 , modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. x 1-ph Inverters: Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 2 of 3 GFT-OP-10a o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix x 3-ph Inverters: o SE9KUS / SE10KUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS /SE43.2KUS / SE66.6KUS / SE100KUS ; when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. '4'5HY 3DJH &HUWLILFDWHRI&RPSOLDQFH &HUWLILFDWH 0DVWHU&RQWUDFW 3URMHFW 'DWH,VVXHG ,VVXHGWR 8QLUDF %URDGZD\1( $OEXTXHUTXH1HZ0H[LFR 86$ $WWHQWLRQ .ODXV1LFRODHGLV The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. ,VVXHGE\Michael Hoffnagle 0LFKDHO+RIIQDJOH 352'8&76 &/$66&32:(56833/,(63+27292/7$,&6395DFNLQJ &/$66&32:(56833/,(63+27292/7$,&6395DFNLQJDQGFODPSLQJV\VWHPV&HUWLILHGWR 866WDQGDUGV 0RGHOV6062/$502817)OXVKWR5RRILVDQH[WUXGHGDOXPLQXPUDLO39UDFNLQJV\VWHPWKDWLVLQVWDOOHG SDUDOOHOWRWKHURRILQODQGVFDSHRUSRUWUDLWRULHQWDWLRQV 8/$8QLUDF/DUJH$UUD\LVDJURXQGPRXQWV\VWHPXVLQJWKH6RODU0RXQW60SODWIRUPIRUWKH ERQGLQJDQGJURXQGLQJRI39PRGXOHV 62/$502817 7KHV\VWHPOLVWHGLVGHVLJQHGWRSURYLGHERQGLQJJURXQGLQJDQGPHFKDQLFDOVWDELOLW\IRUSKRWRYROWDLFPRGXOHV 7KHV\VWHPLVVHFXUHGWRWKHURRIZLWKWKH/)RRWFRPSRQHQWVWKURXJKWKHURRILQJPDWHULDOWREXLOGLQJVWUXFWXUH 0RGXOHVDUHVHFXUHGWRWKHUDFNLQJV\VWHPZLWKVWDLQOHVVVWHHORUDOXPLQXPPLGFODPSVDQG$OXPLQXPHQG FODPSV7KHPRGXOHVDUHERQGHGWRWKHUDFNLQJV\VWHPZLWKWKHVWDLQOHVVVWHHOERQGLQJPLGFODPSVZLWKSLHUFLQJ SRLQWV7KHV\VWHPLVJURXQGHGZLWK$:*FRSSHUZLUHWRERQGLQJJURXQGLQJOXJV)LUHUDWLQJVRI&ODVV$ ZLWK7\SHRUIRUVWHHSVORSH7HVWHGDW´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ð 8SZDUG'HVLJQ/RDGOEIWð 'RZQ6ORSH/RDGOEIWð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´DQG´GLDPHWHU 7KHPHFKDQLFDOORDGUDWLQJVIURPWKH60WHVWGDWDZLOOEHDSSOLHGWRWKH8/$PRGHO )LUH7HVWLQJLVQRWDSSOLFDEOHGXHWREHLQJDJURXQGPRXQWV\VWHP $33/,&$%/(5(48,5(0(176 8/VW(GLWLRQ0RXQWLQJ6\VWHPV0RXQWLQJ'HYLFHV&ODPSLQJ5HWHQWLRQ'HYLFHVDQG*URXQG /XJVIRU8VHZLWK)ODW3ODWH3KRWRYROWDLF0RGXOHVDQG3DQHOV /75$(/LVWRI7HFKQLFDO5HTXLUHPHQWVIRU3KRWRYROWDLF0RGXOHDQG3DQHOUDFNLQJ6\VWHPV 0$5.,1*6 7KHPDQXIDFWXUHULVUHTXLUHGWRDSSO\WKHIROORZLQJPDUNLQJV x3URGXFWVVKDOOEHPDUNHGZLWKWKHPDUNLQJVVSHFLILHGE\WKHSDUWLFXODUSURGXFWVWDQGDUG x3URGXFWVFHUWLILHGIRU&DQDGDVKDOOKDYHDOO&DXWLRQDQG:DUQLQJPDUNLQJVLQERWK(QJOLVKDQG)UHQFK AUTHORIZATION TO MARK Applicant: Manufacturer: Address: Address: Country: Country: Contact: Contact: Phone: Phone: FAX: FAX: Email: Email: Standard(s): Product: Brand Name: Models: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Unirac SFM Unirac Control Number:5003705 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. klaus.nicolaedis@unirac.com toddg@unirac.com jia.liu@cxymj.com buwan.luo@cxymj.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Lake Forest, CA U.S.A. Klaus Nicolaedis Tom Young Jia Liu Robin Luo 505-462-2190 505-843-1418 +86-15267030962 +86-13621785753 NA NA Unirac, Inc Cixi Emeka Aluminum Co. Ltd 1411 Broadway Blvd NE Albuquerque, NM 87102 No. 688 ChaoSheng Road Cixi City Zhejiang Province 315311 USA China This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 1 ATM for Report 102393982LAX-002 ATM Issued: 9-Apr-2019 ED 16.3.15 (20-Apr-17) Mandatory This supersedes and replaces in its entirety all previously published versions of this document. T1470 (Last revised on 03.19.19) POLYURETHANE SEALANT & ADHESIVE 915 DESCRIPTION 915 sealant is a one-component, smooth polyurethane adhesive capable of dynamic joint movement totaling 70% of original joint geometry (±35%). The sealant cures to a tough, flexible rubber when exposed to moisture present in the atmosphere. Bostik 915 all seasons formula has physical properties that will remain relatively stable over time. The cured performance temperature range is -400F to 1500F. Where textured appearance is needed, please use Bostik 916. APPLICABLE STANDARDS • ASTM C920, TYPE S, GRADE NS, CLASS 35 USE NT, A AND M • US Federal Specification TT-S 00230C (COMB-NBS) for one-component sealants as Class A, non-sag • CARB, SCAQMD, and OTC compliant • Canadian Specification CAN /CGSB 19.13-M87 • Miami-Dade County, Florida, NOA No.: 13.0423.10, 05/24/17 • Miami-Dade TAS 102- Static Uplift Resistance • AAMA 808.3 • AAMA 100/200/300 installation requirements BASIC USES 915 is designed for applications from foundation to finish and is ideal for, sealing expansion and control joints, tilt up joints, perimeters of doors, windows, and other wall penetrations. It has tenacious sealing and bonding performance for many roofing applications, metal roofs, gutters, roof tile installations, flashing and sheet metal applications. 915 cures to form a durable, flexible bond with most building materials such as stone, foam, masonry, ceramic, wood, steel, Kynar® coated metals and copper and most other metals. INSTALLATION PROTOCOL Miami-Dade County Considerations: Mate or join adjacent surfaces prior to the Bostik 915 skinning and subsequent curing, to maximize wetting potential of the sealant to the substrates. Allow full-cure, typically 7 days, prior to any mechanical stress testing procedures. It is recommended that adhesion testing be performed to capture batch control qualities of proposed substrates. Joint Design: In general, more joint movement can be accommodated in a thin bead of sealant than a thick bead. Bostik 915 should be no thicker than 1/2" (12.7mm) and no thinner than 1/4" (6.4mm). In joints between 1/2" and 1", the ratio of sealant width to depth should be approximately 2:1. Sealant depth in joints between 1/4" and 1/2" should be 1/4" deep. Joints with dynamic movement should not be designed in widths less than 1/4". Surface Preparation: Surfaces must be structurally clean, dry (no frost) and structurally sound, free of contaminants, including, but not limited to, dust, dirt, loose particles, tar, asphalt, rust, mill oil, etc. If substrate is painted or coated, scrape away all loose and weakly bonded paint or coating. Any paint or coating that cannot be removed must be tested to verify adhesion of the sealant or to determine the appropriate surface preparation if needed. (See ASP section on next page for details.) Backer Rods and Bond Breaker Tapes: Bond breakers including, but not limited to, closed-cell polyethylene backer rods are used to control depth of the sealant bead, provide a firm tooling surface KEY FEATURES – Tenacious bond to difficult substrates – Permanently flexible – Miami-Dade approval NOA 17-0329.18, 15-0520.01 and avoid three-sided adhesion. Where the depth of joint prevents use of backer rods, a polyethylene strip or tape must be used as a bond breaker to prevent 3-sided adhesion. Do not prime or damage the surface of the bond breaker. Refer to instructions given by rod and tape manufacturers for the correct backer rod and tape size related to joint size. Tooling: 915 comes ready-to-use. Cut spout or tip to desired bead size. Apply moderate pressure to break seal inside the nozzle. Apply by using a professional caulking gun. Use opened cartridges and sausages the same day they are opened. Apply 915 in a continuous operation using positive pressure to the bottom of the joint to properly fill and seal the joint. When applying, avoid air entrapment and overlapping. Tool the sealant before the skin forms with adequate pressure to spread the sealant against the backup material at the bottom and sides of the joint. A dry tool with a concave profile is recommended for that operation. Do not use water or soapy water for this operation. Avoid smearing and feathering of the sealant to allow full performance of the cured seam. Excess sealant should be dry-wiped or joints should be properly taped. Cleaning: After dry-wiping uncured sealant from substrates and tools, remaining uncured sealant can be removed by using mineral spirits. Cured sealant is usually very difficult to remove without altering or damaging the surface to which the sealant has been misapplied. Cured sealant can be removed by abrasion or other mechanical means (scrapers, putty knives). Curing Time: 915 is a moisture cure, Polyurethane Sealant. On wood, with ambient air at 50% relative humidity and at 73°F, polyurethane sealants will generally skin within four hours and cure 1/16 of an inch per day. Lower temperature and lower relative humidity will significantly increase the skin time and cure time of a polyurethane sealant. Painting and Coating: Do not paint over the polyurethane sealant until it has fully cured. Maintenance: If the sealant becomes damaged, replace the damaged portion by removing the old sealant completely, cleaning the surfaces and reapplying a fresh and appropriate amount of new sealant in accordance with the directions and information contained in this data sheet. MANDATORY ADHESION TO SUBSTRATES PRETEST - (ASP) A hand pull test must be run before the job starts and at regular intervals during the job. It must be run on the job site after the sealant is fully cured, usually within 7 to 21 days. (Adhesion may develop fully after at least 14 days.) The hand pull test procedure is as follows: 1. Make a knife cut horizontally from one side of the joint to the other. 2. Make two vertical cuts approximately two inches long, at the sides of the joint, meeting the horizontal cut at the top of the two-inch cuts. 3. Grasp the two-inch piece of sealant firmly between the fingers and pull down at a 90° angle or more, and try to pull the uncut sealant out of the joint. 4. If adhesion is sufficient, the sealant should tear cohesively in itself. 5. Sealant may be replaced by applying more sealant in the same manner as it was originally applied. Care should be taken to ensure that the new sealant is in contact with the original, and that the original sealant surfaces are clean, so that a proper bond between the new and old sealant will be obtained. PACKAGING 10.1 fl. oz. Cartridges, 24 Cartridges/Case 20 fl. oz. Sausages, 12 Sausages/Case COLORS White, Black, Light Gray, Stone, Aluminum Stone, Limestone, Bronze, Medium Bronze, Terra Cotta, and Tan AVAILABILITY Available from authorized Bostik distributors. Go to www.bostik.com/us and check on our distributor locator for the closest distributor in your location or call customer service at 1-800-7/BOSTIK (1-800-726-7845). STORAGE/SHELF LIFE Store in a clean, dry area not affected by freezing or hot temperatures between 50°F (10°C) and 90°F (32°C). Shelf life is one year from date of manufacturing in unopened cartridge. LIMITATIONS • Construction substrates have become complex and diverse by nature and origin. Substrate chemistries and structures can interfere with adhesive performances of the sealant. Adhesion to Substrate Pretest (ASP) is therefore MANDATORY to assess any adhesion and sealing characteristics — see Adhesion to Substrates Pretest section and see Installation Protocol section. This must be done pre-installation to avoid potential failures. Call Technical Service for more information about surface preparation. • Do not apply over damp, contaminated, loose surfaces, old sealants or other foreign substances that may impair the adhesion bond. Avoid air entrapment. • Dampness and substrates with high moisture content will trigger extensive curing of the sealant within a very short period of time. This may cause an excess of bubbling and foaming within the sealant and at the bottom of the bead. • High temperature/humidity can cause the sealant to develop bubbles during the curing process. • Sealant installation is not recommended when the dew point of the substrate is close to ambient temperature or a moisture-vapor transmission condition is present increasing the potential for bubbling to form during cure. MANDATORY ADHESION TO SUBSTRATE (ASP) FIELD TEST SEALANT MUST REMAIN ON BOTH SIDES2"KNIFE CUT BOTH SIDES OF JOINTBACKER ROD • Porous substrates such as, but not limited to, marble, limestone, and granite might absorb components of the 915 leading to staining of the substrate. ASP with sufficient aging is mandatory to assess this potential issue. • 915 must not be used to seal narrow joints, fillet joints and face nail holes. • Smearing and feathering 915 over joints is not recommended. • 915 is not recommended for horizontal joints or traffic-bearing joints where abrasion resistance is required (walkways, driveways, runways, etc.). Please refer to Bostik 955-SL™ for this application. • 915 is not recommended for continuous immersion in water or any other fluid. When fully cured, avoid exposure, even incidental, to fuels, chlorinated, acid and alkaline solutions. Bostik 915 is not recommended for exterior or interior sealing below the waterline; please refer to Bostik 940 Fast Set for marine applications. • Contact of 915 with asphalts (i.e., back coating of window flashing, etc.) and other filler compounds impregnated with oil, asphalt, tar, etc., may deteriorate the cohesive strength of the substrate and ultimately compromise the seal. Please refer to PRO MS 50™ for asphalt applications. • Lower relative humidity and temperature will significantly extend the curing time. Confined areas, deep joints and moisture barrier substrates may also affect the full cure time and extend it by many days. Apply sealant in ambient air temperature of 40° F (4.4°C). and rising. • 915 may remain tacky for a few hours and attract dust and dirt from the jobsite which may affect the appearance of the sealant. Check tack-free time to prevent dirt pickup. • 915 is not recommended for glazing applications. Bond line strength can be affected by UV rays through the clear material (glass, acrylic glass, polycarbonate, etc.). • Do not paint over the polyurethane sealant until it has fully cured. • The surface of a 915 seal when exposed to UV rays and sunlight will yellow and will not retain its gloss. This phenomenon can occur within a few weeks after exposure. The change of color is limited to the surface layer of the seal and should not compromise the sealing properties of the 915 if the dimensions of the joint are proper and the sealant is otherwise properly applied. In areas where color retention is critical, please refer to Bostik PRO MS 50™. CAUTION IRRITANT. MAY BE HARMFUL IF SWALLOWED OR INHALED. CONTAINS POTENTIAL SENSITIZER. MAY CAUSE ALLERGIC SKIN OR LUNG REACTION. MAY IRRITATE EYES, SKIN AND RESPIRATORY TRACT. Do not breathe fumes. Do not get in eyes, on skin or on clothing. Do not swallow. Use only in a well-ventilated area or wear mask. Wash thoroughly after handling. Store container in a cool, dry area with lid tightly sealed. Do not reuse container. KEEP OUT OF REACH OF CHILDREN TABLE 1: TYPICAL UNCURED PROPERTIES* Property Value Test Method/Note Tool/Work Time 60 min. Bostik Test Method Skin Time 4 Hours Bostik Test Method Curing Time @770F (250C)2-7 days Varies w/relative humidity Flow, Sag or Slump 0.3 inch Bostik Test Method * Values given above are not intended to be used in specification preparation purposes. TABLE 2: TYPICAL CURED PROPERTIES* (AFTER 14 DAYS CURE AT 77°F AND 50% RH) Property Value Test Method/Note Hardness (Shore A) 42 ASTM D 2240 Modulus @ 100% Elongation @ 25% Elongation 65 psi 45 psi ASTM D 412 ASTM D 412 Tensile Strength @ Break 133 psi ASTM D 412 Elongation @ Break 685%ASTM D 412 Adhesion Peel >5 piw TT-S-00230C / ASTM C 794 Joint Movement Capability +/- 35%TT-S-00230C / ASTM C 719 UV Resistance Pass ASTM C 793 Static Uplift Resistance (concrete roof tile)49 Miami-Dade TAS 102 * Values given above are not intended to be used in specification preparation purposes. COVERAGE FOR 10.1 FL. OZ. (300 ML) CARTRIDGE Width Depth 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1/8" 99 49 33 24 20 16 14 12 1/4" 24 20 12 10 8 7 6 3/8" 1186554 1/2" 6 5 4 3 3 Linear Feet Per 10.1 fl. oz. Cartridge COVERAGE FOR 20 FL. OZ. (600 ML) SAUSAGE Width Depth 1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1/8" 288 145 95 71 58 48 40 36 1/4" 71 58 36 29 23 20 17 3/8" 32 23 17 16 13 11 1/2" 17 14 11 10 8 Linear Feet Per 20 fl. oz. Sausage BOSTIK HOTLINE Bostik, Inc. 11320 W. Watertown Plank Road Wauwatosa, WI 53226 www.bostik.com/us Smart help 1-800-726-7845 FIRST AID TREATMENT Contains petroleum resins, diisodecyl phthalate (DIDP), methylene diphenyl isocyanate (MDI), quartz silica. Methanol may form during curing. If in eyes or on skin, rinse with water for at least 15 minutes. If on clothes, remove clothes. If breathed in, move person to fresh air. If swallowed, call a Poison Control Center or doctor immediately. Do not induce vomiting. SEE SAFETY DATA SHEET CHEMICAL EMERGENCY: 800-424-9300 (USA), 703-527-3887 (International) MEDICAL EMERGENCY: 866-767-5089 LIMITED WARRANTY It is the buyer’s obligation to test the suitability of the product for an intended use prior to using it. The Limited Warranty extends only to the original purchaser and is not transferable or assignable. Any claim for a defective product must be filed within 30 days of discovery of a problem, and must be submitted with written proof of purchase. Limited Warranty found at www.bostik.com/us or call 800.726.7845. TO THE MAXIMUM EXTENT ALLOWED BY LAW, BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED WARRANTY, THE SOLE REMEDY FOR BREACH OF WARRANTY IS REPLACEMENT OF THE PRODUCT OR CREDIT OF THE BUYER’S PURCHASE PRICE. BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT, INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES TO THE MAXIMUM EXTENT ALLOWED BY LAW. DISCLAIMERS OF IMPLIED WARRANTIES MAY NOT BE APPLICABLE TO CERTAIN CLASSES OF BUYERS AND SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.