Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revision - 11-20-14
OFFICE USE ONLY: DATE FILED: kz PERMIT # REVISION FM.--, RECEIPT # � (77� I. LOCATION/SITE x` ADDRESS: i 1 -k? `t' - i c 12 . r ► 6 L-L)e.,E 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. 4. 5. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: ST. LUCIE COUNTY CERT. #:-iA� STATE: FAX: NAME: ADDRESS: CITY: iia : 1�stw f PHONE: (� d (� - f aro ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): Revised 07/22/2014 ZIP: STATE: F-L z_ _ ZIP: 2041d 4. FAX: LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURE€t CATALOG NUMBER LAMP VOLTS MTG_ NOTES SIZE QUAN. A WILLIAMS 50G-S24-232-5-A12125-EB2-UNV 32WT8 - 3000K 2 MT RECESSED 2x4 FLUOR. TROFFER - NOTE 3 8 WILLIAMS 17-2-217-A-EBZ-UNV 17W T8'- 300QK 2 MT CEILING 2 FT. FLUORESCENT WRAP C�. -- 1i,l.I.AI S _ _.. ,.. 75<4-LI=U* I F3Q 83I -EI C * # - , 2 Q 30RCIIC ..,- ,,- A .: -1.ZQ - - .P�IIL}TI - , ,. LE ,STE3 P ; i GtT1 3,__,,- DI INTENSE lML6Ll309-C7SFW-ILC6-L2. 12\tl!'LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT - NOTES 1,3 D2 INTENSE IML6L2309-C-SFW-ILC6-L2 17W LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT- NOTES 1.3 D3 INTENSE IML61L3309-CISFW-ILC6-L3 26W LED - 3000K N/A 120 RECESSED 6"DOWNLIGHT'- NOTES 1,3 D6 INTENSE IML6L3.309-C-SFW-ILC67.2-Dl0 12W LEE-? - 3000K N/A 120 RECESSED 6" DOWNLIGHT - NOTES 13' D7 INTENSE IML6L2309-C-SFW-ILC6-L2-D10 17W LED - 3000K NfA 120 RECESSED 6" DOWNLIGHT - NOTES 1,3 D8 INTENSE IML6L3309-C-SFW-ILC6-L3-D10 26W LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT - NOTES 1,3 D9 INTENSE IML6L4309-C-5FW-ILC6- t4-Dl.G 38W LED - 3000K N/A 120 RECESSED 6" DOWNLIGHT - MOTES 1,3 E -E.IE1I4 - .. - 1 _ __ S1- ... - 711Mf16 , 2,--- .:=1T} _ ,i74fAI T IAT1` CIFE#13TEA EP+ TI#T , F1 INTENSE IL- RTR-AIC-L1309D10V-16 j RTRD300-C-SFW :14W LED - 3000K N/A 120 RECESSED 4" DOWNLIGHT- IC RATED I ., t4 ., .. 41C _. R L ..., R � 5-.p WL kT', OT9 E ,1 G PORTFOLIO L138A-60-A- DE010- E R 8A60-9- 308LM1-H 77W LED - 3000K NA 120 RECESSED 8" DOWNLIGHT - DOTES 1, 3 H NTECISE ; K4;"(CE�9WW {LI=1 51 PARZCILECI - 7t? BLESSED 4 13C)1A(iL1GFi= I110TE 4 K DAY-BRITE WTN-24W-L-U-FWT-WT 24W 4100K LEI) N/A 120 WALL 10' A.F.G. LED WALLPACK L INTENSE S56G21100308 16W LED - 30001( N/A 120 RECESSED SHOWER LIGHT - NOTE 1. M WILLIAMS 50G-S24-332-S-A12125-EBZ-UNV 32WT8- 3000K 2 MT RECESSED 2x4 FLUOR. TROFFER 6S43Ck! C�SE1iV 0 . `�I/ j €Q,> 4." fl IV: I R TR F T -I�1 ,LT L GHT E. Q i <QTE O P' Q R LITON LHLD2-LRLD219-Ulf-04A 4W LED - 3000K N/A 120 _ RECESSED _ 2' DOWNLIGHT - NOTE 1 51 LITHONIA RV8730-25-R087AR-120-TRW 34W LEI} - 3000K NA 120 RECESSED 8" DOWNLIGHT RETROFIT - NOTE 9 S2 LITHONIA RV8-30-30-1108-AR-120-TRW 42W LED - 3000K NA 120 RECESSED 8" DOWNLIGHT RETROFIT - NOTE 9 S3 LITHONIA RV8-30-30- R 08-AR-120- TRW/RG8RGINIFB 42W LED - 3000K NA 120, RECESSED 8" DOWNUGHT T LITHONIA RV6-30-15-1106-AR-120-TRW 23W LED - 3000K N'A 120 RECESSED 6"' DOWNLIGHT RETROFIT - NOTE 9 U _ NO USED _ V NOT USED W IMPACT LIGHTING IL-TG-UB-WW-3000K-12V-P FME-SA-LR-I-WW-FI= FME-SA-LR-2-WW-FF LED 1:5W/LF NA 12 COVE LED COVE LIGHTING - MOTE 6 EXIT SIGN - SINGLE FACE X1 BEGHELLI LED N/A 120 CEILING X2 BEGHELLI LED N/A 120 WALL EXIT SIGN -DOABLE FACE GENERAL NOTES: (�1 ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. Q EXHAUST HOOD LIGHTS SUPPLIED WITH HOOD AND INSTALLED BY ELECTRICAL CONTRACTOR. �3 REFER TO THE SPECIFICATIONS FOR DATA NOT ON THE DRAWINGS. (A)THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE- EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIIAENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATIONS DIRECTLY UPON CONTRACTOR. (3) SEPARATE GREEN GROUND CONDUCTOR SHALL BE ROUTED IN ALL CONDUITS WITH ALL PHASE CONDUCTORS. ©ALL MECHANICAL EQUIPMENT SHALL BE COMPLETELY CONNECTED BY ELECTRICAL CONTRACTOR INCLUDING BOTH POWER AND CONTROL WIRING. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL. DRAWINGS AND SPECIFICATIONS FOR THE REQUIREMENTS ASSOCIATED WITH WIRING AND CONNECTION OF INTERLOCKING AND CONTROLS OF MECHANICAL UNITS AND THERMOSTAT LOCATIONS. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS FOR CLARITY ONLY, ELECTRICAL CONTRACTOR MAY GROUP SINGLE POLE BRANCH CIRCUITS IN MULTIPLE CIRCUITS HOME RUNS. (3 CIRCUITS MAX @ 120/208V 30, 2 CIRCUITS MAX @ 120/24OV. 30 & 10). A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL POWER, RECEPTACLE, AND LIGHTING CONDUITS. ®ALL EXTERIOR CONDUIT FOR ROOF MOUNTED EQUIPMENT AND WIRING SHALL BE MINIMIZED BY ROUTING IN CEILING SPACE. NO EXTERIOR CONDUIT WILL BE ACCEPTED. QQ ALL CONDUITS SHALL BE CONCEALED IN WALL SPACE, CEILING SPACE OR UNDER FLOOR, NO EXPOSED CONDUITS PERMITTED. ® COMPLETE SYSTEM SHALL BE GROUNDED PER N.E.0 ARTICLE 250. FINAL CONECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITH U.L. APPROVED LIQUIDTIGHT CONDUIT. PROVIDE WITH GROUND WIRE SIZED PER N.E.C. ARTICLE_ 250 (2008). ® E.C. SHALL PROVIDE AND INSTALL ELECTRICAL DEVICES AND WIRING TO COMPLY WITH N.F.P.A. 96.7-3.1.3 FOR POWER SHUTOFF ON ALL ELECTRICAL EQUIPMENT UNDER OVEN HOOD VERIFY INSTALLATION AND OPERATION REQUIREMENTS WITH EXTINGUISHING SYSTEM SUPPLIER. PROVIDE POWER IF REQUIRED BY LOCAL CODE. ©ALL BRANCH CIRCUIT WIRE SIZE SHALL BE MINIMUM #12 AWG COPPER. PULL EQUIPMENT GROUND IN ALL RACEWAYS, PER N.E.C. . ELECTRICAL CONTRACTOR SHALL PROVIDE PROPER NUMBER AND SIZE CONDUCTOR PER N.E.C.. ELECTRICAL CONTRACTOR SHALL PROVIDE AT EACH PANELBOARD -A -TYPED CIRCUIT DIRECTORY WITH PROTECTIVE PLASTIC SLEEVE. ® FIELD COORDINATE ALL LIGHTING SWITCH LOCATIONS WITH OWNER AND INTERIOR DESIGNER. ELECTRICAL LEGEND RECESSED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC: CONDUIT CONNECTION. UPPER CASE LETTER INDICATES FIXTURE TYPE, TYPICAL FOR ALL LIGHTING FIXTURES. ® RECESSED LIGHTING FIXTURE, SAME AS ABOVE EXCEPT WITH EMERGENCY — — — BALLAST. ® FLUORESCENT LIGHTING FIXTURE - SURFACE OR PENDANT MOUNTED. STRIP FLUORESCENT LIGHTING FIXTURE. (O PL FLUORESCENT, LED, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - RECESSED. ® PL FLUORESCENT, LED, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - SAME AS ABOVE 00-1 PL FLUORESCENT, H.I.D. OR INCANDESCENT LIGHTING FIXTURE - SURFACE OR ALL MOUNTED. ENDANT MOUNTED LIGHTING FIXTURE. Y PL FLUORESCENT, INCANDESCENT OR H.I.D. LIGHTING FIXTURE - FLOOD LIGHT. PENDANT MOUNTED PADDLE: FAN COMPLETE WITH PENDANT &CEILING MOUNTED CANOPY -MOUNT AS DIRECTED BY INTERIOR DESIGNER ARCHITECT U.N.O. / 4) EXIT LIGHT - PROVIDE ARROWS AS INDICATED, SHADING DENOTES FACE OPERATION. -- DO NOT SWITCH. EMERGENCY LIGHTING FIXTURE. DO NOT SWITCH. TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL12211 WITH NO. P1 COVERPLATE - 46 MOUNTING HEIGHT, U.N.O. $2 TOGGLE SWITCH - TWO POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL12221 WITH NO. P1 COVERPLATE - 46" MOUNTING HEIGHT, U.N.O. $M TOGGLE SWITCH - SINGLE POLE, 20 AMP, 120/277V, MOTOR RATED, GROUNDING TYPE, MOUNT AT EQUIPMEENT HOUSING. $s TOGGLE SWITCH - THREE-WAY QUIET TYPE, 20 AMP, 120/277 VOLT, HUBBELL 1 NO. HBL12231 WITH NO. P1 COVERPLATE, 46" MOUNTING HHEIGHT, U.N.O. $D DIMMER SWITCH - LUTRON NOVA SERIES, 2000 WATTS, SELECT FOR r' LOAD/BALLAST/DRIVER TYPE. 46" MOUNTING HEIGHT, U.N.O. $F FAN SPEED CONTROL SWITCH - LUTRON NFS-12E, 12 AMPS. 46" MOUNTING HEIGHT, 1 U.N.O. ® OCCUPANCY SENSOR WALL SWITCH - WATTSTOPPER #DW-100-1. 46" MOUNTING HEIGHT, U.N.O. QM CEILING MOUNTED LOW VOLTAGE MOTION SENSOR-WATTSTOPPER DT-305. PROVIDE POWER PACKS AS REQUIRED. 19 WALL MOUNTED OCCUPANCY SENSOR -WATTSTOPPER DT-205. MOUNTED W AT 10' A.F.F. PROVIDE POWER PACKS AS REQUIRED. DUPLEX RECEPTACLE - 20 AMP, 120 VOLT, Z, WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P8 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O. DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 42" MOUNTING HEIGHT, U.N.O. DOUBLE DUPLEX RECEPTACLES - (2) TWO 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO, P82 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O. DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, 3 WIRE GROUNDING. HUBBELL NO. GFTR201 WITH NO. NPJ261 COVERPLATE, 46" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18" A. F. F. ® SAME AS ABOVE EXCEPT FLOOR MOUNTED IN TOMBSTONE DOUBLE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, 3 WIRE GROUNDING. (2) HUBBELL NO. GFTR201 WITH NO. NPJ2621 COVERPLATE, 46" MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18" A.F.F. ® SPECIAL PURPOSE RECEPTACLE COMPLETE WITH COVERPLATE. SEE FLOOR PLAN FOR COMPLETE CONFIGURATION. DATA/TELEPHONE OUTLET - 4 INCH SQUARE JUNCTION BOX WITH 1-GANG EXTENSION RING, BLANK COVERPLATE - 18" MOUNTING HEIGHT, U.N.O. PROVIDE 1" CONDUIT TO ACCESSIBLE CEILING SPACE. C� 360 40 rm U.N.O. AFF AC C GG E.C. m- RR O FAC P FAAP QJ JUNCTION BOX SIZE PER NEC. EXISTING TELEPHONE DATA OUTLET TV OUTLET - 4 INCH SQUARE JUNCTION BOX WITH 1-GANG EM EXTENSION RING AND BLANK COVER PLATE - 18" MOUNTING HEIGHT, U.N.O. INSTALL 1 " C. TO CEILING SPACE. FLUSH MOUNTED FLOOR BOX WITH (1) DUPLEX RECEPTACLE, (1) DATA PLATE, AND (1) AV PLATE. H WIREMOLD TYPE EF66S WITH EFB61 OCTBK COVER. INSTALL (1) lY4" CONDUIT WITH PULLSTRING FROM AV lolvi LOCATION TO CEILING, (1) 1Y4" CONDUIT WITH PULLSTRING FROM TEL/DATA LOCATION TO CEILING, AND (1) %"' CONDUIT WITH POWER CABLES FOR POWER. MOTOR, FAN, PUMP OR AIR CONDITIONING UNIT CONNECTION PER NEC. LIGHTING AND/OR POWER PANELBOARD. WIRING IN CONDUIT, RUN CONCEALED IN SLAB OR UNDERGROUND. WIRING IN CONDUIT, RUN CONCEALED ABOVE CEILING OR IN WALLS. HOMERUN TO PANELBOARD - NUMBER OF ARROWS DENOTES QUANTITY OF CIRCUITS. CROSSMARKS INDICATE QUANTITY OF NO. 12 CONDUCTORS. RUNS VOID OF CROSSMARKS ARE 1/2 INCH CONDUIT, 3 NO. 12, U.N.O. DO NOT COMBINE HOMERUNS EXCEPT AS SPECIFICALLY INDICATED ON THE PLAN. DISCONNECT SWITCH, "3 60/40" DENOTES 3 POLE, 60 AMP, 40 AMP FUSES. DENOTES WEATHERPROOF WHILE -IN -USE - MOUNT RECEPTACLE VERTICALLY AND PROVIDE TAYMAC 71202 COVERPLATE, FOR SWITCHES PROVIDE TAYMAC 40110 COVERPLATE. UNLESS NOTED OTHERWISE. ABOVE FINISHED FLOOR. DENOTES MOUNTED ABOVE COUNTER HEIGHT. DENOTES MOUNTED RECCESSED IN CEILING SOFFIT. GREEN GROUND CONDUCTOR. EMPTY CONDUIT WITH PULL WIRE/CORD. IN -GROUND COMPOSITE HAND HOLE WITH TRAFFIC !FATED COVER. SIZE AS REQUIRED BY CODE CEILING MOUNTED J-BOX WITH BLANK COVER PLATE FOR CAMERA. INSTALL 3/4" CONDUIT WITH PULLSTRING TO ACCESSIBLE CEILING LOCATION. SEMI -FLUSH MOUNTED MANUAL FIRE ALARM PULL STATION, 46 INCH MOUNTING HEIGHT. SEMI -FLUSH MOUNTED FIRE ALARM AUDIO/VISUAL WARNING DEVICE, 80 INCH MOUNTING HEIGHT FROM FLOOR TO BOTTOM OF DEVICE. DUCT MOUNTED SMOKE DETECTOR, MOUNTED IN A/C; DUCT. SEE MECHANICAL DRAWING FOR MOUNTING LOCATION AND QUANTITY. AIR CONDITIONING/HEAT PUMP SHUT -DOWN RELAY. CEILING MOUNTED SMOKE DETECTOR. CEILING MOUNTED HEAT DETECTOR. FIRE ALARM CONTROL PANEL FIRE ALARM ANNUCIATOR PANEL M im DATE:q- NFFER 14N4�'}.r] tjJNO OROOP,LLC 1 . • da:lwpr+�16��227► n aer.e.wm /�/ Ts�12 ' )239J623 V_ . <_.-_ ._.__.__..___ id of 9: 26265 __ » 4. ; .J.BR IS PE #58168 71, 5E ILL I S A1. s9OrZ, �'t 01I - - - ARE SUBJECT TO ANY CO MEC TION ,. �� R>ia�lJl�i�1� BY FIELD 4N�'EC7GRr I � ,6 sT PAY RE 14ECESSAOIY IN ()RDL�R `I" � � .� F '�41`: "'s1➢pia F`. °.� iI ! �'aa'rk° �� I„ L3Lyt, �,,�.�A • O RQq\;,. Aof >- V) m m z 0 a z of o � 0 V) o V) � W Q o o � o az THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. Ela PRE-ENGINEERED TRUSS PER PLAN CONT HSS6x2xv4 SEE 6/S2.2 FOR CONN TO ROOF TRUSS 6" 18 GA WALL STUDS @ 12" OC TRUSS BRG EL PER PLAN CONT 18 GA TRACK W/ (2)-#12 SCREWS @ EA STUD & 0.145" 0 PAF @ 4" OC INTO STL TUBE SIMPSON SPH @ 16" OC WALL SHEATHING ROOF SHEATHING PER PLAN SIMPSON LRU28 W/ (6)-10dx1Y" NAILS INTO RIDGE BEAM & (5)-I0d NAILS INTO 2x FRAMING (TYP) ivv�a.: �a:ruvl PER PLAN 1SECTION- SECTION- V_ 52.3 I SCALE: NTS S?•3 SCALE: NTS 5 "CB— j I1 ELEVATION SITSCALE: NTS j 2x BLOCKING @ 24" OC TRUSS BRG EL PER PLAN _..... _ ROOF TRUSS PER PLAN (TYP) WALL FINISH---/ PER ARCH (TYP) 9SECTION- S2.3 SCALE: NTS T/ CONC BEAM EL PER PLAN "CB-2" PER 13/S2.3 2x6 BETWEEN TRUSSES W/ y"Ox2Y4" TAPCON SCREWS @ 8" OC STAGGERED (TYP) WALL REINF PER GENERAL NOTES #3 TIES @ 8" OC (TYP) #5 EF (TYP) VARCHED BEAM 'ER ARCH ROOF TRUSS PER PLAN INFILL PER ARCH TRUSS BRG EL I PER PLAN a M M 1? SIMPSON HU210 WHERE TRUSS HAS A MAX REACTION OF 2000# AND MAX UPLIFT OF 500#. COORD W/ TRUSS SHOP DWGS. CONTACT FOR CONNECTION WHERE LOADS ARE HIGHER THAN SHOWN. 10 52.3 SCALE: N'! TA. SCALE: NTS k�:7 T/ CONC BEAM EL ivPER PLAN 2x6 BETWEEN TRUSSES W/ Y4"Ox2Y4" TAPCON SCREWS @ 8" OC STAGGERED (TYP) "CB-2„ PER INS2.3 WALL REINF PER GENERAL NOTES WALL FINISH PER ARCH (TYP) NOTE: SEE 9/S2.3 FOR INFO NOT SHOWN. FRAMING ?,PLAN IT) CLIP, PER FASTENER SCHEDULE ROOF TRUSS PER PLAN (TYP) CONT 2x_\ PER ARCH B/ TRUSS EL PER ARCH PROVIDE Y"O THRU i BOLT THRU BEAM & \ BRACKET. SEE 12/S2.3 FOR BRACKET- DETAIL & ATTACHMENT TOSTRUC r(' ' 11 " S2.3 SCALE: NTS T/ CMU WALL PER PLAN CONT 16" BOND BEAM W/ #5 CONT TOP & BOTT WALL FINISH PER ARCH PROVIDE ADDITIONAL REINF PER PLAN @ BRACKET ATTACHMENT ROOF SHEATHING PER PLAN (TYP) HSS4x3xY4 (LDV) (TYP) STL BEAM PER PLAN (TYP) 0 2x6 BETWEEN TRUSSES W/Y"0x2Y4" TAPCON SCREWS @ 8" OC STACTCTF.RF.1) (TYP) TRUSS BRG EL . _. PER PLAN SIMPSON RU210 WHERE TRUSS HAS A MAX REACTION OF 2000# AND MAX UPLIFT OF 500#. COORD W/ TRUSS SHOP DWGS. CONTACT FOR CONNECTION WHERE LOADS ARE HIGHER THAN SHOWN. WALL REINF PER GENERAL NOTES CMU WALL PER PLAN #4 @ 32" OC �NX pl 7 F L �® S2.3 SCALE: NTS 4'-0" "1I X"O THRU BOLT THRU BEAM & BRACE ROOF SHEATHING 2x BLOCKING PER PLAN BETWEEN 2x FRAMING (TYP) CONT 2x10 w/(3)-10d NAILS @ 8" OC, STAGGERED. SLOPE 2x TO MATCH ROOF SLOPE (TYP) PRE-ENGINEERED ROOF TRUSS PER PLAN EXIST CMU WALL EXIST CONIC BEAM #4 DOWEL (TYP) NEW CMU WALL EXIST SLAB EXIST FDN ■ X"O LAG SCREW —� 14]Y2" W/ 3" MIN EMBED INTO VERT MEMBER PT 4A (TYP) °1) WO THRU BOLTS (TYP) WO EPDXY ANCHOR INTO CMU WALL W/ 6" MIN EMBED (TYP) SLAB EL FINISH PER ARCH 4 , T ON 52.3 SCALE: NTS BEAR 2x FRAMING ON ROOF TRUSS �— 2x FRAMING PER PLAN. SIMPSON H4 @ EA 2x (TYP) GIRDER TRUSS @ 2x FRAMING SIMPSON RSP4 @ 32"OC (T&B) CONT 2x 10 w/ 11"0 THRU BOLTS @ 12"OC STAGGERED. RIP 2x10 TO MATCH BEAM WIDTH. STEEL BEAM PER PLAN ROOF SHEATHING 1 PER PLAN (TYP) INFILL PER ARCH EXISTING ROOF TO REMAIN `— PRE-ENGINEERED ROOF TRUSS ATTACH TRUSS TO CONC WALL W/ SIMPSON HU28 PER PLAN W/ (6)-XXIY4TITEN SCREWS INTO CONC & (4)-1Odx1Y NAILS CONT 2x W/ SIMPSON INTO TRUSS. H3 @ EA TRUSS NOTE: PROVIDE HU28 Q W/ 45° SKEW AS REQ'D. w w 2A STUDS @ 24" OC EXISTING WALL TO REMAIN f CONT 2x W/ Y"O TAPCON SCREWS @ SECTION16" OC INTO CMU S2. SCALE: NTS A THESE PLANS AND ALL t C?OaEl3 WORK ARE SUBJECT TO ANY CORRECTIONS REOUIRID BY PIELD INSPECTORS THAT L6x4xX,)x4" LONG (LLH) MAY BE NECESSARY lld OM R TO W/ (I)-Y,"O THRU BOLT COMPLY WITH, ALL APPLICAD LE CODES. @ BRACE & (I)-Y4'O EPDXY ANCHOR INTO WALL 811 W/ 6" MIN EMBED #3 TIES @ 12" OC I (2)-#6 CONT TOP, MID & BOTT a �3 T I' 11C -�" AIL S2.3 SCALE: NTS WALL REINF PER GENERAL NOTES — CMU WALL PER PLAN LOWE STRUCTURES, INC. 4337 Pablo Oaks Ct., Suite 101 Jacksonville, FL 32224 (904)992-0377 FL Cert of Auth: 28261 EOR: J. Matthew Lowe FL PE: 59027 m O Z o N w W 0 O Zof O O 0 W O O 0 W o N N o rn 6 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP. AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. t w al i �j PLANNING —ARCHITECTURE-LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 PRE-ENGINEERED TRUSS PER PLAN ROOF SHEATHING PER PLAN CONT 2x 1 PER ARCH GC TO PROVIDE VAPOR BARRIER UNDER TRUSSES (TYP) TRUSS BRG EL PER PLAN CLIP, PER FASTENER SCHEDULE \ `-CONT 16" BOND BEAM W/ 245 TOP & BOTT \`- WALL REINF PER GEN NOTES �- CMU WALL PER ARCH SEC 52.2 SCALE: NTS ROOF SHEATHING PER PLAN CLIP, PER FASTENER SCHEDULE PRE-ENGINEERED TRUSS--------., PER PLANI / PRE-ENGINEERED TRUSS BEYOND CONT HSS6x2xY SEE 6/S2.2 FOR CONN TO ROOF TRUSS 6 16 GA WALL STUDS @ 12" OC - CONT 2x PER ARCH CONT 2x FOR ROOF SHEATHING ATTACHMENT. ATTACH TO EA TRUSS W/ (2)-IOd NAILS ROOF SHEATHING PER PLAN /- BLOCKING TRUSS BETWEEN / LOW TRUSSES FOR HIGH TRUSS BEATING. ATTACH TO WALL BELOW W/ SIMPSON CS 18* FA FACE, EA END OF BLOCKING. TRUSS BRG EL PER PLAN �- CONT 16 GA TRACK W/ (2)-#12 SCREWS @ EA STUD & 0.145"0 PAF @ 4" OC INTO \ STL TUBE \l _ SIMPSON SPH \ @ EA STUD - `- WALL SHEATHING NOTES: 1) CONTACT FOR FOR ALTERNATE DETAIL IF ROOF TRUSS IS CONT. OVER WALL. 2) "*" DENOTES PROVIDE (3)-#10 SCREWS (MIN) INTO EA WALL STUD & (8)-10d NAILS (MIN) INTO BLOCKING TRUSS. STOP ROOF TRUSS 4" SHORT OF EXIST WALL @ SIM. ROOF SHEATHING PER PLAN TRUSS BRG EL PER PLAN ROOF TRUSS PER PLAN 5 SECTION 52.2 SCALE: NTS EXISTING ROOF STRUCTURE TO REMAIN 4" SIM CONT 2x W/ A"O -� TAPCON SCREWS @ 16" OC INTO CMU r 10 SECTION- S22 SCALE: NTS ROOF SHEATHING PER PLAN PRE-ENGINEERED TRUSS PER PLAN CLIP, PER FASTENER SCHEDULE ,; S2. SCALE: NTS PRE-ENGINEERED TRUSS PER PLAN CONT DBL 2x PL W/ A"O THRU BOLTS @ 12" OC, STAGGERED STL BEAM PER PLAN WEN - TRUSS BRG EL PER PLAN y" STL TAB EA SIDE iI ( I CONT 18 GA TRACK OF EA TRUSS. SEE I 1 W/ (2)-#12 SCREWS CEILING DETAIL A -A. @ EA STUD & 0.145"0 PER ARCH TYP /J PAF @ 4" OC INTO STL TUBE CONT HSS6x2x1/4--/ I I SIMPSON SPH I @ EA STUD 6" 18 GA WALL I I STUDS @ 16" OC, - WALL SHEATHING UNO ON PLAN. 6 SEC ON S2 2 SCALE: NTS - 2x6 BETWEEN TRUSSES W/Y"0x2Y" TAPCON SCREWS @ 8" OC STAGGERED (TYP) (CONT 2x6 @ SIM - ATTACH TRUSS TO CONC WALL W/ SIMPSON HU28 W/ (6) Y Y4 TITEN SCREWS INTO CONC & (4)-1 OdxIY NAILS INTO TRUSS. -CONT 2x W/ SIMPSON H3 @ EA TRUSS. (SIMPSON HGAMIOKT @ SIM) - WALL SHEATHING BY OTHERS -2x4 STUDS @ 24" OC - EXISTING WALL TO REMAIN NOTE: PROVIDE HU28 W/ 45° SKEW AS REQ'D. EXISTING ROOF STRUCTURE TO REMAIN ATTACH 2x TO CONC fl WALL W/ SIMPSON HU28 W/ (6)Yx1Y TITEN SCREWS' INTO CONC & (4)-1OdxUz NAILS INTO 2x. ROOF SHEATHING PER PLAN ` JOIST BRG EL 11 F-4 d" Q 2x FRAMING PER PLAN `L CONT 2x W/ A"O J TAPCON SCREWS @ 16" OC INTO CMU 4" MIN II S I S2. SCALE: NTS WHERE UPLIFT <800# TRUSS BRG EL PER PLAN EDGE OF ROOF TRUSS A" STL PL EA SIDE OF TRUSS WO THRU BOLT CONT HSS6x2xY EDGE OF ROOF TRUSS A" STL PL EA SIDE OF TRUSS Y" 0 THRU BOLT (TYP) CONT HSS6x2xA WHERE UPLIFT <1600# NOTE: COORD TRUSS UPLIFT & LOCATION W/ TRUSS SHOP DWGS. DETAIL A -A ROOF SHEATHING PER PLAN GC TO PROVIDE VAPOR-� BARRIER UNDER TRUSSES (TYP) 2" (TYP) NOTE: ROOF TRUSS CONTINUOUS OVER WALL @ SIM. SE(2_7I 52.2 SCALE: NTS HSS4x3 2-2x8 PER PLAN 2x8 EA SIDE (TYP) OF TUBE f.. SIMPSON 2X" TB ATTACH 2-2x8 TO BEAM SCREWS @ 6" OC W/ SIMPSON A23 STAGGERED (Typ) (TYP) r7 SECTION S2.2 SCALE: NTS PRE-ENGINEERED TRUSS PER PLAN TRUSS BRG EL PER PLAN CLIP, PER FASTENER SCHEDULE (TYP) CONT 16" BOND BEAM W/ 245 TOP & BOTT WALL REINF PER GEN NOTES CMU WALL PER ARCH 2x BLOCKING BETWEEN TRUSSES FOR SHEATHING ATTACHMENT ROOF SHEATHING PER PLAN CONT SHEARWALL SHEATHING UP TO ROOF SHEATHING PRE-ENGINEERED TRUSSJ I PER PLAN I CONT HSS6x2xA I SEE 6/S2.2 FOR CONN TO ROOF TRUSS ' f I 6" 18 GA WALL f STUDS @ 16" OC, UNO ON PLAN. - �✓ SECTS S22 SCALE: NTS STL TUBE CLIP, PER FASTENER BEYOND SCHEDULE (TYP) r � CONT DBL 2x TOP PL 2x FRAMING PER PLAN SIMPSON RSP4 @ 32" OC I I CONT 2x SILL PL W/ #8 SCREWS @ 8" OC, STAGGERED CONT 2x I W/ SIMPSON 2%" TB SCREWS @ 6" OC STAGGERED _. FINISH STL TUBE PER ARCH PER PLAN TRUSS BRG EL PER PLAN TRUSS SUPPLIER TO �- CONT 18 GA TRACK CANTILEVER THIS SECTION. W/ (2)-#12 SCREWS @ EA STUD & 0.145"0 PAF @ 4" OC INTO o STL TUBE \--SIMPSON SPH @ EA STUD 1 \-- WALL SHEATHING ASSEMBLY PER CONT 2x w/(3)- IOd NAILS DETAIL 9/S2.2 ROOF SHEATHING @ EA STUD (TYP) PER PLAN RIDGE BEAM PER PLAN (TYP) T/BEAM EL SIMPSON RSP4 - PER PLAN @ 32" OC 9pp _ FINISH ROOF SHEATHING ROOF SHEATHING PER ARCH PER PLAN PER PLAN 2x FRAMING SEE DETAIL 4/S2.2 PER PLAN FOR INFO NOT SHOWN SIMPSON H3 STEEL BM @ EA 2x PER PLAN CONT L4x4x>$ w/ WOOD BEAM CONT 2x A 0 THRU BOLTS TYP PER PLAN (TYP) @ 16"OC. 3/16 2@6 _. S2.2 SCALE: NTS SEE ARCH ROOF SHEATHING PER PLAN HSS4x3 BRACE (SIM) PER 6/S2.3 STL TUBE PER PLAN TYP 3/16V 3 ()I IO PL A"A"W' EA SIDE OF BEAM W/ (2)-A"O THRU BOLTS (TYP) 9 SECTIO S22 SCALE: NTS RIDGE BEAM PER PLAN T/BEAM EL O PER PLAN I I CONT 2x - L' PER ARCH COPE BEAM AS REQ'D PER ARCH SIMPSON H10A Typ HSS4x3 BRACE PER 6/S2.3 PAD BEAM AS REQ'D (TYP) SEE DETAIL 9/S2.2 CONT 2x FOR INFO NOT SHOWN ASSEMBLY PER PER ARCH SEE DETAIL 4/S2.2 CONT 2x w/(3)- lOd NAILS DETAIL 9/S2.2 FOR INFO NOT SHOWN @ EA STUD (TYP) RIDGE BEAM 13 E C TI r . . PER PLAN (TYP) 2x6 BETWEEN TRUSSES W/A"Ox2Y" TAPCON ROOF SHEATHING S2.2 SCALE: NTS SCREWS @ 8" OC PER PLAN TBEAM EL STAGGERED (TYP) PER PLAN G O SEE ARCH ROOF SHEATHING 2x8 OUTRIGGER 2x FRAMING CONT 2x W/ SIMPSON TBEAM EL - PER PLAN HSS4x3 BRACE @ 24"OC w/SIMPSON PER PLAN .. H3 @ EA TRUSS - FINISH (SIM) PER 6/S2.3 A35 (TYP) PER PLAN TBEAM EL • ATTACH RIDGE PER ARCH PER PLAN THEE PLANS A ALL R-10PO offs WORK 2x4 STUDS 24" OC # : BEAM TO CONT 2x W/ SIMPSON HU28-2 CONT 2x ARE SL'dECT TO ANY C0MlRECF!€NS WALL SHEATHING CONT 2x whk x 2 $TITEN PER ARCH COPE 2x AS f`ttl1ll7 BY FIELD I�5F6CT�JS THAT BY OTHERS 2x FRAMING SCREWS @ 6" OC. STAGGERED (2)-SIMPSON H5 @ REQ D PER ARCH EA OUTRIGGER TYP HSS4x3 BRACE PAY BE NECLSSANY IN A TO „ WiIS�1� ! V11TH All AMICABLE CODES. EXISTING WALL PER PLAN CB-1 PER 6/S2.3 r � � � TO REMAIN PER 5/S2.3 PAD BEAM SIMPSON I U210 @ EA 2x w/(9)-1/4x 1 AS REQ'D (TYP) SEE DETAIL 7/52.2 TITEN SCREWS INTO CONC. SEE DETAIL 4/S2.2 CONT 2x FOR INFO NOT SHOWN I (4)-IOdx1 1/2 NAILS INTO 2x (TYP) FOR INFO NOT SHOWN PER ARCH LOWE STRUCTURES, INC. 4337 Pablo Oaks Ct., Suite 101 Jacksonville, FL 32224 �s TI � y� G j % (904) 992-0377 12 C � % — FL Cert of Auth: 28261 52.2 SCALE: NTS S2.2 SCALE: NTS EOR: J. Matthew Lowe FL PE: 59027 \1--0001 R m Z p O O ~ (nn H � w o � � O w O 0 � N rq � N O ~ 0 z ~ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH T IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. t i i • M i 4 �L i 1 PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.:,..AA2f000586 a ®3� ® AI E-/�Ogf 1 � a DRAWN BY TJM CHECKED BY .1ML DATE 3-26-14 JOB NO. 13-40 SHEET NO. S292 I : f ` - - .L - I If -. i ;� -\ ® ® J �® ��I� O O G O O O ti r 0_ 1O �0 Z- 10 �O �O L4 LA I I fr �O O1 T I �_ .: __ f' -gyp -�® -gyp -'p " r r �9 _°,a, ® J�, �, 4 I r c.�.� i I C, 77 1 1 1 1 t�� . y ® �1�®�,;� —�7-� Op �� L—J I!: II II II II r vz - ----r-id_ r_ i" I 0 4 il� LJ LJ ,;-p op op o®. 1® C p < ' o®�® o } g - p p p II II II II II II II II iV ��IT7Op - -- -� o 0 1+ 1+ I o� Y ®Y� 11:_j CrJC t_ b �p 4 ® -y 'y10 ��� p� I - � I �, I p iI C � C 3 C +T® p +T® ��� I /` L J' I® U© U© U©' 9 O I i - , 1® ® -, �- 0 J� i ®O ��:. �- ,err o oO a ,! IL 9O11 O j II II II II . g ; �+ �+ o ® ® - - Q C�J�rJ� �J�rJ��J�O 4 �; L J L J _ o j �- — _1 III it r,9 r� �r� 'I �I o o ®j y - i E --y % a� �9`9'-- p'�p , L L <.: `. �- o p gp g9 I p- ,:; 4 4 i j; ©® <� i -� a® a® r ® r �o � t � �� _ I � (D ® ' �I� lO O' tIi �� '� 1 1 1 1 1 1 1 1 I ti �r �I i L , .� I r- �� y._, c�j p f ; I 1(I j L !L_ JL _ _—! r =11p y� O I_� = s� 4 I i __ ® ( - - - �, (0) -- r LJ1 �. - f '1�111 r r �9 __ ( �9 �/ Cod i : ® /l >} t 1 1 1 YYY C� -- ® ® - u N ELECTRICAL_ DEMO PLAN-L GHT NG 1 SCALE: 1 /8"= 1'-0" I I ® ® e % ` NOTES: U U ® REFERENCE NOTE ON DRAWING I ! I 1. EXISTING LIGHTING FIXTURES, CIRCUITING AND '_` ' CONTROLS TO REMAIN. DEMOLITION NOTES: I- - p © - ---_- t n n ; n C (z) C �_ �, �,�� j C ® 2. EXISTING LIGHTING FIXTURES TO BE REMOVED. 1 SCHEDULISHALL OFNOT SUCH 0 TAGESINTERRUPTION WTH THETOWNSERVICES ER'S REPRESENTATIVETING BUILDINGS WITHOUT PRIOR rr 1 O pi I U 3. EXISTING DEVICE TO BE REMOVED. U U ® _a 2. THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN 4. EXISTING LIGHTING FIXTURE TO BE REPLACED. ASSOCIATION WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS - - OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE_ 4 1 I F •� p ® I i 5. EXISTING SWITCHING TO BE REPLACED. CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. n n \ > Q }1® Q'. 6. MAINTAIN CIRCUITS TO ALL EXISTING RTU'S, 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO I C C� j I AHU'S, AND CONDENSERS. EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS -BUILT" DRAWINGS TO THE OWNER, ' U U INDICATING ANY SUCH CHANGES. — 7. EXISTING FAN TO REMAIN. n0 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF 1 C 1� 8. EXISTING TRACK TO REMAIN. EXISTING TRACK CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS ® Q4 ®\ = 7 U HEADS TO BE REPLACED. SHALL BE CAPPED AT POINT OF CONCEALMENT. ' I 9. EXISTING CIRCUITING AND CONTROLS TO REMAIN. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING I-- -=- - CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT j ® 4 ® i � THE END OF A CIRCUIT, CONTRACTOR SHALL RE. -MOVE WIRING FROM LAST REMAINING DEVICE, FOR (0) (0) EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE" WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NI_-w WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES _ OR FIXTURES. 10 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS MEET CURRE14T CODES AND SPECIFICATIONS. REMOVE ALL UNUSED SURFACE MOUNTED f ` CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. % r 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL \` ��-� �- ---- --- - �- --- ---- ---% BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT. THESE PLANS AND ALL P4101POSEn WON ARE SUBJECT TO ANY COMECTIUNS REQUIRED BY PIELD INSPECTORS THAT MAY BE NECE96MY IN ORDER TO CO PL"If ITH A ,1- APPLICABLE CODES. ------ ------ -- - N IRI F 0, UP.LLC BRY N S"I�fE5 ENSE# 58 6� ST"_ OF r a ,� I I >_ Ln m m z 0 z o' 0 ui 0 0 I z Q z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF WHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. U a) c O~l ct -�—� Cn C U a w rm INIC 4 Q r Z.I W BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E2,0 r f /t � i l \ve ! h. EXISTING 46{ EXISTING ATT KWHM I TERMINAL BOX I LJ !) BEXISTING ,I�PL � &EXISTING—m► TRA,NSF& MER / PANEL. DPA 11 L 0 t � Ir��,-. I ` I ! ff _J , l __-- _,----- . _----- ------- .----_..--.---- \ 1Q \ _ _----r=_._ « - EXI'STINGO = - F ___ ___ _____ _ _...._ ► F I I —O ®� j _' j ��� p I FF-I p PANEL FACP #t__ tt tt tt R tt T tI; ff c\ __-------f it 0'�'! i 19 � 'tug` !! n11 r �` ilia i i ,40 Va "996" _/0 _ f L. JL j J I EXISTIPANELS KX NG; ffQ FE lc f 1? O _ z_�—� __ � ,�� 1 EXISTING 0 ELE. BOARD f n� aECISTING EXISTING -�-- ( Q 96 �r JO _� n SECURITY ''PANEL �N ° I - �`_ �I�� SERVER RACK f� 0til 1 (�- _ !96 �' I10TING - EXIST I - QEXISOUN j IDNG\\ O BAPANELS& BB j; SYSTEM k , I 1I O RG OIL�' f ( - , - r� I ® # T ID �VQ [Tv EXISTING 96 f FAAP 1 I L.J ! ., WOP '".... LFJ LFJ p }}O r Od � : — --- - --ice- -_- -- Y+ r ! � � ` { - 0 p _ ©► !f �(,' rt -. I ! I i � ELECTRICAL DEMO PLAN -POWER - ,AND SYSTEMS SCALE: 1 /8"= 1'-0" NOTES: 10 REFERENCE NOTE ON DRAWING 1. EXISTING DEVICE TO BE REMOVED. 2. EXISTING DEVICE TO REMAIN. 3. EXISTING DEVICE TO BE REPLACED. 4. EXISTING DEVICE TO BE RELOCATED 5. EXISTING PANEL TO REMAIN. 6. EXISTING PANEL TO BE REPLACED. 7. EXISTING TRANSFORMER TO BE REPLACED BY FPL IF REQUIRED DUE TO BUILDING LOAD. DEMOLITION NOTES: 1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOFf, SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. 2. THE CONTRACTOR SHALL NOT -TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN ASSOCIATION WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL 13E REMOVED FROM THE SITE. 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS -BUILT" DRAWINGS TO THE OWNER, INDICATING ANY SUCH CHANGES. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL. BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES OR FIXTURES. 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS MEET CURRENT CODES AND SPECIFICATIONS. REMOVE ALL UNUSED SURFACE MOUNTED CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NCIT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF' EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT. THESE PLANG AWL) ALL PnCjpO )Et3 W'OM ARE SJ:BJECT TO ANY CORRECTIONS REQUIRSD BY PILL® INVECTORS THAT I'ti.AY BE NECESSARY IN ORDER TO CO A LY WITCH AI,&�, A�PLICRE3LE CODES. >_ N m m z 0 0 ~ � z Of O 0 cl � W w I O I O QZ THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. � V 1 W V1 c ct J--� a Con, C-4; U Z Q 40 I� nO' . w w BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSON VILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E2*2 PARTIAL ELECTRICAL LIGHTING PLAN SCALE: 1 /8"= 1'—O" PLAN NOTES: ® REFERENCE NOTE ON DRAWING 1. PROVIDE ADDITIONAL WIRES FOR 0-10V DIMMING. 2. CONNECT EXIT SIGNS, NIGHT LIGHTS, AND EMERGENCY BALLASTS AHEAD OF ANY SWITCHING. 3. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 4. ROUTE THROUGH LIGHTING CONTACTOR. 5. PROVIDE AS PART OF GUEST PAVILLION ALTERNATE. 6. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER PACKS PRIOR TO SWITCHES. 7. CONNECT TO EXISTING ROOM LIGHTING CIRCUIT WITH (3)#12, 1 /2" C. DO NOT EXCEED 1900 WATTS ON CIRCUIT. 8. CONNECT TO COOLER/FREEZER LIGHTING. 9. EXISTING LIGHT FIXTURE TO BE REPLACED. CONNECTTO EXISTING CIRCUIT.. 10. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS UNLESS NOTED OTHERWISE. 11. INSTALL NEW LED_. RETROFIT IN EXISTING FIXTURE 12. EXISTING FAN AND CIRCUITING TO REMAIN. 13. RELOCATE AND REPLACE EXISTING LIGHTING CONTROLS WITH NEW. FIELD VERIFY REQUIREMENTS. 14. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR EXACT MOUNTING HEIGHTS. 15. AS PART OF PAVILION ALTERNATE PROVIDE MOTION SENSORS AND POWER PACKS TO CONTROL LIGHTING SIMILAR TO MEMBER BAR. SEE SHEET E3.7. 16. INSTALL LENS WITH SMOOTH SIDE DOWN IN KITCHEN AREA. 17. SEE INTERIOR DESIGN DRAWINGS FOR DIMENSIONED LOCATIONS OF RECEPTACLES AND LOW VOLTAGE BOXES. THESE taLAM AND ALL i POS.+a h WOM ARE SUBJECT TO ANY CORRECTIONS REOUIRMID BY FIELD NSPECTORS THAT PAY BE t4ECE96ANY IN ORDER TO 00NI LY WITH AIJL, APRICABLE CODES. ,, � �.` • o,t RL 32FEB- NW, ff5e0r2e g.co m''ANw-aeouF.m LLC I CE,Ppfg •�$2i��Fj6�9 239J623 j• Cerfificat 2ation M. 8265 � s J° BRYA' A NSE IC58168 • ma • ; w .. .gym C `4i O N W- %%o� m m z 0 0 0- z w o LLJ H w I 0 0 I o Qz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. iej BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JB S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E3 40 Q PARTIAL ELECTRICAL LIGHTING PLAN SCALE: 1 /8"= 1'-0'p PLAN NOTES ® REFERENCE NOTE ON DRAWING 1. PROVIDE ADDITIONAL WIRES FOR 0-10V DIMMING. 2. CONNECT EXIT SIGNS, NIGHT LIGHTS AND EMERGENCY BALLASTS AHEAD OF ANY SWITCHING. 3. CONNECT TO EXISTING AREA LIGHTING CIRCUIT WITH (3)#12, 1/2" C. DO NOT EXCEED 1900 WATTS ON CIRCUIT. 4. ROUTE THROUGH LIGHTING CONTACTOR. 5. REPLACE EXISTING LIGHT FIXTURE. 6. EXISTING LIGHTING TO REMAIN. 7. FIXTURE TO BE PROVIDED BY OTHERS AND INSTALLED BY CONTRACTOR. 8. ROUTE ALL ROOM LIGHTING CIRCUITS THROUGH POWER PACKS PRIOR TO SWITCHES. 9. INSTALL FIXTURE AT SOFFIT. SEE ARCHITECTURAL ELEVATIONS/SECTIONS. r 10. CONNECT TO LIGHTED MIRROR. 11. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR EXACT MOUNTING HEIGHT. 12. INSTALL LENS WITH SMOOTH SIDE DOWN IN KITCHEN AREA. 13. EXISTING TRACK TO REMAIN. REPLACE EXISTING TRACK LIGHTING HEADS WITH NEW WHITE 1000 LUMEN, 3000K, LED TRACK HEADS. HEADS SHALL ALTERNATE BETWEEN SPOT AND NARROW FLOOD DISTRIBUTION. 14. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS. 15. INSTALL NEW LED RETROFIT IN EXISTING FIXTURE. 16. ALL EXISTING ROOM SWITCHING TO REMAIN. ARE SUBJECT TO ANY COMECTIONS R4OUIRM BY PIED rNSMCTORS THAX MY BE MECLEJ6ANY 04 ORDER TO �� 1MP LY @A!ITH AP,r_ I,�PP I a, I� u L E COCES. pt.;, �r.INEERINO CR0UP. LLC • 12058 San Jose ""' Suite 502 • J onville, FL 32223 =it.Z2 com • 04)239-3621, FX (904) 239-3623 y_ _ T lZft."Authorization#'. 28265 'AN SHAPFER!e.E. UC-EITSIL # 58168 m m z 0 z 0 N U5 W w i 0 0 1 Qz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. lei � MR&M 1 165 - w 191 & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JB S DATE 03-26-14 JOB NO. 13-40 SHEET NO. E3 • N PARTIAL ELECTRICAL POWER - AND SYSTEMS PLAN SCALE: 1 /8"= 1'-O" NOTES: (D REFERENCE NOTE ON DRAWING 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED UNDER FLOOR, 2. EXISTING DEVICE TO REMAIN. 3. REPLACE EXISTING RECEPTACLE AND COVER PLATE. CONNECT TO EXISTING CIRCUIT. 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH (3)#12, 1/2" C. DO NOT EXCEED 8 RECEPTACLES PER CIRCUIT. 5. CUT AND PATCH EXISTING FLOOR TO INSTALL FLOOR BOX AND ASSOCIATED CONDUIT. 6. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR EXACT MOUNTING HEIGHTS. 7. PROVIDE POWER TO FIREPLACE IGNITER. 8. POWER TO HAND DRYER. COORDINATE EXACT MOUNTING HEIGHT WITH DRYER. 9. SEE INTERIOR DESIGN DRAWINGS FOR DIMENSIONED LOCATIONS OF RECEPTACLES AND LOW VOLTAGE BOXES. THESE PLANS AND ALL RIOPOSED WORK ARE SUBJECT TO ANY COEFECTIONS REQUIRaD BY PIELD INS'ECTOMS THAT ---_.-. PAY BE NECE96ANY II4 CADER TO COMPLY WITH All PIRICABLE CODES. * P• f"..i.Ilc,fac�9NonFA�FER I.090UP,LLC ;j s •a sae 2'o�w 223 haffer com • �J '1 PH((�9�0d)239-j621, FX 3 3 • _ �pfioateof on�lionll�. 66 — J. BFAW SMAFFER, .E. LIGEN 58168 : ui . q st >_ m V) m -tl*) I!1 z 0 Q z 0 N w w I 0 0 I z Q Z THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JB S DATE 03-26-14 JOB NO, 13-40 SHEET NO. E4,0 HANDHOLE FOR FIBER/TI SEE TEL./DAT/TV SINGLE DIAGRAMI. j )'m )CKE 145{ PARTIAL ELECTRICAL POWER AND SYSTEMS PLAN SCALE: 1 /8"= l'—O" NOTES: ® REFERENCE NOTE ON DRAWING 1. ALL ELECTRICAL TO BAR SHALL BE ROUTED UNDER FLOOR. 2. EXISTING DEVICE TO REMAIN. 3. REPLACE EXISTING RECEPTACLE AND COVER PLATE. CONNECT TO EXISTING CIRCUIT. 4. CONNECT TO EXISTING RECEPTACLE CIRCUIT WITH (3)#12, 1/2" C. DO NOT EXCEED 8 RECEPTACLES PER CIRCUIT. 5. FEED COUNTER UNDER FLOOR. CUT AND PATCH EXISTING SLAB AS REQUIRED. 6. CUT AND PATCH EXISTING FLOOR TO INSTALL FLOOR BOX AND ASSOCIATED CONDUIT. 7. ELECTRICAL TO SERVICE STATION TO BE ROUTED UNDER FLOOR. 8. PROVIDE (5) RECEPTACLES AND TV OUTLET LOCATIONS AT HEIGHTS AS INDICATED ON INTERIOR DESIGN ELEVATIONS. 9. PROVIDE POWER TO FIREPLACE IGNITER. 1 10. POWER TO HAND DRYER. COORDINATE EXACT MOUNTING HEIGHT WITH DRYER. THE04 PLANS AND ALL I OPOriEt) VV0f,,I ARE SUBJECT TO ANY COO RECTICIIINS R QUIRSD BY PIED! NSPECTORS THAT NUY BE NEC196ANY IN ORDER TO COMPLY I IT6H All 1��� P,I �r � E CODES. -� 0U;I)E�RVL QVr,QR0UP.LLc Faac�ps,fip0�igiseS, �c�3i'zz d 5g 2r Co. _ `v�`• `V."— C�,T 4� 3 9E?J_onzeti- a.?.e223 I mo- o :• L FSi O N >- m LO m m mmllllrll� z 0 O � z Of 0 LLJ Of I�--+ w w I 0 0 I F Q THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS IRESTRCTED TO THE ORIGINAL SITE FOR WHICH T IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. � U c w H cts, 1� lei BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E492 ENLARGED KITCHEN (105)_ POWER AND SYSTEMS PLAN SCALE: 1 /4"= 1'-O" :QUIREMENTS AND MOUNTING HEIGHTS WITH FINAL KITCHEN EQUIPMENT SELECTIONS. 2. CIRCUITS FOR EQUIPMENT UNDER HOOD ARE PROVIDED WITH SHUNT TRIP BREAKERS. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM SO THAT ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL CUT POWER TO EQUIPMENT UNDER HOOD. 3. ROUTE CONTROL POWER THROUGH HOOD CONTROLS AND CONNECT TO GAS SOLENOID VALVE AND SHUNT TRIP AT PANEL OF EQUIPMENT UNDER HOOD. ACTIVATION OF ANSUL FIRE SYSTEM SHALL SHUT OFF THE GAS SOLENOID AND POWER TO EQUIPMENT UNDER THE HOOD AS WELL AS ACTIVATE FIRE ALARM. 4. CONNECTED TQ DOOR_, HEATER ,AND LIGHTS._. 5. SEE ARCHITECTURAL/INTERIOR DESIGN ELEVATIONS FOR REQUIRED MOUNTING HEIGHT. ENLARGED KITCHEN (127) POWER AND SYSTEMS PLAN THESE PLANS ANU ALL Fi' OPOISED WORD ARE SUBJECT TO ANY COMECTIONS REQUiRBID BY PIELD INSPECTORS THAT rv'u%Y BE NECESSARY IN OMXR T® COMPLY WITH All APPLICABLE CODES. IAFFEB-— �I C 5140f RING CIt09P,LLC a [� 3 J J on IL a BlvwwwSuit. she z ih�9-win 1!! e '� •,• • � � • . gf:(964��l-3, %(904)2393623 *` ,�•- Ait`iutiie of thori ion#: 28265 ,t. 50AN SHAFFE , P. l�' 1 E # 58168 NOnot- 0*��sS10N.�. m m z 0 O z 0 0 cr w LL I 0 0 I O Qz THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. le� BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JB S DATE 03 -26-14 JOB NO. 13-40 SHEET NO. E4,0 m m z 0 0 � z of o CA � Ld 0 V) fy_ w w I 0 0 I z Q z HIS DRAWING IS AN INSTRUMENT OF SERVICE NO THE PROPERTY OF BASHAM DESIGN GROUP, ND SHALL REMAIN THEIR PROPERTY. THE USE F THE DRAWING IS RESTRICTED TO THE RIGINAL SITE FOR WHICH IT IS PREPARED AND UBLICATION THEREOF IS EXPRESSLY LIMITED TO UCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E4,0 #3/0 IN 1"C' TO BLDG. STEEL SWBD K4DP 2OOOA \ / MCB - 2O8�2OV -�--' NEMA 3R EXISTING UTILITY TRANSFORMER `r #3/0 IN 1"C. TO METAL WATER PIPE, EXISTING SERVICE GROUND AND BUILDING FOUNDATION RBNFORC| BAR NO LESS THAN 20 FEET LONG, 1/2 INCH MINIMUM DIAMETER. � 3/4" x 16' COPPER CLAD GROUND ROD 18' TO BE REMOVED EXISTING POWER RISER DIAGRAM_ NOT TO SCALE EXISTING POWER -RISER DIAGRAM NOTES: 80 REFERENCE NOTE ON DRAWING 1. REMOVE EXISTING GROUND -NEUTRAL BOND. RTU-1 �� RTU-2 RTU-3 AC(�[]-1 ACCU-7 �����' ����' ���_ ���� �---l~ O �---l~ O �---1 ~��O �---1 ~ O �---1 ~ O L -� / 'r T EXISTING BUILDING || | ^ ' | | ' | | ' || F------------1 F----- -----� pANEL ' ' PAN EL ' r--------1 ' � | r----- ` ^ | | ^ ` | ��1�� | ' ' | P1� | ' ' | | ' ' | |/FORk4�RLY| ' ' |/F�R�WERLY| ' '� ' | | I(FORMERLY | N| '`\ N| ' � | ' / m' | | ' '`wu'/ m� | ' PANEL ' DPA ' | ' 2(]0A 2{}0A ' | ' 1OOOA ' | ' M[.(].' | | ' ��'[{). ' | \ ��8 | ' �--_'-_�-� ' | 208/120V | . ��� . . ��� ' | ' NEMA 3R ' L_^�"" _� L_ �"" _J L_ | | ----��---- ----l----- ------ ------------ ------------ I-- ------ EXISTING ------- NEW 15KVV AHU-2/ /\��-1 HEAT ��/�� �-���� �-_ ��6 0_ [----1 " 12 r--- -1 ~ 60 F----1 ~ 35 L- T _� / L_ T _J ' L_ T _J ' / . . | | | �_________________� L {��TT�� _ _-----------1 -------- |-- || { / | \ | | | | [---�---� �---�-- [— --�---1 ''"`EL | | ' ��K�� ' | ` | | | ' P���� | | | | ' PAN EL ' | | |` ' | ' | [��(� | ' ' ' | ' ' | ' | ��� | � � | ' ' | ' | p�� | ' � � | | ' |/F0�k�E�LY| ' | '� ' \ \ | ' |/FO�W��LY| | �` � | | | ' |/FOR�W��LY| ' | �` � | ' | '�B'\ N| ' | ' / m' | ' | 'BA'\ N| | � / m� | ' | 'BB'\ N| ' | � / m� | 225A | ' ' | | ' (l. ' | � | ' [>0A ' ' | | | ' ��'[~[}' ' | ' ��{}0A ' | ' | | ' | ' M'[~(]' ' | L___� . �"" | | ' ��0V ' L_ �~~ | ' 2{}820V | | 2(}�� ������� POWER ��N������ ��U�&�������� U���� ������� ������ ��N^����^�U�UNOT TO SCALE POWER RISER DIAGRAM NOTES: 09) REFERENCE NOTE ON DRAWING 1. EXISTING WIRE AND CONDUIT TO REMAIN. 2. SEE PANEL SCHEDULE FOR WIRE AND CONDUCT SIZES. 3 G SETS: /4\#400. 3^ C. P PHOTOCELL AT ROOF PANEL PANEL PANEL PANEL PANEL PANEL CHE.c^ S PANEL TYPT�CTOR/TIME CLOCK FPL FOR UPGRADE OF ELECTRICAL 4. CONTRACTOR SHALL COORDINATE: WITH SERVICE '''- ''''-FORMER IF REOUpE" R TO BID. ALL FPL REQUIREMENTS SHALL BE INCLUDED ELECTRICAL DESIGN AS PART OF THE 80. � O0D CONTROL SYSTEM VY�H /3\ �12 5. CONNECT SHUNT TRIP BREAKERS T0 n' ` / « ' THESE PLANS ����0 --._~~~rro�PO�EQWONK ARE sUBJECT TO ANY COO REOW���������� '--~~'°= -'---~'O""=/»mmT K��� '~~'-~�����SA0yjr4 70 COMPLY WITH ��/\[- -°��m.� _L~C=DES. CA uj Ld THIS DRAWING mAN INSTRUMENT orSERVICE AND THE PRuPEKY OF BASHAuDESIGN AND SHALL nswmw r*on pmopcnn. THE USE OF THE unm*/wo m RESTRICTED no THE ORIGINAL SITE FOR w*/u* IT IS peo=mRco AND puouoATIow r*cncor IS cxpncoocr uwnEo TO SUCH USE. le� BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -LANDSCAPE 7645K]AIE PARKWAY, #201 JAC&SONVILLE,FLCU0IcuA 32350 (904)731'2323 FAX (904)73|'2699 Wcho6o: *ww:banhamlucoa.uom DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E 5,0 4" SQUARE - DEVICE BOX BOX DEVICE COVER WITH RAISED RING OF PROPER m DEPTH AND TYPE FOR WALL CONSTRUCTION. RING TO FINISH FLUSH WITH WALL m �I m DEVICE TRIM PLATE OR EMT, CONNECTORS SHALL {,E COMPRESSION TYPE, WITH IPJSULATE:D THROAT MAKE CIRCUIT JOINT WITH TWIST —ON CONNECTOR, AND CONNECT TO DEVICE WITH SINGLE LEADS. 1#12 AWG GREEN INSULATED JUMPER TO BOX BONDING -, SCREW 1#12 AWG GREEN INSULATED JUMPER TO DEVICE GROUNDING SCREW NOT TO SCALE TYPICAL DUPLEX RECEPTACLE INSTALLATION BRANCH CIRCUIT CONDUIT JUNCTION BOX ATTACHED TO STRUCTURE 6 FT MAX. LENGTH OF FLEXIBLE CONDUIT TO ALLOW FOR RELOCATION. INCLUDE GROUND WIRE. MAXIMUM OF THREE (3) FLEX. RUNS PER JUNCTION BOX. /-LAY-IN TYPE FLUORESCENT TROFFER SEE LIGHTING FIXTURE SCHEDULE FASTEN TO CEILING MEMBER BY BOLTS, SCREWS OR RIVETS AT 2 LOCATIONS OF EACH OF THE TWO LONG SIDES. TYPE "G" INVERTED "T" CEILING GRID. SECURE FIXTURE TO GRID WITH APPROVED METHOD, FOUR PER FIXTURE. TYPICAL LAY -IN FIXTURE INSTALLATION - DETAIL EMERGENCY LIGHT NORMAL LIGHT LOCAL OFF SWITCH NE ANY UNE VOLTAGE OCCUPANCY SENSOR USING TERMINALS NYLON BUSHING NYLON BUSHING LAY —IN CEILING (TYP) - 1 "E.C. WITH 1 "E.C. WITH PULLSTRING PULLSTRING TELEPHOI BOARD wi TYPICAL TEL./DATA OUTLET GROUND BUS #6G, 3/4" C. TO PANEL GROUND 2 1 /2"C. TO ABOVE CEILING —PROVIDE BUSHING (TYPICAL) PROVIDE 4'X4' TELEPHONE BOARD PAINTED WITH GREY FIRE RETARDANT PAINT. (2) 3" CONDUITS W/ PULLSTRING TO PROPERTY LINE FOR TELEPHONE AND TV SERVICE TELEPHONE/DATA/TV SINGLE LINE DIAGRAM 12" 1 12" I 6» � GRADE FOIL BACKED RED WARNING RIBBON RED EXCAVATE AND BACIKFILL WITH EXISTING SOIL. SCHEDULE 40 P.V.C. CONDUIT 6" MIN. FILL AROUND CONDUIT WITH FINE SAND IF DIRECT BURIED CONDUIT DETAIL NOT TO SCALE PHOTOCELL EXTERIOR LIGHTING CONTACTOR J c}, TIME CLOCK PROVIDE 1-8 POLE 30 AMP <� W= TROK. DG-100 — -- — ELECTRICALLY HELD CONTACTOR W J TIMER AT PANEL —_ AND ROUTE CIRCUITS TC I THRU CONTACTOR. PROVIDE 120V POWER COIL. PROVIDE PHOTOCELL, MOUNT �II cK 6" ABOVE ROOF AND OVER RIDE SWITCH AT PANEL MARKED "EXTERIOR LIGHTING". VERIFY NUMBER OVER OF REQUIRED POLES WITH QUANTITY RIDE SWITCH OF NEW AND EXISTING EXTERIOR — LIGHTING CIRCUITS. CONTROL OUT PUT 1 * CTRL OUT -*MANSW SENSOR OCCUPANCY I Lo - COMMON USING FOUR COMMON TERMINALS C - CONTROL * CTRL OUT MAN. SW OCCUPANCY L7__ +2 SENSOR COMMON COMM MON USING FOUR TERMINALS LIGHTING MOTION SENSOR DETAILS EXTERIOR LIGHTING CONTROL DIAGRAM NOT TO SCALE RE ALARM CABLES IN CONDUIT. -TO FIRE ALARM DEVICES 120V CIRCUIT 3/4"C. TO 'TEL. BOARD DIALER SEENOTE 6 FIRE ALARM CONTROL PANEL FIRE ALARM RISER DIAGRAM NOT TO SCALE FIRE ALARM RISER NOTES 1. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT SIZED PER N.E.C. AND NFPA-70, ARTICLE 760. 2. PROVIDE AND INSTALL ANNUNCIATOR, UNIT SHALL BE FLUSH MOUNTED. 3. SEE MECHANICAL DRAWINGS FOR QUANTITIES AND EXACT LOCATIONS OF DUCT TYPE SMOKE DETECTORS, FLOW AND TAMPER SWITCHES. 4. PROVIDE FIRE ALARM SHUT -DOWN RELAYS AT ALL HVAC E=QUIPMENT. 5. REMOTE FIRE ALARM ANNUNCIATOR PANEL SHALL BE BOTH VISUAL AND AUDIBLE. RECEPTACLE WITH WEATHER PROOF COVER. SEE FLOOR PLAN FOR OUTLET RATINGS COUPLING AND PLUG TO BE FLUSH WITH FINISH FLOOR BRASS COUPLIN 6. PROVIDE AUTOMATIC TELEPHONE DIALER. COORDINATE WITH MONITORING COMPANY FOR TYPE OF EQUIPMENT. iDIALER SHALL MEET ALL REQUIREMENTS OF NFPA. 7. ALL WIRES SHALL BE IN CONDUIT. LIFE SAFETY BRANCH POWER IS SHOWN AT F.A.C.P. IF ADDITIONAL POWER IS REQUIRED IN A REMOTE POINT FROM F.A.C.P. CONTRACTOR SHALL BE RESPONSIBLE TO RUN NEW WIRING AND CONDUITS AT NO ADDITIONAL COST TO THE OWNER. 8. FIRE ALARM SHALL BE VOIC'=: EVACUATION TYPE. 9. COORDINATE WITH FIRE PROTECTION CONTRACTOR AND FINAL FIRE PROTECTION DRAWINGS TO CONNECT ALL REQUIRED DEVICES OF FIRE PROTECTION SYSTEM TCI FIRE ALARM SYSTEM. 4" x 4" x 2" STAINLESS STEEL BOX WITH GASKET COVER 2" 1-1 /2" i FINISHFn FI c GALVANIZED RIGID STEEL CONDUIT SURFACE MOUNTED FLOOR OUTLET DETAIL (KITCHEN) NOT TO SCALE 24" X 36" 30"D HANDHOLE QUARZITE: BOX #PG2436BB30, COVER #PG2436HA00 -7 37" 8" 8' log -9 0 • • • • CRUSHED ROCK OR GRAVEL CONDUIT AS SPECIFIED ON DRAWINGS I►inTrc•_ 11 PREPARE THE EXCAVATION APPROXIMATELY 6" DEEPER THAN BOX, THEN ADD 8" OF GRAVEL OR CRUSHED ROCK FOR DRAINAGE. 12 PLACE BOX IN HOLE WITH TOP AT GRADE LEVEL. Q FILL WITH COMPACT SOIL TO GRADE LEVEL WITH COVER ON BOX. ® PROVIDE FLEXIBLE SEALANT AT ENDS OF CONDUITS AROUND CABLES. CONCRETE HANDHOLE DETAIL NOT TO SCALE GRADE T FLOOD -1G`HT DETAIL NOT TO SCALE THESE PLAINS ANU ALL PnOPOSEA WORK ARE SUBJECT TO ANY CORRECTIONS REQUIROD BY PIEL® INSPECTORS THAT I'r'AY BE NECESSARY IN OnDa m COMPLY WITH ALL APPLICAOLE CODES. m m z o_ Q ~ 9= z w 0 q In O_ w 04 t 0 1 az mmml THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC. PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lie. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E5,02 Ee C SWBD M DP MOUNTING: STYLE: ENCLOSURE TYPE: SURFACE SQ. D QO NEMA 3R VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE AMPS: 2000 M.C.B. OR M.L.O: MCB AIC RATING 65,000 CIR BREAKER LOAD NUM DESCRIPTION POLE SIZE WIRE/CONDUIT KVA 1 SURGE PROTECTION 3 60 2 PANELS P3A/P3B/P3C 3 225 (4) #4/0, #4G, 2 1/2" C. 74.8 3 PANELS P4A/P4B 3 225 (4) #4/0, #4G, 2 1/2" C. 56 4 PANEL P3D 3 400 2 SETS: (4) #4/0, #2G, 2 1/2"C. 140 5 PANEL DPA 3 1000 3 SETS: (4) #400, #2/OG, 3" C. 320 6 SPARE 3 100 7 SPACE 3 400 8 SPACE 3 400 PANEL LOAD KVA 590.7 AMPS 1641 NOTES: @ 208V, 3 PHASE 3 EX. PANEL DPA MOUNTING: SURFACE STYLE: GE SPECTRA ENCLOSURE TYPE: NEMA 3R VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE AMPS: 1000 M.C.B. OR M.L.O: MCB AIC RATING 65,000 CIR BREAKER LOAD NUM DESCRIPTION ppLE SIZE WIRE/CONDUIT KVA 1 PANEL P1A (FORMERLY PANEL A) (EX) 3 200 EXISTING 27 2 PANEL P1B (FORMERLY PANEL KA) (EX)* 3 200 EXISTING 38.4 3 PANEL P1C (FORMERLY PANEL KB) (EX)* 3 150 EXISTING 30 4 PANELS P2A/P2B (FORMERLY PANELS BA/BB) (EX) 3 200 EXISTING 34.4 5 RTU-1 (EX) 3 150 EXISTING 37.8 6 RTU-2 (EX) 3 3 150 EXISTING 22.3 7 RTU-3 (EX) 80 EXISTING 23 8 ACCU-1 (EX) 3 45 EXISTING 10.1 9 ACCU-2 (EX) 3 3 50 EXISTING 8.9 10 AHU-1/2, STRIP HEAT (EX) 100 EXISTING 25.9 13 CHEF'S PANEL * 3 125 (3) #1, #6G, 1 1/2" C. 36 14 COMBO OVEN * 3 125 (3) #1, #6G, 1 1/2" C. 23 PANEL LOAD KVA 316.8 AMPS 880 @ 208V, NOTES: 3 PHASE * 65% DEMAND FOR KIT. EQ. INCL. MOUNTING: FLUSH PANEL P 1 C VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 225 M.C.B.TIN PNL KBL. EXISTING f4�.C.B. 0., .� O. NEMA 1 MLO ENCLOSURE TYPE: ( ) AIC RATING EXISTING CIR BREAKER LOADPHASE (LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C ,KVA. O, SIZE -U�IIRE/C�JIyQIJ1T. DJ<S,C�IP,TI�f�L _ ,. I�U1Vl 1 MOBILE HEATED CABINET #10,#10G , 1/2" 30 1 2 X ' 1 X ( X X > X JC X X i'' X X X X X X X X X X X X 1.9 1 20 EXISTING EXIST. HOOD EXH. 2 3 GAS SKILLET (50) #12,#12G, 1/2" 1 20 1 0.1 1.9 1 20 EXISTING EXIST. HOOD EXH. 4 5 SHUNTTRIP 1.9 1 20 EXISTING EXIST. HOOD SUPPLY 6 7 GAS RANGE/DUAL OVENS (611 #12,#12G, 1/2" 20 1 1.8 0.4 3 20 #12,#12G, 1/2" HOOD MUA FAN 8 9 SHUNTTRIP 0.4 ) 10 11 ROTISSERIE OVEN (1) #8,#10G, 3/4" 50 3 3.9 0.4 ) 12 13 ) 3.9 0.7 1 20 #12,#12G, 1/2" HOOD LIGHTS/CONTROLS 14 15 ) 3.9 0.2 1 20 #12,#12G, 1/2" WORK TABLE (105) 16 17 SHUNTTRIP 0.9 1 20 #12,#12G, 1/2" SODA SYSTEM (106) 18 19 POS (82) #12,#12G, 1/2" 20 1 1.2 0�, ,_11` _,2G #T2;#12G; 1/2" 'GAS-FRYERS'(65)''� � � ` "_20 21 POS (82) #12,#12G, 1/2" 20 1 1.2 SHUNTTRIP 22 23 SODA DISPENSER (90) #12,#12G, 1/2" 20 1 1.5 1 120 SPARE 24 25 REFRIG. CHEF BASE (62) #12,#12G, 1/2" 20 1 0.9 27 SHUNTTRIP 0.2 1 20 #12,#12G, 1/2" BEVERAGE TABLE (76) 28 29 PIZZA OVEN (55,56) #12,#12G, 1/2" 20 1 0.4 31 EXIST. ICE MACHINE #12,#12G, 1/2" 20 3 1.3 0.2 1 20 #12,#12G, 1/2" BEVERAGE TABLE (89) 32 33 ) 1.3 35 ) 1.3 0.6 1 20 #12,#12G, 1/2" BOTTLE COOLER (112) 36 37 ICE TEA BREWER (93) #12,#12G, 1/2" 20 1 1.8 1.8 1 20 #12,#12G, 1/2" COFFEE BREWER (87) 38 39 REACH -IN REFRIG. (94) #12,#12G, 1/2" 20 1 0.8 1:8,: - -- - 2�. #1 ,#3 G, /2"- QFFEK BRIrWE8,j-8-7 - .,;: --AO 41 SODA DISPENSER (104) #12,#12G, 1/2" 20 1 1.5 0.2 1 1 1 20 #12,#12G, 1/2" I BEVERAGE TABLE(9 42 PANEL LOAD KVA AMPS NOTES: PHASE A 19.6 163 1,2,8 PHASE B 12.5 104 PHASE C 14:4 120 TOTAL 46.5 j 129 @ 208V, 3 PHASE X 65% DEMAND: 30.225 KVA IX MOUNTING: FLUSH PANEL PIA VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 200 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL A) M.C.B. OR M.L.O: MLO AIC RATING EXISTING CIR BREAKER LOADPHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 LIGHTS - KITCHEN #12, #12G, 1/2" 20 1 1.7 X X X X X X'0:5 Ix I\ X 1 `� X X,' X X X1 ',,X ;' ' X,' ', X XI' \> X �'� X 1.5 1 20 EXISTING EX. BANQUET LIGHTING 2 3 EX. BANQUET LIGHTING EXISTING 20 1 1.5 1.5 1 20 EXISTING EX. BANQUET LIGHTING 4 5 EX. BANQUET LIGHTING EXISTING 20 1 1.5 0.5 1 20 EXISTING EX. BANQUET FB 6 7 EX. BANQUET FANS EXISTING 20 1 1.5 0.5 1 20 EXISTING EX. BANQUET RECEPT 8 9 REC-BAR GP #12, #12G, 1/2" 20 1 0.4 0.5 1 20 EXISTING EX. BANQUET RECEPT 10 11 SPACE 1_' ,'20-- EXISTING _ -`� EX BAl',lQUFFRECFPT 13 SPARE (EX) 20 1 1.4 1 20 #10, #10G, 1/2" PRIVATE DINING/SALES LTG 14 -��20, ,, 1 - 1 20 SPARE 16 17 LIGHTS -BAR #12, #12G, 1/2" 20 1 0.2 �1' 1� 20- EEXtStiINd "'EXSTI�I�C(GFtI ING" �' "18 . 19 REC-112,113 #12, #12G, 1/2" 20 1 0.4 1.2 1 20 #12, #12G, 1/2" KIT. GEN'L. RECEPTS 20 21 REC-111, TV #12, #12G, 1/2" 20 1 0.6 0.2 1 20 #12, #12G, 1/2" EXTERIOR RECEPTS 22 23 RESTAURANT CHANDELIERS #12, #12G, 1/2" 20 1 1 0.6 1 20 #12, #12G, 1/2" KIT. OFFICE RECEPTS 24 25 SPARE 20 1 1- 20 SPARE-.,,-'�.� „- _� __, ��._2..- 27 RESTAURANT DOWNLIGHTS #12, #12G, 1/2" 20 1 1.3 1 20 SPARE (EXISTING) 28 29 REC-111, TV #12, #12G, 1/2" 20 1 0.6 1 20 SPARE (EXISTING) 30 31 SPARE 20 1 1 20 SPARE (EXISTING) 32 33 EX. RESTAUARNT RECS EXISTING 20 1 1 0.2 1 20 #12, #12G, 1/2" REC 34 35 EX. RESTAUARNT RECS EXISTING 20 1 1 20 SPACE 36 37 COOLER/FREEZER/KITCHEN LT #12, #12G, 1/2" 20 1 0.7 0.7 3 20 #12, #12G, 1/2" HOOD EXHAUST FAN 38 -39 400C3tT;/ff)�CtTRbt � -'��- # 12jtl2t; Y/2" ^ 20_ __1 __ -'0:3 0.7 ) 40 41 BEVERAGE TABLE #12, #12G, 1/2" 20 1 0.3 0.7 ) 42 PANEL LOAD KVA AMPS NOTES: PHASE A 9.6 80 1,8 PHASE B 8.2 68 PHASE C 7.9 65 TOTAL 25.7 ' 71 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL P2A VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: 3E POWERMARK AMPS: 200 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL BA) M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOADPHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 EX. LOBBY LTS - PENDANTS EXISTING 20 1 1.8 X X X X -.� X X, ` X X X X X X X X 0.5 1 20 EXISTING MERCH. STORAGE LIGHTS 2 3 EX. LOBBY LTS - PENDANTS EXISTING 20 1 1.8 0.5 1 20 EXISTING ATTEND/DRESSING - LIGHTS 4 5 EX. LOBBY LTS - SCONCE EXISTING 20 1 1.8 X 0.5 1 20 EXISTING EXISTING CIRCUIT 6 7 EX. LOBBY LTS - SCONCE EXISTING 20 1 1.8 0.5�- ��- .,/20- FX(S-TING -EX.-CLRCUIS- ,,, -- _,8 9 EX. PRO SHOP FLOOR BOX EXISTING 20 1 0.5 0.4 1 20 #10, #10G, 3/4 EXTERIOR LIGHTING 10 11-..,E�E:-SOUJU.D-'SY�STM - --XITIIdC 2Qi�.I- �.F}:5._ X 77 _ ,_, ;PACE S 12 13 REC - PLATFORM #12,#12G / 1/2" 20 1 0.7 SPACE 14 15 SPARE 20 1 SPACE 16 17 LIGHTED DISPLAY #12,#12G / 1/2" 20 1 1.5 X SPACE 18 19 REC 5 #12,#12G / 1/2" 20 1 1-3 SPACE 20 21_ .___. . ,. -SPARE- . \ 2d __ 1 SPACE 22 23 SPARE 20 1 X SPACE 24 25 SPARE 20 1 SPACE 26 27 SPARE 20 1 SPACE 28 29 SPARE 20 1 X SPACE 30 31 SPARE 20 1 SPACE 32 33 SPACE SPACE 34 35 SPACE X SPACE 36 37 SPACE SPACE 38 39 SPACE SPACE 40 41 SPACE X SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 6.6 55 1,8 PHASE B 3.2 26 PHASE C 4.3 35 TOTAL 14.1 39 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL P 2 B VOLTS & PHASE: 208/120V, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 200 ENCLOSURE TYPE: NEMA 1 ( EXISTING PNL BB) M.C.B. OR M.L.O: MLO AIC RATING EXISTING CIR BREAKER _ LOADPHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE ' WIRE/CONDUIT DESCRIPTION NUM 1 EX. CIRCUIT EXISTING 20 1 0.5 X X X X X X X X ' X' ', X( ,X X `, X \ X X X SPACE 2 3 EX. CIRCUIT EXISTING 20 1 0.5 SPACE 4 5 EX. RECEPTACLES EXISTING 20 1 1 X SPACE 6 7 EX. RECEPTACLES EXISTING 20 1 1 SPACE 8 9 EX. RECEPTACLES EXISTING 20 1 1 1 1 20 EXISTING EXISTING CIRCUIT 10 11 EX. EXIT LIGHTS EXISTING 20 1 0.5 X SPACE 12 13 EX. TELEPHONE BOARD EXISTING 20 1 0.5 SPACE 14 15 EX. OFFICE REC. EXISTING 20 1 1 1 1 20 EXISTING EX. IG COMPUTER 16 17 EX. OFFICE REC. EXISTING 20 1 1 X 1 20 SPARE 18 19 EX. LOBBY REC. EXISTING 20 1 1 1 1 20 EXISTING EX. WALL LIGHTING 20 �._ -EX.._.LOBBYAEC, ti..�_�r EXiSTING1� � : 2A.- -� - �� ram, -1. ,�- _ 29 ICISTI � .. €X,.ka�,-HTI1V ------ 23 PRO SHOP FLOOR BOX #12, #12G, 1/2" 20 1 0.4 X" 2 30 SPARE (EXISTING) 24 25 PRO SHOP FLOOR BOX #12, #12G, 1/2" 20 1 0.4 ) 26 27-' 'EX FYRE AtAkM`PANEL` - -' -EXIST146 -' 20 ;'-1 0.5 0.2 1 20 EXISTING EX. LIGHTING 28 29 EX. RECESSED LTG EXISTING 20 1 1 1 20 SPARE 30 1.2 1 20 #12, #12G, 1/2" PRO SHOP PENDANT LTG 32 33 EX. LIGHTING EXISTING 20 1 1.5 1 1 20 EXISTING EX. LIGHTING 34 35 EX. LIGHTING EXISTING 20 1 0.9 X ������� -� - "SPACE 36 17 _X-. WALL NGHT-S`- EXt5T{NG- _ , 20,- �1 , ��.;- UNUSABLE SPACE 38 39 OFFICE 121/122 LIGHTS #12, #12G, 1/2" 20 1 0.3 UNUSABLE SPACE 40 41 EX. EXIT LIGHTS EXISTING 1 0.5 UNUSABLE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 7.6 63 1,8 PHASE B 10 83 PHASE C 5.3 44 TOTAL 22.9 63 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL P 1 B VOLTS & PHASE: 208/12OV, 3 PHASE, 4 WIRE STYLE: EXISTING AMPS: 200 ENCLOSURE TYPE: NEMA 1 (EXIST. PNL KA) M.C.B. OK M.L.O: MLO AIC RATING EXISTING CIR BREAKER ILOADPHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 W/1 COOLER EVAP. (2) #12,#12G, 1/2" 20 1 0.2 X X X X X X X X X X X X X X 1 2 20 #12,#12G, 1/2" FREEZER EVAP (6) 2 3 BEER COOLER EVAP (4) #12,#12G, 1/2" 20 1 0.2 1 ) 4 5 FzR DOOR HEAT/LIGHTS (1) #12,#12G, 1/2" 20 1 1.2 X 1.2 3 20 #12,#12G, 1/2" W/I COOLER CU (3) 6 7 SODA SYSTEM (14) #12,#12G, 1/2" 20 1 0.9 1.2 ) 8 9 BENCH MIXER (16) #12,#12G, 1/2" 20 1 1.5 1.2 ) 10 11 FOOD PROCESSOR (18) #12,#12G, 1/2" 20 1 1.5 X 0.7 3 20 #12,#12G, 1/2" BEER COOLER CU (5) 12 13 DISPOSER (21) #12,#12G, 1/2" 20 3 0.7 0.7 ) 14 15 ) 0.7 -0.7 _ -, 17 ) 0.7 X 1 3 100 (4)#3,#8G,1 1/4" PANEL P1B2 18 19 MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 1 ) 20 21 MOBILE PREP (36) #12,#12G, 1/2" 20 1 1.5 `, 1 ) 22 23 AIR CURTAIN #12,#12G, 1/2" 20 1 1 X--' /�. -20_ ^� ��._ ........ 25 HOBART FLOOR MIXIER (10) #12,#12G, 1/2" 20 3 0.7 1.1 3 20 #12,#12G, 1/2" FREEZER CU (7) 26 27 ) 0.7 1.1 ) 28 29 ) 0.7 X 1.1 ) 30 31 BOOSTER HEATER (30) #6,#10G, 1" 60 3 5 0.8 3 20 #12,#12G, 1/2" DISPOSER (31) 32 33 ) 5 0.8 ) 34 35 ) 5 X 0.8 ) 36 37 DISHWASHER (29) #6,#10G, 1" 60 3 5.5 0.6 1 20 #12,#12G, 1/2" BOTTLE COOLER (1.16) 38 39 ) 5.5 1 20 SPARE 40 41 ) 5.5 X 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 20.85 173 1,2,8 PHASE B 20.85 173 PHASE C 20.4 170 TOTAL 62.1 `, 172 @ 208V, 3 PHASE X 65% DEMAND = 40.365 KVA ` . ` ®`-SODA t SPARE SPARE SPARE • • y ® SPACE -- SPACE SPACE ® ®-- !SPACE SPACE / / a /m/mmm / i i E/ / y • y 1� PANEL SCHEDULE NOTES: ® REFERENCE NOTE ON DRAWING 1. CIRCUITS MAY BE GANGED TOGETHER WITH THE WIRE SIZES INDICATED FOR UP TO THREE CURRENT CARRYING CONDUCTORS IN A CONDUIT. WHEN THE NUMBER OF CURRENT CARRYING CONDUCTORS EXCEEDS THREE, WIRES SHALL BE UPSIZED AND DERATED IN ACCORDANCE WITH NEC TABLE 310.15(B)(2)(a). CONDUIT SIZES SHALL BE ADJUSTED TO COMPLY WITH NEC TABLES FOR CONDUCTOR FILL BASED ON CONDUIT TYPE. 2. CONTRACTOR SHALL VERIFY ALL KITCHEN EQUIPMENT POWER REQUIREMENTS PRIOR TO INSTALLATION. 3. SERVICE ENTRANCE RATED. 4. INSTALL NEW BREAKER IN EXISTING PANEL. 5. PROVIDE SHUNT TRIP BREAKER. 6. ROUTE THROUGH LIGHTING CONTACTOR. 7. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL TRIP BREAKER. 8. PRIOR TO BID FIELD VERIFY WHICH BREAKERS MAY BE RE -USED AND WHICH BREAKERS ARE REQUIRE TO BE NEW. I a1.PLA N, A IC ALL PE` 3,00--1) ARE SUBJECT TO ANY CODA 'CTIUIVS REQUIROD BY PIELA I' iCTOMS TI,IAT 141Y RE NECE%Aay IN CADEM TO C'0MPLy WITH A!nL pPrZ,I�.�F3�,E CO�E�• m m r7 z ®~ � z Yf O � N o N �j a --I w I 0 0 I o a z 11 1 1 1 Li THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. ^ll VJ •� w .� O ct • 40 V 1 V r� O • � A w • n• BASHAM & LUCAS DESIGN GROUP, INC. PLANNING •ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E6,0 LENTING: SURD SUFACE STYLE: SQRD MOUNTING: PANEL P3A AMPS:& PHASE: 208/120V, 3 PHASE,4 212E ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOADPHASE LOAD BREAKER CIR N-UM",". ,, - DESGf31RTj¢N�, ,WIRE/CQN-DUJT ,,SIZ-E .POL.E <YA,, A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-MEMBER DINING #8, #8G / 3/4" 20 1 0.7 X `; X X X X X X X X X X X X X `, X X X X `X X X 0.4 1 20 #12, #12G / 1/2" FACP 2 3 REC-MEMBER DINING #8, #813 / 3/4 20 1 0.5 0.9 ,;-1 .-20; 41,2, #12Gj1/Z REC-15.E�}-- 5 REC-DINING SERVICE #8, #8G / 3/4" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-147 6 7 - REC DINING SERVICE # #8G 3 4" 8, / / 20 1 0.2 b 2 412- 2G "_.:I._ V / REC- 9 REC-DINING SERVICE #8, #8G / 3/4" 20 1 0.2 0.5 1 20 #12, #12G / 1/2" REC-147 10 11 REC-LOCKER 130 #10, #10G / 1/2 20 1 0.5 0A` 20-- 412, #12G / 1/2 REC-147" 12 13 REC-LOCKER 120 ,._ " 412,#i26 11j2" 10 1 -0-2 0.2 1 20 #12, #12G / 1/2" REC-150 14 15 REC-LOCKER 130 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-150 16 17 REC-LOCKER 132 #12, #1213 / 1/2" 20 1 0.2 0.2 1 20 #12, #12G / 1/2" REC-151 18 19 REC-LOCKER 132 #12, #12G / 1/2" 20 1 0.2 0,5 ", -1 .� 29- 121 #12G,/ -1/2" RFC-150 20-j 21 REC-LOCKER 137 #12, #12G / 1/2" 20 1 0.2 1 20 SPARE 22 23 REC-132, 134, 138 #12, #12G / 1/2" 20 1 0.5 -0.9 ` 1 _ `20'" #12, ##i2Gj'i/-2" RE-t-1 '' `� ' - ` �24' 25 REC-143 #12, #12G / 1/2" 20 1 0.4 0.2 1 20 #12, #12G / 1/2" REC-145 26 -2T REC-143 - -�,- 12,-#j2Gj l/- " -�0 1_� -0.4_ 0.4 1 20 #12, #12G / 1/2" REC-124 FLOOR BOXES 28 29 REC-123, 140 #10, #10G / 1/2" 20 1 0.9 1 20 SPARE 30 31 DISPLAYt1GkTINCi --- ` " ,_y #12,'#12Gf'1/2`r`2U� -1` 1 � 1 20 SPARE 32 33 DISPLAY LIGHTING #12, #12G / 1/2" 20 1 1 1 20 SPARE 34 EXEC 1 -0 141�, v.- �.- �_ #12-#1.20./ 1/Z" 20 , -1- 0.,4 1 20 SPARE 36 37 REC-159 #10, #10G / 1/2" 20 1 0.5 1 20 SPARE 38 39 REC-157 #10, #10G / 1/2" 20 1 0.7 1 20 SPARE 40 4 ' REC458-" `- �__ _�' #i2�#12G j`3/2'" -20- 3-= o.4 1 20 SPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 4.7 39 1,2 PHASE B 5.4 45 PHASE C 5 41 TOTAL 15.1 41 @ 208V, 3 PHASE URFACE PANEL P3 D & PHASE: 208/120V, 3 PHASE, 4 4IRE MOUNTING: SD NQOD AMPS: STYLE: SU ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOAD HAS LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 RTU-1 #8, #10G, 1" 3 45 3.8 X X X X X X X X- X X X > X X X X X X X X X X 0.1 2 15 412, #12G, 3/4" FCU-1 2 3 ) 3.8 0.1 ) 4 5 ) 3.8 0.1 2 15 #12, #12G, 3/4" FCU-2 6 7 RTU-2 #8, #10G, 1 3 45 3.8 0.1 ) 8 9 ) 3.8 0.1 2 15 #12, #12G, 3/4" FCU-3 10 11 ) 3.8 0.1 ) 12 13 RTU-3 #2, #8G, 1 1/2" 3 100 8.2 0.1 2 15 #12, #12G, 3/4" FCU-4 14 15 ) 8.2 17 ) 8.2 2 3 30 #10, #10G, 3/4" HP-1 - CIRCUIT A 18 19 RTU-4 #2, #8G, 1 1/2" 3 100 9.5 2 ) 20 21 ) 9.5 2 ) 22 23 ) 9.5 1 20 SPARE 24 25 RTU-5 #2, #8G, 1 1/2" 3 100 8.2 1 1 2 �T#121--#1�2O,3t4" _WS-NORTH _ 26 27 ) 8.2 -1 ", 1 ,2-0,-#1-0,-#10G;_3/4�" EF'SSOUTH-- - - -28- 29 ) 8.2 2 3 30 #10, #10G, 3/•?" HP-1 - CIRCUIT B 30 31 RTU-6 #2, #8G, 1 1/2" 3 100 8.2 2 ) 32 33 ) 8.2 2 ) 34 35 ) 8.2 _ __ . _ SPACE ' ; .36 - 37 SPACE SPACE 38 39 SPACE SPACE 40 41 ISPACE SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 47 391 PHASE B 47 391 PHASE ; 45:9 --, 382 _ TOTAL 139.9 388 @ 208V, 3 PHASE PANEL SCHEDULE NOTES: ® REFERENCE NOTE ON DRAWING 1. CIRCUITS MAY BE GANGED TOGETHER WITH THE WIRE SIZES INDICATED FOR UP TO THREE CURRENT CARRYING CONDUCTORS IN A CONDUIT. WHEN THE NUMBER OF CURRENT CARRYING CONDUCTORS EXCEEDS THREE, WIRES SHALL BE UPSIZED AND DERATED IN ACCORDANCE WITH NEC TABLE 310.15(B)(2)(a). CONDUIT SIZES SHALL BE ADJUSTED TO COMPLY WITH NEC TABLES FOR CONDUCTOR FILL BASED ON CONDUIT TYPE. 2. PROVIDE SUB —FEED LUGS. 3. CONTRACTOR SHALL VERIFY ALL KITCHEN EQUIPMENT POWER REQUIREMENTS PRIOR TO INSTALLATION. 4. CONNECT SHUNT TRIP TO HOOD FIRE SUPPRESSION SYSTEM. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHALL TRIP BREAKER. 5. ROUTE THROUGH LIGHTING CONTRACTOR. C MOUNTING: SURFACE PANEL P3 B VOLTS & PHASE: 208/120V, 3 PHASE, 4 WIRE STYLE: SQ. D NQ AMPS: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOADPHASE BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B CPOLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 LIGHTS-123,1,6,127 #10, #10G1/2" ��20 1' b.7., X X; X X X X X X ,X X` X X X X rLOAD 1 20 #12, #12G, 1/2" LIGHTS - MERCH. STOR. 23 LIGHTS - MEMBER DINING #8, #8G, 3/4" 20 1 0.7 , � 1' '20" #10,,#10G,�1/2"' EXTERIOR LIGHTS- S'�'' .. 5 LIC2HTS,- MEMBER DINING #8, #8G, 3/4" 20 1,11 1,5� X 0.8 1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LOCKER 146 6 ; 7-- LIGHTS-JyAE-MB-ER,BAR - #"10,,#10G; 1/2", 20- 1 1. - 0.6 1 20 #12, #12G, 1/2" LIGHTS - WOM. LAV. 147 8, 9 SPARE 20 1 0.6 1 20 #12, #12G, 1/2" LIGHTS - MENS LOCKER 151 1( r� lIG-HTS, ffAttS 26` 1, X 0.8 1 20 #12, #12G, 1/2" LIGHTS -MENS LAV. 149 12' 13 LIGHTS - MTG & ANTI ROOMS #12, #12G, 1/2" 20 1 0.9 1.1 1 20 #12, #12G, 1/2" LIGHTS - WOM. LOCKER 137 14 15 LIGHTS - GALLERY #12, #12G, 1/2" 20 1 1.7 1.4 20 #12, #12G, 1/2" LIGHTS- WOfvA: LAV. -136 --l.16- 17 DISPLAY CASES - GALLERY #12, #12G, 1/2" 20 1 1.8 X 0.4 1 20 #12, #12G, 1/2" LIGHTS - MENS LAV. 149 18 19 LIGHTS -TERRACES #10, #10G, 1/2" 20 1 1.1 1.6 1 20 #10, #10G, 1/2" LIGHTS - MENS LOCKER 151 20 21 LIGHTS - TERRACES #10, #10G, 1/2" 20 1 1 1 20 SPARE 22 2�--LlGHT5-TERRACE$- _ # 12-,,#126 1-/2-- 20 1..141. k 1 20 SPARE 24 25 LIGHTS - PAVILION #8, #8G, 3/4" 20 1 1.5 1 20 SPARE 26 27 SPARE 20 1 j 1 20 SPARE 28 29''-SPARE X 1 20 SPARE 30 31 LIGHTS - GALLERY #12, #12G, 1/2" 20 1 1.8 1 20 SPARE 32 33 LIGHTS 119 #12, #12G, 1/2" 20 1 1.6 20 34` 35, EIGHTS 1,19 ,., . ,#12, #12G,-1/2"--, 2fl" - -I - � X 1 20 SPARE 36 37 LIGHTS -TERRACE #12, #12G, 1/2" 20 1 1.4 1 20 SPARE 38 39 LIGHTS -TERRACE #12, #12G, 1/2" 20 1 1 1 1.4 1 20 SPARE 40 �. :._20 _ _�1. -, � X 1 20 ISPARE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 12.4 103 1,2 PHASE B 8.5 70 PHASE C 8.$ ., 73 TOTAL ! 29.7 82 @ 208V, 3 PHASE MOUNTING: FLUSH PANEL MA VOLTS & PHASE: 208/120V, 3 PHASE, 4 WIRE STYLE: SQ. D NQ AMPS: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO AIC RATING 10,000A CIR BREAKER LOADPHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 ROLL -IN REFRIG. (122) #12,#12G / 1/2" 20 1 1 X X X X X X X X X X X X X X 5 3 60 #6,#10G / 3/4" BOOSTER HEATER (149) 2 3 REACH -IN FREEZER (123) HOOD LTS/CONTROLS (125) #12,#12G / 1/2" 20 1 1.1 5 ) 4 5 #12,#12G / 1/2" 20 1 0.3 X 5 _ ) 6 7 HOOD EXH. FAN #12,#12G / 1/2" 20 3 1.1 5.5 3 60 #6,#10G / 3/4" DISHWASHER (153) 8 9 ) 1.1 5.5 ) 10 11 ) 1.1 X 5.5 ) 12 13 HOOD MUA FAN #12,#12G / 1/2" 20 3 0.6 0.8 3 20 #12,#12G / 1/2" DISPOSER (149) 14 15 ) 0.6 0.8 ) 16 17 ) 0.6 X 0.8 ) 18 19 GAS DUAL FRYER (126) #12,#12G / 1/2" 20 1 0.8 0.9 1 20 #12,#12G / 1/2" SODA SYSTEM (156) 20 21 SHUNTTRIP 1.5 1 20 #12,#12G / 1/2" SODA DISPENSER (159) 22 23 REFRIG. PIZZA PREP TBLE(133) #12,#12G / 1/2" 20 1 1.1 X 1.8 1 20 #12,#12G / 1/2" BEVERAGE TABLE (162) 24 25 POS SYSTEM PRINTER (72) #12,#12G / 1/2" 20 1 0.3 1 20 SPARE 26 27 REFRIG. CHEF BASE (130) #12,#12G / 1/2" 20 1 0.7 1 20 SPARE 28 29 SHUNTTRIP X 1 20 SPARE 30 31 SPARE 20 1 SPACE 32 33 SPARE 20 1 SPACE 34 35 SPARE 20 1 X SPACE 36 37 SPARE 20 1 SPACE 38 39 SPARE 20 1 _ SPACE 40 41 ISPARE 20 1 1 1 X SPACE 42 r PANEL LOAD KVA AMPS NOTES: PHASE A 16 133 1,2,3 PHASE B 16.3 135 PHASE C 16.2 135 TOTAL 48.5 134 @ 208V, 3 PHASE X 65% DEMAND - 31.525 KVA MOUNTING: SURFACE PANEL P 3 C AMPS & PHASE: 208/120V, 3 PHASE, 4 WIRE STYLE: SQ. D225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: MLO Al C RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER I CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 REC-TERRACE TV'S #12, #12G, 112" 20 1 0.7 X X X X' ,X i X X X ,X X X X X X X X X 'X X X 0.2 1 20 #8, #8G, 1" REC-EVENT LAWN 2 3 GALLERY DISPLAY TVS #12 #12G 1/2" / 20 1 0.5 _ ,.2 Q i -2 --# 0 --# "-__ 8, $G 1. _, „__" .._,, ftEC EVENT"LAWN !# _ -5 GALLERY DI-SSP-I,AAY TVS- , - #12, 2G, 1�/2" 2-0 1__ ,- 0.5- 1 20 SPARE 6 7 REC _BAR TV #10G 1'S #10 2 / 20 1 0.9 0.5 1 20 #10 #10G 3 4„ / - REC ROOF TOP 8 9 MOTORIZED SERVICE DOOR #12, #12G, 1/2" 20 1 0.5 1.5 1 20 #12, #12G, 1/2" HAND DRYER 10 11 REC- 124 SERVICE #12, #12G, 1/2" 20 1 0.2 1.5 1 20 #12, #12G, 1/2" HAND DRYER 12 13 SPARE 20 1 1.5 1 20 #12, #12G, 1/2 HAND DRYER 14 15 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 16 17 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 18 19 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 20 21 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 22 23 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 24 25 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 26 27 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 28 29 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 30 31 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 32 33 SPARE 20 1 > 1.5 1 20 #12, #12G, 1/2" HAND DRYER 34 35 SPARE 20 1 1.5 1 20 #12, #12G, 1/2" HAND DRYER 36 37 SPACE 1.5 1 20 #12, #12G, 1/2" HAND DRYER 38 39 SPACE 1.5 1 20 #12, #12G, 1/2" HAND DRYER 40 41 SPACE 42 " PANEL LOAD KVA AMPS NOTES: PHASE A 9.8 81 1 PHASE B 10.2 85 PHASE '82� 68 TOTAL 28.2 78 @ 208V, 3 PHASE PHASE: 208/120V, 3 PHASE, 4 IRSTY:E MO ENTING: SQFLDUNaH PANEL P4 B VOLTS AMPS: 225 ENCLOSURE TYPE: NEMA 1 M.C.B. OR M.L.O: `IMLO' Al C RATING 10,000A CIR BREAKER LOAD PHASE LOAD BREAKER CIR NUM DESCRIPTION WIRE/CONDUIT SIZE POLE KVA A B C KVA POLE SIZE WIRE/CONDUIT DESCRIPTION NUM 1 GAS PIZZA OVEN (135) #12,#12G / 1/2" 20 1 0.1 X X X X X X X X X X X X X X X X X X X X X 1.8 1 20 #12,#12G / 1/2" ICE TEA BREWER (164) 2 3 PIZZA OVEN VENT FAN (136) #12,#12G / 1/2" 20 1 0.4 0.7 1 20 #12,#12G / 1/2" REFRIG. (165) 4 5 REF. SANDWICH UNIT (138) #12,#12G / 1/2" 20 1 0.7 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 6 7 SOUP WELLS (140) #12,#12G / 1/2" 20 1 1.6 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (166) 8 9 WORK TOP REFRIG. (142) #12,#12G / 1/2" 20 1 1.1 1.8 1 20 #12,#12G / 1/2" POPCORN MAKER (185) 10 11 SOUP WELLS (140) #12,#12G / 1/2" 20 1 0.8 0.2 1 20 #12,#12G / 1/2" REFRIG. (186) 12 13 SPARE 20 1 1.8 1 20 #12,#12G / 1/2" COFFEE BREWER (187) HOT DOG ROLLER (188) 14 16 15 SPARE 20 1 0.8 1 20 #12,#12G / 1/2" 17 ICE MACH. (158) #12,#12G / 1/2" 20 1 1.4 0.5 1 20 #12,#12G / 1/2" BUN WARMER (189) DRAFT BEER COOLER (178) 18 20 19 WINE CHILLER (175) #12,#12G / 1/2" 20 1 0.4 0.7 1 20 #12,#12G / 1/2" 21 BACKBAR COOLER (176) #12,#12G / 1/2" 20 1 0.7 1.3 1 20 #12,#12G / 1/2" GLASSWASHER (181) 22 23 GLASS CHILLER (177) #12,#12G / 1/2" 20 1 0.7 0.6 1 20 #12,#12G / 1/2" POS (82) 24 25 BOOSTER HEATER (180) #8,#10G / 3/4" 40 3 3.3 0.7 1 20 #12,#12G / 1/2" REC-BAR 26 27 ) 3.3 1 20 SPARE 28 29 ) 3.3 1. 20 SPARE 30 31 REC- BAR #12,#12G / 1/2" 20 1 0.4 1 20 SPARE 32 3-ai REC-KI,TC-HEN-127 #12;#l2% /,1./2" -2,0-- 1_�, 0 5 1 20 SPARE 34 35 WH-P7A #10, #10G, 3/4" 30 2 2.4 1 20 SPARE 36 37 ) 2.4 1 20 SPARE 38 39 � WH_P7 -#12,i#126/-1/2" 20' 1-�"" 0.1 SPACE j 0 41 SPACE 1 1 SPACE 42 PANEL LOAD KVA AMPS NOTES: PHASE A 15 125 1,2,3 PHASE B 10.7 89 PHASE C 12.4 103 TOTAL 38.1 105 @ 208V, 3 PHASE X 65% DEMAND = 24.765 KVA THESE PLANS AND ALL PnOPO�R) WORK ARE SUSJECT TO ANY CORRECTIONS REQUIREID BY PIELD INSPECTORS THAT rvv'lY BE NECLSSAflY IN ORDER TO COMPLY WITH ALL APPLICABLE CG E7h0. SHAFFEBL EN01 +t1pftrilt0UP,LLC 05 J. BR Y S ApERa 7R L 6 ,r •No 8168 Flop- m m G>O z 0 o_ z 0 Ui 0 Of w w I 0 0 I Toz< THIS DRAWING IS AN INSTRUMENT OF SERVICE AND THE PROPERTY OF BASHAM DESIGN GROUP, AND SHALL REMAIN THEIR PROPERTY. THE USE OF THE DRAWING IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH IT IS PREPARED AND PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. BASHAM & LUCAS DESIGN GROUP, INC, PLANNING -ARCHITECTURE -LANDSCAPE 7645 GATE PARKWAY, #201 JACKSONVILLE, FLORIDA 32256 (904) 731-2323 FAX (904) 731-2699 Website: www:bashamlucas.com Lic. Nos.: AA26000586 DRAWN BY MEM CHECKED BY JBS DATE 03-26-14 JOB NO. 13-40 SHEET NO. E6,02