Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Roofing Submittal
Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Manuf. Certification Letter Main Office: 804 Old Dixie Highway ' Lake Park, FL 33403 ■ Tel: 561.223.2096 • Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused I Date of Issue: Project: 1000 Venture Blvd, tel. 8001927--8578 www.fbertite.com FIBERTITE® ROOFING SYSTEMS Contractor Certification October 27, 2014 PGA Clubhouse at the Reserve Contractor: Therma Seal Roof Systems, LLC. 804 Old Dixie Highway Suite 6 Lake Park, FL. 33403 TO WSOMITMAYCONCERN: Wooster, Ohio 44691 fax 8001649-2737 www.seamancorp.com Seaman Corporation is the only and original manufacturer of FiberTite Roofing System(s). The above 'referenced roofing contractor is authorized to bid and install, if successful, our FiberTite Roofing System. We further certify that our system requires completion of the following criteria. a. The system .is installed by an Authorized Contractor, in strict accordance with the contract documents and current FiberTite Specifications. b. The completed system is inspected and approved by FiberTite Technical Services. C. Seaman Corporation receives full payment for materials provided. FiberTite Technical Services is available for project review at (800) 927-8578. Respectfully, Jonathan C. Pierson FiberTite Technical Services FiberTite® is a Registered Trademark of Seaman Corporation k Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Engineering Main Office: 804 Old Dixie Highway " Lake Park, FL 33403 ■ Tel: 561.223.2096 ■ Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused 0 Fax: Oct 28 2014 10:42am P005/005 gworens. Ic Engineering con'suftinca M9111188-AIME ATTACHMENT CALCULATIONS Project Name PGA Clubhouse Report No.: TRS-MB-14.007 Project address 1916 Perfect Drive Port SL Lucie, FL Deck Substrate Wood Insulated Mean Roof Height 16.0 Feet Configuration Low Slope Roof Area (Approx.) 8268 Sq.Ft. Category 11 Roof Width 53.0 Feet Exposure Condition C Perimeter Width 5.3 Feet Building Type ' Enclosed Parapet Height 3.0 Feet Base Wind Speed 170 mph Slope V 0.0 Slope H 12.0 Slope Angle* 0.00 Uplift Pressures q= = 0.00256 Kr K,, Kd V� P = C6 (GCP - GCO qz K= Ka Ka V GCP GCP 64.384 0.860 1.005 0.85 170 -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Comer Field P1 aft. -64.17 psf Pled -W.50 psf Perimeter Pa,L 407.68 psf P280 -64.61 psf Comer Pa„L-162.05 psf P390 .97.24 psf Proposed System FibsrTite Single Ply Roof System Product Approval No. 12-1019.34 (Page 8 of 13) Fastening # 1 System Design Pressure -45 psf Membrane Fun Width 54 Inches Side Lap 3 incites Net Width 51 inches Membrane Red. Width 42 inches Side Up 3 inches Net Width 39 inches Membrane Red. Width 30 inches Side Lap 3 Inches . Net Width 27 inches Fasteners FTR Magnum Fasteners and FTR Magnum Plates Fastener Spacing in Lap of Membrane 18 Inches #Rows 1 Min. Characteristic Resistance Force-286.88 IV Fastener Spacing ((MCRF/Pi) x 144)/Row Spacing Full Width Mmbrn Red. Width Mmbrn Red. WIdtA Mmbm Field Fastener Spacing 21.04 27.51 39.74 Perimeter Fastener Spacing 12.54 16.39 23.88 Comer Fastener Spacing 8.33 10.89 15.73 RECOMMENDED MEMBRANE ATTACHMENT PATTERN Field Laps @ 51" o.c. Full Width Sheet 18 Inches on center Perimeter Laps @ 510 c.c. Full Width Sheet 12 inches on center Corner Laps Q 51" o.c. Full Width Sheet 8 inches on center These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Sincerely . `Fore sicEergtonsuitans, Inc,� R. N. Saileppan; P.E. j® Principal Engineer'. 4 Florida Reg'istrrat on-:; . 4669B' ' Forensic Engineering ConsuitantE, Inc. (CA# 8M), P.O. Sox 970034, Boca Ratan, FL - 33W Ph (661) 9018490 Fax (551) 216 3830 V Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St -Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Florida Product Approval Main Office: 804 Old Dixie Highway Lake Park, FL 33403 • Tel: 561.223.2096 ■ Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused v z MAW MIAMI DADE COUNTY MEW PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidadexov/economy Seaman Corporation 1000 Venture Boulevard Wooster, OH 44691 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). , This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material'within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: FiberTite Single Ply Roof Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 11-1219.07 and consists of pages 1 through,13. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 1 of 13 v ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Single Ply Material: KEE Deck Type: Wood Maximum Design Pressure -67.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description FiberTite Various ASTM D 6754 KEE, polyester reinforced, single ply membrane FiberTite-XT Various ASTM D 6754 KEE, polyester reinforced, single ply membrane FiberTite-SM Various ASTM D 6754 KEE, polyester reinforced, single ply membrane FiberTite-XTreme Various ASTM D 6754 KEE, polyester reinforced, single ply membrane Style 80, Style 80-M Various ASTM D 6754 KEE, polyester reinforced, single ply membrane FiberTite-FB 54" x.100' ASTM D 6754 KEE, fleece -backed, single ply membrane FiberTite-XT FB Various ASTM D 6754 KEE, fleece -backed, polyester reinforced, single ply membrane FiberTite-SM FB Various ASTM D 6754 KEE, fleece -backed, polyester reinforced, single ply membrane Style 80 FB, Style 80-M FB Various ASTM D 6754 KEE, fleece -backed, polyester reinforced, single ply membrane FTR Non -Reinforced 0.060" x 54" x 24' ASTM D 6754 KEE flashing accessory FTR Cones 1" to 8" ASTM D 6754 Premolded "KEE" pipe flashing FTR Corners 2' x 2' ASTM D 6754 Premolded "KEE" corner flashing (4 per unit) FTR 190 proprietary Two side "contact" bonding adhesive FTR 190e Proprietary Solvent based bonding adhesive FTR 290 proprietary One side "substrate only" fleece back solvent based adhesive FTR 390 proprietary One side "substrate only" fleece back asphalt based adhesive FTR 490 Proprietary One side "substrate only" fleece backed water based adhesive NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 2 of 13 f TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description FiberClad 48" x 120" N/A Polymeric coated G-90 galvanized steel or stainless steel Tuff Trac 5/32" x 36" x 40' N/A Vinyl walk way; %4' x 24" x 48" Vinyl protection pad APPROVED INSULATIONS: TABLE 2 Product Name Product Description FIR -Value, FTR Value K FIR -Value Isocyanurate Insulation A, FTR Value III A ACFoam II, ACFoam-III Isocyanurate Insulation DensDeck Silicon treated gypsum H-Shield ENRGY 3 Multi -Max FA-3 SECUROCK Gypsum Fiber Roof Board Isocyanurate Insulation Isocyanurate Insulation Polyisocyanurate foam insulation Fiber Reinforced Roof Board Manufacturer (With Current NOA) Seaman Corporation Atlas Roofing Corporation Georgia-Pacific Gypsum Products Hunter Panels, LLC Johns Manville Corporation Rmax Operating LLC United States Gypsum Corporation APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. FIR Magnum Membrane fastener Various Seaman Corporation 2. FIR Magnum plate Galvalume AZ50 stress plate 1.5" x 2.5" Seaman Corporation 3. OMG Fasteners Insulation and membrane fastener Various OMG, Inc. 4. 3 in. Round Metal Plate Galvalume AZ55 stress plate 3" round OMG, Inc. 5. OMG Plastic Plate Plastic plates for fasteners. 3" round OMG, Inc. 6. Dekfast Fastener Insulation fastener for steel and Various SFS Intec, Inc. wood decks 7. Deckfast Galvalume Steel 3- Galvalume AZ50 stress plate 3" round SFS Intec, Inc. in Round Plate 8. FIR Magnum 2s Barbed, galvalume AZ50 stress 2-3/8" Dia. Seaman Corporation plate 9. FIR Magnum Plus Oval stress plate 1 %z" x 23/a" Seaman Corporation NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 3 of 13 ri EVIDENCE SUBMITTED: Test Aaency/Identifier Name Report Date Factory Mutual Research Corp. FM 4470 OR8A9.AM 03/12/94 2X2A2.AM 06/17/94 2YOA4.AM 11/01/94 FM 4470 OY7A2.AM 11/28/94 1 Y7A5.AM 12/29/95 FM 4470 1Z2A5.AM O1/12/96 FM 4470 IZ3A8.AM 08/13.97 FM 4470 30003251 10/15/99 FM 4470 3009071 01/03/02 FM 4470 3014050 07/08/03 FM 4470 3036192 11/23/09 FM 4470 3028651 04/17/08 FM 4470 3033396 09/04/09 FM 4470 3013068 09/23/03 Underwriters Laboratories UL790 94NK40647 10/15/94 95NK20862 11/17/95 98NK12810 8/11/98 98NK17212 8/21/98 Exterior Research & Design, LLC TAS 114 4015.10.96-1 Rl 07/20/10 TAS 114 4006.07.97-1 Rl 07/15/10 TAS 114 4006.08.00-1 Rl 10/18/05 Trinity I ERD TAS 114 55700.06.07-R3 09/06/07 ASTM D 6754 S34070.06.11-R1 06/18/12 TAS 117 & ASTM D6862 . C850SC.I 1.07 R1 08/07/09 ASTM D6754 534070.06.11 R3 05/30/13 FM 4470 / TAS 114 S32410.09.10 09/21/10 PRI Construction Materials ASTM D 3747 HGC-142-02-03 02/09/12 Technologies LLC NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 4 of 13 APPROVED ASSEMBLIES Membrane Type: Single Ply, KEE Deck Type 1I: Wood, Insulated Deck Description: 19/32' or greater plywood or wood plank System Type B: Base layer of insulation mechanically attached, optional top layer adhered; membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe FTR-Value, FTR Value H, FTR Value A, ACFoam-II, Multi -Max FA-3, H-Shield, ENRGY 3 Minimum 1.5" thick 6 1:2 ft2 Minimum 2" thick 6 1:4 ft2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). (Optional) Top Insulation Laver Insulation Fasteners Fastener (Table 3) Density/fe FTR Value, FTR Value H, FTR Value A, FTR Value III A, ACFoam-II, ACFoam-III, Multi-Max'FA-3, H- Shield, ENRGY 3 Minimum 1.5" thick N/A N/A Note: Apply optional top layer of insulation in a full mopping of any approved mopping hot asphalt within the EVT range and at a rate of 20-401bs/100 fe or in %11 to 1" wide beads of Insta-Stile Adhesive,12" o.c. Refer to Roofing Application Standard RAS 117 and insulation adhesive manufacturer's Roofing Component Product Control Approval for insulation attachment requirements. Insulations listed as base layer shall be used only as base layers with an optional top layer insulation installed as the final membrane substrate. Vapor Retarders: (Optional) Any UL or FMRC approved vapor retarder applied to the roof deck or over a base layer of insulation. Fire Barrier: %4" DensDeck or DensDeck Prime applied to the base or top insulation layer in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./sq. or in 3/4" to 1" wide beads of Insta-Stile Adhesive, 12" o.c. NOA No.: 12-1019.34 MIAMMADECouNTY Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 5 of 13 t Membrane: FiberTite or FiberTite XT , FiberTite-SM, Style 80 or Style 80-M roof cover adhered to the insulation with FTR 190 Bonding Adhesive or FTR 190e Bonding Adhesive applied at an application rate of 1 galJsq. to the backside of the membrane and to the substrate. Laps are sealed with 1.5-inch heat weld. or FiberTite FB, FiberTite-XT FB, FiberTite-SM FB, Style 80 FB or Style 80-M FB roof cover adhered to the insulation with approved asphalt at 20-251bs./sq., FTR 290 solvent adhesive at 1 gal. per 100 fe or FTR-390 asphalt based adhesive at 1 gal. per 60 fe or FTR-490 water based adhesive at 100 ftz/gal. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: - 45 psf (See General Limitation #9) APPROVED NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 6 of 13 Membrane Type: Single Ply, KEE Deck Type 1I: Wood, Insulated Deck Description: 19/32 1 or greater plywood or wood plank System Type C: All layers of insulation simultaneously attached; membrane fully adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Insulation Laver Insulation Fasteners Fastener able 3 Density/fe FTR Value, FTR Value H, FTR-Value A, FTR Value III A, ACFoam-II, ACFoam-III, Multi -Max FA-3,11 Shield, ENRGY 3 Minimum 1" thick N/A NIA Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. To Insulation Laver Insulation Fasteners Fastener able 3 Densi /fe DensDeck or DensDeck Prime Minimum'/a" thick 3 1:1.7 fe Minimum W' thick 3 1:1.3 fe Note: Top layers of insulation shall be mechanically attached using the fastener density listed above. Insulations listed as base layer shall be used only as base layers with an optional top layer insulation installed as the final membrane substrate. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. (See Roofing Application Standard RAS 117 for fastening details.) Vapor Retarders: (Optional) Any UL or FMRC approved vapor retarder applied to the roof deck or over a base layer of insulation. Fire Barrier: See Top Insulation Layer, above. Membrane: FiberTite , FiberTite-SM, FiberTite XT , Style 80 or Style 80-M roof cover adhered to the insulation with FTR 190 Bonding Adhesive or FTR 190e Bonding Adhesive applied at an application rate of 1 gal./sq. to the backside of the membrane and to the substrate. Laps are sealed with 1.5-inch heat weld. or FiberTite-FB, FiberTite-XT FB, FiberTite-SM FB, Style 80 FB or Style 80-M FB roof cover adhered to the insulation with approved asphalt at 20 25 lbs./sq., FTR 290 solvent adhesive at 1 gal. per 100 f or FTR 390 asphalt based adhesive at 1 gal. per 60 f? or FTR-490 water based adhesive at 100 tt2/gal. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: -45 psf (fastened at 1:1.71() (See General Limitation #9) -50 psf (fastened at 1:1.3fe) (See General Limitation #9) NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 7 of 13 Membrane Type: Single Ply, KEE Deck Type 11: Wood, Insulated Deck Description: 19/321' or greater plywood or wood plank System Type D(1): Membrane mechanically attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of any of the following insulations: Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe FTR-Value, FTR Value-H, FTR-Value A, FTR-Value III, ACFoam-II, ACFoam-III, Multi -Max FA-3, ENRGY 3, H-Shield Minimum 1.5" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Vapor Retarder: (Optional) Any UL or FMRC approved vapor retarder may be installed over the deck or the insulation. Fire Barrier: '/a" DensDeck attached with 4 fasteners per 4' x 8' sheet. Membrane: FiberTite, FiberTite-XT, FiberTite-SM, FiberTite-Xtreme, Style 80 or Style 80-M roof cover attached through the preliminary fastened insulation/barrier to the deck following one of the fastening methods specified below: astening #1: Fasten with FTR Magnum fasteners and FIR Magnum plates or FTR Magnum Plus plates spaced 18" o.c. through tabs spaced 5 1 " o.c. Laps are sealed with 1.5-inch heat weld. Fastening #2: Fasten with FTR Magnum fasteners and FTR Magnum plates or FTR Magnum Plus plates spaced 12" o.c. through tabs spaced 72" o.c. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: -45 psf (See General Limitation #7) NOA No.: 12-1019.34 MIAWMDecout�rtt Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 8 of 13 Membrane Type: Single Ply, YEE Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank fastened to supports with wood screws at maximum spacing of 6" o.c. System Type D(2): Membrane mechanically attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of any of the following insulations: Insulation Laver Insulation Fasteners Fastener able 3 Density/fe FTR-Value, FTR-Value H, FTR-Value A, FTR-Value III A, ACFoam-II, ACFoam-III, Multi -Max FA-3, ENRGY 3, H-Shield Minimum 1" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Vapor Retarder: (Optional) Any UL or FMRC approved vapor retarder may be installed over the deck or the insulation. Fire Barrier: '/a" DensDeck attached with 4 fasteners per 4' x 8' sheet. Membrane: FiberTite, FiberTite-XT, FiberTite-SM, FiberTite-Xtreme, Style 80 or Style 80-M roof cover attached through the preliminary fastened insulation/barrier to the deck following the fastening methods specified below: Fastening: Fasten with FTR Magnum fasteners and FTR Magnum plates or FTR Magnum Plus plates spaced 9" o.c, through tabs spaced 5 1 " o.c. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: -52.5 psf (See General Limitation #7) Mlar+anaoe courtnr NOA No.: 12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 9 of 13 Membrane Type: Single Ply, KEE Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached with 8d spiral nails 6" o-.c. to supports having a maximum span of 24". System Type D(3): Membrane mechanically attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of any of the following insulations: Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe FTR-Value, FTR-Value H, FTR-Value A, FTR Value III, ACFoam-II,'ACFoam-III, Multi -Max FA-3, ENRGY •3, H-Shield Minimum 1.5" thick N/A N/A DensDeck, SECUROCK Gypsum -Fiber Roof Board Minimum %11 thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having. no dimension greater than 8 ft. All layers of. insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Membrane: FiberTite, FiberTite-XT, FiberTite-SM, FiberTite-Xtreme, Style 80 or Style 80-M roof cover attached through the preliminary fastened insulation/barrier to the deck following the fastening methods specified below: Fastening: Fasten with FTR Magnum fasteners and FTR Magnum plates or FTR Magnum Plus plates spaced 6" o.c. in 5" laps spaced 5 1 " o.c. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: -52.5 psf (See General Limitation #7) NOA No.:12-1019.34 Expiration Date: O1/05/16 Approval Date: 06/06/13 Page 10 of 13 Membrane Type: Single Ply, KEE Deck Type 1I: Wood, Insulated Deck Description: '9/32' or greater plywood or wood plank attached with 8d common nails 6" o.c. to supports having a maximum span of 24". System Type D(4): Membrane mechanically attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of any of the following insulations: Insulation Laver Insulation Fasteners Fastener able 3 Density/fe DensDeck, SECUROCK Gypsum -Fiber Roof Board Minimum'/a" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Fire Barrier: See Insulation Layer, above. Membrane: FiberTite, FiberTite-XT, FiberTite-SM ,FiberTite-Xtreme, Style 80 or Style 80-M roof cover attached through the preliminary fastened insulation/barrier to the deck following one of the fastening methods specified below: ' Fastening 91: Fasten with FTR Magnum fasteners and FTR Magnum 2s plates through the top of the membrane spaced at 12" o.c. in rows spaced 72" o.c through the wood deck into structural members. Fastener rows covered with 6-inch coverstrip and sealed on both sides with 1.5-inch heat weld. Maximum Design Pressure: -60 psf (See General Limitation #7) Fastening #2: Fasten with FTR Magnum fasteners and FTR Magnum plates. or FTR Magnum Plus plates through the top of the membrane spaced at 6" o.c. in rows spaced 96" o.c. through the wood deck into structural members. Fastener rows covered with 6-inch coverstrip and sealed on both sides with 1.5-inch heat weld. Maximum Design Pressure. -67.5 psf (See General Limitation #7) Maximum Design Pressure: See Fastening Options Above. NOA No.: 12-1019.34 �Mm®�: Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 11 of 13 Membrane Type: Single Ply, KEE Deck Type 11: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank System Type E: Membrane mechanically attached to deck. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Fire Barrier: Install one of the following barrier options: 1. 1/4" DensDeck attached with 4 fasteners per 4' x 8' sheet, with joints staggered minimum 6" from plywod joints: 2. 5/8" gypsum attached to deck with four fastener per, 4' x 8' board. Increase or decrease fasteners in conjunction with the board size, maintaining the fastener density, but in no case shall there be less than two fasteners. Membrane: FiberTite, FiberTite XT , FiberTite-SM, Style 80 or Style 80-M roof cover attached to the deck following one of the fastening methods specified below: Fastening #1: Fasten with FTR Magnum fasteners and FTR Magnum plates or FIR Magnum Plus plates spaced 18" o.c. through tabs spaced 51" o.c. Laps are sealed with 1.5-inch heat weld. Fastening #2: Fasten with FIR Magnum fasteners and FTR Magnum plates or FTR Magnum Plus plates spaced 12" o.c. through tabs spaced 72" o.c. Laps are sealed with 1.5-inch heat weld. Maximum Design Pressure: -45 psf (See General Limitation #7) APPROVED NOA No.: 12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 12 of 13 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 tbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:12-1019.34 Expiration Date: 01/05/16 Approval Date: 06/06/13 Page 13 of 13 MIAMI-D E MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.poy/neraJ The Bilco Company P.O. Box 1203 New Haven, CT 06505, SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is . determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with -the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series S/NB Steel and Aluminum Roof Hatch APPROVAL DOCUMENT: Drawing titled "S/NB Door Assembly", Sheets 1 through 10 of 10, dated 10/15/2009, with last revision dated 07/07/2011, prepared by The Bilco Company, signed and sealed by Mark A. De Stefano, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance. of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 10-0113.01 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No.11-0722.10 Expiration Date: December 02, 2014 Approval Date: December 8, 2011 101Poft Page 1 The Bilco Company NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing titled "S/NB Door Assembly", Sheets 1 through 10 of 10, dated 10/15/2009, with last revision dated 07/07/2011, prepared by The Bilco Company, signed and sealed by Mark A. De Stefano, P.E. B. TESTS "Submitted under NOA # 08-1219.01" 1. Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94, 3) Cyclic Wind Pressure Test per FBC, TAS 203-94, along with marked -up drawings and installation diagram of Series NB50/20 Aluminum and Steel Roof Scuttle, prepared by Certified Testing Laboratories, Test Report No.1862W, dated I I/18/08, signed and sealed by Ramesh Patel, P.E. 2. Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 r 2) Large Missile Impact Test per FBC, TAS 201-94, 3) Cyclic Wind Pressure Test per FBC, TAS 203-94, along with marked -up drawings and installation diagram of Series S50/20 Aluminum and Steel Roof Scuttle, prepared by Certified Testing Laboratories, Test Report No.1862W-1, dated 1 l /18/08, signed and sealed by Ramesh Patel, P.E. 3. Addendum to Test Reports No. CTLA 1862W/W-1 on Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 and Forced Entry Test, per FBC 24113.2.1, TAS 202-94, dated 03/11/09, signed and sealed by Ramesh Patel, P.E. C. CALCULATIONS "Submitted under NOA # 08-1219.01" 1. Structural calculations prepared by De Stefano Engineering Group PL, dated 01/15/09, signed and sealed by Mark A. de Stefano, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA) E. MATERIAL' CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2007 and 2010 FBC, issued by De Stefano Engineering Group PL, dated 10/31/2011, signed and sealed by Mark A. de Stefano, P.E. 2. Distributor agreement dated 01/12/2010. "Submitted under NOA # 10-0113.01" 3. No financial interest letter issued by De Stefano Engineering Group PL, dated 12/08/2008, signed and sealed by Mark A. de Stefano, P.E. "Submitted under NOA # 08-1219.01" t2 0l/2�1I Carlos M. Utrera, P.E. Product Control Examiner NOA No.11-0722.10 Expiration Date: December 02, 2014 Approval Date: December 8, 2011 E -1 Detlgn Preawe ROMP I Impact Rating -1- 70 PSF I Loge and Small M6a,o lm.t ron„rournuno MOM w� 'e LOCK -2POINT - 1 a BILCO COMPANY a."t"�l.aurae acaosm r-�F•a0$TFF In:e�u, a �� • nee< aw<e J%�P`` lL` i- 9q DE emvT eFANO nnoucraevum S/NB DOOR ASSY • ij eostss� r�:.•a.r ...n ran,nr.rn. 9*.: * •;* wrt•uatrAa.aaDa r twrl.nwo L Cw>: W,.SMueEwaMhµ.rvn STATE OF r rwe.ci: M..nrwpN..nnc•a�n ria�lry.irrf►vfH Ao�IY -0 . 0 q. n^� �4 r �sru<I+e✓a.ew,rm.�xMen ana �r S/NB DOOR ASSY "'�70A(ALE E: 1:6 EiC14: SHEET I OF 10 w.xaxsrtrmo,n _""^ , •+•; •arav Mu V 0 j s ,[ �uruzs rscuMSST 1 73 SDI25 3fA•INERGLASS APE__ 2 1 ♦ 74 IW19DI GREASLINH LL ALVANIA EF2 1 ♦ NOT SHOWN ON ASSEMBLY 2 1 NOlE: S•2pRNB•205TEft VERSION SHOWN 1 - fflRS-204 N8.20 ALUMINjIjat VERSION. 1 THEIIEM NUMBERS WI1Ii El]R INDICATOR 1 I FROM.075' TOT MAT IAL iHK:KNE55 THE BILCO COMPANY ees .uamasun nw w wry ro.eo ran e+e.rra.rnee:.orcwmsos P- F „� -- rn.axa cnnctw oam r cq 4&DE STEFANO PaoouecocWm+ •i�C�Ns�.;yo v rxowrr roGROUP.vi rs.mns+ro��m.es�tr N061657 ,uesroorawxa:o.ry K:n.1m•rmSAC""'*ir. -0 0 rxcaaa.,uw S/NB DOOR ASSY *• * *i ay..w.n„iwa„� r.�so•,Nnpwa w. �i4 �• 1 �. ea.o¢aa.+aa�wAoaa aro.emi.weaav�' -- 4q STATE OF _ B �� :FcoHTo? �a r' S/NB DOOR ASSY xL� (� G �ONAI��'/ waaAaLarCMW.K uor.wscuw.a.aI ScAlE: 1:6 OHI: 91EEF20FI0 .•�' 2aao♦raarwaamsw 0 OVERA LL �l AL1 l j--FRAME OPENING LENGTH SECTION A -A ' S" DOOR WIDTH OPENECTION I@1B t R'..IL.�Rrt-ai•i'���IR��.R�>sa!if1 =• I 4'$ FRAME OPEN'.NG-- tENGTH SECTION C-C "NW' DOOR " . ° THE 81LCO COMPANY ,any uo wum r.0.w=1am "•w11o.wCwn]cipawm 11$TF� -• r�wrHau raslxnivmaoa ` DESTEFANO zausm •.rosoa�uee.mm �.•�CC�Ns�.;tyo1 exarxeraua cao+,P vc ntaiwe[Llevesea t m..affr S/NB DOOR ASSY Nas1s57 L*; ,* * aw]ar�aauru rnvunuro=n Aw.pro Ho = f0 a•..e r...�oms •+..•.bo.� ttiit�uo. 14 ....:.ero•aw _ q: STATE Of.•., su✓wrac.+..mxa. /NB DO r4 GTI&t•bMAu.•pk�4•b.•a. =rni g " S/N8 DOOR ASSY XL�. �•�;�ORIOP:�@� o� S�O/vA1.ENG u=an�o=arzrwgsr F� SCALE'. 1:7 EKallf: SHEET30F 10 R11raOrRATgAaa/19 WIDTH SECTION D-D OPEN POSITION 2X 011/37' 1/2' I3/B• r VIEW ROTAIED I80" 331B' 3/16 23/3Y 4 I V3T I T 62 3T . +` OF BUP 2X O?nT fff 11 cl"r 4X 14' (21/4' (31/Y 3T I 3•a FRAMEOPEMNG WIDTH I C FRAME CPO lFNG1H i 4X IT I 1") 161/2' Is 11/ e 2X 09/32' IS--- 1 7/16'L 3/16 1 q ACK UP PLAT L'L OFBUP OR ALUMINU. WTSONLY +{3 TrT) (21/4') TYP S FRAME RODPD.A4MSPMOFARSL LOADS.V=MLOQHnHtr.E oK 01,11, DESCRO M eY DA1E THE BILCO COMPANY +»+ CrJ IMAar PAm l= "-N —C ti:W om �97F{SAt Iw P0X9/e ndAsom om�ercoflelwexn Au.oe ao we S/NB DOOR.ASSY B �S/NB DOOR ASSY �(J; SCALE 1:7 WEIGHT: St�T 4 OF 10 —(47 1/t) 4X 411/3r O O+ VIEW ROTATED 180' 1• 33/3• 23/3T 3/Ib 41 b" 427/32 .—• -- •— I^ 75 L ---^ 4 OF BUP 7� FRAME OPENING 4X 419pT WIDTH 4' B 37 FAAMEOPEN14G 3/16 1 IYP LENGTH 4x 14' T 1") OF BUP 33/4'T=� 4X T69l3T1S11B (21 — 21/{ � 1/2•) 393/B" 2X 3/16 13111 4XOW 227/3T-1 F 4 29/32' L.J L.•J CK UP PLAT FOR ALUMINUM NB FRAME 'NOS ONLY p de STFA i DNS' ay �DE STEFANO raoouctacvwrm �: A. �h•., O e+rcameewoaRovr.vc �ogr.�dir9h47. N061657 +momoenda.rGu. nr Pap.Om.m. A..toerrb //-4�12_/0 j*. 1. `,,L.� faYwY.Wsf.,.li� I:o:(W1,N/d11. 11.1GPE�� 7{ 7C � u/M00uu4roew:xu.NP<w STATE O�r' n,A/CJ1WI10oI.ftl/ n Ck 16318'—j Zxd IS/lti I SX I 1/S' SECTION E-E 163/g'� r SECiiON F-F S FLASHING E 19� 5x 11/16" 383/4• SWO_N c IdOFE DIMENSIONS) AREMEAS IPFD O FRAM THIS Ty ,r SFLLS Gt14G r7 A I G O T VI W FLASHING COMMON VIEWS 563)T r 283/8' Le. ex 1 US 2X615/16' � SECTION H-H E BILCO COMPANY esatw No�I1wm�Ctt,�Oc0.1Atl69C.1 /P deSTF sexes4io�aEeaTivoEANO S/NB DOOR ASSY No 6166? t*� ** a„»ouiwo,aaa a aw4++raara E(11,1: Cv1C.�.bpv6¢fwv[RMeeNO.� STATE OF SrrE-fS--- � calmonw�.ved.,nw.+w.wr ana S/NB DOOR ASSY'' X4 ONAI uuutwoearoaro. rs PIJ Ex1Hh I SM�15OF 1e n-�OeSnPaRO°a^^� r NB FLASHING racommmm r r,+e w A�Oi`w N PARALLEL rFR—AMEING O.C. I LJ a35PACE5 I75/16' .C.— y I TOHINGES 3JI6 I I/2 I OF AT NON HINGESIDE 3116 I1/2 ? FP.AMEOPENNGWIDTH � 4OP6" UiTRAMEOPf7RING— PENNG L��'11TH� I ® WELD DETAIL ANCHOR HOLES I ®NCHOP.HOIl:S/I6 SANCHOR LAYOUT NBANCHORLAYOUT STANDARD CAPPUSHING - BRCHP" BENDDOWN TAB 1" RIGID FIBERBOARD— 3/B'x i"HEX 3/f7'%17/B' INSULATION HDCAPSCREW ZINCPLAIED G SCREW W/ L/LOCKNU7 R W/31 FLAN TWASH 07/IB 3/4-FUI WASPER 21/4 2x6P7 ( � h-31R' Wx3'x 1/,r SIEELANGLE—' STANDARD IT CURB WOOD CURB STEEL CURB CONCRETE CURB w SGOVOlNAWC11DlDOPMARAISPPPK"EAP56lOAyiueal,walNNGE DK a7ian' ANCHORING OPTIONS @V. _ OLSCE�RON 6T OAiE _ — "a'°°°"� THE BILCO COMPANY aes uiunaavo ..,, rn cram,sia1°i�;r".ouusem ma mas Qg� ��Fqy �C)DE STEFANO .u' po,+m i.�ecoe• .m�er<eauato<w, �:'\' �.,.Q exovrefaWaaRavv w. rlloollcr�cvcs® ac,wosx co ^eau �n�Jlyal/l�PftdY 09.1G �a� iS/NB DOOR ASSY } No s7657 r6pl.•aM6lmtW.,rl mlrlamarl maser-P�drr 0 PA'�c�a�:im tt ,,L� svuallaw wa AuYPIrNbalro AawP�.Mr A ' �Wuaxo+a Ne ••— CA i"•' 7[ •i EYUL' Il�rla!`.M3�M3]M..Mbemn 'JM��/T an.rrel.oxcra. � STATE Of ey h v • i hrth•NdAWmvuDnlfumM ball B S/NB DOOR ASSY X4 iP�c3"•OR��P.\�� ra.a• SJ OVAL aaarl»aax m�orwueoa+c _ SCALE I9 EGii1; SHEET 6OF 10 , rt.x[canuroxParm , r 37 515 5 16 51 R:3 d.1/T) I NO'. sx 00 COVER END VIEW LINER 3/16 I iT1 /2 COVER 13/d' (NON-NWGEDSIDES) 31/T mwc� E ONLY] V 7/8 NOTE (---1611/IB�{811/3T r0In, 8X�9/3TT 35.) 1/2 305 AT3sJ8 51x 3/16V 1 51/4• BX 3/16 2 13 000 000 , I/H' d 1/tr' ' s vs A71 /t COVER SPACER LAYOUT �ER I SE092 M-M OR K OUG�ITING S COVER I MB. 4 wIll 1011"oll, ouc 0121111 —�T NB COVER ft If BILCO COMPANY r. m.lxi, Ncwaaenca.ra�w Duosde S TI R `6 _ ul law>s ro.rmiv»e•a nvnneemm o.i.Jeweo3mcozan YrorI ;.•\, $�•�O DE STEFANO ENawtFJmvoeRolV.]L rAOauefrr<YTt® _ '• wWYFbUs -CC77�� S/NB DOOR ASSY No61457 * * ieea).,o�ss..«ss.1n rn:wom.vl� d.rsa]Rvi4]1]]t FarA1„u10)1] Mai, Awy.wNo r- r� ,� STATE OF rwe.na .wauw.�.cn]cwro� biCYYrNAcAailu� A4:MI ]1N] B/ S/NB DOOR ASSY.............FLORIOP X4 ' ��a GNAT wryA�. ux�r ^°i CIE: I:7 YE1G}II: I SHEEl7CF 10 COVER END VIEW LIN3/16 1 in COVER 31s (NONFGNGED SIDES) 3 (HINGE OM INSIDE OF COV TO EDGE OF LINER AI _--UNIT PART NO. MATERIAL DLM'A" S it NO SDSOIA 14 GA .07 GALV "M 30' SOOOR SDSDSA i4GA. A7 UZI EEL 35" S 6 NB SDSO7A-AL 11 GA..040 3003 H14 ALUM 30' S-043OR SOSOSA-AL IIGA. 2 300:1HI4ALUM W N84MR SA913 14GA.1.07Si GALVSTEEL SP NO-0OOR _ S0513AL� 11 GA. DM 30M H14 ALUM FRAME NOTES: 1. MATERIAL MUST BE ABLE TO BEND I80' BACK UPON ITSELF WOHOUT FRACIORE AND FLATNESS CRITICAL DIAGONAL MEASUREMENT IS tlpT•. CORNERS MUST BE 90'. "v�de,ura+saaw: 1w wvp THE BILCO COMPANY ro.emlma r+..xw.r.ea.Kcmu onset �'" �aes / p rF,cq �DE STEFANO `m C•':O ENQWEERl1JO OROUP. PL aanµod ur i} Eji{!1L`rZseiOt S/NB DOOR ASSY No81657 .eww,.esmns"a1a maur•,n. •*e * * :•uurfm«a OA c.,or u«aorW.swanco•�...ryaa. w.eame msm.n.eas*...am�s* STATE OF � emak,no.e.mom,rnan«c+ ana aw �-� B SINS DOOR ASSY v�w�cOR�o?•�, X4 �`�S(Oi...... j vim, ncerrr,.o x n_uwsrwam+�nur SCALE IfJ EIGHT: SHEEf00F 10 icu,ocw.c UNIT PARTNO. MATERIAL ff.M'A' DIM'0' S•DOOR_ 3D505P 14 GA. 1.0751 GALVSTEEL 3211/16 347/IE S A NB SD5% 14 GA 1A751 GALV STEEL _ 32111W 34 7116' SLDB W506ALPI I I GA. 1.09M 3003 HI4 ALUM 3211/16" 347/16" S-DOOR S0506AL1 I I GA.(.OXn 3003 HI4 ALUM 3211/16' 347/1 G' S4=R SD507 14 GA. (.0751 GALV STEEL 3511/16' 4071IB S-DOOR SD507AL 11 GA, (.09D'(3003 HI4 ALUM 3811/16' 407/)C" N84=R SD524P 14 GA.(.075"1 GALV STEM 561I/16' 587/16' NB•DOOR SD524 14 GA. (.075) GALV STEEL. 5611116, 58 7/16" NB4)00R 30524PAL I I GA-(WM 3O03 HI 4 ALUM 5611116, 587116" NB -DOOR S0524AL 11 GA. (.09M 30M H14 ALUM 1 5611116' 58 7116' FLASHING .....,.... F , bho.Cam omm;tSCeDOBco.Ocm N.�1�t 6ESTEFANO__ .w C'..Q �fiDw� ENOINEFIIWG OROW, PL 1—m Oro RC S/NB DOOR ASSY c` No61657 ...".,'.,,./.,. '� )i SIr.WIla,kbN214 F�M.II..�.l70 .naeram>.v. STATE OF •'�4j ew ud4.mnoa.a.+mu nut 2UR10P: Iwu ru .n X4c 6 5/NB DOOR ASSY 1-7 arw•-- Rpm vruln SIOIdAL' ww .a4sraµ%F4 R.mm�nem.rF.ra. Gi04y6i F�L 4}.s.i 34 mi. r—31513r 315/32'— t 5!8' I (1( MATERIAL 1/lE I sff 011/32' I 1311E 01 I= MATERIAL 1311E 1/r MIN 15115- 11/3r �� SECTION Q-Q I . SECTION N-N `++AFL A SECTION P-P L MA78ML UNR PART NO. MATERIAL I UNR PARTNO:---- MATERIAL �I I UDH( PART HO. MATERIAL I UNR PARINO. MATERIAL S S0502 14 GA..07 GALV STEEL NB SD511 E 14 GA. (.0751 GALV STEEL STEEL S 50521 22 GA..0321 GALV STEEL NB SD512 22 GA. . GALV Sf(fL S 50502AL IIGA..O➢0.3003HI4 ALUM I NB SD583A I I GA..098T 3003 H14 ALUM S SD521AL 18GA.(. ' 3003H14ALUM r NB S05UAL 18 GA...14 ALUM S COVER _ _ NB COVER S LINER - _�. NB LINER �561/6'� L6^1� T{{��I--MATERIAL R 1 r �r �r3l15' ' I S Ill'1 R SECTION R-R 5/s —IMAL� UNIT PART NO. MATERIAL Na 1 14 GA. (.07ST GALV STEEL I 1. 114• NB S0527N&AL ELGA. (.r 13003 Hf.1 ALUM STIFFENER i ■r SCOMDEveN.notDOPENAwLWOMEes&LOAM LAMLt=Iuimte-j�mwnr 0114^ S-ZlSECTION SS eLv. ._..�_ 0arnrnoH� er OAtE SPACER IMF. BILCO COMPANY 'uv�.c.urm:swo- te..m ao „rum ,P,��apI,,,,m, ,b..,,w.P,ceP,t� .,, m:as p,,tdya�`sTFF• �DE S TTEFANO .��ItfllWen GMw'Al'GCOT O�iep�P9#YOCEiCO<4 Q' �t.C'YS•pp� • eq �\. �'�. p••. � El101kEEfaNO GROID;PL Ra000(� 1 .a ,Awn ta�PA c�c No6165J rata.raoesenr.ar.m m:nrarnnrN �Merep7a��rDeEtatb S/NB DOOR ASSY �k; * a�rr °ram • `..°,„' ;` A«ns / !o¢ • u / ucw a..ur.unoAnw vr— ,�; STATE OFrN�---^^an••�^.r^^• CP®uN SIAKAMnYN M..Se. trfn B S/NB DOOR ASSY X4 . 4t3;:20R 10Q: 9/0?lALE�' rueeAcetrrrno.re oo•mrrJurnnnwI SCAIF: 1.8 EIGHT: PHIET 1001 n.umnut aaenur UNII PARE NO. MATERIAL S&NU S035 13ALV SSiTEE�a-LI-1 90.1 C S & NS S034AL 11 GA. 3000 H14 ALWUM (.098'f Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Sample Warranty Main Office: 804 Old Dixie Highway ' Lake Park, FL '33403 • Tel: 561.223.2096 • Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused V WW W bz, 2 U, g R." g r INTEL11G.E -SEAIWAN CORPORAT10f�,CADMMR MCIAL W FING WARRAY.NT.. -ROOFM301UPONS :Building Name: SAMPLE Warranty Serial No.. ':,PqiI!d1ng Address: Effective Date* .............. Building owner,:-:'. k" Warranted Roof Area: Owner Address: Expiration Date: the described 770 -Owne0i " lbedabi�ve (the.�eullcllng") SEAMAN CORPORA N ("Seaman. Coip.�) warrants the owner above .. ..6f i subject to the Terms& Conditions set forth: below, for a period of 20 years commencing with the date of substantial compjoilbn of the installation of the -roofing membrane, Seaman ;Corp. Will repair leaks originating in the FiberMte Roofing System('Roofinq.;Sy'item") Installecl..on' :b6ilding that are a n authorized Corp. to. Install thpJR96110 System� (an attributable to the Roofing ang/cirworkmanship provided by a, roofing applicator I:Icir zed by Seaman -Adth r Applicator") "Authorized A Terms & Conditions ':I.:.The Roofing System Includes only Fiber-Tite@ roof,.memoranes, Insulation and accessories -provided by S6aman Corp Installed 16 Accordance with must.. d:A pliqator 'inspected6nd�approv6g.15 Seaman Corp.'s technical SpOlOptions. : ' ' :i. in order forlfils� warranty to _6ie R.cifl6g� System �d biy-an.-Authorize 6_ .be effdc,tbv��. have been Install 'p warranty by - n Corp. 3: Owner shpll, . g I I vd.Seama6-:Cciip. written.notice notmore . than th . Irty'(30) days:After. disco Very of any leaks In the Roofing System;.`,Oy giving such SetaTqn,Cor,, I inspect the Roofing sysl:6m;ind.I6V6tIgat6 the cause of the Ida hotice.Owner authorizes p. or Its Agents tq.jp! Ic '4-Owner shajj.giye-cir.caui6 co�be�grant�d,toSeaman,Cbi�p.:'fre6'.accesg to. the roof during regularbusiness hours to Ingpectt - he.access '- -Roofing . 4-Owner ..1. ., .1-11...... .. - . . .. ....: 11- .. ..A _. . . &-' delays "System. ','Owner.: shall Inderh6itj and.6fd5dainan Corp.tharmless fdra;ik.....irpage$.or-costs;.'�:cu!.., as a i6i k;of sie cid 6 -ikridicins. th6ijid the kciojhh*Usystem be"concealed With 'an overburden; i.e., garden roof, paying etc., Owner irlty�dr other i :shall be r4sponiltile':for all c6iti;necessaiii6:expose the Roofing sy'siiiii,eor inspection and/or repair rp. �cleterrnlnes.jq,g. ,;after. ts.i9spe - 1 ' �6d fifth th6i 66.1 area result q . ...... S.� It ' I inspection, 86 .i�Snbo 'yilll'i6o -anyl6aksln fipg- Systerp at Its expense, a the Rqo,i� provided by.the Corp. A64 lisl6iij.eition, S6a*marr'Cd'rp �ae*ti!ribines lk-good Mith.that the -'Ciusd'bf.the leaks -.ifd-i)6tside 6F'the sc6i�6`4`&swarranty;; ...'sh the leaks and for Seaman of 1he type of repairs necessary o cc P . tcirp'I, irivestigat on�and Ins0idtibri costs an cause the then existing rgrnAln6 portion of this warranty :to remain effective;This warranty shall automatically terminake1f owneifildsio proml:itiy make or cause to. be ri�iaclia aj�j;i6ch repairs -or. fails to �pi�.Such Investigation anflnipictioh'costs, h such . ch ., system without. n no'event I-- dons brid'pli6irs to h mng,systc4n4dilnitiil filxturps.ori'prthrough 7"! pil. Owner �rrjp� q.�!qy %A Ora 90 ifie'prior written consent of Seaman Corp: i3 Seaman do 'h6vei"fi-`o''' �o-bli'gitioin-,o'Under 'this... 'm-pi.rrAp. *ty _4n* ip.,s"s., iand until -...A.l. 11 invoices .. for- r otherwise --re ating .M: A_M'. ',. Rocfng ' S'y�s�tem, including vAt4out llmltatlon,:sandsupplies have16eefpaid. in ,119theAuthorized Applicator andSeamapCorp.. war 6thall not 69.60IlLabe to boishall Seq0a#:Cqrpb ,os4�tdupedjq whole or In pprby.'a udIn0:mithoutImita66, earthquakes, hurricanes, 46614 of than 1441n.jhAanb te ' or whi0Impairs `,the :Roofing ,Alsobe ience,vandalisrh;'anImaIsj or insects amage'the"Rbo ng System, which the Roo ng'SystLrsa ty'b unauthorized iiWitions of ifie-Rocfng tyiiin (see Seition 7 above)crinstallati6rqf struci6r6§,ifxtures,:oritilitles on-8i-through the Roofing S yste-m .,;bykbwher,(d) negligence 6i4a11ure of Owrer*to.propprIy.VmaIn6lnthei0qofiqg.SysteM;Aibudin441lthouill itation,failure o Qw66Kto.nblntaln the e accordance with �eanan:Corps Plb6eTiteM61nt�nihc�Guldillops;lipted,qo: jreyqrs@'Pf h defdttlye cohdltion,'�dpter'Oof t bstrccture or su6Atrato towhich ithe. Roofing System ls;attaqhqoorth6.vialls.br.m6ft *"..,! X� f :.(fyal� chihikal�&hlbmlnants' rjuriousAo the Ro.o ng ystem,Ahat h'a've.,.nor_beqn '�p'qc_cq y approVqjq;y Seaman via e idilalsSubmittal & War46iyA4equest:,166n, (g) 6affc"o storage.o MateripIs09Tthe R6ur�6��y�temi(h),�hfiltati6n.6�.�bhdensad6nbf.moistureIn, thf66gh, around. crabove."&walls 66djor other .a64ard.bf,the B4ildIng,.(1)acts o party than Seamaq PO. fi i ":And/pr:(J) building 'or.its : theSuIlding; ,y.-..ofthe euHding envelope. 10 Rights under this hls.warrany:mayb61earsf&6bIe bib"rer to a third :pary i the lttbn..co�hi6n t'df .0e-then-current transfer fed,-iinspections services and subsequent rdpiiiior the 116066 Syst66'i;;If'iiecessary,.�.6.y,the owner. =Tallure'by` Seaman Corp.,-Ao AiR h or conditions In this not be Inter d to%iiia a waivers4'�any. terms and condtttoris f?jce ypy:of.t. the p - �e - te 'd bI ti 11'6e.dee6ied iefdrmed�br-delete but ty" hy�,Oprtlon'61` Ihls� W; P 's j1�r:warrinjy.... deleted; amended warranty. cirrarifyIs dinerifbr�e6ble under e pottl n- a law, of this 'only to the :MAY be o `b Ihid.�bya.Uihori*i6d�i-Ooj;Llk�fit�tiveso both nly: Y a wrItjh§;,tj! f h parties. . ..... .. . ..... Iconflict o law %12.'-This warrantyshail 66i666iti6ed in wlth�-and shzilFld governed bi,4he laws State of.0 Ohio without priAlples and Own'�t agreqs.�o:submlt to"th"e:exclusly'e'�jtl�i�diction'60 the, appropqiiiq-.state. ori6clerai court ,.'within - Suriirfilt d6rity, 6616 ��or purpose of n Owner de - ' . : '. ` � -'� .�i , , *.. connection PT CORP �I�P.a6 or.. I cp resolving ty �0 SEAMAN E E :WARRANTIES It0 M.,WHETHER H )NRITTEN OR ORAL; EXPRESS OR IMPLIED INCLUDING ANY E _GU A R R A PARTICULAR TIMU OU�po� EMPLOYEE m L e R UPRE AR R E�N 0 . p y 0 INTELLIGENT ROOFING SOLUTIONS ROOF MA INTENA,NICE TO: Building Owner —Attention: Building Engineering and/or Maintenance Department FiberTite Single -ply manufactured membrane ("FiberTite Roof') consists of a puncture and abrasion resistant fabric with our proprietary Ketone Ethylene Ester (KEE) coating that can withstand weathering and environmental hazards, in ac- cordance with the warranty set forth on the reverse side (the "Warranty"). To obtain optimum performance from your FiberTite Roof and in order to maintain the effectiveness of the Warranty over the lifetime of the Warranty, you must comply with all of the maintenance activities set forth below. You must perform bi-annual inspections of your building roof in the spring and fall of the year, as well as immediately following any significant weather events, to make sure that your building roof is free of any conditions that may cause unnecessary injury to the roof deck, leading to expensive repairs and possible damage to the building interior. When performing a roof -maintenance inspection you must check for punctures in the membrane sheet; open seams at the membrane overlaps and at the roof penetrations (soil stacks, curbs, platforms, etc.) as well as the parapet walls and/or edge details (use a blunt instrument, such as a screw driver, to inspect seam integrity); caulking at the termination bars, surface mounted reglet and pitch pan sealants, any loose fasteners and nails, both on the roof field itself as well as on the wall and edge details; check drains and gutters to make sure that they are unclogged; and check to make sure that there is no water ponding on the roof. -We have included a checklist to be used as a reference tool in performing such inspections. You must also establish and maintain a policy of keeping unauthorized -people off your roof and minimize the number of service personnel trips on your roof. You must place locks on all doors leading to your roof as well as post a sign that disallows entrance to unauthorized personnel. We have enclosed pressure sensitive labels with your Warranty that you must post on your roof exit doors. These labels refer to the slippery nature of the FiberTite Roof when it becomes wet from rain, snow, or ice conditions. Proper safety shoes must be worn if it is imperative that roof top work be performed under these weather conditions. If you have a busy roof, i.e., one with much foot traffic, you must install walkways on the roof. Use of walkways will minimize the possibility of damage to the FiberTite Roof. It is important to consider the roof covering whenever you add new products and/or processes to your building operation that.will cause chemical contaminant venting onto your roof. Below is a list of chemicals that can cause harm to the FiberTite roof covering,especially if left ponding for several months (please note that the list of chemicals below is not an exhaustive list): Acetic Acid Aromatic Hydrocarbons Asphalt Materials Benzene Cltlorox Cooking Oil above t40'F. Ethyl Acetate Furfural Gasoline Methyl Ethyl Ketone (MEK) Nitric Acid Paint Thinners Phenol Phosphoric Acid 75% Plrthalate Plasticizer Above 100°F. Solvent Degreasers Toluene Xylene You must consider the compatibility of the roof system should the building be used for a new purpose. Any installation of new roof top equipment, such as air conditioning equipment, requires the service of an authorized FiberTite contractor to install new flashings and other equipment so that no harm is caused to the integrity of the roof covering. In addition to the bi-annual inspections referenced above, we recommend that you initiate a service contract with an au- tborized FiberTite contractor which allows for professional annual inspections and immediate corrective action for any potential roof damaging problems. Authorized FiberTite contractors have thorough knowledge of FiberTite roof top tech- nology and full service professional abilities in solving roof damaging problems. Contact your FiberTite representative or the FiberTite Technical Service Department for any assistance in locating these authorized contractors or for any ques- tions about your FiberTite Roof. Seaman Corporation: 1000 Venture Blvd. Illooster, Ohio 44691 teL 8001927:85-78 fax 8001649-2737 trivic. tbertite.com w►, w seantaucorp cons FiberTite® is a registered trademark- of Seaman Corporation FC-A Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve ,1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Material Product Data Sheets Main Office: 804 Old Dixie Highway * Lake Park, FL 33403 ■ Tel: 561.223.2096 • Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused M-Value polyisocyanurate roof insulation consists of polyiso foam core A ith superior fire performance characteristics and the ability to retain its high R-values over time. FTR-Value polyisocyanurate roof insulation is manufactured to meet and/or exceed Federal Specifications: ASTM C1289-11 Type II, Class I, Grade 2. FTR-VALUEis offered in a variety of thicknesses for single, multi - layer and tapered installations. The closed -cell polyiso foam care is integrally laminated to fiber reinforced or fiberglass.facers. The composition of FfR-VALUE provides an excellent substrate for mechanically attached and adhered FberTite Roofing Systems. FTR-VALUEis available in 4' x 4' or 4' x 8' boards and has a long- term thermal resistance (LTTR) of approximately 6,0 per inch. Underwriters Laboratories and FM -Global have classified/ approved FTR-VAGUE, as a component of our FberTite Roofing Systems(s), respectively as Class A (UL 790) and Class 1A (FM 4470). FTR-VALUE is also accepted by building code jurisdictions. See Seaman Corporation Guide Specification (GS 04/08) and Addendums as well as Seaman Corporation/FiberTite Material Safety Data Sheets (MSDS) for additional and specific application, design parameters and material precautions. Use proper handling and storage methods for FTR-Value insulation, keeping it dry at all times.Tightly butt all roof insulation board edges and stager adjacent joints. Install.no more insulation than can be effectively covered/completed during the same day. Except for loose laid/ballast applications, FTR-Value roof insulation must be secured to the roof deck. Approved securement methods include mechanical attachment using FiR •fasteners and insulation stress plates appropriate for the deck type. Alternatively, FTR-Value roof insulation may be attached with FTR-601 adhesive, hot asphalt or other approved adhesives appropriate to the deck type. For adhered insulation attachment, insulation boards shall not exceed 4ft x 4ft. 5�OlmerlslSfafir saw r t 3� 5� F Few �1 f�"•r..,ra.m; Fx.....v,E..'''".s-.Y'12'fia...?v,- _:.- W 4 ,ASTPo�,D21�B�+s Compressive Strength ASTM�D16 g1i J� .ate l�aleiAf r ,},,, '�'.v j:�x.i�`. i i ASTMG2094 i'M-Miyvo(tgn�t Mobblie4aporTmnamissian $YnldOetD&1siSY* � ?3x try" z �' -� ''•�� Mn a �� Flame Spread �84 502 t ess± �i$mb1(e �r,,,�,,,,,..��,,,�� .'23 6 P a5 �..Z,}czy.. - S a. .,4 .�,�"'fiY., =? CI GY£t Ji'f'w .,,1'3 .A > „` 4�'.`s _'_"^1.`..�i �..?i L � .%"E u (e "FrR-VALUEis also available In 25 psi compressive strength (Grade 3) xifacktiess s s y LTTN per ASTM Ca289rjt �° r f ute 6pari Rip_ 1.00' (25 mml 5.60 2 5/8" gq 4 -k� Si+•5T" -gr^ _f +m" .:K` S+ 'SAS g - 1.60"(41 mm) 9.10 4 3/8" 774 t.80' (46 mm) 10.20 4 3/8" [��'s+"�t5r i�'`2.09 51fifn=� {fix �`,_.r �r �.•' ,�N.-:..,a�rc�-a �c ,���'G. �,, �s^ ehkkr 1'rv, '�.'i'i 2.50' (64 mm) 14.40 4 3/8" (a ,;70 (69rnm)r fia;@ 3.00" (76 mm) 17.40 4 3/8" 3.30' (84 mm) 19.20 4 3/8" 3.60' (9) mm) 21.10 4 3/8" `n iq 'OR'2 '»4'3)8`" �`'�i':•R SM 4.00' (102 mm) 23.60 4 3/8" For more information on FberTite Syslems 'Lon0 Tenn Thermal Resistance Foam Care Values are Lq 1b andaecosso des please cau: based OnAST1dC1289.11. �NtlLRJ� n Seaman Corporation (800) 927-8578 _ lntemational (330) 262-1111 w rWAd dite.com INTELLIGENT ROOFING $OIUfIONS FberTite" Is a registered trademark of Seaman Corporation. fhtOSubject to the condtiorc mnpprmaJ for a roof comiiV �� ����® when i idled as d=bed in the ciarent cdkn of the krW00 Approval Me. �i @ ASSOCIATION. INC. cV "e k Wan eilaN five cmrreatti. See ULCRUtDryd con 05 and slsrerrsms Wdery 7�sla-4VO,SIM. male als .�1 ewuaoaneeourm SPI7I ESR•1456 FiberTite Insulation Fasteners and Stress Plates are designed and engineered to provide enhanced load distribution for -the attachment of insulation and cover -board. FiberTite Insulation Fasteners are engineered to secure approved insulation and cover -boards to steel, wood and concrete roof decks. FiberTite Insulation Fasteners have a heavy shank and deep thread diameter to provide high withdrawal resistance. The fasteners also include a deep #3 recess for ultimate bit engagement, a reduced drill point for quick cutting of steel and wood decks and a high quality E-coating for protection against corrosion. FiberTite Insulation Stress Plates are available in either steel or plastic. FiberTite 3-in round steel insulation plates are finished with AZ50 galvalume and have a flat(flush profile for use on rigid board surfaces. FiberTite 3-in round "Sand -Dollar" insulation stress plates are manufactured from high impact resistant polypropylene, have a flat bottom profile and are designed to lock the FiberTite Insulation Fastener head into the plate. All FiberTite Insulation Fasteners and Stress Plates exceed FM Global (FMG 4470) requirements for corrosion resistance and are FMG Approved for insulation and cover -board attachment in Class 1 Mechanically Fastened or Adhered FiberTite Roofing Systems. FiberTite insulation Fasteners and Stress Plates are designed and used for the preliminary attachment of rigid insulation and cover - boards in mechanically fastened FiberTite Roofing Systems and for principle insulation and cover -board attachment in FiberTite Adhered Roofing Systems. "ham C.y4 R i `R J' $ s .����_ x.., Drive shllllp5.^..�'i� rea rkm S ��ar t}238irt tiiy Shank Diameter Feint Type Withdrawal Load 4N 3r p((�{2,45�Cg��22�yaeef�� For fastener and stress plate placement, installation instructions, frequency and their correlation to specific approvals for wind resistance, consult the most current version of Seaman For more information on FiberTite Systems rlbErAfla and accessories please tail:Corporation's Guide Specifications for the Installation of FiberTite Seaman Corporation (800) 927-8578 Roofing Systems. International (330) 202.1111 ww w1bertile.com INTELLIGENT ROOFING SOLUflM Fiberrd& is a registered trademark of Seaman Corporation. roofCONering when In Fltstalledosdoscribed AMID in the current edition of the Approval GUWe. 0 C 9IFFAA5�90�CILAir IO�fI. N� %%/ �PR Seaman Corporation's 45 mil Fiber'Pite-SM features an i8 x xg / 840 x i,000 denier weft reinforced polyester knit fabric, coated with a proprietary compound, utilizing DuPont'sT11 Elv-aloy'y Ketone Ethylene Ester (KEE) as the principle polymer in the hybrid «mil alloy coating. 45 mil FberTite-SM is a 40-oz sq. ydlnominal 45-mil (1.1 mm) thick membrane. 45 mil Rbefflde-SM not only meets or exceeds the minimum physical property requirements enumerated in ASTM D6754-02 Standard Specification for Ketone Ethylene Ester (KEE) Based Sheet Roofing, but exceeds the physical properties and performance characteristics of 60-mil competitive products. Seaman Corporation is vertically integrated, which allows complete control over the manufacturing process from the selection of the yams, to the engineering, knitting and weaving of the base fabrics to the final coating process. Today, RberTde Roofing Membranes are the result of Seaman Corporation's 60 years of applied fabric engineering and coating technology. All FberTite Roofing Membranes are constructed using high tenacity/heavy weight yams to create a base fabric reinforcement to impart superior puncture, tensile and tear resistance properties. The base polyester fabrics are primed with a unique and proprietary adhesive coat that lays the foundation to physically bond the KEE coatings to the 'fiber" to maximize seam strength and overall membrane performance. 45 mil FiberTde-SM is coated on the face with Seaman Corporation's original "KEE" formulation to provide superior hot air welding characteristics, extreme UV resistance, broad chemical resistance and long-term flexibility and reparabilityfar the installed roofing membrane system. The back side of the membrane is coated with a slightly modified (SM) economical version of Seaman Corporation's original KEE compound to control membrane costs while offering additional thickness and weather ability. Additionally, 45 mil FberTite-SM exhibits excellenttear, puncture, fungus, algae and flame resistance that make RberTite Roofing Systems some of the most sustainable roofing systems available. 45 mil RberTite-SM membrane is manufactured in conventional, 74-in and 100-in wide by 100-ft roll goods. 45 mil FberTde- SM is also available in customized prefabricated roll widths and lengths that incorporate integrated fastening tabs, sealing tabs and also "no -tab" rolls of membrane up to 20-ftwide by 100-ft in length. Feld seaming of the membrane is accomplished by fusing the thermoplastic membrane with conventional hot air welding equipment yf T�R�1'C%�kt1aS3 �2f} h b I Yy _' 0 79 (9 034J yi10045iM s Thickness over Fiber, ram (in),�01�46 -A OPBplme(Irod(lndiesJ s X 3i I BI�aNngS(re49N1 Nhtlx.w ors xk�a,hT5 QTf' ..y_ �28Ji Eb lion at freak % �N gz OIN Y k* AST1A0751-rst6pj 'i�"'r5�.�`> s°' (Mb ASl?tATy6r7CngTeat.z hs�`XWO i 3t�5 unearDimermanalchange z:� 13M 0ow ASTM D 1204 ma (95J tt h ?� 7 W Pe Retention of Properties alter Heat Aging AM 0 3045- 1761156 days ,{t" il 'a Breaking Strength, strip, °! original' A BOr � is 'f BD M Etorlgagon at Break, strip, %odglrntl ��t,'��G9D ,,�r:...�Y.r.a+�J'�^�°„ �' Low Temperature Bend r � 30 W, Lh m r ASTAID2136ro g f KT En -4r Yo4fa'rn S s ? i{r r aCt)angolntl�taftetE�(pusurelnlNatEt �c a !' y.a'- 1 0 6tl x,rwx^ .A//��,, 3? ` � lA v."' _! factory Seam Strength, N (Ibg `r1780+(4Ob)`1r' FebricBreStic�', 5. ASTAf D 751 Grab Afetho0 n c y ti �n.hTc t�11"'p"k�.. < ._ �' _`a,.N ar.s . '�_., , i.�'. r .:1v 1'#r'•-�.3„-`,'u�' bk .i.. `i�wr :4f - `14 Slalic Puncture Resistance > it3ass s€r,r F ASTMD5602(9916q , .'a.r? 0 CPrmctureri(es{sta� 1 `a,,Xut_ fi t 'L {' ' fir +�1111 ,,,l r - 011 tl y k , r� r� y£x{ rx y't"a I k r+�s'S 3.i 1 NUN �i h NA h "r For more informlion on FberTite Systems and accessories please call: Seaman Corporation (800) 927.8578 ribella. International (330) 262-1111 t www.fiberlite.com INTELLIGENT ROOFING SOLInIOPIS FibarrfleP is a registered trademark of Seaman Corponalton. Frit &Mectlo emcar0oudAppv+al bra molca+ering Vw GWalIOC as de rbed Irl thawaelt editionof the t?� � Astoanexter"'Ifaobmweedy.&egLdiroctmycI s!fQ=drcactmy3714,4aP6.97P9�malerieLs CR C �A 'vimASSOCIATION. INC. � eS10.rtl 41ef WVNTI Haim ar 45 mil FiberTite-SM Roofing Systems carry extensive FM Global and Underwriters Laboratories approvals. 45 mil FiberTite-SM Roofing Systems can be installed by mechanically fastening the membrane with FiberTite Magnum Fasteners and Stress Plates or adhering the membrane in FTR 190e bonding adhesive or FTR 490 bonding adhesive to pre -approved substrates. 45 mil FiberTite-SM can also be installed in typical ballast configurations using conventional stone or paver ballast. For specific installation recommendations and requirements, please consult the most currentversions of Seaman Corporation's Guide Specifications for the Installation of Fiberlite Roofing Systems. �Tr "FA`- N"�•yi`^- �' P ✓J^ +1� 3"4P �yR ��j[ .�.: z� ,�Ce��.mtW'.'iBanlP�r{(�'�t. y5 If'� ��u+•j� � Ri � % 3-i t`SS C'/ri3+n.�-. 5N �54 J�{i( i -� ,.rT Xry.S�A�.`4 .� 4 � �"i'iyVW�':� R ,: r., �.� �� ��.� � �.w.,� �� Win. , � � _ �5 --•��� _. ��- � � �, craddrg(7xmagnification) �.:7',a,, B da9niR•`eaOn E �- . •^7 s i. '""�f}' x'Fg2w; `�.3' 'h. ^•6�'-'=n tiais.r`�+„^g{ Srn"n none A� �, r �e sfi v N, 1 c� AcceteratedWeathedngjp8 T PraWce 6 1541WA �. � G�_« M CIO" � . � � �3 ""+i. 1,21 �.� Yaa.'-•t73w��. a.. ��n° ,r tits. crazing (7xmagnification) !.G ��-i':.' I'Y .g%/ �i,d,SiB_0`�1�Cd1 '� 3-'f-a}�� .+'� . 620. WG B L'U W�Id"Y 1,11,. S s,LtG .Uo. �..s rim' Y+ 1 + .2 AbraslonTest,cles 6ee1/1,000gloadZW 03369H-18 �. Tensile Strength (pso 8500 ASR1 = -� S• r r --r.y Bre9king5trer�thi65E rT `4'V F "i` �AS1Mb751'83bAtafAorl```7„v^a „a` r �..,. ,s"f .�--ter' Avg fi?14NO "` . g P=WreResistance ms) 350 ASTM 0751, BursEng Streap +"irt. ..s.• MF�/ id may., ^rrc�2-�.i.r` alCry�a §�RiyF,,,f Xs-✓" "r �.`Yr'. 5 h4Td1E9BpMINN ), Shore A tiardness 87 ASTU 02240 J+�. S IYG' Jbi-. F`§�'+N'4 r b -a �v'P i t Yt .y Yss- #F .f! SSA' Yy�'y rt aj r �', IAlLD20G46CIt5Re0C1a?s1 t t 3 ¢zrar� 2z .u.k ru '✓,ri 13 Oil Resistance, TAIL-C 20696C none Ab sweling, cracklag or leaking [''1�aazi+etLK�ang,�17 r'r _r 9 y ,� a i3.. .sbx�r'_� is >�.•vE:'.._� -"Wt.,4rk ... ��- HighTemperaWre Dead Load pass ASTMD751(501as, 160'F fts) wpai SolarRe9eclance ASTME903 79% ASTME1918 83% 1�;Solar Ref{eeta 13Y� 19ed) {�'� z E z a�,i�x c�.�� Una j`�c '�,'wsa+!�789r5 #i•1L''.ThiC,.t,�,.sm.„��i i:�SMr'�sr,�`,; 4 SolarEmmtttance ASTME408 95% ASIMC1371 85% E SQtart�rtmfriallce( yTagedj tg"' .a,G4 y U GIe ried � Gteon 0 ia S `r� ..�Sxu..ry +'22..'e, ��+T. _ �� •A.vs r<...5"'� 'Pwk 4. u+Q.+. �.� {x„i,C �y�+`. ...5'.-`�'w^-'r'T3.�UiV`2.+.F,..?•fim,fb ?Y ;v Energy Star yes yr �-a.Tilt, r a e� fix✓��> Fc T' LEED 22 - Heat Island Effect 1 Credit SSCredil7.2 FiberTite Magnum Fasteners and Stress Plates are designed and engineered to pro -Ode enhanced load distribution and superior wind resistance for all mechanically attached FiberTite Roofing Systems. FiberTite Magnum Fasteners provide superior withdrawal and back -out resistance. FTR Magnum Fasteners incorporate a reduced diameter drill point for exceptional drilling, buttress threads for increased back -out torque and a high performance epoxy E-coat for superior corrosion resistance. FiberTite Magnum Stress Plates are manufactured from 18 gauge (1.11 mm thick) AZ 50 Galvalume coated steel, are rectangular in shape; 2.5 in x 1.5 in (6.35 cm x 3.81 cm) with three-quarter inch (1.9 cm) radial comers, a 0.25 in (0.635 cm) hole in the center of the plate, a raised reinforcement area to resist deflection and eight (8) barbs to enhance wind resistance. FiberTite Magnum-R Stress Plates are manufactured from 0.038 in (0.96 mm) thickAZ 50 Galvalume coated steel and round 2.374 in (6.0 cm) in diameter and have a 0.261 in (0.663 cm) diameter hole in the center. FTR Magnum-R Plates are also configured with a raised reinforcement area for added deflection resistance and incorporate six (6) barbs in their design to provide enhanced wind resistance. FTR Magnum-R Plates may be purchased as loose plates in buckets, or pre -assembled with FTR Magnum Fasteners. All FiberTite Magnum Series Fasteners and Stress Plates exceed FM Global (FMG 4470) requirements for corrosion resistance and are FMG Approved for Class 1 Mechanically Attached FiberTite Roofing Systems. NO NMI FiberTite Magnum Stress Plates are principally engineered for use in high wind resistant mechanically attached roofing systems that incorporate 56-in wide membrane and/or Top-Sider/closed lap assemblies. For wider FiberTite membranes, FiberTite Magnum-R Stress Plates are appropriate for wind resistant assemblies up to 60 psf (1-120). For fastener and stress plate placement, installation instructions, and frequency and their correlation to specific approvals for wind resistance, consult the most current versions Seaman Corporation's Guide Specifications for the installation of FiberTite Roofing Systems. Hateraly fir �a¢s `sase 7 t ryg hard rt0c1 o&rhon stet Nn Drivep�tnps�tz $aS. 'G 9h^.df"Fu'@ reaaDimttetar � x ` 1. -L.`aYrr lye 7 %v�Y'9^"�ya3.4ry s? � ONE ozss Shank Diameter t z04lrtt06tarl)�� a "1^r_. FrC`i.i�+c :'c .�` r a� x� ?F Withdrawal Lead* 'in 22 Ga. (0.91 thick) Grade 80 Steel as For more information on FiberTite Systems ssc lease man acc0 poraP2628tm927-8578 Internatio-1111 mvmfibertitexom INTELLIGENT ROOFING SoWRONS FiberTite'° is a registered trademark of Seaman Corporation. ®® Subject to the condtions of Approval fora �� �YIEF ill -_. LM fill roof covering when installed as descdbed CQ C aaat�C A,,ON. INC. A WAD In tho current edition of the Approval Gulde.EF ASSOCIATION, INC. °"' S R FfR im is a general purpose, one component, extremely elastic, moisture curing polyether sealant. It typically requires no priming to bond. to many materials including FiberTite, metal, masonry, concrete, xvood and fluoropolyiner coatings. FTR 101 is designed for use with FiberTite membranes in conjunction with terminations, drain seals and metal flashing. It exhibits excellent resistance to weather, stress, movement, water and many environmental chemicals while maintaining adhesion, cohesion and elasticity. Seaman Corporation supplies FiberTite FTR 101 in cases of twelve (12) standard 10 fl. oz. (.33 liter) cartridges. See Seaman Corporation Guide Specification (GS 04/08) and Addendums as well as Seaman Corporation/ lberTite Material Safety Data Sheets (MSDS) for additional and specific application, design parameters and material precautions. FTR 101 is an easy flowing, moisture cure polyether sealant, applied with an industrial caulking gun and produces a flexible joint/seal with good adhesion to a variety of construction surfaces including sheet metal, masonry, aluminum, brick, wood and concrete. Surfaces to receive FTR 101 must be structurally sound, dry, clean, free of dirt, moisture, loose particles, oil, grease, asphalt, paint, wax, rust, waterproofing or curing and parting compounds. In cool weather, store cartridges at room temperatures for at least 24 hours before using. Caution: Avoid prolonged contact with skin. Uncured adhesive irritates eyes. In case of contact with eyes, immediately flush with water. Cali a physician. Please refer to the MSDS for First Aid information. Most current MSDS can be found at www.fibertite.com. KEEP OUT OF REACH OF CHILDREN Shelf Life: One year from date of manufacture when stored in normal environments. High temperature and high relative humidity may significantly reduce shelf fife. Storage: Store original, unopened cartridges in a cool, dry area. Protect cartridges from water, heat and direct sunlight. Elevated temperatures will reduce shelf life. FTR 101 will not freeze. Clean -Up: Wet sealant can be removed using a solvent such as alcohol. Cured FTR 101 can be removed by abrading or scraping the substrate. ��9i1����k'"��'�.hl ��'i f= �at`h �Z �i{�i�' yWi�, vV�. �£'�� tf `x.,'e F }•,Q� �h'^�4=�:�'S ..�d�._Y�.i-Cx• <�f,+z.,��''�:?h .ice, �Er x'..t„� � . -r . ': ..���x`.t �.'.�i�se &""ii.; . ,..�����3�'F'y4,. �'"ti�3 VsiAl s k,; r`MWIRU�n,Y��etg�lGFa�e�`�`aI MIA, i !gg `9"Pr' 6 +' vori r OWNe ' it '?++e�+�. M r I y " #�� *r � s!� by Rto a spr)atcaW' nlcy .���+r��� open/cure Time `� U z 5JslnsvNwk 7&-`hV`FuB+W 1' .�}'�.. Y.H.utt ."`aF.a .ni.';• YY±W�'.��.;! ?Lk R, l ✓td f.; �r1 R 'i� a �' f��,'�^��1�`�"- ���"in�'riM-a"'� l�Ny'�iY•F•�e� RIN.i=;.le.�iG' :.��ev4.dcD-�3........ i-..w S[arage x� �'tl-9P�d�hr�`�vMd�ge/aW8!ir arfa �� Tensile Strength �iOA fdf125S �U,....,sX�s...�x z�.§+i•/�''���,�.rc. x'L%.�`.s'c ,x `k,�.. �:� �z '�'r"s'2 33 n�K`�t�a„ Working Temp. Range z�tol.«d�3'x 0 100% solids content. Does not contain any solvent. o Cannot shrink • Odor free 0 30 minute skin time at 70 F. a Paintable in 24 hours o +/- 50% joint movement o Non -slump o Bonds well to KEE membrane 0 1 year shelf life o Easy to gun and tool e Will not stain limestone wall panels or copings o Service temperature -40 F— 200 F o Won't outgas on damp surfaces o Shear strength 150 psi o Bonds to Kynar coated metal o Elongation > 700% _ For more information on FberTito Systems r� and accessories please tail: sob a Il it Soo acc Corporation (800) 927-8578 International (330) 262-1111 www.tibertite.com INTELLIGENT R�DO�FING S0111r10N5 FberTde° is a registered trademark of Soaman Corporation. 00 4.r IF aaxurs�xsavua L+ a soctn�e ilo. INC.a7 J .FIR Igoe is a IoAv VOC solvent borne contact adhesive, designed for bonding non -fleece back FiberTite membranes to pre -approved horizontal and vertical surfaces. FTR 190e is compliant with all air quality districts in the state of California and other regulated areas in the USA, making it the most environmentally friendly "solvent" borne adhesive available. FTR 190e is a Nitrile/PVC polymeric adhesive. The adhesive is quick drying but has an extended "open -time" so proper planning, placement and care to insure appropriate adhesion, especially during periods of high humidity, is necessary. FTR 190e is listed/approved for use with specific FiberTite Roofing Systems by FM -Global and Underwriters Laboratories. .A See Seaman Corporation' Guide Specification (GS 04/08) and Addendums as well as Seaman Corporation/FiberTite Material Safety Data Sheets (MSDS) for additional and specific application, design parameters and material precautions. Surfaces/substrate must be clean, dry and free of dirt, oil, grease or similar contaminates that could interfere with the bonding process. Compatible substrates include: masonry, wood and metal for flashing applications as well as pre -approved polyisocyanurate insulation, approved gypsum based cover -boards and approved base sheets for horizontal roofing applications. FTR 190e can be applied by either rolling or spraying at a coverage of approximately 50 ft2 net per gallon (1.2 m2/ liter), 45 T per 1/2 gallon to the substrate (1.1 mz/ 1/2 liter), 55 ft'- per 1/2 gallon (1.3 m2/1/2 liter) to the membrane. Actual coverage depends upon the porosity and smoothness of the surface to be bonded. To ensure proper application and curing of. the adhesive, the outside air temperature must be 40` F (4.4eC) and rising. Spray or roll a smooth, even coat of adhesive over the exposed, pre -positioned bottom of the FiberTite membrane and a mirrored symmetrical area of the substrate, insuring 100% coverage. Allow the solvents in the adhesive to dissipate to the point that the adhesive is "sticky" but not stringy to the touch. When sufficiently cured/dry, carefully maneuver the glued portion of the FiberTite membrane onto the glued substrate. g ..A�11be�,rt'y- viscosity s ay � uYs Coverage x s ;'S0�/g81�3�,�rtzj�a�:Ybcatl'su(�e �".4.. � -y�_trlj[5� x �U�t1T�riComplat9f1� m n5 rt6Qti rt SD WIN �rF,c,'Y"x 8iosedtxrt 35tdra wL Gal. k em s a a✓ r - _ y. V�?mss��isedtsyar wor[�r(g;crop Range x MN a � ., trsr g! p to 90 For more information on FiberTite Systems and essories pteaso r-lberl'it-6 SeamanCorporation (BBC)1927.8578 international (330) 262-1111 www.fibedite.com INTELLIGENT ROOnNG SOLUTIONS Rberrde' is a registered trademark of Seaman Corporation. OSubmay cot tom conditions inonsof Approval for d ��� may covering when6mslatledesdescribed cif. Cp °'°'ai°r" cr� �— F1.7?TiiB In the current edition of the Approval Gulde. A850CIAilON. IaC. O+ As to an external two exposure ordy. See UL directory of products certifiedfor Carotid��Onp ntn C 8S and UL roofing materials and systems eospat directory 34KL, 48PO. 97P9. FTR Termination Bar is designed and intended for attaching and sealing FiberTite membrane and flashing terminations. FTR Termination Bar is designed and intended for use with FiberTite Roofing Systems (FTR). FTR Termination Bar is made of corrosion -resistant extruded 6063 T5 aluminum with a mill type finish. Bars are pre -punched with slotted holes measuring 0.28 in x 0.38 in (0.66 cm x 0.97 cm) at 7.8 in (2.0 cm) intervals. Each FTR Termination bar measures 10 ft (3m) in length. There are no minimum quantities required for packaging. Fasteners with metal, neoprene backed sealing washers are to be used when bars are going to be exposed to the weather. Seaman Corporation offers a variety of fasteners for use with FTR Termination Bars as substrates dictate. Seaman Corporation's FTR Termination Bar is designed for mechanical attachment to either provide linear restraint at flashing transitions or compression seals at flashing termination points. Consuitthe mostcurrentversionsofSeaman Corporation's Guide Specifications for the Installation of FiberTite Roofing Systems and Installation Details for installation requirements, cautions and parameters. �,+,T editv7thFu "�?' �• � ,s r�� e - v �, .L° 'C` - .a -a �- .'�. -ry Thickness tas: ai o�2�rntos un} � fi� •. Wirth dR o Se N v! F s,IcO uP Width o 2�in t0�s4 f k� �z��s ? xx 11 „1 �x�y,��++'���-".�Wyv„z c:5 F..3F,.K*'s�,P';F ``k{ :. Y°t_. ��iC.3,. �'a*.`"4 SMr.'W.-X Flat ear width t01n t2i5 me ~r row For more information on FiberTite Systems and accessories pleaso�� Seaman Corporation oral 2628 0) 27-8578 -1111 wwYcliiberthe.com INTELLIGENT ROOFING SOU1nONS FiborTdot is a registered trademark of Soaman Corporation. CR UIPA-ASSOCIA 11-0N. arnnr Seatnan Corporation offers three distinct products to enhance roof traffic safety and optimize n-iembrane protection in roof areas where fiequeiit HV&C maintenance is required. Fbei-Tite Mellow Yellow walkway material is manufactured from a proprietary Seaman Corporation KEE modified vinyl formulation with UV stable yellow pigment and deep herring bone ribbed texture to improve footing on wet surfaces. FiberTite Tuff-Trac protection material features our FiberTite- XTreme membrane's 46 x 44/1,000 x 1,000 denier woven polyester fabric reinforcement, is coated with a proprietary yellow Seaman Corporation KEE formulation and embossed with a low profile diamond plate design. FberTite Grey protection pads are manufactured from high grade vinyl and incorporate a deep herring bone ribbed embossed surface texture. Walkway and protection materials are used to provide defined paths to facilitate common rooftop traffic and traffic involved in regular servicing, maintenance and repairs. FiberTite walkway and protection materials are designed to improve slip resistance, promote positive traction and offer protection from potential damage caused by dropped tools or mishandled equipment. FiberTite walkway and protection materials are to be maintained in specific areas around roof access points (ladders, hatches, doorways, etc.), around mechanical equipment requiring periodic maintenance and as a walkway system on roof areas subject to frequent foot traffic. Mellow Yellow walkway. and Tuff-Trac protection material: Rolls of walkway and/or protection material can easily be cut to various shapes or sizes to facilitate most applications. FiberTite Mellow Yellow walkway and Tuff-Trac protection material is designed to be continuously hot air welded directly to the FiberTite Roof membrane. Grey protection pad: Attach these pads by using hot air to weld 6 in x 6 in (15 cm x 15 cm) strips of FiberTite membrane at the four corners on the back of the pads. Then "tack" weld the strips to the FiberTite Roofing System. Do not weld Grey protection pads directly to the roofing membrane. For additional recommendations and requirements, please consult the most current versions of Seaman Corporation's Guide Specifications for the Installation of FiberTite Roofing Systems. Thickness132in�4rpj)�"�ta g` Breaking Strength (16s) r Elongation 0/6) WC Puncture Resistance t �z3k�1 Thickness icy aorrfrru E 1olSize W zF #rF� 28tnxd3dtf�cmx�' Breaking Strength Obs1 Elongation (%) 7S' '44� i fis.Y INS, ears rehgth Puncture Resistance - , f35p lbs 3 r� Thickness (.��.,,$iZrec"'33viar`#k3,3!,;.,wf`fi`h,...2pftj4ft Breaking Strength C iftyu(%)j Dlmons(�na�ISYabl§ 02 s +S.. z }s Elongation u7lbair�trr��n9tit IIrJA "1 K� xrzr r'-• ��s Puncture Resistance A For more information on FileorTdo Systems n o end acoossodes please call: �b �d International 927-a578 omattonal(330)2G2-t,t imw fibedileeom INTELLIGENT ReOO�FING SOLunONS Fiborndm is a registered trademark of Seaman Corporation. M0 Cr asamxx iION. INC! rasacseaue SP Type S Roof Hatch - Ladder Access - Detail information for Type S Roof Hatch - Ladder ... Page 1 of 2 HOME OUR PRODUCTS COMMERCIAL Login I Register I My Account I Shoppk The Worldwide Source for Specialty Access Products ABOUT BILCO CONTACT US CUSTOMER SERVICE ORDER PARTS TRADE SHOWS Coll Ventilation Products ....................... .—..... _....... Colt Smoke S Fire Curtains Roof Hatches Automatic Smoke Vents r Type S Roof Hatch - Ladder Access Type S roof hatches, 36• x 30• (914mm x 762mm), provide convenient. reliable access to roof areas by means of a fired interior ladder. Product features a counter -balanced cover design for easy one -hand operation and fully gasketed and insulated construction for weather resistance. Available in galvanized steel or aluminum construction. Floor Access Doors bescri ion Pep Finder DowmmL^ ......... ...."""""""""'—'""" p Safety Products ........................................ Roof Hatch Modei : 5-20, 0, 8-60, 8.90 (stainless steel) Intrusion Detection ....................................... Standard Features and Benefits • Miami -Dada County and Florida Buitdino Commission approval for use RESIDENTIAL in high velocity hurricane zones with large and small missile impact' Biko Basement Doors Engineered with compression spring operators to provide smooth, easy, one -hand operation, regardless of size ...... �; .�.................................. "' - Automatic hold -open arm locks the cover in the open Egress Window Wells. position to ensure safe egress ........ . .............................. Overlapping cover design. full welded comers on cover and curb, .. PermEnby Entrance EPDM rubber gasket and fully insulated cover end curb ensure ._...... __......... _................ weather ightness and energy efficiency Contractor Programs Constructed withcorrosion resistant malerials to provide many years of �. ....... __.... ........................ trouble free, dependable service Testimonials Heavy gauge construction and positive latching mechanism maintain , .......... ............................. building security s _•- ems. • Curb features the 80-Cli flashing P® g system, an innovative method to E In Enhanced Now Available n and easily secure single ply rcoficrg material to Bitco roof Performanra Design products products • Available in many sizes and curb configurations to satisfy any Our most Energy Efficient Roof Hater model yet) requirement or installation Click here for more information "Standard Type S-20 and S•50 models are approved Guide Specifications ' • Material (select one): Steel: Cover and frame are 14 gauge (2 mm) G90 paint bond galvanized steel. Aluminum: Cover and frame are 11 gauge (2.3 mm) aluminum. Stainless Steel: Cover and frame are 14 gauge (2 mm) type 304 stainless steel • Cover. Brakefonned, hollow -metal design with 1• (25 mm) concealed fiberglass insulation, 3" (76 mm) beaded, overlapping flange, fully welded at comers, and internally reinforced for 40 psf (195 kglm7) live load. • Curb: 12• (305 rum) in height with integral raptlashing, 1• (25 mm) fiberboard insulation, fully welded at comers, and 3.1/2• (89 mm) mounting flange with 7/16• holes (11 mm) provided for securing frame to the roof deck. • Gasket: Extruded EPDM rubber gasket permanently adhered to cover. Hinges: Heavy-duty pintle hinges with 3W (9 mm) Type 316 stainless steel hinge pins. • Latch: Slam latch with interior and exterior turn handles and padlock hasps. • Lift Assistance: Compression spring operators enclosed in telescopic tubes. Automatic hold -open arts with grip handle release. • Performance Ratings: Complies with UL 790 Class A (burning brand test). • Finish: \ Steel: Alkyd base red oxide primer. Aluminum: Mill Finish. Stainless Steel: Type 3D4 stainless steel with bead blast finish • Hardware: Steel: Engineered composite compression spring tubes with steel compression springs packed in grease. All other hardware is zinc platedlehromate sealed. Aluminum: Engineered composite compression spring tubes with steel compression springs packed in grease. Type 316 Stainless steel hinges. All other hardware is zinc platedictromate sealed. Stainless Steel: Type 316 stainless steel. U.S. Patents 5,660,596 6,347.818 SEARCH 01 keyword(s) c SEAR' SALES CONTA WARRANTY RE( DOWNLOAD Submittal D CAD de' BIM Mop Specifics Installation In: Literati Terms of Usell'&acv Polity. Copyright 2013. Bitco Corporation. All Rights Reserved. LadderUP® Safety Post - Detail information for LadderUP® Safety Post Page 1 of 2 HOME OUR PRODUCTS Login I Register I My Account I Shopph The Worldwide Source for Specialty Access Products ABOUT BILCO CONTACT US CUSTOMER SERVICE ORDER PARTS TRADE SHOWS COMMERCIAL Coll Ventilation Products ........................................ Colt Smoke & Fire Curtains ...................................... Roof Hatches .................................... Automatic Smoke Vents ....................................... Floor Access Doors ...................................... Safety Products ....................................... Intrusion Detection RESIDENTIAL Bilco Basement Doors Egress Window Walls PermEntry Entrance Contractor Programs ........................ Testimonials LadderUP® Safety Post LadderUPO Safety Posts provide easier, safer ladder access through roof hatches; Door, vault and sidewalk doors; and manholes. This telescoping past permanently mounts to the top two rungs of any fixed ladder, providing a positive hand -hold and enabling the user to enter or exit an opening In an upright and balanced position. Description ftep cinder Documents Ladder Safety Post Mode Lll-1 U-2, LU-3, LU-4 Standard Features and Benefits • Adjustable mounting hardware accommodates ,.s. virtually any ladder rung size or spacing. r 4 - • Telescoping design is spring balanced for ease of operation.si • Automatically looks in the fully raised position tom'' - provide the userwith a firm and steady hand -hold for k ph ' ` 1 - saferegress ry n y • Handy release laver allows the post to be easily„ �. lowered to its retracted position. • Available in fourlevels of corrosion resistance to provide marry years of trouble free, dependable service. Specifications` ,fit i Install on fixed ladder(s) below hatch cover(s), LadderUFO safety post Model _ as manufactured by The Bileo Company. Device shag be (refer to chart for materfallfiniste of model specified). It shag be designed with a telescoping, tubular section that locks aulomaficaly when fully r dended. Upward and downward movement shall be controlled by a stainless steel spring balancing mechanism. Unit shall be - completely assembled with fasteners for searing to the ladder rungs in accordance with the manufacturers instructions. If installation is to be in corrosive atmosphere, specify Model LU-2, LU-3 or LU-4 as conditions warrant Also used on fixed ladders under floor access doors and manhole covers Standard Sizes and Weights Model MatertaUFinish Weight lbs. kg. LU-1 Steel, yellow' powder coat 24 11 LU-2 Sleet, hot dip galvanized 24 11 LU-3 Type 3D4 stainless steel 24 11 LU-4 Aluminum, mill finish 14 7 U.S. Patera 4.546,055 Temps of Use/Privacy Policy. Copyright 2013. Bilco Corporation. All Rights Reserved. PRE' - El SEARCH OI keyword(s) c CgEAR' SALES CONTA WARRANTY RE( DOWNLOAD Submittal D CAD de, BIM Mo. Specifrco Installation In+ Lherah Yob Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Bast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Material Safety Data Sheets Main Office: 804 Old Dixie Highway " Lake Park, FL 33403 ■ Tel: 561.223.2096 Fax: 561.444.2272 License # CCC1328620 Solutions Driven and Customer Focused ,fff Seaman corporation MATERIAL SAFETY DATA SHEET For Coatings Resins and Related Materials M *4� �1 d INTELLIGENT ROOFING SOLUTIONS MSDS NUMBER ISSUE'DATE SUPERCEDES: PREPARED BY: MSDS FTR-KEE 10/30/09 All Previous N/A PRODUCT IDENTITY (as used on label and list): FiberTite Single Ply Membrane Manufacturer / Distributor EMERGENCY PHONE NUMBER(s) NAME: Seaman Corporation ADDRESS: 1000 Venture Blvd. ADDRESS: Wooster, OH '44691 Trade Names or Synonyms: KEE / PVC / Polyester Fabric CAS Number: None D.O.T. Hazard Class: N/A Proper Shipping Name: Roofing Membrane DAY. 330-262-1111 NIGHT (CHEMTREC): 800-424-9300 INFORMATION: 330-262-1111 HMIS Hazard Codes: none: extreme 0 -► 4 Health: 0 Fire: 0 Reactivity: 0 Personal Protection: 0 Ingredients Percent C.A.S. Exposure Limits VP Material Description by Weight Registry Number ACGIH/TLV OSHA/PEL mm HG Proprietary KEE/PVC Compound N/A N/A N/A N/A N/A (Trade Secret Per CFR 1910.1200(i)) Boiling Range: > 350 deg. F Physical State: Solid sheet Volatiles: < 0.2 Appearance: Various colors; slight vinegar odor Vapor Density: Heavier than air Liquid Density: Lighter than water Solubility in Water. Insoluble Spec. Gravity: 1.2 - 1.3 Flammability Class: N/A Flash Point: > 250 TOC LEL: N/A UEL: N/A EXTINGUISHING MEDIA Water fog, foam or dry chemical; CO2 may not have enough cooling capacity to prevent re -ignition. SPECIAL FIREFIGHTING PROCEDURES Avoid breathing smoke. Use Pressure Self -Contained Breathing Apparatus. UNUSUAL FIRE AND EXPLOSION HAZARDS None known 2 FiberTite® MSDS Booklet FTR-KEE Page 1 of 3 10-30-2009 Permissible Exposure Level: N/A Effects of Overexposure Inhalation: Respiratory irritation is possible due to processing vapors when heated sufficiently to cause mass melting of the polymer, such as during heat welding. Eyes: Eye irritation is possible due to processing vapors when film is heated sufficiently to cause mass melting of the polymer, such as during heat welding. Skin: Skin irritation is possible due to processing vapors when film is heated sufficiently to cause mass melting of the polymer, such as during heat welding. Ingestion: Not normally a route of exposure. First Aid Inhalation: Remove to fresh air. If respiratory irritation occurs, call physician. Skin: Wash with -mild soap and water. Eyes: Remove to fresh air. If irritation occurs, call physician. Ingestion: N/A Stability: ❑ Unstable 0 Stable Hazardous Polymerization: ❑ May occur ® Will not occur Incompatibility: N/A Conditions to Avoid: ombustible if exposed to flame Hazardous Decomposition Products: CO, CO2, Acetic Acid, Trace Aromatics. Steps to Be Taken in Case Material is Released or Spilled: Dispose in Approved Landfill Waste Disposal Method: Bury or incinerate in accordance with local, state, and federal regulation. Not defined as Hazardous by current provisions of RCRA. Respiratory Protection: Not normally necessary. Ventilation: Local exhaust, especially if irritation occurs. Protective Gloves: Wear gloves when handling hot material. Eye Protection: Not normally necessary. Other Protective Equipment: Not normally necessary. Precautions to be Taken in Handling and Storage: In operations such as heat welding or thermoforming involving heat sufficient to cause melting of the polymer, irritating fumes may be evolved. Adequate ventilation should be provided. Other Precautions: Avoid inhalation of processing fumes. FTR-KEE FiberTitea MSDS Booklet 3 Page 2 of 3 10-30-2009 SARA Title III Section 313 This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and. Community Right to Know Act of 1986 and of 40 CFR 372: CAS# Chemical Name Percent by Weight None PROP 65 (Carcinogen) Warning:This product contains a chemical known to the state of California to cause cancer. CAS# Chemical Name Percent by Weight None PROP 65 (Teratogen) Warning:This product contains a chemical known to the state of California to cause birth defects or other reproductive harm. CAS# Chemical Name Percent by Weight None - PROP 65 (Both Carcinogen and Teratogen) Warning:This product contains a chemical known to the state of California to cause cancer or birth defects or other reproductive harm. CAS# Chemical Name Percent by Weight None N/A= Information or Data Not Available. OSHA= Occupational Safety and Health Administration NTP= National Toxicology Program PEL= Permissible Exposure Limit (8-hr. TWA) (OSHA) IARC= International Agency for Research on Cancer TLV= Threshold Limit Value (8-hr. TWA) (ACGIH) NIOSH= National Institute of Occupational Safety and- Health STEL= Short Term Exposure Limit (15-min TWA) (OSHA) ACGIH= American Conference of Governmental Industrial Hygienists C= Ceiling Value This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best of Seaman Corporation's knowledge, or is obtained from sources believed by Seaman Corporation to be accurate. No warranty is expressed or implied regarding the accuracy of this information or the results to be obtained from its use thereof. Seaman Corporation assumes no responsibility for injuries proximately caused by use of the material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally, Seaman Corporation assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety procedures are followed. Buyer assumes the risk in its use of the material. 4 FiberTite° MSDS Booklet FTR-KEE Page 3 of 3 10-30-2009 ,f,ff Seaman Corporation MATERIAL SAFETY DATA SHEET For Coatings Resins and Related Materials �be'etE INTELLIGENT ROOFING SOLUTIONS MSDS NUMBER ISSUE DATE SUPERCEDES: PREPARED BY MSDS FTR-KEE2 10/30/09 All Previous N/A PRODUCT IDENTITY (as used on label and list): FiberTite Single Ply Membrane Manufacturer / Distributor EMERGENCY PHONE NUMBER(s) NAME: Seaman Corporation ADDRESS: 1000 Venture Blvd. ADDRESS: Wooster, OH 44691 Trade Names or Synonyms: KEE / PVC Membrane CAS Number: None D.O.T. Hazard Class: N/A Proper Shipping Name: Roofing Membrane DAY: 330-262-1111 NIGHT (CHEMTREC): 800-424-9300 INFORMATION: 330-262-1111 HMIS Hazard Codes: none: extreme 0 ---► 4 Health: 0 Fire: 0 Reactivity: 0 Personal Protection: 0 Ingredients Percent C.A.S. Exposure Limits VP Material Description by Weight Registry Number ACGIH/TLV OSHA/PEL mm HG Proprietary KEE/PVC Compound N/A N/A N/A N/A N/A (Trade Secret Per CFR 1910.1200(i)) Boiling Range: > 350 deg. F Physical State: Solid sheet Volatiles: < 0.2 Appearance: Various colors; slight vinegar odor Vapor Density: Heavier than air Liquid Density: Lighter than water Solubility in Water: Insoluble Spec. Gravity: 1.2 - 1.3 Flammability Class: N/A Flash Point: > 250 TOC LEL: N/A UEL: N/A EXTINGUISHING MEDIA Water fog, foam or dry chemical; CO2 may not have enough cooling capacity to prevent re -ignition. SPECIAL FIREFIGHTING PROCEDURES Avoid breathing smoke. Use Pressure Self -Contained Breathing Apparatus. UNUSUAL FIRE AND EXPLOSION HAZARDS None known FTR-KEE2 Page 1 of 3 10-30-2009 FiberTiteo MSDS Booklet 5 Permissible Exposure Level: N/A Effects of Overexposure Inhalation: Respiratory irritation is possible due to processing vapors when heated sufficiently to cause mass melting of the polymer, such as during heat welding. Eyes: Eye irritation is possible due to processing vapors when film is heated sufficiently to cause mass melting of the polymer, such as during heat welding. Skin: Skin irritation is possible due to processing vapors when film is heated sufficiently to cause mass melting of the polymer, such as during heat welding. Ingestion: Not normally a route of exposure. First Aid Inhalation: Remove to fresh air. If respiratory irritation occurs, call physician. Skin: Wash with mild soap and water. ' Eyes: Remove to fresh air. If irritation occurs, call physician. Ingestion: N/A Stability: ❑ Unstable ® Stable Hazardous Polymerization: I] May occur 0 Will not occur Incompatibility: N/A Conditions to Avoid: Combustible if exposed to flame. Hazardous Decomposition Products: CO, CO2, Acetic Acid, Trace Aromatics Steps to Be. Taken, in Case Material is Released or Spilled: Dispose in Approved Landfill Waste Disposal Method: Bury or incinerate in accordance with local, state, and federal regulation. Not defined as Hazardous by current provisions of RCRA. Respiratory Protection: Not normally necessary. Ventilation: Local exhaust, especially if irritation occurs. Protective Gloves: Wear gloves when handling hot material. Eye Protection: Not normally necessary. Other Protective Equipment: Not normally necessary. Precautions to be Taken in Handling and Storage: In operations such as heat welding or thermoforming involving heat sufficient to cause melting of the polymer, irritating fumes may be evolved. Adequate ventilation should be provided. Other Precautions: Avoid inhalation of processing fumes. 6 FiberTite° MSDS Booklet FTR-KEE2 Page 2 of 3 10-30-2009 SARA Title III Section 313 This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and Community Right to Know Act of 1986 and of 40 CFR 372: CAS# Chemical Name Percent by Weight None PROP 65 (Carcinogen) Warning:This product contains a chemical known to the state of California to cause cancer. CAS# Chemical Name Percent, by Weight None PROP 65 (Teratogen) Warning:This product contains a chemical known to the state of California to cause birth defects or other repro- ductive harm. CAS# Chemical Name Percent by Weight None PROP 65 (Both Carcinogen and Teratogen) Warning:This product contains a chemical known to the state of California to cause cancer or birth defects or other reproductive harm. CAS# Chemical Name Percent by Weight None N/A= Information or Data Not Available. OSHA= Occupational Safety and Health Administration NTP= National Toxicology Program PEL= Permissible Exposure Limit (8-hr. TWA) (OSHA) IARC= International Agency for Research on Cancer TLV=Threshold. Limit Value (8-hr. TWA) (ACGIH) NIOSH= National Institute of Occupational Safety and Health STEL= Short Term Exposure Limit (15-min TWA) (OSHA) ACGIH= American Conference of Governmental Industrial Hygienists C= Ceiling Value This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best of Seaman Corporation's knowledge, or is obtained from sources believed by Seaman Corporation to be accurate. No warranty is expressed or implied regarding the accuracy of this information or the results to be obtained from its use thereof. Seaman Corporation assumes no responsibility for injuries proximately caused by use of the material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally, Seaman Corporation assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety procedures are followed. Buyer assumes the risk in its use of the material. FTR-KEE2 FiberTite° MSDS Booklet Page 3 of 3 10-30-2009 Seaman corporation MATERIAL SAFETY DATA SHEET For Coatings Resins and Related Materials INTELLIGENT ROOFING SOLUTIONS MSDS NUMBER ISSUE DATE SUPERCEDES: PREPARED BY: MSDS FTR-190e 10/30/09 All Previous N/A PRODUCT IDENTITY (as used on label and list): FTR-1906 Bonding Adhesive Manufacturer / Distributor EMERGENCY PHONE NUMBER(s) NAME: Seaman Corporation ADDRESS: 1000 Venture Blvd. ADDRESS: Wooster, OH 44691 Trade Names or Synonyms: Low VOC Bonding Adhesive CAS Number: Mixture D.O.T. Hazard Class: Hazard Class 3 Proper Shipping Name: Adhesives Packing Group II DAY 330-262-1111 NIGHT (CHEMTREC): 800-424-9300 INFORMATION: 330-262-1111 HMIS Hazard Codes: none: Health: Fire: Reactivity: Personal Protection: UN #: -;' extreme 0 -► 4 2 3 1 B UN1133 Ingredients Percent C.A.S. Exposure Limits Material Description by Weight Registry Number TSCA ACGIH/TLV OSHA/PEL ACGIH METHYL ETHYL KETONE 1-5 78-93-3 Y 200.00 PPM 200.00 PPM 300.00 PPM ACETONE 55-75 67-64-1 Y 500.00 PPM 1000.00 PPM 750.00 PPM TOLUENE 1-5 108-88-3 ' Y 50.00 PPM 200.00 PPM N/est Boiling Range: 133° F Vapor Density: Heavier than air Evap. Rate: Faster than n-Butyl Acetate Liquid Density: Lighter than water % Volatile Weight: 74.8 Wgt. per gallon: 7.08 pounds % Volatile Volume: N/A' Spec. Gravity: 0.85031 Appearance: Amber; typical odor Photo Chem Reactive Only VOC: 53 EPA Method 24 VOC: 199.4 g/L Flammability Class: IB Flash Point: 23' F TOC LEL %: 1.2 UEL %:-10.0 EXTINGUISHING MEDIA Foam, dry chemical, carbon dioxide, water spray or fog. SPECIAL FIREFIGHTING PROCEDURES Avoid breathing smoke. Use air supplied rescue equipment for enclosed area. Water tends to spread burning liquid if large amounts are used. UNUSUAL FIRE AND EXPLOSION HAZARDS Extremely flammable. Vapors may ignite and/or cause flash fires. Eliminate sources of ignition. No smoking. Use adequate cross ventilation sufficient to remove odor of solvent or vapors. Electrically ground all containers during transfer. FiberTite MSDS Booklet FTR-190e Page 1 of 3 10-30-2009 Permissible Exposure Level: See Section II Effects of Overexposure Inhalation: May cause nose or throat irritation. High concentrations may cause acute central nervous system depression characterized by headache, dizziness, nausea, and confusion. Eyes: May cause severe eye irritation and corneal damage. Skin: May cause dermatitis. May cause defatting and irritation of the skin. Ingestion: Can cause gastrointestinal irritation, nausea and vomiting. Aspiration of material into lungs may cause chemical pneumonitis which can be fatal. First Aid Inhalation: Move victim to fresh air. If breathing has stopped, give artificial respiration. Seek immediate medical attention. Skin: Wash with mild soap and water for 15 minutes. If irritation persists consult a physician. Eyes: Flush with water for at least 15 minutes and seek immediate medical attention. Ingestion: Do not induce vomiting. Seek immediate medical attention. Stability: O Unstable ® Stable Hazardous Polymerization: ❑ May occur RI Will not occur Incompatibility: Strong oxidizing agents, strong acids and bases. Conditions to Avoid: Fire, sparks, static electricity. Hazardous Decomposition Products: Carbon monoxide, carbon dioxide. Steps to Be Taken in Case Material is Released or Spilled: Keep spectators away. Eliminate all ignition sources (flames, hot surfaces and sources of electrical, static or frictional sparks). Dike and contain spill with inert material (e.g. sand, earth). Transfer liquids to covered metal containers for recovery or disposal, or remove with inert absorbent. Use only non -sparking tools. Place absorbent diking materials in covered metal containers for disposal. Prevent contamination of sewers, streams and groundwater with spilled material or used absorbent. Waste Disposal Method: Dispose of in accordance with federal, state and local regulations. Respiratory Protection: If workplace exposure limit of product is exceeded, a NIOSH/MSHA approved air supplied respirator must be used in absence of proper environmental control. Engineering or administrative controls should be implemented to reduce exposure. Ventilation: Provide sufficient mechanical (general and/or local exhaust) ventilation to maintain`exposure below PEL Protective Gloves: .Chemical resistant gloves. Eye Protection: Safety glasses. Face shield as necessary if spraying. Other Protective Equipment: Barrier cream for sensitive skin. FTR-190e FiberTite9 MSDS Booklet 9 Page 2of3 10-30-2009 Precautions to be Taken in Handling and Storage: Keep container closed when not in use. Store at 60 - 95 degrees F and out of sun. Use adequate ventilation to avoid breathing vapor when cover is removed. Ground all equipment when handling flammable solvent borne materials. Other Precautions: For professional or industrial use only. Follow label instructions. Keep out of the reach of children. Not for consumption. No smoking. Do not breathe fumes. Avoid contact with body. Turn off all pilot lights, flames, stoves, heaters, electric motors, welding equipment and other sources of ignition. Close all containers when not in use. Empty containers must not be washed and re -used for any purpose. Contact lens wearers take appropriate precaution. Wash hands thoroughly after handling. For spray applications, use only with approved spray equipment. For flammable products, vapors may cause flash fire or ignite explosively. To prevent buildup of vapors, use adequate ventilation (e.g. open all windows and doors to achieve cross -ventilation). Containers may be hazardous when empty. Never use welding or cutting torch on or near container. SARA Title III Section 313 This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and Community Right to Know Act of 1986 and of 40 CFR 372: CAS# Chemical Name Percent by Weight 78-93-3 Methyl Ethyl Ketone 1-5 108-88-3 Toluene 1-5 PROP 65 (Teratogen) Warning -This product contains a chemical known to the state of California to cause birth defects or other reproductive harm. CAS# Chemical Name Percent by Weight 108-88-3 Toluene 1-5 The following ingredients are registered for TSCA 12B CAS# Chemical Name Percent by Weight 67-64-1 ACETONE 55 - 75 N/A= Information or Data Not Available. OSHA= Occupational Safety and Health Administration NTP= National Toxicology Program PEL= Permissible Exposure Limit (8-hr. TWA) (OSHA) IARC= International Agency for Research on Cancer TLV= Threshold Limit Value (8-hr. TWA) (ACGIH) NIOSH= National Institute of Occupational Safety and Health STEL= Short Term Exposure Limit (15-min TWA) (OSHA) ACGIH= American Conference of Governmental Industrial Hygienists C= Ceiling Value This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best of Seaman Corporation's knowledge, or is obtained from sources believed by Seaman Corporation to be accurate. No warranty is expressed or implied regarding the accuracy of this information or the results to be obtained from it's use thereof. Seaman Corporation assumes no responsibility for injuries proximately caused by use of the material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally, Seaman Corporation assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety procedures are followed. Buyer assumes the risk in its use of the material. 10 FiberTite® MSDS Booklet FTR-190e Page 3 of 3 10-30-2009 "Seaman Corporation MATERIAL SAFETY DATA SHEET For Coatings Resins and Related Materials MSDS NUMBER ISSUE DATE SUPERCEDES: MSDS FTR-VALUE 10/30/09 All Previous PRODUCT IDENTITY (as used on label and list): FTR-VALUE. Insulation Manufacturer / Distributor NAME: Seaman Corporation ADDRESS: 1000 Venture Blvd. ADDRESS: Wooster, OH 44691 Trade Names or Synonyms: Polyisocyanurate foam insulation CAS Number. Mixture D.O.T. Hazard Class: N/A Proper Shipping Name: Insulation Ingredients Material Description Polyisocyanurate Foam Proprietary Hydrocarbons Fibrous Glass Cellulose riberllrii INTELLIGENT ROOFING SOLUTIONS PREPARED BY - N/A EMERGENCY PHONE NUMBER(s) DAY. 330-262-1111 NIGHT (CHEMTREQ 800-424-9300 INFORMATION: 330-262-1111 HMIS Hazard Codes: none: Percent C.A.S. by Weight Registry Number N/A NONE N/A 1717-00-6 N/A 65997-1773 N/A NONE Health: Fire: Reactivity: Personal Protection: UN #: --► extreme 1 1 D 1 NIA Exposure Limits ACGIH/TLV OSHA/PEL NONE < 60 500 <10 10 <4 10 <26 Boiling Range: N/A Vapor Density: N/A Specific Gravity: 2.0 Ibs/cu. ft. Solubility in Water: N/A Volatiles: N/A Appearance and Odor: Tan core foam with cellulose glass fiber facings; odorless Flash Point: N/A EXTINGUISHING MEDIA Foam, dry chemical, carbon dioxide, water fog. SPECIAL FIREFIGHTING PROCEDURES Full face self-contained breathing apparatus in conjunction with impervious protective clothing. UNUSUAL FIRE AND EXPLOSION HAZARDS None known. Avoid direct contact with flame. Burning foam my emit thick, black toxic smoke. STORAGE OF MATERIAL: Class 2 Commodity (UFC) FTR-VALUE FiberTitea MSDS Booklet 27 Page 1 of 3 10-30-2009 Signs of Overexposure: Acute temporary mechanical irritation of eyes, nose, throat, lungs and possibly skin. Primary routes of Exposure: Irritation and skin contact Eyes: Irritation Skin: Can cause irritation, dermatitis. First Aid Inhalation: Leave area to breathe fresh air. Drink water to clear throat and blow nose to remove dust. Skin: Wash with soap and water. Eyes: Flush with water for at least 15 minutes or until irritation ceases. If irritation persists, contact a physician. Stability: ❑ Unstable 0 Stable Hazardous Polymerization: C3 May occur ® Will not occur Incompatibility: Acetone, ketone, methyl, ethyl chemical families. Conditions to Avoid: Will burn if exposed to fire or sufficient heat intensity. Can release black toxic smoke if ignited. Hazardous Decomposition Products: Like wood and other organic materials. Steps to Be Taken in Case Material is Released or Spilled: Vacuum dust. If sweeping is necessary use a dust suppressant such as water. Waste Disposal Method: Dispose of in accordancewith federal, state and local regulations. Respiratory Protection: A respirator may be used. Breathing dust from this product may cause irritation to the upper respiratory tract. Ventilation: Sufficient to keep workroom concentration below TLV. Ingestion: This product is not intended to be ingested. It may cause irritation to the gastrointestinal tract. Eye Protection: Safety glasses with eye shields are recommended. Other Protective Equipment: Loose -fitting long-sleeved clothing and leather gloves may help prevent skin irritation. Precautions to be Taken in Handling and Storage: Persons who develop irritation, respiratory problems, or puffiness around the eyes should be examined by a physician as soon as possible. Other Precautions: None 28 FiberTiteb MSDS Booklet FTR-VALUE Page 2of3 10-30-2009 Not completely classified or classifiable. l N/A= Information or Data Not Available. OSHA= Occupational Safety and Health Administration NTP= National Toxicology Program PEL= Permissible Exposure Limit (8-hr. TWA) (OSHA) IARC= International Agency for Research on Cancer TLV= Threshold Limit Value (8-hr. TWA) (ACGIH) NIOSH= National Institute of Occupational Safety and Health STEL= Short Term Exposure Limit (15-min TWA) (OSHA) ACGIH= American Conference of Governmental Industrial Hygienist's C= Ceiling Value This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best'of Seaman Corporation's knowledge, or is obtained from sources believed by Seaman Corporation to be accurate. No warranty is expressed or implied regarding the accuracy of this information or the results to be obtained from its use thereof. Seaman Corporation assumes no responsibility for injuries proximately caused by use of the material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally, Seaman Corporation assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety procedures are followed. Buyer assumes the risk in its use of the material. FTR-VALUE FiberTite° MSDS Booklet 29 Page 3 of 3 10-30-2009 AF seaman Corporation MATERIAL SAFETY DATA SHEET For Coatings Resins and Related Materials i'1l�EP� INTELLIGENT ROOFING SOLUTIONS MSDS NUMBER ISSUE DATE SUPERCEDES: PREPARED BY: MSDS FTR-101 10/30/09 All Previous N/A PRODUCT IDENTITY (as used on label and list): FTR-101 Sealant Manufacturer / Distributor NAME: Seaman Corporation ADDRESS: 1000 Venture Blvd. - ADDRESS: Wooster, OH 44691 Trade Names or Synonyms: Sealaht/Caulking CAS Number: None/Mixture D.O.T. Hazard Class: N/A Proper Shipping Name: Sealant/Adhesive EMERGENCY PHONE NUMBER(S) DAY. 330-262-1111 NIGHT (CHEMTREC): 800-424-9300 INFORMATION: 330-262-1111 HMIS Hazard Codes: none: -----*--extreme 0-'4 Health: 2 Fire: 2 Reactivity: 0 Personal Protection: G Ingredients Percent C.A.S. Material Description by Weight Registry Number LEL VP Titanium Dioxide < 5 13463-67-7 N/A N/A Calcium oxide (lime) 1 to 5 1305-78-8 None None Talc (hydrous magnesium silicate) 1 to 5 14807-96-6 None None Aluminum sulfate (alum) 1 to 5 10043-01-3 None None Calcium carbonate (limestone) 10 to 30 1317-65-3 None None 2, 4-Toluene diisocyanate* < 0.1 584-84-9 1 < 1 Mineral spirits (Stoddard type) 5 to 10 8052-41-3 1 2 * Reportable under SARA Title III, Section 313 Boiling Range: 240-450° F Freezing Point: No Data Vapor Pressure: < 2mm Hg at 77° F Vapor Density: Heavier than air Evap. Rate Relative to n-butyl acetate: Slower Water Soluble: Slight (<0.1%) % Volatile by Volume: 6 to 8 Spec. Gravity: 1.1 Odor Threshold: No Data Appearance: Smooth pigmented viscous liquid. Typical paint thinner odor FTR-101 FiberTite MSDS Booklet 35 Page 1 of 5 10-30-2009 Flash Point: >2000 F OSHA Flammability Classification: Combustible Class III B Autoignition Temp: No Data LEL: 0.9 Explosive Limits: (%V in air) UEL: 7.0 EXTINGUISHING MEDIA . Water Spray (Fog), Foam, Dry Chemical or Carbon Dioxide. SPECIAL FIREFIGHTING PROCEDURES Firefighters must wear self contained breathing apparatus or air masks. Containers exposed to fire should be kept cool with water spray. A water stream directed into the fire may cause frothing with subsequent spread of fire. UNUSUAL FIRE AND EXPLOSION HAZARDS Closed containers may explode due to build up of pressure when exposed to heat. Thermal decomposition or combustion of product may generate irritating and/or toxic gases. Vapor is heavier than air and may travel along °the ground or floor and be ignited at locations distant from the source. Ingredient PEL TLV STEL TLV (twa) LD50 (mg/kg) LC50 (ppm) Material Description (mg/m3) (mg/m3) (mg/m3) ppm Rat Rabbit Rat (oral) (dermal) inhal Titanium dioxide 10* N/A 10* N/A N/A N/A N/A Calcium oxide (lime) 5* Not Given 2* N/A N/A N/A N/A Talc (hydrous magnesium silicate) 2* Not Given 2* N/A N/A N/A N/A Aluminum sulfate (alum) 15*, 5** Not Listed 10* N/L N/L N/L No Data Calcium carbonate (limestone) 15*, 5** Not Listed 10* N/L N/L N/L No Data 2,4-toluene diiscocyanate* 0.005 ppm 0.02 ppm N/L 0.005 >5800 >1600 . No Data Mineral spirits (Stoddard type) 100 ppm Not Listed N/L 100 >5000 N/L No Data *Total Dust **Respirable Dust Threshold Limit Values: See Section V Acute Overexposure Information Inhalation: Regard this product as a severe irritant. The product may contain trace amounts of an isocyanate. Exposure to a concentration of airborne isocyanates above TLV may produce irritation of the respiratory tract, coughing, chest discomfort, and shortness of breath. Individuals with a history of exposure to isocyanates can develop more severe symptoms, such as bronchitis, bronchial spasms, and pulmonary edema (fluid in the lungs). For most individuals these effects are reversible. Eyes: Moderate irritant. May cause tearing, reddening of the eyes and reversible corneal injury. Skin: Regard this product as a severe irritant. The product may contain trace amounts of an isocyanate, a class of compounds generally regarded as primary skin irritants. Contact with the product may cause dermatitis, allergic responses, and in sensitive individuals, redness, swelling, and, blisters. Ingestion: May cause irritation if swallowed. Note: Pre-existing respiratory or skin condition(s) may be aggravated by exposure. 36 FiberTite® MSDS Booklet FTR-101 Page 2 of 5 10-30-2009 Chronic Overexposure information: 1.This product does not contain dust as produced and does not generate dust in normal use. Dust generated by abnormal activities, such as sanding or grinding, could contain a small amount (<O.1%) of respirable silicone dioxide (quartz) dust. NTP and IARC have listed free respirable silica as a suspect human carcinogen. Prolonged and/or repeated overexposure to free respirable silica may cause silicosis or other delayed and serious lung injury. The dust could also contain particles of titanium dioxide, calcium oxide, talc, aluminum sulfate, and/or calcium carbonate. Chronic overexposure to dusts of these substances may cause delayed and serious lung injury. 2. This product may contain a small amount (< 0.1%) of toluene diisocyanate. NIOSH, NTP and IARC list toluene diisocyanate as a suspected carcinogen. Note also that prolonged or repeated exposure to isocyanates can lead to skin sensitization. For persons so sensitized, even brief exposures to the isocyanates can produce reddening, swelling, rash, or blisters. Similarly, prolonged and repeated exposures to isocyanates at levels well below the TLV can produce chemical asthma, and nonspecific asthmatic conditions. 3. No other known components of this product are listed as known or suspected carcinogens per NTP, IARC, or OSHA. 4. This product contains solvents. Reports have associated repeated and prolonged occupational over -exposure to solvents with permanent brain and nervous system damage. Solvents are also reported to cause liver damage, kidney damage, mucous membrane irritation. Be warned that intentional misuse by deliberately inhaling the contents ( a process often called "sniffing" ) may be harmful or fatal. Medical Conditions Generally Aggravated by Exposure: Any pre-existing respiratory or skin condition. Emergency and First Aid Procedures: Inhalation: Move the victim into fresh air. If the victim has difficulty breathing, administer oxygen. Administer artificial respiration if the victim is not breathing. Obtain immediate medical attention. Skin: Remove contaminated clothing and shoes. Wash affected area(s) thoroughly with soap and water. Wipe or flush affected skin with isopropyl alcohol (rubbing alcohol). Wash again thoroughly with soap and water. If irritation persists, seek medical attention. Eyes: Flush the eyes with plenty of water for at least 15 minutes. If necessary, gently hold the eyelids open during the flush. Obtain immediate medical attention. Ingestion: Obtain immediate medical medical attention. Do not induce vomiting. Should vomiting occur, be sure to keep victim's head below hips to avoid aspiration of vomitus into the lungs. Stability: ❑ Unstable ® Stable Hazardous Polymerization: ® May occur ❑ Will not occur This product contains an isocyanate. Contact with moisture or other materials that react with isocyanates may cause polymerization. Incompatibility: Water, alcohols, amines, strong oxidants, strong bases and acids. Conditions to Avoid: Contact with water vapor. Sources of ignition. Long term exposure to elevated temperatures. Hazardous Decomposition Products: Oxides of carbon and nitrogen, hydrogen cyanide gas, other acids and toxic fumes FTR-101 FiberTite MSDS Booklet 37 Page 3 of 5 10-30-2009 Steps to Be Taken in Case Material is Released or Spilled: Ventilate the area and remove all sources of ignition. Evacuate unnecessary personnel. Wipe up small spills with rags or towels. Put spent rags in loosely covered containers in a well ventilated area. Large spills should be handled carefully. Put on respiratory protection. Dike or impound spilled liquid. Cover the spill with absorbent compound (eg., vermiculite, clay, or sand). Use non -sparking tools to sweep or shovel into containers. Cover loosely and remove to a well -ventilated waste area. Repeat sorbent/sweep cycle until the.spill has dried up. Rinse the spill area thoroughly with water. Flush the rinsings to the sanitary sewer or soak them up with absorbent material. Do not discharge undiluted product to the sanitary sewer or discharge the product or cleanup wastes to lakes, streams, ponds, or sewer. Avoid contact with eyes and skin. Waste Disposal Method: Review all local, state, and federal regulations concerning health and pollution for appropriate disposal procedures. Do not incinerate closed containers. Respiratory Protection: Wear NIOSH/MSHA approved respiratory protection when the product is mixed'or applied in a poorly ventilated area or if workplace levels of ingredients exceed the TW Follow applicable federal, state, and local regulations. Ventilation: Use local exhaust (e.g., open windows, fans) as needed to keep vapor/dust levels below recommended limits. Protective Equipment: Wear gloves (Natural or butyl rubber, supported PVA, or nitrite. Avoid neoprene.), eye goggles, and clean protective clothing to cover arms and legs and keep exposure to a minimum. Precautions to be Taken in Handling and Storage: DO NOT BREATHE VAPORS DO NOT TAKE INTERNALLY AVOID CONTACT WITH EYES, CLOTHING, AND SKIN WEAR PROTECTIVE CLOTHING AT ALL TIMES KEEP CONTAINER CLOSED WHEN NOT IN USE WASH THOROUGHLY AFTER USING KEEP OUT OF REACH OF CHILDREN USE ONLY WITH ADEQUATE VENTILATION 38 FiberTite° MSDS Booklet FfR-101 Page 4 of 5 10-30-2009 VOC CONTENT. 81.6 g/1 excluding water and exempt compounds. CALIFORNIA PROPOSITION 65: The dust from this product may contain trace amounts of free respirable crystalline silicone dioxide, a substance listed by the state of California as known to cause cancer. This product may contain trace quantities (<0.1 %) toluene diisocyanate which is listedby the state of California as known to cause cancer. Medium bronze (32-968) and and Redwood (32-969) colors may contain trace quantities (<O.1%) of lead which is listed by the state of California as known to cause reproductive toxicity. TRANSPORTATION: DOT UN HAZARD CLASS: Not Regulated Not Regulated UN/NA NUMBER: Not Regulated Not Regulated SHIPPING NAME: Not Regulated Not Regulated PLACARD AT: N/A N/A CLASS NUMBER: N/A Air: N/A Marine: N/A SUBSID RISK: N/A Air: N/A Marine: N/A PACKING GROUP: N/A Air: N/A Marine: N/A REPORTING CERCLAA-REPORTABLE QUANTITY: None_ WASTE: None SARA SECTION 304 EMERGENCY RESPONSE REPORTABLE QUANTITY: None SARA SECTION 311/312 INVENTORY REPORTING (Y/N): Y SARA SECTION 311/312 HAZARD CLASS (ES): Acute and chronic health hazard SARA SECTION 313 ROUTINE RELEASE REPORTING CHEMICALS: None COMPONENTS ON TSCA INVENTORY (Y/N): Y DISPOSAL EPA RCRA WASTE CLASS: Not Regulated EPA RCRA WASTE NUMBER: Not Regulated CALIFORNIA LIST LAND BAN (Y/N): Not Regulated N/A= Information or Data Not Available. OSHA= Occupational Safety and Health Administration NTP= National Toxicology Program PEL= Permissible Exposure Limit (8-hr. TWA) (OSHA) IARC= International Agency for Research on Cancer TLV= Threshold Limit Value (8-hr. TWA) (ACGIH) NIOSH= National Institute of Occupational Safety and Health STEL= Short Term Exposure Limit (15-min TWA) (OSHA) ACGIH= American Conference of Governmental Industrial Hygienists C= Ceiling Value This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best of Seaman Corporation's knowledge, or is obtained from sources believed by Seaman Corporation to be accurate. No warranty is expressed or implied regarding the accuracy of this information or the results to be obtained from its use thereof. Seaman Corporation assumes no responsibility for injuries proximately caused by use of the material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally; Seaman Corporation assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety, procedures are followed. Buyer assumes the risk in its use of the material. FTR-101 FiberThea MSDS Booklet 39 Page 5 of 5 10-30-2009 Date: October 24, 2014 Roofing Submittal Project Name: PGA Clubhouse at the Reserve 1916 Perfect Dr. Port St.Lucie, FL 34986 Contractor: Kast Construction 701 Northpoint Parkway, Suite 400 West Palm Beach, FL 33407 Submittal: Shop Drawings Main Office: 804 Old Dixie Highway Lake Park, FL 33403 • Tel: 561.223.2096 ■ Fax: 561.444.2272 License•# CCC1328620 Solutions Driven and Customer Focused r ;rfe I: Vsl t� N...rWl..rl. rW..I,• �.n. a.Veni .•-1.19 Iba m�+na a ui Yn u . 4: .e• avol `/s a..H ••vu. CafTly . qlb :nlM.p� 1.1• ,nN.t• V. nY MWIM ..- -1-1-Y .u�iwl •[' [.W 1114r11r !t•/•f. vors l�Va•1. �f, +rt.uf tv.V a e7 e...m c.t�.nu.a crcu.a s:a.m.. 9 INSOLAi1ON PROFILES NOI 70 SME PGA CLUBHOUSE AT THE RESERVE PORT ST LUCIE . FL. �wp.� •� .fah 1,h11 v.lr� O[V_C' la cAT= (46056 10/77/74 S�fhLF._ 11-1/2" — (4 cm) FACTORY WELD — 5" (13 cm) (135 cm) (4 cm) FIELD WELD (4 cm) G" (15 cm) 1-1/2" —a 1-1/2" (4 cm) (4 cm) FACTORY FIELD WELD WELD _ 3 "--->-I (8 cm) (156cm) 1-1/2" 1-1/2" (4 cm) (4 cm) FIELD FIELD WELD WELD 311� (8 cm) LAP STYLE "A" OPEN LAP STYLE "B" OPEN LAP STYLE "C" CLOSED LAP STYLE "D" CLOSED GENERAL REFERENCE: FIR MAGNUM PLATES &FASTENERS r "FTR Gs06" LAP STYLE AND POSITION APPLICABLE SYSTEMS: Oak "FTR MA06" REVISES DETAIL ISSUE DATE DRAWING NUMBER INTELLIGENT ROOFING SOLUTIONS ALL PREVIOUS 03-01-07 FTR-DLAP LA —11-1/2" s , , , , , , , 04 5" WELD / LAP LINE 1 , , , , , , LL , s , W ' , , , m , LL � UNDERLYING (BOTTOM) MEMBRANE EDGE , -`--< INCREMENTAL MARKING ' 6" O.C. , , , , W , LL , GENERAL REFERENCE: "FTR G506" FTR MAGNUM PLATES &FASTENERS APPLICABLE SYSTEMS: LAP /PLACEMENT "FTR fuJA06" REVISES DETAIL ISSUE DATE DRAWING NUMBER ALL PREVIOUS 03-01-07 FTR-DLAPZ INTELLIGENT ROOFING SOLUTIONS FTR #101 SEALANT (TOOLED) #101 SEALANT (TOOLED) FTR ALUMINUM TERMINATION BAR, FASTEN WITH APPROVED FASTENER METAL COUNTER FLASHING s OYO Me.5 14- 1'ae, pew! 1400D BLOCKING ATTACHED @ 250 LBF/FT OR FTR-FB MEMBRANE a 0�/J7^1,� INSULATION ATTACHED PER SPECIFICATION REQUIREMENTS X, GENERAL REFERENCE: • "FTR G506" n TYPICAL UDRIZONTAL n MEMBRANE BLOCKING WALL FLASHING W/ SAWCUT REGLET APPLICABLE SYSTEMS: REVISES DETAIL ISSUE DATE DRAWING NUMBER "FTR MA06" F--rR BA0611 ALL PREVIOUS 03-01-07 FTR-DW1 i NON -LIFTABLE z 00 ROOF TOP UNIT OR SKYLIGHT _6 1 oT I'-S fPDM WASHERED FASTENER AS REQUIRED FTR #101 SEALANT BEHIND TOP OF FLASHING METAL COUNTERFLASHING, FASTEN WITH EPDM WASHERED FASTENERS AT 12" O.C. FLASHING (FULLY ADHERED) GALVANIZED ANNULAR RING SHANK NAIL AT 3" O.C. ROOF TOP UNIT OR SKYLIGHT EPDM WASHERED FASTENER AS REQUIRED FTR MEMBRANE FLASHING FTR #201 OR #190 ADHESIVE ' GALVANIZED ANNULAR RING SHANK NAIL AT 6" O.C. INSULATION ATTACHED OR — ADHERED PER SPECIFICATION �1 'MOOD BLOCKING/CURB CONSTRUCTION ATTACHED AT 250 LBF/FT GENERAL REFERENCE: TYPICAL WOOD CURB "FTR GS06" OR SKYLIGHT FLASHING APPLICABLE SYSTEMS: "FTR MA06" REVISES DETAIL ISSUE DATE DRAWING NUMBER INTELLIGENT "FTR AD06" ROOFING SOLUTIONS "FTR sa06" ALL PREVIOUS 03-01-07 FTR-DP1 NON -LIFTABLE FTR #101 SEALANT BEHIND TOP OF FLASHING a CAL UNIT METAL COUNTERFLASHING, FASTEN W/ EPDM WASHERED FASTENERS AT 12" O.C. FTR FLASHING (FULLY ADHERED) GALVANIZED ANNULAR RING SHANK NAIL AT 3" O.C. ROOF TOP UNIT OR SKYLIGHT EPDM WASHERED FASTENER 8" MIN ® AS REQUIRED FTR MEMBRANE FLASHING ADHERED IN FTR #201 OR #190 ADHESIVE PREMOLDED CORNER ® ® /--HOT AIR WELD 1. WOOD BLOCKING/CURB CONSTRUCTION ATTACHED AT 250 LBF/FT INSULATION ATTACHED PER - SPECIFICATION REQUIREMENTS FTR OR FTR-FB MEMBRANE GALVANIZED ANNULAR RING SHANK NAIL AT 6" O.C. GENERAL REFERENCE: TYPICAL WOOD CURB "FTR G506" OR SKYLIGHT FLASHING APPLICABLE SYSTEMS: "FTR MA06" REVISES DETAIL ISSUE DATE DRAWING NUMBER '�7R BA006" ALL PREVIOUS 03-01-07 1 FTR-DP11 . INTELLIGENT ROOFING SOLUTIONS GENERAL REFERENCE: "FTR GS06" PRE -MOLDED PIPE FLASHING APPLICABLE SYSTEMS: "FTR MAO 6 " REVISES DETAIL ISSUE DATE DRAWING NUMBER "FTR D006" ALL PREVIOUS 03-01-07 1 FTR-DP3 [940rrml Y 2'-C FRAME OPENING LENGTH [762mm) r---------------------------- ---------- - - ------------------- 1 I ' 1 C `$ J 2 II 1 I 111 ' I 1 1 II '� I I � ' I L--—---- --------------------------------- -- ------------- -----------J MIAMI-DADE COUNTY PRODUCT CONTROL APPROVED N.O.A. #11-0722.10 EXPIRES 12/02/14 FILE CLASSIFICATION: HIGH VELOCITY HURRICANE ZONE IMPACT RATE: LARGE AND SMALL MISSILE IMPACT FLORIDA PRODUCT APPROVAL # FL15110 TYPE: S-20 AND S-50 ONLY 12 1 [305mm] 1] 7 [187mm] 2 SPACES !T O.C. [356mm] —2 1/4" TIP. ALL AROUND [57mm] 7/16- [11] DIA ANCI (ANCHOR BOLTS BY ANCHOR HOLE L, mmwm Is THE PROPFATY Cr we m= CON.I_ All 90 mCOWMTES INFORYAW" WCH 5PRDPPETMY. @UCARMI MD/OR PUm1C 0151RIBU110N Ol M1mE di fPXU2z PART 6 E TAMY PROHIWTDI WINOUi THE PPoOR wmm cws:,T OF w 9= coImARY. THE 3] [57mm] AnaR cowrmw HOW REM10 THE PROPEmY OF 1xE z% co1BAHY. Am Flans RESEnvm. [89mm] SECTION SPEC/F/CAT/ONS 1. FRAME W/ CAPFLASHING (CORNERS FULL WELDED) S-20 - 14 GAUGE P.B. GALV. STEEL S-40 - 14 GAUGE P.B. GALV. STEEL S-50 - 11 GAUGE ALUMINUM S-90 - 14 GAUGE TYPE 304 STAINLESS STEEL 2. PINTLE HINGE 3. GASKET (ALL AROUND COVER) 4. COVER GAUGE S-20 - 14 GAUGE P.B. GALV. STEEL S-40 - 11 GAUGE ALUMINUM S-50 - 11 GAUGE ALUMINUM S-90 - 14 GAUGE TYPE 304 STAINLESS STEEL 5. COVER LINER S-20 - 22 GAUGE P.B. GALV, STEEL S-40 - 18 GAUGE ALUMINUM S-50 - 1B GAUGE ALUMINUM S-90 - 22 GAUGE TYPE 304 STAINLESS STEEL 6. LIFTING MECHANISM WITH REINFORCED COMPOSITE TUBES AND COMPRESSIONS SPRINGS 7. 1" RIGID FIBERBOARD INSULATION 8. SLAM LATCH 9. INSIDE AND OUTSIDE HANDLES W/ PADLOCK HASPS 10. ARM GUIDE BRACKET 11. 1" THICK FIBERGLASS COVER INSULATION 12. HOLD OPEN ARM W/ RED VINYL GRIP 13. NEOPRENE GASKET 14. LOCK STRIKE & PADLOCK HASP 15. BILCLIP" FLASHING SYSTEM SHOP FINISH: STEEL: RED OXIDE PRIMER ALUMINUM: MILL FINISH HARDWARE: ZINC PLATED & CHROMATE SEALED (WUW OTHERNISE SPECIFIED) STAINLESS STEEL• BEADBLAST FINISH TYPE 316 S/S HARDWARE THIS PRODUCT MAY BE INSTALLED ON EITHER A FLAT OR SLOPING ROOF. WHEN INSTALLED ON A SLOPE, THE HINGE SIDE MUST RUN PARALLEL WITH THE SLOPE. IF SLOPE EXCEEDS 30', ADVISE FACTORY FOR MODIFICATION. THE BILCO COMPANY SINGLE LEAF ROOF SCUTTLE TYPE S SIZE 3'-0" x 2'-6" 01Y TYPE VADTH x LENGTH METAL ® S•20 STEEL COVERiSTEEL FRAME CJ S-40 ALUM, COVERISTEEL FRAME [� S-50 ALUM. COVERIALUM.FRAME o S-90 STLS STL COVERISTLS STL FW 151 E TI AND PUI# NP MaTTEN WN5tm R 1NL WLW R.IPMT. Im 9iaWAi10N CaaAM HMN MANS THE PPCPVM OF TFIE fiILCO COMPANY. ALL PoC M RMVW. SPEC/F/CA 17ONS 1. Pull up loop 2. Release rod w/ vinyl lift handle 3. Lock up bracket 4. Balancing spring E 5. Square tubing rE 6. Adjustable mounting channel 7. Clamp bracket 8. Stainless steel mounting bolts (3/8-16 x 2") NOTES: 1. The Bilco LadderUP safety post is furnished completely assembled ready to mount on rear of ladder with clamp brackets on climbing side. Ladder must be structurally sound and securely anchored. 2.On hollow round rung ladders insert solid round bar (same length as'rung) into the tap two rungs to provide additional strength and prevent crushing of the rung when the LadderUP Is fastened. 3. Adjustable mounting fits ladders with rung spacing up to about 14" [355mm] center to center. 4• Clamp bracket may be reversed to accommodate rung sizes of 3/4" [19mm] to 1 1/4" [32mm] with standard 2" [51mm] bolts furnished. Larger rungs will require longer bolts. ROOF SC(177ZZ' NOT /NCLUDEO N' THE BILCO COMPANY New Haven. Connecticut 06505 LADDER UP SAFETY POST � QTY TYPE a MATERIALIFINISH LU•1 STEELIYELLOW ENAMEL C] LU•2 STEEL/HOT DIPPED GALV. LU•3 STAINLESS STEEL a [� LU-4 ALUMINUMIMILL FINISH Jo • FIBERCLAD METAL 4" WIDE FLASHING STRIP, HEAT WELDED IN PLACE 4„ ,:....2' WIDE WIDE ALUMINUM TAPE OVER JOINT - 1/4" GAP JOINT TREATMENT AT EDGE METAL INTELLIGENT ROOFING SOLUTIONS FIBERCLAD METAL GALVANIZED ANNULAR RING SHANK NAIL AT 6° O.C. FTR MEMBRANE FLASHING STRIP HOT AIR WELD 114Jv Lmllv1Y ni ln�jl"u 1 "x SPECIFICATION REQUIREMENTS WOOD BLOCKING By Ott erg ATTACHED @ 250 LBF/FT BUTYL SEALING TAPE CONTINUOUS GALVANIZED METAL CLEAT FASTEN WITH GALVANIZED ANNULAR RING SHANK NAILS AT 3" O.C. GENERAL REFERENCE: "FTR GS06" TYPICAL EDGE FLASHING APPLICABLE SYSTEMS: "FTR P4A06" REVISES DETAIL ISSUE DATE DRAWING NUMBER "FTR A©06" ALL PREVIOUS 03-01-07 FTR-DE1 DRAIN ASSEMBLY WITH CLAMPING RING (BY OTHERS) INTELLIGENT ROOFING SOLUTIONS FTR #101 SEALANT FTR NON -REINFORCED MEMBRANE FLASHING TAPERED INSULATION ATTACHED @ MINIMUM OF 2 FASTENERS PER BOARD FTR MEMBRANE HOT AIR WELD--�� FTR FASTENER(S) & - STRESS PLATE(S) 12" O.C. AROUND SUMP AREA FIELD TAPER SUMP TO PROVIDE A SMOOTH TRANSITION AS REQ. EXTEND FTR NON -REINFORCED MINIMUM OF 1/2" BEYOND INSIDE OF CLAMPING RING GENERAL REFERENCE: "FTR GS06" APPLICABLE SYSTEMS: "FTR MA06" "FTR AD06" "FTR BA06" NOTE; USE TAPERED ROOF INSULATION (EDGE STRIPS) TO CREATE DRAIN SUMP. IF TOTAL INSULATION THICKNESS IS LESS THAN OR EQUAL TO 1 1/2 IN., TAPER 12 IN. FROM THE DRAIN CENTER. IF TOTAL INSULATION THICKNESS IS GREATER THAN 1 1/2 IN., TAPER 18 IN. FROM DRAIN CENTER, TYPICAL DRAIN FLASHING REVISES DETAIL ISSUE DATE DRAWING NUMBER ALL PREVIOUS 03-01-07 FTR-DDl INTELLIGENT ROOFING SOLUTIONS 30" �- i uvi nin tvLLu Vlytn�u,j GENERAL REFERENCE: "FTR GS06" FTR PROTECTION PAD & WALK WAY MATERIALS APPLICABLE SYSTEMS: " FTR mA0 6 " REVISES DETAIL ISSUE DATE DRAWING NUMBER "FTR BA06" ALL PREVIOUS 03-01-07 FTR-DM1