HomeMy WebLinkAboutPOLYGLASS SAV-SAP 2021 1/11/2021 Florida Building Code Online
Business & Professional Regulation
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
a-ica
(.4-
Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL1654-R27
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/07/2022
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL1654 R27 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D4601 2012
ASTM D4897 2009
ASTM D6162 2015
ASTM D6163 2015
hfps://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhNlxQbXaKmD3x9HjyOAYxuQ%3d%3d 1/2
1/11/2021 Florida Building Code Online
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
ASTM G155 2013
FM 4470 2016
FM 4474 2011
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/02/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
Summary of Products
FL# Model,Number or Name Description
1654.1 Polyglass Modified Bitumen Roof SBS and APP modified bitumen roof systems
'Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL1654 R27 II 2020 09 30 FINAL Al ER PG MODBIT FL1654-
Approved for use outside HVHZ:Yes R27.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this application relates Evaluation Reports
to one particular assembly over concrete deck. Refer to the FL1654 R27 AE 2020 09 30 FINAL ER PG MODBIT FL1654-
ER Appendix for other systems and deck types. 2.) Refer to R27.pdf
ER,Section 5 for other Limits of Use. 3.) Refer to FL16717 Created by Independent Third Party: Yes
for HVHZ jurisdictions.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copright 2007-2013 State of Florida. ::Privacv Statement::Accessibiliri Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
hfps://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhNlxQbXaKmD3x9HjyOAYxuQ%3d%3d 2/2
MEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
04 (203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONP•R
Polyglass USA, Inc. Evaluation Report P9290.02.08-1125
1111 West Newport Center Drive FL1654-1127
Deerfield Beach, FL 33442 Date of Issuance:02/11/2008
(954)233-1330 Revision 25:09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7'Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5, plus a 94-page Appendix.
Prepared by:
5,n
Robert J.M. Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCAANE1983 _+.
4 % Nieminen,P.E.on 09/30/2020.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018,NEMO ETC,LLC
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: Polyglass Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
STANDARDS:2.
Section Pro a Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2012
1504.6 Accelerated weathering ASTM G155 2013
1504.7 Impact resistance FM 4470,Section 4.6 2016
1507.10.2 Material standard ASTM D4601 2012
1507.10.2 Material standard ASTM D4897 2009
1507.11.2 Material standard ASTM D6162 2015
1507.11.2 Material standard ASTM D6163 2015
1507.11.2 Material standard ASTM D6164 2011
1507.11.2 Material standard ASTM D6222 2011
1507.11.2 Material standard ASTM D6509 2015
3. REFERENCES:
gnt4y Exam Reference Date Ent! Exam Reference Date
ERD(TST6049) Physicals P10490.10.08-2 10/30/2008 FM(TST1867) FM 4470 3006115 05/02/2001
ERD(TST6049) FM 4470/4474 P13760.09.09 09/10/2009 FM(TST1867) FM 4470 3012321 07/29/2002
ERD(TST6049) FM 4470/4474 P13770.09.09 09/10/2009 FM(TST1867) FM 4470 3014692 08/05/2003
ERD(TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 FM(TST1867) FM 4470 3014751 08/27/2003
ERD(TST6049) FM 4470/4474 P30550.12.09 12/02/2009 FM(TST1867) FM 4470 3007170 01/13/2004
ERD(TST6049) Physicals P33960.12.10 12/30/2010 FM(TST1867) FM 4470 3019317 06/30/2004
ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM(TST1867) FM 4470 3020703 07/30/2004
ERD(TST6049) Physicals P37590.03.13-3A 03/06/2013 FM(TST1867) FM 4470/4474 3018332 01/31/2006
ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM(TST1867) FM 4470/4474 3023368 03/20/2006
ERD(TST6049) Physicals P37590.03.13-1-R1 06/26/2013 FM(TST1867) FM 4470/4474 3024594 05/23/2006
ERD(TST6049) Physicals P37590.03.13-2-R1 07/01/2013 FM(TST1867) FM 4470/4474 3023458 07/18/2006
ERD(TST6049) Physicals P37590.07.13-2 07/01/2013 FM(TST1867) FM 4470/4474 3030668 09/12/2007
ERD(T5T6049) Physicals P37590.03.13-5-111 07/01/2013 FM(TST1867) FM 4470/4474 3032172 06/12/2009
ERD(TST6049) Physicals P37590.07.13-1 07/02/2013 FM(TST1867) FM 4470/4474 3049631 04/21/2014
ERD(TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM(TST1867) FM 4470/4474 3057029 02/02/2017
ERD(TST6049) Physicals P45940.09.13 09/04/2013 NEMO(TST6049) Criticality 4S-PLYG-18-001.06.18 06/23/2018
ERD(TST6049) Physicals P44370.10.13 10/04/2013 NEMO(TST6049) FM 4474 4L-PLYG-18-003.08.18 08/21/2018
ERD(TST6049) Physicals P39520.09.14-2 09/11/2014 NEMO(TST6049) Criticality 4S-PLYG-18-001.10.18 10/03/2018
ERD(TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 NEMO(TST6049) ASTM D4897 4S-PLYG-18-002.11.18-2 11/16/2018
ERD(TST6049) Physicals P454405C.03.15-1 03/31/2015 NEMO(TST6049) ASTM D6164 45-PLYG-18-002.11.18-3 11/28/2018
ERD(TST6049) Physicals SC5170.05.15 05/08/2015 NEMO(TST6049) FM 4474 4L-PLYG-18-003.11.18 11/28/2018
ERD(TST6049) FM 4474 SC8085.05.15 05/19/2015 NEMO(TST6049) FM 4474 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST6049) Physicals SC5170.12.15 12/29/2015 NEMO(TST6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019
ERD(TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO(TST6049) ASTM D6162 4S-PLYG-18-002.01.19-B 01/25/2019
ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO(TST6049) FM 4474 4L-PLYG-18-003.04.19-A 04/08/2019
ERD(TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO(TST6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST6049) FM 4470/4474 PLYG-SC10815.07.16-RI 09/23/2016 NEMO(TST6049) ASTM D6222 45-PLYG-18-002.05.19-D 05/20/2019
ERD(TST6049) UL 1897 PLYG-SC12025.10.16 10/12/2016 NEMO(TST6049) ASTM D6163 4S-PLYG-18-002.05.19-H 05/20/2019
ERD(TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 NEMO(TST6049) ASTM D6164 4S-PLYG-18-002.05.19-N 05/31/2019
ERD(TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 NEMO(TST6049) Criticality 4S-PLYG-18-001.06.19.A 07/17/2019
ERD(TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 NEMO(TST6049) ASTM D6164 4S-PLYG-18-002.09.19-1 09/06/2019
ERD(TST11294) FM 4470/4474 PLYG-CrL13945.05.17-1 05/30/2017 NEMO(TST6049) ASTM D6164 4S-PLYG-18-002.09.19-J 09/06/2019
ERD(TST11294) FM 4470/4474 PLYG-CFL13945.05.17-3 05/30/2017 NEMO(TST6049) FM 4474 4a-PLYG-20-LSWUS-01.A 08/28/2020
ERD(TST6049) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI(TST5878) Physicals PUSA-062-02-01 12/04/2007
ERD(TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/11/2017 PRI(TST5878) Physicals PUSA-061-02-02 01/28/2008
FM(TST1867) FM 4470 2W7A7.AM 08/04/1994 PRI(TST5878) Physicals PUSA-064-02-02 02/27/2008
FM(TST1867) FM 4470 OD3A3.AM 04/04/1997 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008
FM(TST1867) FM 4470 2DOAO.AM 12/23/1998 PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017
NEMO ETC,LLC Evaluation Report P9290.02.08-R25
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL1654-1127
Polyglass Modified Bitumen Roof Systems Revision 25:09/30/2020
Page 2 of 5
ONEMOjetc.
Ent Exam Reference Date Enti Exam Reference Date
FM(TST1867) FM 4470 2D5A9.AM 06/22/1999 PRI(TST5878) TAS 114 PUSA-188-02-02 02/08/2017
FM(TST1867) FM 4470 3006646 01/04/2000 PRI(TST5878) TAS 114 PUSA-188-02-03 02/08/2017
FM(TST1867) FM 4470 3001334 01/25/2000 PRI(TST5878) TAS 114 PUSA-202-02-01 05/17/2017
FM(TST1867) FM 4470 3001334 02/15/2000 PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017
FM(TST1867) FM 4470 3000857 01/12/2000 M-D(CER1592) HVHZ Various NOAs Various
FM(TST1867) FM 4470 3004091 01/12/2000 M-D(CER1592) Prop.for Rev. 10-0823 10/12/2010
UL(QUA9625) Quality Control Service Confirm 09/13/2018
PRODUCT4. DESCRIPTION:
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass
USA,Inc.published installation instructions and the Limitations/Conditions of Use herein.
TABLE 1:ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS
Type Product Material Standard Plant(s)
Reference Type Grade
Polyglass G2 Base ASTM D4601 II N/A AL
Polyflex SA Base ASTM D4601 II N/A FL
Base Sheets Elastobase SA ASTM D4601 II N/A PA
Elastovent ASTM D4897 N/A N/A PA
Polyglass Base ASTM D6509 N/A N/A FL
APP,Smooth-Surface Polybond ASTM D6222 I S FL
Membranes Polyflex ASTM D6222 1 S FL
Polykool ASTM D6222 I S FL
Polybond G ASTM D6222 I G FL
Polyflex G ASTM D6222 I G FL
Polyflex G FR ASTM D6222 I G FL
APP,Granule-Surface Polyfresko G ASTM D6222 I G NV
Membranes Polyfresko G FR ASTM D6222 I G NV
Polyflex SA P ASTM D6222 I G FL,TX
Polyflex SA P FR ASTM D6222 I G TX
Polyfresko G SA ASTM D6222 I G NV
Polyfresko G SA FR ASTM D6222 I G NV
Elastoshield HT ASTM D6162 III S FL
Elastobase ASTM D6163 I S FL
Elastoflex V ASTM D6163 I S FL
Elastoflex SA V ASTM D6163 I S FL,PA,TX
Elastoflex SA V FR ASTM D6163 I S FL,PA,TX
SBS,Smooth-Surface Elastoflex SA V Plus ASTM D6163 I S FL,TX
Membranes Elastoflex SA V Plus FR ASTM D6163 I S FL,TX
Elastobase P ASTM D6164 I S FL,TX
Elastoflex SA Base HD ASTM D6164 1 S PA,TX
Elastoflex S6 ASTM D6164 1 5 FL
Elastoflex S6 HP ASTM D6164 11 S NV
Polyreflect ASTM D6164 I S FL
Elastoshield HT G ASTM D6162 III G FL
Elastoshield HT G FR ASTM D6162 III G FL
Elastoflex V G ASTM D6163 I G FL,PA
Elastoflex V G FR ASTM D6163 I G FL,PA
SBS,Granule Surface Elastoflex S6 G ASTM D6164 I G FL,PA
Membranes Elastoflex S6 G FR ASTM D6164 I G FL
Elastoshield TS G ASTM D6164 I G FL,TX
Elastoshield TS G FR ASTM D6164 I G FL,TX
Elastoflex SA P ASTM D6164 I G FL,TX
Elastoflex SA P FR ASTM D6164 I G FL,TX
NEMO ETC,LLC Evaluation Report P9290.02.08-R25
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL1654-R27
Polyglass Modified Bitumen Roof Systems Revision 25:09/30/2020
Page 3 of 5
ONEMOletc.
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade
Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning
the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for low-slope roofs.
5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing
deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface
conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-
1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on
mock-ups of the proposed new roof assembly.
5.6.3 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.
5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance.
5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with
FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.
Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29(February 2020)for Zone 2/3 enhancements.
5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is
permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 614320-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.
NEMO ETC,LLC Evaluation Report P9290.02.08-R25
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL1654-R27
Polyglass Modified Bitumen Roof Systems Revision 25:09/30/2020
Page 4 of 5
p n Z CC CC C CC C C C CC CC CC CC CC N a �
O r
000 �j O N N N N ? N N ? N N N N N N 'D O
d m f+ N N r•-� O N f.. p �••� �•-� �-+ �••� O O
Zm co %D 0o V Ol to In A H W N F-` O to w =
1 9
r
O D r 7 3 3 7 m 7 7 m 7 7 3 7 7 7 m O V D =
rn n n n _. n n 3 n n 3 n n n n n x :p N v G1 G
K S 7 S 7 S 7 S 7 fA S 7 S 7 N =r 7 S 7 S 7 S 7 S 7 'O
a v ' v ' N 00nd ?P* x"
r •< ul to •< to < to 1 •c to •< to to to to to •< toSi 5 D Qm
1F W o o
a) O W O W O W O W Of wO w OW O W O W r<
0
OW O
O O O O rNON mO O ON ON O N
m
O p. Q n CL T O_ rL T Q 0. d Q f1 O V
3k O O w
W S 2
N m m
A O v v Z 7D oD O -0 T Z Z
"O Imo-` j G) 'd m G) 0 O CD CD< ev C) CD w ci M a .*
W ca O 7 O 7 7 V 7 W 7 O
O m v v O V i
V C)i m Ll Gl m Cif ,p Ll
lAfi 0 � C) 0 y C In 0
O j O O O O
Z T Z Z j T Z j T Z 3 T Z Z "O O
OG O O O O O O N In
7 O 7 7 O 7 O 7 O 7 7 n w
m -p o fD m -o p fD -0 o f° -p o m m m Q
o d o d o d o o -
n n n O_ n CL n d 3
n
m p m o m o o
p � O j O � O j tD
fD N fD lL fD N fD lL n n0
w to a a O
rD n iD n n n
m
O < n0 < O O < S. CL
7 m 7 m 7 m O
,7p m
7 m j m 7 m c K
O Qr d p.
y C c c `t C F O A
S S 5- S 7
�? V p A p A p A O A . S O
H S
m a 7 7 Q 7 Q 7 e,F •
to n Q
Q S S S S m
c. O a 0_ o 0
y; Z CD m m m
ii
N _0 m 0 N •
m
t O 00 00 pH. 0— v
T K
m m m m pICA
0 n d m °
o p CD
° oy ° ° Ln
CD •
Z m m M ro D
x x x x <
H < D D D D o
N N < < < < A •
o •
• D �^ `n `n 7 n
r N O O
Ln
V
a CD m
a 2 O_ O_ •
w O 2 •
Z V. Ln (A to D D -00 m to m m V, to -0 o m A •CC) ca
C N v v H m H twn Ir LP
m F+ • •
D D D D D D z ^ D D D z m^ W
2 2 2 2 2 2 p x x x CD
x m
N
m H to Ln
> m
x D D x D y •
y < « D < <—
m o < v
< c c
O O O O O O D O D O D O D O D O D O
o a v v a a o a
0 0 0 0 0 o v o v o -0 o v o v o v 0
7 '0 7 T 7 T 7
lL N N N N N (U 0l !L N !v D)
w w H to D D
D N D y Dj D N D N D N V
w w 'V T t. N N H
W w N to <
C (A Ln N T
K � � -I � � -i Vf N to In to N
o D D D D D D D D D D D D
7 to to N Ln to to
w co w w w w
m N to to N to In
O
;I
v to to W to D D to Ln to to to to to to to to Vt to
w w w w w w w w w w w w
N twn twn twn twn V -V V, to VI to to to VI to to to to (n
t0 (n to Ll to L, Vf -L, to In
D D D D D D D D D D D D D D D D D D n
> z N D D D D D D D D D D D D y
m
N. � vv vv v � vv vv v �
T -p T V T TT T T TT
'O
OT O
lro Co r
w
W m
O N A 0 In
O tD O O W tD W O V V O N
CD �0 ul V V O O
lD N N O N to O O O O Ln to C) LnN A
A O V .�.