Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-07 14:54:31 Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1 ...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information For:1764 W. MIDWAY ROAD, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh15717 Structure Btuh12244 Ducts Btuh2920 Ducts Btuh3635Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh18637 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh15085 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh1522 Ducts Btuh1114Central vent (0 cfm) Btuh0 CoolingHeating (none)11881188Area (ft²) Equipment latent load Btuh2636 95049504Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh17721 Equiv. AVF (cfm) 3671 Req. total capacity at 0.70 SHR ton1.8 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX160241FAHRI ref Coil ASPT29B14A AHRI ref 201384201Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW5.4 Sensible cooling Btuh16520Heating output Btuh18400 Latent cooling Btuh7080 Temperature rise °F21 Total cooling Btuh23600Actual air flow cfm787 Actual air flow cfm787 Air flow factor cfm/Btuh0.042 Air flow factor cfm/Btuh0.050Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-07 14:54:31Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House LIVING/DINING 2 Exposed wall 150.0 ft 78.0 ft 3 Room height 8.0 ft 8.0 heat/coolft 4 Room dimensions ft612.0x1.0 5 Room area 1188.0 ft²612.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 384 366 1465 801 192 192 769 420 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 6 0 213 209 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 12 0 427 417 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 216 168 673 368 216 168 673 368 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 86.0586.05 48 4 1707 4130 48 4 1707 4130 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 384 307 1230 672 192 151 605 331 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 36 36 1280 1252 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 41 41 446 422 41 41 446 422 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 216 216 865 473 24 24 96 53 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 1188 1188 1064 1901 612 612 548 979 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1188 150 4154 0 612 78 2160 0 6 c) AED excursion 0 104 Envelope loss/gain 13524 10644 7004 6807 12 a) Infiltration 2193 601 1141 312 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13)15717 12244 8144 7119 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 21 16 14 Subtotal 15717 12244 8165 7135 15 Duct loads 19%30%2920 3635 19%30%1517 2118 Total room load 18637 15879 9682 9253 Air required (cfm)Air required (cfm)787 787 409 458 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-07 14:54:31Right-Suite® Universal 2021 21.0.08 RSU08101 Page 2...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 1 BATH 2 Exposed wall 29.0 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x18.0 ft57.0x1.0 5 Room area 198.0 ft²57.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 144 132 529 289 48 42 168 92 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 6 0 213 209 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 12 0 427 417 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 86.0586.05 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 88 88 352 193 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 198 198 177 317 57 57 51 91 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 198 29 803 0 57 6 166 0 6 c) AED excursion -27 -8 Envelope loss/gain 2288 1189 599 383 12 a) Infiltration 424 116 88 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2712 1305 686 407 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 108 66 23 20 14 Subtotal 2820 1371 710 428 15 Duct loads 19%30%524 407 19%30%132 127 Total room load 3344 1778 842 555 Air required (cfm)Air required (cfm)141 88 36 27 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-07 14:54:31Right-Suite® Universal 2021 21.0.08 RSU08101 Page 3...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 KITCHEN 2 Exposed wall 23.0 ft 11.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft10.0x13.0 ft10.0x11.0 5 Room area 130.0 ft²110.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 86.0586.05 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 104 92 368 201 88 64 256 140 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 12 12 427 417 24 24 853 835 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 80 80 320 175 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 130 130 116 208 110 110 99 176 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 130 23 637 0 110 11 305 0 6 c) AED excursion -22 -44 Envelope loss/gain 1869 980 1513 1107 12 a) Infiltration 336 92 161 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13)2205 1072 1674 2151 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 78 48 66 40 14 Subtotal 2283 1120 1740 2191 15 Duct loads 19%30%424 332 19%30%323 650 Total room load 2707 1452 2063 2842 Air required (cfm)Air required (cfm)114 72 87 141 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Feb-07 14:54:31Right-Suite® Universal 2021 21.0.08 RSU08101 Page 4...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name HALL A/C 2 Exposed wall 3.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft3.0x24.0 ft3.0x3.0 5 Room area 72.0 ft²9.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 86.0586.05 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 24 24 96 53 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 72 72 65 115 9 9 8 14 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 72 3 83 0 9 0 0 0 6 c) AED excursion -4 0 Envelope loss/gain 244 164 8 14 12 a) Infiltration 44 12 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)288 176 8 14 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -288 -176 -8 -14 14 Subtotal 0 0 0 0 15 Duct loads 19%30%0 0 19%30%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Bold/italic values have been manually overridden 2022-Feb-07 14:54:31 Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1 ...Documents\Wrightsoft HVAC\1764 W MIDWAY RD..rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information For: 1764 W. MIDWAY ROAD, FT. PIERCE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.373in/100ft0.373 Actual air flow cfm787cfm787 Total effective length (TEL) ft134 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 95.03.6VlFx0x04.00.5072736842hBATH st1115.014.0VlFx0x07.00.388881413344hBEDROOM 1 st1115.018.9VlFx0x07.00.373721142707hBEDROOM 2 st1115.018.5VlFx0x07.00.375141872842cKITCHEN 95.08.1VlFx0x07.00.4851531363084cLIVING/DINING 95.011.4VlFx0x07.00.4701531363084cLIVING/DINING-A 95.018.1VlFx0x07.00.4421531363084cLIVING/DINING-B Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 342 301 0.373 775 9.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 2720 306 0 0 0 0 x0 0 VlFx rb2 0x 2230 294 0 0 0 0 x0 0 VlFx rb3 0x 2910 188 0 0 0 0 x0 0 VlFx