HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1764 W MIDWAY ROAD Builder Name:
Street:1764 W. MIDWAY ROAD Permit Office:
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner:Jurisdiction:
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing Addition
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 2
5. Is this a worst case?No
6. Conditioned floor area above grade (ft²)1188
Conditioned floor area below grade (ft²)0
7. Windows(102.0 sqft.) Description Area
a. U-Factor:Sgl, U=0.65 102.00 ft2
S H G C :SHGC=0.51
b. U-Factor:N/A f t2
S H G C :
c. U-Factor:N/A f t2
S H G C :
Area Weighted Average Overhang Depth: 2.000 ft
Area Weighted Average SHGC:0.510
8. Skylights Description Area
U - F a c t o r : ( A V G ) N/A N/A ft2
S H G C ( A V G ) : N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 1188.00 f t2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(1200.0 sqft.) I n s u l a t i o n Area
a. Concrete Block - Int Insul, ExteriorR=4.1 1200.00 ft2
b. N/A R = f t2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(1188.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented)R=30.0 1188.00 ft2
b. N/A R= f t2
c. N/A R= f t2
12. Ducts, location & insulation level R ft2
a. a. Sup: Attic, Ret: Attic, AH: A/C 6 125
b .
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 23.6 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Strip Heat 17.0 COP:1.00
15. Hot Water Systems -
a. Electric Cap: 50 gallons
EF: 0.950
b. Conservation features
None
16. Credits None
Glass/Floor Area:0.086 Total Proposed Modified Loads: 35.37
Total Baseline Loads: 36.19 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code.calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: _________________________________ Before construction is completed
this building will be inspected for
DATE: _________________________________________ compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________
DATE: _________________________________________ DATE: _________________________________________
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Proposed Qn of 0.080 exceeds the performance method default limit of 0.08
and therefore does not require duct testing. R405 .2.3
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
2-7-2022
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:1764 W MIDWAY ROAD Address type:Street Address
Building Type:Bedrooms:Lot #:User 2 ---
Owner:Conditioned Area:Block/SubDivision:1188 ---
Total Stories:PlatBook:1 ---
Builder Name:Worst Case:Street:No 1764 W. MIDWAY ROAD
Permit Office:Rotate Angle:County:0 St. Lucie
Jurisdiction:Cross Ventilation:City, State, Zip:No FT. PIERCE,
Family Type:Whole House Fan: Detached No F L ,
New/Existing:Terrain: Addition Suburban
Year Construct:Shielding: Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range
___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
___ 1 Entire House 1188 9504
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
___ 1 LIVING/DINING 612 4896 No 0 Yes Yes Yes
___ 2 BEDROOM 1 198 1584 No 0 1 Yes Yes Yes
___ 3 BATH 57 456 No 0 Yes Yes Yes
___ 4 BEDROOM 2 130 1040 No 0 1 Yes Yes Yes
___ 5 KITCHEN 110 880 Yes 0 Yes Yes Yes
___ 6 HALL 72 576 No 0 Yes Yes Yes
___ 7 A/C 9 72 No 0 No Yes Yes
FLOORS (Total Exposed Area = 1188 sq.ft.)
#Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 1 Slab-On-Grade Edge Ins LIVING/DINING 78 0 612 ft 0.473 ---0.00 1.00 0.00
___ 2 Slab-On-Grade Edge Ins BEDROOM 1 29 0 198 ft 0.473 ---0.00 1.00 0.00
___ 3 Slab-On-Grade Edge Ins BATH 6 0 57 ft 0.473 ---0.00 1.00 0.00
___ 4 Slab-On-Grade Edge Ins BEDROOM 2 23 0 130 ft 0.473 ---0.00 1.00 0.00
___ 5 Slab-On-Grade Edge Ins KITCHEN 11 0 110 ft 0.473 ---0.00 1.00 0.00
___ 6 Slab-On-Grade Edge Ins HALL 3 0 72 ft 0.473 ---0.00 1.00 0.00
___ 7 Slab-On-Grade Edge Ins A/C 1 0 9 ft 0.473 ---0.00 1.00 0.00
2/7/2022 2:57:18 PM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch
#Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg)
___ 1 Hip Composition shingles 1252 ft²0 ft²Medium N 0.6 No 0.6 No 0 18.43
ATTIC
#Type Ventilation Vent Ratio (1 in)Area RBS IRCC
___ 1 Full attic Vented 150 1188 ft²N N
CEILING (Total Exposed Area = 1188 sq.ft.)
#Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type
___ 1 Under Attic(Vented)LIVING/DINING 30.0 Blown 612.0ft²0.053 0.10 Wood
___ 2 Under Attic(Vented)BEDROOM 1 30.0 Blown 198.0ft²0.053 0.10 Wood
___ 3 Under Attic(Vented)BATH 30.0 Blown 57.0ft²0.053 0.10 Wood
___ 4 Under Attic(Vented)BEDROOM 2 30.0 Blown 130.0ft²0.053 0.10 Wood
___ 5 Under Attic(Vented)KITCHEN 30.0 Blown 110.0ft²0.053 0.10 Wood
___ 6 Under Attic(Vented)HALL 30.0 Blown 72.0ft²0.053 0.10 Wood
___ 7 Under Attic(Vented)A/C 30.0 Blown 9.0ft²0.053 0.10 Wood
WALLS (Total Exposed Area = 1200 sq.ft.)
Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below
#Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade
___ 1 NE Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.40 0 %
___ 2 SE Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.40 0 %
___ 3 SW Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.40 0 %
___ 4 NW Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 27.0 0 8.0 0 216.0 0.149 0 0 0.40 0 %
___ 5 SE Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.40 0 %
___ 6 SW Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 18.0 0 8.0 0 144.0 0.149 0 0 0.40 0 %
___ 7 SW Exterior Conc. Blk - Int Ins BATH 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.40 0 %
___ 8 NE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.40 0 %
___ 9 SE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.40 0 %
___ 10 NE Exterior Conc. Blk - Int Ins KITCHEN 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.40 0 %
___ 11 SE Exterior Conc. Blk - Int Ins HALL 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.40 0 %
DOORS (Total Exposed Area = 40 sq.ft.)
Width Height
#Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area
___ 1 NE Insulated LIVING/DINING None 0.28 6.00 0 6.00 8 40.0ft²
WINDOWS (Total Exposed Area = 102 sq.ft.)
Wall -----Overhang-----
#Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
___ 1 NW 4 Metal Single (Clear)Yes 0.65 0.51 N N 48.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 2 SW 6 Metal Single (Clear)Yes 0.65 0.51 N N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 3 SW 7 Metal Single (Clear)Yes 0.65 0.51 N N 6.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 4 NE 8 Metal Single (Clear)Yes 0.65 0.51 N N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 5 NE 10 Metal Single (Clear)Yes 0.65 0.51 N N 24.0ft²2.0 ft 0 in 1.0 ft 4 in None None
2/7/2022 2:57:18 PM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
#Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)
___ 1 Wholehouse Proposed ACH(50)0.00025 792 43.45 81.58 0.0902 5.0 All
MASS
#Mass Type Area Thickness Furniture Fraction Space
___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIVING/DINING
___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 1
___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH
___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2
___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN
___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL
___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 A/C
HEATING SYSTEM
#System Type/Fl. Addition Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block
kBtu/hr Entry Power Volt Current
___ 1 Electric Strip Heat/Existing/co None COP: 1.00 17.0 0.00 0.00 0.00 sys#1 1
COOLING SYSTEM
#System Type/Fl. Addition Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
___ 1 Central Unit/Existing/co Split/Single SEER:16.0 23.6 708 0.70 sys#1 1
HOT WATER SYSTEM
#System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length
___ 1 Electric None A/C 0.95 (0.93)50.00 gal 61 gal 120 deg Standard None 79
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
___ 1 No NA NA NA No NA NA NA None
DUCTS
Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC #
#Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
___ 1 Attic 6.0 125 ft²Attic 6.0 65 ft²Proposed Qn A/C ------0.08 0.50 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans: N
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec
2/7/2022 2:57:18 PM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES(Continued)
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
___ Heating (WD)AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
___ Heating (WEH)AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5
CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name:1764 W MIDWAY ROAD Builder Name:
Street:1764 W. MIDWAY ROAD Permit Office:
City, State, Zip:FT. PIERCE, FL, Permit Number:
Owner:Jurisdiction:
Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2)
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall
requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed.a material having a thermal resistance of R-3 per
Knee walls shall be sealed.inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/door jambs and framing, and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation.maintain permanent contact with the underside of
above-garage subfloor decking, or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors)of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls.
Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and
conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall
on exterior wall and tubs shall separate them from the showers and tubs.be insulated.
Electrical/phone box The air barrier shall be installed behind electrical or
on exterior walls communication boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor, wall covering
or ceiling penetrated by the boot.
Concealed When required to be sealed, concealed fire sprinklers shall only
sprinklers be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2/7/2022 2:57:18 PM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1764 W. MIDWAY ROAD,FT. PIERCE,FL,
1. New construction or existing Addition
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 2
5. Is this a worst case?No
6. Conditioned floor area above grade (ft²)1188
Conditioned floor area below grade (ft²)0
7. Windows**Description Area
a. U-Factor:Sgl, U=0.65 102.00 ft2
S H G C :SHGC=0.51
b. U-Factor:N/A f t2
S H G C :
c. U-Factor:N/A f t2
S H G C :
Area Weighted Average Overhang Depth:2.000 ft
Area Weighted Average SHGC:0.510
8. Skylights Description Area
U - F a c t o r : ( A V G )N/A N/A ft2
S H G C ( A V G ) :N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 1188.00 f t2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(1200.0 sqft.) I n s u l a t i o n Area
a. Concrete Block - Int Insul, ExteriorR=4.1 1200.00 ft2
b. N/A R = f t2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(1188.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented)R=30.0 1188.00 ft2
b. N/A R= f t2
c. N/A R= f t2
12. Ducts, location & insulation level R ft2
a. a. Sup: Attic, Ret: Attic, AH: A/C 6 125
b .
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 23.6 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Strip Heat 17.0 COP:1.00
15. Hot Water Systems -
a. Electric Cap: 50 gallons
EF: 0.950
b. Conservation features
None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ___________________________________Date: _________________________
Address of New Home: 1764 W. MIDWAY ROAD City/FL Zip: FT. PIERCE,FL,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1