Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1764 W MIDWAY ROAD Builder Name: Street:1764 W. MIDWAY ROAD Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner:Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)1188 Conditioned floor area below grade (ft²)0 7. Windows(102.0 sqft.) Description Area a. U-Factor:Sgl, U=0.65 102.00 ft2 S H G C :SHGC=0.51 b. U-Factor:N/A f t2 S H G C : c. U-Factor:N/A f t2 S H G C : Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC:0.510 8. Skylights Description Area U - F a c t o r : ( A V G ) N/A N/A ft2 S H G C ( A V G ) : N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1188.00 f t2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(1200.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Int Insul, ExteriorR=4.1 1200.00 ft2 b. N/A R = f t2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(1188.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented)R=30.0 1188.00 ft2 b. N/A R= f t2 c. N/A R= f t2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: A/C 6 125 b . c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 23.6 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Strip Heat 17.0 COP:1.00 15. Hot Water Systems - a. Electric Cap: 50 gallons EF: 0.950 b. Conservation features None 16. Credits None Glass/Floor Area:0.086 Total Proposed Modified Loads: 35.37 Total Baseline Loads: 36.19 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code.calculation indicates compliance with the Florida Energy Code. PREPARED BY: _________________________________ Before construction is completed this building will be inspected for DATE: _________________________________________ compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________ DATE: _________________________________________ DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 2-7-2022 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title:1764 W MIDWAY ROAD Address type:Street Address Building Type:Bedrooms:Lot #:User 2 --- Owner:Conditioned Area:Block/SubDivision:1188 --- Total Stories:PlatBook:1 --- Builder Name:Worst Case:Street:No 1764 W. MIDWAY ROAD Permit Office:Rotate Angle:County:0 St. Lucie Jurisdiction:Cross Ventilation:City, State, Zip:No FT. PIERCE, Family Type:Whole House Fan: Detached No F L , New/Existing:Terrain: Addition Suburban Year Construct:Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range ___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume ___ 1 Entire House 1188 9504 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 LIVING/DINING 612 4896 No 0 Yes Yes Yes ___ 2 BEDROOM 1 198 1584 No 0 1 Yes Yes Yes ___ 3 BATH 57 456 No 0 Yes Yes Yes ___ 4 BEDROOM 2 130 1040 No 0 1 Yes Yes Yes ___ 5 KITCHEN 110 880 Yes 0 Yes Yes Yes ___ 6 HALL 72 576 No 0 Yes Yes Yes ___ 7 A/C 9 72 No 0 No Yes Yes FLOORS (Total Exposed Area = 1188 sq.ft.) #Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 1 Slab-On-Grade Edge Ins LIVING/DINING 78 0 612 ft 0.473 ---0.00 1.00 0.00 ___ 2 Slab-On-Grade Edge Ins BEDROOM 1 29 0 198 ft 0.473 ---0.00 1.00 0.00 ___ 3 Slab-On-Grade Edge Ins BATH 6 0 57 ft 0.473 ---0.00 1.00 0.00 ___ 4 Slab-On-Grade Edge Ins BEDROOM 2 23 0 130 ft 0.473 ---0.00 1.00 0.00 ___ 5 Slab-On-Grade Edge Ins KITCHEN 11 0 110 ft 0.473 ---0.00 1.00 0.00 ___ 6 Slab-On-Grade Edge Ins HALL 3 0 72 ft 0.473 ---0.00 1.00 0.00 ___ 7 Slab-On-Grade Edge Ins A/C 1 0 9 ft 0.473 ---0.00 1.00 0.00 2/7/2022 2:57:18 PM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch #Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg) ___ 1 Hip Composition shingles 1252 ft²0 ft²Medium N 0.6 No 0.6 No 0 18.43 ATTIC #Type Ventilation Vent Ratio (1 in)Area RBS IRCC ___ 1 Full attic Vented 150 1188 ft²N N CEILING (Total Exposed Area = 1188 sq.ft.) #Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type ___ 1 Under Attic(Vented)LIVING/DINING 30.0 Blown 612.0ft²0.053 0.10 Wood ___ 2 Under Attic(Vented)BEDROOM 1 30.0 Blown 198.0ft²0.053 0.10 Wood ___ 3 Under Attic(Vented)BATH 30.0 Blown 57.0ft²0.053 0.10 Wood ___ 4 Under Attic(Vented)BEDROOM 2 30.0 Blown 130.0ft²0.053 0.10 Wood ___ 5 Under Attic(Vented)KITCHEN 30.0 Blown 110.0ft²0.053 0.10 Wood ___ 6 Under Attic(Vented)HALL 30.0 Blown 72.0ft²0.053 0.10 Wood ___ 7 Under Attic(Vented)A/C 30.0 Blown 9.0ft²0.053 0.10 Wood WALLS (Total Exposed Area = 1200 sq.ft.) Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below #Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade ___ 1 NE Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.40 0 % ___ 2 SE Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.40 0 % ___ 3 SW Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.40 0 % ___ 4 NW Exterior Conc. Blk - Int Ins LIVING/DINING 4.1 27.0 0 8.0 0 216.0 0.149 0 0 0.40 0 % ___ 5 SE Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.40 0 % ___ 6 SW Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 18.0 0 8.0 0 144.0 0.149 0 0 0.40 0 % ___ 7 SW Exterior Conc. Blk - Int Ins BATH 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.40 0 % ___ 8 NE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.40 0 % ___ 9 SE Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.40 0 % ___ 10 NE Exterior Conc. Blk - Int Ins KITCHEN 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.40 0 % ___ 11 SE Exterior Conc. Blk - Int Ins HALL 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.40 0 % DOORS (Total Exposed Area = 40 sq.ft.) Width Height #Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 NE Insulated LIVING/DINING None 0.28 6.00 0 6.00 8 40.0ft² WINDOWS (Total Exposed Area = 102 sq.ft.) Wall -----Overhang----- #Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening ___ 1 NW 4 Metal Single (Clear)Yes 0.65 0.51 N N 48.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 2 SW 6 Metal Single (Clear)Yes 0.65 0.51 N N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 3 SW 7 Metal Single (Clear)Yes 0.65 0.51 N N 6.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 4 NE 8 Metal Single (Clear)Yes 0.65 0.51 N N 12.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 5 NE 10 Metal Single (Clear)Yes 0.65 0.51 N N 24.0ft²2.0 ft 0 in 1.0 ft 4 in None None 2/7/2022 2:57:18 PM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION #Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) ___ 1 Wholehouse Proposed ACH(50)0.00025 792 43.45 81.58 0.0902 5.0 All MASS #Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 LIVING/DINING ___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 1 ___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH ___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2 ___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN ___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL ___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 A/C HEATING SYSTEM #System Type/Fl. Addition Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Strip Heat/Existing/co None COP: 1.00 17.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM #System Type/Fl. Addition Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit/Existing/co Split/Single SEER:16.0 23.6 708 0.70 sys#1 1 HOT WATER SYSTEM #System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length ___ 1 Electric None A/C 0.95 (0.93)50.00 gal 61 gal 120 deg Standard None 79 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC # #Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 Attic 6.0 125 ft²Attic 6.0 65 ft²Proposed Qn A/C ------0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec 2/7/2022 2:57:18 PM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES(Continued) Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ___ Cooling (WD)AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 ___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 ___ Heating (WD)AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 ___ Heating (WEH)AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name:1764 W MIDWAY ROAD Builder Name: Street:1764 W. MIDWAY ROAD Permit Office: City, State, Zip:FT. PIERCE, FL, Permit Number: Owner:Jurisdiction: Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed.a material having a thermal resistance of R-3 per Knee walls shall be sealed.inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation.maintain permanent contact with the underside of above-garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs.be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/7/2022 2:57:18 PM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1764 W. MIDWAY ROAD,FT. PIERCE,FL, 1. New construction or existing Addition 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. Is this a worst case?No 6. Conditioned floor area above grade (ft²)1188 Conditioned floor area below grade (ft²)0 7. Windows**Description Area a. U-Factor:Sgl, U=0.65 102.00 ft2 S H G C :SHGC=0.51 b. U-Factor:N/A f t2 S H G C : c. U-Factor:N/A f t2 S H G C : Area Weighted Average Overhang Depth:2.000 ft Area Weighted Average SHGC:0.510 8. Skylights Description Area U - F a c t o r : ( A V G )N/A N/A ft2 S H G C ( A V G ) :N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1188.00 f t2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(1200.0 sqft.) I n s u l a t i o n Area a. Concrete Block - Int Insul, ExteriorR=4.1 1200.00 ft2 b. N/A R = f t2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(1188.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented)R=30.0 1188.00 ft2 b. N/A R= f t2 c. N/A R= f t2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: A/C 6 125 b . c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 23.6 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Strip Heat 17.0 COP:1.00 15. Hot Water Systems - a. Electric Cap: 50 gallons EF: 0.950 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ___________________________________Date: _________________________ Address of New Home: 1764 W. MIDWAY ROAD City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/7/2022 2:57:18 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1