Loading...
HomeMy WebLinkAboutEPL Display Card:T d ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*,_= 75 The lower the EnergyPerformance Index, the more efficient the hpme, 22 AQUA RA DRIVE, JENSEN BEACH, FL, 34957- 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows— Description a. U-Factor Sgl, U=1.07 SHGC: SHGC=0.30 b. U-Factor. N/A SHGC: c. U-Factor. N/A SHGC: d. U-Factor WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. NIA c. N/A Addition Single-family 1 0(0) No 295 Area 30.00 ft2 Insulation R=0.0 R= 9. Wall Types a. Concrete Block- Int Insul, Exterior b. N/A c. NIA d. N/A 10. Ceiling Types a. Under Attic (Vented) 4.,N/A c. N/A 11. Ducts ft2 12. Cooling systems ft2 a. Central Unit ft2 2.000 fi. 0.300 Area 295.00 ft ft2 ft2 13. Heating systems a. Electric Strip Heat Insulation R=4.1 R= R= R= Insulation R=30.0 R= R= Area 612.00 ft2 ft2 ftZ ft2 Area 295.00 ft2 ft2 ftZ R ft2 kBtu/hr Efficiency 9.0 SEER:13.00 kBtu/hr Efficiency 6.0 COP:1 UO 14. Hot water systems -Replacement equipment a. Electric Cap: 50 gallons ER 0.97 b. Conservation features None 15. CrQdits I certify that this home has complied with the Florida Energy. Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. --Builder Signature: / Date: ig % Z/if /`f Address of New Home: �q �tJ� jz,g pCity/FL Zipr 3q q, % Pstat "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Building Type: Owner. # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: NeW/F)dsting: Comment: MOON User 1 Single-family Addition Bedrooms: 0 Conditioned Area: 295 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # BlocidSubDivision: PlatBook Street: 22 AQUA RA DRIVE County. ST. LUCIE City, State, Zip: JENSEN BEACH, FL, 34957- CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2-5 % Int Design Temp Heating Design Daily Temp Winter Summer gegree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume Blockl 295 2655 SPACES ' Number Name Area Volume Kitchen Occupants Bedroomq InfilID Finished Cooled Heated 1 ZONE 1 295 2655 No 1 1 Yes Yes Yes ` FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatip ZONE 1 68 ft 0 295 ftz — 0 0 1 . ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emift Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Metal 320 T 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented $00 295 fie N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) ZONE 1 30 295 T 0.11 Wood 11131201411:55 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 _ WALLS Adjacent Spacenmf Tn Wall Type Cavity Width Height Sheathing_ Framing -Solar Below 0 _ 1 N _ 2 S _ 3 E 4 W Exterior Concrete Block - Int Insul ZONE 1 Exterior Concrete Block - Int Insul ZONE 1 Exterior Concrete Block - Int Insul ZONE 1 Exterior Concrete Block- Int Insul ZONE 1 4.1 15 9 135 ftz 4.1 4.1 15 9 135 T 4.1 4.1 19 9 171 T 4.1 4.1 19 9 171 T 4.1 0 0.76 0 0.75 0 0.75 0 0.75 0 0 0 0 DOORS # Omt DoorType Space Storms U Value I Ft In In eight Ft h Area 1 2 N insulated ZONE 1 E Insulated ZONE 1 Metal 0.460000 3 Metal 0.460000 3 8 8 24 ft= 48 fB WINDOWS Orientation shown is the'entered, Proposed orientation. # Wa» Omt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 2 S 2 Metal Low E Single Yes E 3 Metal Low-E Single Yes 1.07 0.3 6 R2 2 ft 0 in 0 ft 0 in 1.07 0.3 24 f ! 2 ft 0 In 0 ft 0 ip Drapes/brinds Drapes/blinds None None INFILTRATION # Scope Method SLA ¢FM 50 ELA EgLA ACH ACH 50 1 ,-Wholehouse Best Guess 0.000500 386.89 21.240 39.944 0.3650 8.7433 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts, 1 Electric Strip Heat None COP:1 6 k9tu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER 13 9 kBtulhr: 270 ofm 0.75 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation, 1 Electric None ZONE 1 0.97 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None IF 1 /131201411:55 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 • TEMPERATURES PMgramable Thermostat: Y Ceiling_ Fans: Cooling [] Jan HeatingJan Feb Feb Mar Mar [ j Apr [ j Apr ] Ma ]May [X] Jun i) Jun [Xj Jul [ ] JuI [X] Au [ ]Aug n Se SeP Oct Oct W Nov Nov Dec Dec Venting [[ ]] Jan Feb. Mar [X1 Apr [ l May [ ] Jun [ 1 Jul. [ ] Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooting_(WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 IM31201411:55 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method - ADDRESS: 22 AQUA RA DRIVE PERMIT #: JENSEN BEACH, FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for fgll details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402A To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30r cfmisgft Testing or visual -inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is requited. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 Ali ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R 2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403-9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be derided into two or more stages. Ceilings/knee walls 4052.1 7R-19 space permitting. 1/13/201411.55 AM EnergyGauge® USA - RaRes2010 Section 405.4.1 Compliant Sottware Page 5 of 5