Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLbRIbA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ,Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MOON Builder Name: Street 22 AQUA RA DRIVE Permit Office: City, State, Zip: JENSEN BEACH, FL, M57- Permit Number. Owner. Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or e)dsting Addition 9. Wall Types (612.0 sgfL) Insulation Area a. Concrete Block- Int,nsul, Exterior R=4.1 612.00 ft2 . 2. Single family or multiple fart{ Single-family 9 Y P Y g y b. N/A R=, ft2 3. Number of units, if multiple family 1 c. N/A R= fH 4. Number of BAdrooms(Bedrms In Addition) '0(0) d. NIA 10. Ceiling Types (295.0 sgfL) R= fe Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 295.00 fF 6. Conditioned floor area above grade 295 b. WA R= fF c. NIA R= ft2 Conditioned floor area below grade (ft2) 0 11 Ducts R ft2 7. WRndows(30.0 sgfL) Description Area a. U-Factor. Sgl, U=1.07 30.00 ft2 :SHGC; SHG(--UO ftZ 12. Cooling systems kBtu/hr Efficiency b. U-Factor. NIA a. Central Unit 9.0 SEER:13.00 SHGC: "'all'Factor. NIA fIZ ;SHGC: 13. Heating systems . kBtu/hr Efficiency d. 'U-Factor. N/A ft2 a. Electric Strip Heat 6.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.o q ft.. 14. Hot water systems - Replacement equipment Area Weighted Average SHGC: 0.300 a. Electric Cap: 50 gallons 8. FloorTypes (295.0 sgfL) Insulation Area ' EF. 0.970 a. Slab -On -Grade Edge Insulation R2=0.0 295.00 f12 b. Conservation features b. WA R= ft2 None a WA R= ft2 15. Credits Pstat Total Proposed Modified Loads: 6.78 PASS GlasslFloorArea: 0.102 Total Standard Reference Loads: 9.07 I hereby certify that the plans and specifications covered Review of the.plans and'S s7147, this calculation are in compliance with the Florida En specifications covered by this Code. sl;D1- o��-(� -OL( calculation indicates complianceii�i �Ct��Cl S 1 'eQ(�Ce with the Florida Energy Code. Before construction is. completed PREP �EY' DATE: 2C� (tiA CQ� 4 this building will be inspected for i- compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. �J OWNERIAGE T:, i`� BUILDING OFFIQIAL'. DATE. 1LL� �'� v DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Chedklist - Heat sys #1 may be undersized. Size of 6.0 was increased to 6.5 for simulation. Please review the Manual J8 report, 1/13/201411:55 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant So�"re Page 1 of 5