HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLbRIbA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
,Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MOON
Builder Name:
Street 22 AQUA RA DRIVE
Permit Office:
City, State, Zip: JENSEN BEACH, FL, M57-
Permit Number.
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or e)dsting Addition
9. Wall Types (612.0 sgfL)
Insulation Area
a. Concrete Block- Int,nsul, Exterior
R=4.1 612.00 ft2 .
2. Single family or multiple fart{ Single-family
9 Y P Y g y
b. N/A
R=, ft2
3. Number of units, if multiple family 1
c. N/A
R= fH
4. Number of BAdrooms(Bedrms In Addition) '0(0)
d. NIA
10. Ceiling Types (295.0 sgfL)
R= fe
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 295.00 fF
6. Conditioned floor area above grade 295
b. WA
R= fF
c. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
11 Ducts
R ft2
7. WRndows(30.0 sgfL) Description Area
a. U-Factor. Sgl, U=1.07 30.00 ft2
:SHGC; SHG(--UO
ftZ
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor. NIA
a. Central Unit
9.0 SEER:13.00
SHGC:
"'all'Factor. NIA fIZ
;SHGC:
13. Heating systems .
kBtu/hr Efficiency
d. 'U-Factor. N/A ft2
a. Electric Strip Heat
6.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.o q ft..
14. Hot water systems - Replacement equipment
Area Weighted Average SHGC: 0.300
a. Electric
Cap: 50 gallons
8. FloorTypes (295.0 sgfL) Insulation Area
' EF. 0.970
a. Slab -On -Grade Edge Insulation R2=0.0 295.00 f12
b. Conservation features
b. WA R= ft2
None
a WA R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 6.78
PASS
GlasslFloorArea: 0.102
Total Standard Reference Loads: 9.07
I hereby certify that the plans and specifications covered
Review of the.plans and'S
s7147,
this calculation are in compliance with the Florida En
specifications covered by this
Code. sl;D1- o��-(� -OL(
calculation indicates complianceii�i
�Ct��Cl S 1 'eQ(�Ce
with the Florida Energy Code.
Before construction is. completed
PREP �EY'
DATE: 2C� (tiA CQ� 4
this building will be inspected for
i-
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
�J
OWNERIAGE T:, i`�
BUILDING OFFIQIAL'.
DATE. 1LL� �'� v
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Chedklist
- Heat sys #1 may be undersized. Size of 6.0 was increased to 6.5 for simulation. Please review the Manual J8 report,
1/13/201411:55 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant So�"re Page 1 of 5