HomeMy WebLinkAboutFL_1 Snap 24 Ga_1225 1/11/2021 Florida Building Code Online
Business & iYl ,I tIF, _
ProfessionalRegulation
r
BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search
bpr
Product Approval` USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL17678-R7
SFCRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Drexel Metals,Inc.
Address/Phone/Email 204 Railroad Drive
Ivyland, PA 18974
(502) 303-1511
jshumate@drexmet.com
Authorized Signature Jason Shumate
jshumate@drexmet.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity Architectural Testing,Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2025
Validated By Locke Bowden P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL17678 R7 COI DRX15001.7 2020 FBC Eval Metal Roofing NonHVHZ
final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM B 117 2016
ASTM G 155 2013
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 580 2006
UL1897 2012
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFRw8MKNWOmtb4lHCXvgN6%2fDfEFsngfOOgBQ%3d%3d 1/2
1/11/2021 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/09/2020
Date Validated 08/10/2020
Date Pending FBC Approval 08/20/2020
Date Approved 10/13/2020
Summary of Products
FL# Model,Number or Name Description
17678.1 Drexel Metal Roofing Systems DMC 100NS, DMC 150SL, DMC 150SS, DMC 175S, DMC 200S,
DMC 450, DMC 5V&DMC Corrugated
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17678 R7 II DRX15001.7 2020 FBC Eval Metal Roofing
Approved for use outside HVHZ:Yes NonHVHZ final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-180 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use Evaluation Reports
FL17678 R7 AE DRX15001.7 2020 FBC Eval Metal Roofing.
NonHVHZ final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® 0J ® eCheck MM
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFRw8MKNWOmtb4lHCXvgN6%2fDfEFsngfoOgBQ%3d%3d 2/2
CREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020)
Manufacturer: DREXEL METALS, INC. Issued August 9, 2020
1234 Gardiner Lane
Louisville, KY 40213
(502)716-7143
www.drexmet.com
Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM)
Quality Assurance: Architectural Testing, Inc., an Intertek Company(QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006
UL1897 2012
Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006
UL1897 2012
Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006
UL1897 2012
Architectural Testing, Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006
Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006
UL1897 2012
Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006
UL1897 2012
Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016
TAS 110 2000
PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2013
TAS 110 2000
PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006
UL1897 2012
DRX15001.7 FL17678-R7 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, L.LC
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006
UL1897 2012
PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006
UL1897 2012
PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006
UL1897 2012
PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006
UL1897 2012
PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006
UL1897 2012
PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006
UL1897 2012
PRODUCT DESCRIPTION
DMC 100NS Profile: 1 in. snap lock seam; Max.16 in. coverage
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural, snap lock standing seam roof panel with integral perorated nail
strip
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or
ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
16"
1" -"D.C.
DMC 150SL Profile: 1.5 in. snap lock seam; Max. 16 in. coverage
......................................................................:.................................................................................................................................................................................................................................................................................................................................................................
.
Description: Non-structural, snap lock standing seam roof panel
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or
ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
12'
DRX15001.7 FL17678-R7 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL,C
DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in. coverage
.........................................................................................................................................................................................................................................................
Description: Non-structural, mechanical lock standing seam roof panel
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min.24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min.
50 ksi; Shall conform with FBC Section 1507.4.3
...................................................................... ..............................................................................................................................................................................................
2 3„
12 16
........................................................................ .................... ....................
Material: Min. 0.027 in.Zinc; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3
12
1`7" -�
DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage
...................................................................................................................
Description: Non-structural, snap lock standing seam roof panel
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 24 ksi; Shall
conform with FBC Section 1507.4.3
..................................................................................................................................................................................................................................................................................................................................................................
Min. 0.040-inch Fluropon®coated ASTM B209 aluminum (Fy= min.20 ksi); Shall
conform with FBC Section 1507.4.3
..........................................................................................................................
Min.24 ga. Fluropon®coated ASTM A792 AZ50, or
ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
1 4"
18"
DMC 200S Profile: 2 in. mechanical seam; Max. 16 in.coverage
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural, mechanical lock standing seam roof panel
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.0.040 in. Fluropon®coated ASTM B209 aluminum; Fy= min. 20 ksi; Shall
conform with FBC Section 1507.4.3
: ..................................................................................................................................................................................................................................................................................................................................................................
Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3
...................................................................................................................................................................................................................................................................................................................................................................
„ T 7 7
2" 2"
ts„
1
DRX15001.7 FL17678-R7 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL,C
DMC 450 Profile: 1.5 in. snap lock seam; Max. 16 in. coverage
............................................................................................................ .......... ................................................
Description: Non-structural, snap lock standing seam roof panel with concealed clip
....................................................................... .........................................................................................................................................................................
Material: Min.24 ga.ASTM A792 or ASTM A653; Fy= min.50 ksi; Shall conform with FBC
Section 1507.4.3
......................................................................................................................................................................................................................................................
Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 24 ksi; Shall
conform with FBC Section 1507.4.3
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
12
a
16"
DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in.coverage
.. ......................................................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural, through fastened roof panel
........... ......
Material: Min.26 ga. Fluropon®coated ASTM A792 or ASTM A653 G90 ; Fy=min.50 ksi;
Shall conform with FBC Section 1507.4.3
................................................................................................................................................................
Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 23 ksi; Shall
conform with FBC Section 1507.4.3
:........................................................................................................................................................................................................................................................................................................................................................................................................................................
21"up to 24"Coverage
8
DMC Profile: 1/2 in.corrugation; 21 in.coverage
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Corrugated Description: Non-structural,through fastened roof panel
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.26 ga. Fluropon®coated ASTM A792 or ASTM A653 G90 ; Fy=min.40 ksi;
Shall conform with FBC Section 1507.4.3
Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 19 ksi; Shall
conform with FBC Section 1507.4.3
......................................................................................................................................................................................................................................................................................................................................................................................................................................
28„
1"
2
1 '16 L
DRX15001.7 FL17678-R7 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer.
,•����P�Y...... pR%, 2020.08.09
�`�,VP•'• *\G•E•N Sc� ' S lo.
15:00:49
o 74021 N
-04'00'
' STATE OF
'�T• 'c P;•'•��� Zachary R. Priest, P.E.
Florida Registration 021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A— Installation (12 pages)
2) APPENDIX B—Approved Roof Systems(8 pages)
3) APPENDIX C—Design Wind Loads (4 pages)
DRX15001.7 FL17678-R7 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#10-14 HWH wood screw
with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion
#10-15 HWH wood resistant in accordance with FBC section 1507.4.4.
Fasteners screws with dual threads
and sealing washer
#10-13 PH wood screw
#10-16 DP3 PH self-
drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
#14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4.
drilling screw
311
Bearing Plates 18 ga.Bearing Plate ® 7
24 ga. in-seam clip yy
DMC 150SL Clip
Q �
Clips 24 ga.SS in-seam clip ..
/ 7n
/ 16
24 ga. DMC 150SS Clip 3., T �g
8
o T
0 1
4 _/ 2„
4
DRX15001.7 FL17678-R7 Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Component Product Installation Detail
24 ga. in-seam clip
7n
7
24 ga. DMC 15OSS Fixed „ T �8"
Clip 8
0
o
16
26 ga. in-seam clip
7
26 ga. DMC 150SS Fixed ,_,,� ,
Clip
0
0
22 ga.SS in-seam clip
7 7 18
/ 16
L L
Clips(Cont'd) 22 ga. DMC 150SS Clip 1, T o
a
d
' 01
3 Y
4
22 ga. in-seam clip
18 1a°
22 ga. DMC 150SS Fixed L
Clip 8„ T
Q C
a �n
3
4
22 ga. base;24 ga.butterfly in-seam clip
DMC 150SS Butterfly
Clip >
4.
DRX15001.7 FL17678-R7 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Component Product Installation Detail
22 ga.base;24 ga.butterfly in-seam clip
DMC 15OSS Continuous
Butterfly Clip
,
26 ga.in-seam clip
DMC 150SS Utility o
Floating Clip
0 3„
Clips(Cont'd)
18 ga. in-seam clip
DMC 175S UL Clip
p
22 ga.SS in-seam clip
a
1
o
DMC 200S Clip �
0
o
0
�/ 3"
DRX15001.7 FL17678-R7 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Component Product Installation Detail
18 ga. base;22 ga.butterfly in-seam clip;4.5 in.length
DMC 200S Butterfly Clip
18 ga. base;22 ga.butterfly in-seam clip; 120 in.length;top slider 12 in.o.c.
DMC 200S Continuous
Butterfly Clip {
Clips(Cont'd)
cY
,i
24 ga. in-seam clip
DMC 450 Clip
o
24 ga.SS in-seam clip
DMC 450SS Clip
o
Bostik 70-05A
Sealants Shall be applied in continuous beads along the seam
Bostik Chem-Calk 915
Fastening Details
Nomenclature Attachment
DMC 10O S PANEL
##10 - 13 PH1
DMC 100NS Standard
DRX15001.7 FL17678-R7 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 10ONS PANEL
BDBTII 70-05A ( - 3116" BEADS)
f #10 - 13 PHW
DMC 100NS Enhanced
DMC 150SL PANEL
DMC 150SL CLIP
#10-13 PHW(2 Per Clip)
UNDERLAYMENT
DMC 150SL Standard
DMC 150SS PANEL
DMC 15OSS CONTINUOUS BUTTERFLY CLIP
(2)#10-13 PHW
UNDERLAYMENT
DMC 150SS Continuous SUBSTRATE
Butterfly
DMC 150SS PANEL
DMC 150SS BUTTERFLY CLIP
(2)#10-13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 150SS Butterfly
DRX15001.7 FL17678-R7 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS PANEL
DMC 15OSS BUTTERFLY CLIP
(2)#14- 13 PHDD
UNDERLAYMENT
W- 18GA BEARING PLATE
ISO INSULATION
METAL DECK
DMC 150SS#14 Butterfly
DMC 15OSS PANEL
24 GA DMC 15OSS FIXED CLIP
(2)#10-13 PHW
UNDERLAYMENT
DMC 150SS Fixed-90 SUBSTRATE
it
NIN'BEAB BOSTIK CHEM.CALK 91 S
APPLIED TO BOTH SIDES OF CLIP
DMC 15OSS PANEL
24OA DMC h50SS FIXED CLIP
114"BEAD BOSTIK CHEM-CALK 9'
APPLIED TO BOTH SIDE OF CLIP
DMC 150SS#14 Fixed-
90
2 #14-13 DP1,PH Screws per clip; Clip installed over 18 ga.bearing plate
DMC 15OSS PANEL,
24 GA DMC 15OSS CLIP
(2)#10- 13 PHW
UNDERLAYMENT
DMC 150SS Standard(Al) SUBSTRATE
DRX15001.7 FL17678-R7 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
1/4"BEAD BOSTIK 70-05A—
DMC 150SS PANEL
22 GA DMC 150SS FIXED CLIP
DMC 150SS Fixed N#10-13 PHW
Enhanced-90 UNDERLAYMENT
SUBSTRATE
l
DMC 150SS PANEL
22 GA DMC 150SS FIXED CLIP
(2)#10- 13 PHW
UNDERLAYMENT
DMC 150SS Fixed SUBSTRATE
Enhanced-180
1/4"BEAD BOSTIK 70-05A
DMC 150SS PANEL
22 GA DMC 150SS CLIP
(2)#10-13 PHW
DMC 150SS Enhanced(Al) UNDERLAYMENT
SUBSTRATE
DRX15001.7 FL17678-R7 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS PANEL
DMC 15OSS CLIP
(2) #10-13 PH Screws
UNDERLAYMENT 1
DMC 150SS Zinc SUBSTRATE
IV y
DMC 175S Panel
DMC 175S UL Cip
#10-111 PH Screw
(2)per cop
DMC 175S#10 Standard
DMC 175S Panel
DMC 1755 UL Clip
ffl-13 PH Screw
f2l per clip
114"BEAD BOSTIK CHEM-CALK
915 MALE LEG AND BOTH SIDES
OF CLIP
V9"BEAD B08Tk CHEM-CALK '-
DMC 175S#10 Enhanced 915 ON FEMALE LEG
DRX15001.7 FL17678-R7 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 175S PANEL
DMC 175S LIL CLIP
014-13 DP1 PHDD(2 Par Clip)
3X3-13GA BEARING PLATE
METAL DECK
ISO INSULATION
]�
DMC 175S#14 Standard
DMC 200S PANEL
DMC 200S BUTTERFLY CLIP
(2)#10-13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 200S Butterfly
DMC 200S PANEL
DMC 200S BUTTERFLY CLIP
#10 - 16 DP3 PHD
UNDERLAYMENT
METAL DECK
DMC 200S Butterfly(Steel)
Use 18 ga.bearing plate over polyisocyanurate insulation
DRX15001.7 FL17678-R7 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 200S PANEL
DMC 200S CONTINOUS
BUTTERLY CLIP
#10 - 16 DP3 PHD
UNDERLAYMENT
METAL DECK
DMC 200S Continuous
Butterfly(Steel)
Use 18 ga.bearing plate over pol isoc anurate insulation
DMC 200S PANEL
DMC 200S CLIP
(2)#10-13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 200S Fixed
1/4"BEAD BOSTIK 70-05A
DMC 200S PANEL
QMC 200S CLIP
(2)#10-13 PHW
DMC 200S Fixed UNDERLAYMENT
Enhanced
SUBSTRATE
DRX15001.7 FL17678-R7 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 450 PANEL
DMC 450 CLIP
#10- 13 PHW(2 Per Clip)
DMC 450 Standard
I&==27 ---
DMC 450 PANEL
DMC 450 SS CLIP
#10- 13 PHW(2 Per Clip)
DMC 450SS Standard
p9-15 HWH WOOD SCREW WITH
SEALING WASHER
DMC 5V Standard
DRX15001.7 FL17678-R7 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Fastening Details
Nomenclature Attachment
#10- 14 DREXMET WOODSCREW
DMC 5V PANEL
METSHIELD HT UNDERLAYMENT
DMC 5V#10 Standard PLYWOOD
DMC 5V PANEL
#10-14 DREXMET WOODSCREW
UNDERLAYMENT
7I16"OSB MIN.
DMC 5V Pan Fastening
ONLY REQUIRED AT
PANEL ENDS \
1'-9" COVERAGE
#10-15 HWH WOO DSC R EW(DUAL THREAD)
12"o.c. to 36"o.c. MAX. ROW SPACING
DMC Corrugated UNDERLAYMENT
15/32" MIN. PLYWOOD
ZiL
DRX15001.7 FL17678-R7 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy= min.40 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0& FBC.
6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
100NS-W# DMC 100NS over Wood Deck(New or Existing)
150SL-W# DMC 150SL over Wood Deck(New or Existing)
150SS-S# DMC 150SS over Steel Deck(New or Existing)
150SS-W# DMC 150SS over Wood Deck New or Existing
175S-S# DMC 175S over Steel Deck(New or Existing)
175S-W# DMC 175S over Wood Deck(new or Existing)
200S-S# DMC 200S over Steel Deck(New or Existing)
200S-W# DMC 200S over Wood Deck(New or Existing)
450-W# DMC 450 over Wood Deck(New or Existing)
5V-W# DMC 5V over Wood Deck(New or Existing)
COR-W# DMC Corrugated over Wood Deck New or Existing)
Approved Systems for DMC 100NS over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
10ONS-W1 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Standard attachment 97 5
CDX plywood Versashield Solo Max. 16-inch wide with fastener spaced 10.5 in.o.c.
100NS-W2 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Standard attachment -120
CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c.
100NS-W3 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Enhanced attachment -135
CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c.
DRX15001.7 FL17678-R7 Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SL over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL 24 ga. DMC 150SL DMC 150SL Standard attachment
150SL-W1 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -52.5
Approved Systems for DMC 150SS over Steel Deck(New or Existing)
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-Sl Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 36 in.o.c. -41.7
Grade 80 Steel insulation board
Min.22 ga. Min. 1 in.Approved Approved ASTM D 24 ga. DMC 150SS DMC 150SS#14 Fixed-90 attachment
150SS-S2 Type B, As required polyisocyan u rate 1970 underlayment Max. 16-inch wide with clips spaced 16 in.o.c. -71
Grade 80 Steel insulation board
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S3 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 24 in.o.c. -92.4
Grade 80 Steel insulation board
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S4 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 18 in.o.c. -117.8
Grade 80 Steel insulation board
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S5 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 12 in.o.c. -143.1
Grade 80 Steel insulation board
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S6 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 6 in.o.c. -168.5
Grade 80 Steel insulation board
DRX15001.7 FL17678-R7 Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP(psf)
No.
0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment
150SS-Wl Min. 15/32 OPTIONAL Approved ASTM D 150SS with DMC 150SS Utility Floating Clips -78.5
CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide spaced 18 in.o.c.
180'seam
0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment
150SS-W2 Min. 15/32 OPTIONAL Approved ASTM D 150SS with DMC 150SS Utility Floating Clips -86
CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide spaced 6 in.o.c.
180'seam
0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment
150SS-W3 Min. 15/32 OPTIONAL Approved ASTM D 150SS with 26 ga. DMC 150SS Fixed Clips spaced -86
CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide 18 in.o.c.
180'seam
Min. 15/32 OPTIONAL 0.032"Al DMC 150SS DMC 150SS Standard(Al)attachment
150SS-W4 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -90
180'seam
150SS-W5 Min. 15/32 OPTIONAL As required per FBC Max. 1 24 ga. DMC 150SS6-inch wide DMC 150SS Fixed-90 attachment
CDX plywood Versashield Solo 1 seam with clips spaced 16 in.o.c. 90
DMC 150SS
Min. 15/32 OPTIONAL 24 ga. DMC 150SS Butterfly attachment
150SS-W6 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -99.25
180'seam
0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment
150SS-W7 Min. 15/32 OPTIONAL Approved ASTM D 150SS with 26 ga. DMC 150SS Fixed Clips spaced -108.5
CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide 9 in.o.c.
180'seam
Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Continuous Butterfly
150SS-W8 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment with fasteners spaced 12 in.o.c. -114.25
180'seam
Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced-90
150SS-W9 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -150
Min.90'seam with clips spaced 12 in.o.c.
Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced- 180
150SS-W10 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -165
Min. 180'seam with clips spaced 8 in.o.c.
DRX15001.7 FL17678-R7 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP(psf)
No.
032"AlDMC 150SS
Min. 15/32 OPTIONAL 0. DMC 150SS Enhanced(Al)attachment
150SS-W11 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -180
180'seam
Approved Systems for DMC 175S over Steel Deck(New or Existing)
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 1 in.Approved
Min.22 ga. 24 ga. DMC 175S DMC 175S#14 Standard attachment
175S-S1 As required polyisocyanu rate As required per FBC -60
Type B Steel insulation board Max. 18 inch wide with clips spaced 36 in.o.c.
Min. 1 in.Approved
Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment
175S-S2 As required polyisocyanu rate As required per FBC -88
Type B Steel insulation board Max. 17.5 inch wide with clips spaced 18 in.o.c.
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 175S DMC 175S#14 Standard attachment
175S-S3 As required polyisocyanu rate As required per FBC -105
Type B Steel insulation board Max. 18 inch wide with clips spaced 6 in.o.c.
Min. 1 in.Approved
Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment
175S-S4 As required polyisocyanu rate As required per FBC -129.25
Type B Steel insulation board Max. 17.5 inch wide with clips spaced 12 in.o.c.
Approved Systems for DMC 175S over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-W1 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 24 in.o.c. -52.5
Solo
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-W2 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 18 in.o.c. -59.4
Solo
DRX15001.7 FL17678-R7 Page 4 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 175S over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-W3 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 12 in.o.c. -66.4
Solo
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-W4 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 8 in.o.c. -71
Solo
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Enhanced attachment
175S-W5 CDX plywood Versashield Approved ASTM D 1970 underlayment Max. 18-inch wide with clips spaced 12 in.o.c. -71
Solo
ASTM D 226,Type II roofing felt attached per
175S-W6 Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -74.75
CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 24 in.o.c.
Underlayment self-adhered to felt
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-W7 CDX plywood Versashield As required per FBC Max. 14-inch wide with clips spaced 12 in.o.c. -82.5
Solo
Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment
175S-W8 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 16 in.o.c. -84.25
Solo
Min. 19/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment
175S-W9 CDX plywood Versashield As required per FBC Max. 16-inch wide with clips spaced 25 in.o.c. -97.5
Solo
Min. 15/32 OPTIONAL 0.040"Al DMC 175S DMC 175S#10 Standard attachment
175S-W10 CDX plywood Versashield As required per FBC Max. 17.5-inch wide with clips spaced 18 in.o.c. -106.75
Solo
Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment
175S-W11 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 8 in.o.c. -121.75
Solo
ASTM D 226,Type II roofing felt attached per
175S-W12 Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -131
CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 6 in.o.c.
Underlayment self-adhered to felt
Min. 19/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment
175S-W13 CDX plywood Versashield As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -135
Solo
DRX15001.7 FL17678-R7 Page 5 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 200S over Steel Deck(New or Existing)
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 1 in.Approved 24 ga. DMC 200S
Min.22 ga. DMC 200S Butterfly(Steel)attachment
20OS-S1 As required polyisocyanu rate As required per FBC Max. 16-inch wide -88
Type B Steel insulation board 180°seam with clips spaced 24 in.o.c.
Min.22 ga. 24 ga. DMC 200S DMC 200S Butterfly(Steel)attachment
200S-S2 Type B Steel As required None As required per FBC Max. 16-inch wide with clips spaced 24 in.o.c. -91.75
180°seam
Min.22 ga. Min. 1 in.Approved 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel)
200S-S3 As required polyisocyanu rate As required per FBC Max. 16-inch wide -121.75
Type B Steel insulation board 180°seam attachment with clips spaced 12 in.o.c.
Min.22 ga. 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel)
200S-S4 Type B Steel As required None As required per FBC Max. 16-inch wide attachment with clips spaced 12 in.o.c. -151.75
180°seam
Approved Systems for DMC 200S over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
20OS-W1 Min.plywood
24 ga. DMC 200S OPTIONAL As required per FBC Max. 16-inch wide DMC 200S Butterfly attachment -67.5
CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c.
200S-W2 Min.plywood
0.040"Al DMC 200S OPTIONAL As required per FBC Max. 16-inch wide DMC 200S Butterfly attachment 75
CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c.
040"AlDMC 200S
Min. 19/32 OPTIONAL 0. DMC 200S Fixed attachment
200S-W3 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -105
180°seam
200S-W4 Min. 19/32 OPTIONAL As required per FBC Max. 16-inch wide 0.040"Al DMC 200S DMC 200S Fixed Enhanced attachment -180
CDX plywood Versashield Solo 180°seam with clips spaced 8 in.o.c.
DRX15001.7 FL17678-R7 Page 6 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 450 over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
450-W1 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment -30
CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 24 in.o.c.
Min. 15/32 OPTIONAL 0.032"Al DMC 450 DMC 450SS Standard attachment
450-W2 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. 45
450-W3 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment -67.5
CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 15.5 in.o.c.
450-W4 Min. 15/32 OPTIONAL As required per FBC 0.032"Al DMC 450 DMC 450SS Standard attachment 75
CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c.
450-W5 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment 82 5
CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c.
Approved Systems for DMC 5V over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
ASTM D 226,Type II roofing felt attached per 0.032"Al DMC 5V
OPTIONAL DMC 5V#10 Standard attachment
Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to
5V-W1 CDX plywood Approved fire barrier or insulation followed by Metshield High-Temp Max.24-inch with#10 w4 HWH wood screws with -56
Underlayment self-adhered to felt coverage sealing washers spaced 18 in.o.c.
26 ga. DMC 5V
OPTIONAL DMC 5V Standard attachment
Min. 15/32 Min.21-inch to
5V-W2 CDX plywood Approved fire barrier As required per FBC Max.24-inch with#9-15 HWH wood screws with -60
or insulation coverage sealing washers spaced 16 in.o.c.
ASTM D 226,Type II roofing felt attached per 26 ga. DMC 5V
OPTIONAL DMC 5V#10 Standard attachment
Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to
5V-W3 CDX plywood Approved fire barrier or insulation followed by Metshield High-Temp Max.24-inch with#10 w4 HWH wood screws with 71
Underlayment self-adhered to felt coverage sealing washers spaced 24 in.o.c.
DRX15001.7 FL17678-R7 Page 7 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 5V over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
26 ga. DMC 5V
OPTIONAL DMC 5V Pan Fastening attachment
5V-W4 Min.7/16 OSB Approved fire barrier As required per FBC Min.21-inch to with#10-14 HWH wood screws with -75
plywood or insulation Max.24-inch sealing washers spaced 16 in.o.c.
coverage
26 ga. DMC 5V
OPTIONAL DMC 5V Pan Fastening attachment
5V-W5 Min.7/16 OSB Approved fire barrier As required per FBC Min.21-inch to with#10-14 HWH wood screws with -112.5
plywood or insulation Max.24-inch sealing washers spaced 8 in.o.c.
coverage
26 ga. DMC 5V
OPTIONAL DMC 5V Standard attachment
Min. 15/32 Min.21-inch to
5V-W6 CDX plywood Approved fire barrier As required per FBC Max.24-inch with#9-15 HWH wood screws with -121.75
or insulation sealing washers spaced 8 in.o.c.
coverage
ASTM D 226,Type II roofing felt attached per 26 ga. DMC 5V or
OPTIONAL 0.032"Al DMC 5V DMC 5V#10 Standard attachment
Min. 15/32 1518.2.1 with nails and tin caps per 1517.5
5V-W7 Approved fire barrier Min.21-inch to with#10-14 HWH wood screws with -206
CDX plywood or insulation followed by nt self ad High-Temp Max.24-inch sealing washers spaced 6 in.o.c.
Underlayment self-adhered to felt
coverage
Approved Systems for DMC Corrugated over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
Min. 15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment
COR-W1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60
or insulation and sealing washer spaced 36 in.o.c.
Min. 15/32 OPTIONAL 26 ga. DMC Corrugated DMC 5V Corrugated attachment
COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage With#10-15 HWH wood screws with dual threads -60
or insulation and sealing washer spaced 36 in.o.c.
Min. 15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment
COR-W3 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -135
or insulation and sealing washer spaced 12 in.o.c.
Min. 15/32 OPTIONAL 26 ga. DMC Corrugated DMC 5V Corrugated attachment
COR-W4 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -150
or insulation and sealing washer spaced 12 in.o.c.
DRX15001.7 FL17678-R7 Page 8 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B, C, and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd=0.85
8. Vot is shown in the tables below. Design wind loads are calculated using Vasd=V,,itA.6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e,Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10% of the least horizontal dimension or(0.4 x Mean Roof Height),whichever
is smaller, but not less than either 4%of the least horizontal dimension or 3ft
Gable Hip
a X _
3 2 3 3 2 3 a \ 3 2 3 a
2 1 2 2 1 2 2 1 2 2 1 2
3 2 3 3 2 3 a 3 2 3 a
a Iola la al al-
DRX15001.7 FL17678-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure B(Roof slope between 2:12 and 12:12
Mean Basic Wind Speed mph
Building Type Zone Roof 120 130 140 150 160 170 180 190 200
Height(ft)
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
1 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 1 -61.9 -69.9 -78.4 -87.3 -96.8
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
Enclosed/ 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
Partially Open 2 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
1 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
Partially 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
Enclosed 2 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 1 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
3 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 -59.3 -69.6 1 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 1 -77.8 -90.3 1 -103.6 1 -117.9 1 -133.1 -149.2 1 -166.3 1 -184.2
DRX15001.7 FL17678-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure C(Roof slope between 2:12 and 12:12
Mean Basic Wind Speed(mph)
Building Type Zone Roof 120 130 140 150 160 170 180 190 200
Height(ft)
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
1 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
Enclosed/ 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
Partially Open 2 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 1 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 1 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
3 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
1 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
Partially 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
Enclosed 2 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
3 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2
60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9
DRX15001.7 FL17678-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure D(Roof slope between 2:12 and 12:12
Mean Basic Wind Speed mph
Building Type Zone Roof 120 130 140 150 160 170 180 190 200
Height(ft)
20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
1 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1
40 50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
Enclosed/ 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
Partially Open 2 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
3 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
1 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
Partially 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
Enclosed 2 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
3 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9
DRX15001.7 FL17678-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.