Loading...
HomeMy WebLinkAboutFL_1 Snap 24 Ga_1225 1/11/2021 Florida Building Code Online Business & iYl ,I tIF, _ ProfessionalRegulation r BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr Product Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL17678-R7 SFCRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Drexel Metals,Inc. Address/Phone/Email 204 Railroad Drive Ivyland, PA 18974 (502) 303-1511 jshumate@drexmet.com Authorized Signature Jason Shumate jshumate@drexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Architectural Testing,Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2025 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL17678 R7 COI DRX15001.7 2020 FBC Eval Metal Roofing NonHVHZ final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM B 117 2016 ASTM G 155 2013 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 580 2006 UL1897 2012 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFRw8MKNWOmtb4lHCXvgN6%2fDfEFsngfOOgBQ%3d%3d 1/2 1/11/2021 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/09/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/20/2020 Date Approved 10/13/2020 Summary of Products FL# Model,Number or Name Description 17678.1 Drexel Metal Roofing Systems DMC 100NS, DMC 150SL, DMC 150SS, DMC 175S, DMC 200S, DMC 450, DMC 5V&DMC Corrugated Limits of Use Installation Instructions Approved for use in HVHZ: No FL17678 R7 II DRX15001.7 2020 FBC Eval Metal Roofing Approved for use outside HVHZ:Yes NonHVHZ final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-180 Created by Independent Third Party: Yes Other: See evaluation report for limits of use Evaluation Reports FL17678 R7 AE DRX15001.7 2020 FBC Eval Metal Roofing. NonHVHZ final.pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® 0J ® eCheck MM Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZFRw8MKNWOmtb4lHCXvgN6%2fDfEFsngfoOgBQ%3d%3d 2/2 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: DREXEL METALS, INC. Issued August 9, 2020 1234 Gardiner Lane Louisville, KY 40213 (502)716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing, Inc., an Intertek Company(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006 UL1897 2012 Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006 UL1897 2012 Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006 UL1897 2012 Architectural Testing, Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing, Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing, Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing, Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 UL1897 2012 Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006 UL1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2013 TAS 110 2000 PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL1897 2012 DRX15001.7 FL17678-R7 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, L.LC Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL1897 2012 PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006 UL1897 2012 PRODUCT DESCRIPTION DMC 100NS Profile: 1 in. snap lock seam; Max.16 in. coverage .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, snap lock standing seam roof panel with integral perorated nail strip .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 16" 1" -"D.C. DMC 150SL Profile: 1.5 in. snap lock seam; Max. 16 in. coverage ......................................................................:................................................................................................................................................................................................................................................................................................................................................................. . Description: Non-structural, snap lock standing seam roof panel .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 12' DRX15001.7 FL17678-R7 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL,C DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in. coverage ......................................................................................................................................................................................................................................................... Description: Non-structural, mechanical lock standing seam roof panel .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 ...................................................................... .............................................................................................................................................................................................. 2 3„ 12 16 ........................................................................ .................... .................... Material: Min. 0.027 in.Zinc; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 12 1`7" -� DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage ................................................................................................................... Description: Non-structural, snap lock standing seam roof panel :.....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 24 ksi; Shall conform with FBC Section 1507.4.3 .................................................................................................................................................................................................................................................................................................................................................................. Min. 0.040-inch Fluropon®coated ASTM B209 aluminum (Fy= min.20 ksi); Shall conform with FBC Section 1507.4.3 .......................................................................................................................... Min.24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 ....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 1 4" 18" DMC 200S Profile: 2 in. mechanical seam; Max. 16 in.coverage ....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Description: Non-structural, mechanical lock standing seam roof panel ....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min.0.040 in. Fluropon®coated ASTM B209 aluminum; Fy= min. 20 ksi; Shall conform with FBC Section 1507.4.3 : .................................................................................................................................................................................................................................................................................................................................................................. Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 ................................................................................................................................................................................................................................................................................................................................................................... „ T 7 7 2" 2" ts„ 1 DRX15001.7 FL17678-R7 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL,C DMC 450 Profile: 1.5 in. snap lock seam; Max. 16 in. coverage ............................................................................................................ .......... ................................................ Description: Non-structural, snap lock standing seam roof panel with concealed clip ....................................................................... ......................................................................................................................................................................... Material: Min.24 ga.ASTM A792 or ASTM A653; Fy= min.50 ksi; Shall conform with FBC Section 1507.4.3 ...................................................................................................................................................................................................................................................... Min. 0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 24 ksi; Shall conform with FBC Section 1507.4.3 .....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. 12 a 16" DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in.coverage .. ...................................................................................................................................................................................................................................................................................................................................................................................................... Description: Non-structural, through fastened roof panel ........... ...... Material: Min.26 ga. Fluropon®coated ASTM A792 or ASTM A653 G90 ; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 ................................................................................................................................................................ Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 23 ksi; Shall conform with FBC Section 1507.4.3 :........................................................................................................................................................................................................................................................................................................................................................................................................................................ 21"up to 24"Coverage 8 DMC Profile: 1/2 in.corrugation; 21 in.coverage ....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Corrugated Description: Non-structural,through fastened roof panel ....................................................................:.................................................................................................................................................................................................................................................................................................................................................................. Material: Min.26 ga. Fluropon®coated ASTM A792 or ASTM A653 G90 ; Fy=min.40 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 19 ksi; Shall conform with FBC Section 1507.4.3 ...................................................................................................................................................................................................................................................................................................................................................................................................................................... 28„ 1" 2 1 '16 L DRX15001.7 FL17678-R7 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer. ,•����P�Y...... pR%, 2020.08.09 �`�,VP•'• *\G•E•N Sc� ' S lo. 15:00:49 o 74021 N -04'00' ' STATE OF '�T• 'c P;•'•��� Zachary R. Priest, P.E. Florida Registration 021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A— Installation (12 pages) 2) APPENDIX B—Approved Roof Systems(8 pages) 3) APPENDIX C—Design Wind Loads (4 pages) DRX15001.7 FL17678-R7 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A INSTALLATION Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail #9-15 HWH wood screw with sealing washer #10-14 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion #10-15 HWH wood resistant in accordance with FBC section 1507.4.4. Fasteners screws with dual threads and sealing washer #10-13 PH wood screw #10-16 DP3 PH self- drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be #14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4. drilling screw 311 Bearing Plates 18 ga.Bearing Plate ® 7 24 ga. in-seam clip yy DMC 150SL Clip Q � Clips 24 ga.SS in-seam clip .. / 7n / 16 24 ga. DMC 150SS Clip 3., T �g 8 o T 0 1 4 _/ 2„ 4 DRX15001.7 FL17678-R7 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Component Product Installation Detail 24 ga. in-seam clip 7n 7 24 ga. DMC 15OSS Fixed „ T �8" Clip 8 0 o 16 26 ga. in-seam clip 7 26 ga. DMC 150SS Fixed ,_,,� , Clip 0 0 22 ga.SS in-seam clip 7 7 18 / 16 L L Clips(Cont'd) 22 ga. DMC 150SS Clip 1, T o a d ' 01 3 Y 4 22 ga. in-seam clip 18 1a° 22 ga. DMC 150SS Fixed L Clip 8„ T Q C a �n 3 4 22 ga. base;24 ga.butterfly in-seam clip DMC 150SS Butterfly Clip > 4. DRX15001.7 FL17678-R7 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail 22 ga.base;24 ga.butterfly in-seam clip DMC 15OSS Continuous Butterfly Clip , 26 ga.in-seam clip DMC 150SS Utility o Floating Clip 0 3„ Clips(Cont'd) 18 ga. in-seam clip DMC 175S UL Clip p 22 ga.SS in-seam clip a 1 o DMC 200S Clip � 0 o 0 �/ 3" DRX15001.7 FL17678-R7 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Component Product Installation Detail 18 ga. base;22 ga.butterfly in-seam clip;4.5 in.length DMC 200S Butterfly Clip 18 ga. base;22 ga.butterfly in-seam clip; 120 in.length;top slider 12 in.o.c. DMC 200S Continuous Butterfly Clip { Clips(Cont'd) cY ,i 24 ga. in-seam clip DMC 450 Clip o 24 ga.SS in-seam clip DMC 450SS Clip o Bostik 70-05A Sealants Shall be applied in continuous beads along the seam Bostik Chem-Calk 915 Fastening Details Nomenclature Attachment DMC 10O S PANEL ##10 - 13 PH1 DMC 100NS Standard DRX15001.7 FL17678-R7 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment DMC 10ONS PANEL BDBTII 70-05A ( - 3116" BEADS) f #10 - 13 PHW DMC 100NS Enhanced DMC 150SL PANEL DMC 150SL CLIP #10-13 PHW(2 Per Clip) UNDERLAYMENT DMC 150SL Standard DMC 150SS PANEL DMC 15OSS CONTINUOUS BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT DMC 150SS Continuous SUBSTRATE Butterfly DMC 150SS PANEL DMC 150SS BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 150SS Butterfly DRX15001.7 FL17678-R7 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment DMC 150SS PANEL DMC 15OSS BUTTERFLY CLIP (2)#14- 13 PHDD UNDERLAYMENT W- 18GA BEARING PLATE ISO INSULATION METAL DECK DMC 150SS#14 Butterfly DMC 15OSS PANEL 24 GA DMC 15OSS FIXED CLIP (2)#10-13 PHW UNDERLAYMENT DMC 150SS Fixed-90 SUBSTRATE it NIN'BEAB BOSTIK CHEM.CALK 91 S APPLIED TO BOTH SIDES OF CLIP DMC 15OSS PANEL 24OA DMC h50SS FIXED CLIP 114"BEAD BOSTIK CHEM-CALK 9' APPLIED TO BOTH SIDE OF CLIP DMC 150SS#14 Fixed- 90 2 #14-13 DP1,PH Screws per clip; Clip installed over 18 ga.bearing plate DMC 15OSS PANEL, 24 GA DMC 15OSS CLIP (2)#10- 13 PHW UNDERLAYMENT DMC 150SS Standard(Al) SUBSTRATE DRX15001.7 FL17678-R7 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment 1/4"BEAD BOSTIK 70-05A— DMC 150SS PANEL 22 GA DMC 150SS FIXED CLIP DMC 150SS Fixed N#10-13 PHW Enhanced-90 UNDERLAYMENT SUBSTRATE l DMC 150SS PANEL 22 GA DMC 150SS FIXED CLIP (2)#10- 13 PHW UNDERLAYMENT DMC 150SS Fixed SUBSTRATE Enhanced-180 1/4"BEAD BOSTIK 70-05A DMC 150SS PANEL 22 GA DMC 150SS CLIP (2)#10-13 PHW DMC 150SS Enhanced(Al) UNDERLAYMENT SUBSTRATE DRX15001.7 FL17678-R7 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment DMC 150SS PANEL DMC 15OSS CLIP (2) #10-13 PH Screws UNDERLAYMENT 1 DMC 150SS Zinc SUBSTRATE IV y DMC 175S Panel DMC 175S UL Cip #10-111 PH Screw (2)per cop DMC 175S#10 Standard DMC 175S Panel DMC 1755 UL Clip ffl-13 PH Screw f2l per clip 114"BEAD BOSTIK CHEM-CALK 915 MALE LEG AND BOTH SIDES OF CLIP V9"BEAD B08Tk CHEM-CALK '- DMC 175S#10 Enhanced 915 ON FEMALE LEG DRX15001.7 FL17678-R7 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment DMC 175S PANEL DMC 175S LIL CLIP 014-13 DP1 PHDD(2 Par Clip) 3X3-13GA BEARING PLATE METAL DECK ISO INSULATION ]� DMC 175S#14 Standard DMC 200S PANEL DMC 200S BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 200S Butterfly DMC 200S PANEL DMC 200S BUTTERFLY CLIP #10 - 16 DP3 PHD UNDERLAYMENT METAL DECK DMC 200S Butterfly(Steel) Use 18 ga.bearing plate over polyisocyanurate insulation DRX15001.7 FL17678-R7 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment DMC 200S PANEL DMC 200S CONTINOUS BUTTERLY CLIP #10 - 16 DP3 PHD UNDERLAYMENT METAL DECK DMC 200S Continuous Butterfly(Steel) Use 18 ga.bearing plate over pol isoc anurate insulation DMC 200S PANEL DMC 200S CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 200S Fixed 1/4"BEAD BOSTIK 70-05A DMC 200S PANEL QMC 200S CLIP (2)#10-13 PHW DMC 200S Fixed UNDERLAYMENT Enhanced SUBSTRATE DRX15001.7 FL17678-R7 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Fastening Details Nomenclature Attachment DMC 450 PANEL DMC 450 CLIP #10- 13 PHW(2 Per Clip) DMC 450 Standard I&==27 --- DMC 450 PANEL DMC 450 SS CLIP #10- 13 PHW(2 Per Clip) DMC 450SS Standard p9-15 HWH WOOD SCREW WITH SEALING WASHER DMC 5V Standard DRX15001.7 FL17678-R7 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LL C APPENDIX A Fastening Details Nomenclature Attachment #10- 14 DREXMET WOODSCREW DMC 5V PANEL METSHIELD HT UNDERLAYMENT DMC 5V#10 Standard PLYWOOD DMC 5V PANEL #10-14 DREXMET WOODSCREW UNDERLAYMENT 7I16"OSB MIN. DMC 5V Pan Fastening ONLY REQUIRED AT PANEL ENDS \ 1'-9" COVERAGE #10-15 HWH WOO DSC R EW(DUAL THREAD) 12"o.c. to 36"o.c. MAX. ROW SPACING DMC Corrugated UNDERLAYMENT 15/32" MIN. PLYWOOD ZiL DRX15001.7 FL17678-R7 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy= min.40 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RD1.0& FBC. 6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span. Roof System Numbers and Definitions 100NS-W# DMC 100NS over Wood Deck(New or Existing) 150SL-W# DMC 150SL over Wood Deck(New or Existing) 150SS-S# DMC 150SS over Steel Deck(New or Existing) 150SS-W# DMC 150SS over Wood Deck New or Existing 175S-S# DMC 175S over Steel Deck(New or Existing) 175S-W# DMC 175S over Wood Deck(new or Existing) 200S-S# DMC 200S over Steel Deck(New or Existing) 200S-W# DMC 200S over Wood Deck(New or Existing) 450-W# DMC 450 over Wood Deck(New or Existing) 5V-W# DMC 5V over Wood Deck(New or Existing) COR-W# DMC Corrugated over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 10ONS-W1 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Standard attachment 97 5 CDX plywood Versashield Solo Max. 16-inch wide with fastener spaced 10.5 in.o.c. 100NS-W2 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Standard attachment -120 CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c. 100NS-W3 Min. 15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Enhanced attachment -135 CDX plywood Versashield Solo Max. 16-inch wide with fasteners spaced 5.25 in.o.c. DRX15001.7 FL17678-R7 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SL over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 24 ga. DMC 150SL DMC 150SL Standard attachment 150SL-W1 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -52.5 Approved Systems for DMC 150SS over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-Sl Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 36 in.o.c. -41.7 Grade 80 Steel insulation board Min.22 ga. Min. 1 in.Approved Approved ASTM D 24 ga. DMC 150SS DMC 150SS#14 Fixed-90 attachment 150SS-S2 Type B, As required polyisocyan u rate 1970 underlayment Max. 16-inch wide with clips spaced 16 in.o.c. -71 Grade 80 Steel insulation board Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S3 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 24 in.o.c. -92.4 Grade 80 Steel insulation board Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S4 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 18 in.o.c. -117.8 Grade 80 Steel insulation board Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S5 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 12 in.o.c. -143.1 Grade 80 Steel insulation board Min.22 ga. Min. 1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S6 Type B, As required polyisocyan u rate As required per FBC Max. 16-inch wide with clips spaced 6 in.o.c. -168.5 Grade 80 Steel insulation board DRX15001.7 FL17678-R7 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP(psf) No. 0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment 150SS-Wl Min. 15/32 OPTIONAL Approved ASTM D 150SS with DMC 150SS Utility Floating Clips -78.5 CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide spaced 18 in.o.c. 180'seam 0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment 150SS-W2 Min. 15/32 OPTIONAL Approved ASTM D 150SS with DMC 150SS Utility Floating Clips -86 CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide spaced 6 in.o.c. 180'seam 0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment 150SS-W3 Min. 15/32 OPTIONAL Approved ASTM D 150SS with 26 ga. DMC 150SS Fixed Clips spaced -86 CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide 18 in.o.c. 180'seam Min. 15/32 OPTIONAL 0.032"Al DMC 150SS DMC 150SS Standard(Al)attachment 150SS-W4 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -90 180'seam 150SS-W5 Min. 15/32 OPTIONAL As required per FBC Max. 1 24 ga. DMC 150SS6-inch wide DMC 150SS Fixed-90 attachment CDX plywood Versashield Solo 1 seam with clips spaced 16 in.o.c. 90 DMC 150SS Min. 15/32 OPTIONAL 24 ga. DMC 150SS Butterfly attachment 150SS-W6 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -99.25 180'seam 0.027"(0.7mm)Zinc DMC DMC150SS Zinc attachment 150SS-W7 Min. 15/32 OPTIONAL Approved ASTM D 150SS with 26 ga. DMC 150SS Fixed Clips spaced -108.5 CDX plywood Versashield Solo 1970 underlayment Max. 15.7-inch wide 9 in.o.c. 180'seam Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Continuous Butterfly 150SS-W8 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment with fasteners spaced 12 in.o.c. -114.25 180'seam Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced-90 150SS-W9 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -150 Min.90'seam with clips spaced 12 in.o.c. Min. 15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced- 180 150SS-W10 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -165 Min. 180'seam with clips spaced 8 in.o.c. DRX15001.7 FL17678-R7 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP(psf) No. 032"AlDMC 150SS Min. 15/32 OPTIONAL 0. DMC 150SS Enhanced(Al)attachment 150SS-W11 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -180 180'seam Approved Systems for DMC 175S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved Min.22 ga. 24 ga. DMC 175S DMC 175S#14 Standard attachment 175S-S1 As required polyisocyanu rate As required per FBC -60 Type B Steel insulation board Max. 18 inch wide with clips spaced 36 in.o.c. Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S2 As required polyisocyanu rate As required per FBC -88 Type B Steel insulation board Max. 17.5 inch wide with clips spaced 18 in.o.c. Min.22 ga. Min. 1 in.Approved 24 ga. DMC 175S DMC 175S#14 Standard attachment 175S-S3 As required polyisocyanu rate As required per FBC -105 Type B Steel insulation board Max. 18 inch wide with clips spaced 6 in.o.c. Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S4 As required polyisocyanu rate As required per FBC -129.25 Type B Steel insulation board Max. 17.5 inch wide with clips spaced 12 in.o.c. Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-W1 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 24 in.o.c. -52.5 Solo Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-W2 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 18 in.o.c. -59.4 Solo DRX15001.7 FL17678-R7 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-W3 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 12 in.o.c. -66.4 Solo Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-W4 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 8 in.o.c. -71 Solo Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Enhanced attachment 175S-W5 CDX plywood Versashield Approved ASTM D 1970 underlayment Max. 18-inch wide with clips spaced 12 in.o.c. -71 Solo ASTM D 226,Type II roofing felt attached per 175S-W6 Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -74.75 CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 24 in.o.c. Underlayment self-adhered to felt Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-W7 CDX plywood Versashield As required per FBC Max. 14-inch wide with clips spaced 12 in.o.c. -82.5 Solo Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W8 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 16 in.o.c. -84.25 Solo Min. 19/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W9 CDX plywood Versashield As required per FBC Max. 16-inch wide with clips spaced 25 in.o.c. -97.5 Solo Min. 15/32 OPTIONAL 0.040"Al DMC 175S DMC 175S#10 Standard attachment 175S-W10 CDX plywood Versashield As required per FBC Max. 17.5-inch wide with clips spaced 18 in.o.c. -106.75 Solo Min. 15/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W11 CDX plywood Versashield As required per FBC Max. 18-inch wide with clips spaced 8 in.o.c. -121.75 Solo ASTM D 226,Type II roofing felt attached per 175S-W12 Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 0.032"Al DMC 175S DMC 175S#10 Standard attachment -131 CDX plywood followed by Metshield High-Temp Max. 18-inch wide with clips spaced 6 in.o.c. Underlayment self-adhered to felt Min. 19/32 OPTIONAL 24 ga. DMC 175S DMC 175S#10 Standard attachment 175S-W13 CDX plywood Versashield As required per FBC Max. 16-inch wide with clips spaced 8 in.o.c. -135 Solo DRX15001.7 FL17678-R7 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 200S over Steel Deck(New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved 24 ga. DMC 200S Min.22 ga. DMC 200S Butterfly(Steel)attachment 20OS-S1 As required polyisocyanu rate As required per FBC Max. 16-inch wide -88 Type B Steel insulation board 180°seam with clips spaced 24 in.o.c. Min.22 ga. 24 ga. DMC 200S DMC 200S Butterfly(Steel)attachment 200S-S2 Type B Steel As required None As required per FBC Max. 16-inch wide with clips spaced 24 in.o.c. -91.75 180°seam Min.22 ga. Min. 1 in.Approved 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S3 As required polyisocyanu rate As required per FBC Max. 16-inch wide -121.75 Type B Steel insulation board 180°seam attachment with clips spaced 12 in.o.c. Min.22 ga. 24 ga. DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S4 Type B Steel As required None As required per FBC Max. 16-inch wide attachment with clips spaced 12 in.o.c. -151.75 180°seam Approved Systems for DMC 200S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 20OS-W1 Min.plywood 24 ga. DMC 200S OPTIONAL As required per FBC Max. 16-inch wide DMC 200S Butterfly attachment -67.5 CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c. 200S-W2 Min.plywood 0.040"Al DMC 200S OPTIONAL As required per FBC Max. 16-inch wide DMC 200S Butterfly attachment 75 CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c. 040"AlDMC 200S Min. 19/32 OPTIONAL 0. DMC 200S Fixed attachment 200S-W3 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -105 180°seam 200S-W4 Min. 19/32 OPTIONAL As required per FBC Max. 16-inch wide 0.040"Al DMC 200S DMC 200S Fixed Enhanced attachment -180 CDX plywood Versashield Solo 180°seam with clips spaced 8 in.o.c. DRX15001.7 FL17678-R7 Page 6 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 450 over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 450-W1 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment -30 CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 24 in.o.c. Min. 15/32 OPTIONAL 0.032"Al DMC 450 DMC 450SS Standard attachment 450-W2 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. 45 450-W3 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment -67.5 CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 15.5 in.o.c. 450-W4 Min. 15/32 OPTIONAL As required per FBC 0.032"Al DMC 450 DMC 450SS Standard attachment 75 CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c. 450-W5 Min. 19/32 OPTIONAL As required per FBC 24 ga. DMC 450 DMC 450 Standard attachment 82 5 CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c. Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) ASTM D 226,Type II roofing felt attached per 0.032"Al DMC 5V OPTIONAL DMC 5V#10 Standard attachment Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W1 CDX plywood Approved fire barrier or insulation followed by Metshield High-Temp Max.24-inch with#10 w4 HWH wood screws with -56 Underlayment self-adhered to felt coverage sealing washers spaced 18 in.o.c. 26 ga. DMC 5V OPTIONAL DMC 5V Standard attachment Min. 15/32 Min.21-inch to 5V-W2 CDX plywood Approved fire barrier As required per FBC Max.24-inch with#9-15 HWH wood screws with -60 or insulation coverage sealing washers spaced 16 in.o.c. ASTM D 226,Type II roofing felt attached per 26 ga. DMC 5V OPTIONAL DMC 5V#10 Standard attachment Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W3 CDX plywood Approved fire barrier or insulation followed by Metshield High-Temp Max.24-inch with#10 w4 HWH wood screws with 71 Underlayment self-adhered to felt coverage sealing washers spaced 24 in.o.c. DRX15001.7 FL17678-R7 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) 26 ga. DMC 5V OPTIONAL DMC 5V Pan Fastening attachment 5V-W4 Min.7/16 OSB Approved fire barrier As required per FBC Min.21-inch to with#10-14 HWH wood screws with -75 plywood or insulation Max.24-inch sealing washers spaced 16 in.o.c. coverage 26 ga. DMC 5V OPTIONAL DMC 5V Pan Fastening attachment 5V-W5 Min.7/16 OSB Approved fire barrier As required per FBC Min.21-inch to with#10-14 HWH wood screws with -112.5 plywood or insulation Max.24-inch sealing washers spaced 8 in.o.c. coverage 26 ga. DMC 5V OPTIONAL DMC 5V Standard attachment Min. 15/32 Min.21-inch to 5V-W6 CDX plywood Approved fire barrier As required per FBC Max.24-inch with#9-15 HWH wood screws with -121.75 or insulation sealing washers spaced 8 in.o.c. coverage ASTM D 226,Type II roofing felt attached per 26 ga. DMC 5V or OPTIONAL 0.032"Al DMC 5V DMC 5V#10 Standard attachment Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 5V-W7 Approved fire barrier Min.21-inch to with#10-14 HWH wood screws with -206 CDX plywood or insulation followed by nt self ad High-Temp Max.24-inch sealing washers spaced 6 in.o.c. Underlayment self-adhered to felt coverage Approved Systems for DMC Corrugated over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) Min. 15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment COR-W1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min. 15/32 OPTIONAL 26 ga. DMC Corrugated DMC 5V Corrugated attachment COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage With#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min. 15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment COR-W3 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -135 or insulation and sealing washer spaced 12 in.o.c. Min. 15/32 OPTIONAL 26 ga. DMC Corrugated DMC 5V Corrugated attachment COR-W4 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -150 or insulation and sealing washer spaced 12 in.o.c. DRX15001.7 FL17678-R7 Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd=0.85 8. Vot is shown in the tables below. Design wind loads are calculated using Vasd=V,,itA.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e,Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10% of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller, but not less than either 4%of the least horizontal dimension or 3ft Gable Hip a X _ 3 2 3 3 2 3 a \ 3 2 3 a 2 1 2 2 1 2 2 1 2 2 1 2 3 2 3 3 2 3 a 3 2 3 a a Iola la al al- DRX15001.7 FL17678-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure B(Roof slope between 2:12 and 12:12 Mean Basic Wind Speed mph Building Type Zone Roof 120 130 140 150 160 170 180 190 200 Height(ft) 20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6 25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3 1 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7 40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5 50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2 60 -34.8 -40.9 -47.4 -54.4 1 -61.9 -69.9 -78.4 -87.3 -96.8 20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0 25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3 Enclosed/ 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3 Partially Open 2 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2 50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4 25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3 3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2 40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0 50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9 60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8 20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6 25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2 1 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2 40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2 50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9 60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2 20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0 25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2 Partially 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8 Enclosed 2 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9 50 -54.1 1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 1 -150.2 60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6 20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4 25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2 3 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7 40 -59.3 -69.6 1 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7 50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6 60 -66.3 1 -77.8 -90.3 1 -103.6 1 -117.9 1 -133.1 -149.2 1 -166.3 1 -184.2 DRX15001.7 FL17678-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure C(Roof slope between 2:12 and 12:12 Mean Basic Wind Speed(mph) Building Type Zone Roof 120 130 140 150 160 170 180 190 200 Height(ft) 20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5 25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 1 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6 40 42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4 50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1 60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7 20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5 25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1 Enclosed/ 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8 Partially Open 2 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7 50 1 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 1 -163.4 -181.0 60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6 3 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5 40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3 50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2 60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1 20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9 25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2 1 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5 40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5 50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2 60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5 20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9 25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3 Partially 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7 Enclosed 2 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8 50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1 60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5 20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1 25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7 3 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4 40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4 50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2 60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9 DRX15001.7 FL17678-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure D(Roof slope between 2:12 and 12:12 Mean Basic Wind Speed mph Building Type Zone Roof 120 130 140 150 160 170 180 190 200 Height(ft) 20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0 25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5 1 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1 40 50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9 50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6 60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1 20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4 25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0 Enclosed/ 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6 Partially Open 2 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6 50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9 60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6 20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2 25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1 3 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0 40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8 50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7 60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6 20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8 25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2 1 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5 40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5 50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1 60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5 20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2 25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6 Partially 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1 Enclosed 2 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2 50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5 60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9 20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1 25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7 3 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4 40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4 50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2 60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9 DRX15001.7 FL17678-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.