HomeMy WebLinkAboutProductapprovalGAPunderlyment MIAMFDiADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
►�'WY 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
G.A.P. Roofing,Inc.
4444 Hunt Street
Pryor, OK 74361
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: G.A.P. Roofing Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 20-0908.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.:21-0406.03
MIAMMADE COUNTY Expiration Date: 07/03/24
Approval Date: 08112/21
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test Product
Product Dimensions Specification Description
WaterGuard Rain&Ice 3' x 66' rolls ASTM D1970 Self-adhering,woven fiberglass mat
Manufacturing Location #I Nominal 48 mil. reinforced membrane with a SBS polymer
modified asphalt top coating and surfaced
with a sand release agent.
WaterGuard Self-Adhered 3' x 66' rolls ASTM D1970 Flexible, fiberglass reinforced, self-adhering
MetalGuard HT Nominal 75 mil. rubberized asphalt membrane with a
Manufacturing Location#1 polymer film on the surface and a removable
treated release film on the adhesive side.
WaterGuard Self-Adhered 39-3/8"x 61' rolls TAS 103 Flexible,fiberglass reinforced, self-adhering
MetalGuard HT MW Nominal 75 mil. ASTM D1970 rubberized asphalt membrane with a
Manufacturing Location #1 polymer film on the surface and a removable
treated release film on the adhesive side.
WaterGuard Self-Adhered 3' x 66' rolls ASTM D1970 SBS polymer modified,reinforced,
MetalGuard Trax Nominal 75 mil. synthetic-surfaced metal underlayment with
Manufacturing Location #1 a removable siliconized split release film on
the adhesive side.
WaterGuard Self-Adhered 39-3/8"x 61' rolls TAS 103 Self-adhering, non-woven fiberglass mat
TileGuard HT Nominal 80 mil. ASTM D1970 with dual SBS polymer modified High Temp
Manufacturing Location#1 underlayment for use on tile and metal roofs.
WaterGuard Self-Adhered 39-3/8"x 61' rolls TAS 103 Self-adhering,non-woven fiberglass mat
TileGuard Ultra Nominal 80 mil. ASTM D1970 with dual SBS polymer modified High Temp
Manufacturing Location #I underlayment for use on tile and metal roofs.
#43 Organic Base Sheet 36"x 72"rolls ASTM D2626 Saturated with asphalt and then coated
Manufacturing Location#2 on both sides with weathering grade coating
asphalt and then covered on top with mineral
surface fines to prevent sticking in the roll.
MANUFACTURING LOCATION
1.Pryor, OK.
2. Shaftner,CA
NOA No.:21-0406.03
CMILAWD�ADEC4UN� Expiration Date: 07/03/24
Approval Date: 08/12/21
Page 2 of 5
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials GAPR-014-02-01 ASTM D1970 06/20/17
Technologies LLC GAPR-018-02-01 ASTM D1970 09/27/17
GAPR-029-02-01 ASTM D1970 06/19/18
GAPR-030-02-01 ASTM D1623 01/25/19
GAPR-034-02-01 ASTM D1623 03/01/19
GAPR-034-02-02.1 TAS 103/TAS I10 08/28/20
1047T0001.1 ASTM D1970 08/28/19
1047T0004.1 TAS 103/TAS 110 08/28/20
1047T0017 ASTM D1970 03/06/20
1047T0020 ASTM D1970/TAS 110 07/22/20
ASTM D4798
1047T0011 TAS 103/TAS 110 01/06/20
1047T0012 TAS 103/TAS 110 01/30/20
1047T0019 TAS 103 07/22/20
1047T0022.1 TAS 103 08/09/21
1047T0035 TAS 103 03/03/21
1047T0039 ASTM D2626 03/03/21
1047T0040 ASTM D1970 05/17/21
1047T0041.1 TAS 103/TAS 110 08/09/21
APPROVED ASSEMBLIES
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered and backnailed.
Base Sheet: One or more plies of ASTM D 226 Type II or 443 ORGANIC BASE SHEET or ASTM D 2626
with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved nails
and tin caps 6" o.c. at the laps and two staggered rows 12"o.c. the field of the roll.
Membrane: One or more plies of WaterGuard Rain&Ice, WaterGuard Self-Adhered MetalGuard HT MW,
WaterGuard Self-Adhered MetalGuard HT or WaterGuard Self-Adhered MetalGuard Trax
underlayment with a minimum 4"side lap and minimum 6"end lap staggered min. 6' from the
preceding course or one or more plies of WaterGuard Self-Adhered TileGuard HT or
WaterGuard Self-Adhered TileGuard Ultra underlayment with a minimum 4"side lap and
minimum 6" end lap staggered min. 6' from the preceding course. WaterGuard Self-Adhered
TileGuard HT end laps shall be sealed with Mule-Hide 4420 Mod Bit Adhesive—Brush Grade or
Mule-Hide#421 Mod Bit Flashing Adhesive—Trowel Grade or similar product.
Surfacing: Approved Roof Assemblies. See Limitations#3,#4, #5 and#6.
NOA No.: 21-0406.03
MIAMMADEC0 j Expiration Date: 07/03/24
Approval Date: 08/12/21
Page 3 of 5
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WaterGuard Rain& Ice, WaterGuard Self-Adhered MetalGuard HT, WaterGuard Self-
Adhered MetalGuard HT MW, WaterGuard Self-Adhered MetalGuard Trax,WaterGuard Self-Adhered TileGuard
HT and WaterGuard Self Adhered TileGuard Ultra underlayments and#43 ORGANIC BASE SHEET shall be
installed in strict compliance with applicable Building Code.
3. WaterGuard Self-Adhered MetalGuard HT,WaterGuard Self-Adhered MetalGuard HT MW,WaterGuard Self-
Adhered MetalGuard Trax, WaterGuard Self-Adhering TileGuard HT and WaterGuard Self Adhered TileGuard
Ultra underlayments may be used with mechanically fastened metal roofing, slate shingles, asphalt shingles,
photovoltaic shingles,and composite plastic shingles.
4. WaterGuard Rain&Ice underlayments may be used with mechanically fastened slate shingles,asphalt shingles,
photovoltaic shingles, and composite plastic shingles.
5. WaterGuard Self-Adhered TileGuard HT underlayment may be used with mechanically fastened clay and concrete
roof tiles or clay and concrete roof tiles set in,DuPont de Nemours,Inc. TILE BONDTm Roof Tile Adhesive,DAP
Touch'n Seal Storm Bond Roof Tile Adhesive or ICP Adhesives Polyset AH-160.
6. WaterGuard Self-Adhered TileGuard Ultra and WaterGuard Self-Adhered MetalGuard HT MW underlayments
may be used with mechanically fastened clay and concrete roof tiles.
7. Head laps for tile underlayments used with adhered clay or concrete tile shall be back nailed 12"o.c. with approved
nails and tin cups or by prefabricated fasteners. Head laps for tile underlayments used with mechanically fastened
clay or concrete tile may be optionally back nailed 12"o.c, with approved nails and tin cups or by prefabricated
fasteners.
8. WaterGuard Self-Adhered TileGuard HT or WaterGuard Self-Adhered TileGuard Ultra underlayment shall only be
used on assemblies with a maximum roof slope of 6:12 when the roof tiles are placed directly on the underlayment.
Tiles shall be placed on battens for roof slopes greater than 6:12. .
9. WaterGuard MetalGuard HT MW underlayment shall only be used with tile assemblies installed on battens.
10. WaterGuard Rain&lee,WaterGuard Self-Adhered MetalGuard HT,WaterGuard Self-Adhered MetalGuard HT
MW,WaterGuard Self-Adhered MetalGuard Trax,WaterGuard Self-Adhering TileGuard HT and WaterGuard
Self-Adhered TileGuard Ultra underlayments shall not be applied over an existing roof membrane as a recover,but
may be applied over a roofing Base/Anchor sheet underlayment.
11. WaterGuard Self-Adhered MetalGuard HT underlayment and 443 ORGANIC BASE SHEET shall not be left
exposed as a temporary roof for longer than 30 days of application.
12. WaterGuard Rain&Ice and WaterGuard Self-Adhered TileGuard Ultra underlayment, shall not be left exposed as
a temporary roof for longer than 90 days of application.
13. WaterGuard Self-Adhered MetalGuard Trax underlayment shall not be left exposed as a temporary roof for longer
than 120 days of application
14. WaterGuard Self-Adhered TileGuard HT and WaterGuard Self-Adhered MetalGuard HT MW underlayments shall
not be left exposed as a temporary roof for longer than 180 days of application.
15. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
NOA No.:21-0406.03
MIARRDADECOUNTY Expiration Date: 07/03/24
Approval Date: 08/12/21
Page 4 of 5
LIMITATIONS: (CONTINUED)
16. WaterGuard Rain&Ice, WaterGuard Self-Adhered MetalGuard HT MW,WaterGuard Self-Adhered MetalGuard
HT, WaterGuard Self-Adhered MetalGuard Trax,WaterGuard Self-Adhered TileGuard HT and WaterGuard Self-
Adhered TileGuard Ultra underlayments and 443 ORGANIC BASE SHEET may be used with any approved roof
covering Notice of Acceptance listing WaterGuard Rain&Ice,WaterGuard Self-Adhered MetalGuard HT MW,
WaterGuard Self-Adhered MetalGuard HT, WaterGuard Self-Adhered MetalGuard Trax,WaterGuard Self-
Adhered TileGuard HT and WaterGuard Self-Adhered TileGuard Ultra underlayments and#43 ORGANIC BASE
SHEET as a component part of an assembly in the Notice of Acceptance. If WaterGuard Rain&Ice,WaterGuard
Self-Adhered MetalGuard HT MW, WaterGuard Self-Adhered MetalGuard HT, WaterGuard Self-Adhered
MetalGuard Trax,WaterGuard Self-Adhered TileGuard HT and WaterGuard Self-Adhered TileGuard Ultra
underlayments and#43 ORGANIC BASE SHEET are not listed, a request may be made to the Authority Having
Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate
documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
17, WaterGuard Rain&Ice, WaterGuard Self-Adhered MetalGuard HT MW, WaterGuard Self-Adhered MetalGuard
HT, WaterGuard Self-Adhered MetalGuard Trax, WaterGuard Self-Adhered TileGuard HT and WaterGuard Self-
Adhered TileGuard Ultra underlayments and#43 ORGANIC BASE SHEET shall be applied to a smooth, clean and
dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re-
fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
18. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
19. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas. Special attention to ensure additional pressure/bonding to any non-selvedge edge overlap.
20. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
21. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape(target) shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of WaterGuard Rain&Ice,
WaterGuard Self-Adhered MetalGuard HT MW,WaterGuard Self-Adhered MetalGuard HT, WaterGuard Self-
Adhered MetalGuard Trax, WaterGuard Self-Adhered TileGuard HT and WaterGuard Self-Adhered TileGuard
Ultra underlayments shall be applied over the underlayment.
22. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
23. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product
Control Seal as shown below.
QMIAMMI-DAMDE COUNTY
, . . . �
END OF THIS ACCEPTANCE
NOA No.: 21-0406.03
MIAMI•DADECOUNTY Expiration Date: 07/03/24
Approval Date: 08/12/21