Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutFL13192_R6_II_HardiePlank-Install-Instr_2022 Florida Product Approval
HardiePlank® Lap Siding
• For use inside HVHZ:
o HardiePlank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with the Miami-Dade County Florida NOA 20-
0730.06. Consult the HardiePlank product installation instructions on the
follow pages for all other installation requirements.
• For use outside of HVHZ,
o HardiePlank Lap Siding fastener types, fastening schedule, and installation
shall be in accordance with CAE Engineering Reports No.:2001-10.2.1,
2001-10.2.21 2001-10.2.3. Consult the HardiePlank product installation
instructions on the follow pages for all other installation requirements.
AId1ll���i
TJ: B1Fc�
•
HardiePlank' Lap Siding
- �J►TE Df .' ir!
�ja(�� 7- I`>( J ZO EFFECTIVE DECEMBER 2019
-.. \
71
IMPORTANT:FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUt'�TImiNNIA AMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS,AFFECT
BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE.FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING
THIS PRODUCT MAY RESULT IN PERSONAL INJURY.BEFORE INSTALLATION,CONFIRM YOU ARE USING THE CORRECT HARDIEZONE®PRODUCT INSTRUCTIONS BY VISITING
HARDIEZONE.COM OR CALL 1-866-942-7343(866-9-HARDIE)
p CUTTING INSTRUCTIONS
STORAGE & HANDLING: OUTDOORS INDOORS
1.Position cutting station sothat airflow blows dust awayfrom the DO NOT grind or cut with a power saw indoors.Cut using shears(manual,pneumaticor
Store flat and keep dry and covered prior to user and others near the cutting area. electric)orthe score and snap method,not recommended for products thickerthan 7/16ir.
installation.Installing siding wet or saturated may 2.Cut using one ofthe following methods:
result in shrinkage butt joints.Car tanks on a.Best:Circular saw equipped with a HardieBlade®saw blade
9 1 Carry and attached vacuum dust collection system.Shears DO NOT drysweepdust;use wet dust suppression orvacuum to collect dust.
edge.Protect edges and corners from breakage. (manual,pneumaticorelectric)mayalso be used,not For maximum dust reduction,James Hardie recommends using the'Best"cutting
James Hardie is not responsible for damage caused recommended for products thickerthan7/16 in. practices.Always follow the equipment manufacturer's instructions for proper operation.
by improper storage and b.Better: Circular saw®equipped with a dust collection feature For best performance when cutting with a circular saw,James Hardie recommends
(e.g.Roan saw)and a HardieBlade saw blade. using HardieBlade®sawblades.
handling of the c.Good:Circular saw equipped with a HardieBlade saw blade.
product. Gotojameshardiepros.comforadditionaI cutting and dust control recommendations.
IMPORTANT:The Occupational Safety and Health Administration(OSHA)regulates workplace exposure to silica dust.For construction sites,OSHA has deemed
that cutting fiber cement with a circular saw having a blade diameter less than 8 inches and connected to a commercially available dust collection system per
manufacturer's instructions results in exposures below the OSHA Permissible Exposure Limit(PEL)for respirable crystalline silica,without the need for additional
respiratory protection.
Ifyou are unsure about howto complywith OSHAsilica dust regulations,consult a qualified industrial hygienist orsafety professional,orcontactyourJames
Hardie technical sales representative for assistance.James Hardie makes no representation or warranty that adopting a particular cutting practice will assure
your compliance with OSHA rules or other applicable laws and safety requirements.
GENERAL REQUIREMENTS:
- HardiePlank®lap siding can be installed over braced wood orsteel studs,20 gauge(33 mils)minimum to 16 gauge(54 mils)maximum,spaced a maximum of24 in o.c.ordirectlyto
minimum 7/16 in thick OSB sheathing.See General Fastening Requirements.Irregularities in framing and sheathing can mirror through the finished application.Correct irregularities
before installing siding.
o Information on installing James Hardie products over non-nailable substrates(ex:gypsum,foam,etc.)can be located in J H Tech Bulletin 19 atwww.jamehardie.com
- A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing
in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.James Hardie does manufacture HardieWrap®Weather Barrier,a
non-woven non-perforated housewrap',which complies with building code requirements.
- When installing James Hardie products all clearance details in figs.3-14 must be followed. Double Wall Figure 1 Single Wall
- Adjacentfi nished grade must slope awayfrom the building in accordance with local building codes-typicallya minimum Construction Construction
of 6 in.in the first 10 ft.. water-resistive let-in bracing
o Do not use HardiePlank lap siding in Fascia or Trim applications. barrier plywood or 24 in.o.c.max.
- Do not install James Hardie products,such thatthey may remain in contactwith standing water. OSB sheathing
- HardiePlank lap siding may be installed on flat vertical wall applications only.
o For larger projects,including commercial and multi-family projects,where the span ofthe wall is
significant in length,the designer and/or architect should take into consideration the coefficient ofthermal expansion and
moisture movement ofthe product intheirdesign.Thesevalues can befound intheTechnical Bulletin"Expansion
Characteristics of James Hardie®Siding Products"at www.jameshardie.com.
-James Hardie Building Products provides installation/wind load information for buildings with a maximum mean roof
height of 85 feet.For information on installations above 60 feet,please contact J H technical support.
INSTALLATION: JOINT TREATMENT Figure
One or more ofthefollowingjointtreatment options are °
required by code(as referenced 2018 IRC R703.10.2) stud preslent,(placeil lfastener
°
A.Joint Flashing(James Hardie recommended) between 3/4 in.&1 in. °° o° water-resistive
B.Caulking'(Caulking is not recommended from top of plank) °° ,°° barrier
for ColorPlusforaesthetic reasons as the Caulking Nail3/8in.from ° fastener
and ColorPlus will weather edge of plank ��
joint Leave appropriate gap ° Installa11/4in.starterstripto
differently.Forthe same reason, flashing ensure a consistent plank angle
do not caulk nail heads on Install planks in planks and trim,then caulk'
products.) moderate contact
ColorPlus
p ) at butt joints //JJ�\
C."H"jointercover ��/{/J.Jamesriardie"
Note:Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus.'Refer to Caulking section in these' ions.
'For additional information on HardieWrap®Weather Barrier,consult James Hardie at 1-866-4Hardie or www.hardiewrap.com
SELECT CEDARMILL®1 SMOOTH I BEADED CEDARMILL®I BEADED SMOOTH I CUSTOM COLONIAL SMOOTH®1 CUSTOM COLONIAL-ROUGHSAWN
Visitjameshardiepros.comforthe most recentversion. HS11119 P1/4 12/19
HardiePlank®Lap Siding
CLEARANCE AND FLASHING REQUIREMENTS
Figure 3 Figure 4 Figure 5 Figure 6
RooftoWall Horizontal Flashing Kickout Flashing Slabs, Path, Steps to Siding
MDo
nbylRCcode
srequired
LiL
in4in.Ain.
Min.
1 in.
Figure7 Figure8 Figure Figure 10 Figure11
Deck to Wall Ground to Siding Gutterto Siding Sheltered Areas Mortar/Masonry
-Flashing
Z'Flashing
Z-Fla hing Flas ling
in. 1
Min.
6 in. Jin
i 4 in.
Figure 12 Figure 13 Figure 14
Drip Edge Block Penetration Valley/Shingle Extension
Recommended in HZ10
Z-FI g
Min.'/
caulk
FASTENER REQUIREMENTS*
Referto the applicable ESR report online to determine which fastener meets your wind load design criteria.
Blind Nailing is the preferred method of installation for HardiePlank®lap siding products.Face nailing should only be used where required by code for high wind areas and must not
be used in conjunction with Blind nailing(Please see JH Tech bulletin 17 for exemption when doing a repair).
BLIND NAILING FACE NAILING
Nails-Wood Framing Nails-Wood Framing
-Siding nail(0.09 in.shank x 0.221 in.HD x 2 in.long) •6d(0.113in.shankx0.267in.HDx2in.long)
-11 ga.roofing nail(0.121 in.shank x 0.371 in.HD x 1.25 in.long) •Siding nail(0.09"shank x 0.221"HD x 2"long)
Screws-Steel Framing Screws-Steel Framing
•Ribbed Wafer-head or equivalent(No.8 x 1 1/4 in.long -Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8 in.long x
x 0.375 in. HD)Screws must penetrate 3 threads into metal framing. 0.323 in. HD)Screws must penetrate 3 threads into metal framing.
Nails-Steel Framing Nails- Steel Framing
-ET&F Panelfasf nails orequivalent(0.10 in.shankx0.313 in.HD x 1-1/2 in.long) -ET&F pin or equivalent(0.10 in.shank x 0.25 in.HD x 1-1/2 in.long)
Nails must penetrate minimum 1/4 in.into metal framing. Nails must penetrate minimum 1/4 in.into metal framing.
OSB minimum 7/16 in. OSB minimum 7/16 in.
•Siding nail(0.09 in.shank x 0.215 in.HD x 1-1/2 in.long -Siding nail(0.09 in.shank x 0.221 in.HD x 1-1/2 in.long)
-Ribbed Wafer-head or equivalent(No.8 x 1 5/8 in.long x 0.375 in.HD).
`Also see General Fastening Requirements;and when considering alternative fastening options referto James Hardie's Technical Bulletin USTB 5-Fastening Tips for HardiePlank Lap Siding.
HS11119 P2/4 12/19
HardiePlank'Lap Siding
FASTENER REQUIREMENTS continued
24" -----
Figure 15 Figure 16 St d - O.C.max
Stud 24' �� dill
O.C.max Joint 1 1/4"min.
Minimum overlap Flashing ��w++�— Overlap
for Both Face
DOW—*.& ~r and Blind Nailing
� Nail Line ---
3/4"II-1" --
Blind Nail R ---
min.1 1/4 in. Y o
overlap Face Nail
Water Resistive
Water Resistive Barrier
1 1/4"min. Barrier
Overlap
Laminate sheet to be removed immediately after installation of each course for ColorPluso products.
IPin-backed corners may be done foraesthetic purposes only.Finish nails are recommended for pin-backs.Headed siding nails are allowed.Place pin-backs
no closerthan 1 in.from plank ends and 3/4 in.from plankedge into min.3/8 in.wood structural panel.Pin-backs are not substitute for blind orrface nailing.
GENERAL FASTENING REQUIREMENTS PNEUMATIC FASTENING
Fasteners must be corrosion resistant,galvanized,or stainless steel.Electro-galvanized James Hardie productscan behand nailed orfastenedwitha pneumatictool.
are acceptable but may exhibit premature corrosion.James Hardie recommends the Pneumatic fastening is highly recommended.Set air pressure so that the
use of quality,hot-dipped galvanized nails.James Hardie is not responsible forthe fastener is driven snug with the surface of the siding.A flush mount
corrosion resistance of fasteners.Stainless steel fasteners are recommendedwhen attachmenton the pneumatictool is recommended.Thiswill helpcontrolthe
installing James Hardie®products near the ocean,large bodies of water,or in very depththe nail isdriven.Ifsettingthe nail depth
humid climates. proves difficult,choose a setting that underdrives
Manufacturers ofACQ and CA preservative-treated wood recommend spacer materials the nail.(Drive u hammer
nails s ot apug ply
a
orother h sical barriersto prevent preservative-treated smooth faced hammer i Does not apply for
P Y P P SNUG FLUSH installation to steel framing).
wood and aluminum products.Fasteners used to attach HardieTrim Tabsto preserva-
tive-treated wood shall be of hotdipped zinc-coated galvanized steel orstainless steel
and in accordance to 2018 IRC R317.3 or 2018 IBC 2304.10.5. DO NOT DO NOT DO NOT USE
Consult applicable product evaluation or listing for correct fasteners type and
placement to achieve specified design wind loads. \1JY & S
NOTE:Published wind loads may not be applicable to all areas where Local Building
Codes have specific jurisdiction.Consult James Hardie Technical Services if you are UNDER OVER SLANT ALUMINUM
unsure of applicable compliance documentation. DRIVE DRIVE FASTENERS
- Drive fasteners perpendicular to siding and framing.
- Fastener heads should fit snug against siding(no air space). IF,THEN IF,THEN ADDITIONAL NAIL
-NOTE:Whenever a structural member is present,HardiePlank should be fastened with
even spacing tothe structural member.Thetables allowing directto OSB orplywood WOOD STEEL FACE
should only be used when traditional framing is not available. FRAME FRAME NAIL CLIPPED
HEAD NAILS
CUT EDGE TREATMENT S7111 /�\
Caulk,paint or prime all field cut edges.James Hardie touch-up kits are requ i red to [►\y
touch-up ColorPlus products. �y
COUNTERSINK STAPLES
CAULKING HAMMER &FILL
FLUSH
For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, REMOVE&
Class 25 or higher or a Latex Joint Sealant complying with ASTM C834.Caulking/Sealant REPLACE
must be applied in accordance with the caulking/sealant manufacturer's written instructions.
Note:some caulking manufacturers do not allow"tooling".
PAINTING
DO NOT use stain,oil/alkyd base paint,orpowdercoating on James Hardie®Products.Factory-primed James Hardie products must be painted within 180 days of installation.
100%acrylictopcoats are recommended.Do not paint when wet.For application rates referto paint manufacturers specifications.Back-rolling is recommended ifthe siding
is sprayed.
HS11119 P3/412/19
HardiePlank®Lap Siding
COLORPLUS®TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
-Care should betaken when handling and cutting James Hardie®ColorPlus®products.During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product,then rinse with a garden hose.
-Touch up nicks,scrapes and nail heads using the ColorPlus°Technology touch-up applicator.Touch-up should be used sparingly.
If large areas require touch-up,replace the damaged area with new HardiePlank®lap siding with ColorPlus®Technology.
-Laminate sheet must be removed immediately after installation of each course.
-Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlus®product dealer.
-Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer.
Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problemswith appearance or performance arisingfrom useof third partytouch-up paints orpaints used as touch-up that are notJames Hardie touch-up will not be covered
under the James Hardie ColorPlus Limited Finish Warranty.
PAINTING JAMES HARDIE°SIDING AND TRIM PRODUCTS WITH COLORPLUS°TECHNOLOGY
When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application:
- Ensure the surface is clean,dry,and free of any dust,dirt,or mildew
- Repriming is normally not necessary
- 100%acrylic topcoats are recommended
- DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie®Products.
- Applyfinish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature
- DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section
COVERAGE CHART/ESTIMATING GUIDE
Number of 12 ft. planks, does not include waste
COVERAGE AREA LESS OPENINGS HARDIEPLANK°LAP SIDING WIDTH
SQ 51/4 61/4 7114 71/2 8 81/4 91/4 91/2 12
(1sQ=1oosq.ft.) (exposure) 4 5 6 61/4 63/4 7 8 81/4 10314
1 25 20 17 16 15 14 13 13 9
2 50 40 33 32 30 29 25 25 19
3 75 60 50 48 44 43 38 38 28
4 100 80 67 64 59 57 50 50 37
5 125 100 83 80 74 71 63 63 47
6 150 120 100 96 89 86 75 75 56
7 175 140 117 112 104 100 88 88 65
8 200 160 133 128 119 114 100 100 74
9 225 180 150 144 133 129 113 113 84
10 250 200 167 160 148 143 125 125 93
11 275 220 183 176 163 157 138 138 102
12 300 240 200 192 178 171 150 150 112
13 325 260 217 208 193 186 163 163 121
14 350 280 233 224 207 200 175 175 130
15 375 300 250 240 222 214 188 188 140
16 400 320 267 256 237 229 200 200 149
17 425 340 283 272 252 243 213 213 158
18 450 360 300 288 267 257 225 225 167
19 475 380 317 304 281 271 238 238 177
20 500 400 333 320 296 286 250 250 186
This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibilityfor overor under
ordering of product.
HS11119 P4/4 12/19
DANGER:May cause cancer if dust from product is inhaled.Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust from product.Refer to the current product Safety Data Sheet before use.
The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting,machining,drilling,routing,sawing,crushing,or otherwise abrading fiber cement,and when cleaning
up,disposing of or moving the dust.When doing any of these activities in a manner that generates dust you must(1)comply with the OSHA standard for silica dust and/or other applicable law,(2)follow James Hardie cutting
instructions to reduce or limit the release of dust;(3)warn others in the area to avoid breathing the dust;(4)when using mechanical saw or high speed cutting tools,work outdoors and use dust collection equipment;and(5)if no
other dust controls are available,wear a dust mask or respirator that meets NIOSH requirements(e.g.N-95 dust mask).During clean-up,use a well maintained vacuum and filter appropriate for capturing fine(respirable)dust or use
wet clean-up methods-never dry sweep.
AWARNING:This product can expose you to chemicals including respirable crystalline silica,which is known to the State of California to cause cancer.For more information go to P65Warninc s.ca.00v.
RECOGNITION:I In accordance with ICC-ES Evaluation Report ESR-2290,HardiePlank®lap siding is recognized as a suitable alternate to that specified in the 2006,2009,2012&2015 International Residential Code for One and Two-Family
Dwellings,and the 2006,2009,2012&2015 International Building Code.HardiePlank lap siding is also recognized for application in the following:City of Los Angeles Research Report No.24862,State of Florida Product Approval FL#13192,
Miami-Dade County Florida NOA No.17-0406.06,U.S.Dept.of HUD Materials Release 1263f,Texas Department of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,and California DSA PA-019.These documents should
also be consulted for additional information concerning the suitability of this product for specific applications.
©2018James Hardie Building Products,Inc.All rights reservedTM,SMand@ Product warranties,safety information and additional installation SJamesHardiem
denote trademarks or registered trademarks of James Hardie Technology Limited. information are available at jameshardiepros.com