HomeMy WebLinkAboutLetter To Permit Applicant-ti
Joe Cicio
From: Joe Cicio
Sent: Wednesday, December 11, 2013 8:20 AM
To: MACK@MEL-RY.COM
Cc: Joe Cicio
Subject: Permit Number # 1310-0359
Attachments: Repo rt_FL_Review_Comments_NoncompIiantjrf[1].pdf
Dear St. Lucie County Permit Applicant,
Please see the attached plan review comments which have been generated for your permit. As soon as we receive the
modified plans and any additional required documentation back from the design professional , contractor or owner we
will perform the additional reviews as necessary in order to complete :the plan review process. Once the plans have
been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to
permitting for permit issuance.
Thank you,
�osep� M. Udo,
Plans Examiner If
Standard Building Inspector
Building Plans Examiner
One and Two Family Dwellinglnspector
One and Two Family Plans Examiner
St. Lucie County Planning and Development Services
772-462--1553
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
PROPERTY INFORMATION
Address: 10725 S Ocean Dr 99
City / State / Zip: Jensen Beach, FI 34957
Parcel #: 4511-501-0302-000/6
Zoning: HIRD
APPLICATION INFORMATION
Permit Number: 1310-0359
Permit Type: BUILDING RESIDENTIAL (SFR)
Owner(s):
Elaine I. Peterson / Paul D Peterson
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 5
Stories:
CONTRACTOR INFORMATION
Contractor Name: Mack Matos
Business Name: Mel-Ry Construction X
Business Addr: 10967 S Ocean Dr
City / State / Zip: Jensen Beach, FI 34957 2 G
.111'
REVIEWS AND COMMENTS
Block:
Automatic Sprinkler System? No
Fax Number: 772-229-9440
Email: Mack@Mel-Ry.Com
Review Tvoe
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING
Comment:
THE CONTRACTOR/AGENT IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO IN FILE AT TIME OF PICK
11/5/2013
UP.
11/13/2013 Comment:
VEG PERMIT FILED UNDER "P" FOR PETERSON - NO FEE
ENVIRONMENTAL REVIEW
COMPLETE Jennifer Evans 11/12/2013 11/12/2013
Comment:
FRONT COUNTER REVIEW
COMPLETE Dawn Milone 11/4/2013 11/4/1013
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE Joe Cicio 12/10/2013
'BOTH TRUSS LAYOUTS MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF
12/10/2013 Comment:
RECORD
Comment:
y/REAR STEPS MUST BE TIED DOWN TO MEET THE WIND SPEED AND EXPOSURE PLANS ARE DESIGNED
12/10/2013
TO * ALSO TO PREVENT MOVEMENT IN FLOOD AREAS * REMOVE PLAN NOTES REGARDING MOVABLE
STAIR RISER ON SHEET 1 AND 3
Comment:
SHEET 5/6 HVAC PLANS AND ELECTRIC PLANS DO NOT MATCH * PLS REVISE ONE OR THE OTHER * ARE
12/10/2013
V1 THESE THE MECHANICAL LAYOUTS YOU ARE USING AS THE LAYOUTS BY NICHOLE ARE NOT LEGIBLE
12/10/2013 Comment:
PLANS STATE 903 S.F / TRUSS PLANS STATE 1003 S.F. / PLS CORRECT ONE OR THE OTHER
Comment:
ENERGY CALC STATES R-38 INSULATION * PLAN SHEET 3/6 STATES R-30 * PLS CORRECT ONE OR THE
12/10/2013
OTHER
Comment:
WHICH THERMA TRU DOOR ARE YOU PROPOSING * THERE ARE SEVERAL LISTED UNDER FL# 5891-R3 [
PLS CLARIFY ON PLAN PRODUCT APPROVAL CHECKLIST ] ENGINEER TO IDENTIFY THE LOUVERED
12/10/2013
SWING DOOR ON THE MECHANICAL CLOSET * PRODUCT APPROVAL MUST INCLUDE A TESTED LOUVER [
PLS CLARIFY ON PLAN PRODUCT APPROVAL CHECKLIST ]
-r
REVIEW COMMENTS
2
Comment: SHEET 1/6 SPECS J.M.METALS FL# 12966.6 AND SHEET 6/6 SPECS FL#6931 WHICH DOES NOT EXIST FOR
12/10/2013 THE ROOF COVERING . ARE THE ROOF PANEL ATTACHMENT SPECIFICATIONS ON SHEET 6/6 COMPLIANT
WITH THE PRODUCT APPROVAL CRITERIA
12/10/2013 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE
ZONING REVIEW COMPLETE Lydia Galbraith 11/5/2013 11/5/2013 11/5/2013
Comment:
S7 -- ! UC I E COUNT,-,
PUBLIC WOQKS DEPAQTMENT
CODE COMPLIANCE D I V I S 10RECI E
2308 VIRGINIA AVENUE
FORT PIERCE, FL. 34952 DEC 17, 2-013
772-462-1553 1
plikNUITP
QEPLY TO COMMENTS DATED Vf00td'8
PEQM I T :m 1310-0359
PETEPSON QES I DENCE
QEV I S I ONZ
QEAQ STEPS
PAGE
I E 3
QEV I S I ONE
UNMATCHED NVAC
PAGE
5
QEV I S I ON=
NO LOUVERED DOOQ
STORAGE
A,E,E, NAVD88
PAGE
2 E 3
QEV I S I ON=
COQQECT NVAC LAYOUT
PAGE
5
QEV I S I ONE
METAL QOOF ATTACHMENT
PAGE
6