HomeMy WebLinkAboutELEVATION CERT U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008
Federal Emergency Management Agency Expiration Date: November 30, 2022
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for(1)community official, (2)insurance agent/company, and(3)building owner.
SECTION A—PROPERTY INFORMATION FOR INSURANCE COMPANY USE
Al. Building Owner's Name Policy Number:
Venetian Administration, LLC
A2. Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Company NAIC Number:
Box No.
4416 N Highway A1A
City State ZIP Code
Fort Pierce Florida 34949
A3. Property Description(Lot and Block Numbers,Tax Parcel Number, Legal Description,etc.)
Lot 2, Block A, Queens Island Preserve, Recorded in PB 60 PG 4, St Lucie County, FL
A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory, etc.) Residential
A5. Latitude/Longitude: Lat.27D 30M 53.43S N Long.80D 18M 28.08S W Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 6
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) 2370.00 sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade 13
c) Total net area of flood openings in A8.b 1666.00 sq in
d) Engineered flood openings? ❑x Yes ❑ No
A9. For a building with an attached garage:
a) Square footage of attached garage 1500.00 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 9
c) Total net area of flood openings in A9.b 1136.00 sq in
d) Engineered flood openings? ❑x Yes ❑ No
SECTION B—FLOOD INSURANCE RATE MAP(FIRM) INFORMATION
B1. NFIP Community Name&Community Number B2. County Name B3. State
St. Lucie County 120285 St. Lucie County Florida
B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s)
Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth)
Revised Date
12111 C0093 K 02-19-2020 02-19-2020 VE 11
B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item 139:
❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS)area or Otherwise Protected Area(OPA)? ❑ Yes ❑x No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 1 of 6
OMB No. 1660-0008
ELEVATION CERTIFICATE Expiration Date: November 30, 2022
IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
4416 N Highway A1A
City State ZIP Code Company NAIC Number
Fort Pierce Florida 34949
SECTION C—BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations—Zones Al—A30,AE,AH,A(with BFE), VE,V1—V30, V(with BFE),AR,AR/A,AR/AE,AR/Al—A30,AR/AH,AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only,enter meters.
Benchmark Utilized: NGS N 633 Elev 5.33 Vertical Datum: NAVD 1988
Indicate elevation datum used for the elevations in items a)through h)below.
❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor(including basement, crawlspace, or enclosure floor) 13.0 ❑x feet ❑ meters
b) Top of the next higher floor 24.1 ❑x feet ❑ meters
c) Bottom of the lowest horizontal structural member(V Zones only) 22.0 ❑ feet ❑ meters
d) Attached garage(top of slab) 9.0 ❑x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building feet 5
(Describe type of equipment and location in Comments) 12. ❑ ❑ meters
f) Lowest adjacent(finished)grade next to building(LAG) 8.9 ❑x feet ❑ meters
g) Highest adjacent(finished)grade next to building(HAG) 12.8 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
structural support 10.1 ❑x feet ❑ meters
SECTION D—SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
1 certify that the information on this Certificate represents my best efforts to interpret the data available. l understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑No ❑Check here if attachments.
Certifier's Name License Number
Robert Kemerson, PSM 6285l� 2
Title
Professional Surveyor&Mapper -y
Place
Company Name
Velcon Engineering&Surveying, LLC Sisal
Address .- Here
1449 Commerce Centre Drive
City State ZIP Code
Port St Lucie Florida 34986
Signature Date Telephone Ext.�f
02-08-2022 (772)879-0477
_L:::
Copy all pages of this Elevation Certificate and all attachments for(1)community official, (2)insurance agent/company, and(3)building owner.
Comments(including type of equipment and location, per C2(e), if applicable)
Please see note attached
Section D-Lattitude&Longitude determined by measure from Geo Referenced Digital Ortho
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 2 of 6
OMB No. 1660-0008
ELEVATION CERTIFICATE Expiration Date: November 30,2022
IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
4416 N Highway A1A
City State ZIP Code Company NAIC Number
Fort Pierce Florida 34949
SECTION E—BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A(WITHOUT BFE)
For Zones AO and A(without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request,
complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only,
enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below
the highest adjacent grade(HAG)and the lowest adjacent grade(LAG).
a) Top of bottom floor(including basement,
crawlspace, or enclosure)is ❑feet ❑meters ❑above or ❑below the HAG.
b) Top of bottom floor(including basement,
crawlspace, or enclosure)is ❑feet ❑meters ❑above or ❑below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 1-2 of Instructions),
the next higher floor(elevation C2.b in
the diagrams)of the building is ❑feet ❑meters ❑above or ❑below the HAG.
E3. Attached garage(top of slab) is ❑feet ❑meters ❑above or ❑below the HAG.
E4. Top of platform of machinery and/or equipment
servicing the building is ❑feet ❑meters ❑above or ❑below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F—PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A(without a FEMA-issued or
community-issued BFE)or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑Check here if attachments.
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 3 of 6
OMB No. 1660-0008
ELEVATION CERTIFICATE Expiration Date: November 30, 2022
IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
4416 N Highway A1A
City State ZIP Code Company NAIC Number
Fort Pierce Florida 34949
SECTION G—COMMUNITY INFORMATION(OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s)and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE)
or Zone AO.
G3. ❑ The following information (Items G4—G10)is provided for community floodplain management purposes.
G4. Permit Number G5. Date Permit Issued G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as-built lowest floor(including basement)
of the building: ❑ feet ❑ meters Datum
G9. BFE or(in Zone AO)depth of flooding at the building site: ❑ feet ❑ meters Datum
G10. Community's design flood elevation: ❑ feet ❑ meters Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments(including type of equipment and location, per C2(e), if applicable)
❑ Check here if attachments.
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 4 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
4416 N Highway A1A
City State ZIP Code Company NAIC Number
Fort Pierce Florida 34949
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View"and"Rear View"; and, if required, "Right Side View"and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
Ci
Y
- _-�•
A- /
MIA C ROI�
_ J
Photo One
Photo One Caption Front View- Date Taken 12-20-2021 Clear Photo One
Photo Two
Photo Two Caption Rear View-Date Taken 12-20-2021 Clear Photo Two
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 5 of 6
BUILDING PHOTOGRAPHS OMB No, 1660-0008
ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2022
IMPORTANT: In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number:
4416 N Highway A1A
City State ZIP Code Company NAIC Number
Fort Pierce Florida 34949
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and 'Rear View'- and, if required, "Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
t
;1
L
l
Photo Three
Photo Three Caption Right Side View-Date Taken 12-20-2021 Clear Photo Three
r r
I
4
1
Photo Four
Photo Four Caption Left Side View-Date taken 12-20-2021 Clear Photo Four
FEMA Form 086-0-33(12/19) Replaces all previous editions. Form Page 6 of 6
4416Highway1 1 Fort Pierce, 34949
P
FrontGarage Vent
1 D. 12/20/2021
saw
Garage Vent Left
�r
t
at
• A .
�c
' 112/20/2021
Section D comments from Elevation Certificate — Lot 2
C2-Benchmark used is a NGS Vertical Control Point "N633" Elev 5.33 NAVD
Permit was applied for and approved under Flood Map panel 12111C0093J - House is in Zone
AO2.
C2(e) - Slab 12.49 - Bottom of AC mounted on brackets is 14.16
C2(h) - Bottom Landing at entry is 12.60; Elevation where walk meets stairs at entry is 10.01
A 8 (a) Lobby/ storage area: 1,265 Square feet. Below pool deck area: 1,105 Square feet. Total
area: 2,370 Square feet.
A 8 (b) Total permanent flood openings 13. 13 flood openings within 1.0 foot above adjacent
grade. 9 Exterior and 4 interior within 1.0 feet of adjacent grade.
A 8 (1) 13 freedom vents Model No. (FFV-1608) = 13 x 250 = 3,250 square feet coverage
A(9) - Smart vent Model No. is (1540-520) = 3 x 200 = 600 square feet coverage.
Freedom vent Model No. is (FFV— 1608)) = 6 x 250 = 1,500 square feet coverage.
Total coverage is 2,100
d
it
•
r .
1
•:.� \ :� -_1 .� t } dab *7 K { 'r � �'�. ��,,,�
e
'� �:< } � , � ,'►.. �, ice!{� �� �; _`� g,�a
( cAw
Garage Rear Pic K&J—Date Taken—12/20/2021
r
c
4
L
f
U
Q
� 1•
w _
SpaceCrawl • ••• 12/20/2021
V
G
Q
Crawl Space Side(Under Pool) Pic G & F—Date Taken 12/20/2021
Crawl Space (Storage Area) Pic B, C, D& E—Date Taken 12/20/2021
SMART VENT
. .. . ...Vents
INSULATED SERIES
This series of vents is ideal for areas requiring °
flood venting protection but no natural
air ventilation.
The flood door contains a 2" insulated core that
has an R-value of 8.34 and the vent frame is lined
with felt weather stripping, helping to keep the
enclosure as insulated from the elements as possible.
IDEAL FOR: :ya
• Garages
RE
• Full height enclosures (e.g. wal outSl
�IAR Z 0 2119 °3
• Conditioned crawlspaces ,
• Storage faCIIIt12S ST. LUCle County, Perm
• Metal buildings '
• Foyers
A
Flood Vent
1540-520
Stacker °F
1540-521 �
x�
Stacker Models are twice as efficient
as a single unit and are a great solution
�9
for large amounts of square footage,
and in situations where there is r .
not enough wall space to fit in
single units. A
4, z= 77
" ;-
._.,.
Wood Wall
' 1540-570
Wood Wall Models are designed to fit
between studs spaced at 16" on center.
Pre-drilled slots in the four corners on
the vent flange make for an
easy installation.
For more information on Rood Protection SrOii,
Smart vent 430 An(Ib:o Drive, Unit, 1 • Pitman, NJ 08071 r �
website: www.sma:tvent.com Tel-, (877) 441-8368 Era'
� r
a
!
'C
,r
rar.
a
STANDARD FINISH POWDER COAT WHITE
,� -- POWDER COATPAINT OPTIONS:
�s
custom colors also ovodoble.
MODEL NUMBER
FLOOD COVERAGE VENT SIZE ROU(�i OPENING
Lt 1inx16$in
To view other sizing options see Multi-fromes
e:
3 t filer'
FLOOD VENT x2
FLOOD VENT x, ��w^�`•�s,-'v<-."y<vr: :.
FLOOD VENT CALCULATION
8'x16"ENGINEERED FLOOD VENTS THAT
E PROVIDE 250 SF OF FLOOD COVERAGE
GARAGE 1520 SF/250 - 6.1 m 7 VENTS )" �-r J � L 4 ii; {r•
9 VENTS PROVIDED fW r 4�i••i:�.v3ys. •':..t .. F
LOBBY/STORAGE AREAS 7265 SF/25D=5.1 =e VENrs r Ay - - ., LOOD VEN7 x2
w 5 VENTS PROVIDED+ I PASS THRU
BELOW POOL DECK AREA 1105 SF/250 - 4.4=5 VENTS ^,••.,..-=-u -••_ Ya l,.i a6h 7 a�k1 SY4 Z�� @t.+•0.s a �,+.
(+1 VENT FOR LOBBY/STORAGE PASS 711RU — 5 VENTS) Ss .�i<N F;..3;:;.. Y�_.- ' •4 %fj.�,:1.`r 1` 3 -
7 VENTS PRavaD FLOOD VENT
THE DESIGN OF THE FLOOD VENT OPENINGS VOL.L
PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD a4-ss
8 FORCES ON IORERIOR WALLS BY ALLOYING FOR THE � c, �rw ry �>.-�,.1',.a,)`•
8 AUTOMATIC ENTRY AND E%R OF FL.00DMATERS AS
SPECIFIED N SECTION 2.7-22 OF ASCE 24. PER FBC ty";T;^;•. n„s �.�1 �
R322.2.2 FOOT NOTE 2.1 _. ,•. ,N.r '. )K I i:}:i`
b• THE BOTTOM OF EACH OPENING SHALL BE NOT MORE
i< THAN I FOOT ABOVE THE HIGHER OF THE FINAL INTERIOR ",>r3� pppp I I I ,•
FLOOR AND THE FINHSLED EXTETOOR GRADE IMMEDIATELY AY4r , S I L ' "•. i a-
BELOW THE OPENING. ? - -- r5; 3},L•r�r•iY4
_ )N �4!
Cnmternn T <:l:
�" `��k�'� ) § �Si� �1 tit i _M y �`•Tii* T. rs.T•
::o.. J
..w- :.�•. Gay• :f5.�-vf°„1`-.s I '.il:.•tAJ.:.�`«� S r�-.�
o � .. � !y} Y_Q r.11•T:cite"'way
FLOOD VENT
(pass thrpuph)xt
as:of F..,i' �T•.-t _ f .i�s.:(tio'ti�'i:r.
.C:;.. .s`.:a,+:--•. -' •�' \ ?:C,��- \+.-s:•. u��;:!�sh'
tn: -t rI rk i`x.,(rSiY k FLOOD VENT x2
:Y L IVERED DOOR
L P`t/cc1�M1 V_.. _ _ Y�'l��'i✓.-Li1 f'L1�.%2 L,.Y(1tijS•L J`}
g j a 1 li i FLOOD VENT x1
"••a {_ FLOOD VENT x2 i r
4 1�� 1 Y U.Y.'•s•�y�I'�Y1 TT..�yl ii
o FLOOD VENT xl
FLOOD VENT x2
DESIGN BY D3K 7HE ORAN'111G5 NE'WE PROP(NTY OF ME • • • « ••«••••.••• «•••••••••«
FAYiREFA YAIEIHER THE PHOlOR MLR YR•OI
DRAWN BY •PMP Structural Concerns • •••.• ••r» . • » 7HLY NE MADE IS EXECM aR Nm.CCPY OA ��•••_,•�� •�, ••�� �•,••�•��
SCALE AS NOTED Exhibit . . . . . » . . . .» . .. .. . or RTT N aR H+ROI(w 6 PHJX(ME dill' ...•..r..........::w..u....o...:.:..�: :'�...:::•.......,
L7Y IIwREli mRHRKI wnei nE FNDNf:IIL ••_..._. . ........... _.
U0U04 IED USE wk BE PROSECUrEO ....__..._._....._....._......_.... V
0.47E 12-27-2021 PUSUW lD THE COPTRIGR V6
MCCEVALUiTiON
IMES Evaluation Report ESR-4332
Reissued March 2020
This report is subject to renewal March 2022.
wwvvJcc-es.orst 1 (800)423-6687 1 (562) 699-0543 A Subsidiary of the lntemational Code Councils
DIVISION:08 00 00- OPENINGS 3.2 Engineered Opening:
Section:08 96 43—Vents 1 Foundation Flood Vents The FV complies with the design principle noted in
REPORT HOLDER: Section 2.7.2.2 and Section 2.7.3 of ASCE/ SEI 24-14
(2018 and 2015 IBC and IRC) [Section 2.6.2.2 of ASCE/
SMART PRODUCT INNOVATIONS,INC. SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a
maximum rate of rise and fall of 5.0 feet per hour
EVALUATION SUBJECT: -(0-423 mm/s). n order o comp y with the engineered
opening requirement of ASCE/ SEI 24, Freedom Flood
FREEDOM FLOOD VENT "AUTOMATIC FOUNDATION Vent' FVs must be installed in accordance with Section
FLOOD VENT:MODEL FFV-1608 4.0 below. See Table 1 for vent size and maximum
allowable area coverage for a single vent.
1.0 EVALUATION SCOPE 4.0 DESIGN AND INSTALLATION
Compliance with the following codes: The model FFV-1608 Freedom Flood Vent'is designed to
be installed into walls or overhead doors of existing or new
■ 2018, 2015, 2012, 2009 and 2006 international Building construction. Installation of the vent must be in accordance
Code®(IBC) with the manufacturers instructions, the applicable code,
■ 2018, 2016, 2012, 2009 and 2006 International and this report. in order to comply with the engineered
Residential Code®(IRC) opening design principle noted in Sections 2.7.2.2 and
2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC)
Properties evaluated: [Section 2.6.2.2 of ASCE/ SEI 24-05 (2012, 2009, 2005
IBC and IRC)],the Freedom Flood Vent- must be installed
■ Physical operation as follows:
■ Water flow ■ With a minimum of two openings on different sides of
each enclosed area.
■ Weathering
■ With a minimum of one FV for every 250 square feet
2.0 USES (23.2 mz)of enclose a
The model FFV-1608 Freedom Flood Vent' is used to ■ Below the base flood elevation.
equalize hydrostatic pressure on walls of enclosures ■ With the bottom of the vent located a maximum of
subject to rising or falling floodwaters. With the cover 12 inches (305.4 mm) above the higher of the final
removed, the model FFV-1608 also provides natural air interior grade or floor and the finished exterior grade
ventilation. immediately under each opening.
3.0 DESCRIPTION 6.0 CONDITIONS OF USE
3.1 General: The Freedom Flood Vent- described in this report
The model FFV-1608 Freedom Flood Vent' is an complies with, or is a suitable alternative to what is
engineered mechanically operated in-wall flood vent (FV) specified in,those codes listed in Section 1.0 of this report,
that automatically allows floodwater to enter an enclosed subject to the following conditions:
area and exit. The FV is comprised of a polycarbonate 6.1 The model FFV-1608 Freedom Flood Vent' unit must
frame with mounting flange and a polycarbonate be installed in accordance with this report, the
horizontally pivoting door. When subjected to rising water, applicable code and the manufacturer's published
the model FFV-1608 Freedom Flood Vent' door is Installation instructions. In the event of a conflict, the
activated and pivots to allow water and debris to flow in instructions in this report shall govern.
either direction to equalize hydrostatic pressure from one 6.2 The model FFV-1608 Freedom Flood Vent- unit must
side of the enclosure to the other. The FV features a not be used in place of"breakaway walls" in coastal
removable polycarbonate cover. The FV door will activate high hazard areas, but are permitted for use in
and pivot when subjected to rising water with or without the conjunction with breakaway walls in other areas.
polycarbonate cover installed.
ICC-ES Evaluation Reports are not to be construed as-representing aesthetics or any other attributes not speclflcally addressed,nor are they to be construed
as an endorsement ojthe subject ojthe report or recommendation for its use.There is no warranty by ICC Evaluation Service,L.LC;express or implied,as 1,1*
to arty finding or other matter in this report,or as to any product covered by the report.
wuionnc ,,...
Copyright 0 2020 ICC Evaluation Service,LLC. All tights reserved. Page 1 of 4
FSR-4332 I Most Vlhdely Accepted and Trusted Page 2 of 4
5.3 Use of the Freedom Flood Vent as under-floor space 7.2 The report holder's contact information is the
ventilation is outside the scope of this report. following:
6.0 EVIDENCE SUBMITTED SMART PRODUCT INNOVATIONS, INC.
430 ANDBRO DRIVE,UNIT 1
Data in accordance with the ICC-ES Acceptance Criteria PITMAN,NEW JERSEY 08071
for Mechanically Operated Flood Vents (AC364), dated (800)507-1627
August 2015(editorially revised October 2017). www.freedomfloodvent.com
7.0 IDENTIFICATION info(&freedomfloodvent.com
7.1 The Freedom Flood Vent' model recognized in this
report must be identified by a label bearing the
manufacturer's name (Smart Product innovations,
Inc.)and the evaluation report number(ESR-4332.).
TABLE 1—FREEDOM FLOOD VENTTm
MODEL NAME MODEL NUMBER MODEL SIZE COVERAGE(sq,R,)
Freedom Flood Vent"m FFV-1608 153/4"X 81/16" 250
For SI: 1 inch=25.4 mm
Y 1
FIGURE 1—MODEL FFV-1608 FREEDOM FLOOD VENT^":SHOWN WITH COVER REMOVED
FIGURE 2—MODEL FFV-1608 FREEDOM FLOOD VENTTm,SHOWN WITH FLOOD DOOR PIVOTED OPEN
LS
ICC-ES Evaluation Report ESR-4332 CBC and CRC Supplement
Reissued March 2020
This report is subject to renewal March 2022.
www.icc-es.orn ( (800)423.6687 1 (562) 699-0643 A Subsidiary of the International Code Council®
DIVISION:08 00 00—OPENINGS
Section:08 96 43—Vents I Foundation Flood Vents
REPORT HOLDER:
SMART PRODUCT INNOVATIONS,INC.
EVALUATION SUBJECT:
FREEDOM FLOOD VENTTM AUTOMATIC FOUNDATION FLOOD VENT: MODEL FFV-1608
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that the Freedom Flood Vent- Automatic Foundation Flood
Vent: Model FFV-1608, recognized In ICC-ES master evaluation report ESR-4332, has also been evaluated for compliance
with codes noted below.
Applicable code edition(s):
■ 2016 California Building Code(CBC)
■ 2016 California Residential Code(CRC)
2.0 CONCLUSIONS
2.1 CBC:
The Freedom Flood Vent'Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the
master evaluation report ESR-4332, complies with CBC Chapters 12, 16 and 16A, provided the design and installation are in
accordance with the 2015 International Building Code®(2015 IBC) provisions noted in the master report and the additional
requirements of 12, 16,and 16A,as applicable.
The product recognized in this supplement has not been evaluated under CBC Chapter 7A for use in the exterior design
and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any
Wildland-Urban Interface Fire Area.
2.2 CRC:
The Freedom Flood Vent-Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the
master evaluation report ESR-4332, complies with the 2016 CRC, provided the design and installation are in accordance
with the 2015 Intemational Residential Code®(2015 IRC)provisions noted in the master report.
The product recognized in this supplement has not been evaluated under 2016 CRG Chapter R337, for use in the exterior
design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any
Wildland-Urban Interface Fire Area.
The product recognized in this supplement has not been evaluated for compliance with the International Wildland—Urban
Interface Cade®.
This supplement expires concurrently with the evaluation report, reissued March 2020.
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as
to anyfinding or other matter in this report,or as to any product covered by the report.
Copyright 0 2020 ICC Evaluation Service,LLC. All rights reserved. Page 3 of 4
ESEVALUATION
ICC-ES Evaluation Report ESR-4332 FBC Supplement
Reissued March 2020
This report is subject to renewal March 2022.
www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the Intemational Code Council®
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
SMART PRODUCT INNOVATIONS, INC.
EVALUATION SUBJECT:
FREEDOM FLOOD VENTrm AUTOMATIC FOUNDATION FLOOD VENT: MODEL FFV-1608
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that Freedom Flood Vent~Automatic Foundation Flood Vent:
Model FFV-1608, recognized in ICC-ES master evaluation report ESR-4332, has also been evaluated for compliance with
the codes noted below.
Applicable code editions:
■ 2017 Florida Building Code—Building
■ 2017 Florida Building Code—Residential
2.0 CONCLUSIONS
The Freedom Flood VentT11 Automatic Foundation Flood Vent: Model FFV-1608,described in Sections 2.0 through 7.0 of the
master evaluation report ESR-4332, complies with the Florida Building Code—Building and the Florida Building Code—
Residential, provided the design and installation are in accordance with the International Building Codes (IBC) provisions
noted in the master report.
Use of the Freedom Flood Vent- Automatic Foundation Flood Vent: Model FFV-1608 has also been found to be in
compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building
Code—Residential.
For products falling under Florida Rule 9N-3, verification that the report holders quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity(or the code official, when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the evaluation report,reissued March 2020.
ICC-ESEvaluation Reports ora not lobe construed as representing aesthetics or any other attributer not specifically addressed,nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,ezprass or implied,as l t
to anyfinding or other matter in this report,or as to anyproduct covered by the report. woitrou°
Copyright 0 2020 ICC Evaluation Service,LLC. All nghts reserved. Page 4 of 4