Loading...
HomeMy WebLinkAbout2119579-2 THOMPSON 7909 INDIAN RIVER DR FT PIERCE FL (E-FILE FINAL)DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: D 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = D FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 51 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 40 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 14 PSF VERTICAL PRESSURES ON SOLID SURFACES = 42 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4' CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 'X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4' X 2-3/4" TAPCONS OR EQUAL AT 24' O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 DETAILS S/04 DETAILS PROPOSED MANSARD SCREEN ENCLOSURE SEE FOUNDATION DESIGN SHEET-01 c > a c Digitally signed dui o c °c m- a� GUNO'/ o.L�a L o2; by Craig E yU c� `.�;........ _ No.60102 Gunderson c� c �� 'O O O O = n � 4)LLj O C :3N %�•°•.• STATE OF :•�\ Date: 2022.01.28 Em� o w S/ONA.. `o` oaC 2aa�co�_�2 15:54:23-0500 (n C C C�� N N U L 01 7 F0 0 0 0 0 I— N 0 7 U U :E N a U� J O J V Nz_ 0. LU z f_n V w 0 J LL N C7 co O U p U OM LL LO L � N co c O� J Q) U � o 0- N w o co w U U U Z Z00 � � N J O) Q > O J Z ZO Q W LU dZ 0-10 O zw a Orn0- CD w �I-L~L z 0 0 a DESIGN DATE: 07/15/2021 REVISION 1: 01/27/2022 REVISION 2: DATE SHEET: O II� DRAWN BY: TCP SCALE: NTS RESIDENCE ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. # 10 SCREW 6" FROM ENDS & 12" CENTER TO CENETER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X3"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 7. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. 8. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 2'-0" 8'-7 8 7'-114 7'-114 7'-11 4 2--0-- 1X2 \ 0 0 x x \ N N co DO 2X2 2 \\\ � Ln x O r, n n \ Vl N N ry N \\ N 1X2 + 2X2 \\ 1 IL1L RESIDENCE 34'-5" HOST 24" O/H STRUC. GUTTER J - ----------------- ------ on rn Ln II ^ x _ NIA II II II 2X3 TYP. 2X3 TYP. Iii - -1 iII III Iw I� I I 2X3 TYP. 2X3 TYP. I� cc L on DODO w coon o o I� M O O m O I O N II N r' N ^ N N `yj N I O 2X3 TYP. 2X3 TYP. j IN IN 0 Ix -1 II � II I II 2X3 TYP. 2X3 TYP. III 11 II II �Q• �Ia II I 00ILn TN1 57'-7" 7 T� -T 4'-0" MAX. I I I I I 1X2 + 2X2 / / /m co DO 2 co 2 co co 2 DO 2 2 X o N N /// / x N x x x X x x x c-I N N N N 2X2 TYP. "' N // N Q Q / N N / x x N N 1X2 TYP. / 7'-11— 7'-11— 7'-11— 7'-11— 7'-11— 7'-11— 7'-11— 2' 4 4 4 4 4 4 4 0 N 1X2 x N N + N N Ln � 1X2 1 (714 1X2 N N N _� x X l N x 1X2 N �9'-0"-----� c co Digitally signed w _ ° a� : AGE Ns°FRs°'' �� a m m a)VQ?• F'•a�2=s b Craig E U a) ai yU c p > -FDa) a) _ tr:' No.601 02 GUnderSGunderson>a� c c�ccEf -0 o a� N _ _ _ z� - •� Date: N p a� ui � u r-EID 3 STATE OF 5- N. c �� 3 6 OP.•`�: ORI 2022.01.28 S��NAI\E\\ Em(00Z--�cc � -0 a) co m 2 i i 15:54:29 -05 00 U CL)N USN J 00 o J (71) �.J Z z Q ELU O U p U w J 0 W � cy) LLLo. V ~W co C w Q -i U Q Q�� F— C) O (0 � N J LL O LO O Z H U W �0�/ U Z Z N C00 J O) Q > O -j ILL cf) ZO D � Q W LU dZ� O O S �zw a Orn� CD w ��L~L Z O U d DESIGN DATE: 07/15/2021 REVISION 1: 01/27/2022 REVISION 2: DATE SHEET: 02 DRAWN BY: TCP SCALE: NTS 1"x2" FASTEN TO COL. (INTERNAL) w/(2) #IOxl-1/2"SMS, FASTEN TO EAVE RAILS ABOVE w/#10 1-1 /2" SMS 24" O.C. AND 6" WITHIN COL. TABLE "D" BEAM QTY/ SIZE EACH SIDE 2x3 (4)/#12 2x4 (5)/ #12 2 x 5 IS)/ #12 2x6 (6)/#12 2x7 (7)/#12 2x8 (8)/#14 2x9 (9)/#14 2 x 10 (9)/ #14 MAINTAIN MIN, OF 5/8" SEPERATION FROM EDGE OF BEAM SMS O.C. ° BEAM PER PLAN ° ° ° (SLOPED OR FLAT) o o ° BEAM PER PLAN (2) #1Ox NOTCHED TO RECEIVE INTO BEAT COLUMN WITHIN BEAM SMS, (EACH SIDE) INSTALL BRA QTY/ SIZE PER TABLE "D" TO CORI• NOTCH PROFILE MAY VARY TO PERMIT CORRECT # SMS ° COLUMN PER PLAN DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS MINIMUM NUMBER OF TAPCONS INTO CONCRETE & # 12 X 3/4' S.M.S. INTO UPRIGHT / EACH SIDE OF BEAM THROUGH SECONDARY 2" X 2" X 0.125" ANGLES (SEE BELOW) 2X4 S.M.B. (1) 1/4" X 2-1/4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. 2X5 S.M.B. (1) 1/4" X 2-1/4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. 2X6 S.M.B. (2) 1/4" X 2-1/4" S.S. TAPCON & (3) # 12 X 3/4" S.M.S. 2X7 S.M.B. (2) 1/4" X 2-1/4" S.S. TAPCON & (4) # 12 X 3/4" S.M.S. 2X8 S.M.B. (3) 1/4" X 2-1/4" S.S. TAPCON & (5) # 12 X 3/4" S.M.S. 2X9 S.M.B. (4) 1/4" X 2-1/4" S.S. TAPCON & (6) # 12 X 3/4" S.M.S. 2X 10 S.M.B. (5) 1 /4" X 2-1 /4" S.S. TAPCON & (7) # 12 X 3/4" S.M.S. 1 /8.'x2"x2'k ANGLE 5032 H-32 ANGLE (2) - #12 SMS INTO COLUMN- 1/4" MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 2-1/4" MIN. CONC. ° ANCHOR EMBEDMENT ` SECONDARY ANGLE o 3000 PSI CONC. SLAB/ FTG. 6x6-10x10 WWM OR FIBERMESH 1/4" MASONRY ANCHOR AT EACH ANGLE SELF -MATING OR SNAP SECTION TYP. M(2" O.B. BASE PLATE-TYP. 0 0 1-1/4" MIN. CONC. ANCHOR EMBEDMENT d 2" MIN. INCREASE DISTANCE WHEN GREATER THAN 2x4 p UPRIGHT IS USED SIDE VIEW NOTE WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-1/4" (MIN.) �(2) - #12 SMS 1 /4" TAPCON XL (RED HEAD MFG. OR EQUAL) 2 Q I x2 BASE 2 Q SLAB (BEYOND) 3000 PSI CONC. SLAB/ FTG. 6x6-1Ox10 WWM FRONT VIEW OR FIBERMESH DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS (2) # 1 Ox3"SMS INTO SCREW BOSSES FOR EDGE MEMBER EDGE MEMBER ° 0 OR PURLIN ° ° I :E EDGE MEMBER OR PURLIN 0.0625" 6063-T6 FLAT PLATE w/(8) # 1 Ox.75" SMS, MIN..5" EDGE DISTANCE, PLATE MAY BE FASTENED INTERNALLY TO BRACE DETAIL "D" - ROOF BRACING CONNECTION SCALE: NTS FASTEN TOP OF HEADER TO INTERSECTING 2"x2" MEMBER w/(2) #10 SMS w/1" PENETRATION INTO SCREW BOSS OF 2"x2" MEMBER - TYP. BOTH SIDES 2"x2" DOOR JAMB FASTEN HEADER w/(2) #IOx3" INTO SCREW BOSS OF HEADER ALTERNATE HEADER CONNECTION WHEN Z-BAR IS USED - FASTEN Z-BAR TO COL/HEADER AT EACH CORNER AND 18" O/C ALTERNATE BASE PLATE CONNECTION ATTACH 2"x2" TO BASE PLATE (INTERNAL) w/(2) #10x2"SMS ATTACH BASE PLATE TO 2"x2" w/(2) #10x3" SMS INTO SCREW BOSS OF BASE PLATE 1"x2" BASE PLATE ANCHORED TO CONC w/ 1 /4" MASONRY ° ANCHOR 6" MAX EACH SIDE e o . p OF POST AND 24" O.C. MAX 1-1 /4" CONC. EMBEDMENT TYP. 1/4" TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF COLUMN 1-1 /4" PENETRATION INTO UNDERLYING FOOTING DETAIL "F" - DOOR JAMB & HEADER CONNECTION SCALE: NTS ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.050" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS 1 x2: 1"x2"x0.044" 1 x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 SNAP: 2" x 2" x 0.045" 2 x 3 SNAP: 2" x 3" x 0.050" 2 x 4 SNAP: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SM B: 2" x 4" x 0.046" x 0. 100" 2 x 5 SMB: 2" x 5" x 0.050" x 0. 116" 2 x 6 SM B: 2" x 6" x 0.050" x 0. 120" 2 x 7 SM B: 2" x 7" x 0.055" x 0. 120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.224" 2 x 9 SMB: 2" x 9" x 0.072" x 0.224" 2 x 9(H) SMB: 2" x 9" x 0.082" x 0.306" 2x 10SMB: 2"x 10"x0.092"x0.374' ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNELw/(4) #1Ox.75" INTO GIRT OR PURLIN & (2) #14x.75" INTO BEAM OR UPRIGHT 0.062 ANGLE CLIPS MAYBE USED UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW c co T Digitally signed w� .Up 5�0 L 61UNNpFF ''Q.S by Craig Edc 0 — 0 0 yUCO c-o > a)cN ; No.60102 Gunderson o>,-a �10 c m E row `a ° Sa = - - -Date: m LLI U c E ; �•••. STATE OF c ,O)z 3 ,,,FS °.� ORIOG\. 2022.01.28 c: a j5 aa) c E 0 ��acmo 15:54:33-05r00 (/1 C C C) N N U 1-Air 7 U Uw N (4) # 1 Ox 1-1 /2" SMS INTO SCREW BOSSES PURLIN MEMBER JO J F— co zz Q E O � p U w J 0 co W � LL • � W (D~ coC LZ Q � Q Q�� U O J L o a N 00 r` 0 M *k LU U U N ti LO rn N DETAIL "C'' - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS U Z 2"x2"x.063" - DIM. TO MATCH PURLIN SIZE RECEIVING CHANNEL (2) #12 SMS INTERNAL TO EAVE RAIL Z (3) #12 EACH SIDE INTO PURLIN 0 N Z- ° Q LLL.I 00 OD 2 P�RUN > Co o EAVE RAIL - SEE PLAN ° O J EXTRUSION z Ix2OPEN BACK ii p Q LLI EXTRUSION UPRIGHT w (n E C) of 0- Z 0-1 (2) #10x2"SMSTHRU 1x21NTO Q O _ p — LLI EAVE RAIL EACH SIDE OF COLUMN U Q O 00 CD Qf 2 w H � LL z O U d DESIGN DATE: 07/15/2021 DETAIL "G" - SLOPED PURLIN REVISION 1: 01/27/2022 CONNECTION SCALE: NTS REVISION 2: DATE SHEET: DRAWN BY: TCP O SCALE: NTS GIRT FASTENED INTERNALLY AT EACH END 1"x5"x2" WIDTH EXTRUDED GUTTER BRACKET w/ #IOx1.5" EACH SCREW GROOVE. FASTEN (THICKNESS OF LEG @ WOOD SCREW SHALL BE TO BEAM w/ 2"x2""x1/8" ANGLE (2) #12 SMS 0.125" MIN., LONG LEG SHALL BE 0.072" MIN.) INTO BEAM & (2) #IOx1.5 THRU ANGLE INTO @ EACH BEAM w/(2) #I2x3/4" SMS @ 1"SPACING GUTTER WHERE NO GIRT IS PRESENT, ATTACH INTO GUTTER LIP. FOR BEAMS ABOVE 2x8 INSTALL ANGLE DIRECTLY TO GUTTER GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION. .050" GUTTER STIFFNER 2"x2"xl /8" ANGLE FASTEN TO FASCIA w(2) w/(2) #12 SMS #12x2" WOOD SCREW EACH LEG FASTEN TO GUTTER w(2) #12SMS EXISTING HOST STRUCTURE BR CEE o (DESIGNED BY OTHERS) WHEN BEAM & PURLIN ° HIT ON CORNER - BEAM o FASTEN OUTSIDE OF (2) #12 SMS (2) #14 WOOD SCREWS @ 1" BEAM & PURLIN w/ 1/8"x2"x2" ANGLE o SPACING @ EACH GUTTER BRACKET w w & (4) # 12 SMS EACH LEG 0 & (1) @ 19' O.C. MAX. O 0 0 MIN. EMBEDMENT SHALL BE 2" < (9) # 14x3/4" St` 0— CLOSE BOTTOM OF o 0 1 /8" PLATE ON 45° ANGLE BEAM WHEN TRIMMED FOR BEAM OVER 2x5 044 RECEIVING CHANNEL, OR 1/8"x2"x2" ANGLE w/(4) #12 SMS INTO EACH .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER FASTEN w/(2) #12 SMS INTERNALLY w/(2) #12 SMS FASTEN INSIDE CORNER INTERSECTING MEMBER EACH SIDE OF BEAM ALTERNATELY 2x2x1/8" ANGLE BELOW GIRT, (2) #14 SMS INTO (BEAM BEAM & (2) #12 SMS INTO STRUCTURAL GUTTER 8 x22"x2" ANGLE w/(2) #12SMS INTO EA. SIDE VIEW (BEAM & URLIN)R OPTIONAL GIRT #10SMS WITHIN6" DETAIL "M" BEAM & PURLIN TO GUTTER PERIMETER FRAMING & @ 24" O.C. MAX. FASTEN GUTTER TO CONNECTION SCALE: NTS WOOD SCREW 18" O.C. 2x2x1/8"/ EA. SIDE OF w/(2) #1 EACH LEG EAC (2) #12SMS (2) # 14x2" WOOD SCREW @ I" SPACING FASCIA (2"x6" MIN. EXISTING) STRUCTURAL GUTTER TOP VIEW DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: NTS h— F ° F o o o 0 0 0 F �'\ ° o� o ° o o F o 0 o o Lo o o F F o 3/16"-5052-H32 GUSSET o� ° F INTERNAL OR EXTERNAL 2 x 10 SMB ILLUSTRATED F NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2"SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 TABLE B-1 BEAM SIZE COL. TO BEAM QTY SMS/ SIDE OF COL. BEAM TO BEAM QTY SMS/ EA. FACE/SIDE 2x4 (5) #12 (9) #12 2 x 5 (5) #12 (9) #12 2 x 6 (7) #12 (9) #12 2x7 (10) #12 (10) #12 2x8 (12) #12 (14) #12 2x9 (14) #14 (14) #14 2x 10 (16) #14 (15) #14 DETAIL "K" GUSSET CONNECTION SCALE: NTS 2"x2"xl /8" ANGLE w/(2) #12SMS EA. LEG 1/8"x2"x4" STI 121 #12 SMS INTO BE, ..., (2) #12 SMS INTO GUTTER 2"x2"xl/8" ANGLE 1 2) # 12 SMS EA. LEG SMB SIDE VIEW —GIRT (2) GUTTER BRACES EACH w/(2) # 12 SMS FASCIA INTO GUTTER & (2) #14 WOOD SCREWS INTO FASCIA GUTTER BRACE (2) # 12 SMS 0 �m 1 /8"x2"x4" STRAP GIRT (2) #12 SMS INTO BEAM STRUCTURAL GUTTER (2) #12 SMS INTO GUTTER TOP VIEW DETAIL 1" CORNER CONNECTION SCALE: NTS c co Digitally signed c LLI o 5 c a a) a)E• o \\GU by Craig E 2 0 M ��PG��CENSFRSQ2, �� _ _-0' ` = ': Na.80102 Gunderson c� c c E °. �; Date: w U) O c ui 'O E (D STATE OF .• Q •. A, ��ss o a a 3 p <OR..... . 2022.01.28 � a a) 2.0 2 15:54:3 7 -05 00 g C C c N N N U L 7 'Vl O O N H A(D 7 U Uw N DETAIL 1-2" CABLE CONNECTION AT CORNER SCALE: NTS EBOLT FOR 4BLE TENSION 1/8" STAINLESS STEEL BRAIDED CABLE 1 /8" STAINLESS STEEL BRAIDED CABLE 40°MIN. 60° MAX. d a o o 3000 PSI CONC. 3" A.S.T.M. A-36 STEEL CLIP 6x6-10x10 WITH (2) 3/8'k3"SLEEVEANCHORS WWM OR FIBERMESH FOR PAVERS (2) 1/4"x6"TAPCONS THRU PAVERS INTO FOOTING 40° MIN. 60° MAX. 3000 PSI CONC. 6x6-1Ox10 WWM OR FIBERMESH 40° MIN. 60° MAX. 1 /8" STAINLESS STEEL BRAIDED CABLE 3/8" DIA x 3" EMBED CONC. SCREW ANCHOR (TAPCON OR EQUAL) 1 /8" STAINLESS STEEL BRAIDED CABLE o O 1 3000 PSI CONC. 6x6-1 Ox10 1.5x5.5" ALUM. STRAP WWM OR FIBERMESH w/(2) 3/8" DIA. x 3" MASONRY ANCHOR (TAPCON OR EQUAL) DETAIL 1-1" CABLE CONNECTION AT FOUNDATION SCALE: NTS USN J O LO 00 o J M co M z Z Z Q E O LU U U p U w J 0 � W Q I-Ln.E- ~_ Uj V co C W Q O F_ U N J lLL 0 a L0 0 z 0 W 0 I U z z N 000 J O) Q i M O J z OQW ZLU 0-10 d O zw a Orn0- CD w ��LLLL z O 0 a DESIGN DATE: 07/15/2021 REVISION 1: 01/27/2022 REVISION 2: DATE SHEET: 04 DRAWN BY: TCP SCALE: NTS