HomeMy WebLinkAboutBuilding PlanROOF EC)GE R803.2.3.1 SHEATHING FASTENINGS. WOOD STRUCTURAL PALL SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH 8D RING - SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE FRAMING. ZONE I RING -SHANK NAILS SHALL HAVE THE FOLLOWING l MINIMUM DIMENSIONS 1. 0.113 INCH NOMINAL SHANK DIAMETER. 2. RING DIAMETER OF 0,012 OVER SHANK DIAMETER. 3.16 TO 20 RINGS PER INCH, 4. 0.280 INCH FULL ROUND HEAD DIAMETER. 5, 2 INCH NAIL LENGTH. ROOF SHEATHING NAILING ZZO EIS PRE -EN AS PER F,B.C.2514.3,5 METAL AND WIRE LATH SHALL BE ATTACHED TO VERTICAL WOOD SUPPORTS WITH THE EQUIVALENT OF 4D GALVANIZED OR BLUE COMMON NAILS DRIVEN TO A PENETRATION OF AT LEAST 3/4 INCH (19 MM) AND BENT OVER TO ENGAGE NOT LESS THAN T1 IREE STRANDS OF LATH. METAL AND WIRE LATH SHALL BE ATTACHED TO CEILING JOISTS OR OTHER HORIZONTAL WOOD SUPPORTS WITH THE EQUIVALENT OF NO. II -GAUGE`, BARBED, GALVANIZED OR BLUED NAILS 1-1/2 INCHES (38 MM) LONG HAVING A HEAD NOT LESS THAN 3/8 INCH (9.5 MM)N DIAMETER. SOFFIT VENTS TO BE 6"X24" AT 8' O.C, MAX. EXTER 1 OR CEILING/SOFFIT DETAIL N.T.S. GENERAL NOTES 1, CONSTRUCTOOr l SHALL FOLLOW-FLORIDA BUILDING CODE" AS ADOPTED BY THE AREA IN WHICH THE BUILDING IS TO BE CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS. 2. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC, SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC, 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES, STUCTURAL NOTES: I, DESIGN LOADS IN ACCORDANCE WITH FBC CHAP, 16 2. SOIL BEARING CAPACITY: 2500 PSF 3. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. 4. SLAB/FOOTINGS TO BE CONCRETE WITH MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS, SEE PLANS FOR SIZE AND STEEL REQUIREMENTS, 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS, FOOTINGS: 3" BEAMS: 1-1/2" SUSPENDED SLABS: I" 6, LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS, GRADE 60 STEEL MINIMUM IN FOOTINGS AND SLAB. GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 9, UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE. IO.BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL. STUDS IN A NUMBER EQUAL TO THE NUMBER OF PLIES OF: THE BEARING MEMBER WHEN THE BEARING MEMBER IS 2 OR MORE PLIES UNLESS NOTED. II. ROOF SHEATHING TO BE NAILED WITH IOD GALV. OR 8D RING SHANK NAILS OR EQUAL 4" O.C. EDGES AND 6" O.C. IN FIELD 12.FRAME TO MASONRY SEGMENT CONNECTIONS, PT 2 X 4 MINIMUM TO MASONRY WITH 1/2" DIAMETER 7" EMBEDMENT WEDGE BOLTS I AT TOP AND BOTTOM 36" OC THEREAFTER. 13.ALL SOILS TO BE COMPACTED TO MIN. 95% DENSITY 14.CORNE12 BARS ARE REQUIRED AT ALL OUTSIDE CORNERS 15.FOOTINGS SHALL BE A MIN. OF 16" IN WIDTH OR AS INDICATED ON DRAWINGS 16.ROOF DL Z LL , 55 P.S.F. 17.UPLIFT FORCES AS PER ENGINEERS NOTES AND SCHEDULES 18.FLOOR LL - NA 19.ALL PRE -CAST LINTELS TO HAVE MIN.6" BEARING 20.ALL STANDARD LUMBER SHALL BE SPF WITH A MINIMUM FB OF 1000 PSI OR NO,2 SOUTHERN PINE, UNLESS NOTED OTHERWISE. PENETRATIONS THROUGH ANY SEPARATION SHALL BE PROTECTED BY FILLING THE OPENING AROUND THE PENETRATING ITEM WITH APPROVED MATERIAL TO RESIST THE FREE PASSA zE OF FLAME AND PRODUCTS OF COMBUSTION, NOTES: 1. HOUSE IS IN A NEGLIGIBLE WEATHER AREA 2. HOUSE IS IN A VERY HEAVY TERMITE AREA 3. FLAME SPREAD FOR WALLS AND CEILING FINISHES SHALL BE LESS THAN 200 4, FLAME SPREAD FOR INSULATION SHALL BE LESS THAN 25 5. SMOKE DEVELOPED INDEX SHALL BE LESS THE 450 FOR WALL FINISHES, CEILING FINISH AND INSULATION 6. GYPSUM BOARD SHALL CONFORM TO FBC R702.3 STANDARDS 7, TILE IN SHOWERS MUST BE BACKED BY "DURA ROCK" CONCRETE BOARD OR EQUAL ST. LUCIE QQLkEr5UILDING DES TNIE\7 PRODUCT APPROVAL CHECKLIST PERMIT TYPE: S.F.R. PERMIT NUMBER: OWNERS NAME_ BETH EAMES DESIGN PROFESSIONAL NAME A/E JOHN H. CRESWELL, P.E. _ JOB SITE LOCA"ION; 992 NETTLES BLVD, RULE 9 B-72 REQUIRES THE FOLLOWING INFORMATION AS PROMULGATED BY THE FLORIDA BUILDING COMMISION, IN THE EVENT THAT INFORMATION REQUIRED FOR PRODUCT APPROVAL HAS BEEN INCORPORATED IN TO TE PLANS, SPECIFICATIONS OR GENERAL NOTES, SIMPLY INDICATE PAGE NUMBERS ON THE AFFIDAVIT. PRODUCT MODEL NUMBER A.CTURER EVALLA'iION AGENCY NOA NUMBER EXPIRATION DATE WINDOWS -SINGLE HUNG SERIES SH-7700 --4-NSON IMPACT GLASS MIAMI-DADE 12-0127.16 12/27/2016 EXIT DOOR, SOLID CORE EXTERIOR HINGED DOOR 1A-TRU FLORIDA BUILDING CODE FL 5891-R3 NA ROOFING MATERIAL 5V-CRIMP J.Pw1 \1ETALS FLORIDA BUILDING CODE FL 12966.6 NA IN ACCORDANCE WITH THE FLORIDA ARCHITECTS AND ENGINEERS PRC..C" APPROVAL SYSTEM THIS AFFIDAVIT CERTIFIES THAT I HAVE PERFORMED THE BUILDING ENVELOPE EVALUATION AS REQUIRED BY THE FLO21DA BUILDING CODE. =# 40940, COA# 27002 ARCHITECT/ENIGINEERS'S SIGNATURE =L.. CERT./REG. NUMBER R702.4.1 GENERAL.. CERAMIC TILE SURFACES SHALL BE INSTALLED IN ACCORDANCE WITH ANSI A108.1, A108A, A108.5, A108.6, A108.11, AI18.1, AI18.3, AI36.1 AND A1371 R702.4,2 CEMENT,FIBER-CEMENT AND GLASS MAT GYPSUM BACKERS. CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325 OR C: 1178 AND INSTALLED WITH 1-1/4, WAFER HEAD, RUST RESISTANT DRILL OR SHARP POINT SCREWS AT 8" O.C. IN FIELD AND 4" O.C. AT EDGES, BACKING FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS, ON MIN. 2" X 4" WOOD FRAMING. SEE TYPICAL WALL SECTION FOR FOOTING DETAILS EMBED =5 DOWEL 7" INTO 007'\G W/EPDXY MISSED DOWEL DETAIL (9) IOD X 1-1/2" STRAP TO TRUSS SIMPSON MTS 16 ATTACHED TO BLOCK WA3)- 3/16" X 1-3/4" TAPCONS TYPICAL CONC.BLK EXTERIOR WALL MISSING TRUSS STRAP DETAIL ice- � �• �.� �'. Ay +•�.. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THIS STRUCTURE HAS BEEN DESIGNED AND REVIEWED FOR COMPLIANCE OF FSC 1606.1.4 FOR ONE OF THE FOLLOWING: INTERNAL WIND PRESSURE WIND13ORNE DEBRIS PROTECTION IMPACT RESISTANCE GLAZING Imo) . Lu r-of-7 Ty Numpm nMSTO REVIFWL1) F(; R MP REVIEWED Y DATE ,. P%AIVS AND PERMIT MUST BE KEPT ON JOB OR NO rNSPECTION WILL BE MADE, ` ST. LUCIE COUNTY BUILDING DEPARTMENT CODE COMPLIANCE DIVISION DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE THIS CERTIFICATION MUST BE COMPLETED BY THE PROJECT DESIGNER, ARCHITECT OR ENGINEER. THIS CERTIFICATION MUST BE SUBMITLAD IN DUPLICATE WITH ALL. APPLICATIOAS FOR BUILDING PERMITS INVOLVING THE CONSTRUCTION OF NEW RESIDENCE (SINGLE OR MULLTI-FAMILY), RESIDENTIAL ADDITION, ANY ACCESSORY STRUCTURE REQUIRING A BUILDIUG PERMIT AND ANY NONRESIDENTIAL STRUCTURE. THIS CERTIFICATION SHALL NOT APPLY TO LNTERIOR NENOVATIONS (PROVIDED THAT NO EXTERIOR STRUCTURAL WALLS. COLUMNS OR OTHER COMPON=TS ARE BEING AFFECTED) AND CERTAIN OTHER MINOR BUILDING PERMITS FOR FURTHER ASSISTANCE PLEASE CONTACT THE BUILDING INSPECTION OFFICE OWNER BETH EAMES PERMIT NUMBER ADDRESS 992 NETTLES BLVD, OCCUPANCY TYPE SFR CONSTRUCTION TYPE CBS CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY, I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOAD AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED (PLEASE CHECK OR COMPLETE THE APPROPRIATE BOX) 1. FLORIDA BUILDING CODE 2010 EDITION AND ASCE 7-10 2. BUILDING DESIGN IS: ENCLOSED: YES PARTIALLY ENCLOSED, OPEN BUILDING: 3 MEAN ROOF HEIGHT: <LESS THAN 15' ROOF PITCH: 4/12 INTERNAL PRESSURE COEFICIENT. +/- 0.18 4. WIDTH OF END ZONES < 4.5' WIND SPEED: 170 (3 SEC. GUSTS) 5. BUILDING CLASSIFICATION TABLE 1-I. ASCE 7 _ TE FBC TABLE 1604.5 6. WIND EXPOSURE CLASSIFICATION: D ADJUSTMENT FACTOR FOR EXPOSURE E HEIGHT: 1.47 7. COMPONENTS S CLADDING WIND PRESSURE ON ROOF ZONE 1 -38.2 ZONE 253,9 ZONE 3 -85.0 8. COMPONENTS E CLADDING WIND PRESSURE ON WALL ZONE 4 SEE 5 PLANS PSF 9. COMPONENTS e CLADDING WIND PRESSURE ON OVERHEAD GARAGE DOOR SEE PLANS PSF 10. LOADS: FLOOR 40 PSF ROOF/DEAD: 25 ePSF ROOF/LIVE 30 PSF II. SHEAR WALLS CONSIDERED FOR STRUCTURE? YES X NQ____.jIF NO, ATTACH EXPLANATION) 12. CONTINUOUS LOAD PATH PROVIDED? YES-X -NO (IF NO, ATTACH EXPLANATION) 13. ARE C OMPONANT AND CLADDING DETAILS PROVIDED? YES X NQ._(IF NO, ATTACH EXPLANATION) 14. MINIMUM SOIL BEARING PRESSURE: 2500 PRESUMPTIVE: 2500 BY TEST:, N/A _ PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED 'WITH THIS CERTIFICATIOM IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME: JOINN H. CRESWELL, PE DESIGN FIRM: SLCCDV FORMU 020-00 REVISED 5/18/09 (CL) CERT#: PE:s 40940, COA# 27002. DATE: SEAL IR I LEFT FLORIDA DESIGN CRITERIA WULT) 170 MPH (3 SEC. GUSTS) V(ASD) 132 MPH (3 SEC. GUSTS) EXPOSURE D IMPORTANCE FACTOR I CATEGORY 11 INTERNAL PRESSURE COEFFICIENT +/-0.18 ROOF ZONE UP LIFT PRESSURES: ZONE 1 -38.2 PSF ZONE 2 -53.9 ZONE 3 -85.0 FOR ROOF PITCHS 2/12 THRU 6/12 COMPONENTS � CLADDING PQESSURES-EXPOSUQE "D" TAG POS.PPESSURE NEG.PQESSURE TAG END ZONE SQ.FT. 46-0 -49.8 -61.6 10 4-4.0 -47.9 G -57.5 20 41.2 -45.1 -51.9 50 39.2 -43.1 -47.9 100 34.3 -38.1 -1 J -38.1 500 I�GNT EXPOSURE "D" MULTIPLIER MEAN ROOF HEIGHT FACTOR LESS THAN 15' 1.47 ELEVATIONS 114" = 1'-0" FIN.FL. FRONT 5v-CRIMP METAL ROOF 12 zo PAVERS ,I. 2 FACI ACU AT FIN. FL. ELEV. AFE NAVD88 WADE 12194 LINTEL SCHEDULE N I GN-STPENGTN PQECAST AND PRESTRESSED LINTELS MANUFACTUQED BY CAST-Cf2ETE Ltt SAFE APPLIED SAFE APPLIED GRAVITY GRAVITY UPLIFT UPLIFT BEAM KEY LENGTH TYPE LOAD LOAD LOAD LOAD COMPOSITE LI 2-10" PRECAST 6113 < 800 4460 < 400 8F16-IB/IT L2 4'-0" PRECAST 6113 < 800 1 3079 < 400 1 8F16-IB/IT L3 5`-4" PRECAST 5365 < 800 1 2290 1 < 400 1 8F16-IB/IT I. ALL BOND BEAM REINFORCING SHALL BE CONTINUOUS / ROUND ENTIRE HOUSE PERIMETER INCLUDING CHANGES IN BEAM ELEVATION. ALL SPLICES TO BE A MINIMUM OF 48 BAR DIAMETERS 2. CONCRETE FOR COLUMNS AND BEAMS SHALL HAVE 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS 3. A SINGLE FILLED CELL IS REQUIRED AT EACH SIDE OF EACH OPENING AND AT 6 FEET ON CENTER 4. 4 INCH MINIMUM BEARING IS REQUIRED FOR ALL LINTELS WHEN FILLED. LENGTH = OPEN SPAN PLUS 8 INCHES R- TO yBE"'*'7--W `T`�4-S PS;- SE--E)ET-A]i---E3 OVV 1 i PROVIDE B. , . • RETURNS IN ALL UNIT BEDROOM LOAD CALCULATIONS RESIDENTIAL 200 AMP ELECT. PANEL 240- IC 3W CIRC, DESCRIPTION VOLT SIZE WATT SIZE 1,2 AC/AH 240 60 12,000 6 3A WTR, HTR. 240 30 3,500 10 5,6 OVEN/RANGE 240 50 12,000 6 7,8 DRYER 240 30 1,000 10 9 LIVING RM. 120 15 1,500 14 10 MASTER BEDRM, 120 15 1,000 14 II OTHER BEDROOMS 120 15 1,000 14 12 DINING RM. 120 20 1,000 12 13 LAUNDRY/WASHER 120 20 1,000 12 14 KITCHEN 120 20 2,000 GFI 15 GARAGE 120 20 1,000 GFI 16 BATHROOMS 120 20 1,000 GFI 17 SPARE 120 20 1,000 12 FIRST 10,000 = 10,000 REMAIN. 29,000 AT 40% - 11,600 39,000 WATTS TOTAL 21,600 AMPS = 21,600/240 = 90 AMPS USE 150 AMP. SERVICE ELECT121CAL LEGEND 1/2 ON SWITCH 110 V. RECEPTACLE 110 V. REC-EPTACLE 220 V. SPr':CIAL PURPOSE OUTLET B FLOOR 0 TLET 0 PENDANi i.IGHT WALL M(A NT LIGHT FIXTURE IIOV FOR F=IXTURELITE.ETCJ RECESSF-r? LIGHT EXHAUST FAN/LITE COMBINTION ® EXHAUST FAN CEILING FAN CEILING FAN W/ LIGHT S SINGLE I'QLE SWITCH S3 DOUBLE !'(3LE SWITCH [=H 220 V. DIS,;OM�ECT ® SMOKE DETECTOR ® CARBON MONOXIDE ALARM FLOOD LIGHT DOOR OPENIE�R ® FLUORESt„ENT LIGHT FLUORESk:;EM LIGHT ® ELECTRIC'AL PANEL ELE-CTRIC.'.AL METER TELEVISION JACK (CABLE) PHONE-IA(,,K 0 DOORBE.a /GARAGE DOOR BUTTON CHIMES ® SPEAKEut GFI GROUND FAULT INTEZaPT WP WATERPROOF METER! FIELD I ELECTRICAL NOTES *200 AMP SERVICE *SMOKE DETECTORS AS k:)EQUIRED *CARBON MONOXIDE DETECTORS AS REQUIRED *FIELD VERIFY RECEPTACLE LOCATIONS *ALL BRANCH CIRCUITS THAT SUPPLY 120V. (A)SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, CAR SIMILAR ROOMS AND AREAS SHALL BE: PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.120)) (B)TAMPER RESISTANT RECEPTACLES (NEC 406.11) ARE REQUIRED IN DWELLING UNITS IN ALL AREAS AS SPECIFIED IN 2008 NEC 21C.52, ALL I25V. 15 AND 20 AMP RECEPTACLES *RECESSED LIGHTING FIXTURES MUST COMPLY WITH: FLORIDA ENERGY CODE 606.I.ABC. 1.2.4. PRODUCT APPROVAL (TOTALLY ENCLOSED) GFQ WP ELECTICAL PLAN 1 PER 2010 N.E.C. E_ U r �I \� 200 AMP, IPH., 31/V., 115/230V FLUSH MOUNTED NEMA 1 NCB- TO SCALE ®P W/200 AMP MAIN BREAKER PANEL (30 c1Rc.) FILL ANGLE CORNER SOLID W/3000 PSI CONC/ CONCRETE BLOCK EXT. WALLS WAI) #5 AT 6' O.C.VERT. E EA. SIDE OF: EA. OPENING AND ALL INSIDE E OUTSIDE CORNERS ELECTRIC METER BY F.P.L. (TRANSFORMER BY I`.P.-, IN 2' DIA. COND 200 AMP M/ 1.N DIS( 1M ZL_ AUTO DISONNI .CT FOR GENERATOR FIELD LO(-ATE 30AMP (3) u2/0 THHN-CU IN 2" CONDUIT u4 SO_.9D OR STRANDED CU. GROUNDED TO (2)u5 REINFORCING BARS AT FOUNDATION BASE 2 GRN1:I.20DS ® 6 APART U2/0 LIFER :QOLJND REQUIRED m FLOOQ PLAT\) I/4" = I'<)" CONCRETE BLOCK EXTERRI'DR WALLS WITH TYPICAL STUCCO I'll'JISH IO.OSEER ACU2 (MIN.) 5V-CRIMP METAL ROOF OVER 30tt FELT OVER 19/32" CDX PLYWOOD SEE ROOF NAILING ZONE AND ATTACHMENT DETAIL "SIMPSON' HETA20 AT EACH TRUSS TO BEAM W/(12) IOD X 1-1/2 SEE SOFFIT i FASCIA DETAIL 12 4 PITCH""" - ITCH ENGINEERED ROOF TRUSS AT 24' O.C. -30 INSULATION I'X4" AT BOTTOM CHORD AT 8" O.C. AND CONTINUOUS WXWAM AILED W/(3) 8D COMMON EA,TRUSS 1/2' DRYWALL CEILING CONCRETE "U' BLOCK 7/8' P.C. STUCCO W/(1) =5 CONTINUOUS TYPICAL EXTERIOR USE CONCRETE LINTEL ABOVE ALL WINDOWS AND DOORS TH12U BLOCK WALL CONCRETE BLOCK EXT. WALLS W14) #5 VERT. AT 4' O.C. E EA. SIDE OF EA. OPENING IN BLOCK WALL E ALL CORNERS AND CONT. FROM FOOTING TO BEAM VERT TO T.O.B. 1/2" DRYWALL OVER R-4.5 FOIL OVER I" X 2" P.T. FIR OVER CONC. BLOCK 4' CONC. 6A.F.E. NAVD88 CONCRETE FOOTING W(4)tt5'S CONT. (2) AT TOP AND (2) AT BOTTOM GRADE TED FILL b L'-6'J A TYPICAL WALL SECTION N.T.S. 2" vX LAV I u- - - 12" I M.BATH \1 I SHOWER — — —" ( j1l2" VTR 2" I 3" VTR 1 JIL I I 1 I BATH2/SH0 =-R 1 I LAV 2" 13" I 2) / /-u W/D 1 /1 / 3/ 2"� )zs. 3"� 3" 1 3 1 SINK 31 AUTO VENT " �-2"J KITCHEN I� V I I 3i PLUMBING 21SER N.T.S. i{ 4 4A/O TO APPROVED SEPTIC SYSTEM "SIMPSON" SP6 AT EA. STUD TO DBL, 2" X 6" P.T. TOP PLATE W/(6) TOP PLATE IOD X 1-1/2 STUCCO OVER PAPER BACKED WIRE LATH OVER 1/2" CDX PLY, OVER VAPOR WRAP -19 INSUL. OVER 2" X 6" WOOD FRAME AT 16' O.C. *SIMPSON' SPH6 AT EA. STUD TO BOTTOM PLATE 1/2" DRYWALL W/(6) IOD X I-I/2 INSIDE 1/2" DIA. WEDGE ANCHOR AT 32" O.C. 2" X 6" P.T. E6" FROM EA. END BOTTOM PLATE W/6" MIN. EMBEDIMENT ""'I ILANS AND ALL ARE SUBJECT TO ANY CORRECP0148 REQUIRED Y FIELD INp Y BE NEES ETRS x a PLY- ]' . h ayy 4'nA% Sc 1. yVR V a �a 16" X 16" CONC. FTNG. W/(2) tt5'S CONT. DETAIL AT STORAGE B N.T.S. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD P * 4"CONC.SLAB W/6' X 6"-IOjO W.W.M. OVER 6 MIL. VISQUEEN OR EQUAL OVER CLEAN COMPACTED NON ORGANIC FILL TO 95% DENSITY • SOIL BELOW SLAB TO BE TERMITE TREATED PRIOR TO SLAB POUR • 250OPSI MIN CONIC W/VAPOR BARRIER • ALL FOOTING DESIGN BASED ON 2500(ASSUMED) PSF SOIL BEARING CAPACITY, CONTRACTOR TO VERIFY, PROVIDE MIN. 3/4" RECE3� AND/OR SILL FOR ALL DOORS TO EXTERIOR.(INCL. GARAGE) FOUNDATION PLAN 114" = 1'-0" CONCRETE BLOCK e-XTERIOR WALLS WITH TYPICAL STUGCO FINISH BEARING (HEADER SCHEDULE SIZE SPECIES NAILING OPENING JACKS FLJLL STUD (2)2X6 SPF STAGGERED UP TO 3'-II (1) (I) 12"OC 16D (2)2X8 HEMP FIR STAGGERED 4' TO 6' (1) (I) 12"OC 16D (2)2XIO HEMP FIR STAGGERED 6'-1 TO 8'-6 (2) (1) 12"OC 16D (2)2X12 HEMP FIR STAGGERED 8'-7 TO 16' (2) (2) 8"OC 16D NON -BEARING HEADER SCHEDULE SIZE SPECIES NAILING OPENING JACKS FULL STUD (2)2X4 SPF STAGGERED UP TO 3'-II (1) (1) 12"OC 16D (2)2X6 SPF STAGGERED 4' TO 9'-8 (1) (1) 12"OC 16D • - I' MIN' FROM EDGE 412" HEADER 2"MAX 1 12" MAX PLYWOOD PLYWOOD -CRIMP METAL OF PANEL CRIMP METAL DF PANEL FELT I. AT THE SAVE, RAKEAND RIDGE, FASTENERS SHALL BE LOCATED NOT MORE THAN 3" AWAY FROM THE PANEL END. 2. THE LEADING SIDE EDGE OF THE PANEL SHOULD BE THE SIDE WITH THE ANTI -SIPHON GROOVE, EACH PANEL SIDE WILL OVERLAP THIS CHANNEL TO PROVIDE A CAPILLARY BRAKE. 3. tt9-15 X 1-1/2" SELF DRILLING CORROSIAN RESISTANT FASTENERS W/ SELF SEALING WASHERS AT 12" O.C. AND AT 12" O.C. IN THE ENTER OF THE PANEL AT THE FIELD PERPENDICULAR TO THE ROOF SLOPE ON THE HIGH POINTS OF THE PANEL RIBS.4. THE PANEL'S WIDTH FASTENERS SHALL BE SPACED AT 12" O.C. TO THE CENTER RIB, THEN 12" TO THE NE-.T, PERPENDICULAR TO THE SLOPE, THROUGH THE OVERLAPPING PANEL, THE FLAT AREA OF THE PANEL AS SHOWN IN THE DETAILS HEREIN. 5. THE PANELS FASTENING PATTERN AT THE INTERIOR OF THE PANEL, SHALL BE IN ROWS SPACED 12" O.C, RUNNING PARALLEL TO THE SLOPE OF THE ROOF. FL tt6931-12I FILLED BLK. FOII I"X2" P.T DRYWALL_ I/` FIR STRIP 2"X8" P.T. DOOR BUCK ATTACHED W/1/4" X 4" TAPCONSm6" EA,END. E oI8" O.C(SNGL.LEAF) E e12" O.C. (DBL.LEAF) _ BRICK MOULDING HINGED SWING DOOR JAMB ATTACHED W/tt10 X 3" WOOD SCREWS ®6" EA.END i IS" O.C.(SNGL,LEAF) E 12" O.C,(DBL.LEAF) EXTERIOR SWING DOOR ATTACHMENT DETAIL 3/8' COPJT. BEAD OF CAULK SACK BEDDING) BEHIND BUCK TO PREVENT LIQUID PASSAGE SET FLANGE IN CONT, BED OF CAULK ACROSS ENTIRE FACE OF BUCK PERIMETER ATTACH P.T, BUCKS W/,099 X 1-1/2' NAILS AT 12' O.C. /4' MAX SHIM P.T. IX WOOD BUCK TO ND BEYOND INTERIOR FACE OF WINDOW OR S.G.D. /T DRYWALL ATTACH AS PER MANUF. PRODUCT APPROVALS TYP. ALUM.WINDOW OR S.G.D. JAMB 1"X2' P.T. I"X2" P.T. FURRING FURRING 1/2" DRYWALL I"X6" P.T. WINDOW BUCK ATTACHED W/1-112" "T" NAILS e 18"O.C. VE12T jC i� ' i' : • WINDOW FRAME ATTACHED TO CONC, BLOCK THRU WOOD TYPICALJ WINDOW BUCK W/1/4" X 2-I, STUCCO TAPCONS, FILL ALL HOLES WINDQW ATTACHMENT MIN, EMBED 1-1/4" DETAIL. 3/8' CONT. BEAD OF CAULK (LACK BEDDING) BEHIND SHIM (_LACK O PREVENT LIQUID PASSAGE 1/4' (MAX) SHIM SP T FLANGE IN CONT, BED OF CAULK ACROSS. ENTIRE FACE OF SHIM PERIMETER CAULK - CORROSIVE RESISTANT "TAPCON' CONC. SCREWS INSTALLED AS SPECIFIED SILL IN WINDOW MANUF. PRODUCT APPROVAL CONC.BLK.EXT. WALL W/Iv5 VERT AS IN FLOOR PLAN TYPICAL_ WINDOW E S.G.D. JAMB DETAIL AT C.B.S. WALL TYPICAL PRECAST-CONC. SILL DETAIL NOTE GUNNABLE SEALANTS SHALL COMPLY WITH ASTM C 920 CLASS 25 GRADE N5 NOTE! GUNNABLE SEALANTS SHALL COMPLY WITH ASTM C 920 CLASS 25 GRADE N5 OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION R703.8 FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS, SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1, EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING OR 0`fHER APPROVED METHOD 1.1 THE FENESTRATION MANUFACTURER'S WRITTEN FLASHING INSTRUCTIONS. 1.2 THE FLASHING MANUFACTURER'S WRITTE-N INSTALLATION INSTRUCTIONS. 1.3 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, OR FMA/WDMA 250. 1.4 IN ACCORDANCE WITH THE FLASHING METHOD OF A REGISTERED DESIGN PROFESSIONAL. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. S. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. ATTACHMENT TO ALUMINUM DECK AS PER AC MANUF, CONDENSER UNIT ALUMINUM AC PLATFORM, SEE DETAIL THIS PAGE EXTERIOR WALL COMPRESSOR ATTACHMENT DETAIL N.T.S. SEE ALL PAGES FOR STRUCTURAL DETAILS PNEUMATIC F,-\STNER SCHEDULE 1) PNEUMATIC FASTNERS SHALL BE "HILTI" COIL NAI'I-S, TYPE CRF 1120, 1-1/2" LONG BY ,120 DIAMETER UNLESS OTHERWISE NOTED. 2,) FASTNERS OF EQUAL LENGTH AND DIAMETER MAY BE SUBSTII UTED FOR THOSE SPECIFIED, LOCATION NAIL SIZE MANUF. MODEL tt SPACING/ REMARKS PLYWOOD WALL 2-3/8" X ,113 (34 DEG.) PRUDENTIAL SHEATHING Bid -DING MAT, SP8RMS SEE DIAPHRAM SCHEDULE PLYWOOD FLOOR 2-3/8" X ,113 (34 DEG.) PRIDENTIAI SHEATHING BJLDING MAT. SPBRMS SEE DIAPHRAM SCHEDULE PLYWOOD ROOF 8D COMMON COATED PZ-0ENTIAL SHEATHING BU'LDING MAT, SEE DIAPHRAM SCHEDULE I" X 2' FURRING .099 X 1-1/2" SM NTERNATIONAL 422428 16" O.C. STRIPS STAPLE WINDOW BUCKS .12C X 1-1/2" HILTI 12" O.C. "vAKAVC LJUUK 1/2" X 5-1/2' RAMSET/REDHEAD 24" O,C, VERTICALLY BUCKS DOOR BUCKS 1/4" X 2-1/2' NTERNATIONAL 8" O.C. TAPCONS STAPLE SLIDING GLASS 120 X II-1/2" HILTI 12" O.C. DOOR BUCKS KUUI•- BASE 120 X II" CENCO HJI5A7A 12" O.C. AT HEAD LAPS AND EVE EDGES SHEET GALVANIZED 24" O.C. AT EDGE OF VALLEY SHEETS DIAPHRAM SCHEDULE PANEL FRAMING DIAPHRAM ZONE I ZONE 2 ZONE 3 EDGE INTER, EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING BOUNDERIES REMARKS ROOF APA RATED SHEATHING EXPOSURE I, OR EQUAL 19/32" 24" O.C. MAX. IOD, 6" O.C. ICED, 6" O.C. IOD' 6" O.C. IOD, 6" O.C. IOD, 6" O.C. IOD, 4" O.C. IOD, 4" O.C. BLOCKING AS SHOWN SPAN RATING 40/20 NOTE: ALL ROOFING NAILS TO BE RING SHANK NOTE TO GENERAL CONTRACTOR ALL CONNECTIONS IN CONTACT WITH ACQ MATERIAL SHALL BE HOT DIPPED GALVANIZED MINIMUM. NOTE TO BUILDER, BUILDER SHALL COORDINATE AND REVIEW ALL FINAL ARCHITECTURAL DRAWINGS WITH TRUSS MANUFACTURERS DRAWINGS BEFORE TRUSS MANUFACTURERS TRUSS ENGINEERING PACKAGES AND ACTUAL TRUSSES ARE PRODUCED. (2) 5/8" D. WEDGE ANCHOR MOUNTING PLATE TO BLK. WALL BOTH SIDES 1/4" X 4" ALUM MOUNTING PLATE W/I/4" FILET WELDS ALL EDGES 1/4" X 3" FLAT STRAP, BOTH SIDES OF PLATFORM Sc')" X 36"X 1/4" ALUM. AC — PLATFORM 14" FILET WELD 5/8" D. WEDGE ALL EDGES ANCHOR AT 6" O.C. PLATFyORM TO BLK.WALL TYPICAL FOOTING TYPICAL EXTERIOR WALL ALUMINUM AC MOUNTING PLATFORM AT FINISHED FLOOR ELEVATION AL DRIP FLASHING '." P.T. DRIP EDGE i" PRIMED R.S. CIA TYPICAL WALL CONTRACTOR TO USE SEE WALL DETAILS 7/8" STUCCO OVER 3/8" HI RIBBED PAPER BACKED METAL LATH OVER "TYVEK" W/1" PER F,B.C. 2514.3.5, THE CONTRACTOR SHALL SOFFIT E FACIA DETAIL INSTALL 6' X 24" SOFFIT VENTS ® 8'-O" O.C. N.T.S. 6' A.F.E. NAVD88 Y CEILING OR WOOD CONT. 25 GAUGE METAL STUDS AT 0 TRACKS TOP E BOTTOM 24" O.C. 25 GAUGE CHANNEL SHAPED STUDS AT 24" O.C. W/ 1/2' GYPSUM WALL BOARD APPLIED VERTICALLY E ATTACHED W/ I" LONG BUGLE HEAD SCREWS TO EA. SIDE AT 12' O.C. CONIC, FLOOR SLAB TYPICAL INTERIOR PARTITION N.T,S, X 4" TOP PLATE 2" X 4" WOOD STUDS AT 24" O.C. WITH 1/2" DRYWALL BOTH SIDES ATTACH 2" X 4" .BOTTOM PLATE TO FL. JOISTS WITH t*10 X 4" WOOD SCREWS AT 4" FROM EA. END 24" O,C., (3) MIN, LOOP JOIST KNEEWALL DETAIL 0 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILI IY OF THE CONTRACTOR OF RECORD NON BEARING INTERIOR WALLS TRUSS❑ HEEL 3 15/16" T PLUMB[] CANTILEVER TRUSS❑ HEEL 3 15/16 T PL..UMB❑ CANTILEVER TYPICAL❑ ROOF DETAIL❑ ALL FLAT CEILIN 12 4F HANGER SCHEDULE:❑ HUS26 QTY = 211 El HIPCATS (4/12) QTY = 4 1' —� 2 12 GS 4' 0 5/8" B3G 77 2' 2 9/16" 3' 11 1 /2" 2-PLY BEAM BY BUILDER❑ TOENAIL BC TO BEAM 2L 12 *BUILDER'S WARNING* THIS IS A PLACEMENT PLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1-1995. DIAPHRAGMS HAVE NOT BEEN ANALYZED BY EAST COAST TRUSS. FOR ERECTION AND INSTALLATION OF TRUSSES FOLLOW INSTRUCTIONS ON THE BCSI—B1 SUMMARY SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS �c BRACING 1.) FOR ERECTION BRACING FOLLOW INSTRUCTIONS ON THE BCSI--B1 SUMMARY SHEETS. 2.) PERMANENT BRACING FOR THE STRUCTURE IS THE RESPONSIBILITY OF OTHERS. 3.) INSTALL WEB BRACING AS STATED ON SEALED ENGINEERED TRUSS DRAWINGS. * SEE FINAL ENGINEERING SHEETS FOR THE STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS PLIES AND THE CONNECTION INFORMATION. OUR DESIGN DEPARTMENT MUST APPROVE ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ADVANCE. �c BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR DESIGN DEPARTMENT APPROVES THEM IN ADVANCE. ALL HANGERS ARE SIMPSON STRONG —TIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG —TIE CATALOG. 12 TRUSS❑ ` HEEL. 3 15/16" ZERO❑ LOT LINE TRUSS❑ HEEL 3 15/ 16'° 0°�► PLUMB❑ CANTILEVER BRG POINT TRUSS CONNECTOR SCHEDULE residence TRUSS CONNECTOR CONNECTOR CONNECTOR (TRUSS I.D.I UPLIFT I MFG I QTY I TO USE CONI I UPLIFT I FASTENERS PER STRAP I I i I I I I I I I Truss to Concrete < 1725 S 1 H ETA20 I I I I I 1805 I 1 10-10d x 1-1/2 Truss to Wood I i< 625 1 U 1 1 I R17A I I_ I 1 650 ( 10-8d x 1-1 /2 Connector Mfg U==USP, S=Simpson SIGNATURE ACKNOWLEDGES: Having used the Truss Loads (Provided by the Truss Manufacturer) for Design of Pertinent Components. No Responsibility is Hereby Assumed for the Dimensioning, Detailing, Fabrication Nor Installation of This Truss System. APPROVED BY: J0NN N. C2FSDVVELL) PE TITLE: ENGINEER OF RECORD APPQOVAL DATE: CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED F OR ARE SUBJECT TO ANY ORREOT$ IDS REQUIRED BY FIELD INSPECT . 8 THAT R 'NECESSARY IN ORDER TO COMPIX WIT114 ALL APPLICABLE ABI E COOES, ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS ECT EAST COAST TRUSS 5285 ST. LUCIE BLVD. FT. PIERCE FL. 34946 OFFICE: (772)466-2480 FAX: (772)466-5336 CUSTOMER: MEL-RY JOB NAME: EAMES RES. ADDRESS: 992 NETTLES BLVD. CITY/COUNTY: JENSEN BCH/ST. LUCIE CNN JOB#: 25641 MODEL: CUSTOM DATE: 08/22/ 13 In accordance with the Florida Administrative Code 61 G15S-31.003 (3) (c), EAST COAST TRUSS is the "Truss Design Engineer". Trusses are designed in accordance with the Florida Building Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representative acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that: this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated oil this drawing. The customer acknowledges that he/she accepts financial responsible for any repair engineering and labor required due to errors other than those of EAST COAST TRUSS signed date CODE: FBC 2010/TP12007 ASCE 7-10 DESIGN CRITERIA - MAIN WIND FORCE OCCUPANCY CATEGORY: II EXPOSURE CATEGORY = D MWF SPEED: 170 M.P.H. BUILDINE TYPE: ENCLOSED MEAN HEIGHT: 16'-0" TRUSS SPACING 24" O.C. EXCEPT AS NOTED GRAVITY LOADS ROOF TC LIVE: 20psf TC DEAD: 15psf BC LIVE: 10psf* BC DEAD: 10psf DUR FACTOR: 1.25 LOADS PER FBC & FRC * NON -CONCURRENT BC LL 1 Opsf CONCURRENT BC STORAGE LL 20psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS & CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DAL = DEAD LOAD DL = DEAD LOAD # =POUNDS psf = POUNDS PER SQUARE FOOT CAUTION: SPANS GREATER THAN 30'-0" MUST BE SET WITH A SPREADER BAR. THE SPREADER BAR SHOULD BE AT LEAST 1 /2 TO 2/3 IN LENGTH AS THE SPAN OF THE TRUSS BEING SET. REFER TO BCSI-131 FOR COMPLETE ERECTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER NOTE: TRUSSES DO NOT SUPPORT ANY PLANT SHELVES (1 /4" if plotted 1 8x24 DESIGNED BY: YKW J < z LL_ Ln w Z Cn W 07 00 L.J Cn O F_ y— O N N F E W 00 0 It C 0 0