Loading...
HomeMy WebLinkAboutTruss Placement Plan*BUILDER"S WARNING* *WA�tNING* ALL BEARING POINTS MUST BE INSTALLED PRIOR TO INSTALLING ANY TRUSSES' FAIL' )RE TO DO SO MAY RESULT IN DAMAGED TRUSSES AND WILL VOID ALL WARANTIES. " THIS IS A PLACEMENT PLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1 - 1995. DIAPHRAMS HAVE NOT BEEN ANALYZED BY EAST COAST TRUSS. * FOR ERECTION AND INSTALLATION OF TRUSSES FOLLOW INSTRUCTIONS ON THE BCSI-131 SUMMARY SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS *BRACING: 1) FOR THE ERECTION BRACING FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS 2) PERMANENT BRACING FOR;, THE STRUCTURE IS THE RESPONSIBILITY OF OTHERS. 3) INSTALL WEB BRACING AS STATED ON SEALED ENGINEERING TRUSS DRAWINGS. " SEE FINAL ENGINEERING SHEETS FOR THE STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS PLIES AND THE CONNECTION INFORMATION. * OUR DESIGN DEPARTMENT MUST APPROVE ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ADVANCE. * BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR DESIGN DEPARTMENT APPROVES THEM IN ADVANCE ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG -TIE CATALOG MOM r- M b) It nAr Gn TRUSS PLACEMENT PLAN NON BEARING INTERIOR WALLS ------------------- ---------------.--- F-l" PLATE HIT. � 1 211 811 PLUMB CANTILEVER TRUSS HEEL 3 15/1611 a _._.. 1211 811 PLUMB CANTILEVER HANGER SCHEDULE: HUS26 QTY = 2 HIPCATS (4/12) QTY = 4 TYPICAL ROOF DETAIL ALL FLAT CEILINGS 12 4 .. 12 412_ 4' 0 5/8" B3G 2.83r— 2 /16" 3T1 /8 3' 11 1 /2A 2-PLY BEAM BY BUILDER TOENAIL SC TO BEAM ( /, TRUSS'�N HEEL 3 15/16" 1 C °° 8" 0" PLUMB CANTILEVER ZERO LOT LINE 4__ 0 IT-1 - Pr3rou;-T5 EAST COAST TR tJSa, O 5285 ST. LIE L'LVD. FT. IEP.0 � c L P F FL. 3�J46 OFFICE: (7 2)d66-2,180 FLY: (779)166-5336 (� /1 CUSTOMER: Mel-Ry Construction JOB NAME: Eames Res. ADDRESS: 992 Nettles Blvd. Nettles Island CITY/CNTY: Jensen Bch/St, Lucie JOB # 25641 DATE: 08/22/13 IN ACCORDANCE WITH THE FLORIDA ADMINISTRATIVE CODE 61G15S-31.003 (3) (c), EAST COAST TRUSS is the "Truss Design Engineer" Trusses are designed in accordance with the Florida A Building Code i i APPROVAL NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his represehtitive acknowledges that this placement plan 1 1 1 complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST j COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. 1 The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and labor required due to errors i other than those of EAST COAST TRUSS. Signed: J Date: Q Z LL- CODE= FBC 2010/TP12007 ASCE 7-10 DESIGN CRITERIA = MWFRS 0 OCCUPANCY CATEGORY = II EXPOSURE = D W MWF SPEED = 170 BUILDING TYPE = ENCLOSED Q MEAN HEIGHT = 15'-0" � GRAVITY ROOF: DUR FACTOR= 1.25 PSF=TCLL - TCDL - BCLL - BCDL J 20-15-10*-10 Z U) LOADS PER FBC & FRC *1-COfCU�BLI— C, 10psf CONCURRENT BC STORAGE ILL 20 PSf CAUTION: SPANS GREATER THAN D 30'-0" MUST BE SET WITH A SPREADER BAR. THE SPREADER BAR SHOULD BE AT LEAST 1/2 TO I-- 2/3 IN LENGTH AS THE uPAN OF W THE TRUSS BEING SET. (0 REFER TO BCI-B1 FOR COMPLETE ERECTION AND SAFETY W PROCEDURES. W D E-- O Z ALL BEAMS BY BUILDER 0 NOTE: TRUSSES DO NOT SUPPORT ANY PLANT SHELVES 0 REVISIONS )ATE BY 4- 0