Loading...
HomeMy WebLinkAboutCertificate For Design Load ComplianceI Planning & Development Services Department • Building & Code Regulations Division 111111111111110 - — 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 7 Certification for Design Load Compliance Project Name: f2cAnc'4+ i. Project Address: L o r 410 ® Ve � �-m, y 4kAv, e�- Permit #: Occupancy Type: Construction Type:y INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS ILSEDi (complete all that apply) 1. DESIGN CODE: Florida Z O lq Code 2010 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: _I YII 111 IV Exposure Category: B D 4. Design Wind Velocity 1&6 mph LSD _,,�S_LRFD End Zone Width: 5. Mean Roof Height IT, a" ft Roof Pitch: 5 :12 Parapet: f�k ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH,.dearly label on all plan openings): Zone 1• No. L Zone'2: 70. V Zone 3: ?0 6 Zone 4: N$.! Zone 5: .3 Garage: NN, c. 7. Design Loads: Floor: (15 PSF Roof/Dead: _PSF Roof/Uve: 3o Balcony: 60 PSF Dock: N A PSF Deck: &5 PSF Stairs: 10 PSF Fence: �% PSF Railings: _PSF 8. Were Shear Walls Considered For Structure? ZC Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? _Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: L,50 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL cERTIFic&WN STATEMENT: 1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. 1 also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 3-50 Print A/Name Cert #& Co. Cert Auth. (X-- V'%4o-► C-Aaii%lt r:A3 As d ci RL STa c . ado AL 4 sh. 240 Signature, D e,anaSeal 'tal, 6-crJCA1 F- 3TIf$ Company Name & Address Revised 07/25/2014 ?A